10.07.2015 Views

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

Driver Manual FS-8704-14 EtherNet/IP - FieldServer Technologies

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>FS</strong>-<strong>8704</strong>-<strong>14</strong> <strong>EtherNet</strong>/<strong>IP</strong> <strong>Manual</strong> Page 7 of 315 CONFIGURING THE FIELDSERVER AS AN ETHERNET/<strong>IP</strong> CLIENTFor a detailed discussion on <strong>FieldServer</strong> configuration, please refer to the <strong>FieldServer</strong> Configuration <strong>Manual</strong>. Theinformation that follows describes how to expand upon the factory defaults provided in the configuration filesincluded with the <strong>FieldServer</strong>.This section documents and describes the parameters necessary for configuring the <strong>FieldServer</strong> to communicatewith an <strong>EtherNet</strong>/<strong>IP</strong> Server.The configuration file tells the <strong>FieldServer</strong> about its interfaces, and the routing of data required. In order to enablethe <strong>FieldServer</strong> for <strong>EtherNet</strong>/<strong>IP</strong> communications, the driver independent <strong>FieldServer</strong> buffers need to be declared inthe “Data Arrays” section, the destination device addresses need to be declared in the “Client Side Nodes” section,and the data required from the servers needs to be mapped in the “Client Side Map Descriptors” section. Detailson how to do this can be found below.Note that in the tables, * indicates an optional parameter, with the bold legal value being the default.5.1 Client Side Connection ParametersSection TitleAdapterColumn Title Function Legal ValuesAdapter Adapter Name N1, N2 2Protocol Specify protocol used <strong>EtherNet</strong>/<strong>IP</strong>Example// Client Side ConnectionsAdaptersAdapterN1, Protocol, <strong>EtherNet</strong>/<strong>IP</strong>5.2 Client Side Node Parameters 3Section TitleNodesColumn Title Function Legal ValuesNode_Name Provide name for node Up to 32 alphanumeric characters<strong>IP</strong>_Address Address of Server Any valid address on subnetProtocol Specify protocol used <strong>EtherNet</strong>/<strong>IP</strong>Adapter Specify port Adapter used N1, N2 2Plc_Type*Specify the type of remote PLC. Onlyrequired for PCCC ServicesMicroLogix, SLC5, PLC52 Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction manual for details of the ports availableon specific hardware.3 Only one explicit connection is created per node. All explicit Map Descriptors attached to that node will use the same explicit connection.<strong>FieldServer</strong> <strong>Technologies</strong> 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.comTel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!