<strong>UniAlert</strong> <strong>GSM</strong>


Table of Contents<br />

1. Application Overview________________________________________________________ 1<br />

1.1. Identifying the Parts _______________________________________________________________ 1<br />

1.2. In<strong>se</strong>rt <strong>GSM</strong> SIM Card _____________________________________________________________ 2<br />

1.3. The Power Supply ________________________________________________________________ 3<br />

1.4. Input/Output & DC Terminals ______________________________________________________ 3<br />

1.5. How to install the <strong>UniAlert</strong> _________________________________________________________ 4<br />

1.6. Two-Level Passwords ______________________________________________________________ 4<br />

1.7. Getting Started ___________________________________________________________________ 4<br />

2. Configuring Your System ____________________________________________________ 5<br />

2.1. Entering Programming Mode _______________________________________________________ 6<br />

2.2. Telephone Settings ________________________________________________________________ 6<br />

2.3. PIN Code ________________________________________________________________________ 7<br />

2.4. Master Code _____________________________________________________________________ 7<br />

2.5. Entry Time ______________________________________________________________________ 8<br />

2.6. Exit Time ________________________________________________________________________ 8<br />

2.7. Alarm Length ____________________________________________________________________ 8<br />

2.8. Internal Siren ____________________________________________________________________ 9<br />

2.8. Add/Remove Device _______________________________________________________________ 9<br />

2.8.1. Add Devices _______________________________________________________________________ 10<br />

2.8.2. Remove Devices ___________________________________________________________________ 10<br />

2.9. Program Siren __________________________________________________________________ 11<br />

2.10. Remote Programming via SMS Commands _________________________________________ 12<br />

2.10.1. SMS Program Word (P-Word)_______________________________________________________ 13<br />

2.10.2. SMS Keyword _____________________________________________________________________ 13<br />

2.10.3. SMS Header_______________________________________________________________________ 13<br />

2.11. Walk Test (Local Programming Only) ______________________________________________ 13<br />

2.12. Exiting Programming Mode ______________________________________________________ 14<br />

3. Operation _________________________________________________________________ 14<br />

3.1. Away (Alarm On) Mode __________________________________________________________ 15<br />

3.2. Disarm (Alarm Off) Mode _________________________________________________________ 15<br />

3.3. Stop the Alarm __________________________________________________________________ 15<br />

3.4. Dual-Key Function _______________________________________________________________ 16<br />

1


3.5. Faulty Situations _________________________________________________________________ 16<br />

3.6. Remote Commanding (SMS Only) __________________________________________________ 17<br />

3.7. Message Composition _____________________________________________________________ 17<br />

3.8. Programming Command Table ____________________________________________________ 18<br />

4. Appendix __________________________________________________________________ 20<br />

4.1. Re<strong>se</strong>t Procedure _______________________________________________________________ 20<br />

4.2. Event Code ____________________________________________________________________ 21<br />

2


1. Application Overview<br />

1.1. Identifying the Parts<br />

— FLASH SYNCHRONOUSLY WITH<br />

GREEN LED: Walk Test<br />

— QUICK FLASH FOR 1.6 SEC: PIR<br />

trigger<br />

4<br />

Numeric Keys<br />

1<br />

2<br />

Internal PIR Detector<br />

Green LED<br />

— ON: Power On<br />

— FLASH (1s On / 1s Off): <strong>GSM</strong> fault<br />

— SLOW FLASH (60ms On / 2.5s Off):<br />

<strong>UniAlert</strong> Tamper fault or Low Battery<br />

or AC fault<br />

— QUICK FLASH (60ms On / 500ms<br />

Off): Device Tamper fault or Low<br />

Battery<br />

— FLASH ALTERNATELY WITH RED<br />

LED: Programming mode<br />

— FLASH SYNCHRONOUSLY WITH<br />

RED LED: Walk Test<br />

— QUICK FLASH FOR 1.6 SEC: RF<br />

transmitting<br />

5<br />

<br />

6<br />

— The<strong>se</strong> buttons are u<strong>se</strong>d to enter<br />

numbers.<br />

Disarm Key<br />

— Enter PIN Code and press once to<br />

disarm the system<br />

— Enter Master Code and press twice to<br />

enter Programm mode (in Disarm<br />

mode only).<br />

— The <strong>se</strong>cond Disarm key must be<br />

pres<strong>se</strong>d within 0.5 <strong>se</strong>conds.<br />

Arm Key<br />

— Enter PIN Code and press once to<br />

arm the system<br />

— In Programming mode, u<strong>se</strong> this key to<br />

abort<br />

<br />

Green LED’s indicating priority<br />

<strong>se</strong>quence is Programming mode > RF<br />

transmitting > <strong>GSM</strong> fault > <strong>UniAlert</strong><br />

fault > Device Fault.<br />

3<br />

Red LED<br />

— ON: Arm mode<br />

— FLASH: Alarm<br />

— FLASH ALTERNATELY WITH<br />

GREEN LED: Programming mode<br />

7<br />

8<br />

Buzzer<br />

Battery Switch<br />

1


1.2. In<strong>se</strong>rt <strong>GSM</strong> SIM Card<br />

9<br />

External <strong>GSM</strong> Antenna Jumper<br />

Swich (JP2)<br />

Jumper On<br />

The jumper link is in<strong>se</strong>rted<br />

connecting the two pins.<br />

Jumper Off<br />

The jumper link is removed<br />

or “parked” on one pin.<br />

— Jumper ON: External antenna disable<br />

(default)<br />

<strong>UniAlert</strong> features built-in <strong>GSM</strong> communication<br />

facility to make message reporting to the<br />

phone numbers pre-programmed within the<br />

system.<br />

To In<strong>se</strong>rt your SIM card:<br />

The <strong>GSM</strong> component is situated inside the<br />

Power Supply compartment as pointed out by<br />

the arrow below:<br />

— Jumper OFF: External antenna enable<br />

Internal PIR Detector Jumper<br />

Switch (JP1)<br />

— Jumper ON: Internal PIR enable<br />

(default)<br />

— Jumper OFF: Internal PIR disable<br />

Input/Output Contact Point & DC<br />

Terminals (refer to <strong>se</strong>ction 1.4)<br />

<strong>GSM</strong> SIM Card Ba<strong>se</strong><br />

<strong>GSM</strong> LED<br />

— SLOW FLASH (300ms On / 3.0s Off):<br />

Normal operation<br />

— QUICK FLASH (500ms On / 500ms<br />

Off): Searching for <strong>GSM</strong> reception/<br />

<strong>GSM</strong> fault<br />

<strong>GSM</strong> Antenna<br />

— For connecting an external <strong>GSM</strong><br />

antenna<br />

Mounting Holes<br />

Power Supply Compartment Cover<br />

Wall Mounting Bracket<br />

• Unlock the SIM card ba<strong>se</strong> by sliding the<br />

cover toward OPEN-backward direction.<br />

• Spring open the SIM card slot and in<strong>se</strong>rt<br />

your new SIM card.<br />

• Replace the SIM slot onto the ba<strong>se</strong> lightly.<br />

• Remember to lock the SIM card ba<strong>se</strong> by<br />

sliding the cover toward LOCK-forward<br />

direction.<br />

<br />

Beware to only in<strong>se</strong>rt or remove SIM<br />

card when <strong>UniAlert</strong> is completely<br />

depleted of any power residual.<br />

Plea<strong>se</strong> ensure the SIM card’s PIN<br />

code is disabled before in<strong>se</strong>rting into<br />

the <strong>UniAlert</strong>.<br />

2


1.3. The Power Supply<br />

A DC Terminal is eqipped to connect to a 12V<br />

power source.<br />

Rechargeable Battery<br />

• In addition to the DC power source,<br />

there is a rechargeable battery inside<br />

the <strong>UniAlert</strong> that <strong>se</strong>rves as a back up<br />

in ca<strong>se</strong> of power failure.<br />

• The battery u<strong>se</strong>d is a 4.8V 600mAH<br />

Ni-mH rechargeable battery pack.<br />

• During normal operation, the DC<br />

power source is u<strong>se</strong>d to supply power<br />

to the <strong>UniAlert</strong> and at the same time<br />

recharge the battery.<br />

• When the battery is fully charged, it<br />

can provide back-up power for a<br />

period of at least 6 hours. It takes<br />

approximately 48 hours to fully charge<br />

the battery.<br />

1.4. Input/Output & DC<br />

Terminals<br />

Connect the DC power and wired devices to<br />

the input/output contact points as shown below.<br />

Pins 5 & 6 DC 12V Power Output<br />

• A DC 12V 100mA Power Output Terminal<br />

is available to supply power to other wired<br />

devices if required.<br />

Pins 7 & 8 Arm/Disarm Input<br />

• For the wired device connected to<br />

Arm/Disarm Input Terminal:<br />

<br />

• The system enters Arm mode when<br />

the circuit is short.<br />

• The system enters Disarm mode<br />

when the circuit is open.<br />

Exit Timer is ineffective if the system<br />

is armed via this device. That is, the<br />

<strong>UniAlert</strong> enters Arm mode immediately<br />

when the circuit is short.<br />

Pins 9 & 10 Alarm Output (N.O.)<br />

• When an alarm is triggered, the device<br />

connected to Alarm Output will change<br />

the status from open to short (activate),<br />

until Alarm Length time is expired or when<br />

the <strong>UniAlert</strong> is disarmed. Then the status<br />

will change from short to open (deactivate)<br />

again.<br />

<br />

Alarm Output will not respond if Alarm<br />

Length is <strong>se</strong>t as 00 (disable).<br />

Pins 1 & 2 DC 12V Power Input<br />

• Connect a DC 12V power source to the<br />

Power Input Terminal.<br />

Pins 3 & 4 Alarm Input (N.C.)<br />

• When a wired <strong>se</strong>nsor/device is connected<br />

to the Alarm Input Terminal, the alarm will<br />

be triggered and a report will be <strong>se</strong>nt to<br />

the Central Monitoring Station when either<br />

the built-in PIR detector or this wired<br />

<strong>se</strong>nsor is triggered.<br />

3


1.5. How to install the <strong>UniAlert</strong><br />

Locating a suitable position for the<br />

<strong>UniAlert</strong><br />

• The <strong>UniAlert</strong> requires DC power and a<br />

constant <strong>GSM</strong> reception.<br />

• The <strong>UniAlert</strong> should be easily accessible,<br />

• The <strong>UniAlert</strong> should not be placed in a<br />

damp place, such as a bathroom.<br />

• The <strong>UniAlert</strong> should not be placed clo<strong>se</strong><br />

to any heat source, such as microwave<br />

ovens, which can reduce signal srength.<br />

• The <strong>UniAlert</strong> should not be located<br />

alongside other radio transmitting devices<br />

such as mobile phones, cordless phone or<br />

wireless computer network (WiFi) devices.<br />

Impontant: When drilling into a wall, ensure<br />

that there are no hidden cables or pipes.<br />

Mounting the <strong>UniAlert</strong><br />

The <strong>UniAlert</strong> is to be mounted on the wall. It is<br />

recommended to install the <strong>UniAlert</strong><br />

approximately 1.8 meters above ground level<br />

(top edge). The detection range is 10 meters at<br />

90° angle.<br />

In order to provide highest <strong>se</strong>curity in operating<br />

the system, <strong>UniAlert</strong> offers 2 levels of<br />

authorization. To program the system, you<br />

must enter Master Code.<br />

PIN Code<br />

• There are a total of 4 U<strong>se</strong>r PIN codes in<br />

the system. The PIN code is the 1st level<br />

of password.<br />

• U<strong>se</strong>r 1 PIN code cannot be deleted in<br />

any way.<br />

• 1234 is <strong>se</strong>t as default U<strong>se</strong>r 1 PIN code by<br />

the factory.<br />

• U<strong>se</strong>r 2 to 4 PIN codes are deactivated by<br />

factory default.<br />

<br />

U<strong>se</strong>r PIN codes may not be identical.<br />

If you <strong>se</strong>t the same number, the unit<br />

will emit 4 short beeps to alert the u<strong>se</strong>r.<br />

Master Code<br />

• The Master Code has the authorization to<br />

enter Programming mode and cannot be<br />

deleted in anyway.<br />

• 1111 is <strong>se</strong>t as default Master Code by the<br />

factory.<br />

<br />

Master Code and U<strong>se</strong>r PIN code may<br />

be the same.<br />

• Using the 2 holes of the wall mounting<br />

bracket as a template, mark off the holes’<br />

positions.<br />

• Drill 2 holes and in<strong>se</strong>rt the wall plugs if<br />

fixing into plaster or brick.<br />

• Hook the <strong>UniAlert</strong> onto the wall mounting<br />

bracket.<br />

1.6. Two-Level Passwords<br />

1.7. Getting Started<br />

4


Step 1. Find a suitable location for the<br />

<strong>UniAlert</strong> to be installed.<br />

Step 2. Apply power, and you will hear 2<br />

beeps. Plea<strong>se</strong> wait for approximately<br />

2 minutes for the system to <strong>se</strong>arch for<br />

a <strong>GSM</strong> reception; the Green LED<br />

flashes.<br />

Step 3. Wait for about a minute. When a <strong>GSM</strong><br />

reception is found, the Green LED<br />

becomes steadily on and the <strong>GSM</strong><br />

LED is flashes slowly (300ms On /<br />

3.0s Off). The system is now in<br />

Disarm mode.<br />

<br />

If after a few minutes, the Green LED<br />

(1s On / 1s Off) and the <strong>GSM</strong> LED<br />

(500ms On / 500ms Off) are still<br />

flashing, it means <strong>GSM</strong> activation has<br />

failed. Plea<strong>se</strong> check if the SIM card is<br />

properly in<strong>se</strong>rted and <strong>GSM</strong> reception<br />

is available.<br />

5<br />

2. Configuring Your


System<br />

2.1. Entering Programming<br />

Mode<br />

When the system is in Disarm mode, to enter<br />

the Programming mode, follow the steps below.<br />

Step 1. Enter the Master Code (1111 is <strong>se</strong>t as<br />

factory default).<br />

Step 2. Press the<br />

<br />

Disarm key twice.<br />

The <strong>se</strong>cond Disarm key must be<br />

pres<strong>se</strong>d within 0.5 <strong>se</strong>cond.<br />

Step 3. When successfully entered<br />

Programming mode, the Green & Red<br />

LED will flash alternately.<br />

Step 4. Start by pressing the Disarm key,<br />

followed by the programming<br />

command then the new <strong>se</strong>tting, and<br />

end with the Disarm key (plea<strong>se</strong><br />

refer to <strong>se</strong>ction 3.8 Programmig<br />

Command Table for more details).<br />

<br />

To change Master Code to 2222, enter:<br />

“ 102222 ”<br />

Where:<br />

10 = Command to <strong>se</strong>t Master Code<br />

2222 = new Master Code<br />

Step 5. 2 beeps will be heard to confirm the<br />

new <strong>se</strong>tting is accepted and stored.<br />

On the other hand, 4 beeps will be<br />

heard to indicate the new <strong>se</strong>tting is<br />

errounous or unacceptable.<br />

<br />

After Master code is programmed with<br />

new a number, plea<strong>se</strong> be reminded to<br />

enter the new number when<br />

accessing Programming mode<br />

afterwards.<br />

In Programming mode, press the<br />

Arm key at any time to abort.<br />

In Programming mode, if no key is<br />

pres<strong>se</strong>d within 3 minutes, the <strong>UniAlert</strong><br />

will automatically exit Programming<br />

mode to Disarm mode.<br />

If reporting or SMS remote<br />

programming is in progress, then 8<br />

beeps will be heard to alert the u<strong>se</strong>r<br />

that entering Programming mode is<br />

prohibited at the moment.<br />

2.2. Telephone Settings<br />

• This allows you to <strong>se</strong>t/change/delete the<br />

Central Monitoring Station or mobile<br />

telephone numbers for reporting purpo<strong>se</strong>.<br />

• A maximum of four numbers can be stored<br />

in priority order (in the order of 1, 2, 3, then<br />

4).<br />

<br />

At least one phone number must be<br />

entered, or the <strong>UniAlert</strong> will not dial out<br />

at alarm situations.<br />

Store/Change Tel. Numbers<br />

U<strong>se</strong> command 31 for Tel. Number 1, command<br />

32 for Tel. Number 2, and so on up to<br />

command 34 for Tel Number 4. The maximum<br />

length of a number is 20 digits.<br />

• To <strong>se</strong>nd SMS text message to u<strong>se</strong>r’s<br />

mobile phone, usage as below:<br />

3100267890001<br />

3200267890001<br />

3300267890001<br />

3400267890001<br />

Where:<br />

0 = SMS Text Message<br />

0267890001 = Telephone number<br />

<br />

All Alarm & Fault events will be<br />

reported to all numbers that are <strong>se</strong>t as<br />

0 (SMS Text Message).<br />

• To <strong>se</strong>nd SMS Contact ID (SCID) to Central<br />

Monitoring Station, usage as below:<br />

Where:<br />

31422220267890001<br />

32422220267890001<br />

33422220267890001<br />

34422220267890001<br />

6


4 = SMS Contact ID (SCID)<br />

2222 = Account number<br />

0267890001 = Telephone number<br />

<br />

Tel Numbers that are <strong>se</strong>t as 4 (SCID)<br />

have higher dialing priority than Tel<br />

numbers that are <strong>se</strong>t as 0 (SMS Text<br />

Message).<br />

<strong>UniAlert</strong> will dial the Tel Numbers for<br />

SMS Text Message after the Tel<br />

Numbers for SCID are finished.<br />

The reach number of SCID report is<br />

defined by Programming command 39.<br />

Delete Tel. Numbers<br />

To delete a telephone number, enter the<br />

respective command (e.g. 31 for Tel. Number<br />

1, 32 for Tel. Number 2) with null <strong>se</strong>tting.<br />

<br />

To delete Tel. Number 1, enter:<br />

“ 31 ”<br />

Set SCID Reach Number<br />

This is for you to <strong>se</strong>t how many Central Station<br />

Receivers should the <strong>UniAlert</strong>’s SCID reporting.<br />

Options available are One of TEL1-4 and All<br />

of TEL1-4.<br />

If you choo<strong>se</strong> One of TEL1-4, the <strong>UniAlert</strong> will<br />

try to dial the first SCID Tel number. If it failed,<br />

the <strong>UniAlert</strong> will try the next SCID Tel number.<br />

As long as one SCID Tel number is<br />

successfully reported, then the job is done.<br />

If you choo<strong>se</strong> All of TEL1-4, the <strong>UniAlert</strong> will<br />

need to successfully report to all of the SCID<br />

Tel numbers.<br />

U<strong>se</strong> command 39 with option 0 for One of<br />

TEL1-4 (if <strong>se</strong>t as SCID), and option 1 for All of<br />

TEL1-4 (if <strong>se</strong>t as SCID). Usage as below:<br />

390<br />

391<br />

Where:<br />

0 = One of TEL1-4 (if <strong>se</strong>t as SCID)<br />

1 = All of TEL1-4 (if <strong>se</strong>t as SCID)<br />

All of TEL1-4 is <strong>se</strong>t as factory default.<br />

2.3. PIN Code<br />

• There are 4 U<strong>se</strong>r PIN codes in total, and<br />

each consists of 4 digits. U<strong>se</strong>r 1 PIN code<br />

is activated as 1234 by factory default and<br />

cannot be deleted in any way.<br />

• U<strong>se</strong>r 2 to 4 PIN codes are deactivated by<br />

factory default.<br />

• All 4 U<strong>se</strong>r PIN codes are u<strong>se</strong>d to regularly<br />

arm/disarm the system.<br />

To Set/Change Own U<strong>se</strong>r PIN Code<br />

PIN codes can be re<strong>se</strong>t/changed by using the<br />

commands 11 to 14 to change the respective<br />

U<strong>se</strong>r PIN codes #1-4. Usage as below:<br />

Where:<br />

0 = Latch Report Off<br />

1 = Latch Report On<br />

1112340 (Latch Off)<br />

:<br />

1443211 (Latch On)<br />

U<strong>se</strong>r 1 PIN 1234 Latch Off is <strong>se</strong>t as factory<br />

default.<br />

<br />

Latch Report ON = Whenever the<br />

system is armed or disarmed, the<br />

<strong>UniAlert</strong> will <strong>se</strong>nd Contact ID code via<br />

SMS to notify the Central Monitoring<br />

Station, or SMS Text Message to<br />

u<strong>se</strong>r’s mobile phone (according to the<br />

Tel. <strong>se</strong>tting).<br />

Latch Reprot OFF = Whenever the<br />

system is armed or disarmed, the<br />

<strong>UniAlert</strong> will NOT <strong>se</strong>nd reporting(s) to<br />

notify the Central Monitoring Station<br />

nor the u<strong>se</strong>r.<br />

To Delete U<strong>se</strong>r PIN Code<br />

Except U<strong>se</strong>r 1 PIN code which is activated by<br />

factory default and can’t be deleted in any way,<br />

U<strong>se</strong>r PIN code 2, 3 and 4 can be deleted by<br />

enter the respective command (e.g. 12 for U<strong>se</strong>r<br />

2 PIN code, 13 for Tel. Number 2) with null<br />

<strong>se</strong>tting.<br />

<br />

To delete U<strong>se</strong>r 2 PIN code, enter:<br />

“ 12 ”<br />

2.4. Master Code<br />

7


• Master Code is u<strong>se</strong>d for accessing the<br />

Programming mode and it is <strong>se</strong>t as 1111 by<br />

factory default.<br />

• The Master code can not be deleted in<br />

anyway (same as the U<strong>se</strong>r 1 PIN code).<br />

• The Master Code is u<strong>se</strong>d to enter<br />

Programming mode only. In other ca<strong>se</strong>s,<br />

only U<strong>se</strong>r PIN code should be entered.<br />

• U<strong>se</strong> command 10 to <strong>se</strong>t/change own<br />

Master Code. Usage as below:<br />

101111<br />

1111 is <strong>se</strong>t as factory default.<br />

2.5. Entry Time<br />

The system goes into counting down period<br />

(away entry timer) when the PIR is triggered<br />

under Arm mode.<br />

During the counting down period, it is allowed<br />

to u<strong>se</strong> correct PIN code to disarm the alarm<br />

and the alarm reporting will not be <strong>se</strong>nt. On the<br />

other hand, if the correct PIN code has not<br />

been entered within the period, <strong>UniAlert</strong> rai<strong>se</strong>s<br />

an alarm and <strong>se</strong>nds an alarm report.<br />

To <strong>se</strong>t/change Entry Timer, u<strong>se</strong> command 22<br />

with options of 00 (alarm immediately), 01 (1<br />

<strong>se</strong>c), 02 (2 <strong>se</strong>c)…up to 70 (70 <strong>se</strong>c). Usage as<br />

below:<br />

2200<br />

2270<br />

Where:<br />

00 = 0 <strong>se</strong>c (alarm immediately)<br />

70 = 70 (70 <strong>se</strong>cs)<br />

30 <strong>se</strong>c is <strong>se</strong>t as factory default.<br />

<strong>UniAlert</strong>, Remote Controller (RC) or Remote<br />

Keypad (KP), an Away exit timer starts<br />

counting down.<br />

During the counting down period, pressing the<br />

Arm Button of the RC can restart the counting.<br />

In addition, it is allowed to u<strong>se</strong> correct PIN<br />

code or press Disarm Button of the RC to stop<br />

the counting and return to Disarm mode.<br />

To <strong>se</strong>t/change Exit Timer, u<strong>se</strong> command 23<br />

with options of 00 (alarm immediately), 01 (1<br />

<strong>se</strong>c), 02 (2 <strong>se</strong>c)…up to 70 (70 <strong>se</strong>c). Usage as<br />

below:<br />

2300<br />

2370<br />

Where:<br />

00 = 0 <strong>se</strong>c (arm immediately)<br />

70 = 70 (70 <strong>se</strong>cs)<br />

30 <strong>se</strong>c is <strong>se</strong>t as factory default.<br />

<br />

Exit Timer is ineffective if the<br />

Home/Partial Arm Button of the RC is<br />

pres<strong>se</strong>d. That is, the <strong>UniAlert</strong> enters<br />

Arm mode immediately when the<br />

Home/Partial Arm Button of the RC is<br />

pres<strong>se</strong>d.<br />

2.6. Exit Time<br />

While the system gets into Arm mode by<br />

8<br />

2.7. Alarm Length<br />

This is for you to <strong>se</strong>lect the internal siren


duration when an alarm is activated.<br />

To <strong>se</strong>t/change Alarm Length, u<strong>se</strong> command 21<br />

with options of 00 (disable), 01 (1 min), up to<br />

15 (15 mins) in 1-min increments. Usage as<br />

below:<br />

Where:<br />

00 = Disable<br />

15 = 15 minutes<br />

2100<br />

2115<br />

3 min is <strong>se</strong>t as factory default.<br />

• If Disable is <strong>se</strong>lected, when <strong>UniAlert</strong><br />

receives an alarm signal, the internal siren<br />

and external sirens (SR & BX) will not rai<strong>se</strong><br />

an alarm sound. Alarm Output is also<br />

disabled.<br />

• When a 2 nd alarm is triggered during the<br />

Alarm Length period, Alarm Length will not<br />

be extended/incremented.<br />

• If SR/BX’s alarm length is longer than the<br />

<strong>UniAlert</strong>’s, the system gives priority to the<br />

<strong>UniAlert</strong> (e.g. when the SR/BX’s alarm<br />

length is <strong>se</strong>t as 3 mins, and the <strong>UniAlert</strong>’s<br />

alarm length is <strong>se</strong>t as 1 min, both alarm<br />

siren stop at 1 min when alarm is triggered;<br />

however, the SR/BX’s LED keeps flashing<br />

until 3 mins is expired).<br />

and no siren/warning sound will be made at all<br />

times.<br />

• To disable the internal siren, u<strong>se</strong> command<br />

24 with option 0. Usage as below:<br />

240<br />

• To enable the internal siren, u<strong>se</strong> command<br />

24 with option 1. Usage as below:<br />

241<br />

Enable is <strong>se</strong>t as factory default.<br />

<br />

If <strong>se</strong>t as Disable, when <strong>UniAlert</strong><br />

receives an alarm/status/fault signal,<br />

no sound will be made from the<br />

internal siren. However, external<br />

sirens (SR & BX) and Alarm Output<br />

are not affected and will continue to<br />

perform as programmed.<br />

2.8. Internal Siren<br />

The <strong>UniAlert</strong>’s internal siren can be disabled,<br />

9<br />

2.8. Add/Remove Device<br />

A total of 20 devices can be leant into the


system. Each device occupies a zone number.<br />

2.8.1. Add Devices<br />

Step 1. To learn in a device, u<strong>se</strong> command 91<br />

then followed by a zone number.<br />

Usage as below:<br />

Where:<br />

01 = Zone 1<br />

20 = Zone 20<br />

<br />

9101<br />

9120<br />

If the zone is already in u<strong>se</strong>, the<br />

<strong>UniAlert</strong> will emit a 2-tone sound to<br />

indicate.<br />

Step 2. The <strong>UniAlert</strong> is now in Learn mode.<br />

Press the test/learn button on the<br />

device or any button on the Remote<br />

Controller.<br />

Step 3. If a signal is received, the <strong>UniAlert</strong> will<br />

beep twice to confirm then exit Learn<br />

mode automatically.<br />

<br />

If a device has been previously learnt<br />

into other zone, the <strong>UniAlert</strong> will beep<br />

once to indicate and stays in Learn<br />

mode for you to re-enter the command<br />

with an available zone number.<br />

Time-out for Learn mode is 10<br />

<strong>se</strong>conds, or 5 <strong>se</strong>conds for incomplete<br />

command entered (e.g. entered “ 91”<br />

only, with no sub<strong>se</strong>quent zone #).<br />

When exiting Learn mode, 4 beeps<br />

will be heard to indicate.<br />

<br />

<br />

<br />

Carbon Monoxide --- CO<br />

Water Sensor --- WS<br />

Wrist/Pendant Transmitter ---<br />

WTR<br />

For Door Contact (DC), the attribute<br />

is <strong>se</strong>t fixed to Entry.<br />

<br />

<br />

<br />

When the system is in Away<br />

arm mode, if an Entry Door<br />

Contact is triggered, the<br />

<strong>UniAlert</strong> will start an entry period<br />

to give enough time to disarm<br />

the system.<br />

After the delay period is expired<br />

and no correct PIN code is<br />

entered to disarm the system,<br />

the <strong>UniAlert</strong> will respond with a<br />

Burglar Alarm and an event<br />

code 130 will be reported.<br />

When the system is in Alarm off<br />

mode, if an Entry Door Contact<br />

is triggered, the Control Panel<br />

will make a ding-dong sound for<br />

Door Chime.<br />

For PIR (IR) and External PIR (EIR),<br />

the attribute is <strong>se</strong>t fixed to Burglar.<br />

<br />

When the system is in Away<br />

arm mode, if a Burglar IR/EIR<br />

is triggered, the <strong>UniAlert</strong> will<br />

respond with a Burglar Alarm<br />

and an event code 130 will be<br />

reported.<br />

The categories of devices are listed as<br />

followings:<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Remote Controller --- RC<br />

Remote Keypad --- KP<br />

Panic Button --- PB<br />

Night Switch --- NS<br />

Door Contact --- DC<br />

PIR Sensor --- IR<br />

External PIR --- EIR<br />

<br />

Smoke Detector --- SD<br />

10<br />

2.8.2. Remove Devices<br />

Adding a device for a <strong>se</strong>cond time is prohibited


unless it is removed from the system first.<br />

• To remove all devices at once, u<strong>se</strong><br />

command 80 as below:<br />

8099<br />

• To remove a particular device, u<strong>se</strong><br />

command 81 followed by the zone number.<br />

Usage as below:<br />

Where:<br />

01 = Zone 1<br />

20 = Zone 20<br />

<br />

8001<br />

8020<br />

If the zone number does not exist (no<br />

device learnt), the <strong>UniAlert</strong> will emit a<br />

4 beeps to indicate.<br />

When the device(s) is/are successfully<br />

removed, the <strong>UniAlert</strong> will beep twice to<br />

confirm.<br />

2.9. Program Siren<br />

<br />

For outdoor Bell Box BX-8 and/or<br />

indoor Siren SR-8, at least one device<br />

must be learnt in first in order to<br />

program siren.<br />

If an outdoor Bell Box (BX) or indoor Siren (SR)<br />

is to be included in the system, it should be<br />

programmed first by the <strong>UniAlert</strong>, so that the<br />

<strong>UniAlert</strong> can communicate with the<strong>se</strong> auxiliary<br />

devices.<br />

Learn Bell Box (BX) / Siren (SR)<br />

Step 1. Put the desired auxiliary device into<br />

learn mode (plea<strong>se</strong> refer to its<br />

individual Operation Manual). U<strong>se</strong><br />

command 92 with option 1. Usage as<br />

below:<br />

921<br />

to all devices simultaneously. The<br />

BX/SR should respond by activating<br />

its siren and/or strobe light<br />

momentarily, and the <strong>UniAlert</strong> will also<br />

beep twice to confirm.<br />

Step 3. Place the<strong>se</strong> auxiliary devices out of<br />

learn mode. Adding them into the<br />

system is now complete.<br />

<br />

If any of the<strong>se</strong> devices does not<br />

respond, make sure that the device is<br />

in learn mode and re-enter the<br />

command.<br />

<br />

For the following <strong>se</strong>ttings/commands,<br />

whichever option is <strong>se</strong>lected, when the<br />

<strong>UniAlert</strong> transmits the signal, all added<br />

sirens will simultaneously receive the<br />

signal and will all act accordingly.<br />

Siren Tamper On, Siren Tamper Off<br />

The BX/SR tamper switch can be enabled and<br />

disabled remotely. This is u<strong>se</strong>d especially<br />

when replacing BX/SR battery.<br />

• To disable the BX/SR tamper switch, u<strong>se</strong><br />

command 92 with option 3. Usage as<br />

below:<br />

923<br />

All added BX/SR will temporarity lo<strong>se</strong> their<br />

tamper protection simultanously.<br />

• To enable the BX/SR tamper switch, u<strong>se</strong><br />

command 92 with option 2. Usage as<br />

below:<br />

922<br />

All added BX/SR will be enable their<br />

tamper protection simultanously.<br />

When the command is accepted, the <strong>UniAlert</strong><br />

will beep twice to confirm. The BX/SR will also<br />

emit a beep to confirm. If no sound is heard<br />

from BX/SR within 10 <strong>se</strong>c, that means no<br />

signal is received. Plea<strong>se</strong> re<strong>se</strong>nd the command.<br />

Step 2. The <strong>UniAlert</strong> will transmit learning code<br />

<br />

The Siren tamper disable will<br />

11


automatically revert to On after about<br />

an hour if not switched back.<br />

Confirm On, Confirm Off<br />

The BX/SR can be enabled for arming and<br />

disarming confirmation, that beeps are emitted<br />

from the siren to validate that the system has<br />

been armed and disarmed.<br />

• To disable the BX/SR siren confirmation,<br />

u<strong>se</strong> command 92 with option 5. Usage as<br />

below:<br />

925<br />

• To enable the BX/SR siren confirmation,<br />

u<strong>se</strong> command 92 with option 4. Usage as<br />

below:<br />

924<br />

When the command is accepted, the <strong>UniAlert</strong><br />

will beep twice to confirm. The <strong>UniAlert</strong> will<br />

beep twice to confirm. The BX/SR will also emit<br />

a beep to confirm. If no sound is heard from<br />

BX/SR within 10 <strong>se</strong>c, that means no signal is<br />

received. Plea<strong>se</strong> re<strong>se</strong>nd the command.<br />

siren/warning sound will be made at all times.<br />

• To disable the BX/SR, u<strong>se</strong> command 92<br />

with option 0. Usage as below:<br />

920<br />

• To enable the BX/SR again, u<strong>se</strong> command<br />

92 with option 1. Usage as below:<br />

921<br />

When the command is accepted, the <strong>UniAlert</strong><br />

will beep twice to confirm.<br />

Entry/Exit Sound On, Entry/Exit Sound Off<br />

The BX/SR can be enabled or disabled to<br />

sound the Entry/Exit delay warning beeps.<br />

• To disable the BX/SR entry/exit sound, u<strong>se</strong><br />

command 92 with option 7. Usage as<br />

below:<br />

927<br />

• To enable the BX/SR entry/exit sound, u<strong>se</strong><br />

command 92 with option 6. Usage as<br />

below:<br />

926<br />

When the command is accepted, the <strong>UniAlert</strong><br />

will beep twice to confirm. The <strong>UniAlert</strong> will<br />

beep twice to confirm. The BX/SR will also emit<br />

a beep to confirm. If no sound is heard from<br />

BX/SR within 10 <strong>se</strong>c, that means no signal is<br />

received. Plea<strong>se</strong> re<strong>se</strong>nd the command.<br />

Disable Bell Box (BX) / Siren (SR)<br />

All BX/SR can be disabled and no<br />

12<br />

2.10. Remote Programming<br />

via SMS Commands


The <strong>UniAlert</strong> can also be programmed<br />

remotely via SMS commands. All programming<br />

options require SMS commands to be <strong>se</strong>nt in<br />

specific formats. All commands require a SMS<br />

Program Word (SMS P-Word, default PROG,<br />

and a SMS Keyword (default SET). Plea<strong>se</strong><br />

refer to <strong>se</strong>ction 3.8 Programmig Command<br />

Table for more details.<br />

All below instructions/examples are ba<strong>se</strong>d on<br />

factory default. U<strong>se</strong>r is to substitute own P-<br />

Word and Keyword if changed.<br />

2.10.1. SMS Program Word (P-Word)<br />

The default SMS P-Word can be changed to<br />

own word by using command 1A. A maximum<br />

of 15 characters is allowed. Usage as below:<br />

1AJACK<br />

PROG is <strong>se</strong>t as factory default.<br />

Once this SMS command is received by<br />

<strong>UniAlert</strong>, the previous P-Word, PROG, is<br />

replaced by JACK.<br />

2.10.2. SMS Keyword<br />

To <strong>se</strong>nd remote commands to system via SMS<br />

message, a personalized password is required<br />

for <strong>UniAlert</strong> to recognize your authority.<br />

The default SMS Keyword can be changed to<br />

own word by using command 1B. A maximum<br />

of 10 characters is allowed. Usage as below:<br />

1BKEY<br />

SET is <strong>se</strong>t as factory default.<br />

Once this SMS command is received by<br />

<strong>UniAlert</strong>, the previous SMS Keyword, SET, is<br />

replaced by KEY.<br />

The text you entered in SMS Header will<br />

display be displayed in each SMS alarm<br />

message reported to your mobile phone.<br />

For example, if you enter your address in SMS<br />

Header, your address will be shown in SMS<br />

alarm messages; the format is (your address,<br />

Panic Alarm)<br />

For <strong>se</strong>nding a SMS alarm reporting to your<br />

mobile phone, enter your SMS Header by<br />

using command 1C. A maximum of 64<br />

characters is allowed. Usage as below:<br />

1CADDRESS<br />

ALARM UNIALERT is <strong>se</strong>t as factory default.<br />

Once this SMS command is received by<br />

<strong>UniAlert</strong>, the previous SMS Header, ALARM<br />

UNIALERT, is replaced by ADDRESS.<br />

<br />

The saved SMS Header will be <strong>se</strong>nt<br />

along with the SMS status message to<br />

mobile phone.<br />

If no SMS Header is programmed,<br />

only the SMS alarm message will be<br />

<strong>se</strong>nt to mobile phone.<br />

2.11. Walk Test (Local<br />

Programming Only)<br />

• U<strong>se</strong> command 93 to start Walk Test.<br />

Usage as below:<br />

93<br />

When the command is accepted, the<br />

<strong>UniAlert</strong> will beep twice to confirm.<br />

• By pressing the test button on the device,<br />

Remote Controller, or triggering the <strong>se</strong>nsor,<br />

if the <strong>UniAlert</strong> receives the signal, it will<br />

emit a 2-tone ding-dong sound to confirm.<br />

• Once the device testing is satisfactory,<br />

press Disarm key once to end Walk Test.<br />

2.10.3. SMS Header<br />

13


2.12. Exiting Programming<br />

Mode<br />

Once programming is completed, u<strong>se</strong><br />

command 99 to exit programming mode.<br />

Usage as below:<br />

99<br />

When the command is accepted, the <strong>UniAlert</strong><br />

will beep twice to confirm.<br />

<br />

In Programming mode, if no key is<br />

pres<strong>se</strong>d or no RF signal is received<br />

within 3 minutes, the <strong>UniAlert</strong> will emit<br />

5 beeps and automatically exit<br />

Programming mode to Disarm mode.<br />

14<br />

3. Operation


3.1. Away (Alarm On) Mode<br />

When the system is in Disarm (Alarm Off)<br />

mode, and arming the system is wished,<br />

plea<strong>se</strong> follow the steps below:<br />

Step 1. Enter a U<strong>se</strong>r PIN code (U<strong>se</strong>r 1 PIN<br />

code 1234 is <strong>se</strong>t as factory default).<br />

Step 2. Press the<br />

Arm key.<br />

Step 3. The defined EXIT Delay is counting<br />

down. During the EXIT Delay period,<br />

the exit sound plays, unless it has<br />

been cho<strong>se</strong>n to switch off.<br />

<br />

During the Exit Delay Count Down<br />

Period:<br />

• Exit Delay Sound:<br />

If it is <strong>se</strong>t as 01-70 <strong>se</strong>c, there will be<br />

a beep at every <strong>se</strong>cond, until the<br />

Count Down timer expires.<br />

If it is <strong>se</strong>t as 00 (Disable), a silent<br />

count down will be performed.<br />

• Latch Report Option:<br />

If it is <strong>se</strong>t as ON, an Arming report<br />

will be <strong>se</strong>nt to Central Monitoring<br />

Station.<br />

If it is <strong>se</strong>t as OFF, no report will be<br />

<strong>se</strong>nt.<br />

Step 4. When Exit Delay timer expires, the<br />

<strong>UniAlert</strong> will perform a long beep and<br />

the system is now in Arm Mode.<br />

<br />

The system can also be armed by<br />

pressing the Arm button on the<br />

Remote Controller.<br />

Exit Timer is ineffective if the<br />

Home/Partial Arm Button of the<br />

Remote Controller (RC) is pres<strong>se</strong>d.<br />

That is, the <strong>UniAlert</strong> enters Arm mode<br />

immediately when the Home/Partial<br />

Arm Button of the RC is pres<strong>se</strong>d.<br />

The Exit Delay can be stopped by disarming<br />

the system.<br />

Step 1. Key in your U<strong>se</strong>r PIN code, followed<br />

by Disarm key.<br />

Step 2. If the U<strong>se</strong>r PIN code is correct, then<br />

the exit sound will be stopped.<br />

<br />

The Exit Delay can also be stopped by<br />

pressing the Disarm button on the<br />

Remote Controller.<br />

If the Exit Delay period times out<br />

before the code can be entered, the<br />

system will be armed.<br />

3.1.2. Extend the Exit Delay<br />

During the Exit Delay period, the delay time<br />

can be extended. Each time the delay time is<br />

extended, the timer tarts counting from the<br />

beginning.<br />

Step 1. Key in your U<strong>se</strong>r PIN code, followed<br />

by Arm key.<br />

Step 2. If the U<strong>se</strong>r PIN code is correct, you<br />

will continue to hear the exit sound.<br />

<br />

The Exit Delay can also be extended<br />

by pressing the Arm button on the<br />

Remote Controller.<br />

While you arm the system, if the<br />

<strong>UniAlert</strong> is triggered (e.g. motion<br />

detected), arming is also prohibited.<br />

3.2. Disarm (Alarm Off) Mode<br />

When the system is in Arm mode, enter the<br />

U<strong>se</strong>r PIN Code and press Disarm key. If the<br />

PIN code is correct, the systeml will emit 2<br />

short beeps and return to Disarm mode.<br />

<br />

When the system is Armed, pressing<br />

the Disarm button on the Remote<br />

Controller can also disarm the system.<br />

3.1.1. Stopping the Exit Delay<br />

15<br />

3.3. Stop the Alarm<br />

During any alarm, the <strong>UniAlert</strong> wil sound its<br />

siren and report to the Phone number


programmed previously.<br />

During an alarm, to stop the siren:<br />

Step 1. Key in your U<strong>se</strong>r PIN code, followed<br />

by Disarm key.<br />

Step 2. If the U<strong>se</strong>r PIN code is correct, then<br />

the alarm sound will be stopped.<br />

<br />

When an alarm is rai<strong>se</strong>d, press the<br />

Disarm button on the Remote<br />

Controller will also stop the alarm.<br />

3.4. Dual-Key Function<br />

You may manually trigger Panic, Fire, and<br />

Emergency alarms if needed.<br />

• Panic Alarm — Press & Hold 1 key + 3<br />

key at the same time for 3 <strong>se</strong>conds.<br />

• Fire Alarm — Press & Hold 4 key + 6 key<br />

at the same time for 3 <strong>se</strong>conds.<br />

• Emergency Alarm — Press & Hold 7 key +<br />

9 key at the same time for 3 <strong>se</strong>conds.<br />

To stop the<strong>se</strong> alarms, simply follow the normal<br />

disarm procedure.<br />

3.5. Faulty Situations<br />

• The <strong>UniAlert</strong> is capable of detecting<br />

following fault events:<br />

<br />

<br />

<br />

<br />

AC Power Fail<br />

<strong>UniAlert</strong>/Device Low Battery<br />

<strong>UniAlert</strong>/Device Tamper<br />

<strong>GSM</strong> not ready<br />

• In ca<strong>se</strong> any fault condition is detected, the<br />

<strong>UniAlert</strong> will respond with a Fault alarm<br />

respectively according to the nature of the<br />

faulty event.<br />

• Device sabotaged<br />

• The <strong>UniAlert</strong> and Remote Keypad<br />

are Tamper protected.<br />

<br />

<strong>UniAlert</strong><br />

A Tamper switch protects <strong>UniAlert</strong><br />

from any removal attempts away<br />

from its wall mounting bracket.<br />

• Device low battery<br />

If the battery voltage of Remote Keypad,<br />

or Remote Controller is low, a Device Low<br />

Battery message will be reported.<br />

• <strong>GSM</strong> not ready<br />

If the SIM card is found missing,<br />

improperly in<strong>se</strong>rted, PUK/PIN code<br />

locked, no <strong>GSM</strong> reception, or faulty, the<br />

Green LED will flash to indicate.<br />

3.5.1. Fault Event Respon<strong>se</strong><br />

• In all modes, the <strong>UniAlert</strong> and the external<br />

sirens will NOT sound audible siren for<br />

fault event (except Sabotaged/Tamper<br />

alarm).<br />

• In all modes, when AC power<br />

failure/restore, Device low battery/restore,<br />

or <strong>UniAlert</strong>/Device Tamper open/restore,<br />

the <strong>UniAlert</strong> will <strong>se</strong>nd fault report by SMS<br />

(both SMS Text message to u<strong>se</strong>r and<br />

SCID to the Central Monitoring Station).<br />

Once the fault is restored, the <strong>UniAlert</strong> will<br />

also report the restore event by SMS to<br />

the telephone numbers.<br />

• AC Power Fail<br />

The Green LED will flash slowly<br />

(60ms On / 2.5s Off) and an AC<br />

Fault Report will be <strong>se</strong>nt after 30<br />

<strong>se</strong>c.<br />

When AC is restored for more than<br />

30 <strong>se</strong>c, an AC Restore Report will<br />

be <strong>se</strong>nt and the Green LED will<br />

stop flashing.<br />

• <strong>UniAlert</strong> Low Battery<br />

When the <strong>UniAlert</strong> low battery is<br />

detected, Green LED will flash<br />

slowly (60ms On / 2.5s Off) and a<br />

Low Battery Report will be <strong>se</strong>nt<br />

after 30 <strong>se</strong>c.<br />

When Low Battery is restored for<br />

more than 30 <strong>se</strong>c, a Low Battery<br />

Restore Report will be <strong>se</strong>nt and the<br />

Green LED will stop flashing.<br />

• Sensor Low Battery<br />

When low battery is detected on<br />

any <strong>se</strong>nsor, Green LED will flash<br />

quickly (60ms On / 500ms Off) and<br />

a Device Low Battery Report will be<br />

<strong>se</strong>nt immediately.<br />

When Low Battery is restored for<br />

more than 30 <strong>se</strong>c, a Low Battery<br />

16


Restore Report will be <strong>se</strong>nt and the<br />

Green LED will stop flashing.<br />

• Panel Sabotaged<br />

If the Tamper switch on the <strong>UniAlert</strong><br />

is triggered, Green LED will flash<br />

(ON 60 ms / OFF 2.5s).<br />

• Sensor Sabotaged<br />

If the Tamper switch on any <strong>se</strong>nsor,<br />

Remote Keypad, or Bell Box is<br />

triggered, Green LED will flash (ON<br />

60ms / OFF 500ms).<br />

The format of SMS CID message is:<br />

Where<br />

ACCT MT QXYZ GG CCC<br />

ACCT = 4 Digit Account number (0-9)<br />

MT = Message Type, 18H.<br />

Q<br />

= Event qualifier, which gives<br />

specific event information:<br />

XYZ = Event code (3 Hex digits 0-9)<br />

GG<br />

= Group or Partition number (00H)<br />

3.6. Remote Commanding<br />

(SMS Only)<br />

The <strong>UniAlert</strong> can be controlled by Remote<br />

Control Commands <strong>se</strong>nt via SMS messages.<br />

Plea<strong>se</strong> be reminded to change the language<br />

<strong>se</strong>tting of your mobile phone to English<br />

prior to proceed.<br />

• SMS Remote Control Command Table<br />

Control<br />

Command<br />

Result<br />

CCC<br />

= Zone Number<br />

000 UNIALERT<br />

001 Zone 1<br />

002 Zone 2<br />

003 Zone 3<br />

……………<br />

……………<br />

018 Zone 18<br />

019 Zone 19<br />

020 Zone 20<br />

021<br />

41<br />

(option 1)<br />

41<br />

(option 0)<br />

Arm<br />

Disarm<br />

All below instructions/examples are ba<strong>se</strong>d on<br />

factory default. U<strong>se</strong>r is to substitute own SMS<br />

Keywor and U<strong>se</strong>r PIN code if changed.<br />

• To <strong>se</strong>nd SMS message to command the<br />

<strong>UniAlert</strong> to enter Arm/Disarm Mode, the<br />

usage is:<br />

Where:<br />

SET = SMS Keyword<br />

“_” = Space<br />

1234 = U<strong>se</strong>r PIN code<br />

41 = Arm mode<br />

1 = Option 1, Arm<br />

0 = Option 0, Disarm<br />

SET_1234_*41_1*<br />

SET_1234_*41_0*<br />

3.7. Message Composition<br />

17


3.8. Programming Command Table<br />

Programming commands, usages, and defaults are summarized as below:<br />

COMMAND USAGE ACK DEFAULT<br />

10<br />

11<br />

12<br />

13<br />

Set Master PIN code (4 digits, 0000-9999)<br />

(The code cannot be deleted.)<br />

Set U<strong>se</strong>r 1 PIN code (4 digits, 0000-9999)<br />

Latch Report Off (4 digits, 0000-9999) + 0<br />

Latch Report On (4 digits, 0000-9999) + 1<br />

(The code cannot be deleted.)<br />

Set U<strong>se</strong>r 2 PIN code (4 digits, 0000-9999)<br />

Latch Report Off (4 digits, 0000-9999) + 0<br />

Latch Report On (4 digits, 0000-9999) + 1<br />

Delete the code (no digit)<br />

Set U<strong>se</strong>r 3 PIN code (4 digits, 0000-9999)<br />

Latch Report Off (4 digits, 0000-9999) + 0<br />

Latch Report On (4 digits, 0000-9999) + 1<br />

Delete the code (no digit)<br />

bi-bi 1111<br />

bi-bi<br />

1234<br />

(0: Latch Report Off)<br />

bi-bi ---<br />

bi-bi ---<br />

14<br />

Set U<strong>se</strong>r 4 PIN code (4 digits, 0000-9999)<br />

Latch Report Off (4 digits, 0000-9999) + 0<br />

Latch Report On (4 digits, 0000-9999) + 1<br />

bi-bi ---<br />

Delete the code (no digit)<br />

1A Set SMS P-Word (15 characters) PROG<br />

1B Set SMS Keyword (10 characters) SET<br />

1C Set SMS Header (64 characters) ALARM <strong>UniAlert</strong> <strong>GSM</strong><br />

21 Set Alarm Length (2 digits, 00-15, unit: minute) bi-bi 3 minutes<br />

22 Set Entry Time (2 digits, 00-70, unit: <strong>se</strong>cond) bi-bi 30 <strong>se</strong>conds<br />

23 Set Exit Time (2 digits, 00-70, unit: <strong>se</strong>cond) bi-bi 30 <strong>se</strong>conds<br />

24<br />

Set internal siren On/Off<br />

0: Disable internal siren<br />

1: Enable internal siren<br />

bi-bi<br />

1<br />

(On)<br />

31<br />

Set SMS Telephone number 1<br />

Set Text: 0 + TEL (20 digits)<br />

Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20digits)<br />

Delete the number (no digit)<br />

bi-bi<br />

No number<br />

32<br />

Set SMS Telephone number 2<br />

Set Text: 0 + TEL (20 digits)<br />

Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20 digits)<br />

Delete the number (no digit)<br />

bi-bi<br />

No number<br />

33<br />

Set SMS Telephone number 3<br />

Set Text: 0 + TEL (20 digits)<br />

Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20 digits)<br />

Delete the number (no digit)<br />

bi-bi<br />

No number<br />

34<br />

Set SMS Telephone number 4<br />

Set Text: 0 + TEL (20 digits)<br />

Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20 digits)<br />

Delete the number (no digit)<br />

bi-bi<br />

No number<br />

39<br />

SCID reach:<br />

0: one of the TEL 1-4 (if <strong>se</strong>t as SCID)<br />

1: all the TEL 1-4 (if <strong>se</strong>t as SCID)<br />

bi-bi<br />

1<br />

(all)<br />

41<br />

Set Arm mode (Remote control via SMS)<br />

1: Arm<br />

0: Disarm<br />

80<br />

81<br />

Remove all device<br />

99<br />

Remove a particular device:<br />

Zone number (2 digits, 01-20)<br />

If the zone does not exist, ---> do-di<br />

bi-bi ---<br />

bi-bi ---<br />

18


COMMAND USAGE ACK DEFAULT<br />

91<br />

Learn-in device:<br />

Zone number (2 digits, 01-20) + press “Disarm” then 10 <strong>se</strong>c time out,<br />

otherwi<strong>se</strong> 5 <strong>se</strong>c time out for incomplete command, time out bi-bi-bi-bi<br />

If successfully learnt, ---> bi-bi and exit learn mode<br />

If zone number is in u<strong>se</strong>, ---> do-di<br />

If the device is already learnt in other zone, ---> bi and continue to stay in learn mode<br />

bi-bi<br />

No device<br />

92<br />

93<br />

97<br />

98<br />

Program Siren:<br />

0: Disable BX/SR<br />

1: Learn Siren<br />

2: Siren Tamper On<br />

3: Siren Tamper Off<br />

4: Confirm On<br />

5: Confirm Off<br />

6: Entry/Exit Sound On<br />

7: Entry/Exit Sound Off<br />

Walk Test: signal received --> ding-dong<br />

(press “Disarm” to end Walk Test)<br />

0: Re<strong>se</strong>t Master Code to factory default 1111<br />

1: Re<strong>se</strong>t U<strong>se</strong>r 1 PIN code to factory default 1234, and<br />

U<strong>se</strong>rs PIN 2-4 deactivated<br />

2: Re<strong>se</strong>t SMS P-Word/SMS Keyword, and SMS Header to factory default<br />

Re<strong>se</strong>t all to factory default<br />

2580<br />

bi-bi<br />

bi-bi<br />

Disable<br />

bi-bi ---<br />

bi-bi ---<br />

99 Exit programming mode bi-bi ---<br />

<br />

In Programming mode, press<br />

Arm key at anytime to abort <strong>se</strong>ttting.<br />

Commands 1A to 1C,41 are for SMS only, and Commands 80 to 99 are for Keypad only.<br />

All other Commands can be u<strong>se</strong>d by both SMS & Keypads.<br />

<br />

Examples of remote SMS commanding is as shown below:<br />

• To remote Arm/Disarm:<br />

If SMS Keyword is “SET”, and U<strong>se</strong>r code is “1234”:<br />

To Arm : SET_1234_*41_1*<br />

To Disarm: SET_1234_*41_0*<br />

• To remote program:<br />

If SMS P-Word is “PROG”, and Master Code is “1111”:<br />

To <strong>se</strong>t TEL-1 for SMS (Text): PROG_1111_*31_0_0911907086*<br />

To <strong>se</strong>t TEL-2 for SMS (SCID): PROG_1111_*32_4_5678_0911907086*<br />

where “_” is a space<br />

19


4. Appendix<br />

4.1. Re<strong>se</strong>t Procedure<br />

Re<strong>se</strong>t All to Factory Default<br />

Setting<br />

• When the system is off, and Tamper is<br />

protruding (open):<br />

Step 1. Press and hold the 3 key while<br />

powering up. Relea<strong>se</strong> the button when<br />

a long beep is heard.<br />

Step 2. Enter 258009. A ding-dong sound will<br />

be heard to confirm all <strong>se</strong>ttings are<br />

restored to factory default.<br />

Step 3. 2 short beeps will then be heard to<br />

indicate the system is now in Disarm<br />

mode:<br />

• When the system on and is in Disarm<br />

mode:<br />

Step 1. Enter Programming mode by keying in<br />

the Master Code then press the<br />

Disarm key twice.<br />

<br />

The <strong>se</strong>cond Disarm key must be<br />

pres<strong>se</strong>d within 0.5 <strong>se</strong>cond.<br />

Step 2. When successfully entered<br />

Programming mode, the Green & Red<br />

LED will flash alternately.<br />

Step 3. Enter the command by pressing<br />

“ 982580 ”.<br />

Step 4. Exit Programming mode by pressing<br />

“ 99 ”.<br />

<br />

For all programming commands<br />

entered, 2 beeps will be heard to<br />

confirm the command is accepted and<br />

executed. On the other hand, 4 beeps<br />

will be heard to indicate the command<br />

is errounous or unacceptable.<br />

Once the Factory Re<strong>se</strong>t is executed,<br />

all the programmed data are returned<br />

to its default value and all the devices<br />

having been learnt-in are removed.<br />

You have to do the programming and<br />

learn in the device one by one again.<br />

Re<strong>se</strong>t Only Master Code<br />

Repeat the above procedure except step 3:<br />

Step 3. Enter command 97 with option 0, by<br />

pressing “ 970 ”.<br />

<br />

Once this command is executed, the<br />

Master Code is re<strong>se</strong>t to 1111.<br />

Re<strong>se</strong>t Only U<strong>se</strong>r PIN Codes<br />

Repeat the above procedure except step 3:<br />

Step 3. Enter command 97 with option 1, by<br />

pressing “ 971 ”.<br />

<br />

Once this command is executed, U<strong>se</strong>r<br />

1 PIN code is re<strong>se</strong>t to 1234. U<strong>se</strong>r 2 to<br />

4 PIN codes are deactivated.<br />

Re<strong>se</strong>t Only SMS P-Word, SMS<br />

Keyword, and SMS Header<br />

Repeat the above procedure except step 3:<br />

Step 3. Enter command 97 with option 2, by<br />

pressing “ 972 ”.<br />

<br />

Once this command is executed, SMS<br />

P-Word is re<strong>se</strong>t to PROG, SMS<br />

Keyword is re<strong>se</strong>t to SET, and SMS<br />

Header is re<strong>se</strong>t to ALARM<br />

UNIALERT.<br />

20


4.2. Event Code<br />

• 101 - Emergency<br />

Dual-Key 7+9<br />

• 110 - Fire<br />

Dual-Key 4+6<br />

SD<br />

• 120 - Panic<br />

When the of the Remote Controller is<br />

pres<strong>se</strong>d.<br />

Dual-Key 1 +3<br />

PB / WTR<br />

• 130 - Burglary<br />

When any one of the following devices<br />

is triggered:<br />

‣ The <strong>UniAlert</strong><br />

‣ Wired Terminal<br />

‣ IR / DC(Entry) / EIR<br />

• 137 - Burglary Tamper<br />

When the Tamper Switch on the Min<br />

<strong>GSM</strong> l is triggered.<br />

• 154 - Water Leakage<br />

When the Water Sensor connected to<br />

DC <strong>se</strong>t at Water (@W) is triggered.<br />

• 162 - CO Detector<br />

When the Carbon Monoxide detector<br />

is triggered.<br />

• 301 - AC Failure<br />

When the AC power fails for more<br />

than 30 <strong>se</strong>c.<br />

• 302 - Low battery<br />

When the battery voltage of the<br />

<strong>UniAlert</strong> is low.<br />

• 383 - Sensor Tamper<br />

When the Tamper Switch on any one<br />

of the following devices is triggered .<br />

‣ KP<br />

‣ PIR/EIR<br />

‣ DC<br />

• 384 - Sensor Low battery<br />

When the battery voltage of any one<br />

of the following devices is low.<br />

‣ RC/WTR/NS/PB<br />

‣ KP<br />

‣ DC<br />

‣ PIR/EIR<br />

‣ SD/CO<br />

‣ WS<br />

‣ BX/SR<br />

• 401 - Latch On<br />

When <strong>UniAlert</strong> Pin Code Latch is <strong>se</strong>t<br />

as On, and when enters Arm mode,<br />

event code 3401 will be <strong>se</strong>nt.<br />

• 406 - Panel Alarm Cancel<br />

• 407- Remote Arm/Disarm<br />

• 465 - Device Alarm Cancel (SD/PB/WTR)<br />

<br />

<br />

When the alarm from Panic Button<br />

(PB) or Wrist Transmitter (WTR) is<br />

cancelled within 8 <strong>se</strong>conds<br />

When an alarm is triggered by SD<br />

and the test button on the SD is<br />

pres<strong>se</strong>d<br />

21


DECLARATION OF<br />

CONFORMITY<br />

Hereby <strong>Electia</strong> AB declares that the <strong>UniAlert</strong><br />

<strong>GSM</strong> is in compliance with the es<strong>se</strong>ntial<br />

requirements and other relevant provisions of<br />

directive 1999/5/EC and RoHs 2002/95/EC.<br />

Härmed intygar <strong>Electia</strong> AB att <strong>UniAlert</strong> <strong>GSM</strong><br />

står i överensstämmel<strong>se</strong> med de vä<strong>se</strong>ntliga<br />

egenskapskrav och övriga relevanta<br />

bestämmel<strong>se</strong>r som framgår av direktiv<br />

1999/5/EG och RoHs 2002/95/EG.<br />

Peder Ljungstedt<br />

Produktansvarig<br />

<strong>Electia</strong> AB<br />

CE 0678<br />

At the end of its life, tho<strong>se</strong> products should<br />

NOT be dispo<strong>se</strong>d of in hou<strong>se</strong>hold rubbish.<br />

Seek the advice of your local authority on<br />

correct, environmentally friendly disposal.<br />

Batteries<br />

Do not dispo<strong>se</strong> of u<strong>se</strong>d batteries in the<br />

hou<strong>se</strong>hold rubbish! They should be deposited<br />

at a collection point for u<strong>se</strong>d batteries.<br />