DIGISTAT OPTIMISEROPERATING CONTROLSDigistat Optimising ProgrammerThe Digistat Optimising Programmer has factory set programs for ON/OFF periods for central heatingwhich are described on the following pages.These factory installed settings can be used without any further programming.Clock SettingThe Digistat Optimising Programmer is fitted with a real-time clock, which is pre-set at the factory.You will not have to set the time.A special feature of this real-time clock is to automatically update the time during the summer/winter timechange removing the need to manually alter the clock.DaysTemperaturesee note+ or - buttons forsetting adjustmentDay indicatorFlame showswhen callingfor heatTimemodeindicatorHoliday, Manual,Auto, Day modeLeft hand button < movespointer to the left for selectionRight hand button > moves thepointer to the right, selects andaccepts changesClock modeNOTE: The temperature displayed is actual room temperature unless adjusting the + or - buttonwhen the set temperature is displayed. Once adjustment is complete and after a 5 seconddelay the display will return to the actual room temperature.General OperationWith the unit in Auto mode (the small arrow to bottom of screen will point to Auto) the temperature can bechanged for a short time by using the + or - buttons. Changing the temperature in this way will keep theProgrammer set to your new temperature until the next pre-programmed event (at which time it will revertto programmed temperature). The temperature you are setting will flash on the screen. Once temperatureis set, the unit will revert to showing the current temperature. The indicator will show on the screen if theheating is turned on.4OPER AT I NG & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DIGISTAT OPTIMISERPRE-PROGRAMMED SETTINGSPROGRAMMABLE SETTINGSADJUSTING TIMES & TEMPERATURESThe Digistat Optimising ProgrammerThis is a programmable thermostat 5-2 Day / 7Day product. 5–2 day allows you to set a programfor weekdays and a program for the weekend.Full 7-day functionality allows you to set a differentprogram for every day of the week.Each program type allows you to set 6 time andtemperature events.Pre-set Program 1The following default settings are pre-programmedfor your convenience:Monday - FridayEvent 1 2 3 4 5 6Time 06:30 08:30 12:00 14:00 16:30 22:30Temp. 20 16 16 16 21 7As shown, at 06:30 , the heating will come on toraise the temperature to 20°C. At 08:30, the temperatureset point is dropped from 20°C downto16°C, it stays at 16°C throughout the day, until16:30 when the temperature increases to 21°C.The temperature then drops down to a night-setbacktemperature of 7°C until 06:30 when thecycle repeats for the next day. (Monday to Friday)For changes to weekend setting see below.Saturday - SundayEvent 1 2 3 4 5 6Time 7:70 9:00 12:00 14:00 16:00 23:30Temp. 20 18 21 18 21 7As shown, at 07:00, the heating will come on toraise the temperature to 20°C. At 09:00, the temperatureset point is dropped from 20°C downto18°C, it stays at 18°C until 12:00 when theheating comes on to raise the temperature to21°C. The temperature stays at 21 C until 14:00when it drops down to 18°C.At 16:30 the heating comes on to raise the temperatureto 21°C where it stays until 23:00 whenthe temperature then drops down to a night-setbacktemperature of 7°C until 07:00 when thecycle repeats for the next day. (Saturday andSunday) or changes to weekday settings seeabove.Digistat Optimising Programmer -5-2 Day operation:1. With the productoperating as normalin Auto mode press> once then press +button until thedisplay is flashing asshows.2. Press > once, thedisplay will be asshown. The time willbe flashing, use + or- buttons to adjust1st time as required.3. Once time hasbeen set, press >and use + or - buttonto adjustrequired temperature(shown flashing).Press > to confirmand move to nexttime and temperatureperiods to beadjusted confirmchanges by pressing> button. (max 6periods).4. Once the lastweekday temperaturehas been setpress > once to confirmand allow adjustmentof the weekendprogram. Use + and– buttons and > buttonto set the 6 periodsfor the weekendprogram.5. Once the finaltemperature hasbeen set press > toconfirm. To exit press< or > until youreturn to auto modewith bottom arrowpointing at Auto.(* small 1 in lower half ofscreen shows time periodis being set e.g. 1=1stperiod, 2 = 2nd period etc)DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 5


PROGRAMMABLE SETTINGSADJUSTING TIMES & TEMPERATURESTo change temperature for a short period(Override):1. Press + or -buttons to adjust settemperature.Set temperatureshown flashingDigistat Optimising Programmer -7-Day operation:1. With the productoperating as normal inthe Auto mode pressonce and then pressthe + button until thedisplay is flashing andshows.2. After 5 secondswill start controllingat selected set pointbut displays actualroom temperature.Two chevronsindicates overridemode.2. Press the once, thedisplay will be asshown. Thetime will be flashing,use the + or - buttonsto adjust the 1st timeas required.3. To exit overridepress > once orwait until nextchange in thepre-set program.To set a constant room temperature(Manual mode):1. Press > once,the display showstemperatureflashing (eg. 20°C)3. Once time hasbeen set, press > anduse + or - buttons toadjust requiredtemperature.Repeat above steps 2-3 until the 6 periodshave been set forMonday(* small 1 in lower half of screenshows time period is being sete.g. 1=1st period, 2 = 2nd period etc)4. Once Monday hasbeen set, press once.Repeat steps 2-3 untilall 7 days of the weekhave been set.2. Press + or - buttonsto adjust thetemperature asrequired. The temperaturewill stopflashing after 5 secondsand start controllingat thistemperature.5. Once the final temperaturehas been setpress the to confirmsettings. To exit pressor until you return toauto mode with thebottom arrow pointingat Auto.3. Press > once, to return to auto mode.6OPER AT ING & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


PROGRAMMABLE SETTINGSADJUSTING TIMES & TEMPERATURESTo set holiday mode:1. Press < twice,the display showstime flashingTime periodsbetween 1 to23(Hr) hours and1 to 199(d) dayscan be set.To switch the thermostat OFF:Press the + and – simultaneously for 5 seconds untilthe OFF is displayed.The thermostat and heating system will now be OFFunless the temperature in the controlled space fallsbelow 7°C, the frost protection set point.Please note this does not affect the operation of thedomestic hot water where provided.To switch ON the thermostat, press any key to returnto auto mode.2. Press + or -buttons to adjustthe count downtime as required.Press > once toconfirm, the displaywill show temperatureflashing.3. Press + or -buttons to adjusttemperature andpress > to startholiday countdown time.Alternatively after10 seconds thetemperature willstop flashing andholiday countdown time will start.Display shows countdown time andambient roomtemperature.4. To exit theholiday modepress the < or >once, to return toauto.DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS7


DIGISTAT OPTIMISERUSER OPTIONSUser OptionsUser Options (shown in table below) can beaccessed from Auto or Man by pressing < and >simultaneously for 3 seconds.Once you haveaccessed the UserOptions Menu press> to scroll throughselectable options.The settings for eachoption can bechanged by pressing+ or - as required.Pressing > accepts the change and moves to thenext option.NOTE: To exit User Options press < and >simultaneously for 3 seconds.Alternatively, not pressingany buttons for 2minutes will cause theProgrammer to returnto Auto.This figure oppositeshows option “01 24”(24 hour clock).Only options that havebeen accepted bypressing > will be changed.Option Description of Option Min Max Default01 Change clock 12h/24h 12 24 2402 Change pre-set program 1 3 103 Change number of programevents per day04 Switch on/off daylight savingtime change2,4 or 6 6On Off On05 Adjust date and time Factory set06 Change temperature offset C -5 5 007 Restore pre-set program On Off Off08 Disable OFF function On Off On09 Access protection lock On Off OffOption 01 Change from 24hr to 12hr clock.Enter user options, select option 01 and use + and– keys to select desired option, 12 = 12hr and 24 =24hr. Press > to accept change.Option 02 Change to program 1, 2 or 3.Enter user options, select option 02 and use + and– keys to select desired program 1, 2 or 3.1 = program 1, 2 = program 2 and 3 = program 3.Press > to accept change.Preset programs 2 and 3 are shown below:Pre-set Program 2 (Home for lunch)Monday to FridayEvent 1 2 3 4 5 6Time 6:30 8:30 12:00 14:00 16:30 22:30Temperature 21 16 21 16 21 10At 06:30 the heating raises the temperature to 21°C.At 08:30, the temperature set point is dropped to16°C, until 12:00 when the heating raises thetemperature to 21°C. The temperature stays at 21°Cuntil 14:00 when it drops to 16°C. At 16:30 the heatingraises the temperature to 21°C where it staysuntil 22:30 when the temperature drops down to asetback temperature of 10°C until 06:30 when thecycle repeats the next day.Saturday to SundayEvent 1 2 3 4 5 6Time 7:00 9:00 12:00 14:00 16:30 23:00Temperature 21 18 21 18 21 16At 7:00, the heating raises the temperature to 21°C.At 9:00, the temperature set point is dropped to18°C, it stays at 18°C until12:00 when the heatingraises the temperature to 21°C.The temperature stays at 21°C until 14:00 when itdrops down to 18°C. At 16:30 the heating raises thetemperature to 21°C where it stays until 23:00 whenthe temperature drops down to a setback temperatureof 10°C until 07:00 when the cycle repeats thenext day.8OPER AT ING & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DIGISTAT OPTIMISERUSER OPTIONSPre-set Program 3 (Home Worker)Monday to FridayEvent 1 2 3 4 5 6Time 6:00 8:30 12:00 14:00 17:30 22:30Temperature 21 19 21 19 21 16As you can see, at 06:00, the heating will come on toraise the temperature to 21°C.At 08:30, the temperature set point is dropped to19°C, it stays at 19°C until 12:00 when the heatingcomes on to raise the temperature to 21°C. The temperaturestays at 21°C until 14:00 when it drops to19°C. At 17:30 the heating comes on to raise thetemperature to 21°C where it stays until 22:30 whenthe temperature drops down to a setback temperatureof 16°C until 06:00 when the cycle repeats thenext day.Saturday to SundayDate and time setting.The DT10RF Optimising Programmer comes with apre-set clock, which also automatically adjusts fordaylight saving time changes. It is activated automaticallyon 1st installation. There should be no need tochange these settings, however, should you wish to,it can be done in Option 05.Option 05 How to adjust date and time.Enter user options,select option 05To change the yearpress > onceEvent 1 2 3 4 5 6Time 7:00 9:00 12:00 14:00 16:30 22:00Temperature 21 18 21 18 21 16As you can see, at 7:00, the heating will come on toraise the temperature to 21°C.At 9:00, the temperature set point is dropped to18°C, it stays at 18°C until12:00 when the heatingcomes on to raise the temperature to 21°C. The temperaturestays at 21°C until 14:00 when it dropsdown to 18°C. At 16:30 the heating comes on toraise the temperature to 21°C where it stays until23:00 when the temperature drops down to a setbacktemperature of 16°C until 07:00 when the cyclerepeats the next day.Option 03 How to change the number of programevents per day.Enter user options, select option 03 and use + and –keys to select option. 2 = 2 time / temp events perday, 4 = 4 time / temp events per day and 6 = 6 time/ temp events per day. Press > to accept change.Option 04 How to switch on/off the automaticsummer / winter time change.Twice a year the actual time is automatically changedto keep it in line with the summer / winter timechange. Default setting is On.If you wish to disable / enable this feature enter useroptions, select option 04 and press – or + key to displayOff or On as desired. Press > to accept change.DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)To change the monthpress > againTo change the daypress > againTo change the timepress > againOnce you have selectedyour required display,to adjust press +or - and > to acceptchange.To select option 06press > until option06 display is shownOPER AT ING & INSTA L L AT IONINST RUCT IONS 9


DIGISTAT OPTIMISERUSER OPTIONSNOTE: Option 5 must be completed beforeattempting option 6Option 06 How to change temperature offset.The temperature displayed on the thermostat may notmatch that of other temperature measuring devices inthe controlled space, because of its location.The displayed temperature may be offset to bring it inline with other devices.To adjust the temperature, enter the user options,select option 06.The temperature may be offset by +/- 5 degrees bypressing the + and – keys. Press > to accept thedesired change.Option 07 How to restore the built in timetemperature programs.NOTE: Enabling this function will lose any userchanges to the preset programs.Enter user options, select option 07 and use + and –keys to select desired option. Off = current programsretained. On = restore factory program settings.Press > to select the desired change.The option 07 display automatically reverts back tooff.Option 08 How to disable the OFF function.To disable the OFF function, enter user options,select option 08 and use + or – keys to select Off.Press > to accept change.It is now not possible to switch the Digistat OFFusing the + and - keys as previously described.To enable the OFF function return to option 08 andselect ON. Press > to accept change.Option 09 How to lock the key pad -Access Protection Lock.The access protection lock allows you to lock theDigistat Optimiser so that it cannot have any adjustments.The default is OFF mode allowing you to adjust theDigistat.To Lock the Digistat settings enter the User OptionsMenu Option 09 and select On and press > toaccept.Once the User Options Menu is exited all buttons willbe locked.To switch off the Protection Lock enter the UserMenu and change to OFF. Press > to accept.Once the User Menu is exited all buttons will be freeto adjust.NOTE: To exit User Options press < and >simultaneously for 3 seconds.Special Note:The following only applies when the Intelligentdelayed start feature is enabled.Ask your installer for detailsWhen the delay period is operating indicated by theflame symbol flashing, pressing any button returnsthe DT10RF Programmer/Optimising Programmer toauto mode allowing normal button operation until thenext time/temperature event, when it will resume thedelay start mode or follows the Holiday, Manual,Override or Off modes as selected.Changes to the installer options and pre-set programmesmust be made with the flame symbol notflashingWhat is Intelligent delayed start.The Intelligent Delayed Start is an energy savingfeature which automatically reduces the warm uptime for the heating system.As the weather becomes milder, Intelligent Start willdelay the heating start times so that the fuel is notwasted bringing the room up to temperature earlierthan necessary.NOTE: See page 23 for further information and setup details.10OPER AT ING & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DT10RF RECEIVEROPERATING CONTROLSDT10RF Receiver ProgrammerThe Programmer has factory set programs forON/OFF periods for hot water pre-heat, which aredescribed on the following pages.These factory installed settings can be used withoutany further programming.This section also details how to program theDT10RF Receiver with new weekday and weekendtimes to suit your lifestyle requirements.How to set the clock, time and date, is also given,but should not require adjustment as these arefactory set.A holiday function is also provided, where the numberof days that you are away on holiday can be set.After that set period of time the boiler will revert tothe normal operating program.Mode indicatorModesHot water preheatON lightHot water preheatadvancebutton, whenpressed stayson until next offperiod.Hot water pre-heatselect button, movesthe pointer up anddown to select andaccept changesSetting clock, date,time, program andholiday function+/- changesON/OFF timesPress to accept eachprogram settingDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS11


DT10RF RECEIVEROPERATING CONTROLSHot Water:1. Press select button to choose off = constantly OFFtimed = up to 3 ON and 3 OFF time periods asprogramonce = ON from first ON until third OFF timeperiod as programon = constantly ON2. Press “advance” button:ON = hot water pre-heat light on(hot water pre-heat stays on untilnext off time period)OFF = hot water pre-heat light off(hot water pre-heat stays off untilnext on time period)NOTE: Advance has no effect with the constantlyon or off selected on the receiver.12OPER AT ING & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DT10RF RECEIVERPRE-PROGRAMMED SETTINGSNOTE: The ON/OFF periods pre-programmed forHot Water pre-heat are shown in thetable opposite.The factory installed settings can be usedwithout any further programming of thereceiver.The date and time are pre-programmedand should not require adjustment.If you need to restore the factory pre-setprogram times then:Press the + and - buttons together, for atleast 3 seconds, to restore the defaultprogram times.The default ON/OFF periods pre-programmedfor hot water pre-heat areshown in the table opposite.NOTE: Two ON/OFF periods can be usedinstead of three, by setting the secondON/OFF periods to 12:00 as shown inthe default program table.One ON/OFF period can be achieved by settingthe second and third ON/OFF periods to thesame time.See RECEIVER PROGRAMMABLE SETTINGSif changes are required to the clock time or preprogrammedsettings.DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 13


DT10RF RECEIVERPROGRAMMABLE SETTINGSSetting MON - FRI times1. Press set? until SET and PROG? are shownin the display.2. Press OK to select MON-FRI.3. Press OK to select ON time.NOTE: Speed up the display by holding downthe + or - buttons.4. Press + or - to change the ON time.5. Press set? to set the ON time and select theOFF time.6. Press + or - to change the OFF time7. Press set? to set the OFF time and select thenext ON time.Repeat operations 4 to 7 to set the second andthird ON/OFF times.NOTE: After pressing set? for the third hotwater pre-heat OFF time the displayshows SET MON ...see next page14OPER AT I NG & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DT10RF RECEIVERPROGRAMMABLE SETTINGSSetting individual weekday times:NOTE: If you do not require individual weekdaytimes, then press set? until SET SUN-SATare displayed and continue on the nextpage.If you do not wish to change the setting for the daydisplayed, then press set? until the first day youwant to change is displayed.1. Press OK to select weekday.2. Press OK to select first ON time.NOTE: Speed up the display by holding downthe + or - buttons.3. Press + or - to change the ON time.4. Press set? to set the ON time and select theOFF time.5. Press + or - to change the OFF time.6. Press set? to set the OFF time and select thenext ON time.Repeat operations 3 to 6 to set the second and thirdON/OFF times.NOTE: After pressing set? for the third OFF time,SET and the next weekday are displayedafter completing the steps above for FRI thedisplay shows SET SAT-SUN.see next page....DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 15


DT10RF RECEIVERPROGRAMMABLE SETTINGSSetting SAT - SUN times:1. Press OK to select weekend.NOTE: Speed up the display by holding downthe + or - buttons.2. Press + or - to change the ON time.3. Press set? to set the ON time and select theOFF time.4. Press + or - to change the OFF time.5. Press set? to set the OFF time and select thenext ON time.Repeat operations 2 to 5 to set the second and thirdON/OFF times.NOTE: After pressing set? for the third OFF time,SET SAT are displayed....If you do not require individual weekendtimes, then press SET until the normaldisplay is resumed.Setting individual weekend day times:NOTE: If you do not require individual weekendtimes, then press set? until the normal displayis shown.If you do not wish to change the setting for SAT,then press set? until the normal display is shown.1. Press OK to select the day displayedNOTE: Speed up the display by holding downthe + or - buttons.2. Press + or - to change the ON time.3. Press set? to set the ON time and select theOFF time.4. Press + or - to change the OFF time.5. Press set? to set the OFF time and select thenext ON time.Repeat operations 2 to 5 to set the second and thirdON/OFF times.Press set? to change SUN or until the displayreturns to normal mode.16OPER AT I NG & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DT10RF RECEIVERPROGRAMMABLE SETTINGSHoliday settings1. Press the set? button until SET and HDAY aredisplayed.2. Press OK, the display shows 00.3. Press + or - to set the number of days you requirethe system to be off.4. Press set? then HDAY is shown in the displayand no demand for heating will be made from the<strong>programmer</strong>. The <strong>programmer</strong> will return to normalafter the set number of days.To cancel the Holiday setting and return to normaloperation, press any button.NOTE: The <strong>programmer</strong> counts each pass throughmidnight as a day.For example, if you did not want heatingfrom Saturday morning until Tuesdaymorning, set for three days.DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 17


DT10RF RECEIVERPROGRAMMABLE SETTINGSSetting the clock and time1. Press the set? button until SET and CLOCK aredisplayed.2. Press OK.3. Press + to switch between 24hr and 12hr display4. Press set? to set the clock and the hours displayflashes.5. Press + or - to set the correct hour.NOTE: Speed up the display by holding downthe + or - buttons.6. Press the set? button to accept the correct hourand minutes display flashes.7. Press + or - to set the correct minutes.8. Press the set? button to accept the correctminutes. Now SET and DATE will be displayed.NOTE: If the day displayed is incorrect the dateneeds resetting. To change the date, refer toSETTING THE DATE on the next page.If you do not wish to change the date, pressset? to return to the normal display18OPER AT ING & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DT10 RF RECEIVERPROGRAMMABLE SETTINGSSetting the dateNOTE: If the day displayed is incorrect, the dateneeds resetting as follows:1. Press the set? button until SET and DATE aredisplayed.2. Press the OK button once, the year will flash onthe display.3. Press + or - to correct the year.4. Press the set? button and the month will flash onthe display.5. Press + or - to correct the month.6. Press the set? button and the day will flash onthe display.7. Press + or - to correct the day.8. Press the set? button, the DLS and ON will flashon the display.9. Press + or - to set for ON or OFF10. Press set? twice to return to the normal display.NOTE: DLS = Day Light Saving timeDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 19


ScrewTabPanelClipsDT10RF RECEIVERINSTALLATIONDANGER: 230 VOLTSDO NOT TOUCH THEELECTRICAL COMPONENTSOR CIRCUITSCAUTION:ISOLATE THE MAINS ELECTRICITYSUPPLY BEFORE STARTING ANYWORK AND OBSERVE ALL RELEVANTSAFETY PRECAUTIONSBlankingplateReceiverRecessOBSERVE ELECTRO-STATICDISCHARGE PRECAUTIONS.DO NOT TOUCH THE PCB CIRCUITNOTE: THIS ACCESSORY MUST BE FITTEDBY A COMPETENT PERSON.FAILURE TO COMPLY COULD LEADTO PROSECUTION.1. Remove the boiler outer casing and controlpanel fascia to gain access to the heatroniccontrol panel.Release the securing screwsPull the cover panel upwards to remove.Grip the tab and pull upwards to disengageclips, pull forward to remove blanking plate orexisting <strong>programmer</strong>.Ribbon cableConnector plug2. Align connector pins into the socket on thePCB and push fully home.Feed the ribbon cable into the recess.ScrewTabClips3. Align the <strong>programmer</strong> and locate the clips,push into the slots then downwards to secure.Locate the cover panel in place and securewith the screw.Replace fascia cover and outer casing beforeswitching on the electrical supply and boiler.Switch boiler on when completed.Refer to the User Instructions section fordetails of pre-set and setting programs.Programmer20OPER AT I NG & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DIGISTAT OPTIMISERINSTALLATIONDIGISTAT OPTIMISERINSTALLATIONLocation and mountingMounting the digistat1. Remove the front cover using a flat screwdriverand separate from back plate.LocationThe Digistat is a radio frequency device and forbest performance should be mounted in an openspace, no closer than 30cm to any metal objects,including wall boxes.Mount on a wall, which is not subject to directsunlight or draughts. Preferably mount on an insidewall about 1.5m (5ft) above the floor, away fromthe direct influence of radiators or other appliancesgiving off heat.2. Fix the back plate directly onto the wall usingsuitable wall plugs and screws.3. Replace the front cover by locating in positionand pushing fully onto the back cover.DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 21


DIGISTAT OPTIMISERINSTALLATIONDIGISTAT / DT10RF RECEIVERSETTING UP THE RF LINKReceiver set up:After initial start up, the colon, CH and antennasymbols should be flashing on the display.1. Press the set? button 4 times2. Press the OK button once3. Press the set? button 4 times; Lrn and OFFshould be displayed4. Press the + button so the display shows ON anda flashing antenna symbol. The learn mode is nowready to receive a signal from the transmitter duringthe next two minutesTransmitter set up:1. Take the Digistat Programmer unit and standapproximately two metres away from the boiler.2. Remove the battery cover and fit the batteries.The symbols on the receiver will stop flashing andthe display will return to the normal time display.This confirms that the radio signal is being sentand received.4. Remove the battery cover using a coin.5. Install the 2 AA batteries provided.6. Replace battery cover.The Digistat Programmer is now linked to thereceiver on the boiler.7. The Digistat is now installed and will automaticallystart to control the room temperature according tothe pre-set program 1 as shown on page 5.The display shows the correct time and datewhich is automatically set together with the actualroom temperature.22OPER AT ING & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DIGISTAT OPTIMISERINSTALLER OPTIONSInstaller OptionsIf you wish to change any of the Installer Options asshown below, enter the Installer Option Menu fromAuto mode by pressing < and + simultaneously for 5seconds.Pressing < and + again for 5 seconds will exit theMenu and return to Auto mode.Once the Installer Options screen has been selected,the < and > buttons allow you to scroll through theMenu (shown below). The + and - allow you tochange values. Once a value has been changedpressing > before exiting the Menu will save the newsetting. (The figure below shows Option 02 OFF).InstallerOptionsFunctionSelectOptionDefault02 Freeze protection On Off On04 Low Set Point C 5 HighLimit05 High Set Point C LowLimit06 Delayed Start (Energysaving feature532 32On Off Off10 Valve protection On Off Off11 Valve protection time(Mins)1 5 3Option 02 - Freeze ProtectionFreeze protection will switch on the heating if theroom temperature falls to 5°C and will then controlthe temperature at 7°C even if the Digistat is in OFFmode.The Freeze Protection default in ON.To switch off the Freeze Protection mode enter theInstaller Options Menu (Refer to Installer Options 02)and change to OFF. Press > to accept.Option 04 & 05 - Low and High Limit set points.The user temperature set points defaults are High32°C and Low 5°C, to change these limits enter theInstaller Options Menu(Refer to Installer Options 04 & 05).Option 06 - Intelligent Delayed Start(Energy saving feature).The Intelligent Delayed Start is an energy saving featurewhich automatically reduces the warm up timefor the heating system.If enabled, the start time should be set an hour earlierthan the time you want the property to reach theset temperature.Intelligent Start will delay that start time, by anamount that it has calculated based on the actualand set temperature.As the weather becomes milder, the start time isdelayed, so that fuel is not wasted bringing the roomup to temperature earlier than necessary.The Digistat calculates approximately 10 minutes toraise the temperature by 1°C, up to a maximum of6°C.Note:Intelligent Delayed Start only applies in Auto mode.Intelligent Delayed Start default is in OFF mode.To switch ON Intelligent Delayed Start enter theInstaller Options Menu (see Installer Options 06).Note:The Intelligent Delayed start option is not suitablefor underfloor application.Ensure Installer option 06 is set to OFF before finalcommissioning for underfloor application.Special Note:If the Intelligent delayed start feature isenabled, (Off changed to On in Installer option06), please inform the end user of this feature.The following special note has been added tothe user instruction to explain the adjustmentrequirement:When the delay period is operating, indicated by theflame symbol flashing, pressing any button returnsthe Digistat to auto mode allowing normal buttonoperation until the next time/ temperature event,when it will resume the delay start mode or followsthe Holiday, Manual, Override or Off modes asselected.Changes to the installer options and pre-setprogrammes must be made with the flame symbolNOT flashing.DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 23


DIGISTAT OPTIMISERINSTALLER OPTIONSOption 10 - System ProtectionIn some heating systems there may be a requirementto protect the system by operating it once a day, for agiven period.If system protection is selected the system will beoperated for a period as shown in system protectiontime (mins).System protection time is every day at 10.00am.System protection default is OFF.To enable the system protection mode enter theInstaller Options Menu (Refer to Installer Option 10).Option 11 - System Protection time (mins).System protection time can be set between 1 and 5minutes (default 3 minutes).To change this once a day on time enter the InstallerOptions Menu (Refer to Installer Option 11).How do I know when to change the batteries.When the batteries start to run low a battery iconwill flash in the display, to indicate “low battery” duringthis time the Digistat will function normally.Please replace with 2 x 1.5V (AA) Alkaline batteries.When the battery icon alone is shown in the display,the batteries are completely exhausted and theDigistat will cease to function. Re-activate byreplacing the batteries. The RF link will automaticallybe re-established.How to replace the batteriesRemove the battery cover using a coin. Replace thespent batteries with 2 x 1.5V (AA) Alkaline batteriesensuring correct orientation. Replace the batterycover pressing fully home.24OPER AT I NG & INSTA L L AT IONINST RUCT IONSDT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)


DIGISTAT / DT10RF RECEIVERMAINTENANCEDigistat Optimiser ProgrammerPart number 8 716 114 462 0Maintenance:The Transmitter requires no maintenance.The outer casing can be wiped clean using a drycloth. DO NOT use polish or detergents.These units can not be serviced.Should the existing unit fail to function correctly,check:Receiver times and program settings are correctRF signal link is set upTransmitter batteries are the correct type, fittedcorrectly and are not exhausted.Fit new batteries if in doubt.DT10RF ReceiverPart Number: 8 716 106 667 0DT10RF OPTIMISING PROGRAMMERINSTRUCTION MANUAL8 716 114 492a (08.07)OPER AT ING & INSTA L L AT IONINST RUCT IONS 25


CONTACT INFORMATIONWORCESTER, BOSCH GROUP:TECHNICAL: 08705 266241SERVICE: 08457 256206SPARES: 01905 752571LITERATURE: 01905 752556TRAINING: 01905 752526SALES: 01905 752640WEBSITE:www.worcester-bosch.co.ukO PER AT ING ANDINS TA LL ATIONINS T R U CT I O NSWorcester, Bosch GroupCotswold Way, Warndon, Worcester WR4 9SW.Tel. 01905 754624 Fax. 01905 754619www.worcester-bosch.co.ukWorcester Bosch Group is a trading name of BBT Thermotechnology UK Ltd.8 716 114 492a (08.07) 06515046001 Rev a