<strong>PRG</strong> <strong>Series</strong> <strong>400</strong> <br />
<strong>400</strong> <strong>Amp</strong> <strong>Disconnect</strong><br />
PROTECTION WHERE YOU NEED IT<br />
The <strong>PRG</strong> <strong>Series</strong> <strong>400</strong> <strong>400</strong> <strong>Amp</strong> <strong>Disconnect</strong> provides superior protection<br />
for high current AC power distribution systems used to support<br />
live entertainment productions. The <strong>Series</strong> <strong>400</strong> <strong>Disconnect</strong> is<br />
designed with rugged applications in mind, offering durability, portability,<br />
and safety protection, along with extensive power monitoring<br />
and convenience features.<br />
APPLICATION<br />
A <strong>Disconnect</strong> unit is required when 5-wire, 4/0 AWG feeder cables,<br />
greater than 10 feet in length, are connected between a house service<br />
of greater than <strong>400</strong> <strong>Amp</strong>s per phase and a portable power distribution<br />
system. The <strong>Disconnect</strong> will interrupt the 3-phase current<br />
flow under fault conditions, preventing dangerous overloads of the<br />
feeder cables. The <strong>Series</strong> <strong>400</strong> <strong>Disconnect</strong> may be used with the<br />
<strong>PRG</strong> <strong>Series</strong> <strong>400</strong> Power and Data Distribution System, other power<br />
distribution systems, or with portable power sources (generators) as<br />
long as its ratings are not exceeded and an adequate Earth ground<br />
has been established.<br />
CONNECT AND PROTECT<br />
Six high current connections are provided for input power, while<br />
twelve connections provide two complete sets of output power.<br />
Double Neutral connectors handle excessive neutral currents generated<br />
by low power factor loads, such as dimmers, to fully protect<br />
the system. Power monitoring features include seven digital LED<br />
meters which provide easily-readable 3-digit values, three voltmeters<br />
to measure the phase voltages present at the input - providing assurance<br />
that the supply voltage is correct before the Main Breaker is<br />
switched On - and four current meters which monitor each phase<br />
and the neutral circuit. In addition, neon indicators are provided to<br />
show when the feed cable is energized.<br />
ABOVE AND BEYOND<br />
Solid copper bus bars are used exclusively in all high-current circuitry<br />
to reduce losses and internal heating. This reduces the number of<br />
connections and eliminates high-current crimps. All Cam-Lok connectors<br />
are solidly bolted and locked to the bus bars, ensuring a long<br />
lasting, low resistance joint and maintenance-free life. To complete<br />
the package, the <strong>Series</strong> <strong>400</strong> <strong>Disconnect</strong> offers color coded, insulated<br />
test points for metering output voltage and local convenience<br />
outlets including 120V Edison, 208V Neutrik® PowerCon®, 208V<br />
L6-20R, and 120V/208V L21-30R styles.<br />
Features<br />
• Six Cam-Lok <strong>Series</strong> E1016 high current connections<br />
for input power.<br />
• Two sets of six Cam-Lok <strong>Series</strong> E1016 high current<br />
connectors for output power.<br />
• Double Neutral connectors to handle excessive<br />
neutral currents generated by low power factor<br />
loads such as dimmers.<br />
• Seven digital LED meters to monitor power<br />
flow, easily readable in direct sunlight.<br />
• Three voltmeters to measure phase voltages,<br />
ensuring that supply voltage is correct before<br />
the Main Breaker is switched On.<br />
• Four current meters to measure current flowing<br />
in each phase and in the neutral circuit.<br />
• Adjustable control for setting inrush limit.<br />
• Five color coded, insulated test points for<br />
metering output voltages.<br />
• Local convenience outlets for temporary connection<br />
of loads during early stages of set up.<br />
• Solid copper rigid bus bars and two thermostatically<br />
controlled cooling fans allow operation at<br />
100% of Rated current.<br />
• Suitable for use in U.S. and Canada, or in any<br />
locality with a 5-wire, 120/208V power grid.<br />
• Compact, rugged rolling rack design.<br />
<strong>One</strong> <strong>Source</strong>. <strong>Unlimited</strong> Resources.<br />
TM
<strong>Series</strong> <strong>400</strong> <strong>400</strong> <strong>Amp</strong> <strong>Disconnect</strong> Specifications<br />
The <strong>PRG</strong> <strong>Series</strong> <strong>400</strong> <strong>400</strong> <strong>Amp</strong> <strong>Disconnect</strong> shall be mounted in a Rolling Rack with two removable<br />
covers exposing the connector and control panels of the unit. Two locking casters shall keep the<br />
unit in place when connected.<br />
Solid copper bus bars shall be used in all high - current circuitry, reducing losses and internal heating.<br />
Two thermostatically controlled cooling fans shall be mounted within the enclosure and shall turn on<br />
when internal bus bar temperatures reach 55°C. Replaceable metal air filters shall cover fan inlets.<br />
Six Cam-Lok <strong>Series</strong> E1016 high current connections shall be provided for input power. Double<br />
Neutral connectors shall handle excessive neutral currents generated by low power factor loads.<br />
Neon lamps shall indicate when the cable feeding the <strong>Disconnect</strong> is energized. Twelve Cam-Lok<br />
<strong>Series</strong> E1016 high-current connectors shall be provided for output power. Safety covers shall be<br />
provided for all outputs.<br />
A thermal-magnetic Main Breaker shall protect circuit wiring so that long term operation at currents<br />
in excess of rated will cause it to trip, while magnetic elements respond quickly to overloads resulting<br />
from fault current surges. The Main Breaker shall tolerate momentary overcurrent conditions caused<br />
by inrush currents to prevent nuisance tripping when such loads are energized with full line voltage.<br />
The inrush limit shall be adjustable from 2000 to <strong>400</strong>0 <strong>Amp</strong>s by a slider control.<br />
A green LED Pilot Light shall indicate when the Main Breaker is ON. Operation of the LED may be<br />
checked when the Main Breaker is OFF by pushing in on the lens cap causing the LED to light. Seven<br />
digital LED meters shall monitor the power flowing through the <strong>Disconnect</strong>. Three voltmeters shall<br />
measure phase voltages present at the input to the Main Breaker. A rocker switch shall allow connection<br />
of the meters between the three phases (Ø-Ø) or between each phase and neutral (Ø-N).<br />
Four current meters shall measure the current flowing in each phase and in the neutral circuit. The<br />
current meters shall be isolated from the AC line by current transformers. The meters shall display<br />
a full-wave averaging, RMS calibrated value.<br />
Five color coded, insulated test points shall be provided for metering the output voltages after the<br />
Main Breaker. Local convenience outlets shall provide protected branch circuits: <strong>One</strong> 120V, 15 <strong>Amp</strong><br />
single phase circuit serving two Edison outlets; <strong>One</strong> 208V, 15 <strong>Amp</strong> single phase circuit serving two<br />
Neutrik® PowerCon® outlets; <strong>One</strong> 208V, 20 <strong>Amp</strong> single phase circuit serving one NEMA L6-20R<br />
outlet; and one 120V/208V, 30 <strong>Amp</strong> 3-phase, 5-wire circuit serving two NEMA L21-30R outlets.<br />
The <strong>Series</strong> <strong>400</strong> <strong>Disconnect</strong> shall be approved for use in the U.S. and Canada, or in any locality with<br />
a 5-wire, 120/208V power grid. The unit is also suitable for use with portable power sources (generators)<br />
as long as its ratings are not exceeded and an adequate Earth ground has been established.<br />
The unit shall conform to UL Standard 1640, be certified to Canadian Standard CAN/CSA STD C22.2<br />
No. 29, and shall carry the Intertek ETL safety mark. The unit shall be used in dry locations only and<br />
may be operated with the front rack cover in place, if desired.<br />
Ordering Information<br />
20.9680.0200 <strong>Series</strong> <strong>400</strong> <strong>400</strong> <strong>Amp</strong> <strong>Disconnect</strong><br />
XØ VOLTS YØ VOLTS ZØ VOLTS<br />
MAIN<br />
BR EAKER<br />
ON<br />
PUSH<br />
TO<br />
TES T<br />
SWITCH TO OFF<br />
POSITION TO<br />
RESET BREAKER<br />
INPUT VOLTAGES<br />
<strong>400</strong> AMP<br />
MAIN BREAKER<br />
ON<br />
Type 1Enclosure<br />
For use in DryLocations<br />
50 C MaxAmbient<br />
For Use in Areas Not Readily Accessible bythe General Public<br />
FOR USE BY QUALIFIED PERSONNEL ONLY<br />
WARNING - Risk of ElectricShock.<br />
OFF<br />
2000A 3000A <strong>400</strong>0A<br />
INRUSH LIMIT<br />
SETTING<br />
ARC MIXE D T U NGSTEN<br />
L OADS LOADS L OADS<br />
Conforms to:<br />
ProductionResourceGroup<br />
UL STD 1640<br />
8617AmbassadorRow<br />
Suite 120<br />
Certified to:<br />
Dallas, TX 75247<br />
CAN/CSASTDC22.2<br />
Made inUSA<br />
No.29<br />
XXXXX<br />
S-<strong>400</strong><br />
<strong>400</strong> AMP DISCONNECT<br />
MODEL 23-9680-0200<br />
Ø -Ø<br />
Ø -N<br />
600A MAX<br />
NEUT AMPS<br />
120/208V<br />
3ØY/30 A<br />
Production Resource Group<br />
XØ AMPS<br />
XØ<br />
GROUND<br />
FOR BRANCH CIRCUIT USE ONLY<br />
120V / 15A 208V / 15A 208V / 20A<br />
120/208V<br />
3ØY/30 A<br />
<strong>400</strong>A MAX<br />
YØ AMPS<br />
YØ<br />
NEUTRAL<br />
120/208V<br />
3ØY/30 A<br />
ZØ AMPS<br />
ZØ<br />
OUTPUT<br />
VOLTAGES<br />
TEST POINT<br />
FUSES<br />
1A / 250V<br />
AGC1<br />
RATINGS and AMPACITY<br />
Voltage Rating: 120/208V 3-phase wye with Neutral and<br />
Ground<br />
Line Frequency: 50 - 60 Hz<br />
Current Rating, Phases: <strong>400</strong> <strong>Amp</strong>s per phase continuous<br />
Current Rating, Neutral: 600 <strong>Amp</strong>s continuous<br />
Current Rating, Ground: <strong>400</strong> <strong>Amp</strong>s<br />
Fault Current Interrupting Capacity: 42,000 <strong>Amp</strong>s<br />
Fault Current Interrupt Time: Circuit clears in less than<br />
one line cycle<br />
MAIN BREAKER<br />
Type: Thermal-Magnetic, Square D Model LAL36<strong>400</strong><br />
Number of Poles: 3<br />
Voltage Rating: 600V AC<br />
Current Rating: <strong>400</strong> <strong>Amp</strong>s<br />
Inrush Overload Limit: Adjustable from 2000A to <strong>400</strong>0A<br />
DIGITAL LED METERS (7)<br />
Update Rate: 2.5 samples/sec.<br />
Display: 3-digit reading<br />
INPUT VOLTMETERS (3)<br />
Accuracy: ± 1 Volt<br />
Input Range: 85 - 264 Volts AC<br />
Overload Protection: 300V AC<br />
OUTPUT AMMETERS (4)<br />
Phase Current Meters full scale reading: <strong>400</strong> <strong>Amp</strong>s<br />
Neutral Current Meter full scale reading: 600 <strong>Amp</strong>s<br />
Overcurrent Rating: 1.5X rated full scale reading<br />
Accuracy (sine wave): ±0.15% of full scale or ±6 counts<br />
ENVIRONMENTAL<br />
Operational Temperature Range: -20° C to +50° C<br />
Cooling: Two thermostatically controlled fans<br />
For Dry Locations Only<br />
DIMENSIONS and WEIGHT<br />
Unit in Rolling Rack: 22.5”(L) x 22.5”(W) x 30.5”(H)<br />
Stand-Alone Panel w/o Rack: 8.5”(D) x 19”(W) x 23.5”(H)<br />
Weight: 153 lbs. with Rack / 79 lbs. w/o Rack<br />
D W<br />
S-<strong>400</strong><br />
<strong>400</strong> AMP<br />
DISCONNECT<br />
INPUT CONNECTIONS<br />
MUST BE MADE<br />
IN THE FOLLOWI NG<br />
ORDER:<br />
1) CONNECT GROUND<br />
2) CONNECT NEUTRAL<br />
3) CONNECT PHASES<br />
DISCONNECT IN<br />
REVERSE ORDER<br />
GND<br />
GND<br />
GND<br />
120/208V 3Ø OUTPUTS <strong>400</strong>A PER Ø MAX<br />
NEUT<br />
NEUT<br />
NEUT XØ<br />
YØ<br />
YØ<br />
120/208V 3Ø INPUTS <strong>400</strong>A PER Ø MAX<br />
NEUT<br />
NEUT<br />
NEUT<br />
XØ<br />
X Ø YØ<br />
FRONT SIDE BACK<br />
Atlanta 404-214-4800 | Chicago 847-227-5171 | Dallas 214-630-1963 | Denver 303-341-4848<br />
Detroit 248-526-5290 | Las Vegas 702-942-4774 | Las Vegas / Henderson 702-294-4805<br />
Los Angeles 818-252-2600 | Mount Vernon 914-662-3540 | Nashville 615-834-3190 | New Windsor 845-567-5700<br />
New York 212-589-5<strong>400</strong> | North Bergen 201-758-<strong>400</strong>0 | Orlando 407-855-8060 | Toronto 905-270-9050<br />
<strong>PRG</strong> <strong>Series</strong> <strong>400</strong> and Virtuoso® are trademarks of Production Resource Group, LLC. Neutrik® and PowerCon® are registered trademarks of Neutrik AG.<br />
©2008 Production Resource Group, LLC. All Rights Reserved. Specifications are subject to change without notice. Version: August 2008<br />
XØ<br />
YØ<br />
ZØ<br />
ZØ<br />
ZØ<br />
ZØ<br />
H<br />
www.prg.com