<strong>UniAlert</strong> <strong>GSM</strong>
Table of Contents<br />
1. Application Overview________________________________________________________ 1<br />
1.1. Identifying the Parts _______________________________________________________________ 1<br />
1.2. In<strong>se</strong>rt <strong>GSM</strong> SIM Card _____________________________________________________________ 2<br />
1.3. The Power Supply ________________________________________________________________ 3<br />
1.4. Input/Output & DC Terminals ______________________________________________________ 3<br />
1.5. How to install the <strong>UniAlert</strong> _________________________________________________________ 4<br />
1.6. Two-Level Passwords ______________________________________________________________ 4<br />
1.7. Getting Started ___________________________________________________________________ 4<br />
2. Configuring Your System ____________________________________________________ 5<br />
2.1. Entering Programming Mode _______________________________________________________ 6<br />
2.2. Telephone Settings ________________________________________________________________ 6<br />
2.3. PIN Code ________________________________________________________________________ 7<br />
2.4. Master Code _____________________________________________________________________ 7<br />
2.5. Entry Time ______________________________________________________________________ 8<br />
2.6. Exit Time ________________________________________________________________________ 8<br />
2.7. Alarm Length ____________________________________________________________________ 8<br />
2.8. Internal Siren ____________________________________________________________________ 9<br />
2.8. Add/Remove Device _______________________________________________________________ 9<br />
2.8.1. Add Devices _______________________________________________________________________ 10<br />
2.8.2. Remove Devices ___________________________________________________________________ 10<br />
2.9. Program Siren __________________________________________________________________ 11<br />
2.10. Remote Programming via SMS Commands _________________________________________ 12<br />
2.10.1. SMS Program Word (P-Word)_______________________________________________________ 13<br />
2.10.2. SMS Keyword _____________________________________________________________________ 13<br />
2.10.3. SMS Header_______________________________________________________________________ 13<br />
2.11. Walk Test (Local Programming Only) ______________________________________________ 13<br />
2.12. Exiting Programming Mode ______________________________________________________ 14<br />
3. Operation _________________________________________________________________ 14<br />
3.1. Away (Alarm On) Mode __________________________________________________________ 15<br />
3.2. Disarm (Alarm Off) Mode _________________________________________________________ 15<br />
3.3. Stop the Alarm __________________________________________________________________ 15<br />
3.4. Dual-Key Function _______________________________________________________________ 16<br />
1
3.5. Faulty Situations _________________________________________________________________ 16<br />
3.6. Remote Commanding (SMS Only) __________________________________________________ 17<br />
3.7. Message Composition _____________________________________________________________ 17<br />
3.8. Programming Command Table ____________________________________________________ 18<br />
4. Appendix __________________________________________________________________ 20<br />
4.1. Re<strong>se</strong>t Procedure _______________________________________________________________ 20<br />
4.2. Event Code ____________________________________________________________________ 21<br />
2
1. Application Overview<br />
1.1. Identifying the Parts<br />
— FLASH SYNCHRONOUSLY WITH<br />
GREEN LED: Walk Test<br />
— QUICK FLASH FOR 1.6 SEC: PIR<br />
trigger<br />
4<br />
Numeric Keys<br />
1<br />
2<br />
Internal PIR Detector<br />
Green LED<br />
— ON: Power On<br />
— FLASH (1s On / 1s Off): <strong>GSM</strong> fault<br />
— SLOW FLASH (60ms On / 2.5s Off):<br />
<strong>UniAlert</strong> Tamper fault or Low Battery<br />
or AC fault<br />
— QUICK FLASH (60ms On / 500ms<br />
Off): Device Tamper fault or Low<br />
Battery<br />
— FLASH ALTERNATELY WITH RED<br />
LED: Programming mode<br />
— FLASH SYNCHRONOUSLY WITH<br />
RED LED: Walk Test<br />
— QUICK FLASH FOR 1.6 SEC: RF<br />
transmitting<br />
5<br />
<br />
6<br />
— The<strong>se</strong> buttons are u<strong>se</strong>d to enter<br />
numbers.<br />
Disarm Key<br />
— Enter PIN Code and press once to<br />
disarm the system<br />
— Enter Master Code and press twice to<br />
enter Programm mode (in Disarm<br />
mode only).<br />
— The <strong>se</strong>cond Disarm key must be<br />
pres<strong>se</strong>d within 0.5 <strong>se</strong>conds.<br />
Arm Key<br />
— Enter PIN Code and press once to<br />
arm the system<br />
— In Programming mode, u<strong>se</strong> this key to<br />
abort<br />
<br />
Green LED’s indicating priority<br />
<strong>se</strong>quence is Programming mode > RF<br />
transmitting > <strong>GSM</strong> fault > <strong>UniAlert</strong><br />
fault > Device Fault.<br />
3<br />
Red LED<br />
— ON: Arm mode<br />
— FLASH: Alarm<br />
— FLASH ALTERNATELY WITH<br />
GREEN LED: Programming mode<br />
7<br />
8<br />
Buzzer<br />
Battery Switch<br />
1
1.2. In<strong>se</strong>rt <strong>GSM</strong> SIM Card<br />
9<br />
External <strong>GSM</strong> Antenna Jumper<br />
Swich (JP2)<br />
Jumper On<br />
The jumper link is in<strong>se</strong>rted<br />
connecting the two pins.<br />
Jumper Off<br />
The jumper link is removed<br />
or “parked” on one pin.<br />
— Jumper ON: External antenna disable<br />
(default)<br />
<strong>UniAlert</strong> features built-in <strong>GSM</strong> communication<br />
facility to make message reporting to the<br />
phone numbers pre-programmed within the<br />
system.<br />
To In<strong>se</strong>rt your SIM card:<br />
The <strong>GSM</strong> component is situated inside the<br />
Power Supply compartment as pointed out by<br />
the arrow below:<br />
— Jumper OFF: External antenna enable<br />
Internal PIR Detector Jumper<br />
Switch (JP1)<br />
— Jumper ON: Internal PIR enable<br />
(default)<br />
— Jumper OFF: Internal PIR disable<br />
Input/Output Contact Point & DC<br />
Terminals (refer to <strong>se</strong>ction 1.4)<br />
<strong>GSM</strong> SIM Card Ba<strong>se</strong><br />
<strong>GSM</strong> LED<br />
— SLOW FLASH (300ms On / 3.0s Off):<br />
Normal operation<br />
— QUICK FLASH (500ms On / 500ms<br />
Off): Searching for <strong>GSM</strong> reception/<br />
<strong>GSM</strong> fault<br />
<strong>GSM</strong> Antenna<br />
— For connecting an external <strong>GSM</strong><br />
antenna<br />
Mounting Holes<br />
Power Supply Compartment Cover<br />
Wall Mounting Bracket<br />
• Unlock the SIM card ba<strong>se</strong> by sliding the<br />
cover toward OPEN-backward direction.<br />
• Spring open the SIM card slot and in<strong>se</strong>rt<br />
your new SIM card.<br />
• Replace the SIM slot onto the ba<strong>se</strong> lightly.<br />
• Remember to lock the SIM card ba<strong>se</strong> by<br />
sliding the cover toward LOCK-forward<br />
direction.<br />
<br />
Beware to only in<strong>se</strong>rt or remove SIM<br />
card when <strong>UniAlert</strong> is completely<br />
depleted of any power residual.<br />
Plea<strong>se</strong> ensure the SIM card’s PIN<br />
code is disabled before in<strong>se</strong>rting into<br />
the <strong>UniAlert</strong>.<br />
2
1.3. The Power Supply<br />
A DC Terminal is eqipped to connect to a 12V<br />
power source.<br />
Rechargeable Battery<br />
• In addition to the DC power source,<br />
there is a rechargeable battery inside<br />
the <strong>UniAlert</strong> that <strong>se</strong>rves as a back up<br />
in ca<strong>se</strong> of power failure.<br />
• The battery u<strong>se</strong>d is a 4.8V 600mAH<br />
Ni-mH rechargeable battery pack.<br />
• During normal operation, the DC<br />
power source is u<strong>se</strong>d to supply power<br />
to the <strong>UniAlert</strong> and at the same time<br />
recharge the battery.<br />
• When the battery is fully charged, it<br />
can provide back-up power for a<br />
period of at least 6 hours. It takes<br />
approximately 48 hours to fully charge<br />
the battery.<br />
1.4. Input/Output & DC<br />
Terminals<br />
Connect the DC power and wired devices to<br />
the input/output contact points as shown below.<br />
Pins 5 & 6 DC 12V Power Output<br />
• A DC 12V 100mA Power Output Terminal<br />
is available to supply power to other wired<br />
devices if required.<br />
Pins 7 & 8 Arm/Disarm Input<br />
• For the wired device connected to<br />
Arm/Disarm Input Terminal:<br />
<br />
• The system enters Arm mode when<br />
the circuit is short.<br />
• The system enters Disarm mode<br />
when the circuit is open.<br />
Exit Timer is ineffective if the system<br />
is armed via this device. That is, the<br />
<strong>UniAlert</strong> enters Arm mode immediately<br />
when the circuit is short.<br />
Pins 9 & 10 Alarm Output (N.O.)<br />
• When an alarm is triggered, the device<br />
connected to Alarm Output will change<br />
the status from open to short (activate),<br />
until Alarm Length time is expired or when<br />
the <strong>UniAlert</strong> is disarmed. Then the status<br />
will change from short to open (deactivate)<br />
again.<br />
<br />
Alarm Output will not respond if Alarm<br />
Length is <strong>se</strong>t as 00 (disable).<br />
Pins 1 & 2 DC 12V Power Input<br />
• Connect a DC 12V power source to the<br />
Power Input Terminal.<br />
Pins 3 & 4 Alarm Input (N.C.)<br />
• When a wired <strong>se</strong>nsor/device is connected<br />
to the Alarm Input Terminal, the alarm will<br />
be triggered and a report will be <strong>se</strong>nt to<br />
the Central Monitoring Station when either<br />
the built-in PIR detector or this wired<br />
<strong>se</strong>nsor is triggered.<br />
3
1.5. How to install the <strong>UniAlert</strong><br />
Locating a suitable position for the<br />
<strong>UniAlert</strong><br />
• The <strong>UniAlert</strong> requires DC power and a<br />
constant <strong>GSM</strong> reception.<br />
• The <strong>UniAlert</strong> should be easily accessible,<br />
• The <strong>UniAlert</strong> should not be placed in a<br />
damp place, such as a bathroom.<br />
• The <strong>UniAlert</strong> should not be placed clo<strong>se</strong><br />
to any heat source, such as microwave<br />
ovens, which can reduce signal srength.<br />
• The <strong>UniAlert</strong> should not be located<br />
alongside other radio transmitting devices<br />
such as mobile phones, cordless phone or<br />
wireless computer network (WiFi) devices.<br />
Impontant: When drilling into a wall, ensure<br />
that there are no hidden cables or pipes.<br />
Mounting the <strong>UniAlert</strong><br />
The <strong>UniAlert</strong> is to be mounted on the wall. It is<br />
recommended to install the <strong>UniAlert</strong><br />
approximately 1.8 meters above ground level<br />
(top edge). The detection range is 10 meters at<br />
90° angle.<br />
In order to provide highest <strong>se</strong>curity in operating<br />
the system, <strong>UniAlert</strong> offers 2 levels of<br />
authorization. To program the system, you<br />
must enter Master Code.<br />
PIN Code<br />
• There are a total of 4 U<strong>se</strong>r PIN codes in<br />
the system. The PIN code is the 1st level<br />
of password.<br />
• U<strong>se</strong>r 1 PIN code cannot be deleted in<br />
any way.<br />
• 1234 is <strong>se</strong>t as default U<strong>se</strong>r 1 PIN code by<br />
the factory.<br />
• U<strong>se</strong>r 2 to 4 PIN codes are deactivated by<br />
factory default.<br />
<br />
U<strong>se</strong>r PIN codes may not be identical.<br />
If you <strong>se</strong>t the same number, the unit<br />
will emit 4 short beeps to alert the u<strong>se</strong>r.<br />
Master Code<br />
• The Master Code has the authorization to<br />
enter Programming mode and cannot be<br />
deleted in anyway.<br />
• 1111 is <strong>se</strong>t as default Master Code by the<br />
factory.<br />
<br />
Master Code and U<strong>se</strong>r PIN code may<br />
be the same.<br />
• Using the 2 holes of the wall mounting<br />
bracket as a template, mark off the holes’<br />
positions.<br />
• Drill 2 holes and in<strong>se</strong>rt the wall plugs if<br />
fixing into plaster or brick.<br />
• Hook the <strong>UniAlert</strong> onto the wall mounting<br />
bracket.<br />
1.6. Two-Level Passwords<br />
1.7. Getting Started<br />
4
Step 1. Find a suitable location for the<br />
<strong>UniAlert</strong> to be installed.<br />
Step 2. Apply power, and you will hear 2<br />
beeps. Plea<strong>se</strong> wait for approximately<br />
2 minutes for the system to <strong>se</strong>arch for<br />
a <strong>GSM</strong> reception; the Green LED<br />
flashes.<br />
Step 3. Wait for about a minute. When a <strong>GSM</strong><br />
reception is found, the Green LED<br />
becomes steadily on and the <strong>GSM</strong><br />
LED is flashes slowly (300ms On /<br />
3.0s Off). The system is now in<br />
Disarm mode.<br />
<br />
If after a few minutes, the Green LED<br />
(1s On / 1s Off) and the <strong>GSM</strong> LED<br />
(500ms On / 500ms Off) are still<br />
flashing, it means <strong>GSM</strong> activation has<br />
failed. Plea<strong>se</strong> check if the SIM card is<br />
properly in<strong>se</strong>rted and <strong>GSM</strong> reception<br />
is available.<br />
5<br />
2. Configuring Your
System<br />
2.1. Entering Programming<br />
Mode<br />
When the system is in Disarm mode, to enter<br />
the Programming mode, follow the steps below.<br />
Step 1. Enter the Master Code (1111 is <strong>se</strong>t as<br />
factory default).<br />
Step 2. Press the<br />
<br />
Disarm key twice.<br />
The <strong>se</strong>cond Disarm key must be<br />
pres<strong>se</strong>d within 0.5 <strong>se</strong>cond.<br />
Step 3. When successfully entered<br />
Programming mode, the Green & Red<br />
LED will flash alternately.<br />
Step 4. Start by pressing the Disarm key,<br />
followed by the programming<br />
command then the new <strong>se</strong>tting, and<br />
end with the Disarm key (plea<strong>se</strong><br />
refer to <strong>se</strong>ction 3.8 Programmig<br />
Command Table for more details).<br />
<br />
To change Master Code to 2222, enter:<br />
“ 102222 ”<br />
Where:<br />
10 = Command to <strong>se</strong>t Master Code<br />
2222 = new Master Code<br />
Step 5. 2 beeps will be heard to confirm the<br />
new <strong>se</strong>tting is accepted and stored.<br />
On the other hand, 4 beeps will be<br />
heard to indicate the new <strong>se</strong>tting is<br />
errounous or unacceptable.<br />
<br />
After Master code is programmed with<br />
new a number, plea<strong>se</strong> be reminded to<br />
enter the new number when<br />
accessing Programming mode<br />
afterwards.<br />
In Programming mode, press the<br />
Arm key at any time to abort.<br />
In Programming mode, if no key is<br />
pres<strong>se</strong>d within 3 minutes, the <strong>UniAlert</strong><br />
will automatically exit Programming<br />
mode to Disarm mode.<br />
If reporting or SMS remote<br />
programming is in progress, then 8<br />
beeps will be heard to alert the u<strong>se</strong>r<br />
that entering Programming mode is<br />
prohibited at the moment.<br />
2.2. Telephone Settings<br />
• This allows you to <strong>se</strong>t/change/delete the<br />
Central Monitoring Station or mobile<br />
telephone numbers for reporting purpo<strong>se</strong>.<br />
• A maximum of four numbers can be stored<br />
in priority order (in the order of 1, 2, 3, then<br />
4).<br />
<br />
At least one phone number must be<br />
entered, or the <strong>UniAlert</strong> will not dial out<br />
at alarm situations.<br />
Store/Change Tel. Numbers<br />
U<strong>se</strong> command 31 for Tel. Number 1, command<br />
32 for Tel. Number 2, and so on up to<br />
command 34 for Tel Number 4. The maximum<br />
length of a number is 20 digits.<br />
• To <strong>se</strong>nd SMS text message to u<strong>se</strong>r’s<br />
mobile phone, usage as below:<br />
3100267890001<br />
3200267890001<br />
3300267890001<br />
3400267890001<br />
Where:<br />
0 = SMS Text Message<br />
0267890001 = Telephone number<br />
<br />
All Alarm & Fault events will be<br />
reported to all numbers that are <strong>se</strong>t as<br />
0 (SMS Text Message).<br />
• To <strong>se</strong>nd SMS Contact ID (SCID) to Central<br />
Monitoring Station, usage as below:<br />
Where:<br />
31422220267890001<br />
32422220267890001<br />
33422220267890001<br />
34422220267890001<br />
6
4 = SMS Contact ID (SCID)<br />
2222 = Account number<br />
0267890001 = Telephone number<br />
<br />
Tel Numbers that are <strong>se</strong>t as 4 (SCID)<br />
have higher dialing priority than Tel<br />
numbers that are <strong>se</strong>t as 0 (SMS Text<br />
Message).<br />
<strong>UniAlert</strong> will dial the Tel Numbers for<br />
SMS Text Message after the Tel<br />
Numbers for SCID are finished.<br />
The reach number of SCID report is<br />
defined by Programming command 39.<br />
Delete Tel. Numbers<br />
To delete a telephone number, enter the<br />
respective command (e.g. 31 for Tel. Number<br />
1, 32 for Tel. Number 2) with null <strong>se</strong>tting.<br />
<br />
To delete Tel. Number 1, enter:<br />
“ 31 ”<br />
Set SCID Reach Number<br />
This is for you to <strong>se</strong>t how many Central Station<br />
Receivers should the <strong>UniAlert</strong>’s SCID reporting.<br />
Options available are One of TEL1-4 and All<br />
of TEL1-4.<br />
If you choo<strong>se</strong> One of TEL1-4, the <strong>UniAlert</strong> will<br />
try to dial the first SCID Tel number. If it failed,<br />
the <strong>UniAlert</strong> will try the next SCID Tel number.<br />
As long as one SCID Tel number is<br />
successfully reported, then the job is done.<br />
If you choo<strong>se</strong> All of TEL1-4, the <strong>UniAlert</strong> will<br />
need to successfully report to all of the SCID<br />
Tel numbers.<br />
U<strong>se</strong> command 39 with option 0 for One of<br />
TEL1-4 (if <strong>se</strong>t as SCID), and option 1 for All of<br />
TEL1-4 (if <strong>se</strong>t as SCID). Usage as below:<br />
390<br />
391<br />
Where:<br />
0 = One of TEL1-4 (if <strong>se</strong>t as SCID)<br />
1 = All of TEL1-4 (if <strong>se</strong>t as SCID)<br />
All of TEL1-4 is <strong>se</strong>t as factory default.<br />
2.3. PIN Code<br />
• There are 4 U<strong>se</strong>r PIN codes in total, and<br />
each consists of 4 digits. U<strong>se</strong>r 1 PIN code<br />
is activated as 1234 by factory default and<br />
cannot be deleted in any way.<br />
• U<strong>se</strong>r 2 to 4 PIN codes are deactivated by<br />
factory default.<br />
• All 4 U<strong>se</strong>r PIN codes are u<strong>se</strong>d to regularly<br />
arm/disarm the system.<br />
To Set/Change Own U<strong>se</strong>r PIN Code<br />
PIN codes can be re<strong>se</strong>t/changed by using the<br />
commands 11 to 14 to change the respective<br />
U<strong>se</strong>r PIN codes #1-4. Usage as below:<br />
Where:<br />
0 = Latch Report Off<br />
1 = Latch Report On<br />
1112340 (Latch Off)<br />
:<br />
1443211 (Latch On)<br />
U<strong>se</strong>r 1 PIN 1234 Latch Off is <strong>se</strong>t as factory<br />
default.<br />
<br />
Latch Report ON = Whenever the<br />
system is armed or disarmed, the<br />
<strong>UniAlert</strong> will <strong>se</strong>nd Contact ID code via<br />
SMS to notify the Central Monitoring<br />
Station, or SMS Text Message to<br />
u<strong>se</strong>r’s mobile phone (according to the<br />
Tel. <strong>se</strong>tting).<br />
Latch Reprot OFF = Whenever the<br />
system is armed or disarmed, the<br />
<strong>UniAlert</strong> will NOT <strong>se</strong>nd reporting(s) to<br />
notify the Central Monitoring Station<br />
nor the u<strong>se</strong>r.<br />
To Delete U<strong>se</strong>r PIN Code<br />
Except U<strong>se</strong>r 1 PIN code which is activated by<br />
factory default and can’t be deleted in any way,<br />
U<strong>se</strong>r PIN code 2, 3 and 4 can be deleted by<br />
enter the respective command (e.g. 12 for U<strong>se</strong>r<br />
2 PIN code, 13 for Tel. Number 2) with null<br />
<strong>se</strong>tting.<br />
<br />
To delete U<strong>se</strong>r 2 PIN code, enter:<br />
“ 12 ”<br />
2.4. Master Code<br />
7
• Master Code is u<strong>se</strong>d for accessing the<br />
Programming mode and it is <strong>se</strong>t as 1111 by<br />
factory default.<br />
• The Master code can not be deleted in<br />
anyway (same as the U<strong>se</strong>r 1 PIN code).<br />
• The Master Code is u<strong>se</strong>d to enter<br />
Programming mode only. In other ca<strong>se</strong>s,<br />
only U<strong>se</strong>r PIN code should be entered.<br />
• U<strong>se</strong> command 10 to <strong>se</strong>t/change own<br />
Master Code. Usage as below:<br />
101111<br />
1111 is <strong>se</strong>t as factory default.<br />
2.5. Entry Time<br />
The system goes into counting down period<br />
(away entry timer) when the PIR is triggered<br />
under Arm mode.<br />
During the counting down period, it is allowed<br />
to u<strong>se</strong> correct PIN code to disarm the alarm<br />
and the alarm reporting will not be <strong>se</strong>nt. On the<br />
other hand, if the correct PIN code has not<br />
been entered within the period, <strong>UniAlert</strong> rai<strong>se</strong>s<br />
an alarm and <strong>se</strong>nds an alarm report.<br />
To <strong>se</strong>t/change Entry Timer, u<strong>se</strong> command 22<br />
with options of 00 (alarm immediately), 01 (1<br />
<strong>se</strong>c), 02 (2 <strong>se</strong>c)…up to 70 (70 <strong>se</strong>c). Usage as<br />
below:<br />
2200<br />
2270<br />
Where:<br />
00 = 0 <strong>se</strong>c (alarm immediately)<br />
70 = 70 (70 <strong>se</strong>cs)<br />
30 <strong>se</strong>c is <strong>se</strong>t as factory default.<br />
<strong>UniAlert</strong>, Remote Controller (RC) or Remote<br />
Keypad (KP), an Away exit timer starts<br />
counting down.<br />
During the counting down period, pressing the<br />
Arm Button of the RC can restart the counting.<br />
In addition, it is allowed to u<strong>se</strong> correct PIN<br />
code or press Disarm Button of the RC to stop<br />
the counting and return to Disarm mode.<br />
To <strong>se</strong>t/change Exit Timer, u<strong>se</strong> command 23<br />
with options of 00 (alarm immediately), 01 (1<br />
<strong>se</strong>c), 02 (2 <strong>se</strong>c)…up to 70 (70 <strong>se</strong>c). Usage as<br />
below:<br />
2300<br />
2370<br />
Where:<br />
00 = 0 <strong>se</strong>c (arm immediately)<br />
70 = 70 (70 <strong>se</strong>cs)<br />
30 <strong>se</strong>c is <strong>se</strong>t as factory default.<br />
<br />
Exit Timer is ineffective if the<br />
Home/Partial Arm Button of the RC is<br />
pres<strong>se</strong>d. That is, the <strong>UniAlert</strong> enters<br />
Arm mode immediately when the<br />
Home/Partial Arm Button of the RC is<br />
pres<strong>se</strong>d.<br />
2.6. Exit Time<br />
While the system gets into Arm mode by<br />
8<br />
2.7. Alarm Length<br />
This is for you to <strong>se</strong>lect the internal siren
duration when an alarm is activated.<br />
To <strong>se</strong>t/change Alarm Length, u<strong>se</strong> command 21<br />
with options of 00 (disable), 01 (1 min), up to<br />
15 (15 mins) in 1-min increments. Usage as<br />
below:<br />
Where:<br />
00 = Disable<br />
15 = 15 minutes<br />
2100<br />
2115<br />
3 min is <strong>se</strong>t as factory default.<br />
• If Disable is <strong>se</strong>lected, when <strong>UniAlert</strong><br />
receives an alarm signal, the internal siren<br />
and external sirens (SR & BX) will not rai<strong>se</strong><br />
an alarm sound. Alarm Output is also<br />
disabled.<br />
• When a 2 nd alarm is triggered during the<br />
Alarm Length period, Alarm Length will not<br />
be extended/incremented.<br />
• If SR/BX’s alarm length is longer than the<br />
<strong>UniAlert</strong>’s, the system gives priority to the<br />
<strong>UniAlert</strong> (e.g. when the SR/BX’s alarm<br />
length is <strong>se</strong>t as 3 mins, and the <strong>UniAlert</strong>’s<br />
alarm length is <strong>se</strong>t as 1 min, both alarm<br />
siren stop at 1 min when alarm is triggered;<br />
however, the SR/BX’s LED keeps flashing<br />
until 3 mins is expired).<br />
and no siren/warning sound will be made at all<br />
times.<br />
• To disable the internal siren, u<strong>se</strong> command<br />
24 with option 0. Usage as below:<br />
240<br />
• To enable the internal siren, u<strong>se</strong> command<br />
24 with option 1. Usage as below:<br />
241<br />
Enable is <strong>se</strong>t as factory default.<br />
<br />
If <strong>se</strong>t as Disable, when <strong>UniAlert</strong><br />
receives an alarm/status/fault signal,<br />
no sound will be made from the<br />
internal siren. However, external<br />
sirens (SR & BX) and Alarm Output<br />
are not affected and will continue to<br />
perform as programmed.<br />
2.8. Internal Siren<br />
The <strong>UniAlert</strong>’s internal siren can be disabled,<br />
9<br />
2.8. Add/Remove Device<br />
A total of 20 devices can be leant into the
system. Each device occupies a zone number.<br />
2.8.1. Add Devices<br />
Step 1. To learn in a device, u<strong>se</strong> command 91<br />
then followed by a zone number.<br />
Usage as below:<br />
Where:<br />
01 = Zone 1<br />
20 = Zone 20<br />
<br />
9101<br />
9120<br />
If the zone is already in u<strong>se</strong>, the<br />
<strong>UniAlert</strong> will emit a 2-tone sound to<br />
indicate.<br />
Step 2. The <strong>UniAlert</strong> is now in Learn mode.<br />
Press the test/learn button on the<br />
device or any button on the Remote<br />
Controller.<br />
Step 3. If a signal is received, the <strong>UniAlert</strong> will<br />
beep twice to confirm then exit Learn<br />
mode automatically.<br />
<br />
If a device has been previously learnt<br />
into other zone, the <strong>UniAlert</strong> will beep<br />
once to indicate and stays in Learn<br />
mode for you to re-enter the command<br />
with an available zone number.<br />
Time-out for Learn mode is 10<br />
<strong>se</strong>conds, or 5 <strong>se</strong>conds for incomplete<br />
command entered (e.g. entered “ 91”<br />
only, with no sub<strong>se</strong>quent zone #).<br />
When exiting Learn mode, 4 beeps<br />
will be heard to indicate.<br />
<br />
<br />
<br />
Carbon Monoxide --- CO<br />
Water Sensor --- WS<br />
Wrist/Pendant Transmitter ---<br />
WTR<br />
For Door Contact (DC), the attribute<br />
is <strong>se</strong>t fixed to Entry.<br />
<br />
<br />
<br />
When the system is in Away<br />
arm mode, if an Entry Door<br />
Contact is triggered, the<br />
<strong>UniAlert</strong> will start an entry period<br />
to give enough time to disarm<br />
the system.<br />
After the delay period is expired<br />
and no correct PIN code is<br />
entered to disarm the system,<br />
the <strong>UniAlert</strong> will respond with a<br />
Burglar Alarm and an event<br />
code 130 will be reported.<br />
When the system is in Alarm off<br />
mode, if an Entry Door Contact<br />
is triggered, the Control Panel<br />
will make a ding-dong sound for<br />
Door Chime.<br />
For PIR (IR) and External PIR (EIR),<br />
the attribute is <strong>se</strong>t fixed to Burglar.<br />
<br />
When the system is in Away<br />
arm mode, if a Burglar IR/EIR<br />
is triggered, the <strong>UniAlert</strong> will<br />
respond with a Burglar Alarm<br />
and an event code 130 will be<br />
reported.<br />
The categories of devices are listed as<br />
followings:<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Remote Controller --- RC<br />
Remote Keypad --- KP<br />
Panic Button --- PB<br />
Night Switch --- NS<br />
Door Contact --- DC<br />
PIR Sensor --- IR<br />
External PIR --- EIR<br />
<br />
Smoke Detector --- SD<br />
10<br />
2.8.2. Remove Devices<br />
Adding a device for a <strong>se</strong>cond time is prohibited
unless it is removed from the system first.<br />
• To remove all devices at once, u<strong>se</strong><br />
command 80 as below:<br />
8099<br />
• To remove a particular device, u<strong>se</strong><br />
command 81 followed by the zone number.<br />
Usage as below:<br />
Where:<br />
01 = Zone 1<br />
20 = Zone 20<br />
<br />
8001<br />
8020<br />
If the zone number does not exist (no<br />
device learnt), the <strong>UniAlert</strong> will emit a<br />
4 beeps to indicate.<br />
When the device(s) is/are successfully<br />
removed, the <strong>UniAlert</strong> will beep twice to<br />
confirm.<br />
2.9. Program Siren<br />
<br />
For outdoor Bell Box BX-8 and/or<br />
indoor Siren SR-8, at least one device<br />
must be learnt in first in order to<br />
program siren.<br />
If an outdoor Bell Box (BX) or indoor Siren (SR)<br />
is to be included in the system, it should be<br />
programmed first by the <strong>UniAlert</strong>, so that the<br />
<strong>UniAlert</strong> can communicate with the<strong>se</strong> auxiliary<br />
devices.<br />
Learn Bell Box (BX) / Siren (SR)<br />
Step 1. Put the desired auxiliary device into<br />
learn mode (plea<strong>se</strong> refer to its<br />
individual Operation Manual). U<strong>se</strong><br />
command 92 with option 1. Usage as<br />
below:<br />
921<br />
to all devices simultaneously. The<br />
BX/SR should respond by activating<br />
its siren and/or strobe light<br />
momentarily, and the <strong>UniAlert</strong> will also<br />
beep twice to confirm.<br />
Step 3. Place the<strong>se</strong> auxiliary devices out of<br />
learn mode. Adding them into the<br />
system is now complete.<br />
<br />
If any of the<strong>se</strong> devices does not<br />
respond, make sure that the device is<br />
in learn mode and re-enter the<br />
command.<br />
<br />
For the following <strong>se</strong>ttings/commands,<br />
whichever option is <strong>se</strong>lected, when the<br />
<strong>UniAlert</strong> transmits the signal, all added<br />
sirens will simultaneously receive the<br />
signal and will all act accordingly.<br />
Siren Tamper On, Siren Tamper Off<br />
The BX/SR tamper switch can be enabled and<br />
disabled remotely. This is u<strong>se</strong>d especially<br />
when replacing BX/SR battery.<br />
• To disable the BX/SR tamper switch, u<strong>se</strong><br />
command 92 with option 3. Usage as<br />
below:<br />
923<br />
All added BX/SR will temporarity lo<strong>se</strong> their<br />
tamper protection simultanously.<br />
• To enable the BX/SR tamper switch, u<strong>se</strong><br />
command 92 with option 2. Usage as<br />
below:<br />
922<br />
All added BX/SR will be enable their<br />
tamper protection simultanously.<br />
When the command is accepted, the <strong>UniAlert</strong><br />
will beep twice to confirm. The BX/SR will also<br />
emit a beep to confirm. If no sound is heard<br />
from BX/SR within 10 <strong>se</strong>c, that means no<br />
signal is received. Plea<strong>se</strong> re<strong>se</strong>nd the command.<br />
Step 2. The <strong>UniAlert</strong> will transmit learning code<br />
<br />
The Siren tamper disable will<br />
11
automatically revert to On after about<br />
an hour if not switched back.<br />
Confirm On, Confirm Off<br />
The BX/SR can be enabled for arming and<br />
disarming confirmation, that beeps are emitted<br />
from the siren to validate that the system has<br />
been armed and disarmed.<br />
• To disable the BX/SR siren confirmation,<br />
u<strong>se</strong> command 92 with option 5. Usage as<br />
below:<br />
925<br />
• To enable the BX/SR siren confirmation,<br />
u<strong>se</strong> command 92 with option 4. Usage as<br />
below:<br />
924<br />
When the command is accepted, the <strong>UniAlert</strong><br />
will beep twice to confirm. The <strong>UniAlert</strong> will<br />
beep twice to confirm. The BX/SR will also emit<br />
a beep to confirm. If no sound is heard from<br />
BX/SR within 10 <strong>se</strong>c, that means no signal is<br />
received. Plea<strong>se</strong> re<strong>se</strong>nd the command.<br />
siren/warning sound will be made at all times.<br />
• To disable the BX/SR, u<strong>se</strong> command 92<br />
with option 0. Usage as below:<br />
920<br />
• To enable the BX/SR again, u<strong>se</strong> command<br />
92 with option 1. Usage as below:<br />
921<br />
When the command is accepted, the <strong>UniAlert</strong><br />
will beep twice to confirm.<br />
Entry/Exit Sound On, Entry/Exit Sound Off<br />
The BX/SR can be enabled or disabled to<br />
sound the Entry/Exit delay warning beeps.<br />
• To disable the BX/SR entry/exit sound, u<strong>se</strong><br />
command 92 with option 7. Usage as<br />
below:<br />
927<br />
• To enable the BX/SR entry/exit sound, u<strong>se</strong><br />
command 92 with option 6. Usage as<br />
below:<br />
926<br />
When the command is accepted, the <strong>UniAlert</strong><br />
will beep twice to confirm. The <strong>UniAlert</strong> will<br />
beep twice to confirm. The BX/SR will also emit<br />
a beep to confirm. If no sound is heard from<br />
BX/SR within 10 <strong>se</strong>c, that means no signal is<br />
received. Plea<strong>se</strong> re<strong>se</strong>nd the command.<br />
Disable Bell Box (BX) / Siren (SR)<br />
All BX/SR can be disabled and no<br />
12<br />
2.10. Remote Programming<br />
via SMS Commands
The <strong>UniAlert</strong> can also be programmed<br />
remotely via SMS commands. All programming<br />
options require SMS commands to be <strong>se</strong>nt in<br />
specific formats. All commands require a SMS<br />
Program Word (SMS P-Word, default PROG,<br />
and a SMS Keyword (default SET). Plea<strong>se</strong><br />
refer to <strong>se</strong>ction 3.8 Programmig Command<br />
Table for more details.<br />
All below instructions/examples are ba<strong>se</strong>d on<br />
factory default. U<strong>se</strong>r is to substitute own P-<br />
Word and Keyword if changed.<br />
2.10.1. SMS Program Word (P-Word)<br />
The default SMS P-Word can be changed to<br />
own word by using command 1A. A maximum<br />
of 15 characters is allowed. Usage as below:<br />
1AJACK<br />
PROG is <strong>se</strong>t as factory default.<br />
Once this SMS command is received by<br />
<strong>UniAlert</strong>, the previous P-Word, PROG, is<br />
replaced by JACK.<br />
2.10.2. SMS Keyword<br />
To <strong>se</strong>nd remote commands to system via SMS<br />
message, a personalized password is required<br />
for <strong>UniAlert</strong> to recognize your authority.<br />
The default SMS Keyword can be changed to<br />
own word by using command 1B. A maximum<br />
of 10 characters is allowed. Usage as below:<br />
1BKEY<br />
SET is <strong>se</strong>t as factory default.<br />
Once this SMS command is received by<br />
<strong>UniAlert</strong>, the previous SMS Keyword, SET, is<br />
replaced by KEY.<br />
The text you entered in SMS Header will<br />
display be displayed in each SMS alarm<br />
message reported to your mobile phone.<br />
For example, if you enter your address in SMS<br />
Header, your address will be shown in SMS<br />
alarm messages; the format is (your address,<br />
Panic Alarm)<br />
For <strong>se</strong>nding a SMS alarm reporting to your<br />
mobile phone, enter your SMS Header by<br />
using command 1C. A maximum of 64<br />
characters is allowed. Usage as below:<br />
1CADDRESS<br />
ALARM UNIALERT is <strong>se</strong>t as factory default.<br />
Once this SMS command is received by<br />
<strong>UniAlert</strong>, the previous SMS Header, ALARM<br />
UNIALERT, is replaced by ADDRESS.<br />
<br />
The saved SMS Header will be <strong>se</strong>nt<br />
along with the SMS status message to<br />
mobile phone.<br />
If no SMS Header is programmed,<br />
only the SMS alarm message will be<br />
<strong>se</strong>nt to mobile phone.<br />
2.11. Walk Test (Local<br />
Programming Only)<br />
• U<strong>se</strong> command 93 to start Walk Test.<br />
Usage as below:<br />
93<br />
When the command is accepted, the<br />
<strong>UniAlert</strong> will beep twice to confirm.<br />
• By pressing the test button on the device,<br />
Remote Controller, or triggering the <strong>se</strong>nsor,<br />
if the <strong>UniAlert</strong> receives the signal, it will<br />
emit a 2-tone ding-dong sound to confirm.<br />
• Once the device testing is satisfactory,<br />
press Disarm key once to end Walk Test.<br />
2.10.3. SMS Header<br />
13
2.12. Exiting Programming<br />
Mode<br />
Once programming is completed, u<strong>se</strong><br />
command 99 to exit programming mode.<br />
Usage as below:<br />
99<br />
When the command is accepted, the <strong>UniAlert</strong><br />
will beep twice to confirm.<br />
<br />
In Programming mode, if no key is<br />
pres<strong>se</strong>d or no RF signal is received<br />
within 3 minutes, the <strong>UniAlert</strong> will emit<br />
5 beeps and automatically exit<br />
Programming mode to Disarm mode.<br />
14<br />
3. Operation
3.1. Away (Alarm On) Mode<br />
When the system is in Disarm (Alarm Off)<br />
mode, and arming the system is wished,<br />
plea<strong>se</strong> follow the steps below:<br />
Step 1. Enter a U<strong>se</strong>r PIN code (U<strong>se</strong>r 1 PIN<br />
code 1234 is <strong>se</strong>t as factory default).<br />
Step 2. Press the<br />
Arm key.<br />
Step 3. The defined EXIT Delay is counting<br />
down. During the EXIT Delay period,<br />
the exit sound plays, unless it has<br />
been cho<strong>se</strong>n to switch off.<br />
<br />
During the Exit Delay Count Down<br />
Period:<br />
• Exit Delay Sound:<br />
If it is <strong>se</strong>t as 01-70 <strong>se</strong>c, there will be<br />
a beep at every <strong>se</strong>cond, until the<br />
Count Down timer expires.<br />
If it is <strong>se</strong>t as 00 (Disable), a silent<br />
count down will be performed.<br />
• Latch Report Option:<br />
If it is <strong>se</strong>t as ON, an Arming report<br />
will be <strong>se</strong>nt to Central Monitoring<br />
Station.<br />
If it is <strong>se</strong>t as OFF, no report will be<br />
<strong>se</strong>nt.<br />
Step 4. When Exit Delay timer expires, the<br />
<strong>UniAlert</strong> will perform a long beep and<br />
the system is now in Arm Mode.<br />
<br />
The system can also be armed by<br />
pressing the Arm button on the<br />
Remote Controller.<br />
Exit Timer is ineffective if the<br />
Home/Partial Arm Button of the<br />
Remote Controller (RC) is pres<strong>se</strong>d.<br />
That is, the <strong>UniAlert</strong> enters Arm mode<br />
immediately when the Home/Partial<br />
Arm Button of the RC is pres<strong>se</strong>d.<br />
The Exit Delay can be stopped by disarming<br />
the system.<br />
Step 1. Key in your U<strong>se</strong>r PIN code, followed<br />
by Disarm key.<br />
Step 2. If the U<strong>se</strong>r PIN code is correct, then<br />
the exit sound will be stopped.<br />
<br />
The Exit Delay can also be stopped by<br />
pressing the Disarm button on the<br />
Remote Controller.<br />
If the Exit Delay period times out<br />
before the code can be entered, the<br />
system will be armed.<br />
3.1.2. Extend the Exit Delay<br />
During the Exit Delay period, the delay time<br />
can be extended. Each time the delay time is<br />
extended, the timer tarts counting from the<br />
beginning.<br />
Step 1. Key in your U<strong>se</strong>r PIN code, followed<br />
by Arm key.<br />
Step 2. If the U<strong>se</strong>r PIN code is correct, you<br />
will continue to hear the exit sound.<br />
<br />
The Exit Delay can also be extended<br />
by pressing the Arm button on the<br />
Remote Controller.<br />
While you arm the system, if the<br />
<strong>UniAlert</strong> is triggered (e.g. motion<br />
detected), arming is also prohibited.<br />
3.2. Disarm (Alarm Off) Mode<br />
When the system is in Arm mode, enter the<br />
U<strong>se</strong>r PIN Code and press Disarm key. If the<br />
PIN code is correct, the systeml will emit 2<br />
short beeps and return to Disarm mode.<br />
<br />
When the system is Armed, pressing<br />
the Disarm button on the Remote<br />
Controller can also disarm the system.<br />
3.1.1. Stopping the Exit Delay<br />
15<br />
3.3. Stop the Alarm<br />
During any alarm, the <strong>UniAlert</strong> wil sound its<br />
siren and report to the Phone number
programmed previously.<br />
During an alarm, to stop the siren:<br />
Step 1. Key in your U<strong>se</strong>r PIN code, followed<br />
by Disarm key.<br />
Step 2. If the U<strong>se</strong>r PIN code is correct, then<br />
the alarm sound will be stopped.<br />
<br />
When an alarm is rai<strong>se</strong>d, press the<br />
Disarm button on the Remote<br />
Controller will also stop the alarm.<br />
3.4. Dual-Key Function<br />
You may manually trigger Panic, Fire, and<br />
Emergency alarms if needed.<br />
• Panic Alarm — Press & Hold 1 key + 3<br />
key at the same time for 3 <strong>se</strong>conds.<br />
• Fire Alarm — Press & Hold 4 key + 6 key<br />
at the same time for 3 <strong>se</strong>conds.<br />
• Emergency Alarm — Press & Hold 7 key +<br />
9 key at the same time for 3 <strong>se</strong>conds.<br />
To stop the<strong>se</strong> alarms, simply follow the normal<br />
disarm procedure.<br />
3.5. Faulty Situations<br />
• The <strong>UniAlert</strong> is capable of detecting<br />
following fault events:<br />
<br />
<br />
<br />
<br />
AC Power Fail<br />
<strong>UniAlert</strong>/Device Low Battery<br />
<strong>UniAlert</strong>/Device Tamper<br />
<strong>GSM</strong> not ready<br />
• In ca<strong>se</strong> any fault condition is detected, the<br />
<strong>UniAlert</strong> will respond with a Fault alarm<br />
respectively according to the nature of the<br />
faulty event.<br />
• Device sabotaged<br />
• The <strong>UniAlert</strong> and Remote Keypad<br />
are Tamper protected.<br />
<br />
<strong>UniAlert</strong><br />
A Tamper switch protects <strong>UniAlert</strong><br />
from any removal attempts away<br />
from its wall mounting bracket.<br />
• Device low battery<br />
If the battery voltage of Remote Keypad,<br />
or Remote Controller is low, a Device Low<br />
Battery message will be reported.<br />
• <strong>GSM</strong> not ready<br />
If the SIM card is found missing,<br />
improperly in<strong>se</strong>rted, PUK/PIN code<br />
locked, no <strong>GSM</strong> reception, or faulty, the<br />
Green LED will flash to indicate.<br />
3.5.1. Fault Event Respon<strong>se</strong><br />
• In all modes, the <strong>UniAlert</strong> and the external<br />
sirens will NOT sound audible siren for<br />
fault event (except Sabotaged/Tamper<br />
alarm).<br />
• In all modes, when AC power<br />
failure/restore, Device low battery/restore,<br />
or <strong>UniAlert</strong>/Device Tamper open/restore,<br />
the <strong>UniAlert</strong> will <strong>se</strong>nd fault report by SMS<br />
(both SMS Text message to u<strong>se</strong>r and<br />
SCID to the Central Monitoring Station).<br />
Once the fault is restored, the <strong>UniAlert</strong> will<br />
also report the restore event by SMS to<br />
the telephone numbers.<br />
• AC Power Fail<br />
The Green LED will flash slowly<br />
(60ms On / 2.5s Off) and an AC<br />
Fault Report will be <strong>se</strong>nt after 30<br />
<strong>se</strong>c.<br />
When AC is restored for more than<br />
30 <strong>se</strong>c, an AC Restore Report will<br />
be <strong>se</strong>nt and the Green LED will<br />
stop flashing.<br />
• <strong>UniAlert</strong> Low Battery<br />
When the <strong>UniAlert</strong> low battery is<br />
detected, Green LED will flash<br />
slowly (60ms On / 2.5s Off) and a<br />
Low Battery Report will be <strong>se</strong>nt<br />
after 30 <strong>se</strong>c.<br />
When Low Battery is restored for<br />
more than 30 <strong>se</strong>c, a Low Battery<br />
Restore Report will be <strong>se</strong>nt and the<br />
Green LED will stop flashing.<br />
• Sensor Low Battery<br />
When low battery is detected on<br />
any <strong>se</strong>nsor, Green LED will flash<br />
quickly (60ms On / 500ms Off) and<br />
a Device Low Battery Report will be<br />
<strong>se</strong>nt immediately.<br />
When Low Battery is restored for<br />
more than 30 <strong>se</strong>c, a Low Battery<br />
16
Restore Report will be <strong>se</strong>nt and the<br />
Green LED will stop flashing.<br />
• Panel Sabotaged<br />
If the Tamper switch on the <strong>UniAlert</strong><br />
is triggered, Green LED will flash<br />
(ON 60 ms / OFF 2.5s).<br />
• Sensor Sabotaged<br />
If the Tamper switch on any <strong>se</strong>nsor,<br />
Remote Keypad, or Bell Box is<br />
triggered, Green LED will flash (ON<br />
60ms / OFF 500ms).<br />
The format of SMS CID message is:<br />
Where<br />
ACCT MT QXYZ GG CCC<br />
ACCT = 4 Digit Account number (0-9)<br />
MT = Message Type, 18H.<br />
Q<br />
= Event qualifier, which gives<br />
specific event information:<br />
XYZ = Event code (3 Hex digits 0-9)<br />
GG<br />
= Group or Partition number (00H)<br />
3.6. Remote Commanding<br />
(SMS Only)<br />
The <strong>UniAlert</strong> can be controlled by Remote<br />
Control Commands <strong>se</strong>nt via SMS messages.<br />
Plea<strong>se</strong> be reminded to change the language<br />
<strong>se</strong>tting of your mobile phone to English<br />
prior to proceed.<br />
• SMS Remote Control Command Table<br />
Control<br />
Command<br />
Result<br />
CCC<br />
= Zone Number<br />
000 UNIALERT<br />
001 Zone 1<br />
002 Zone 2<br />
003 Zone 3<br />
……………<br />
……………<br />
018 Zone 18<br />
019 Zone 19<br />
020 Zone 20<br />
021<br />
41<br />
(option 1)<br />
41<br />
(option 0)<br />
Arm<br />
Disarm<br />
All below instructions/examples are ba<strong>se</strong>d on<br />
factory default. U<strong>se</strong>r is to substitute own SMS<br />
Keywor and U<strong>se</strong>r PIN code if changed.<br />
• To <strong>se</strong>nd SMS message to command the<br />
<strong>UniAlert</strong> to enter Arm/Disarm Mode, the<br />
usage is:<br />
Where:<br />
SET = SMS Keyword<br />
“_” = Space<br />
1234 = U<strong>se</strong>r PIN code<br />
41 = Arm mode<br />
1 = Option 1, Arm<br />
0 = Option 0, Disarm<br />
SET_1234_*41_1*<br />
SET_1234_*41_0*<br />
3.7. Message Composition<br />
17
3.8. Programming Command Table<br />
Programming commands, usages, and defaults are summarized as below:<br />
COMMAND USAGE ACK DEFAULT<br />
10<br />
11<br />
12<br />
13<br />
Set Master PIN code (4 digits, 0000-9999)<br />
(The code cannot be deleted.)<br />
Set U<strong>se</strong>r 1 PIN code (4 digits, 0000-9999)<br />
Latch Report Off (4 digits, 0000-9999) + 0<br />
Latch Report On (4 digits, 0000-9999) + 1<br />
(The code cannot be deleted.)<br />
Set U<strong>se</strong>r 2 PIN code (4 digits, 0000-9999)<br />
Latch Report Off (4 digits, 0000-9999) + 0<br />
Latch Report On (4 digits, 0000-9999) + 1<br />
Delete the code (no digit)<br />
Set U<strong>se</strong>r 3 PIN code (4 digits, 0000-9999)<br />
Latch Report Off (4 digits, 0000-9999) + 0<br />
Latch Report On (4 digits, 0000-9999) + 1<br />
Delete the code (no digit)<br />
bi-bi 1111<br />
bi-bi<br />
1234<br />
(0: Latch Report Off)<br />
bi-bi ---<br />
bi-bi ---<br />
14<br />
Set U<strong>se</strong>r 4 PIN code (4 digits, 0000-9999)<br />
Latch Report Off (4 digits, 0000-9999) + 0<br />
Latch Report On (4 digits, 0000-9999) + 1<br />
bi-bi ---<br />
Delete the code (no digit)<br />
1A Set SMS P-Word (15 characters) PROG<br />
1B Set SMS Keyword (10 characters) SET<br />
1C Set SMS Header (64 characters) ALARM <strong>UniAlert</strong> <strong>GSM</strong><br />
21 Set Alarm Length (2 digits, 00-15, unit: minute) bi-bi 3 minutes<br />
22 Set Entry Time (2 digits, 00-70, unit: <strong>se</strong>cond) bi-bi 30 <strong>se</strong>conds<br />
23 Set Exit Time (2 digits, 00-70, unit: <strong>se</strong>cond) bi-bi 30 <strong>se</strong>conds<br />
24<br />
Set internal siren On/Off<br />
0: Disable internal siren<br />
1: Enable internal siren<br />
bi-bi<br />
1<br />
(On)<br />
31<br />
Set SMS Telephone number 1<br />
Set Text: 0 + TEL (20 digits)<br />
Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20digits)<br />
Delete the number (no digit)<br />
bi-bi<br />
No number<br />
32<br />
Set SMS Telephone number 2<br />
Set Text: 0 + TEL (20 digits)<br />
Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20 digits)<br />
Delete the number (no digit)<br />
bi-bi<br />
No number<br />
33<br />
Set SMS Telephone number 3<br />
Set Text: 0 + TEL (20 digits)<br />
Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20 digits)<br />
Delete the number (no digit)<br />
bi-bi<br />
No number<br />
34<br />
Set SMS Telephone number 4<br />
Set Text: 0 + TEL (20 digits)<br />
Set SCID: 4 + Account No.(4 digits, 0000-9999) + TEL (20 digits)<br />
Delete the number (no digit)<br />
bi-bi<br />
No number<br />
39<br />
SCID reach:<br />
0: one of the TEL 1-4 (if <strong>se</strong>t as SCID)<br />
1: all the TEL 1-4 (if <strong>se</strong>t as SCID)<br />
bi-bi<br />
1<br />
(all)<br />
41<br />
Set Arm mode (Remote control via SMS)<br />
1: Arm<br />
0: Disarm<br />
80<br />
81<br />
Remove all device<br />
99<br />
Remove a particular device:<br />
Zone number (2 digits, 01-20)<br />
If the zone does not exist, ---> do-di<br />
bi-bi ---<br />
bi-bi ---<br />
18
COMMAND USAGE ACK DEFAULT<br />
91<br />
Learn-in device:<br />
Zone number (2 digits, 01-20) + press “Disarm” then 10 <strong>se</strong>c time out,<br />
otherwi<strong>se</strong> 5 <strong>se</strong>c time out for incomplete command, time out bi-bi-bi-bi<br />
If successfully learnt, ---> bi-bi and exit learn mode<br />
If zone number is in u<strong>se</strong>, ---> do-di<br />
If the device is already learnt in other zone, ---> bi and continue to stay in learn mode<br />
bi-bi<br />
No device<br />
92<br />
93<br />
97<br />
98<br />
Program Siren:<br />
0: Disable BX/SR<br />
1: Learn Siren<br />
2: Siren Tamper On<br />
3: Siren Tamper Off<br />
4: Confirm On<br />
5: Confirm Off<br />
6: Entry/Exit Sound On<br />
7: Entry/Exit Sound Off<br />
Walk Test: signal received --> ding-dong<br />
(press “Disarm” to end Walk Test)<br />
0: Re<strong>se</strong>t Master Code to factory default 1111<br />
1: Re<strong>se</strong>t U<strong>se</strong>r 1 PIN code to factory default 1234, and<br />
U<strong>se</strong>rs PIN 2-4 deactivated<br />
2: Re<strong>se</strong>t SMS P-Word/SMS Keyword, and SMS Header to factory default<br />
Re<strong>se</strong>t all to factory default<br />
2580<br />
bi-bi<br />
bi-bi<br />
Disable<br />
bi-bi ---<br />
bi-bi ---<br />
99 Exit programming mode bi-bi ---<br />
<br />
In Programming mode, press<br />
Arm key at anytime to abort <strong>se</strong>ttting.<br />
Commands 1A to 1C,41 are for SMS only, and Commands 80 to 99 are for Keypad only.<br />
All other Commands can be u<strong>se</strong>d by both SMS & Keypads.<br />
<br />
Examples of remote SMS commanding is as shown below:<br />
• To remote Arm/Disarm:<br />
If SMS Keyword is “SET”, and U<strong>se</strong>r code is “1234”:<br />
To Arm : SET_1234_*41_1*<br />
To Disarm: SET_1234_*41_0*<br />
• To remote program:<br />
If SMS P-Word is “PROG”, and Master Code is “1111”:<br />
To <strong>se</strong>t TEL-1 for SMS (Text): PROG_1111_*31_0_0911907086*<br />
To <strong>se</strong>t TEL-2 for SMS (SCID): PROG_1111_*32_4_5678_0911907086*<br />
where “_” is a space<br />
19
4. Appendix<br />
4.1. Re<strong>se</strong>t Procedure<br />
Re<strong>se</strong>t All to Factory Default<br />
Setting<br />
• When the system is off, and Tamper is<br />
protruding (open):<br />
Step 1. Press and hold the 3 key while<br />
powering up. Relea<strong>se</strong> the button when<br />
a long beep is heard.<br />
Step 2. Enter 258009. A ding-dong sound will<br />
be heard to confirm all <strong>se</strong>ttings are<br />
restored to factory default.<br />
Step 3. 2 short beeps will then be heard to<br />
indicate the system is now in Disarm<br />
mode:<br />
• When the system on and is in Disarm<br />
mode:<br />
Step 1. Enter Programming mode by keying in<br />
the Master Code then press the<br />
Disarm key twice.<br />
<br />
The <strong>se</strong>cond Disarm key must be<br />
pres<strong>se</strong>d within 0.5 <strong>se</strong>cond.<br />
Step 2. When successfully entered<br />
Programming mode, the Green & Red<br />
LED will flash alternately.<br />
Step 3. Enter the command by pressing<br />
“ 982580 ”.<br />
Step 4. Exit Programming mode by pressing<br />
“ 99 ”.<br />
<br />
For all programming commands<br />
entered, 2 beeps will be heard to<br />
confirm the command is accepted and<br />
executed. On the other hand, 4 beeps<br />
will be heard to indicate the command<br />
is errounous or unacceptable.<br />
Once the Factory Re<strong>se</strong>t is executed,<br />
all the programmed data are returned<br />
to its default value and all the devices<br />
having been learnt-in are removed.<br />
You have to do the programming and<br />
learn in the device one by one again.<br />
Re<strong>se</strong>t Only Master Code<br />
Repeat the above procedure except step 3:<br />
Step 3. Enter command 97 with option 0, by<br />
pressing “ 970 ”.<br />
<br />
Once this command is executed, the<br />
Master Code is re<strong>se</strong>t to 1111.<br />
Re<strong>se</strong>t Only U<strong>se</strong>r PIN Codes<br />
Repeat the above procedure except step 3:<br />
Step 3. Enter command 97 with option 1, by<br />
pressing “ 971 ”.<br />
<br />
Once this command is executed, U<strong>se</strong>r<br />
1 PIN code is re<strong>se</strong>t to 1234. U<strong>se</strong>r 2 to<br />
4 PIN codes are deactivated.<br />
Re<strong>se</strong>t Only SMS P-Word, SMS<br />
Keyword, and SMS Header<br />
Repeat the above procedure except step 3:<br />
Step 3. Enter command 97 with option 2, by<br />
pressing “ 972 ”.<br />
<br />
Once this command is executed, SMS<br />
P-Word is re<strong>se</strong>t to PROG, SMS<br />
Keyword is re<strong>se</strong>t to SET, and SMS<br />
Header is re<strong>se</strong>t to ALARM<br />
UNIALERT.<br />
20
4.2. Event Code<br />
• 101 - Emergency<br />
Dual-Key 7+9<br />
• 110 - Fire<br />
Dual-Key 4+6<br />
SD<br />
• 120 - Panic<br />
When the of the Remote Controller is<br />
pres<strong>se</strong>d.<br />
Dual-Key 1 +3<br />
PB / WTR<br />
• 130 - Burglary<br />
When any one of the following devices<br />
is triggered:<br />
‣ The <strong>UniAlert</strong><br />
‣ Wired Terminal<br />
‣ IR / DC(Entry) / EIR<br />
• 137 - Burglary Tamper<br />
When the Tamper Switch on the Min<br />
<strong>GSM</strong> l is triggered.<br />
• 154 - Water Leakage<br />
When the Water Sensor connected to<br />
DC <strong>se</strong>t at Water (@W) is triggered.<br />
• 162 - CO Detector<br />
When the Carbon Monoxide detector<br />
is triggered.<br />
• 301 - AC Failure<br />
When the AC power fails for more<br />
than 30 <strong>se</strong>c.<br />
• 302 - Low battery<br />
When the battery voltage of the<br />
<strong>UniAlert</strong> is low.<br />
• 383 - Sensor Tamper<br />
When the Tamper Switch on any one<br />
of the following devices is triggered .<br />
‣ KP<br />
‣ PIR/EIR<br />
‣ DC<br />
• 384 - Sensor Low battery<br />
When the battery voltage of any one<br />
of the following devices is low.<br />
‣ RC/WTR/NS/PB<br />
‣ KP<br />
‣ DC<br />
‣ PIR/EIR<br />
‣ SD/CO<br />
‣ WS<br />
‣ BX/SR<br />
• 401 - Latch On<br />
When <strong>UniAlert</strong> Pin Code Latch is <strong>se</strong>t<br />
as On, and when enters Arm mode,<br />
event code 3401 will be <strong>se</strong>nt.<br />
• 406 - Panel Alarm Cancel<br />
• 407- Remote Arm/Disarm<br />
• 465 - Device Alarm Cancel (SD/PB/WTR)<br />
<br />
<br />
When the alarm from Panic Button<br />
(PB) or Wrist Transmitter (WTR) is<br />
cancelled within 8 <strong>se</strong>conds<br />
When an alarm is triggered by SD<br />
and the test button on the SD is<br />
pres<strong>se</strong>d<br />
21
DECLARATION OF<br />
CONFORMITY<br />
Hereby <strong>Electia</strong> AB declares that the <strong>UniAlert</strong><br />
<strong>GSM</strong> is in compliance with the es<strong>se</strong>ntial<br />
requirements and other relevant provisions of<br />
directive 1999/5/EC and RoHs 2002/95/EC.<br />
Härmed intygar <strong>Electia</strong> AB att <strong>UniAlert</strong> <strong>GSM</strong><br />
står i överensstämmel<strong>se</strong> med de vä<strong>se</strong>ntliga<br />
egenskapskrav och övriga relevanta<br />
bestämmel<strong>se</strong>r som framgår av direktiv<br />
1999/5/EG och RoHs 2002/95/EG.<br />
Peder Ljungstedt<br />
Produktansvarig<br />
<strong>Electia</strong> AB<br />
CE 0678<br />
At the end of its life, tho<strong>se</strong> products should<br />
NOT be dispo<strong>se</strong>d of in hou<strong>se</strong>hold rubbish.<br />
Seek the advice of your local authority on<br />
correct, environmentally friendly disposal.<br />
Batteries<br />
Do not dispo<strong>se</strong> of u<strong>se</strong>d batteries in the<br />
hou<strong>se</strong>hold rubbish! They should be deposited<br />
at a collection point for u<strong>se</strong>d batteries.<br />