1020<br />
1030<br />
24" HEMLOCK<br />
12'-0"<br />
10'-0"<br />
4' WIDE GRASS STRIP<br />
100' +/-<br />
1000<br />
30' ACCESS EASEMENT<br />
38" FIR<br />
30" FIR<br />
980<br />
PROPOSED PERVIOUS PAVEMENT DRIVEWAY<br />
10'-0" INT SIDE S.B.<br />
970<br />
15' BSBL<br />
ORDINARY<br />
HIGH WATER 1-2<br />
ORDINARY<br />
HIGH WATER 1-1<br />
65'\PBUFFER<br />
S89°23'56"E<br />
665.04'<br />
960<br />
40" MAPLE<br />
10'-0"<br />
R 40'-0"<br />
R 33'-3 1/8"<br />
S E 4 8 t h S t r e e t<br />
30'-0"<br />
SETBACK<br />
@ ROAD<br />
S89°23'56"E BASIS OF BEARING<br />
2660.38'<br />
PROJECT DIRECTORY<br />
OWNERS:<br />
BRIAN AND CARI ABRAMSON<br />
9700 24th AVENUE NW<br />
SEATTLE, WA 98117<br />
ph. 206 . 790 . 2852<br />
PROJECT ADDRESS:<br />
TO BE DETERMINED<br />
ARCHITECT:<br />
GEOFF BELAU<br />
silo ARCHITECTURE + DESIGN<br />
1807 NW DOCK PLACE<br />
SEATTLE, WA 98107<br />
ph. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
STRUCTURAL ENGINEER:<br />
DIBBLE ENGINEERS, INC.<br />
25 CENTRAL WAY, SUITE 210<br />
KIRKLAND, WA 98033<br />
ph. 425 . 883 . 1900<br />
fax 425 . 497 . 1921<br />
CONTRACTOR:<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
consultants:<br />
970<br />
RESERVE<br />
DRAINFIELD<br />
WETLAND BOUNDARY<br />
1050<br />
1040<br />
S00°18'21"W<br />
298.91'<br />
1036'<br />
1036'<br />
40' +/-<br />
1034'<br />
1034'<br />
30' +<br />
36' +<br />
"GRASS-PAVE" @<br />
PARKING AREAS<br />
(PERMEABLE)<br />
32" CEDAR<br />
10'-0" INT SIDE S.B.<br />
10'-0" INT SIDE S.B.<br />
ATTACHED GARAGE:<br />
2 CAR CAPACITY<br />
56'-0" 10'-0"<br />
TREES TO BE<br />
REMOVED<br />
42'-0"<br />
parking elev.<br />
1033' +/-<br />
13'-8 1/2"<br />
16'-0"<br />
36'-0"<br />
85' +/-<br />
1040<br />
10'-0"<br />
30" CEDAR<br />
48" STUMP<br />
DECK ABV.<br />
PORCH @ GRADE<br />
24" CEDAR<br />
30" CED<br />
9'-6"<br />
44'-0"<br />
40" CEDAR<br />
40" CEDAR<br />
40'-0" 8'-0"<br />
109' +/-<br />
DECK<br />
40" CED<br />
40" CED<br />
40" CEDAR<br />
40" CEDAR<br />
(to be removed)<br />
89'-5 1/2"<br />
40" CEDAR<br />
17'-0"<br />
DRAINFIELD<br />
40" CEDAR<br />
1030<br />
34' +/-<br />
38" COTTONWOOD<br />
BSBL<br />
1020<br />
15'-0" BUFFER SETBACK (BSBL)<br />
1000 GAL SEPTIC TANK<br />
1250 GAL PUMP CHAMBER<br />
BUFFER<br />
1000<br />
1010<br />
110' WETLAND BUFFER<br />
POTENTIAL STORM WATER<br />
INFILTRATION AREA<br />
990<br />
PROPOSED NEW SFR<br />
3750 SF HEATED SPACE<br />
517 SF UNHEATED SPACE<br />
825 SF ATTACHED GARAGE (UNHEATED)<br />
188 SF DETACHED STORAGE SHED (UNHEATED)<br />
ELEVATION OF LOWEST FLOOR LEVEL<br />
1022'<br />
IMPERVIOUS SURFACE CALCULATION<br />
STRUCTURES (ROOFS, PATIOS, ETC.) = 4271 SF<br />
GRAVEL DRIVEWAY, PARKING, ETC. = 4823 SF<br />
TOTAL IMPERVIOUS SURFACE = 9094 SF (4.6 % OF LOT AREA)<br />
664.52'<br />
S89°19'22"E<br />
980<br />
S. A. S. A.<br />
BUFFER<br />
BSBL<br />
UN-IMPROVED ACCESS EASEMENT<br />
299.79'<br />
N00°24'20"E<br />
R 35'-0"<br />
DRAWING INDEX<br />
A0.1 SITE PLAN, PROJECT NOTES<br />
A0.2 SURVEY<br />
A1.1 BASEMENT FLOOR PLAN<br />
A1.2 FIRST FLOOR PLAN<br />
A1.3 SECOND FLOOR PLAN<br />
A1.4 ROOF PLAN<br />
A2.1 EXTERIOR ELEVATIONS (NORTH / EAST)<br />
A2.2 EXTERIOR ELEVATIONS (SOUTH / WEST)<br />
A3.1 BUILDING SECTIONS<br />
A3.2 BUILDING SECTIONS<br />
A3.3 BUILDING SECTIONS<br />
A4.1 WALL SECTIONS<br />
A5.1 WINDOW AND EXT. DOOR SCHEDULES<br />
S1.0 STRUCTURAL NOTES<br />
S2.0 GENERAL STRUCTURAL DETAILS<br />
S2.1 GENERAL STRUCTURAL DETAILS<br />
S3.0 FOUNDATION PLANS<br />
S3.1 FOUNDATION DETAILS<br />
S4.0 MAIN LEVEL FLOOR FRAMING PLANS<br />
S4.1 FLOOR FRAMING DETAILS<br />
S4.2 GENERAL FRAMING DETAILS<br />
S5.0 UPPER BDRM FLOOR FRAMING PLANS<br />
S6.0 MAIN ROOF FRAMING PLANS<br />
S7.0 UPPER ROOF FRAMING PLANS (GARAGE)<br />
S7.1 ROOF FRAMING DETAILS<br />
F A L L C I T Y H O U S E<br />
SITE PLAN<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
1<br />
A0.2<br />
SITE PLAN<br />
Scale: 1" = 30 ft<br />
date:<br />
GENERAL NOTES<br />
ROOF VENTILATION<br />
PROJECT INFORMATION<br />
PROJECT INFORMATION (cont.)<br />
1. ALL WORK SHALL CONFORM TO THE 2003 IBC AND/OR IRC AS MODIFIED BY LOCAL JURISDICTIONS<br />
AND ALL OTHER APPLICABLE GOVERNING LAWS, CODES, ORDINANCES, AND REGULATIONS.<br />
2. DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED DIMENSIONS ONLY.<br />
NOTIFY THE ARCHITECT IMMEDIATELY IF ANY CONFLICTS EXIST.<br />
ALL DIMENSIONS ARE TO FACE OF FRAMING AND CONCRETE WALLS UNLESS NOTED OTHERWISE.<br />
3. CONTRACTOR SHALL VERIFY ALL CONDITIONS PRIOR TO INITIATING THE WORK.<br />
NOTIFY THE ARCHITECT OF ANY DISCREPENCIES.<br />
4. VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT.<br />
PROVIDE ALL BULK-OUT, BLOCKING, BACKING, AND JACKS REQUIRED FOR INSTALLATION.<br />
5. VERIFY LOCATIONS OF ALL EXISTING UTILITIES AND SLEEVING.<br />
CAP, MARK, AND PROTECT AS NECESSARY TO COMPLETE THE WORK.<br />
6. PROVIDE FIREBLOCKING, DRAFTSTOPS, AND FIRESTOPS PER IBC/IRC AT ALL NEW CONSTRUCTION.<br />
7. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED PER IBC/IRC.<br />
ALL WOOD FRAMING AND SHEATHING AT INTERIOR WALLS TO BE FIRE RESISTANT.<br />
8. SERVICE WATER PIPES IN UNHEATED SPACES TO BE INSULATED.<br />
9. ENVELOPE OPENINGS TO BE CAULKED, SEALED, AND/OR WEATHERSTRIPPED.<br />
10. TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH WITH TAPE.<br />
USE SHEET PLASTIC VAPOR BARRIERS AT BATHROOMS.<br />
11. TAPE JOINTS AND INSULATE AT ALL METAL DUCTS.<br />
12. ALL NEW EXTERIOR WALL FRAMING TO BE 5 1/2" WOOD STUDS OR AS INDICATED IN THE DRAWINGS.<br />
ALL INTERIOR WALL FRAMING TO BE 3 1/2" WOOD STUDS OR AS INDICATED IN THE DRAWINGS.<br />
PLUMBING WALLS TO BE 5 1/2" STUDS, U.N.O.<br />
13. VENTILATE ROOF PER IBC/IRC.<br />
14. EGRESS WINDOWS SHALL BE PROVIDED AT ALL SLEEPING ROOMS PER IBC/IRC.<br />
15. TYPICAL NEW GLAZING TO BE THERMAL GLAZED, CLASS 40 OR BETTER.<br />
WINDOWS WITHIN 18" OF FLOOR OR ADJACENT TO DOORWAYS SHALL BE COMPRISED OF SAFETY OR<br />
TEMPERED GLASS.<br />
16. MAXIMUM 4" OPENINGS @ GUARDRAILS AND HANDRAILS.<br />
GUARDRAIL AND HANDRAIL HEIGHT TO BE 36" PER IBC/IRC, UNLESS NOTED OTHERWISE.<br />
17. ROOF DRAINS AND FOOTING DRAINS TIGHTLINE SEPERATELY TO EXISTING OR APPROVED DISCHARGE.<br />
18. MOISTURE CONTROL PER IBC/IRC.<br />
19. MOUNT ALL DOOR HARDWARE HANDSETS AT 36" TO CENTERLINE UNLESS NOTED OTHERWISE.<br />
20. PROVIDE SMOKE DETECTORS IN ALL SLEEPING ROOMS AND AS REQUIRED BY IBC/IRC.<br />
21. ALL SHOWERHEADS TO HAVE A MAXIMUM FLOW RATE OF 3.0 GALLONS PER MINUTE.<br />
22. SWITCHED OUTLETS: SWITCH TOP OUTLET OF DUPLEX OR AS SPECIFIED ON ELECTRICAL PLAN<br />
23. PROVIDE GFCI OUTLETS AND SWITCHES AS REQUIRED PER CODE.<br />
24. VERIFY LOCATIONS OF ALL ELECTRICAL OUTLETS, SWITCHES, AND DEVICES WITH OWNER PRIOR TO ROUGH-IN.<br />
25. CONTRACTOR TO SCHEDULE AND COORDINATE ALL REGULAR AND SPECIAL INSPECTIONS REQUIRED BY<br />
THE BUILDING PERMIT.<br />
26. CONTRACTOR SHALL OBTAIN ANY PERMITS REQUIRED TO WORK WITHIN THE PUBLIC RIGHT OF WAY<br />
27. CONTRACTOR SHALL MAINTAIN A COPY OF THE APPROVED PLANS ON SITE WHENEVER CONSTRUCTION<br />
WORK IS IN PROGRESS.<br />
28. IN THE EVENT OF SEDIMENT BEING TRACKED ONTO OFF-SITE STREETS OR ALLEYS, CONTRACTOR SHALL BE<br />
RESPONSIBLE FOR CLEANING THE AFFECTED AREAS. MAINTAIN, CLEAN, AND CLEAR ALL STORMWATER<br />
INLETS AND CATCH BASINS IN ADJACENT STREETS AND ALLEYS FROM ANY SITE GENERATED DEBRIS.<br />
PROVIDE VENTING EACH BAY @ EAVES, TYP. VENT OPENINGS TO BE PROTECTED w/<br />
CORROSION-RESISTANT WIRE MESH PER IRC R806. PROVIDE WARM SIDE VAPOR BARRIER AND 1SF NET<br />
FREE CROSS VENTILATION FOR EVERY 300 SF OF HTD ROOF AREA PER IRC R806. HOLD ROOF INSULATION<br />
BACK 1" FROM ROOF SHEATHING TO ALLOW FREE FLOW OF AIR THROUGH VENTS PER IRC R806.<br />
WHOLE HOUSE VENTILATION NOTES<br />
PROVIDE HEAT RECOVERY VENTILATOR UNIT FOR WHOLE HOUSE VENTILATION PER 2003 WA STATE VIAQ<br />
VENT TO HAVE FLOW RATING OF 105CFM (MIN) - 158CFM (MAX) PER VIAQ 303.4.1.1 AND TABLE 3-2.<br />
(CALCULATED FOR A 4 BEDROOM HOUSE WITH 3501SF-4000SF HABITABLE FLOOR AREA).<br />
VENT TO HAVE SONE RATING OF 1.5 OR LESS PER VIAQ 303.4.1.2.<br />
PROVIDE CONTROLS AND LABEL PER VIAQ 303.4.1.3.<br />
PROVIDE EXHAUST DUCTS PER VIAQ 303.4.1.4.<br />
PROVIDE OUTDOOR AIR INLETS PER VIAQ 303.4.1.5.<br />
ENERGY CODE NOTES<br />
(PER 2003 WASHINGTON STATE ENERGY CODE)<br />
PERSCRIPTIVE REQUIREMENTS FOR CLIMATE ZONE 1<br />
OPTION IV, UNLIMITED GROUP R-3<br />
GLAZING U-FACTOR: VERTICAL - 0.40 (AREA-WEIGHTED AVERAGE)<br />
OVERHEAD - 0.58 (N/A)<br />
DOORS U-FACTOR:<br />
INSULATION:<br />
APPLICABLE CODES<br />
0.20 (AREA WEIGHTED AVERAGE)<br />
CEILING w/ ATTIC CRAWL SPACE: R-38 MIN.<br />
VAULTED CEILING: R-30 MIN.<br />
WALL ABOVE GRADE: R-21 MIN.<br />
WALL BELOW GRADE (INTERIOR): R-21 MIN.<br />
WALL BELOW GRADE (EXTERIOR): R-10 MIN.<br />
FLOOR OVER CRAWL SPACE: R-30 MIN.<br />
SLAB ON GRADE: R-10 MIN.<br />
2003 INTERNATIONAL RESIDENTIAL CODE<br />
2004 WASHINGTON STATE ENERGY CODE<br />
2001 WASHINGTON STATE VENTILATION AND AIR QUALITY CODE<br />
2003 INTERNATIONAL MECHANICAL CODE<br />
2004 INTERNATIONAL FIRE CODE<br />
KING COUNTY CODE<br />
PROJECT DESCRIPTION<br />
CONSTRUCT NEW SFR w/ ATTACHED GARAGE AND DETACHED STORAGE SHED<br />
PROJECT ADDRESS<br />
SE 48th STREET (FALL CITY) - ADDRESSING TO BE DETERMINED<br />
TAX PARCEL NUMBER<br />
2124079079<br />
LEGAL DESCRIPTION<br />
LOT SIZE<br />
4.57 ACRES<br />
199,069 SF<br />
ZONING<br />
RA-10<br />
OCCUPANCY GROUP<br />
R-3 (SFR), U (ATTACHED GARAGE)<br />
CRITICAL AREAS<br />
WETLAND<br />
SHORELINE<br />
NO<br />
REQUIRED SETBACKS<br />
30' MIN. STREET SETBACK<br />
10' MIN. INTERIOR SETBACKS<br />
15' SETBACK FROM WETLAND BUFFER (BSBL)<br />
BASE HEIGHT LIMIT<br />
40' PER KC DEVELOPMENT STANDARDS 21A.12.030<br />
PROPOSED BLDG HEIGHT<br />
< 40'<br />
OFF-STREET PARKING SPACES REQUIRED<br />
2 SPACES PER NEW SFR<br />
PROPOSED NEW OFF-STREET PARKING SPACES<br />
2 COVERED SPACES (GARAGE), + ADDITIONAL OFF-STREET PARKING SPACES<br />
LOT COVERAGE ALLOWED<br />
LOT COVERAGE PROPOSED<br />
PROPOSED IMPERVIOUS SURFACE<br />
STRUCTURES (ROOF AREA, PATIOS, ETC) = 4271 SF<br />
GRAVEL DRIVEWAY, PARKING, ETC = 4823 SF<br />
TOTAL PROPOSED IMPERVIOUS SURFACE = 9,094 SF (4.6% OF LOT AREA)<br />
CONSTRUCTION TYPE<br />
VB (NON RATED)<br />
SPRINKLERS<br />
REQUIRED<br />
SYSTEM TO BE DESIGNED BY INSTALLER PER KING COUNTY FIRE MARSHALL<br />
FIRE SEPERATIONS<br />
1 HR ASSEMBLY BETWEEN ATTACHED GARAGE (U) AND SFR (R-3)<br />
1 HR ASSEMBLY BETWEEN BASEMENT MECHANICAL ROOM AND HABITABLE SPACE<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
7973<br />
scale:<br />
1" = 30'<br />
sheet:<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
A0.1
2<br />
A3.1<br />
2<br />
A2.1<br />
1<br />
A3.2<br />
1<br />
A3.1<br />
2<br />
A3.2<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
40'-0" 4'-0" 7'-5 1/2"<br />
38'-0"<br />
LINE OF DECK, ABOVE<br />
consultants:<br />
10'-6 3/4"<br />
8'-2"<br />
9'-8 1/2"<br />
5 1/2"<br />
5 1/2"<br />
6'-9"<br />
9'-6" 9'-6" 9'-6" 9'-6"<br />
CONC. SLAB<br />
12'-2"<br />
PATIO<br />
001a<br />
1/2" TYPE X GWB (MIN) ON<br />
MECH. SIDE OF<br />
WALLS AJOINING<br />
HABITABLE SPACE, TYP.<br />
5/8" TYPE X GWB @<br />
CEILING BELOW<br />
HABITABLE SPACE<br />
TAPE ALL SEAMS, TYP.<br />
7'-0"<br />
5 1/2" 5 1/2"<br />
CL WDW<br />
1'-10"<br />
008B<br />
5 1/2"<br />
1<br />
A2.1<br />
20'-0"<br />
10'-10 1/2"<br />
8'-8"<br />
2'-6 1/2"<br />
5 1/2"<br />
REC ROOM / MEDIA ROOM<br />
001<br />
LINE OF FLOOR HT<br />
CHANGE ABOVE<br />
SD<br />
001A<br />
CONC. FLOOR THROUGHOUT BASEMENT<br />
WINE CELLAR<br />
003<br />
(UNHEATED)<br />
CRAWL SPACE<br />
003A<br />
1/2" TYPE X GWB (MIN) ON WINE CELLAR SIDE OF<br />
WALLS AJOINING HABITABLE SPACE, TYP.<br />
5/8" TYPE X GWB @ CEILING BELOW HABITABLE SPACE<br />
TAPE ALL SEAMS, TYP.<br />
003B<br />
30"W x 48"H<br />
CRAWL SPACE<br />
ACCESS DOOR<br />
005A<br />
MECHANICAL RM<br />
005<br />
(UNHEATED)<br />
16'-0"<br />
F<br />
4'-0"<br />
50 CFM, MIN.<br />
POWDER RM<br />
004<br />
004A<br />
2'-6"<br />
8'-4 1/2"<br />
1'-6"<br />
2'-0"<br />
UP 10 R<br />
SD<br />
7'-11"<br />
CL WDW<br />
3'-2 1/4" 5 1/2" 3'-4 1/4"<br />
STORAGE<br />
007<br />
(UNHTD)<br />
UP 5 R<br />
007A<br />
5 1/2"<br />
008A<br />
5'-9"<br />
2'-8"<br />
STAIR AND HANDRAIL NOTES:<br />
BASEMENT / CRAWL SPACE / STORAGE<br />
008<br />
CONC. FLOOR THROUGHOUT BASEMENT / CRAWL SPACE / STORAGE<br />
STAIRS, HANDRAILS, AND GUARDRAILS TO CONFORM<br />
WITH ALL PROVISIONS OF THE 2003 IRC<br />
1. WIDTH OF STAIR: NOT LESS THAN 36" CLEAR<br />
2. 6'-8" MIN. FINISHED HEADROOM MEASURED<br />
FROM NOSING<br />
3. 7 3/4" MAX. RISER HEIGHT<br />
4. 10" MIN. TREAD DEPTH (NET)<br />
5. HANDRAIL TO BE PROVIDED AT LEAST ONE SIDE<br />
WHERE REQUIRED<br />
6. HANDRAIL HT NOT LESS THAN 34" OR MORE THAN<br />
38" AS MEASURED FROM TOP OF NOSING<br />
7. HANDRAIL(S) TO BE CONTINUOUS FOR FULL<br />
LENGTH OF RUN<br />
8. TERMINATE HANDRAIL ENDS AT WALL OR<br />
NEWELL POST<br />
9. REF. IRC R311.5.6.3 FOR ALLOWED HANDRAIL<br />
GRIP PROFILE DIMENSIONS.<br />
10. PROVIDE ADEQUATE LIGHTING AT ALL STAIR RUNS<br />
11. RAISED FLOORS OVER 30" HIGH SHALL HAVE<br />
GUARDRAILS NOT LESS THAN 36" IN HEIGHT<br />
12. OPENINGS IN GUARDRAILS OR OPEN STAIR RAILS<br />
SHALL BE LIMITED SO AS NOT TO ALLOW PASSAGE<br />
OF A 4" DIAMETER SPHERE (SEE IRC R312.2<br />
FOR EXCEPTIONS)<br />
1<br />
A3.3<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
BASEMENT<br />
FLOOR PLAN<br />
51'-11"<br />
date:<br />
LOCATION OF GARAGE, ABOVE<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
STRUCTURAL SUBMITTAL<br />
O2.15.07<br />
K.C. PERMIT SUBMITTAL<br />
stamp:<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
scale:<br />
1/4" = 1'-0"<br />
1<br />
A1.1<br />
BASEMENT AND BASEMENT / STORAGE / CRAWL SPACE FLOOR PLAN<br />
Scale: 1/4" = 1'-0"<br />
HEATED SPACE:<br />
UNHEATED SPACE:<br />
PATIO:<br />
472 SF<br />
517 SF<br />
400 SF<br />
LOCATION OF STORAGE SHED, ABOVE<br />
sheet:<br />
A1.1
s i l o<br />
ARCHITECTURE + DESIGN<br />
2<br />
A3.1<br />
1<br />
A3.2<br />
2<br />
A2.1<br />
1<br />
A3.1<br />
2<br />
A3.2<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
40'-0"<br />
11'-5 1/2"<br />
38'-0"<br />
6'-6 1/8"<br />
4'-0" 7'-5 1/2"<br />
7'-6" 14'-9 1/2" 15'-3"<br />
consultants:<br />
LINE OF DECK ABV<br />
5 1/2" 5 1/2" 7'-3"<br />
5 1/2"<br />
7'-8 1/2"<br />
DECK<br />
102a<br />
CL WDW<br />
CL WDW<br />
CL WDW<br />
5 1/2"<br />
10'-0"<br />
5 1/2"<br />
LINE OF ROOF ABV<br />
EGRESS<br />
EGRESS<br />
56'-0"<br />
20'-0"<br />
10'-11 1/2"<br />
5 1/2"<br />
VENT PER<br />
MECHANICAL CODE<br />
5 1/2"<br />
5 1/2"<br />
STORAGE<br />
113<br />
113A<br />
SD<br />
DASHED LINES INDICATE<br />
EXPOSED BEAMS ABV<br />
2x6 T&G WOOD FLOOR<br />
CONC. SLAB FLOOR<br />
LIVING RM / DINING RM<br />
102<br />
ZERO-CLEARANCE, DIRECT VENT<br />
GAS FIREPLACE INSERT.<br />
INSTALL PER MFGR'S SPECIFICATIONS<br />
AND ALL APPLICABLE CODES<br />
FLOOR BREAK LINE<br />
COUNTERTOP<br />
w/ SHELVES ABV<br />
DRY<br />
WOOD FLOOR THROUGHOUT<br />
LIVING AREA<br />
LAUNDRY<br />
111<br />
F<br />
50 CFM, MIN.<br />
WASH<br />
COUNTERTOP<br />
w/ SHELVES ABV<br />
KITCHEN ISLAND &<br />
EATING BAR<br />
CEILING BREAK LINE<br />
111A<br />
110B<br />
UP 1 R<br />
ENTRY / MUD RM<br />
110<br />
UP 3 R<br />
CEILING BREAK LINE<br />
9'-7" 4'-0"<br />
3'-6"<br />
TILE FLOOR @ ENTRY<br />
& LAUNDRY<br />
KITCHEN<br />
103<br />
4'-0"<br />
2'-0"<br />
110A<br />
3'-0"<br />
2'-0" 8" 2'-8" 7'-11 1/2"<br />
BOSCH<br />
D.W.<br />
BLUESTAR GAS<br />
OVEN & RANGE<br />
RANGE FAN<br />
100 CFM, MIN.<br />
CL WDW<br />
6'-0"<br />
SUBZERO 650<br />
REF/FRZR<br />
2'-0"<br />
F<br />
104A<br />
4'-0"<br />
PANTRY<br />
104<br />
101B<br />
SD<br />
COVERED ENTRY PATIO<br />
101a<br />
10'-0"<br />
LINE OF ROOF ABV<br />
COAT CLOSET<br />
1'-6"<br />
UP 10 R<br />
7'-0"<br />
DN 1 R<br />
DN 5 R<br />
3'-4 1/4" 3'-4 1/4"<br />
ENTRY / STAIRS<br />
101<br />
7'-11"<br />
DN 1 R<br />
5'-0" 11'-2 3/4" 7'-5 1/2"<br />
2 3/4"<br />
2'-0"<br />
6'-3"<br />
2'-8"<br />
101A<br />
F<br />
50 CFM, MIN.<br />
BATH<br />
107<br />
107A<br />
F<br />
50 CFM, MIN.<br />
POWDER<br />
106<br />
106A<br />
CONC. FLOOR<br />
10'-11 1/2"<br />
3'-8 1/2"<br />
HALL<br />
105<br />
BEDROOM<br />
108<br />
SD<br />
CL WDW<br />
CONC. FLOOR<br />
SD<br />
108A<br />
10'-11 1/2"<br />
108B<br />
2'-9 1/2"<br />
2'-9 1/2"<br />
SD<br />
109A<br />
3 1/2"<br />
109B<br />
3 1/2"<br />
3 1/2"<br />
ROCKERIES<br />
3'-3 1/2"<br />
8'-3 1/2" 3'-6"<br />
4'-3 1/2"<br />
CL WDW<br />
BEDROOM<br />
109<br />
CONC. FLOOR<br />
7'-8 1/2"<br />
CL WDW<br />
8'-0 1/2"<br />
17'-0"<br />
9'-6"<br />
EXST'G 40" CEDAR<br />
TO BE ROMOVED<br />
1<br />
A3.3<br />
1<br />
A2.2<br />
2<br />
A3.3<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
FIRST FLOOR PLAN<br />
LIVING / DINING / KITCHEN<br />
LOWER BEDROOMS<br />
GARAGE<br />
1<br />
A2.1<br />
5 1/2"<br />
5 1/2"<br />
11'-4 3/4" 8'-3 1/2" 3'-8 3/4"<br />
SD<br />
112B<br />
date:<br />
CONC. SLAB FLOOR<br />
UP 21 R<br />
STAIR AND HANDRAIL NOTES:<br />
SLOPE GARAGE SLAB TO DRAIN<br />
1/8" PER FOOT, TYP.<br />
GARAGE<br />
112<br />
1/2" TYPE X GWB (MIN) ON GARAGE SIDE OF<br />
WALLS AJOINING HABITABLE SPACE, TYP.<br />
5/8" TYPE X GWB @ CEILING BELOW<br />
HABITABLE SPACE<br />
TAPE ALL SEAMS, TYP.<br />
5 1/2"<br />
3'-2 1/2"<br />
DN 3 R<br />
5 1/2"<br />
10'-9 1/4"<br />
DN 3 R<br />
DN 3 R<br />
EXST'G 24" CEDAR<br />
TO BE REMOVED<br />
STAIRS, HANDRAILS, AND GUARDRAILS TO CONFORM<br />
WITH ALL PROVISIONS OF THE 2003 IRC<br />
1. WIDTH OF STAIR: NOT LESS THAN 36" CLEAR<br />
2. 6'-8" MIN. FINISHED HEADROOM MEASURED<br />
FROM NOSING<br />
3. 7 3/4" MAX. RISER HEIGHT<br />
4. 10" MIN. TREAD DEPTH (NET)<br />
5. HANDRAIL TO BE PROVIDED AT LEAST ONE SIDE<br />
WHERE REQUIRED<br />
6. HANDRAIL HT NOT LESS THAN 34" OR MORE THAN<br />
38" AS MEASURED FROM TOP OF NOSING<br />
7. HANDRAIL(S) TO BE CONTINUOUS FOR FULL<br />
LENGTH OF RUN<br />
8. TERMINATE HANDRAIL ENDS AT WALL OR<br />
NEWELL POST<br />
9. REF. IRC R311.5.6.3 FOR ALLOWED HANDRAIL<br />
GRIP PROFILE DIMENSIONS.<br />
10. PROVIDE ADEQUATE LIGHTING AT ALL STAIR RUNS<br />
11. RAISED FLOORS OVER 30" HIGH SHALL HAVE<br />
GUARDRAILS NOT LESS THAN 36" IN HEIGHT<br />
12. OPENINGS IN GUARDRAILS OR OPEN STAIR RAILS<br />
SHALL BE LIMITED SO AS NOT TO ALLOW PASSAGE<br />
OF A 4" DIAMETER SPHERE (SEE IRC R312.2<br />
FOR EXCEPTIONS)<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
7973<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
5 1/2"<br />
112A<br />
5 1/2" 5 1/2"<br />
DRAIN<br />
scale:<br />
1/4" = 1'-0"<br />
4'-0"<br />
18'-0"<br />
2<br />
A2.2<br />
STORAGE SHED<br />
114<br />
10'-0"<br />
sheet:<br />
28'-0"<br />
23'-11"<br />
37'-6 1/2"<br />
1<br />
A1.2<br />
FIRST FLOOR PLAN<br />
Scale: 1/4" = 1'-0"<br />
HEATED SPACE:<br />
UNHEATED SPACE (GARAGE):<br />
DECK:<br />
STORAGE SHED (UNHTD):<br />
1797 SF<br />
825 SF<br />
400 SF<br />
188 SF<br />
16'-0"<br />
A1.2
2<br />
A3.1<br />
1<br />
A3.2<br />
1<br />
A3.1<br />
2<br />
A2.1<br />
2<br />
A3.2<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
38'-0"<br />
7'-5 1/2"<br />
16'-2"<br />
6'-6"<br />
consultants:<br />
1'-9"<br />
5 1/2"<br />
DECK<br />
201a<br />
LINE OF ROOF ABOVE<br />
8'-6"<br />
5'-6"<br />
DECK BELOW<br />
5 1/2"<br />
SD<br />
201B<br />
EGRESS<br />
4'-0"<br />
WD FLOOR<br />
TILE FLOOR<br />
7'-0"<br />
3'-0"<br />
6'-2"<br />
3'-3 3/4"<br />
14'-0"<br />
6'-0"<br />
16'-7 1/2"<br />
28'-0"<br />
10'-2"<br />
5'-6"<br />
5 1/2"<br />
4'-0"<br />
DN 10 R<br />
SD<br />
201A<br />
WOOD FLOOR<br />
MASTER BEDROOM<br />
201<br />
18'-5 1/2"<br />
DASHED LINES INDICATE<br />
EXPOSED BEAMS ABV<br />
LINE OF ROOF ABOVE<br />
7'-11 1/2"<br />
3 1/2"<br />
CLG BREAK LINE<br />
CLOSET<br />
202<br />
WOOD FLOOR<br />
8'-0"<br />
4'-0"<br />
3 1/2"<br />
M. BATH<br />
203<br />
F<br />
50 CFM, MIN.<br />
10'-11 1/2"<br />
6'-6"<br />
5 1/2"<br />
3 1/2"<br />
3 1/2"<br />
5 1/2"<br />
6'-4"<br />
3'-0"<br />
17'-0"<br />
1<br />
A3.3<br />
1<br />
A2.2<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
8'-5 1/2"<br />
DECK<br />
206a<br />
1<br />
A2.1<br />
13'-4 3/4" 13'-4 3/4"<br />
2'-0" 4'-0" 3 1/2"<br />
4'-0"<br />
4'-6 1/2"<br />
LINE OF ROOF ABOVE<br />
206B<br />
EGRESS<br />
GUEST BEDROOM<br />
206<br />
SOFFITTED CLG<br />
IN BATHROOM<br />
OFFICE<br />
205<br />
WD FLOOR<br />
WD FLOOR<br />
207B<br />
206C<br />
DASHED LINES INDICATE<br />
EXPOSED BEAMS ABV<br />
BATH<br />
207<br />
TILE FLOOR<br />
SD<br />
206A<br />
205A<br />
F<br />
50 CFM, MIN.<br />
205B<br />
207A<br />
WD<br />
FLR<br />
HALL<br />
204<br />
SD<br />
STORAGE<br />
205a<br />
DN 21 R<br />
LINE OF ROOF ABOVE<br />
5 1/2" 3 1/2" 6'-2"<br />
3 1/2"<br />
2'-6" 5 1/2"<br />
5'-0"<br />
16'-1 1/2"<br />
5'-4 1/2"<br />
28'-0"<br />
STAIR AND HANDRAIL NOTES:<br />
STAIRS, HANDRAILS, AND GUARDRAILS TO CONFORM<br />
WITH ALL PROVISIONS OF THE 2003 IRC<br />
1. WIDTH OF STAIR: NOT LESS THAN 36" CLEAR<br />
2. 6'-8" MIN. FINISHED HEADROOM MEASURED<br />
FROM NOSING<br />
3. 7 3/4" MAX. RISER HEIGHT<br />
4. 10" MIN. TREAD DEPTH (NET)<br />
5. HANDRAIL TO BE PROVIDED AT LEAST ONE SIDE<br />
WHERE REQUIRED<br />
6. HANDRAIL HT NOT LESS THAN 34" OR MORE THAN<br />
38" AS MEASURED FROM TOP OF NOSING<br />
7. HANDRAIL(S) TO BE CONTINUOUS FOR FULL<br />
LENGTH OF RUN<br />
8. TERMINATE HANDRAIL ENDS AT WALL OR<br />
NEWELL POST<br />
9. REF. IRC R311.5.6.3 FOR ALLOWED HANDRAIL<br />
GRIP PROFILE DIMENSIONS.<br />
10. PROVIDE ADEQUATE LIGHTING AT ALL STAIR RUNS<br />
11. RAISED FLOORS OVER 30" HIGH SHALL HAVE<br />
GUARDRAILS NOT LESS THAN 36" IN HEIGHT<br />
12. OPENINGS IN GUARDRAILS OR OPEN STAIR RAILS<br />
SHALL BE LIMITED SO AS NOT TO ALLOW PASSAGE<br />
OF A 4" DIAMETER SPHERE (SEE IRC R312.2<br />
FOR EXCEPTIONS)<br />
2<br />
2<br />
A3.3<br />
SECOND FLOOR -<br />
FLOOR PLANS:<br />
MASTER BEDROOM<br />
OFFICE / GUEST RM<br />
date:<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
7973<br />
scale:<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
1/4" = 1'-0"<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
5 1/2" 2'-0" 4'-0" 4'-0" 3 1/2"<br />
5 1/2"<br />
A2.2<br />
sheet:<br />
19'-4"<br />
7'-5 1/2"<br />
1<br />
A1.3<br />
SECOND FLOOR PLANS<br />
Scale: 1/4" = 1'-0"<br />
HEATED SPACE (M. BDRM):<br />
HEATED SPACE (GUEST/OFFICE):<br />
TOTAL HEATED SPACE:<br />
DECKS:<br />
697 SF<br />
784 SF<br />
1481 SF<br />
152 SF<br />
A1.3
2<br />
A3.1<br />
51'-5 1/2"<br />
1<br />
A3.2<br />
2<br />
A2.1<br />
1<br />
A3.1<br />
42'-0"<br />
2<br />
A3.2<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
2'-0"<br />
2'-0"<br />
2'-0"<br />
consultants:<br />
4'-0"<br />
4'-0"<br />
1<br />
A2.1<br />
13'-6"<br />
2'-0"<br />
3'-0"<br />
7'-0"<br />
24'-0"<br />
1<br />
A3.3<br />
1<br />
A2.2<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
4'-0"<br />
ROOF PLAN<br />
2'-0"<br />
2<br />
25'-11"<br />
37'-6 1/2"<br />
A3.3<br />
date:<br />
36'-0"<br />
20'-6"<br />
3'-0"<br />
11'-0"<br />
1'-6"<br />
1'-6"<br />
1'-6"<br />
1'-6"<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07 STRUCTURAL SUBMITTAL<br />
O2.15.07 K.C. PERMIT SUBMITTAL<br />
stamp:<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
1'-6"<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
scale:<br />
4'-0"<br />
1/4" = 1'-0"<br />
2<br />
13'-0"<br />
sheet:<br />
2'-0"<br />
2'-0"<br />
A2.2<br />
32'-0"<br />
1<br />
A1.4<br />
ROOF PLAN<br />
Scale: 1/4" = 1'-0"<br />
1'-6"<br />
A1.4
s i l o<br />
ARCHITECTURE + DESIGN<br />
12<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
3<br />
consultants:<br />
DECK BEHIND PARAPET WALL<br />
N-06 N-07<br />
12<br />
3<br />
29'-2 1/8"<br />
CEDAR BOARD AND BATTEN SIDING<br />
HORIZONTAL "SHIPLAP" CEDAR SIDING<br />
ALUMINUM-CLAD WOOD WINDOWS, TYP.<br />
N-02a<br />
CEMENTITIOUS BOARD SIDING<br />
30'-3 5/8"<br />
METAL AND CABLE RAILING SYSTEM, TYP.<br />
3'-0" MIN.<br />
N-03<br />
N-04<br />
N-01<br />
2'-0" +/-<br />
N-02<br />
6'-5" +/-<br />
6'-0"+/-<br />
6'-0" +/-<br />
4'-0"<br />
4'-6" +/-<br />
4'-0"<br />
N-05<br />
2'-6"+/-<br />
3'-6"+/-<br />
4'-0"<br />
1<br />
A2.1<br />
4'-0"<br />
NORTH ELEVATION<br />
Scale: 1/4" = 1'-0"<br />
12'-0"<br />
1'-6" MIN.<br />
DASHED LINE INDICATES EXISTING GRADE<br />
LINE OF FINISHED GRADE<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
11'-0"<br />
9'-0"<br />
8'-0"<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
NORTH / EAST<br />
ELEVATIONS<br />
date:<br />
CEDAR BOARD AND BATTEN SIDING<br />
09.24.07 CONST. PROGRESS PRINTING<br />
CEMENTITIOUS BOARD INFILL PANELS<br />
E-07<br />
E-01<br />
O3.20.07<br />
O2.15.07<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
E-08<br />
E-06<br />
stamp:<br />
METAL AND CABLE RAILING SYSTEM, TYP.<br />
3'-0" MIN.<br />
CEM. BD.<br />
INFILL<br />
PANELS<br />
E-02<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
ALUMINUM-CLAD WOOD WINDOWS, TYP.<br />
E-05<br />
E-05<br />
E-04<br />
E-03<br />
3'-0" MIN.<br />
METAL AND CABLE RAILING SYSTEM, TYP.<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
scale:<br />
CEMENTITIOUS BOARD SIDING<br />
CEMENTITIOUS BOARD SIDING<br />
1/4" = 1'-0"<br />
sheet:<br />
E-02<br />
1'-6" MIN.<br />
A2.1<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
2<br />
A2.1<br />
EAST ELEVATION<br />
Scale: 1/4" = 1'-0"
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
consultants:<br />
12<br />
3<br />
MECHANICALLY HEMMED STANDING SEAM<br />
METAL ROOF, TYP.<br />
CEDAR BOARD AND BATTEN SIDING<br />
S-03<br />
CEMENTITIOUS BOARD INFILL PANELS<br />
CEMENTITIOUS BOARD SIDING<br />
1<br />
A2.2<br />
SOUTH ELEVATION<br />
Scale: 1/4" = 1'-0"<br />
CEMENTITIOUS BOARD SIDING<br />
S-01<br />
S-02<br />
S-04<br />
3'-0" MIN.<br />
3'-0" MIN.<br />
ALUMINUM-CLAD WOOD WINDOWS, TYP.<br />
METAL AND CABLE RAILING SYSTEM, TYP.<br />
LINE OF FINISHED GRADE<br />
DASHED LINE INDICATES EXISTING GRADE<br />
25'-4"<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
STEP FOUNDATION WALLS @ SLOPE AS REQ'D PER SITE CONDITIONS.<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
SOUTH / WEST<br />
ELEVATIONS<br />
EXPOSED GLULAM RAFTER-BEAMS -<br />
PROTECT ENDS w/ ZINC CAPS, TYP.<br />
date:<br />
09.24.07 CONST. PROGRESS PRINTING<br />
ALUMINUM-CLAD WOOD WINDOWS, TYP.<br />
W-06<br />
O3.20.07<br />
O2.15.07<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
HORIZONTAL "SHIPLAP" CEDAR SIDING<br />
MECHANICALLY HEMMED STANDING SEAM<br />
METAL ROOF, TYP.<br />
stamp:<br />
W-04<br />
12<br />
3<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
CEMENTITIOUS BOARD SIDING<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
CEMENTITIOUS BOARD SIDING<br />
W-02<br />
scale:<br />
1'-6" MIN.<br />
W-01<br />
W-02<br />
1/4" = 1'-0"<br />
sheet:<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
2<br />
A2.2<br />
WEST ELEVATION<br />
Scale: 1/4" = 1'-0"<br />
A2.2
12<br />
3<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
consultants:<br />
12<br />
3<br />
T.O. PLATE @ STAIR<br />
+ 15'-4 5/8" (1046.89')<br />
T.O. PLATE @ PANTRY/ATTIC (BEYOND)<br />
+ 14'-9 1/4" (1046.25')<br />
6'-0"<br />
1<br />
A3.1<br />
2'-0" +/-<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
SECTION<br />
Scale: 1/4" = 1'-0"<br />
20'-6"<br />
4'-0" +/-<br />
4'-0"<br />
3'-6" +/-<br />
4'-0"<br />
6'-0" +/-<br />
6'-0"<br />
8'-0"<br />
TO<br />
KITCHEN/<br />
DINING/<br />
LIVING RM<br />
TO<br />
WINE CELLAR<br />
and<br />
BASEMENT<br />
T.O. PLATE<br />
+ 10'-7 1/2" (1042.125')<br />
T.O. SUBFLR<br />
0'-0" (1031.5')<br />
ENTRY / STAIR<br />
101<br />
8'-1 1/8"<br />
9'-4 5/8"<br />
T.O. LANDING SUBFLR<br />
+ 6'-0" (1037.5')<br />
T.O. LANDING SUBFLR<br />
- 3'-10" (1027.67')<br />
T.O. BASEMENT SLAB<br />
- 9'-2 3/4" (1022.25')<br />
T.O. BASEMENT / STORAGE SLAB<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
T.O. PLATE<br />
12<br />
- 11'-11 1/2" (1019.5')<br />
+ 28'-3 7/8" (1059.82')<br />
3<br />
4'-0"<br />
14'-9 1/4"<br />
T.O. PLATE<br />
+ 21'-6 5/8" (1053')<br />
BUILDING<br />
SECTIONS<br />
4'-0"<br />
date:<br />
8'-0"<br />
DECK<br />
206a<br />
12<br />
T.O. OFFICE/GUEST SUBFLR<br />
+ 13'-6 5/8" (1045')<br />
OFFICE<br />
205<br />
GUEST ROOM<br />
206<br />
3<br />
4'-0"<br />
T.O. PLATE @ LIVING RM<br />
+ 15'-9 1/4" (1047.25')<br />
T.O. PLATE<br />
+ 11'-0" (1042.5')<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07 STRUCTURAL SUBMITTAL<br />
O2.15.07<br />
K.C. PERMIT SUBMITTAL<br />
10'-0"<br />
3'-6"<br />
stamp:<br />
T.O. GARAGE SLAB<br />
+ 2'-6" (1034')<br />
GARAGE<br />
112<br />
STORAGE<br />
113<br />
9'-0"<br />
LIVING / DINING<br />
102<br />
DECK<br />
102a<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
5'-0" +/-<br />
CRAWL SPACE<br />
T.O. LIVING RM SUBFLR<br />
+0'-0" (1031.5')<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
WINE CELLAR<br />
003<br />
PATIO<br />
001a<br />
scale:<br />
1/4" = 1'-0"<br />
2<br />
A3.1<br />
SECTION<br />
Scale: 1/4" = 1'-0"<br />
4'-0" +/-<br />
DAYLIGHT BASEMENT<br />
001<br />
T.O. BASEMENT SLAB<br />
- 9'-2 3/4" (1022.25')<br />
sheet:<br />
A3.1
s i l o<br />
ARCHITECTURE + DESIGN<br />
3<br />
12<br />
+ 28'-3 7/8" (1059.8')<br />
T.O. PLATE<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
4'-0"<br />
+15'-9 1/4" (1047.25')<br />
T.O. PLATE @ LIVING RM<br />
+0'-0" (1031.5')<br />
T.O. LIVING RM SUBFLR<br />
- 9'-2 3/4" (1022.25')<br />
T.O. BASEMENT SLAB<br />
FINISH GRADE @ SECTION CUT<br />
8'-0" TO TOP PLATE<br />
DECK<br />
102a<br />
4'-0"<br />
LINE OF STAIR WALL, BEYOND<br />
LINE OF PANTRY WALL, BEYOND<br />
STORAGE<br />
006<br />
12<br />
LIVING / DINING<br />
102<br />
8'-0"<br />
T.O. PLATE<br />
+11'-0" (1042.5')<br />
3<br />
9'-0"<br />
T.O. PLATE<br />
+21'-6 5/8" (1053')<br />
WINE CELLAR<br />
003<br />
3'-6"<br />
8'-4 1/2"<br />
4'-0"<br />
ENTRY / MUD RM<br />
110<br />
CRAWL SPACE<br />
4'-0" +/-<br />
1<br />
8'-0" TO TOP PLATE<br />
A3.2<br />
BATH<br />
207<br />
5'-0" +/-<br />
BUILDING SECTION<br />
Scale: 1/4" = 1'-0"<br />
HALL<br />
204<br />
GARAGE<br />
112<br />
T.O. SUBFLR<br />
+ 0'-7 1/2" (1032')<br />
STORAGE<br />
205a<br />
DIMENSIONS FOR STEPS IN FOUNDATION WALL ARE APPROXIMATE.<br />
APPROPRIATE ADJUSTMENTS TO BE MADE IN THE FIELD, IF REQUIRED<br />
BY SPECIFIC SITE CONDITIONS AFTER EXCAVATION.<br />
10'-0" TO TOP PLATE<br />
14'-9 1/4" TO TOP PLATE<br />
+ 13'-6 5/8" (1045')<br />
T.O. OFFICE/GUEST SUBFLR<br />
EXST'G GRADE @ SECTION CUT<br />
+ 2'-6" (1034')<br />
T.O. GARAGE SLAB<br />
ROCKERY OR GABION WALL<br />
1:1 SLOPE, MAX.<br />
FINISH GRADE @ SECTION CUT<br />
consultants:<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
EXST'G GRADE @ SECTION CUT<br />
BUILDING<br />
SECTIONS<br />
T.O. MASTER BEDROOM SUBFLR<br />
+ 17'-0 1/4" (1048.5')<br />
12<br />
3<br />
date:<br />
T.O. MASTER BEDROOM SUBFLR<br />
+ 6'-0" (1037.5')<br />
11'-0 1/4" TO TOP PLATE<br />
4'-0"<br />
M. BATH<br />
203<br />
7'-0" TO TOP PLATE<br />
3'-0"<br />
T.O. PLATE<br />
+ 13'-0" (1044.5')<br />
STORAGE SHED<br />
114<br />
EXST'G GRADE @ SECTION CUT<br />
FINISH GRADE @ SECTION CUT<br />
T.O. STORAGE SHED SLAB<br />
ROCKERY OR GABION WALL<br />
1:1 SLOPE, MAX.<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
+ 2'-6" (1034')<br />
8'-0" TO TOP PLATE<br />
GARAGE<br />
112<br />
BEDROOM<br />
109<br />
ROCKERY OR GABION WALL<br />
1:1 SLOPE, MAX.<br />
< 4'-0"<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
T.O. LOWER BEDROOM SUBFLR<br />
- 3'-2 3/4" (1028.25')<br />
scale:<br />
1/4" = 1'-0"<br />
sheet:<br />
T.O. BASEMENT/CRAWLSPACE SLAB<br />
- 11'-11 1/2" (1019.50')<br />
FINISH GRADE @ SECTION CUT<br />
2<br />
A3.2<br />
BUILDING SECTION<br />
Scale: 1/4" = 1'-0"<br />
A3.2<br />
EXST'G GRADE @ SECTION CUT
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
SOFFITTED CEILING<br />
consultants:<br />
ATTIC CRAWL SPACE<br />
EGRESS<br />
MASTER BEDROOM<br />
201<br />
CLOSET<br />
202<br />
M. BATH<br />
203<br />
UPPER LANDING<br />
T.O. MASTER BEDROOM SUBFLR<br />
LIVING RM / DINING RM<br />
102<br />
9'-0"<br />
KITCHEN<br />
103 PANTRY<br />
104<br />
+ 6'-0" (1037.5')<br />
T.O. LIVING RM SUBFLR<br />
+0'-0" (1031.5')<br />
T.O. BASEMENT FIN. SLAB<br />
- 9'-2 3/4" (1022.25')<br />
1<br />
A3.3<br />
DAYLIGHT BASEMENT<br />
001<br />
BUILDING SECTION<br />
Scale: 1/4" = 1'-0"<br />
STORAGE<br />
006<br />
T.O. LANDING SUBFLR<br />
- 3'-10" (1027.68')<br />
MECHANICAL RM<br />
005<br />
LOWER LANDING<br />
STORAGE<br />
007<br />
2'-8 3/4"<br />
POWDER<br />
106<br />
BASEMENT/CRAWL/STORAGE<br />
008<br />
BEDROOM<br />
108<br />
EGRESS<br />
BEDROOM<br />
109<br />
EGRESS<br />
T.O. LOWER BEDROOM FIN. SLAB<br />
- 3'-2 3/4" (1028.25')<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
BUILDING<br />
SECTIONS<br />
date:<br />
DECK<br />
206a<br />
09.24.07 CONST. PROGRESS PRINTING<br />
W-04 W-05 W-05<br />
O3.20.07<br />
O2.15.07<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
W-07<br />
stamp:<br />
T.O. GARAGE/STORAGE FIN. SLAB/FLR<br />
+ 2'-6" (1034')<br />
T.O. LAUNDRY/MUD SUBFLR<br />
STORAGE<br />
113<br />
LAUNDRY<br />
111<br />
ENTRY / MUD RM<br />
110<br />
W-02<br />
W-01<br />
W-02 W-03<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
+ 0'-7 1/2" (1032.125')<br />
CRAWL SPACE<br />
scale:<br />
1/4" = 1'-0"<br />
sheet:<br />
2<br />
A3.3<br />
BUILDING SECTION and WEST ELEVATION<br />
Scale: 1/4" = 1'-0"<br />
A3.3
FLASH'G<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
BLCK'G / FLSH'G @ STEP IN ROOFING<br />
TYPICAL ROOF COMPONENTS:<br />
- 22 GA STANDING SEAM METAL ROOFING, TYP.<br />
- 30# FELT UNDERLAYMENT<br />
- 1/2" PLYWD BACKING FOR ROOFING<br />
- 2x10 PURLINS @ 24" o.c., TYP., U.N.O. (REF. STRUCTURAL)<br />
- PERP. 2x BLOCKING @ 24" o.c. (ALLOW AIRSPACE)<br />
- 1" MIN. AIRSPACE ABOVE INSULATION<br />
- R-30 INSULATION, TYP.<br />
- 4-MIL VAPOR BARRIER<br />
- PLYWD. ROOF SHEATHING PER STRUCTURAL<br />
- T&G CAR DECKING PER STRUCTURAL<br />
- GLULAM RAFTER-BEAMS PER STRUCTURAL<br />
PROVIDE GALV. OR ZINC END CAP @ END OF GLBs, TYP.<br />
CONTINUOUS VENT w/ INSECT SCREEN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
consultants:<br />
ENTRY PORCH ROOF COMPONENTS:<br />
- 22 GA STANDING SEAM METAL ROOFING, TYP.<br />
- 30# FELT UNDERLAYMENT<br />
- T&G CAR DECKING PER STRUCTURAL<br />
- RAFTERS PER STRUCTURAL<br />
CONTINUOUS VENT w/ INSECT SCREEN<br />
BEAM PER STRUCTURAL<br />
MTL FLSH'G OVER EXT WDW &<br />
DOOR OPN'Gs, TYP.<br />
COLUMN TO BEAM CONNECTION<br />
PER STRUCTURAL<br />
GALVANIZED STEEL PIPE COLUMN<br />
PER STRUCTURAL<br />
ATTIC (OVER KITCHEN)<br />
CEILING COMPONENTS @ KITCHEN:<br />
- 5/8" GWB @ SOFFIT CEILING<br />
- 4 MIL VAPOR BARRIER<br />
- 2 x 10 SOFFIT FRAMING @ KITCHEN<br />
- INSULATE SOFFITTED CEILING TO EXTENT POSSIBLE<br />
- 3/4" T&G PLYWOOD SUBFLOOR<br />
KITCHEN<br />
103<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
TYPICAL WALL COMPONENTS:<br />
- CEDAR BOARD AND BATTEN OR SHIPLAP SIDING<br />
(HARDI-PANEL OR EQUAL @ SIM CONDITIONS)<br />
- 30# FELT UNDERLAYMENT<br />
- WALL SHEATHING PER STRUCTURAL<br />
- 2x6 STUDS @ 16" o.c., TYP., U.N.O. (REF. STRUCTURAL)<br />
- BLOCKING AND NAILING PER STRUCTURAL<br />
- R-21 INSULATION, TYP.<br />
- 4-MIL VAPOR BARRIER<br />
- 1/2" GWB, U.N.O.<br />
DECK<br />
102a<br />
DECK COMPONENTS:<br />
WALL<br />
SECTIONS<br />
COLUMN TO FOOTING CONNECTION<br />
PER STRUCTURAL<br />
- 2x6 CEDAR DECKING<br />
- 2x JOISTS PER STRUCTURAL<br />
date:<br />
FOOTING PER STRUCTURAL<br />
TYPICAL FLOOR COMPONENTS:<br />
- FINISH FLOOR (VARIES)<br />
- PLYWD SUBFLR PER STRUCTURAL<br />
- TJI FLOOR JOISTS PER STRUCTURAL<br />
- BLOCKING AND NAILING PER STRUCTURAL<br />
- R-30 INSULATION @ UN-HEATED BASEMENT CONDITION<br />
- 5/8" GWB, TYP., U.N.O.<br />
BASEMENT<br />
PROVIDE FLASH'G @ T.O. LEDGER<br />
HOLD DECK LEDGER OFF SHEATHING<br />
1/2" TO ALLOW FOR DRAINAGE<br />
BEAM PER STRUCTURAL<br />
COLUMN TO BEAM CONNECTION<br />
PER STRUCTURAL<br />
GALVANIZED STEEL PIPE COLUMN<br />
PER STRUCTURAL<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07 STRUCTURAL SUBMITTAL<br />
O2.15.07 K.C. PERMIT SUBMITTAL<br />
stamp:<br />
@ TALL FOUNDATION WALL CONDITION:<br />
- 1/2" AIRSPACE @ CONC.<br />
- 2x4 STUDS @ 24" o.c.<br />
- R-19 INSULATION<br />
- 4 MIL VAPOR BARRIER ON WARM SIDE<br />
- 1/2" GWB, TYP., U.N.O.<br />
TYPICAL INTERIOR SLAB COMPONENTS:<br />
- REINFORCED CONC. SLAB PER STRUCTURAL<br />
- HYDRONIC/RADIANT TUBES<br />
- RIGID INSULATION<br />
- VAPOR BARRIER<br />
- PEA GRAVEL<br />
- UNDISTURBED EARTH OR COMPACTED FILL<br />
COLUMN TO FOOTING CONNECTION<br />
PER STRUCTURAL<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
scale:<br />
3/4" = 1'-0"<br />
FOUNDATION WALLS, RETAINING WALLS, FOOTINGS, AND SLAB PER STRUCTURAL<br />
FOOTING AND SLAB<br />
PER STRUCTURAL<br />
sheet:<br />
A4.1
Window and Exterior Door Schedule<br />
I.D. Qty. Type Unit Size Frame Details Rough Opening<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
4'-0"<br />
5'-0"<br />
8'-0"<br />
N-02a<br />
3'-0"<br />
2"<br />
2'-11 1/2"<br />
4'-0"<br />
1'-11 1/2"<br />
2'-8"<br />
3'-0"<br />
6'-0"<br />
W H Sill Ht. Head Jamb Sill W H Sill Ht. Mfgr U-Value Materials, Features Notes<br />
N1 1 awning 4'0" 4'0" 3'0"
40'-0" 11'-5 1/2" 38'-0"<br />
11'-6"<br />
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
9'-6" 9'-6" 9'-6" 9'-6"<br />
4'-0" 7'-5 1/2"<br />
10'-6 3/4" 8'-2" 7'-9"<br />
4'-0"<br />
5<br />
10'-4"<br />
9'-10"<br />
HD11<br />
S3.1<br />
SLAB ON GRADE<br />
(SLOPE 1/4" PER FOOT)<br />
6'-9" 12'-2" 4'-11 1/4" 4'-8"<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
DOOR LOCATION<br />
CONC. FTG.<br />
6'-0" x 6'-4" x 12"<br />
w/ #4 @6" E.W.<br />
1'-0"<br />
2'-6 1/2"<br />
HD12<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
8<br />
S3.1<br />
7'-0"<br />
CONC. FTG.<br />
1'-4" x 8" w/ (2) #4<br />
HD12<br />
8<br />
S3.1<br />
HD12<br />
HD12<br />
HD12<br />
8<br />
S3.1<br />
HD11<br />
7<br />
S3.1<br />
CONTROL JOINTS<br />
HD12<br />
HD12<br />
consultants:<br />
Dibble Engineers, Inc.<br />
25 Central Way, Suite 210<br />
Kirkland, WA 98033<br />
Tel. 425 . 883 . 1900<br />
Fax 425 . 417 . 3735<br />
20'-0"<br />
8'-0"<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
STEP FOUNDATION WALL<br />
9'-0" VERIFY IN FIELD<br />
9<br />
S3.1<br />
STEP FOUNDATION WALL<br />
STEP FOUNDATION WALL<br />
2'-6" V.I.F.<br />
TYP.<br />
8<br />
S3.1<br />
HD12<br />
HD11<br />
CRAWL SPACE<br />
SLAB ON GRADE<br />
(-9'-2 3/4")<br />
HD11<br />
9<br />
S3.1<br />
2'-6"<br />
11<br />
S3.1<br />
HD12<br />
CONTROL JOINTS<br />
HD11<br />
DOOR<br />
LOCATION<br />
HD12<br />
DOOR<br />
LOCATION<br />
2'-10" 2'-7"<br />
HD12<br />
9<br />
S3.1<br />
HD12<br />
CONC. FTG.<br />
3'-0" x 2'-6" DEEP w/ (3) #5<br />
TOP & BOTTOM (3" CLR., TYP.)<br />
9<br />
S3.1<br />
4'-0"<br />
23'-11"<br />
1'-6"<br />
2'-0"<br />
10<br />
HD14<br />
HD13<br />
S3.1<br />
DOOR LOCATION<br />
6"<br />
HD11<br />
6'-3" 10"<br />
7'-11"<br />
11'-2 3/4" 7'-5 1/2"<br />
2 3/4"<br />
THICKENED SLAB<br />
1'-0" x 6" DEEP w/ (2) #4<br />
HD11<br />
9<br />
S3.1<br />
9'-6"<br />
4'-1"<br />
SLAB ON GRADE<br />
(-3'-2 3/4")<br />
HD11<br />
HD11<br />
37'-6 1/2"<br />
9<br />
S3.1<br />
HD13<br />
HD13<br />
7<br />
S3.1<br />
TYP.<br />
17'-0"<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
BASEMENT /<br />
FOUNDATION<br />
PLAN<br />
HD12<br />
1'-2 1/2"<br />
2'-10"<br />
STEP FOUNDATION WALL<br />
28'-0"<br />
14'-0" 14'-0"<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
CONC. FTG.<br />
2'-9" x 2'-9" x 10" DEEP<br />
w/ (4) #4 EACH WAY<br />
HD12<br />
6<br />
S3.1<br />
HD12<br />
SLAB ON GRADE<br />
(+2'-6" - SLOPE 1/4" PER FOOT TO DRAIN)<br />
CONTROL JOINTS<br />
CONC. FTG.<br />
2'-9" x 2'-9" x 10" DEEP<br />
w/ (4) #4 EACH WAY<br />
8'-6 1/4"<br />
3'-10 3/4"<br />
HD12<br />
HD12<br />
THICKENED SLAB<br />
1'-0" x 6" w/ (2) #4<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
1<br />
S3.0<br />
FOUNDATION PLAN<br />
Scale: 1/4" = 1'-0"<br />
date:<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
7973<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
REGISTERED<br />
ARCHITECT<br />
6<br />
S3.1<br />
10'-0"<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
UPPER / STUDIO<br />
HD11<br />
HD11<br />
GARAGE DOOR LOCATION<br />
4<br />
S3.1<br />
HD11<br />
HD12<br />
CONC. FTG.<br />
1'-0" x 6" w/ (2) #4<br />
UPPER / BDRM<br />
MAIN<br />
LOWER BDRM<br />
BASEMENT<br />
BSMT / CRAWL<br />
GARAGE<br />
scale:<br />
1/4" = 1'-0"<br />
sheet:<br />
3'-11"<br />
18'-2"<br />
FLOOR LEVEL KEY<br />
NTS<br />
S3.0<br />
28'-0"
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
CMSTC16<br />
PONY WALL TOP PLATE TO<br />
STORAGE RM BOTTOM PLATE<br />
CS14 STRAP @<br />
END JST TO RIM<br />
4x6 HDR<br />
6x6<br />
SW1<br />
(2) 2x6 FH<br />
14" TJI 230 @ 12" o.c.<br />
4x6 BRG<br />
P.T. 6x10, TYP.<br />
3<br />
S4.1<br />
5 1/8 x 12 GLB<br />
P.T. 2x10s @ 16" o.c.<br />
HD3 (2) 2x6 FH<br />
4x6 BRG<br />
SW1<br />
14" TJI 230 @ 16" o.c.<br />
14" TJI 230 @ 12" o.c.<br />
WELD CCO TO PIPE<br />
HD3<br />
5 1/2" DIA. PIPE, TYP.<br />
HD3<br />
SW1<br />
HD3<br />
F<br />
2<br />
S4.1<br />
50 CFM, MIN.<br />
9<br />
S4.1<br />
CS14 STRAP @<br />
END JST TO RIM<br />
HD3<br />
HD3<br />
SW3<br />
SW2<br />
6x6 HDR<br />
1 3/4 x 14 LSL<br />
4x6 HDR<br />
1 3/4 x 14 LSL<br />
3 1/4 x 14 LSL<br />
HD7<br />
SW1<br />
LANDING<br />
LANDING<br />
NOTES:<br />
HD1<br />
3 1/8 x 10 1/2 GLB 24F-V4<br />
14" TJI 230 @ 16" o.c.<br />
1. CS16 STRAP REQ'D AS FOLLOWS, U.N.O.:<br />
a. TOTAL LENGTH = 3 FT.<br />
b. CENTER @ JOINT<br />
c. FILL EVERY HOLE w/ 8d<br />
2. CS14 STRAP REQ'D AS FOLLOWS, U.N.O.:<br />
a. TOTAL LENGTH = 3'-6"<br />
b. CENTER @ JOINT<br />
c. FILL EVERY HOLE w/ 10d<br />
3. CMSTC16 STRAP REQ'D AS FOLLOWS, U.N.O.:<br />
a. TOTAL LENGTH = 8'-0"<br />
b. CENTER @ JOINT<br />
c. (33) 16d EACH HALF OF STRAP ((66) 16d TOTAL)<br />
HD1<br />
SW1<br />
HD1<br />
6x6 HDR<br />
HD1<br />
SW1<br />
HD3<br />
SW2<br />
SW2<br />
consultants:<br />
Dibble Engineers, Inc.<br />
25 Central Way, Suite 210<br />
Kirkland, WA 98033<br />
Tel. 425 . 883 . 1900<br />
Fax 425 . 417 . 3735<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
MAIN LEVEL<br />
FLOOR FRAMING<br />
PLAN<br />
date:<br />
SEE SHEET S1.2 FOR SECOND FLOOR FRAMING<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
STRUCTURAL SUBMITTAL<br />
1<br />
S4.0<br />
MAIN LEVEL AND LOWER BEDROOM FLOOR FRAMING PLAN<br />
Scale: 1/4" = 1'-0"<br />
O2.15.07<br />
stamp:<br />
K.C. PERMIT SUBMITTAL<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
UPPER / STUDIO<br />
UPPER / BDRM<br />
MAIN<br />
LOWER BDRM<br />
GARAGE<br />
scale:<br />
1/4" = 1'-0"<br />
BASEMENT<br />
sheet:<br />
BSMT / CRAWL<br />
FLOOR LEVEL KEY<br />
NTS<br />
S4.0 A1.1
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
4<br />
S4.1<br />
consultants:<br />
HH6 @ HDR TO 6x<br />
Dibble Engineers, Inc.<br />
25 Central Way, Suite 210<br />
Kirkland, WA 98033<br />
Tel. 425 . 883 . 1900<br />
Fax 425 . 417 . 3735<br />
6x6<br />
6x6 HDR<br />
SW1<br />
(2) 2x6 FH<br />
HD1<br />
3 1/8 x 10 1/2 GLB 24F-V4<br />
(2) 2x6 FH<br />
SW1<br />
(2) 2x6 FH<br />
HD1<br />
3 1/8 x 10 1/2 GLB 24F-V4<br />
(2) 2x6 FH<br />
SW1<br />
6x6<br />
(2) 2x4<br />
HUCQ-SDS<br />
6x6 HDR<br />
1 3/4 x 14 LSL<br />
(2) 2x4<br />
1 3/4 x 14 LSL<br />
14" TJI 230 @ 16" o.c.<br />
SW2<br />
SW2<br />
6x6<br />
6x6 HDR<br />
1 3/4 x 14 LSL<br />
P.T. 2x12 DECK JOISTS -<br />
6' CANTILEVER, 12' BACKSPAN<br />
ITT @ JOIST TO LSL, TYP.<br />
HD1<br />
SW1<br />
HD1<br />
3 1/8 x 9 GLB 24F-V4<br />
HD<br />
14" TJI 230 @ 16" o.c.<br />
1<br />
S4.1<br />
HD1<br />
SW1<br />
3 1/8 x 9 GLB 24F-V4<br />
HD1<br />
SW1<br />
4x8 HDR<br />
SW2<br />
SW2<br />
HD3<br />
HD3<br />
23/32" APA RATED STURD-I-FLOOR T&G<br />
SHEATHING FACE GRAIN PERPENDICULAR<br />
TO FLOOR FRAMING. GLUE AND NAIL w/<br />
8d @ 12" o.c. FIELD (UNBLOCKED), TYP.<br />
2<br />
S4.1<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
UPPER / BEDROOM<br />
FLOOR FRAMING<br />
PLAN<br />
1<br />
S5.0<br />
UPPER / BEDROOM FLOOR FRAMING PLAN<br />
Scale: 1/4" = 1'-0"<br />
date:<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
stamp:<br />
7973<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
UPPER / STUDIO<br />
UPPER / BDRM<br />
MAIN<br />
LOWER BDRM<br />
GARAGE<br />
scale:<br />
1/4" = 1'-0"<br />
BASEMENT<br />
BSMT / CRAWL<br />
sheet:<br />
FLOOR LEVEL KEY<br />
NTS<br />
A1.1 S5.0
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
6<br />
S7.1<br />
consultants:<br />
2<br />
S4.2<br />
6<br />
S7.1<br />
TALL WALL (15'-16') TO BE FRAMED<br />
w/ 2x6 #2 @ 12" o.c., MIN.<br />
6x6 DF<br />
5 1/8 x 12 GLB 24F-V4<br />
4x6 BRG<br />
SW1<br />
(2) 2x6 FH<br />
(2) 2x6 FH<br />
4x6<br />
(2) 2x6 FH<br />
4x6<br />
6x6 DF<br />
Dibble Engineers, Inc.<br />
25 Central Way, Suite 210<br />
Kirkland, WA 98033<br />
Tel. 425 . 883 . 1900<br />
Fax 425 . 417 . 3735<br />
1<br />
S4.2<br />
3<br />
S7.1<br />
4<br />
S7.1<br />
6x6 DF<br />
4x6 FH<br />
4x6 DF<br />
SW1<br />
SW1<br />
HD1<br />
HD1<br />
STL. BRACE<br />
STL. BRACE<br />
@ 16" o.c.<br />
P.T. 2x10s<br />
5 1/8 x 18 GLB 24F-V4<br />
2x6 DF CAR DECKING,<br />
TYP.<br />
SW1<br />
5 1/8 x 12 P.T. GLB 24F-V4<br />
5<br />
S4.1<br />
7<br />
S4.1<br />
@ 16" o.c.<br />
4x6 DF<br />
SW2<br />
3 1/8 x 13 1/2 GLB 24F-V4 @ 4'-0" o.c. (+/-), TYP.<br />
4x6 BRG<br />
@ 24" o.c.<br />
2x8s<br />
w/ LUs TO RIM<br />
4x6 DF<br />
(2) 2x6 FH<br />
SW3<br />
4x10<br />
16d @ 6" o.c.<br />
END 2x TO RIM<br />
5 1/4 x 11 7/8 PSL 2.0E<br />
4x6 DF<br />
(2) 2x6 BRG<br />
(2) 2x6 FH<br />
(2) 2x6 BRG<br />
4x6 HDR<br />
(2) 2x6 FH<br />
(2) 2x6 BRG<br />
HD1<br />
4x6<br />
6x10<br />
(2) 2x6 FH<br />
(2) 2x6 BRG<br />
CS16 BEAM TO BLCK'G<br />
SW3<br />
(2) 2x6 FH<br />
@ 4' o.c., +/-<br />
4x6s<br />
SW1<br />
4 x 8, TYP.<br />
SW1<br />
6x10<br />
7<br />
HH TO 6x POST, TYP.<br />
HH6<br />
6x6<br />
6x6<br />
S7.1<br />
10<br />
S7.1<br />
6x10<br />
HH6<br />
6x6<br />
HH6<br />
6x6<br />
(2) 2x6 FH<br />
SW3<br />
(2) 2x6 FH<br />
3 1/8 x 12 GLB 24F-V4 @ 4'-0" o.c. (+/-), TYP.<br />
2x6 DF CAR DECKING,<br />
TYP.<br />
(2) 2x6 FH<br />
6x10 DF 4x6 4x6<br />
(2) 2x6 FH<br />
SW1 SW1 SW1<br />
CS16 @ 4x TO<br />
BLCK'G IN WALL<br />
3 1/2" DIA. PIPE w/ 1/4" WALL THICKNESS, MIN.<br />
USE LCC OR SIM. TO BEAM<br />
NOTES:<br />
6<br />
S7.1<br />
STL. BRACE<br />
1) SEE SHEET S2.0 FOR TYPICAL HEADER FRAMING<br />
U.N.O. ON PLAN.<br />
2) CS16 TOTAL LENGTH = 3 FT.<br />
CENTER @ JOINT AND FILL EVERY HOLE w/ 8d, U.N.O.<br />
(2) 2x6 FH<br />
SW1<br />
4<br />
S7.1<br />
3<br />
S7.1<br />
date:<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
UPPER STUDIO<br />
FLOOR FRAMING,<br />
MAIN ROOF<br />
FRAMING<br />
PLANS<br />
2<br />
S4.1<br />
HD1<br />
6x6<br />
HD1<br />
SW1<br />
4x6 HDR<br />
6<br />
S4.1<br />
11 7/8 TJI 230<br />
6 3/4 x 18 P.T. GLB<br />
11 7/8 TJI 230 @ 16" o.c.<br />
6x6<br />
6x6 BRG<br />
SW1 SW1<br />
HD1<br />
HD1<br />
3<br />
S4.2<br />
1<br />
S6.0<br />
UPPER STUDIO FLOOR FRAMING PLAN / MAIN ROOF FRAMING PLAN<br />
Scale: 1/4" = 1'-0"<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
7973<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
4x6 FH<br />
UPPER / STUDIO<br />
SW1<br />
6x6 BRG<br />
5 1/8 x 19 1/2 GLB 24F-V4<br />
4x6 FH<br />
SW1<br />
HD1<br />
UPPER / BDRM<br />
MAIN<br />
LOWER BDRM<br />
GARAGE<br />
scale:<br />
1/4" = 1'-0"<br />
23/32" APA RATED STURD-I-FLOOR T&G<br />
SHEATHING FACE GRAIN PERPENDICULAR<br />
TO FLOOR FRAMING. GLUE AND NAIL w/<br />
8d @ 12" o.c. FIELD (UNBLOCKED), TYP.<br />
(2) A35 @ FH 4x TO TOP & BOTTOM<br />
PLATE (4 TOTAL @ EACH 4x), TYP.<br />
STITCH GARAGE DOOR FH 4x TO BRG 6x<br />
w/ 3/8" DIA. THROUGH-BOLTS @ 12" o.c.<br />
(STAGGERED), COUNTERSINK @ 6x BRG, TYP.<br />
BASEMENT<br />
BSMT / CRAWL<br />
FLOOR LEVEL KEY<br />
NTS<br />
sheet:<br />
A1.1 S6.0
s i l o<br />
ARCHITECTURE + DESIGN<br />
1807 NW Dock Place<br />
Seattle, Washington 98107, U.S.A.<br />
Tel. 206 . 851 . 0055<br />
gbelau@mindspring.com<br />
consultants:<br />
Dibble Engineers, Inc.<br />
25 Central Way, Suite 210<br />
Kirkland, WA 98033<br />
Tel. 425 . 883 . 1900<br />
Fax 425 . 417 . 3735<br />
OVER-FRAMING<br />
@ ROOF BELOW<br />
6<br />
S7.1<br />
F A L L C I T Y H O U S E<br />
S E 4 8 t h S t r e e t<br />
F a l l C i t y, W a s h i n g t o n<br />
SW2<br />
SW1<br />
(2) 2x6 FH<br />
4x10 HDR<br />
(2) 2x6 FH<br />
SW1<br />
4x6 HDR<br />
SW1<br />
UPPER STUDIO<br />
ROOF FRAMING<br />
PLANS<br />
4<br />
S7.1<br />
3<br />
S7.1<br />
PROVIDE SLIP CONNECTION @<br />
BEAM TO WALL CONDITIONS<br />
PER ARCH., TYP.<br />
(2) 2x6 FH<br />
(2) 2x6 FH<br />
SW2<br />
(2) 2x6 FH<br />
2x6 DF CAR DECKING,<br />
TYP.<br />
5 1/8 x 16 1/2 GLB 24F-V4 @ 4'-0" o.c. (+/-), TYP.<br />
SW1 SW1<br />
(2) 2x6 FH<br />
(2) 2x6 FH<br />
PROVIDE 3/8" SLIP GAP BETWEEN<br />
CEILING & WALL (AFTER ROOF<br />
INSTALLATION) PER ARCH., TYP.<br />
3<br />
S7.1<br />
4<br />
S7.1<br />
1<br />
S7.0<br />
UPPER STUDIO ROOF FRAMING PLAN<br />
Scale: 1/4" = 1'-0"<br />
date:<br />
09.24.07 CONST. PROGRESS PRINTING<br />
O3.20.07<br />
O2.15.07<br />
stamp:<br />
7973<br />
STRUCTURAL SUBMITTAL<br />
K.C. PERMIT SUBMITTAL<br />
REGISTERED<br />
ARCHITECT<br />
GEOFF BELAU<br />
STATE OF WASHINGTON<br />
UPPER / STUDIO<br />
6x6 DF<br />
5 1/8 x 10 1/2 GLB 24F-V4<br />
6x6 DF BRG<br />
(2) 2x6 FH<br />
SW1<br />
UPPER / BDRM<br />
MAIN<br />
LOWER BDRM<br />
GARAGE<br />
scale:<br />
1/4" = 1'-0"<br />
5<br />
S7.1<br />
BASEMENT<br />
BSMT / CRAWL<br />
FLOOR LEVEL KEY<br />
NTS<br />
sheet:<br />
S7.0