<strong>AMVM96</strong> / <strong>ACVM96</strong><br />

Heating Input: 60,000–115,000 BTU/h<br />

* Complete warranty details available from your local dealer or at<br />

www.amana-hac.com. To receive the Lifetime Unit Replacement<br />

Limited Warranty (good for as long as you own your home) and<br />

the 10-Year Parts Limited Warranty, online registration must be<br />

completed within 60 days of installation. Online registration is not<br />

required in California or Québec.<br />

Modulating<br />

Variable Speed Gas Furnace<br />

Up to 96% AFUE<br />

Standard Features<br />

• ComfortNet Communicating Systems compatible<br />

• Heavy-duty Million-Air® stainless-steel<br />

dual-diameter, tubular heat exchanger<br />

• Stainless-steel secondary heat exchanger<br />

• Self-calibrating modulating gas valve auto-confiures<br />

for each installation<br />

• Durable SureStart Silicon Nitride igniter<br />

• Quiet variable-speed induced draft blower<br />

• Utilizes ComfortNet communicating, two-stage or<br />

single-stage thermostats<br />

• Self-diagnostic control board with constant memory<br />

fault code history output to a dual 7-segment display<br />

• Color-coded low-voltage terminals with provisions for<br />

electronic air cleaner and humidifier<br />

• Efficient and quiet variable-speed airflow system gently<br />

ramps up or down according to heating or cooling demand<br />

• Multiple continuous fan speed options offer<br />

quiet air circulation<br />

• Auto-Comfort and enhanced dehumidification<br />

modes available<br />

• All models comply with California Low NOx<br />

emissions standards<br />

Cabinet Features<br />

• Multi-position installation: upflow, horizontal left or right<br />

• Certified for direct vent (2-pipe) or non-direct vent (1-pipe)<br />

• Easy-to-install top venting with optional side venting<br />

• Designed for multi-position installation —<br />

<strong>AMVM96</strong>: upflow, horizontal left or right<br />

<strong>ACVM96</strong>: downflow, horizontal left or right<br />

• Convenient left or right connection<br />

for gas and electrical service<br />

• Cabinet air leakage (Q Leak ) ≤ 2%<br />

• Heavy-gauge steel cabinet with durable<br />

baked-enamel finish<br />

• Fully insulated heat exchanger and blower section<br />

• Airtight solid bottom or side return with easy-cut tabs<br />

for effortless removal in bottom air-inlet applications<br />

Contents<br />

Nomenclature........................................ 2<br />

Product Specifications........................... 3<br />

Dimensions............................................ 4<br />

Airflow Specifications............................. 6<br />

Wiring Diagram.....................................11<br />

Accessories........................................... 12<br />

Thermostats......................................... 12<br />

SS-<strong>AMVM96</strong> www.amana-hac.com 9/13<br />

<strong>Amana</strong>® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.


Product Specifications<br />

Nomenclature<br />

A<br />

1<br />

M<br />

2<br />

V M 96 060 4 C X A A<br />

3 4 5,6 7,8,9 10 11 12 13 14<br />

Brand<br />

Revisions<br />

A <strong>Amana</strong> ® Brand A Ini,al Releases (Major & Minor)<br />

B 1st Revisions (Major & Minor)<br />

C 2nd Revisions<br />

Airflow Direc6on<br />

C Downflow/Horizontal NOx<br />

D Dedicated Downflow N Natural Gas<br />

H High Airflow X Low NOx<br />

K Dedicated Upflow<br />

M Upflow/Horizontal Cabinet Width<br />

A 14”<br />

Descrip6on/Motor B 17½”<br />

V Two-­‐Stage/Variable-­‐speed C 21”<br />

H Two-­‐Stage/Mul,-­‐speed D 24½”<br />

S Single-­‐Stage/Mul,-­‐speed<br />

E Two-­‐Stage/High-­‐Efficiency Maximum CFM @ 0.5” ESP<br />

3 1200<br />

SystemType 4 1600<br />

C ComfortNet Communica,ng System 5 2000<br />

M Modula,ng Furnace MBTU/h<br />

045: 45,000<br />

AFUE 060: 60,000<br />

96 96% 9 90%+ 080: 80,000<br />

95 95% 8 80% 100: 100,000<br />

115: 115,000<br />

2 www.amana-hac.com SS-<strong>AMVM96</strong>


Product Specifications<br />

Specifications<br />

Heating Capacity<br />

<strong>AMVM96</strong><br />

0603BXB*<br />

<strong>AMVM96</strong><br />

0805CXB*<br />

<strong>AMVM96</strong><br />

1005DXB*<br />

<strong>AMVM96</strong><br />

1155DXB*<br />

<strong>ACVM96</strong><br />

0604CXB*<br />

<strong>ACVM96</strong><br />

0805DXB*<br />

<strong>ACVM96</strong><br />

1005DX<br />

High Fire Input (BTU/h)¹ 60,000 80,000 100,000 115,000 60,000 80,000 100,000<br />

High Fire Output (BTU/h)¹ 57,600 76,800 96,000 109,250 57,600 76,800 95,000<br />

Low-Fire Steady-State Input¹ 30,000 40,000 50,000 57,500 30,000 40,000 50,000<br />

Low-Fire Steady-State Output¹ 28,800 38,400 48,000 54,625 28,800 38,400 47,500<br />

AFUE² 96 96 96 95 96 96 95<br />

Available AC @ 0.5” ESP 1.5-3.0 2.0-5.0 2.0-5.0 2.0-5.0 1.5-4.0 2.0-5.0 2.0-5.0<br />

Temperature Rise Range (° F) 20-50 35-65 35-65 35-65 20-50 20-50 25-55<br />

Circulator Blower<br />

Size (D x W) 10" X 8" 11" X 10" 11" X 10" 11" X 10" 10"X 10" 11" X 10" 11" X 10"<br />

Horsepower @ 1050 RPM 3/4 1 1 1 3/4 1 1<br />

Speed Variable Variable Variable Variable Variable Variable Variable<br />

Vent Diameter³ 2" 3" 3" 3" 2" 2" 2"<br />

No. of Burners 3 4 5 5 3 4 4<br />

Disposable Filter (in 2 ) 576 960 960 972 641 854 1,056<br />

Electrical Data<br />

Min. Circuit Ampacity⁴ 10.6 14.2 14.2 14.2 6.0 14.2 14.2<br />

Max. Overcurrent Device (amps)⁵ 15.0 15.0 15.0 15.0 15.0 15.0 15.0<br />

Ship Weight (lbs) 132 150 165 165 139 160 165<br />

¹ Natural Gas BTU/h<br />

² DOE AFUE based upon Isolated Combustion System (ICS)<br />

³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2” or 3” in<br />

diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent<br />

on installation/code requirements and must be 2” or 3” diameter PVC.<br />

⁴ Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with<br />

National Electrical Codes. Extensive wire runs will require larger wire sizes.<br />

⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type<br />

circuit breakers of the same size as noted.<br />

Notes<br />

• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.<br />

• Gas Service Connection ½” FPT<br />

• Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.<br />

SS-<strong>AMVM96</strong> www.amana-hac.com 3


Product Specifications<br />

<strong>AMVM96</strong> Dimensions<br />

¾<br />

19⅞<br />

28¾<br />

2½<br />

¾<br />

¾<br />

2¹/₁₆<br />

7⅜<br />

2¹¹/₁₆<br />

1¾<br />

4⅛<br />

30¼<br />

24⁹/₁₆<br />

6⅛<br />

1½<br />

2⅝<br />

21¼<br />

27⅛ 2⅝<br />

30¼ 19³/₁₆<br />

1¾<br />

11¾<br />

19³/₁₆<br />

16⅝<br />

32¹³/₁₆<br />

11¾<br />

1¾<br />

1⅝<br />

22 ¹/₁₆<br />

FOLDED FLANGES<br />

23 ⁹/₁₆<br />

UNFOLDED FLANGES<br />

LEFT SIDE VIEW<br />

FOLDED FLANGES<br />

D<br />

UNFOLDED FLANGES<br />

E<br />

FRONT VIEW<br />

RIGHT SIDE VIEW<br />

Model W D H A B C D E<br />

<strong>AMVM96</strong>0603BXB* 17½” 28¾" 40¾" 17½” 16" 13⅛" 12⅛" 13⅝"<br />

<strong>AMVM96</strong>0805CXB* 21" 28¾" 40¾" 21" 19½” 16⅛" 16" 17½”<br />

<strong>AMVM96</strong>1005DXB* 24½” 28¾" 40¾" 24½” 23" 20⅝" 19⅜" 20⅞"<br />

<strong>AMVM96</strong>1155DXB* 24½” 28¾" 40¾" 24½” 23" 20⅝" 19⅜" 20⅞"<br />

Notes:<br />

• Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2”<br />

or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air<br />

Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.<br />

• Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace.<br />

• Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.<br />

• Installer must supply following gas line fittings, according to which entrance is used:<br />

Left—Two 90º elbows, one close nipple, straight pipe<br />

Right—Straight pipe to reach gas valve<br />

• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.<br />

Minimum Clearances to Combustible Materials<br />

Position Sides Rear Front Bottom Flue Top<br />

Upflow 0” 0” 3” C 0” 1”<br />

Horizontal 6” 0” 3” C 0” 6”<br />

C = If placed on combustible floor, the floor MUST be wood ONLY.<br />

Notes:<br />

• For servicing or cleaning, a 24” front clearance is required.<br />

• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.<br />

• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.<br />

4 www.amana-hac.com SS-<strong>AMVM96</strong>


Product Specifications<br />

<strong>ACVM96</strong> Dimensions<br />

LEFT SIDE<br />

VIEW<br />

FRONTVIEW<br />

RIGHT SIDE<br />

VIEW<br />

28 3/4<br />

3/4 20 1/4 2 1/2<br />

AIR INTAKE PIPE<br />

2" PVC<br />

3/4<br />

A<br />

B<br />

(RETURN)<br />

C<br />

3/4<br />

2 1/16<br />

VENT/FLUE PIPE<br />

2" PVC<br />

LOW VOLTAGE<br />

ELECTRICAL HOLE<br />

1 3/4<br />

40<br />

CONDENSATE<br />

DRAIN TRAP<br />

w/ 3/4" PVC<br />

DISCHARGE<br />

(RIGHT OR<br />

LEFT SIDE)<br />

1 3/4<br />

LOW VOLTAGE<br />

ELECTRICAL HOLE<br />

HIGH VOLTAGE<br />

ELECTRICAL HOLE<br />

HIGH VOLTAGE<br />

ELECTRICAL HOLE<br />

LEFT SIDE<br />

DRAIN LINE<br />

HOLES<br />

STANDARD GAS<br />

SUPPLY HOLE<br />

DRAIN<br />

TRAP<br />

CL<br />

2 5/8<br />

4 1/8<br />

11 1/2<br />

9 13/16<br />

15 1/2<br />

28 5/16<br />

2<br />

8 1/4<br />

28 5/16<br />

19 7/8<br />

18 13/16<br />

14<br />

6 1/8<br />

2 11/16<br />

11 5/8<br />

9 3/4<br />

7 3/8<br />

ALTERNATE<br />

VENT/FLUE<br />

LOCATION<br />

ALTERNATE<br />

AIR INTAKE LOCATION<br />

DRAIN<br />

2 5/8<br />

TRAP CL<br />

RIGHT SIDE<br />

DRAIN LINE<br />

HOLES<br />

ALTERNATE GAS<br />

SUPPLY HOLE<br />

18 5/8<br />

UNFOLDED FLANGES<br />

20 5/32<br />

UNFOLDED FLANGES<br />

AIR<br />

DISCHARGE<br />

D<br />

UNFOLDED FLANGES<br />

E<br />

UNFOLDED<br />

FOLDED FLANGES<br />

FLANGES<br />

DISCHARGE<br />

AIR<br />

DISCHARGE<br />

Model W D H A B C D E<br />

ACMV960604CXB* 21" 28¾" 40¾" 21" 19½” 16⅛" 18" 19½”<br />

<strong>ACVM96</strong>0805DXB* 24½" 28¾" 40¾" 24½” 23" 20⅝" 21½" 23"<br />

<strong>ACVM96</strong>1005DX 24½" 28¾" 40¾" 24½” 23" 20⅝" 21½" 23"<br />

Notes:<br />

• Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2”<br />

or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air<br />

Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.<br />

• Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of furnace.<br />

• Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.<br />

• Installer must supply following gas line fittings, according to which entrance is used:<br />

Left—Two 90º elbows, one close nipple, straight pipe<br />

Right—Straight pipe to reach gas valve<br />

• For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.<br />

Minimum Clearances to Combustible Materials<br />

Position Sides Rear Front Bottom Flue Top<br />

Downflow 0” 0” 3” NC 0” 1”<br />

Horizontal 6” 0” 3” C 0” 6”<br />

C = If placed on combustible floor, the floor MUST be wood ONLY.<br />

NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.<br />

Notes<br />

• For servicing or cleaning, a 24” front clearance is required.<br />

• Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.<br />

• In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.<br />

SS-<strong>AMVM96</strong> www.amana-hac.com 5


Product Specifications<br />

<strong>AMVM96</strong> Airflow Data<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

<strong>AMVM96</strong>0603BX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

<strong>AMVM96</strong>0603BX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 20 - 50°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 567 351<br />

Minus 10% 855 62<br />

A<br />

Normal 630 390 Normal 950 56<br />

Plus 10% 693 429 Plus 10% 1,045 51<br />

Minus 10% 720 495<br />

Normal 800 550 C Normal 1,050 51<br />

Rise<br />

(°F)<br />

Minus 10% 945 56<br />

Plus 10% 880 605 Plus 10% 1,155 46<br />

Minus 10% 900 612<br />

Minus 10% 1,053 50<br />

Normal 1000 680 D Normal 1,170 45<br />

Plus 10% 1100 748 Plus 10% 1,287 41<br />

Minus 10% 1089 720<br />

Minus 10% 1,143 46<br />

Normal 1210 800 D Normal 1,270 42<br />

Plus 10% 1331 880 Plus 10% 1,397 38<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

AVMV960805CX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

AVMV960805CX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 35 - 65°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 747 486<br />

Minus 10% 1,440 49<br />

A<br />

Normal 830 540 Normal 1,600 44<br />

Plus 10% 913 594 Plus 10% 1,760 40<br />

Minus 10% 981 675<br />

Normal 1090 750 B Normal 1,690 42<br />

Rise<br />

(°F)<br />

Minus 10% 1,521 47<br />

Plus 10% 1199 825 Plus 10% 1,859 38<br />

Minus 10% 1314 882<br />

Minus 10% 1,620 44<br />

Normal 1460 980 C Normal 1,800 39<br />

Plus 10% 1606 1078 Plus 10% 1,980 36<br />

Minus 10% 1620 1089<br />

Minus 10% 1,701 42<br />

Normal 1800 1210 D Normal 1,890 37<br />

Plus 10% 1980 1331 Plus 10% 2,079 34<br />

Notes:<br />

• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.<br />

• For most jobs, about 400 CFM per ton when cooling is desirable.<br />

• Do not operate above .5” w.c. ESP in heating mode.<br />

Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.<br />

6 www.amana-hac.com SS-<strong>AMVM96</strong>


Product Specifications<br />

<strong>AMVM96</strong> Airflow Data (cont.)<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

<strong>AMVM96</strong>1005DX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

<strong>AMVM96</strong>1005DX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 25 - 65°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 711 459<br />

Minus 10% 1,629 54<br />

A<br />

Normal 790 510 Normal 1,810 49<br />

Plus 10% 869 561 Plus 10% 1,991 44<br />

Minus 10% 990 639<br />

Minus 10% 1,665 53<br />

Normal 1100 710 C Normal 1,850 48<br />

Plus 10% 1210 781 Plus 10% 2,035 43<br />

Minus 10% 1269 819<br />

Minus 10% 1,701 52<br />

Normal 1410 910 D Normal 1,890 47<br />

Plus 10% 1551 1001 Plus 10% 2,079 43<br />

Minus 10% 1647 1044<br />

Normal 1830 1160 D Normal 1,940 46<br />

Rise<br />

(°F)<br />

Minus 10% 1,746 51<br />

Plus 10% 2013 1276 Plus 10% 2,134 41<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

<strong>AMVM96</strong>1155DX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

<strong>AMVM96</strong>1155DX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 35 - 65°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 711 459<br />

Minus 10% 1,629 62<br />

A<br />

Normal 790 510 Normal 1,810 56<br />

Plus 10% 869 561 Plus 10% 1,991 51<br />

Minus 10% 990 639<br />

Minus 10% 1,665 60<br />

Normal 1100 710 B Normal 1,850 54<br />

Plus 10% 1210 781 Plus 10% 2,035 49<br />

Minus 10% 1269 819<br />

Minus 10% 1,701 59<br />

Normal 1410 910 C Normal 1,890 53<br />

Plus 10% 1551 1001 Plus 10% 2,079 48<br />

Minus 10% 1647 1044<br />

Normal 1830 1160 D Normal 1,940 52<br />

Rise<br />

(°F)<br />

Minus 10% 1,746 58<br />

Plus 10% 2013 1276 Plus 10% 2,134 47<br />

Notes<br />

• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.<br />

• For most jobs, about 400 CFM per ton when cooling is desirable.<br />

• Operation is recommended below .5˝ w.c. ESP in heating mode. Operating CFM between .5˝ and .8˝ w.c.<br />

is tabulated for cooling purposes only.<br />

• 100% CFM shown. CFM will vary proportionally with the gas valve BTU/H input.<br />

SS-<strong>AMVM96</strong> www.amana-hac.com 7


Product Specifications<br />

<strong>ACVM96</strong> Airflow Data<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

<strong>ACVM96</strong>0604CX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

<strong>ACVM96</strong>0604CX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 20 - 50°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 594 333<br />

Minus 10% 1,098 48<br />

A<br />

Normal 660 370 Normal 1,220 44<br />

Plus 10% 726 407 Plus 10% 1,342 40<br />

Minus 10% 774 486<br />

Normal 860 540 C Normal 1,340 40<br />

Rise<br />

(°F)<br />

Minus 10% 1,206 44<br />

Plus 10% 946 594 Plus 10% 1,474 36<br />

Minus 10% 1035 711<br />

Minus 10% 1,314 40<br />

Normal 1150 790 D Normal 1,460 36<br />

Plus 10% 1265 869 Plus 10% 1,606 33<br />

Minus 10% 1323 882<br />

Minus 10% 1,431 37<br />

Normal 1470 980 D Normal 1,590 33<br />

Plus 10% 1617 1078 Plus 10% 1,749 30<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

<strong>ACVM96</strong>0805DX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

DC96MC0805DX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 20 - 50°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 810 477<br />

Minus 10% 1,440 49<br />

A<br />

Normal 900 530 Normal 1,600 44<br />

Plus 10% 990 583 Plus 10% 1,760 40<br />

Minus 10% 990 657<br />

Normal 1100 730 B Normal 1,710 41<br />

Rise<br />

(°F)<br />

Minus 10% 1,539 46<br />

Plus 10% 1210 803 Plus 10% 1,881 38<br />

Minus 10% 1287 837<br />

Minus 10% 1,620 44<br />

Normal 1430 930 C Normal 1,800 39<br />

Plus 10% 1573 1023 Plus 10% 1,980 36<br />

Minus 10% 1692 1098<br />

Minus 10% 1,719 41<br />

Normal 1880 1220 D Normal 1,910 37<br />

Plus 10% 2068 1342 Plus 10% 2,101 34<br />

Notes:<br />

• All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.<br />

• For most jobs, about 400 CFM per ton when cooling is desirable.<br />

• Operation is recommended below .5” w.c. ESP in heating mode.<br />

Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.<br />

8 www.amana-hac.com SS-<strong>AMVM96</strong>


Product Specifications<br />

<strong>ACVM96</strong> Airflow Data (cont.)<br />

Tap<br />

A<br />

B<br />

C<br />

D<br />

Adjust<br />

<strong>ACVM96</strong>1005DX<br />

Cooling Speed<br />

(@ .1˝ - .8˝ w.c. ESP)<br />

High-Stage<br />

CFM<br />

Low-Stage<br />

CFM<br />

Tap<br />

<strong>ACVM96</strong>1005DX<br />

Heating Speed<br />

(@ .1˝ - .5˝ w.c. ESP; Rise Range: 25 - 55°F)<br />

Adjust<br />

High-Stage<br />

CFM<br />

Minus 10% 702 450<br />

Minus 10% 1,557 56<br />

A<br />

Normal 780 500 Normal 1,730 51<br />

Plus 10% 858 550 Plus 10% 1,903 46<br />

Minus 10% 963 666<br />

Minus 10% 1,593 55<br />

Normal 1070 740 B Normal 1,770 49<br />

Plus 10% 1177 814 Plus 10% 1,947 45<br />

Minus 10% 1242 828<br />

Minus 10% 1,656 53<br />

Normal 1380 920 C Normal 1,840 48<br />

Plus 10% 1518 1012 Plus 10% 2,024 43<br />

Minus 10% 1602 1044<br />

Minus 10% 1,683 52<br />

Normal 1780 1160 D Normal 1,870 47<br />

Plus 10% 1958 1276 Plus 10% 2,057 43<br />

Rise<br />

(°F)<br />

Notes<br />

• All furnaces ship as high speed for cooling. Installer must adjust blower<br />

speed as needed.<br />

• For most jobs, about 400 CFM per ton when cooling is desirable.<br />

• Operation is recommended below .5” w.c. ESP in heating mode. Operating<br />

CFM between .5” and .8” w.c. is tabulated for cooling purposes only.<br />

• 100% CFM shown. CFM will vary proportionally with the gas valve BTU/H input.<br />

SS-<strong>AMVM96</strong> www.amana-hac.com 9


Product Specifications<br />

Temperature Rise Range Chart<br />

100<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

BTU BTU/h OUTPUT Output vs TEMPERATURE Vs. Temperature RISE Rise Chart CHART<br />

600 CFM<br />

700<br />

800<br />

900<br />

1000<br />

1100<br />

1200<br />

1400<br />

1600<br />

1800<br />

2000<br />

2200<br />

2400 CFM<br />

FORMULAS<br />

BTU BTU/h OUTPUT Output = = CFM x 1.08 x x Rise RISE<br />

RISE<br />

Rise<br />

=<br />

=<br />

Formulas<br />

BTU OUTPUT<br />

BTU/H Output<br />

1.08<br />

CFM x 1.08<br />

÷ CFM<br />

30 40 50 60 70 80 90 100 110 120 130 140 150<br />

OUTPUT Output BTU/h BTU/HR x 1,000 x 1000<br />

TEMPERATURE Temperature Rise RISE<br />

10 www.amana-hac.com SS-<strong>AMVM96</strong>


4<br />

3<br />

2<br />

1<br />

7<br />

4<br />

1<br />

8<br />

5<br />

2<br />

9<br />

6<br />

3<br />

2<br />

1<br />

Product Specifications<br />

Wiring Diagram<br />

WH<br />

WH<br />

HOT<br />

SURFACE<br />

IGNITER<br />

2<br />

WH<br />

1<br />

RD<br />

WH<br />

2 CIRCUIT<br />

CONNECTOR<br />

MODULATING<br />

GAS VALVE<br />

(HONEY WELL)<br />

PU<br />

WH<br />

RD<br />

BLOWER COMPARTMENT<br />

AUTO RESET<br />

AUXILIARY<br />

LIMIT CONTROL<br />

BK<br />

PU<br />

FLAME<br />

SENSOR<br />

COOL TAPS<br />

1<br />

RAMPING<br />

1<br />

2<br />

3<br />

COOL SETUP<br />

HEAT SETUP<br />

2<br />

DEHUM<br />

ECM MTR<br />

HARNESS BK BL<br />

RD GY<br />

3<br />

3<br />

2<br />

1<br />

HEAT TAPS<br />

ID BLOWER<br />

CONNECTOR<br />

ADJUST<br />

FUSE<br />

LOW FIRE<br />

PRESSURE<br />

SWITCH<br />

BL<br />

DIAGNOSTIC<br />

LED'S<br />

DELAY<br />

PULL DOWN<br />

PULL UP<br />

BIAS<br />

24 V 3A<br />

4<br />

FAN TAPS<br />

OR<br />

WH<br />

2<br />

5<br />

4<br />

3<br />

2<br />

1<br />

R<br />

BR<br />

GY<br />

C<br />

C<br />

PK<br />

G<br />

GY<br />

W1<br />

BK<br />

WH<br />

GR<br />

NOTES:<br />

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.<br />

2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE<br />

USED WHEN SERVICING.<br />

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE<br />

FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH<br />

WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT<br />

LEAST 105°C. USE COPPER CONDUCTORS ONLY.<br />

4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO<br />

N.E.C. AND LOCAL CODES.<br />

5. TO RECALL THE LAST 10 FAULTS, MOST RECENT TO LEAST<br />

RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS<br />

WHILE IN STANDBY (NO THERMOSTAT INPUTS)<br />

C<br />

PM<br />

HEAT OFF<br />

RD<br />

BK<br />

24V HUM.<br />

1<br />

DIP SWITCHES<br />

BR<br />

AUTO RESET PRIMARY<br />

LIMIT CONTROL<br />

BURNER COMPARTMENT<br />

CIRCULATOR BLOWER<br />

MODULATING INTERGRATED<br />

FURNACE CONTROL MODULE<br />

OR<br />

PK<br />

ID BLOWER TWO-STAGE PRESSURE<br />

SWITCH ASSEMBLY<br />

NO<br />

NO<br />

W2<br />

OR<br />

Y1<br />

WH<br />

Y2<br />

OR<br />

PU<br />

O<br />

LINE<br />

HSI<br />

EAC<br />

HUM<br />

DEHUM<br />

BR<br />

10<br />

11<br />

12<br />

AUX<br />

NEUTRAL<br />

OR<br />

OR<br />

NO<br />

GY<br />

FRONT COVER<br />

PRESSURE SWITCH<br />

GND<br />

OR<br />

YL<br />

MANUAL RESET ROLLOUT LIMIT CONTROLS<br />

(SINGLE CONTROL ON 45 kBTU)<br />

24 V THERMOSTAT CONNECTIONS<br />

C<br />

GND<br />

YL<br />

C<br />

INDUCED<br />

DRAFT<br />

BLOWER<br />

RD<br />

RD<br />

OR<br />

OR<br />

BK GY<br />

BK<br />

BL<br />

INDUCTOR COIL<br />

70kBTU,90kBTU,<br />

115kBTU MODELS<br />

ONLY<br />

0140F01166-A<br />

BK<br />

HIGH FIRE<br />

PRESSURE<br />

SWITCH<br />

PU<br />

BR<br />

BR<br />

YL<br />

COLOR CODES:<br />

PK PINK<br />

BR BROWN<br />

WH WHITE<br />

BL BLUE<br />

GY GRAY<br />

RD RED<br />

YL YELLOW<br />

OR ORANGE<br />

PU PURPLE<br />

GR GREEN<br />

BK BLACK<br />

FLAME<br />

SENSOR<br />

BK<br />

WH<br />

BL<br />

40 VA<br />

TRANSFORMER<br />

GR<br />

24<br />

VAC<br />

115<br />

VAC<br />

WH<br />

CHASSIS<br />

GROUND<br />

JUNCTION BOX<br />

GY<br />

BK<br />

BK<br />

BLOWER<br />

COMPARTMENT<br />

DOOR SWITCH<br />

(OPEN WHEN<br />

DOOR OPEN)<br />

JUNCTION<br />

TERMINAL<br />

WH<br />

WARNING:<br />

DISCONNECT POWER<br />

BEFORE SERVICING<br />

WIRING TO UNIT<br />

MUST BE PROPERLY<br />

POLARIZED AND<br />

GROUNDED.<br />

INTEGRATED CONTROL MODULE 24V THERMOSTAT CONNECTIONS<br />

24V HUM.<br />

R<br />

Y1<br />

W1<br />

W2<br />

Y2<br />

G<br />

O<br />

DEHUM<br />

C<br />

TO<br />

R<br />

DISCONNECT<br />

DOOR<br />

SWITCH<br />

INDUCTOR COIL<br />

70kBTU,90kBTU,<br />

115kBTU MODELS<br />

ONLY<br />

LINE<br />

TO<br />

MICRO<br />

LINE<br />

EAC<br />

HUM<br />

IGN<br />

FS<br />

3<br />

2<br />

1<br />

(2)<br />

(7)<br />

(10)<br />

FLAME<br />

SENSOR<br />

INTEGRATED CONTROL<br />

MODULE<br />

HUMIDIFIER<br />

OPTIONAL<br />

L<br />

WARNING:DISCONNECT<br />

POWER BEFORE SERVICING<br />

N WIRING. TO UNIT MUST BE<br />

PROPERLY POLARIZED<br />

AND GROUNDED.<br />

INDOOR<br />

AIR<br />

CIRCULATOR<br />

BLWR<br />

115<br />

VAC<br />

GND<br />

NO<br />

FIELD GND<br />

GND<br />

NEUTRAL<br />

40 VA<br />

FUSE 3A TR (5)<br />

TRANSFORMER<br />

24 VAC AUTO RESET PRIMARY<br />

AUTO RESET AUXILIARY LIMIT LIMIT CONTROL<br />

TO+VDC CONTROLS<br />

(3)<br />

TO<br />

MICRO<br />

LOW VOLTAGE FIELD<br />

LOW VOLTAGE (24V)<br />

HI VOLTAGE (115V)<br />

HI VOLTAGE FIELD<br />

INTERNAL TO<br />

INTEGRATED CONTROL<br />

PLUG CONNECTION<br />

(6)<br />

(12)<br />

(11)<br />

(8)<br />

GND (4)<br />

TR (9)<br />

ELECTRONIC<br />

AIR CLEANER<br />

OPTIONAL<br />

NO<br />

JUNCTION BOX<br />

3Ø ID<br />

BLWR<br />

HUMIDIFIER<br />

OPTIONAL<br />

HIGH FIRE<br />

PRESS. SWITCH<br />

GND (4)<br />

+ VDC (1)<br />

RX (2)<br />

TX (3)<br />

TO<br />

GND 115 VAC/1 Ø /60 HZ<br />

POWER SUPPLY WITH<br />

OVERCURRENT<br />

PROTECTION<br />

L DEVICE<br />

TO 115VAC/1 Ø /60 HZ POWER SUPPLY WITH<br />

OVERCURRENT PROTECTION DEVICE<br />

HOT SURFACE<br />

IGNITER<br />

C<br />

GND<br />

NO<br />

IGNITER<br />

C<br />

N<br />

INDOOR<br />

AIR<br />

CIRCULATOR<br />

BLWR<br />

EQUIPMENT GND<br />

FIELD SPLICE<br />

SWITCH (TEMP)<br />

OVERCURRENT<br />

PROT. DEVICE<br />

TO UNIT MUST BE<br />

DISCONNECT<br />

NEUTRAL<br />

NEUTRAL<br />

NEUTRAL<br />

NEUTRAL<br />

SWITCH PRESSURE<br />

LOW FIRE<br />

PRESS.<br />

SWITCH<br />

C<br />

MANUAL RESET ROLLOUT<br />

LIMIT CONTROLS<br />

FRONT COVER<br />

PRESS.<br />

SWITCH<br />

PM<br />

C<br />

GAS<br />

VALVE<br />

INTEGRATED CONTROL MODULE<br />

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power<br />

sources may be present. Failure to do so may cause property damage, personal injury, or death. ⚡<br />

Wiring is subject to change. Always<br />

refer to the wiring diagram or the ⚠ Warning<br />

unit for the most up-to-date wiring.<br />

SS-<strong>AMVM96</strong> www.amana-hac.com 11


Product Specifications<br />

Thermostats<br />

CTK03 ComfortNet-compatible Control<br />

(See ComfortNet website (www.comfortnet1.com) for details.)<br />

CTK02 ComfortNet-compatible Control<br />

(See ComfortNet website (www.comfortnet1.com) for details.)<br />

CTK01 ComfortNet-compatible Control<br />

(See ComfortNet website (www.comfortnet1.com) for details.)<br />

Accessories<br />

Model<br />

LPKM0D060UF<br />

Description<br />

<strong>AMVM96</strong><br />

0603BX<br />

<strong>AMVM96</strong><br />

0805CX<br />

<strong>AMVM96</strong><br />

1005DX<br />

<strong>AMVM96</strong><br />

1155DX<br />

<strong>ACVM96</strong><br />

0604CX<br />

LPKM0D100UF --- --- √ --- --- ---<br />

LP Conversion Kits<br />

LPKM0D115UF --- --- --- √ --- ---<br />

<strong>ACVM96</strong><br />

0805DX<br />

√ --- --- --- --- ---<br />

LPKM0D080UF --- √ --- --- --- ---<br />

LPKM0D060CF --- --- --- --- √ ---<br />

LPKM0D080CF --- --- --- --- --- √<br />

EFR01 External Filter Rack √ √ √ √ √ √<br />

DCVK-20 Horizontal/Vertical Concentric Vent Kit (2”) √ √ √ --- √ ---<br />

DCVK-30 Horizontal/Vertical Concentric Vent Kit (3”) √ √ √ √ √ √<br />

CFB21 Downflow Floor Base --- --- --- --- √ ---<br />

CFB24 Downflow Floor Base --- --- --- --- --- √<br />

0170K00000S Flush-mount vent kit √ √ √ √ √ √<br />

Notes<br />

√ Indicates available for this model<br />

• For installation in Canada, gas furnaces are certified only to 4,500’.<br />

<strong>Amana</strong>® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing<br />

commitment to quality products may mean a change in specifications without notice. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.<br />

12 www.amana-hac.com SS-<strong>AMVM96</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!