17.04.2015 Views

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

Summary Report for Conduct of Kozloduy NPP Stress Tests

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

“<strong>Kozloduy</strong> <strong>NPP</strong>” PLC<br />

SUMMARY REPORT<br />

<strong>for</strong> <strong>Conduct</strong> <strong>of</strong> <strong>Kozloduy</strong> <strong>NPP</strong><br />

<strong>Stress</strong> <strong>Tests</strong><br />

availability <strong>of</strong> the siphons at elevation <strong>of</strong> -4.50 = 31,10m). Pumps <strong>of</strong> ASSGEM system are located<br />

at elevation <strong>of</strong> -3.00 m which determines that they will be affected at MWL more than +32,50 m.<br />

The only scenario is isolation <strong>of</strong> water supply systems „Zhelezni vrata” 1 and 2 as a result <strong>of</strong><br />

the earthquake. however in this case the effect <strong>of</strong> MWL will be executed at sufficiently later phase<br />

<strong>of</strong> accident progress process (about 20 hours after the earthquake).<br />

In accordance with results <strong>of</strong> assessment <strong>of</strong> the margins at extreme meteorological<br />

conditions it is defined that due to closed and self-contained nature <strong>of</strong> the spent fuel storage system,<br />

SFP 3 and 4 and their auxiliary systems there is a high safety level in relation to external factor<br />

„Extreme winds and tornados”.<br />

6.1.3.2.3 Unavailability <strong>of</strong> the power supply<br />

In accordance with results <strong>of</strong> assessment <strong>of</strong> margins to loss <strong>of</strong> electric power and loss <strong>of</strong><br />

ultimate heat sink, it is defined that power supply to these systems <strong>for</strong> cooling <strong>of</strong> the fuel in SFP-3<br />

and SFP-4 is provided from various physically separated sources (emergency diesel generators –<br />

three per unit, emergency diesel-generators <strong>of</strong> ASSGEM, mobile DG). At low value <strong>of</strong> decay heat<br />

<strong>of</strong> the fuel stored in the pools. Available time margin be<strong>for</strong>e the assemblies uncoverage starts is<br />

about one week <strong>for</strong> SFP-3 and more than 9 days <strong>for</strong> SFP-4 at assumption <strong>of</strong> complete loss <strong>of</strong><br />

cooling.<br />

6.1.3.2.4 Potential failure <strong>of</strong> measurement instrumentation<br />

Within short-term modernization program <strong>of</strong> the units analysis was done <strong>for</strong> definition <strong>of</strong><br />

environmental parameters <strong>for</strong> equipment qualification at emergency conditions. As the first step <strong>of</strong><br />

the qualification the sensors <strong>of</strong> emergency protection chains were replaced with qualified sensors <strong>of</strong><br />

Emergency protection chains. For some the sensors related to safety, new location was selected, and<br />

they were moved to area which does not require qualification on extreme environmental conditions.<br />

As a result, at present all the measurement channels, related to reactor protection are<br />

qualified <strong>for</strong> correspondent seismic and environmental conditions. For conditioning <strong>of</strong> process<br />

parameter signals, precise digital equipment is used. Uninterrupted power supply units (UPS)<br />

additionally isolate power supply to these channels, by which independence is assured <strong>for</strong> the power<br />

supply to the channels.<br />

In addition to that the qualification program is executed <strong>for</strong> the remaining equipment related<br />

to safety, including test <strong>of</strong> samples <strong>of</strong> equipment <strong>for</strong> ageing, seismic and environmental conditions<br />

at loss-<strong>of</strong>-coolant accident. On the basis <strong>of</strong> results <strong>of</strong> the qualification program the remaining<br />

safety-related sensors were also replaced.<br />

To support Operator actions additional set <strong>of</strong> the computerized systems was implemented,<br />

such as:<br />

· Computerized system <strong>for</strong> supporting the operator and recording the process<br />

parameters at normal operations and in case <strong>of</strong> accident;<br />

181/202

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!