IPA/CPA Series - Airpax - Sensata

IPA/CPA Series - Airpax - Sensata

IPA/CPA Series - Airpax - Sensata

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Example:<strong>IPA</strong>P -1 -1REC4 - 61- 10.0 - L - 01 - T1 2 3 4 5 6 7 8<strong>IPA</strong> <strong>Series</strong> (PCB Mount)3-0-1-1REC4Third DecisionConfigurations-1REG4-1RS4-1RSG4Switch only<strong>Series</strong><strong>Series</strong> with silver contactAuxiliary switch<strong>Series</strong> with gold contactAuxiliary switch<strong>Series</strong> with silver contactAlarm switch<strong>Series</strong> with gold contactAlarm switchNotes: 1. For switch type, eliminate 4th & 5th decision.2. Switch will be marked with Max. current & voltage.3. The alarm switch is located in the handle pole forsingle handle types and in pole 2 for units with ahandle per pole. The auxilliary switch may be locatedin any pole. However the standard location is in pole 2.4. Switch type with alarm switch must be multi-poleconnected to a pole equipped with either anovercurrent or overvoltage mechanism.(Consult factory for further information.)4 Fourth DecisionFrequency & DelaySW Switch only56A-L-R-S-Fifth DecisionRated CurrentUse three numbers to specify requiredvalue within ranges described below.Rating0.50 to 30.0*Notes: 1. On multi-pole units, the poles are numbered left toright when viewed from terminal end.2. *15 amps maximum at 400HzSixth Decision (Optional)Mounting & Terminal TypeMetric M3 mounting inserts andif screw terminals M4.PC board mounting plate &terminals, 90 facing leftPC board mounting plate &terminals, 90 facing rightPC board terminals, rear facingwith front panel insert mount.Note: Right and Left determined with breaker viewed fromthe rear, in normal vertical mounted position. (see pages 70 & 71)-40400Hz instant trip-41-42-400-50400Hz short delay400Hz long delay400Hz motor startDC instant trip*701Seventh DecisionHandle ColorBlack with I/O markings-51DC short delay*-52-500-60-61-62-600DC long delay*DC motor start50/60Hz instant trip50/60Hz short delay50/60Hz long delay50/60Hz motor start8TCEighth Decision (Optional)Agency ApprovalTÜV*CCCNotes: 1. *25 amperes max rated current for TÜV approval.2. CCC Approval is pending.Note: For addition of inertial delay, add an “F” to anydelay numeral. (Example: 62F)*<strong>CPA</strong> types are only available with DC ratings.<strong>IPA</strong> <strong>Series</strong> - Decision Tables 96

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!