09.07.2015 Views

Moulded Case Current Transformers - Crompton Western Canada Inc.

Moulded Case Current Transformers - Crompton Western Canada Inc.

Moulded Case Current Transformers - Crompton Western Canada Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Moulded</strong> <strong>Case</strong> <strong>Current</strong> <strong>Transformers</strong>802 Series Instrument <strong>Transformers</strong>Model 802-943 * * Model 802-940 * *SpecificationsApplication:Frequency:Installation Class:Dimensions (inches)Generally for Ammeter useonly50-400 Hz0.6 KV. BIL. 10 KV. full wave• Manufactured to meet the requirements ofUL 1244 and revisions• Flexible leads are UL 1015 105°C CSAapproved, #16 AWG, 24" long• Non-standard lengh to be specifed• Terminals are brass studs No. 8-32 UNCwith one flat washer, lockwasher andregular nut• UL Recognized• ABS ApprovedOrdering InformationCatalogue <strong>Current</strong> Accuracy Burden WeightNumber Ratio 60 Hz VA 60 Hz lbs* * U-NTLS 50:5 2.0 0.40* * U-NWLS 60:5 2.0 0.41* * U-PBLS 75:5 2.0 0.42* * U-PDLS 80:5 2.0 0.43* * U-PKLS 100:5 2.0 0.43* * U-PQLS 120:5 + 1% 2.5 0.44* * U-PSLS 125:5 + 1% 2.5 0.44* * U-PZLS 150:5 + 1% 4.0 0.45* * U-RLLS 200:5 + 1% 5.0 0.48* * U-RSLS 250:5 + 1% 7.5 0.51* * U-RXLS 300:5 + 1% 10.0 0.54Other ratios available on request.* * NOTE: When ordering, prefix Cat. No with model designation required. i.e. 802-943U-NTLS or 802-940U-NTLS<strong>Transformers</strong>Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002


<strong>Moulded</strong> <strong>Case</strong> <strong>Current</strong> <strong>Transformers</strong>805 Series Instrument <strong>Transformers</strong>Model 805-941 * * Model 805-940 * * Model 805-943 * *SpecificationsApplication:Frequency:Installation Class:With Ammeters,Wattmeters, Relays andcross current compensation50-400 HzDimensions (inches)0.6 KV. BIL. 10 KV. full wave• Manufactured to meet the requirements ofUL 1244 and revisions• Flexible leads are UL 1015 105°C CSAapproved, #16 AWG, 24" long• Non-standard lengh to be specifed• Terminals are brass studs No. 8-32 UNCwith one flat washer, lockwasher andregular nut• UL Recognized• ABS ApprovedOrdering InformationCatalogue <strong>Current</strong> Accuracy Burden WeightNumber Ratio 60 Hz VA 60 Hz lbs* * U-NTLS 50:5 0.97* * U-PBLS 75:5 0.97* * U-PKLS 100:5 0.97* * U-PQLS 120:5 0.97* * U-PSLS 125:5 0.97* * U-PZLS 150:5 + 1% 5.0 0.98* * U-RLLS 200:5 + 1% 5.0 1.01* * U-RSLS 250:5 + 1% 12.5 1.04* * U-RXLS 300:5 + 1% 12.5 1.07* * U-SCLS 400:5 + 1% 12.5 1.12* * U-SFLS 500:5 + 1% 25.0 1.12* * U-SJLS 600:5 + 1% 25.0 1.09* * U-SMLS 750:5 + 1% 25.0 0.95* * U-SNLS 800:5 + 1% 30.0 0.96* * U-SSLS 1000:5 + 1% 35.0 1.04* * U-SULS 1200:5 + 1% 40.0 1.08Other ratios available on request. Ordering mounting bracket kit separately option code MH. ie: 806-941U TCLS MH* * NOTE: When ordering, prefix Cat. No with model designation required. i.e. 805-940U-NTLS or 805-941U-NTLSor 805-943U-NTLS<strong>Transformers</strong>Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002


<strong>Moulded</strong> <strong>Case</strong> <strong>Current</strong> <strong>Transformers</strong>806 Series Instrument <strong>Transformers</strong>Model 806-941 * * Model 806-940 * * Model 806-943 * *SpecificationsApplication:Frequency:Installation Class:With Ammeters, Wattmeters,Relays and cross currentcompensation50-400 HzDimensions (inches)0.6 KV. BIL. 10 KV. full wave• Manufactured to meet the requirementsof UL 1244 and revisions• Flexible leads are UL 1015 105°C CSAapproved, #16 AWG, 24" long• Non-standard lengh to be specifed• Terminals are brass studs No. 8-32 UNCwith one flat washer, lockwasher andregular nut• UL Recognized• ABS ApprovedOrdering InformationCatalogue <strong>Current</strong> Accuracy Burden WeightNumber Ratio 60 Hz VA 60 Hz lbs* * U-PKLS 100:5 + 2% 2.0 1.14* * U-PZLS 150:5 + 1% 5.0 1.17* * U-RLLS 200:5 + 1% 5.0 1.20* * U-RSLS 250:5 + 1% 7.5 1.23* * U-RXLS 300:5 + 1% 12.5 1.26* * U-SCLS 400:5 + 1% 15.0 1.32* * U-SFLS 500:5 + 1% 25.0 1.38* * U-SJLS 600:5 + 1% 30.0 1.36* * U-SMLS 750:5 + 1% 30.0 1.38* * U-SNLS 800:5 + 1% 35.5 1.08* * U-SSLS 1000:5 + 1% 35.0 1.13* * U-SULS 1200:5 + 1% 40.0 1.22* * U-TCLS 1500:5 + 1% 50.0 1.28Other ratios available on request. Ordering mounting bracket kit separately option code MH. ie: 806-941U TCLS MH* * NOTE: When ordering, prefix Cat. No with model designation required. i.e. 806-940U-PKLS or806-941U-PKLS or 806-943U-PKLS<strong>Transformers</strong>Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002


<strong>Moulded</strong> <strong>Case</strong> <strong>Current</strong> <strong>Transformers</strong>807 Series Instrument <strong>Transformers</strong>Model 807-941 * * Model 807-940 * * Model 807-943 * *SpecificationsApplication:Frequency:Installation Class:Dimensions (inches)For Ammeters, Wattmeters,Relays and cross currentcompensation50-400 Hz0.6 KV. BIL. 10 KV. fullwave• Manufactured to meet the requirements ofUL 1244 and revisions• Flexible leads are UL 1015 105°CCSAapproved, #16 AWG, 24" long• Non-standard lengh to be specifed• Terminals are brass studs No. 8-32 UNCwith one flat washer, lockwasher andregular nut• UL Recognized• ABS ApprovedOrdering InformationCatalogue <strong>Current</strong> Accuracy Burden WeightNumber Ratio 60 Hz VA 60 Hz lbs* * U-PKLS 100:5 + 2% 2.5 1.29* * U-PZLS 150:5 + 1% 5.0 1.32* * U-RLLS 200:5 + 1% 5.0 1.35* * U-RSLS 250:5 + 1% 5.0 1.38* * U-RXLS 300:5 + 1% 12.5 1.41* * U-SCLS 400:5 + 1% 15.0 1.47* * U-SFLS 500:5 + 1% 25.0 1.53* * U-SJLS 600:5 + 1% 30.0 1.59* * U-SMLS 750:5 + 1% 30.0 1.60* * U-SNLS 800:5 + 1% 35.0 1.61* * U-SSLS 1000:5 + 1% 35.0 1.29* * U-SULS 1200:5 + 1% 40.0 1.38* * U-TCLS 1500:5 + 1% 50.0 1.50* * U-TELS 1600:5 + 1% 50.0 1.54Other ratios available on request. Ordering mounting bracket kit separately option code MH. ie: 807-941U-TELS-MH* * NOTE: When ordering, prefix Cat. No with model designation required. i.e. 807-940U-PKLS or807-941U-PKLS or 807-943U-PKLS<strong>Transformers</strong>Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002


<strong>Moulded</strong> <strong>Case</strong> <strong>Current</strong> <strong>Transformers</strong>808 Series Instrument <strong>Transformers</strong>SpecificationsModel 808-940 * * Model 808-941 * *Application:Frequency:Installation Class:Rating Factor:For relaying and metering50-400 Hz ANSI classesrelate to 60 Hz0.6 KV. BIL. 10 KV.1.33 at 30°C ambient and1.0 at 55°C ambientBurdens:ANSI 0.9 power factory meter burdens• Manufactured to meet the requirementsof UL 1244 and revisions• Flexible leads are UL 1015 105°C CSAapproved, #16 AWG, 24" long• Non-standard lengh to be specifed• Terminals are brass studs No. 8-32 UNCwith one flat washer, lockwasher andregular nut• UL Recognized• ABS ApprovedDimensions (inches)Ordering InformationCatalogue <strong>Current</strong> ANSI metering class at 60Hz VA for WeightNumber Ratio B0.1 B0.2 B0.5 B0.9 B1.8 1% Class lbs* * U-RLLS 200:5 1.2 1.2 - - - 5.0 2.19* * U-RSLS 250:5 0.6 1.2 2.4 - - 7.5 2.23* * U-RXLS 300:5 0.6 0.6 1.2 2.4 - 15.0 2.26* * U-SCLS 400:5 0.3 0.6 1.2 1.2 - 25.0 2.32* * U-SFLS 500:5 0.3 0.3 0.6 1.2 2.4 35.0 2.40* * U-SJLS 600:5 0.3 0.3 0.6 1.2 1.2 50.0 2.95* * U-SMLS 750:5 0.3 0.3 0.3 0.6 1.2 50.0 2.95* * U-SNLS 800:5 0.3 0.3 0.3 0.6 1.2 60.0 2.63* * U-SSLS 1000:5 0.3 0.3 0.3 0.6 0.6 75.0 2.07* * U-SULS 1200:5 0.3 0.3 0.3 0.3 0.6 75.0 2.19* * U-TCLS 1500:5 0.3 0.3 0.3 0.3 0.6 90.0 2.41* * U-TELS 1600:5 0.3 0.3 0.3 0.3 0.3 100.0 2.61* * U-TMLS 2000:5 0.3 0.3 0.3 0.3 0.3 120.0 2.21* * U-TULS 2500:5 0.3 0.3 0.3 0.3 0.3 130.0 2.50Other ratios available on request. Ordering mounting bracket kit separately option code MH. ie: 808-940U-TULS-MH* * NOTE: When ordering, prefix Cat. No with model designation required. i.e. 808-940U-PLLS or 808-941U-PLLS<strong>Transformers</strong>Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!