U II BOP Part NumbersItemNumberDescriptionQty.SingleQty.Double18-3/4”10,000 psi18-3/4”15,000 psi34 O-Ring, Ram Change to Piston Body 4 8 702645-34-31 702640-34-3135 O-Ring, Ram Change Cylinder to Body 4 8 702645-44-21 702640-44-2136 O-Ring, Ram Change Cylinder to Int. Flange 4 8 702645-44-01 702640-44-0137 Bearing Gland, Intermediate Flange 8 16 615727-01 615727-0138 Seal Ring, Ram Change Piston Rod to Int. Flg. 4 8 707233 70723339 Connector, Tubing 2 4 707159 70715940 Retainer Ring, Lip Seal Tailrod 2 4 614672-04 614672-0441 Gland, Bleeder 6 12 017454-08 017454-0842 Plug, Bleeder 6 12 017454-09 017454-0943 Lifting Eye 2 2 011849 01184944 Seal Ring, Ram Change Piston Head 4 8 707231 70723145 Wear Ring, Operating Piston 2 4 049223-16 049223-1845 Wear Ring, Operating Piston 2 4 --- 049233-19+46 Lip Seal, Operating Piston 2 4 710545 71054646 Lip Seal, Operating Piston 2 4 --- 710851+47 O-Ring * ** 2708812-02 702645-47-1148 Cylinder, Operating 2 -- 030274-15 ---48 Cylinder, Operating 2 -- --- 644613-01+49 Bearing Retainer Ring, Seal 4 8 614348-10 614348-1050 Plastic Packing 10 20 007650-25 007650-2551 Ring, Seal Operating Piston 2 4 710640 71064052 Ring, Backup 2 4 610108-28 610108-2853 Check Valve, Weep Hole -- -- 709493 70949354 Wedgelock w/Pressure Balance Chamber (RH) 2 4 615402-01 615402-0154 Wedgelock w/Pressure Balance Chamber (LH) 2 4 615402-02 615402-0255 O-Ring (Not Shown) 2 4 --- 702645-46-91+* 4 required for 18-3/4” 10,000 psi BOP; 2 required for 18-3/4” 15,000 psi BOP.** 8 required for 18-3/4” 10,000 psi BOP; 4 required for 18-3/4” 15,000 psi BOP.+ Alternate parts for 18-3/4” 15,000 psi BOP assembly with operating cylinder.TC1001 66 © <strong>2002</strong> Cooper Cameron, Cameron Division
U II BOP Pipe RamsPipe rams are available for use in Cameron U IIBOPs to fit all commonly used sizes of tubing,drill pipe, drill collar or casing within theranges in the chart on this page. Cameron piperams include the following features:• Cameron pipe rams areself-feeding and incorporate alarge reservoir of packer rubberto ensure a long-lasting sealunder all conditions.• Ram packers lock into place andare not dislodged by well flow.• Cameron U II pipe rams aresuitable for H 2 S service perNACE MR-01-75.• CAMRAM TM top seals arestandard for all U II BOP pipe rams.• CAMRAM 350 TM packers and top seals are available for high temperature service and forservice in which concentrations of H 2 S are expected.U II BOP Pipe Ram Part Numbers18-3/4” 10,000 and 15,000 psi U IIPipe SizeTop Seal: 645282-01-00-01Assembly Ram PackerBlind 644248-01 615407-01 644247-01-00-012.375” 644248-02 614770-01 644247-02-00-012.875” 644248-03 614770-02 644247-03-00-013.500” 644248-04 644742-01 644247-04-00-013.500” Aluminum 644248-05 614770-04 644247-05-00-014.000” 644248-06 614770-05 644247-064.500” 644248-07 644742-02 644247-074.500” Aluminum 644248-08 614770-07 644247-084.750” 644248-09 614770-08 644247-095.000” 644248-10 644742-03 644247-10-00-015.500” 6445248-11 614770-10 644247-11-00-015.875” 644248-23 614770-23 644247-23-00-016.000” 644248-12 614770-12 644247-12-00-016.625” 644248-13 614770-13 644247-137.000” 644248-14 614770-14 644247-147.625” 644248-15 614770-15 644247-15-00-018.625” 644248-16 614770-16 644247-16-00-019.000” 644248-17 614770-17 644247-17-00-019.625” 644248-18 614770-18 644247-18-00-0110.750” 644248-19 614770-19 644247-19-00-0113.375” 644248-21 614770-21 644247-21-00-01TC1001 67 © <strong>2002</strong> Cooper Cameron, Cameron Division
- Page 8 and 9:
Cameron Elastomer Technology employ
- Page 12 and 13:
U BOP Hydraulic Control SystemThe U
- Page 17 and 18: 7-1/16” 3000 - 11” 10,000 psi W
- Page 19 and 20: 11” 15,000 - 16-3/4” 5000 psi W
- Page 21 and 22: 16-3/4” 10,000 - 26-3/4” 3000 p
- Page 23 and 24: Kit Part NumbersBOP Size (in.) Pres
- Page 25 and 26: Tandem Boosters for U BOPsA BOP equ
- Page 27 and 28: UM BOPsThe Cameron UM BOP is a ligh
- Page 29 and 30: UM BOP Operating Data and Fluid Req
- Page 31 and 32: UM BOP Specifications and Dimension
- Page 33 and 34: UM BOP Specifications and Dimension
- Page 35 and 36: 7-1/16” UM BOP Part NumbersItem N
- Page 37 and 38: 11” UM BOP Part NumbersItem No. D
- Page 39 and 40: 13-5/8” UM BOP Part NumbersItem N
- Page 41 and 42: Tandem Boosters for UM BOPsA BOP eq
- Page 43 and 44: U, UL and UM BOP Pipe RamsPipe rams
- Page 45 and 46: Part Numbers for U, UL & UM BOP Pip
- Page 47 and 48: Hang-Off WeightsHang-off weights ar
- Page 49 and 50: H 2 S Shearing Blind RamU, UL and U
- Page 51 and 52: ISR Shearing Blind RamInterlocking
- Page 53 and 54: U, UL and UM BOP Variable Bore Rams
- Page 55 and 56: Inserted PackersThe Cameron Inserte
- Page 57 and 58: Hydraulic Bonnet Bolt SystemThe hyd
- Page 59 and 60: Bonnet Seal Carriers for U, UM and
- Page 61 and 62: UIIBOPThe Cameron U II BOP takes al
- Page 63 and 64: U II BOP DimensionsThe following de
- Page 65: U II BOP Part NumbersItemNumberDesc
- Page 69 and 70: U II BOP Shearing Blind RamsCameron
- Page 71 and 72: T BOPThe Cameron T blowout prevente
- Page 73 and 74: OPENPORTLOCKPORTCLOSEPORTRam Open;
- Page 75 and 76: 2006 Volvo S60Storing stations auto
- Page 78 and 79: 18-3/4” 15,000 psi WP T BOP Part
- Page 80 and 81: TC1001 80 © 2002 Cooper Cameron, C
- Page 82 and 83: TL BOP Heights and WeightsBOPSize a
- Page 84 and 85: Reference Page 86RAM Lock3 2 5 6 7
- Page 86 and 87: 39284439513935392534731645333031342
- Page 88 and 89: 39284439513935392534731645333031342
- Page 90 and 91: 15161317101215262521302954976181919
- Page 92 and 93: 151610191911171813315171215SD 03462
- Page 94 and 95: 1944 8 7 81534 35 363131927 458 7 8
- Page 96 and 97: 91031ST-Lock Assembly Components271
- Page 98 and 99: 484650 49 47“Lock” Port533940
- Page 100 and 101: 4640`A’413925`A’26Typ 8 Places2
- Page 102 and 103: TL BOP Super Shear BonnetsA TL BOP
- Page 104 and 105: T and TL BOP Pipe RamsPipe rams are
- Page 106 and 107: T and TL BOP Pipe Ram Part Numbers
- Page 108 and 109: T and TL BOP DVS Shear RamsDouble V
- Page 111 and 112: C BOPThe Cameron C BOP was designed
- Page 113 and 114: C BOP DimensionsBOP Size andWorking
- Page 115 and 116: 7-1/16” 10,000 psi WP C BOP Part
- Page 117 and 118:
13247Sequencing ValveSubassembly Co
- Page 119 and 120:
C BOP Shearing CapabilityMaterial S
- Page 121 and 122:
TC1001 121 © 2002 Cooper Cameron,
- Page 123 and 124:
S/QRC and G-2 BOP RamsBOPDescriptio
- Page 125 and 126:
D and DL Annular Blowout Preventers
- Page 127 and 128:
D and DL Annular BOP ComponentsItem
- Page 129 and 130:
7-1/16” 3000 - 20,000 psi WP D an
- Page 131 and 132:
11” 3000 - 10,000 psi WP D and DL
- Page 133 and 134:
13-5/8” 5000 - 16-3/4” 5000 psi
- Page 135 and 136:
18-3/4” 5000 - 21-1/4” 2000 psi
- Page 137 and 138:
DL Annular BOPReplacement Part Kits
- Page 139 and 140:
Clamp Connections (1-13/16” 10,00
- Page 141 and 142:
TC1001 141 © 2002 Cooper Cameron,