GRUNDFOS<br />

PRODUCT GUIDE<br />

HS<br />

<strong>Horizontal</strong> <strong>single</strong>-<strong>stage</strong> <strong>end</strong>-<strong>suction</strong> <strong>pumps</strong><br />

<strong>60</strong> <strong>Hz</strong>


Contents<br />

General data<br />

Applications page 4<br />

Type key page 4<br />

Performance range, HS page 4<br />

<strong>Pump</strong>ed liquids page 5<br />

Operating conditions page 5<br />

Motor page 5<br />

<strong>Pump</strong> page 5<br />

Materials page 5<br />

Technical data<br />

Dimensions page 6<br />

Dimensional sketch, HS 1/2 - 3 hp page 6<br />

Dimensional sketch, HS 5 - 7 1/2 hp page 6<br />

Performance curves/electrical data, HS 100 page 7<br />

Performance curves/electrical data, HS 125 page 8<br />

Performance curves/electrical data, HS 150 page 9<br />

2


Mission<br />

- to successfully develop, produce, and sell high quality<br />

<strong>pumps</strong> and pumping systems worldwide, contributing to a<br />

better quality of life and healthier environment<br />

GBJ - Bjerringbro, Denmark<br />

GMU - Fresno, California<br />

GPU - Olathe, Kansas<br />

GMX - Monterrey, Mexico GPA - Allentown, Pennsylvania GCA - Oakville, Ontario, Canada<br />

• One of the 3 largest pump companies in the world<br />

• World headquarters in Denmark<br />

• North American headquarters in Kansas City - Manufacturing in Fresno, California<br />

• <strong>60</strong> companies in 40 countries<br />

• More than 10 million <strong>pumps</strong> produced annually worldwide<br />

• North American companies operating in USA, Canada and Mexico<br />

• Continuous reinvestment in growth and development enables the company to<br />

BE responsible, THINK ahead, and INNOVATE<br />

3


General data<br />

HS<br />

Applications<br />

The HS range of compact, horizontal, centrifugal <strong>pumps</strong><br />

is designed for small domestic and industrial water<br />

supply systems.<br />

Applications include:<br />

• Liquid transfer:<br />

Transfer and circulation of liquids within light industry<br />

and farming.<br />

• Pressure boosting<br />

• Air conditioning<br />

• Domestic water supply<br />

• Water fountains<br />

• Cooling systems<br />

• Air-conditioning systems<br />

• Light irrigation<br />

In addition to this, the HS range is suitable for incorporation<br />

in specialized OEM equipment.<br />

(OEM = Original Equipment Manufacturer)<br />

Type key<br />

HS<br />

Example HS 125 1515<br />

<strong>Pump</strong> type<br />

Discharge size (/100)<br />

Nominal HP for ODP motor (/10)<br />

Nominal HP for TEFC motor (/10)<br />

Performance range, HS<br />

H [m]<br />

50<br />

40<br />

H [ft]<br />

1<strong>60</strong><br />

140<br />

120<br />

HS<br />

<strong>60</strong> <strong>Hz</strong><br />

3450 RPM<br />

30<br />

100<br />

80<br />

20<br />

<strong>60</strong><br />

HS 150<br />

10<br />

40<br />

HS 100<br />

HS 125<br />

20<br />

0<br />

0<br />

0 20 40 <strong>60</strong> 80 100 120 140 Q [US GPM]<br />

0 5 10 15 20 25 30 35 Q [m³/h]<br />

TK02 0150 3303<br />

4


General data<br />

HS<br />

<strong>Pump</strong>ed liquids<br />

Thin, clean, non-aggressive and non-explosive liquids<br />

without solid particles or fibers.<br />

Operating conditions<br />

Liquid temp.:<br />

-5°F to +180°F (-20°C to +82°C)<br />

continuous<br />

-5°F to +211°F (-20°C to +99°C)<br />

intermittent<br />

Max. ambient temp.: +104°F (+40°C)<br />

Max. operating press.: 125 psi (8.6 bar)<br />

Minimum inlet press.: According to the NPSHR curve<br />

plus a safety margin of 3 ft.<br />

Maximum inlet press.: Limited by maximum operating<br />

pressure.<br />

<strong>Pump</strong><br />

The HS <strong>pumps</strong> are non-self-priming, <strong>single</strong>-<strong>stage</strong>, horizontal<br />

centrifugal <strong>pumps</strong> with mechanical shaft seal<br />

and close coupled pump/motor shaft. The <strong>pumps</strong> have<br />

an axial <strong>suction</strong> port and radial discharge port and are<br />

mounted on a base plate.<br />

Buna-N O-rings are standard.<br />

For pipe connections see table below.<br />

Connections HS 100 HS 125 HS 150<br />

Axial <strong>suction</strong> port 1 1/4” NPT 1 1/2” NPT 2” NPT<br />

Radial discharge port 1” NPT 1 1/4” NPT 1 1/2” NPT<br />

Motor<br />

The pump is fitted with a heavy-duty, Grundfos-specified<br />

motor.<br />

Electrical data<br />

Mounting designation NEMA<br />

Insulation class<br />

F<br />

Efficiency class<br />

Standard Efficiency<br />

EPAct - on request<br />

High Efficiency - on request<br />

Enclosure class<br />

ODP - Open Drip Proof<br />

TEFC - Totally Enclosed Fan Cooled<br />

<strong>60</strong> <strong>Hz</strong> Standard voltages 1 x 115/208-230V<br />

3 x 208-230/4<strong>60</strong>V<br />

Approvals Motors are<br />

®<br />

rated.<br />

Single-phase motors have built-in thermal overload<br />

protection. Three-phase motors must be connected to a<br />

motor starter according to local regulations.<br />

Direction of rotation: Clockwise from motor <strong>end</strong>.<br />

Materials, HS<br />

Description<br />

<strong>Pump</strong> housing, motor stool,<br />

base plate<br />

Impeller<br />

HS 100, HS 125<br />

<strong>Pump</strong> shaft<br />

HS 150<br />

Shaft seal<br />

Material<br />

Cast iron<br />

Brass<br />

Brass<br />

AISI 416 SS<br />

Carbon/ceramic with Buna-N<br />

elastomer and stainless steel parts<br />

(FKM elastomers optional)<br />

5


Performance curves<br />

HS 100<br />

H [m]<br />

20<br />

18<br />

16<br />

H [ft]<br />

65<br />

<strong>60</strong><br />

55<br />

0707<br />

0505<br />

35%<br />

40%<br />

HS 100<br />

<strong>60</strong> <strong>Hz</strong><br />

3450 RPM<br />

14<br />

50<br />

45<br />

40%<br />

45%<br />

45%<br />

46%<br />

12<br />

10<br />

40<br />

35<br />

30<br />

47%<br />

45%<br />

45%<br />

40%<br />

8<br />

25<br />

40%<br />

35%<br />

6<br />

20<br />

35%<br />

4<br />

2<br />

15<br />

10<br />

5<br />

0<br />

0<br />

0 5 10 15 20 25 30 35 40 45 Q [US GPM]<br />

P2<br />

[kW]<br />

0.4<br />

0.2<br />

0.0<br />

P2<br />

[hp]<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0.0<br />

0 2 4 6 8 10 Q [m³/h]<br />

0 5 10 15 20 25 30 35 40 45 Q [US GPM]<br />

NPSH<br />

H [m] [ft]<br />

0707<br />

40<br />

0505<br />

10<br />

30<br />

5<br />

0<br />

20<br />

10<br />

0<br />

NPSHR<br />

0 5 10 15 20 25 30 35 40 45 Q [US GPM]<br />

0505<br />

0707<br />

TK01 0100 2903<br />

6


Technical data<br />

HS 100<br />

Dimensional sketch, HS 100<br />

B 5 7/8<br />

2 1/4<br />

DISCHARGE<br />

SUCTION<br />

C<br />

4 1/2<br />

3 3/8<br />

A<br />

83/4<br />

4 3/4<br />

3 7/8<br />

57/8 45/8 4 7/8<br />

Dimensions, HS 100<br />

<strong>Pump</strong> type HP PH<br />

NEMA<br />

Frame<br />

Size<br />

Suc.<br />

Size<br />

[in]<br />

Dis.<br />

Size<br />

[in]<br />

Open drip proof (ODP) motor<br />

A [in] B [in] C [in]<br />

Ship<br />

wt.<br />

[lbs]<br />

Totally enclosed fan cooled (TEFC) motor<br />

A [in] B [in] C [in]<br />

HS 100 0505 1/2 1 56C 1 1/4 1 4 3/8 9 3/8 4 3/4 47 5 9 3/8 5 53 1.7<br />

3 - 9 1/4 4 3/8 50 - 9 3/8 5 47 1.7<br />

HS 100 0707 3/4 1 56C 1 1/4 1 5 11 4 7/8 50 5 1/8 10 5 57 1.7<br />

3 - 9 1/2 4 3/8 51 - 9 3/8 5 50 1.7<br />

Ship<br />

wt.<br />

[lbs]<br />

Ship<br />

vol.<br />

[ft 3 ]<br />

Electrical data, HS 100<br />

<strong>Pump</strong> type HP PH Voltage<br />

TEFC voltage is: *115/230<br />

S.F.<br />

Open drip proof (ODP) motor<br />

Full load<br />

current [A]<br />

S.F. current<br />

[A]<br />

Start current<br />

[A]<br />

S.F.<br />

Totally enclosed fan cooled (TEFC) motor<br />

Full load<br />

current<br />

[A]<br />

S.F. current<br />

[A]<br />

Start current<br />

[A]<br />

HS 100 0505 1/2 1 115/208-230* 1.25 7.2/4.0-3.6 8.0/4.4-4.0 30/16.6-15 1.6 7.4/4.1-3.7 9.8/5.2-4.9 39/21.6-19.5<br />

3 208-230/4<strong>60</strong> 1.25 2.1-2.0/1.0 2.6-2.4/1.2 13.3-12/6.0 1.25 2.1-2.0/1.0 2.6-2.4/1.2 13.3-12/6.0<br />

HS 100 0707 3/4 1 115/208-230* 1.25 9.6/5.3-4.8 11.4/6.3-5.7 56/31-28 1.25 9.6/4.8 11.4/5.7 56/28<br />

3 208-230/4<strong>60</strong> 1.25 2.7-2.6/1.3 3.1-3.0/1.5 16.8-15.2/7.6 1.25 2.7-2.6/1.3 3.1-3.0/1.5 16.8-15.2/7.6<br />

7


Performance curves<br />

HS 125<br />

H [m]<br />

25<br />

H [ft]<br />

90<br />

80<br />

2020<br />

1515<br />

40%<br />

45%<br />

50%<br />

55%<br />

HS 125<br />

<strong>60</strong> <strong>Hz</strong><br />

3450 RPM<br />

20<br />

70<br />

1010<br />

40%<br />

45%<br />

50%<br />

55%<br />

<strong>60</strong>%<br />

61%<br />

15<br />

<strong>60</strong><br />

50<br />

45%<br />

50%<br />

55%<br />

<strong>60</strong>%<br />

65%<br />

66%<br />

<strong>60</strong>%<br />

<strong>60</strong>%<br />

55%<br />

40<br />

65%<br />

55%<br />

50%<br />

10<br />

30<br />

<strong>60</strong>%<br />

55%<br />

20<br />

5<br />

10<br />

0<br />

0<br />

0 10 20 30 40 50 <strong>60</strong> 70 Q [US GPM]<br />

P2<br />

[kW]<br />

1.0<br />

0.5<br />

P2<br />

[hp]<br />

1.5<br />

1.0<br />

0.5<br />

0 5 10 15 Q [m³/h]<br />

2020<br />

1515<br />

1010<br />

0.0 0.0<br />

0 10 20 30 40 50 <strong>60</strong> 70 Q [US GPM]<br />

NPSH<br />

H [m] [ft]<br />

2020<br />

1515<br />

5<br />

20<br />

NPSHR<br />

1010<br />

10<br />

0<br />

0<br />

0 10 20 30 40 50 <strong>60</strong> 70 Q [US GPM]<br />

TK01 0125 2903<br />

8


Technical data<br />

HS 125<br />

Dimensional sketch, HS 125<br />

B 5 7/8<br />

2 1/4<br />

DISCHARGE<br />

SUCTION<br />

C<br />

4 1/2<br />

3 3/8<br />

A<br />

83/4<br />

4 3/4<br />

3 7/8<br />

57/8 45/8 4 7/8<br />

Dimensions, HS 125<br />

<strong>Pump</strong> type HP PH<br />

NEMA<br />

Frame<br />

Size<br />

Suc.<br />

Size<br />

[in]<br />

Dis.<br />

Size<br />

[in]<br />

Open drip proof (ODP) motor<br />

A [in] B [in] C [in]<br />

Ship<br />

wt.<br />

[lbs]<br />

Totally enclosed fan cooled (TEFC)<br />

motor<br />

A [in] B [in] C [in]<br />

HS 125 1010 1 1 56C 1 1/2 1 1/4 5 5/8 11 1/4 5 5/8 52 5 5/8 11 1/4 5 3/4 68 1.7<br />

3 - 9 1/2 5 5/8 51 - 10 1/4 5 3/4 50 1.7<br />

HS 125 1515 1 1/2 1 56C 1 1/2 1 1/4 5 1/2 11 3/4 5 5/8 54 5 5/8 11 3/4 5 3/4 70 1.7<br />

3 - 10 3/4 5 5/8 55 - 10 3/4 5 3/4 57 1.7<br />

HS 125 2020 2 1 56C 1 1/2 1 1/4 5 1/2 11 3/4 5 5/8 37 5 5/8 12 5/8 5 3/4 77 1.7<br />

3 - 10 3/4 5 5/8 66 - 11 3/4 5 3/4 66 1.7<br />

Ship<br />

wt.<br />

[lbs]<br />

Ship<br />

vol.<br />

[ft 3 ]<br />

Electrical data, HS 125<br />

<strong>Pump</strong> type HP PH Voltage<br />

TEFC voltage is: *115/230<br />

S.F.<br />

Open drip proof (ODP) motor<br />

Full load<br />

current [A]<br />

S.F. current<br />

[A]<br />

Start current<br />

[A]<br />

S.F.<br />

Totally enclosed fan cooled (TEFC) motor<br />

Full load<br />

current<br />

[A]<br />

S.F. current<br />

[A]<br />

Start<br />

current [A]<br />

HS 125 1010 1 1 115/208-230 1.4 10/5.5-5.0 15/8.0-7.5 85/47-42.5 1.25 12/6.0 14.4/7.2 77/38.5<br />

3 208-230/4<strong>60</strong> 1.25 3.4-3.2/1.6 3.8-3.6/1.8 19.5-17.6/8.9 1.25 3.4-3.2/1.6 3.8-3.6/1.8 19.7-17.8/8.9<br />

HS 125 1515 1 1/2 1 115/208-230* 1.15 18/10-9 19.7/10.7-9.7 121/66.8-<strong>60</strong>.4 1.3 17/9.5-8.6 20.4/11.3-10.2 106/58.6-53<br />

3 208-230/4<strong>60</strong> 1.15 5.0-4.6/2.3 5.4-5.0/2.5 35.4-32/16 1.15 5.0-4.6/2.3 5.4-5.2/2.6 35.4-32/16<br />

HS 125 2020 2 1 115/208-230* 1.15 24/13.3-12 27.6/15.3-13.8 1<strong>60</strong>/88.5-80 1.15 23/11.5 25.4/12.7 156/78<br />

3 208-230/4<strong>60</strong> 1.15 5.9-5.6/2.8 6.7-6.4/3.2 40.9-37/18.5 1.15 5.7-5.4/2.7 6.5-6.2/3.1 38.7-35/17.5<br />

9


Performance curves<br />

HS 150<br />

H [m]<br />

50<br />

H [ft]<br />

1<strong>60</strong><br />

7575<br />

40% 45%<br />

50%<br />

55%<br />

HS 150<br />

<strong>60</strong> <strong>Hz</strong><br />

3450 RPM<br />

140<br />

<strong>60</strong>%<br />

40<br />

120<br />

5050<br />

40%<br />

65%<br />

30<br />

20<br />

100<br />

80<br />

<strong>60</strong><br />

3030<br />

2020<br />

45%<br />

40% 45%<br />

50%<br />

55%<br />

<strong>60</strong>%<br />

45%<br />

50%<br />

55%<br />

<strong>60</strong>%<br />

50%<br />

65%<br />

66%<br />

65%<br />

62%<br />

<strong>60</strong>%<br />

55%<br />

55%<br />

<strong>60</strong>%<br />

55%<br />

50%<br />

<strong>60</strong>%<br />

55%<br />

50%<br />

45%<br />

50%<br />

45%<br />

10<br />

40<br />

50%<br />

45%<br />

20<br />

0<br />

0<br />

0 20 40 <strong>60</strong> 80 100 120 140 1<strong>60</strong> Q [US GPM]<br />

P2<br />

[kW]<br />

4<br />

2<br />

P2<br />

[hp]<br />

6<br />

4<br />

2<br />

0 5 10 15 20 25 30 35 40 Q [m³/h]<br />

7575<br />

5050<br />

3030<br />

2020<br />

0<br />

H [m]<br />

5<br />

0<br />

NPSH<br />

[ft]<br />

20<br />

10<br />

0 20 40 <strong>60</strong> 80 100 120 140 1<strong>60</strong> Q [US GPM]<br />

NPSHR<br />

2020<br />

3030<br />

5050<br />

7575<br />

0<br />

0<br />

0 20 40 <strong>60</strong> 80 100 120 140 1<strong>60</strong> Q [US GPM]<br />

TK01 0150 2903<br />

10


Technical data<br />

HS 150<br />

Dimensional sketch, HS 150 Large<br />

Dimensional sketch, HS 150 Small<br />

B<br />

81/2<br />

2 1/4<br />

DISCHARGE<br />

SUCTION<br />

C 5 1/8<br />

3 7/8<br />

B 6 1/8<br />

DISCHARGE<br />

SUCTION<br />

C<br />

2 1/4<br />

5 1/8<br />

33/8<br />

A<br />

9 1/4<br />

A<br />

9<br />

5<br />

4 3/4<br />

61/2<br />

12<br />

7 1/2<br />

8 5/8<br />

3 7/8<br />

5 7/8 4 7/8 4 7/8<br />

Dimensions, HS 150<br />

<strong>Pump</strong> type HP PH<br />

NEMA<br />

Frame<br />

Size<br />

Suc.<br />

Size<br />

[in]<br />

Dis.<br />

Size<br />

[in]<br />

Open drip proof (ODP) motor<br />

A [in] B [in] C [in]<br />

Ship<br />

wt.<br />

[lbs]<br />

Totally enclosed fan cooled (TEFC)<br />

motor<br />

A [in] B [in] C [in]<br />

HS 150 2020 2 1 56C 2 1 1/2 5 1/2 11 3/4 5 5/8 37 5 5/8 12 5/8 5 3/4 83 1.7<br />

3 - 10 3/4 5 5/8 66 - 11 3/4 5 3/4 72 1.7<br />

HS 150 3030 3 1 56C 2 1 1/2 5 1/2 12 1/8 5 1/4 85 6 1/4 13 6 103 1.7<br />

3 - 11 1/4 5 1/8 78 - 12 1/8 5 3/4 81 1.7<br />

HS 150 5050 5 1 184TC 2 1 1/2 6 5/8 12 1/4 6 3/4 116 6 5/8 15 1/4 6 130 1.7<br />

3 182TC - 12 1/4 6 3/4 113 - 13 3/4 6 7/8 115 1.7<br />

HS 150 7575 7 1/2 3 184TC 2 1 1/2 - 12 1/4 6 3/4 118 - 15 1/4 6 7/8 129 1.7<br />

Ship<br />

wt.<br />

[lbs]<br />

Ship<br />

vol.<br />

[ft 3 ]<br />

Electrical data, HS 150<br />

<strong>Pump</strong> type HP PH Voltage<br />

TEFC voltage is: *115/230, **115/208-230, ***230<br />

S.F.<br />

Open drip proof (ODP) motor<br />

Full load<br />

current [A]<br />

S.F. current<br />

[A]<br />

Start current<br />

[A]<br />

S.F.<br />

Totally enclosed fan cooled (TEFC) motor<br />

Full load<br />

current<br />

[A]<br />

S.F. current<br />

[A]<br />

Start<br />

current [A]<br />

HS 150 2020 2 1 115/208-230* 1.15 24/13.3-12 27.6/15.3-13.8 1<strong>60</strong>/88.5-80 1.15 23/11.5 25.4/12.7 156/78<br />

3 208-230/4<strong>60</strong> 1.15 5.9-5.6/2.8 6.7-6.4/3.2 40.9-37/18.5 1.15 5.7-5.4/2.7 6.5-6.2/3.1 38.7-35/17.5<br />

HS 150 3030 3 1 230** 1.15 13 14.8 108 1.15 30/16.5-15 32.2/17.8-16.1 172/95.1-86<br />

3 208-230/4<strong>60</strong> 1.15 8.4-8.0/4.0 9.2-8.7/4.4 66.3-<strong>60</strong>/30 1.15 7.8-7.4/3.7 9.5-8.6/4.3 59.7-54/27<br />

HS 150 5050 5 1 208-230*** 1.15 24-23 30.1-27.2 138-125 1.15 21 24.2 124<br />

HS 150 7575<br />

3 208-230/430 1.15 13.1-11.5/5.7 15.3-13.8/6.9 106-96/48 1.15 13-12/6.0 14.8-13.4/6.7 123.8-112/56<br />

7 1/2 3 208-230/4<strong>60</strong> 1.15 19-18/9.0<br />

22.3-20.2/<br />

10.1<br />

168-152/76 1.15 18.5-17.4/8.7 21.7-19.6/9.8<br />

207.9-188/<br />

94<br />

11


12<br />

This page intentionally left blank.


Submittal Data Sheet<br />

Company name:<br />

Prepared by:<br />

HS<br />

Phone number: ( ) -<br />

Fax number: ( ) -<br />

<strong>Horizontal</strong> Single-<strong>stage</strong> Centrifugal <strong>Pump</strong>s Date: Page 1 of:<br />

Quote number:<br />

Client Information<br />

Project title:<br />

Client name:<br />

Reference number:<br />

Client number:<br />

Client contact: Client phone no: ( ) -<br />

Location Information<br />

For:<br />

Unit:<br />

Site:<br />

Service:<br />

Address: City: State: Zip Code:<br />

Application Information<br />

Operating Conditions<br />

<strong>Pump</strong>ed Fluid<br />

max. norm. min. Fluid type:<br />

Capacity (gpm) rated max. norm.<br />

Suction Pressure (psig)<br />

Fluid Temperature (°F)<br />

Discharge Pressure (psig)<br />

at designated temperature<br />

Differential Head (ft)<br />

Specific Gravity<br />

Hydraulic Power (hp)<br />

Vapor Pressure (psia)<br />

at designated capacity<br />

Viscosity (cp)<br />

NPSH Available (ft) Fluid ph: Chlorides (ppm):<br />

Hazardous:<br />

Flammable:<br />

Service<br />

Other:<br />

Continuous: Intermittent (starts/day): Corrosion/Errosion caused by:<br />

% Solids: Max. particle size (in):<br />

<strong>Pump</strong> Information<br />

Model Information from Type Key and Codes:<br />

Quantity Required:<br />

Example: HS 125 1015<br />

Minimum required flow:<br />

NPSH required at duty point:<br />

Product Guide additional information pages<br />

Materials page number:<br />

Performance curve page number:<br />

Technical data page number:<br />

Motor data page number:<br />

Motor Information<br />

HP: Phase: Voltage: Enclosure:<br />

Additional Information<br />

13


14<br />

This page intentionally left blank.


Quotation Text<br />

HS<br />

<strong>Horizontal</strong>, <strong>single</strong>-<strong>stage</strong>, non-self-priming, centrifugal pump with axial <strong>suction</strong> port and radial discharge port.<br />

The compact unit has maintenance-free mechanical shaft seal and a close-coupled motor/pump shaft.<br />

<strong>Pump</strong> and motor are mounted on a common baseplate and the tangentia discharge can be rotated to any of four positions.<br />

The motor is a ______-phase motor.<br />

Technical:<br />

Rated flow:<br />

_______________ GPM<br />

Rated head:<br />

_______________ Feet<br />

Minimum liquid temperature: _______________ °F<br />

Maximum liquid temperature: _______________ °F<br />

Type of shaft seal:<br />

_______________<br />

Materials:<br />

Material, pump housing:<br />

Cast iron<br />

Material, impeller:<br />

Bronze<br />

Material, shaft:<br />

_______________<br />

Material, seal metal: Stainless Steel<br />

- seal face: Carbon<br />

- seal face Ceramic<br />

- seal elastomer: _______________<br />

Installation:<br />

Minimum ambient temperature: _______________ °F<br />

Maximum ambient temperature: _______________ °F<br />

Maximum operating pressure:<br />

_______________ PSI<br />

Max. pressure at stated temp.:<br />

_______________ PSI/°F<br />

Size, pipe connection:<br />

_______________ Suction/Discharge ” NPT<br />

/<br />

Electrical data:<br />

Rated power (P2):<br />

Frequency:<br />

Rated voltage:<br />

Rated current:<br />

Service factor:<br />

Rated speed:<br />

Enclosure class:<br />

Insulation class:<br />

_______________ HP<br />

_______________ <strong>Hz</strong><br />

_______________ V<br />

_______________ A<br />

_______________<br />

_______________ RPM<br />

_______________<br />

F<br />

Additional:<br />

Gross weight:<br />

_______________ Lbs.<br />

Shipping volume: _______________ ft 3<br />

155


Being responsible is our foundation<br />

Thinking ahead makes it possible<br />

Innovation is the essence<br />

L-HS-PG-001 11/03<br />

PRINTEDINUSA<br />

Subject to alterations.<br />

GRUNDFOS <strong>Pump</strong>s Corporation<br />

17100 West 118th Terrace<br />

Olathe, Kansas 6<strong>60</strong>61<br />

Phone: 913 227 3400<br />

Fax: 913 227 3500<br />

www.grundfos.com<br />

GRUNDFOS Canada Inc.<br />

2941 Brighton Road<br />

Oakville, Ontario Canada L6H 6C9<br />

Phone: 905 829 9533<br />

Fax: 905 829 9512<br />

Bombas GRUNDFOS de Mexico S.A. de C.V.<br />

Boulevard TLC No. 15<br />

Parque Industrial Stiva Aeropuerto<br />

Apodaca, N.L. Mexico 66<strong>60</strong>0<br />

Phone: 52 81 8144 4000<br />

Fax: 52 81 8144 4010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!