<strong>AMVM96</strong> / <strong>ACVM96</strong><br />
Heating Input: 60,000–115,000 BTU/h<br />
* Complete warranty details available from your local dealer or at<br />
www.amana-hac.com. To receive the Lifetime Unit Replacement<br />
Limited Warranty (good for as long as you own your home) and<br />
the 10-Year Parts Limited Warranty, online registration must be<br />
completed within 60 days of installation. Online registration is not<br />
required in California or Québec.<br />
Modulating<br />
Variable Speed Gas Furnace<br />
Up to 96% AFUE<br />
Standard Features<br />
• ComfortNet Communicating Systems compatible<br />
• Heavy-duty Million-Air® stainless-steel<br />
dual-diameter, tubular heat exchanger<br />
• Stainless-steel secondary heat exchanger<br />
• Self-calibrating modulating gas valve auto-confiures<br />
for each installation<br />
• Durable SureStart Silicon Nitride igniter<br />
• Quiet variable-speed induced draft blower<br />
• Utilizes ComfortNet communicating, two-stage or<br />
single-stage thermostats<br />
• Self-diagnostic control board with constant memory<br />
fault code history output to a dual 7-segment display<br />
• Color-coded low-voltage terminals with provisions for<br />
electronic air cleaner and humidifier<br />
• Efficient and quiet variable-speed airflow system gently<br />
ramps up or down according to heating or cooling demand<br />
• Multiple continuous fan speed options offer<br />
quiet air circulation<br />
• Auto-Comfort and enhanced dehumidification<br />
modes available<br />
• All models comply with California Low NOx<br />
emissions standards<br />
Cabinet Features<br />
• Multi-position installation: upflow, horizontal left or right<br />
• Certified for direct vent (2-pipe) or non-direct vent (1-pipe)<br />
• Easy-to-install top venting with optional side venting<br />
• Designed for multi-position installation —<br />
<strong>AMVM96</strong>: upflow, horizontal left or right<br />
<strong>ACVM96</strong>: downflow, horizontal left or right<br />
• Convenient left or right connection<br />
for gas and electrical service<br />
• Cabinet air leakage (Q Leak ) ≤ 2%<br />
• Heavy-gauge steel cabinet with durable<br />
baked-enamel finish<br />
• Fully insulated heat exchanger and blower section<br />
• Airtight solid bottom or side return with easy-cut tabs<br />
for effortless removal in bottom air-inlet applications<br />
Contents<br />
Nomenclature........................................ 2<br />
Product Specifications........................... 3<br />
Dimensions............................................ 4<br />
Airflow Specifications............................. 6<br />
Wiring Diagram.....................................11<br />
Accessories........................................... 12<br />
Thermostats......................................... 12<br />
SS-<strong>AMVM96</strong> www.amana-hac.com 9/13<br />
<strong>Amana</strong>® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.
Product Specifications<br />
Nomenclature<br />
A<br />
1<br />
M<br />
2<br />
V M 96 060 4 C X A A<br />
3 4 5,6 7,8,9 10 11 12 13 14<br />
Brand<br />
Revisions<br />
A <strong>Amana</strong> ® Brand A Ini,al Releases (Major & Minor)<br />
B 1st Revisions (Major & Minor)<br />
C 2nd Revisions<br />
Airflow Direc6on<br />
C Downflow/Horizontal NOx<br />
D Dedicated Downflow N Natural Gas<br />
H High Airflow X Low NOx<br />
K Dedicated Upflow<br />
M Upflow/Horizontal Cabinet Width<br />
A 14”<br />
Descrip6on/Motor B 17½”<br />
V Two-‐Stage/Variable-‐speed C 21”<br />
H Two-‐Stage/Mul,-‐speed D 24½”<br />
S Single-‐Stage/Mul,-‐speed<br />
E Two-‐Stage/High-‐Efficiency Maximum CFM @ 0.5” ESP<br />
3 1200<br />
SystemType 4 1600<br />
C ComfortNet Communica,ng System 5 2000<br />
M Modula,ng Furnace MBTU/h<br />
045: 45,000<br />
AFUE 060: 60,000<br />
96 96% 9 90%+ 080: 80,000<br />
95 95% 8 80% 100: 100,000<br />
115: 115,000<br />
2 www.amana-hac.com SS-<strong>AMVM96</strong>
Product Specifications<br />
Specifications<br />
Heating Capacity<br />
<strong>AMVM96</strong><br />
0603BXB*<br />
<strong>AMVM96</strong><br />
0805CXB*<br />
<strong>AMVM96</strong><br />
1005DXB*<br />
<strong>AMVM96</strong><br />
1155DXB*<br />
<strong>ACVM96</strong><br />
0604CXB*<br />
<strong>ACVM96</strong><br />
0805DXB*<br />
<strong>ACVM96</strong><br />
1005DX<br />
High Fire Input (BTU/h)¹ 60,000 80,000 100,000 115,000 60,000 80,000 100,000<br />
High Fire Output (BTU/h)¹ 57,600 76,800 96,000 109,250 57,600 76,800 95,000<br />
Low-Fire Steady-State Input¹ 30,000 40,000 50,000 57,500 30,000 40,000 50,000<br />
Low-Fire Steady-State Output¹ 28,800 38,400 48,000 54,625 28,800 38,400 47,500<br />
AFUE² 96 96 96 95 96 96 95<br />
Available AC @ 0.5” ESP 1.5-3.0 2.0-5.0 2.0-5.0 2.0-5.0 1.5-4.0 2.0-5.0 2.0-5.0<br />
Temperature Rise Range (° F) 20-50 35-65 35-65 35-65 20-50 20-50 25-55<br />
Circulator Blower<br />
Size (D x W) 10" X 8" 11" X 10" 11" X 10" 11" X 10" 10"X 10" 11" X 10" 11" X 10"<br />
Horsepower @ 1050 RPM 3/4 1 1 1 3/4 1 1<br />
Speed Variable Variable Variable Variable Variable Variable Variable<br />
Vent Diameter³ 2" 3" 3" 3" 2" 2" 2"<br />
No. of Burners 3 4 5 5 3 4 4<br />
Disposable Filter (in 2 ) 576 960 960 972 641 854 1,056<br />
Electrical Data<br />
Min. Circuit Ampacity⁴ 10.6 14.2 14.2 14.2 6.0 14.2 14.2<br />
Max. Overcurrent Device (amps)⁵ 15.0 15.0 15.0 15.0 15.0 15.0 15.0<br />
Ship Weight (lbs) 132 150 165 165 139 160 165<br />
¹ Natural Gas BTU/h<br />
² DOE AFUE based upon Isolated Combustion System (ICS)<br />
³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in<br />
diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent<br />
on installation/code requirements and must be 2” or 3” diameter PVC.<br />
⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with<br />
National Electrical Codes. Extensive wire runs will require larger wire sizes.<br />
⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type<br />
circuit breakers of the same size as noted.<br />
Notes<br />
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.<br />
• Gas Service Connection ½” FPT<br />
• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.<br />
SS-<strong>AMVM96</strong> www.amana-hac.com 3
Product Specifications<br />
<strong>AMVM96</strong> Dimensions<br />
¾<br />
19⅞<br />
28¾<br />
2½<br />
¾<br />
¾<br />
2¹/₁₆<br />
7⅜<br />
2¹¹/₁₆<br />
1¾<br />
4⅛<br />
30¼<br />
24⁹/₁₆<br />
6⅛<br />
1½<br />
2⅝<br />
21¼<br />
27⅛ 2⅝<br />
30¼ 19³/₁₆<br />
1¾<br />
11¾<br />
19³/₁₆<br />
16⅝<br />
32¹³/₁₆<br />
11¾<br />
1¾<br />
1⅝<br />
22 ¹/₁₆<br />
FOLDED FLANGES<br />
23 ⁹/₁₆<br />
UNFOLDED FLANGES<br />
LEFT SIDE VIEW<br />
FOLDED FLANGES<br />
D<br />
UNFOLDED FLANGES<br />
E<br />
FRONT VIEW<br />
RIGHT SIDE VIEW<br />
Model W D H A B C D E<br />
<strong>AMVM96</strong>0603BXB* 17½” 28¾" 40¾" 17½” 16" 13⅛" 12⅛" 13⅝"<br />
<strong>AMVM96</strong>0805CXB* 21" 28¾" 40¾" 21" 19½” 16⅛" 16" 17½”<br />
<strong>AMVM96</strong>1005DXB* 24½” 28¾" 40¾" 24½” 23" 20⅝" 19⅜" 20⅞"<br />
<strong>AMVM96</strong>1155DXB* 24½” 28¾" 40¾" 24½” 23" 20⅝" 19⅜" 20⅞"<br />
Notes:<br />
• Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2”<br />
or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air<br />
Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.<br />
• Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace.<br />
• Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.<br />
• Installer must supply following gas line fittings, according to which entrance is used:<br />
Left—Two 90º elbows, one close nipple, straight pipe<br />
Right—Straight pipe to reach gas valve<br />
• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.<br />
Minimum Clearances to Combustible Materials<br />
Position Sides Rear Front Bottom Flue Top<br />
Upflow 0” 0” 3” C 0” 1”<br />
Horizontal 6” 0” 3” C 0” 6”<br />
C = If placed on combustible floor, the floor MUST be wood ONLY.<br />
Notes:<br />
• For servicing or cleaning, a 24” front clearance is required.<br />
• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.<br />
• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.<br />
4 www.amana-hac.com SS-<strong>AMVM96</strong>
Product Specifications<br />
<strong>ACVM96</strong> Dimensions<br />
LEFT SIDE<br />
VIEW<br />
FRONTVIEW<br />
RIGHT SIDE<br />
VIEW<br />
28 3/4<br />
3/4 20 1/4 2 1/2<br />
AIR INTAKE PIPE<br />
2" PVC<br />
3/4<br />
A<br />
B<br />
(RETURN)<br />
C<br />
3/4<br />
2 1/16<br />
VENT/FLUE PIPE<br />
2" PVC<br />
LOW VOLTAGE<br />
ELECTRICAL HOLE<br />
1 3/4<br />
40<br />
CONDENSATE<br />
DRAIN TRAP<br />
w/ 3/4" PVC<br />
DISCHARGE<br />
(RIGHT OR<br />
LEFT SIDE)<br />
1 3/4<br />
LOW VOLTAGE<br />
ELECTRICAL HOLE<br />
HIGH VOLTAGE<br />
ELECTRICAL HOLE<br />
HIGH VOLTAGE<br />
ELECTRICAL HOLE<br />
LEFT SIDE<br />
DRAIN LINE<br />
HOLES<br />
STANDARD GAS<br />
SUPPLY HOLE<br />
DRAIN<br />
TRAP<br />
CL<br />
2 5/8<br />
4 1/8<br />
11 1/2<br />
9 13/16<br />
15 1/2<br />
28 5/16<br />
2<br />
8 1/4<br />
28 5/16<br />
19 7/8<br />
18 13/16<br />
14<br />
6 1/8<br />
2 11/16<br />
11 5/8<br />
9 3/4<br />
7 3/8<br />
ALTERNATE<br />
VENT/FLUE<br />
LOCATION<br />
ALTERNATE<br />
AIR INTAKE LOCATION<br />
DRAIN<br />
2 5/8<br />
TRAP CL<br />
RIGHT SIDE<br />
DRAIN LINE<br />
HOLES<br />
ALTERNATE GAS<br />
SUPPLY HOLE<br />
18 5/8<br />
UNFOLDED FLANGES<br />
20 5/32<br />
UNFOLDED FLANGES<br />
AIR<br />
DISCHARGE<br />
D<br />
UNFOLDED FLANGES<br />
E<br />
UNFOLDED<br />
FOLDED FLANGES<br />
FLANGES<br />
DISCHARGE<br />
AIR<br />
DISCHARGE<br />
Model W D H A B C D E<br />
ACMV960604CXB* 21" 28¾" 40¾" 21" 19½” 16⅛" 18" 19½”<br />
<strong>ACVM96</strong>0805DXB* 24½" 28¾" 40¾" 24½” 23" 20⅝" 21½" 23"<br />
<strong>ACVM96</strong>1005DX 24½" 28¾" 40¾" 24½” 23" 20⅝" 21½" 23"<br />
Notes:<br />
• Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2”<br />
or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air<br />
Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.<br />
• Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace.<br />
• Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.<br />
• Installer must supply following gas line fittings, according to which entrance is used:<br />
Left—Two 90º elbows, one close nipple, straight pipe<br />
Right—Straight pipe to reach gas valve<br />
• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.<br />
Minimum Clearances to Combustible Materials<br />
Position Sides Rear Front Bottom Flue Top<br />
Downflow 0” 0” 3” NC 0” 1”<br />
Horizontal 6” 0” 3” C 0” 6”<br />
C = If placed on combustible floor, the floor MUST be wood ONLY.<br />
NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.<br />
Notes<br />
• For servicing or cleaning, a 24” front clearance is required.<br />
• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.<br />
• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.<br />
SS-<strong>AMVM96</strong> www.amana-hac.com 5
Product Specifications<br />
<strong>AMVM96</strong> Airflow Data<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
<strong>AMVM96</strong>0603BX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
<strong>AMVM96</strong>0603BX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 20 - 50°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 567 351<br />
Minus 10% 855 62<br />
A<br />
Normal 630 390 Normal 950 56<br />
Plus 10% 693 429 Plus 10% 1,045 51<br />
Minus 10% 720 495<br />
Normal 800 550 C Normal 1,050 51<br />
Rise<br />
(°F)<br />
Minus 10% 945 56<br />
Plus 10% 880 605 Plus 10% 1,155 46<br />
Minus 10% 900 612<br />
Minus 10% 1,053 50<br />
Normal 1000 680 D Normal 1,170 45<br />
Plus 10% 1100 748 Plus 10% 1,287 41<br />
Minus 10% 1089 720<br />
Minus 10% 1,143 46<br />
Normal 1210 800 D Normal 1,270 42<br />
Plus 10% 1331 880 Plus 10% 1,397 38<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
AVMV960805CX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
AVMV960805CX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 35 - 65°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 747 486<br />
Minus 10% 1,440 49<br />
A<br />
Normal 830 540 Normal 1,600 44<br />
Plus 10% 913 594 Plus 10% 1,760 40<br />
Minus 10% 981 675<br />
Normal 1090 750 B Normal 1,690 42<br />
Rise<br />
(°F)<br />
Minus 10% 1,521 47<br />
Plus 10% 1199 825 Plus 10% 1,859 38<br />
Minus 10% 1314 882<br />
Minus 10% 1,620 44<br />
Normal 1460 980 C Normal 1,800 39<br />
Plus 10% 1606 1078 Plus 10% 1,980 36<br />
Minus 10% 1620 1089<br />
Minus 10% 1,701 42<br />
Normal 1800 1210 D Normal 1,890 37<br />
Plus 10% 1980 1331 Plus 10% 2,079 34<br />
Notes:<br />
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.<br />
• For most jobs, about 400 CFM per ton when cooling is desirable.<br />
• Do not operate above .5” w.c. ESP in heating mode.<br />
Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.<br />
6 www.amana-hac.com SS-<strong>AMVM96</strong>
Product Specifications<br />
<strong>AMVM96</strong> Airflow Data (cont.)<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
<strong>AMVM96</strong>1005DX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
<strong>AMVM96</strong>1005DX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 25 - 65°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 711 459<br />
Minus 10% 1,629 54<br />
A<br />
Normal 790 510 Normal 1,810 49<br />
Plus 10% 869 561 Plus 10% 1,991 44<br />
Minus 10% 990 639<br />
Minus 10% 1,665 53<br />
Normal 1100 710 C Normal 1,850 48<br />
Plus 10% 1210 781 Plus 10% 2,035 43<br />
Minus 10% 1269 819<br />
Minus 10% 1,701 52<br />
Normal 1410 910 D Normal 1,890 47<br />
Plus 10% 1551 1001 Plus 10% 2,079 43<br />
Minus 10% 1647 1044<br />
Normal 1830 1160 D Normal 1,940 46<br />
Rise<br />
(°F)<br />
Minus 10% 1,746 51<br />
Plus 10% 2013 1276 Plus 10% 2,134 41<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
<strong>AMVM96</strong>1155DX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
<strong>AMVM96</strong>1155DX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 35 - 65°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 711 459<br />
Minus 10% 1,629 62<br />
A<br />
Normal 790 510 Normal 1,810 56<br />
Plus 10% 869 561 Plus 10% 1,991 51<br />
Minus 10% 990 639<br />
Minus 10% 1,665 60<br />
Normal 1100 710 B Normal 1,850 54<br />
Plus 10% 1210 781 Plus 10% 2,035 49<br />
Minus 10% 1269 819<br />
Minus 10% 1,701 59<br />
Normal 1410 910 C Normal 1,890 53<br />
Plus 10% 1551 1001 Plus 10% 2,079 48<br />
Minus 10% 1647 1044<br />
Normal 1830 1160 D Normal 1,940 52<br />
Rise<br />
(°F)<br />
Minus 10% 1,746 58<br />
Plus 10% 2013 1276 Plus 10% 2,134 47<br />
Notes<br />
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.<br />
• For most jobs, about 400 CFM per ton when cooling is desirable.<br />
• Operation is recommended below .5˝ w.c. ESP in heating mode. Operating CFM between .5˝ and .8˝ w.c.<br />
is tabulated for cooling purposes only.<br />
• 100% CFM shown. CFM will vary proportionally with the gas valve BTU/H input.<br />
SS-<strong>AMVM96</strong> www.amana-hac.com 7
Product Specifications<br />
<strong>ACVM96</strong> Airflow Data<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
<strong>ACVM96</strong>0604CX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
<strong>ACVM96</strong>0604CX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 20 - 50°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 594 333<br />
Minus 10% 1,098 48<br />
A<br />
Normal 660 370 Normal 1,220 44<br />
Plus 10% 726 407 Plus 10% 1,342 40<br />
Minus 10% 774 486<br />
Normal 860 540 C Normal 1,340 40<br />
Rise<br />
(°F)<br />
Minus 10% 1,206 44<br />
Plus 10% 946 594 Plus 10% 1,474 36<br />
Minus 10% 1035 711<br />
Minus 10% 1,314 40<br />
Normal 1150 790 D Normal 1,460 36<br />
Plus 10% 1265 869 Plus 10% 1,606 33<br />
Minus 10% 1323 882<br />
Minus 10% 1,431 37<br />
Normal 1470 980 D Normal 1,590 33<br />
Plus 10% 1617 1078 Plus 10% 1,749 30<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
<strong>ACVM96</strong>0805DX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
DC96MC0805DX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 20 - 50°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 810 477<br />
Minus 10% 1,440 49<br />
A<br />
Normal 900 530 Normal 1,600 44<br />
Plus 10% 990 583 Plus 10% 1,760 40<br />
Minus 10% 990 657<br />
Normal 1100 730 B Normal 1,710 41<br />
Rise<br />
(°F)<br />
Minus 10% 1,539 46<br />
Plus 10% 1210 803 Plus 10% 1,881 38<br />
Minus 10% 1287 837<br />
Minus 10% 1,620 44<br />
Normal 1430 930 C Normal 1,800 39<br />
Plus 10% 1573 1023 Plus 10% 1,980 36<br />
Minus 10% 1692 1098<br />
Minus 10% 1,719 41<br />
Normal 1880 1220 D Normal 1,910 37<br />
Plus 10% 2068 1342 Plus 10% 2,101 34<br />
Notes:<br />
• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.<br />
• For most jobs, about 400 CFM per ton when cooling is desirable.<br />
• Operation is recommended below .5” w.c. ESP in heating mode.<br />
Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.<br />
8 www.amana-hac.com SS-<strong>AMVM96</strong>
Product Specifications<br />
<strong>ACVM96</strong> Airflow Data (cont.)<br />
Tap<br />
A<br />
B<br />
C<br />
D<br />
Adjust<br />
<strong>ACVM96</strong>1005DX<br />
Cooling Speed<br />
(@ .1˝ - .8˝ w.c. ESP)<br />
High-Stage<br />
CFM<br />
Low-Stage<br />
CFM<br />
Tap<br />
<strong>ACVM96</strong>1005DX<br />
Heating Speed<br />
(@ .1˝ - .5˝ w.c. ESP; Rise Range: 25 - 55°F)<br />
Adjust<br />
High-Stage<br />
CFM<br />
Minus 10% 702 450<br />
Minus 10% 1,557 56<br />
A<br />
Normal 780 500 Normal 1,730 51<br />
Plus 10% 858 550 Plus 10% 1,903 46<br />
Minus 10% 963 666<br />
Minus 10% 1,593 55<br />
Normal 1070 740 B Normal 1,770 49<br />
Plus 10% 1177 814 Plus 10% 1,947 45<br />
Minus 10% 1242 828<br />
Minus 10% 1,656 53<br />
Normal 1380 920 C Normal 1,840 48<br />
Plus 10% 1518 1012 Plus 10% 2,024 43<br />
Minus 10% 1602 1044<br />
Minus 10% 1,683 52<br />
Normal 1780 1160 D Normal 1,870 47<br />
Plus 10% 1958 1276 Plus 10% 2,057 43<br />
Rise<br />
(°F)<br />
Notes<br />
• All furnaces ship as high speed for cooling. Installer must adjust blower<br />
speed as needed.<br />
• For most jobs, about 400 CFM per ton when cooling is desirable.<br />
• Operation is recommended below .5” w.c. ESP in heating mode. Operating<br />
CFM between .5” and .8” w.c. is tabulated for cooling purposes only.<br />
• 100% CFM shown. CFM will vary proportionally with the gas valve BTU/H input.<br />
SS-<strong>AMVM96</strong> www.amana-hac.com 9
Product Specifications<br />
Temperature Rise Range Chart<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
BTU BTU/h OUTPUT Output vs TEMPERATURE Vs. Temperature RISE Rise Chart CHART<br />
600 CFM<br />
700<br />
800<br />
900<br />
1000<br />
1100<br />
1200<br />
1400<br />
1600<br />
1800<br />
2000<br />
2200<br />
2400 CFM<br />
FORMULAS<br />
BTU BTU/h OUTPUT Output = = CFM x 1.08 x x Rise RISE<br />
RISE<br />
Rise<br />
=<br />
=<br />
Formulas<br />
BTU OUTPUT<br />
BTU/H Output<br />
1.08<br />
CFM x 1.08<br />
÷ CFM<br />
30 40 50 60 70 80 90 100 110 120 130 140 150<br />
OUTPUT Output BTU/h BTU/HR x 1,000 x 1000<br />
TEMPERATURE Temperature Rise RISE<br />
10 www.amana-hac.com SS-<strong>AMVM96</strong>
4<br />
3<br />
2<br />
1<br />
7<br />
4<br />
1<br />
8<br />
5<br />
2<br />
9<br />
6<br />
3<br />
2<br />
1<br />
Product Specifications<br />
Wiring Diagram<br />
WH<br />
WH<br />
HOT<br />
SURFACE<br />
IGNITER<br />
2<br />
WH<br />
1<br />
RD<br />
WH<br />
2 CIRCUIT<br />
CONNECTOR<br />
MODULATING<br />
GAS VALVE<br />
(HONEY WELL)<br />
PU<br />
WH<br />
RD<br />
BLOWER COMPARTMENT<br />
AUTO RESET<br />
AUXILIARY<br />
LIMIT CONTROL<br />
BK<br />
PU<br />
FLAME<br />
SENSOR<br />
COOL TAPS<br />
1<br />
RAMPING<br />
1<br />
2<br />
3<br />
COOL SETUP<br />
HEAT SETUP<br />
2<br />
DEHUM<br />
ECM MTR<br />
HARNESS BK BL<br />
RD GY<br />
3<br />
3<br />
2<br />
1<br />
HEAT TAPS<br />
ID BLOWER<br />
CONNECTOR<br />
ADJUST<br />
FUSE<br />
LOW FIRE<br />
PRESSURE<br />
SWITCH<br />
BL<br />
DIAGNOSTIC<br />
LED'S<br />
DELAY<br />
PULL DOWN<br />
PULL UP<br />
BIAS<br />
24 V 3A<br />
4<br />
FAN TAPS<br />
OR<br />
WH<br />
2<br />
5<br />
4<br />
3<br />
2<br />
1<br />
R<br />
BR<br />
GY<br />
C<br />
C<br />
PK<br />
G<br />
GY<br />
W1<br />
BK<br />
WH<br />
GR<br />
NOTES:<br />
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.<br />
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE<br />
USED WHEN SERVICING.<br />
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE<br />
FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH<br />
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT<br />
LEAST 105°C. USE COPPER CONDUCTORS ONLY.<br />
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO<br />
N.E.C. AND LOCAL CODES.<br />
5. TO RECALL THE LAST 10 FAULTS, MOST RECENT TO LEAST<br />
RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS<br />
WHILE IN STANDBY (NO THERMOSTAT INPUTS)<br />
C<br />
PM<br />
HEAT OFF<br />
RD<br />
BK<br />
24V HUM.<br />
1<br />
DIP SWITCHES<br />
BR<br />
AUTO RESET PRIMARY<br />
LIMIT CONTROL<br />
BURNER COMPARTMENT<br />
CIRCULATOR BLOWER<br />
MODULATING INTERGRATED<br />
FURNACE CONTROL MODULE<br />
OR<br />
PK<br />
ID BLOWER TWO-STAGE PRESSURE<br />
SWITCH ASSEMBLY<br />
NO<br />
NO<br />
W2<br />
OR<br />
Y1<br />
WH<br />
Y2<br />
OR<br />
PU<br />
O<br />
LINE<br />
HSI<br />
EAC<br />
HUM<br />
DEHUM<br />
BR<br />
10<br />
11<br />
12<br />
AUX<br />
NEUTRAL<br />
OR<br />
OR<br />
NO<br />
GY<br />
FRONT COVER<br />
PRESSURE SWITCH<br />
GND<br />
OR<br />
YL<br />
MANUAL RESET ROLLOUT LIMIT CONTROLS<br />
(SINGLE CONTROL ON 45 kBTU)<br />
24 V THERMOSTAT CONNECTIONS<br />
C<br />
GND<br />
YL<br />
C<br />
INDUCED<br />
DRAFT<br />
BLOWER<br />
RD<br />
RD<br />
OR<br />
OR<br />
BK GY<br />
BK<br />
BL<br />
INDUCTOR COIL<br />
70kBTU,90kBTU,<br />
115kBTU MODELS<br />
ONLY<br />
0140F01166-A<br />
BK<br />
HIGH FIRE<br />
PRESSURE<br />
SWITCH<br />
PU<br />
BR<br />
BR<br />
YL<br />
COLOR CODES:<br />
PK PINK<br />
BR BROWN<br />
WH WHITE<br />
BL BLUE<br />
GY GRAY<br />
RD RED<br />
YL YELLOW<br />
OR ORANGE<br />
PU PURPLE<br />
GR GREEN<br />
BK BLACK<br />
FLAME<br />
SENSOR<br />
BK<br />
WH<br />
BL<br />
40 VA<br />
TRANSFORMER<br />
GR<br />
24<br />
VAC<br />
115<br />
VAC<br />
WH<br />
CHASSIS<br />
GROUND<br />
JUNCTION BOX<br />
GY<br />
BK<br />
BK<br />
BLOWER<br />
COMPARTMENT<br />
DOOR SWITCH<br />
(OPEN WHEN<br />
DOOR OPEN)<br />
JUNCTION<br />
TERMINAL<br />
WH<br />
WARNING:<br />
DISCONNECT POWER<br />
BEFORE SERVICING<br />
WIRING TO UNIT<br />
MUST BE PROPERLY<br />
POLARIZED AND<br />
GROUNDED.<br />
INTEGRATED CONTROL MODULE 24V THERMOSTAT CONNECTIONS<br />
24V HUM.<br />
R<br />
Y1<br />
W1<br />
W2<br />
Y2<br />
G<br />
O<br />
DEHUM<br />
C<br />
TO<br />
R<br />
DISCONNECT<br />
DOOR<br />
SWITCH<br />
INDUCTOR COIL<br />
70kBTU,90kBTU,<br />
115kBTU MODELS<br />
ONLY<br />
LINE<br />
TO<br />
MICRO<br />
LINE<br />
EAC<br />
HUM<br />
IGN<br />
FS<br />
3<br />
2<br />
1<br />
(2)<br />
(7)<br />
(10)<br />
FLAME<br />
SENSOR<br />
INTEGRATED CONTROL<br />
MODULE<br />
HUMIDIFIER<br />
OPTIONAL<br />
L<br />
WARNING:DISCONNECT<br />
POWER BEFORE SERVICING<br />
N WIRING. TO UNIT MUST BE<br />
PROPERLY POLARIZED<br />
AND GROUNDED.<br />
INDOOR<br />
AIR<br />
CIRCULATOR<br />
BLWR<br />
115<br />
VAC<br />
GND<br />
NO<br />
FIELD GND<br />
GND<br />
NEUTRAL<br />
40 VA<br />
FUSE 3A TR (5)<br />
TRANSFORMER<br />
24 VAC AUTO RESET PRIMARY<br />
AUTO RESET AUXILIARY LIMIT LIMIT CONTROL<br />
TO+VDC CONTROLS<br />
(3)<br />
TO<br />
MICRO<br />
LOW VOLTAGE FIELD<br />
LOW VOLTAGE (24V)<br />
HI VOLTAGE (115V)<br />
HI VOLTAGE FIELD<br />
INTERNAL TO<br />
INTEGRATED CONTROL<br />
PLUG CONNECTION<br />
(6)<br />
(12)<br />
(11)<br />
(8)<br />
GND (4)<br />
TR (9)<br />
ELECTRONIC<br />
AIR CLEANER<br />
OPTIONAL<br />
NO<br />
JUNCTION BOX<br />
3Ø ID<br />
BLWR<br />
HUMIDIFIER<br />
OPTIONAL<br />
HIGH FIRE<br />
PRESS. SWITCH<br />
GND (4)<br />
+ VDC (1)<br />
RX (2)<br />
TX (3)<br />
TO<br />
GND 115 VAC/1 Ø /60 HZ<br />
POWER SUPPLY WITH<br />
OVERCURRENT<br />
PROTECTION<br />
L DEVICE<br />
TO 115VAC/1 Ø /60 HZ POWER SUPPLY WITH<br />
OVERCURRENT PROTECTION DEVICE<br />
HOT SURFACE<br />
IGNITER<br />
C<br />
GND<br />
NO<br />
IGNITER<br />
C<br />
N<br />
INDOOR<br />
AIR<br />
CIRCULATOR<br />
BLWR<br />
EQUIPMENT GND<br />
FIELD SPLICE<br />
SWITCH (TEMP)<br />
OVERCURRENT<br />
PROT. DEVICE<br />
TO UNIT MUST BE<br />
DISCONNECT<br />
NEUTRAL<br />
NEUTRAL<br />
NEUTRAL<br />
NEUTRAL<br />
SWITCH PRESSURE<br />
LOW FIRE<br />
PRESS.<br />
SWITCH<br />
C<br />
MANUAL RESET ROLLOUT<br />
LIMIT CONTROLS<br />
FRONT COVER<br />
PRESS.<br />
SWITCH<br />
PM<br />
C<br />
GAS<br />
VALVE<br />
INTEGRATED CONTROL MODULE<br />
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power<br />
sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡<br />
Wiring is subject to change. Always<br />
refer to the wiring diagram or the ⚠ Warning<br />
unit for the most up-to-date wiring.<br />
SS-<strong>AMVM96</strong> www.amana-hac.com 11
Product Specifications<br />
Thermostats<br />
CTK03 ComfortNet-compatible Control<br />
(See ComfortNet website (www.comfortnet1.com) for details.)<br />
CTK02 ComfortNet-compatible Control<br />
(See ComfortNet website (www.comfortnet1.com) for details.)<br />
CTK01 ComfortNet-compatible Control<br />
(See ComfortNet website (www.comfortnet1.com) for details.)<br />
Accessories<br />
Model<br />
LPKM0D060UF<br />
Description<br />
<strong>AMVM96</strong><br />
0603BX<br />
<strong>AMVM96</strong><br />
0805CX<br />
<strong>AMVM96</strong><br />
1005DX<br />
<strong>AMVM96</strong><br />
1155DX<br />
<strong>ACVM96</strong><br />
0604CX<br />
LPKM0D100UF --- --- √ --- --- ---<br />
LP Conversion Kits<br />
LPKM0D115UF --- --- --- √ --- ---<br />
<strong>ACVM96</strong><br />
0805DX<br />
√ --- --- --- --- ---<br />
LPKM0D080UF --- √ --- --- --- ---<br />
LPKM0D060CF --- --- --- --- √ ---<br />
LPKM0D080CF --- --- --- --- --- √<br />
EFR01 External Filter Rack √ √ √ √ √ √<br />
DCVK-20 Horizontal/Vertical Concentric Vent Kit (2”) √ √ √ --- √ ---<br />
DCVK-30 Horizontal/Vertical Concentric Vent Kit (3”) √ √ √ √ √ √<br />
CFB21 Downflow Floor Base --- --- --- --- √ ---<br />
CFB24 Downflow Floor Base --- --- --- --- --- √<br />
0170K00000S Flush-mount vent kit √ √ √ √ √ √<br />
Notes<br />
√ Indicates available for this model<br />
• For installation in Canada, gas furnaces are certified only to 4,500’.<br />