BDâ„¢ P100 Blood Collection Kit

BDâ„¢ P100 Blood Collection Kit

BDâ„¢ P100 Blood Collection Kit

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

BD <strong>P100</strong> <strong>Blood</strong> <strong>Collection</strong> <strong>Kit</strong><br />

Setting the Standard in Plasma Proteomics<br />

Explore


Minimize Preanalytical Variability<br />

with BD <strong>P100</strong> <strong>Blood</strong> <strong>Collection</strong> <strong>Kit</strong><br />

Human plasma contains a wide variety of proteins<br />

that hold potential as biomarkers for proteomics-based<br />

diagnostic and prognostic assays. * These proteins are<br />

subject to proteolytic degradation and modification<br />

during and after blood collection. The use of protease<br />

inhibitors – mixed immediately with blood – minimizes<br />

preanalytical variability associated with plasma sample<br />

preparation and handling.<br />

BD <strong>P100</strong> v1.1 <strong>Blood</strong> <strong>Collection</strong> <strong>Kit</strong> enables greater<br />

recovery and preservation of plasma<br />

proteins by immediately mixing with<br />

proprietary novel on-board<br />

stabilizers, specifically formulated<br />

for human plasma.<br />

Preserve Valuable Plasma Proteins<br />

† Patented<br />

* BD <strong>P100</strong> is For Research Use Only – Not For Use in Diagnostics Procedures<br />

Highlights:<br />

• On-board stabilizers provide point-of-collection<br />

protection of plasma proteins<br />

• Enhances long-term preservation by stabilizing<br />

analytes during blood collection<br />

• Innovative mechanical separator † minimizes<br />

cellular contamination<br />

• Eliminates pre-mixing and transfer tubes<br />

• Sterile and ready to use<br />

BD <strong>P100</strong> <strong>Blood</strong> <strong>Collection</strong> Tube Specifications:<br />

Total <strong>Blood</strong> Draw Volume: ~8.5 mL<br />

Plasma Yield: ~3.5 mL<br />

Anticoagulant (Spray Dried): K 2 EDTA<br />

Additive (Lyophilized): Proprietary Protein Stabilizers<br />

Storage Prior to Use: 2°C to 8°C


BD <strong>P100</strong> v1.1 Immediately Stabilizes Plasma Proteins<br />

BD <strong>P100</strong> v1.1 versus EDTA Plasma<br />

“Time 0” Gel Plot Summary of Eight Subjects (m/z 1000-2400)<br />

BD <strong>P100</strong> v1.1 versus EDTA Plasma<br />

“Time 0” Zoom Plot (m/z 1700-2050)<br />

Figure 1. Preservation of plasma proteins with BD <strong>P100</strong><br />

v1.1 <strong>Blood</strong> <strong>Collection</strong> <strong>Kit</strong>. <strong>Blood</strong> was drawn directly from<br />

eight subjects into <strong>P100</strong> and EDTA evacuated tubes. Plasma<br />

was processed within 10 minutes of blood collection by<br />

centrifugation at 2,500 x g for 15 minutes at room temperature.<br />

After blood collection, plasma was transferred into microtubes<br />

and prepared for mass spectrometry analysis or stored at –80ºC<br />

for future analysis. Peptides were isolated from the plasma<br />

samples and analyzed by MALDI-TOF MS. The mass spectra<br />

were collected in the mass range from 800 to 3200 m/z. Areas<br />

within the red rectangles demonstrate enhanced peptide<br />

stabilization in the <strong>P100</strong> samples versus EDTA plasma samples.<br />

A greater degree of proteolytic degradation is also more<br />

apparent in the EDTA plasma samples, even though samples<br />

were processed immediately upon blood collection (“Time 0”),<br />

as shown in the yellow rectangle areas.<br />

Figure 2. Enhanced stability of peptides observed in<br />

plasma samples collected with BD <strong>P100</strong> v1.1 <strong>Blood</strong><br />

<strong>Collection</strong> <strong>Kit</strong>. Regions with red arrows on this<br />

MALDI-TOF MS zoom plot (m/z 1700-2050) of two<br />

subjects demonstrates the ability of <strong>P100</strong> v1.1 to<br />

stabilize plasma peptides more effectively in the<br />

presence of protease inhibitors. These peaks are absent<br />

in the same regions on the EDTA zoom plots for both<br />

subjects. The immediate mixing of blood with the onboard<br />

protease inhibitors in BD <strong>P100</strong> tubes enhances<br />

the recovery of plasma proteins for proteomics studies.


Quantity Description<br />

12<br />

12<br />

12<br />

12<br />

<strong>Kit</strong> Contents<br />

BD <strong>P100</strong> <strong>Blood</strong> <strong>Collection</strong> Tubes<br />

Six (6) tubes/foil pouch, Two (2) foil pouches/kit<br />

BD Vacutainer ® One Use Tube Holders<br />

Single Use Only, Translucent<br />

BD Vacutainer ® Safety-Lok <strong>Blood</strong> <strong>Collection</strong> Set<br />

21 G Butterfly Needle, 12” (304.8 mm) Tubing<br />

Sterile, Use Once and Discard<br />

BD Alcohol Swab: Isopropyl Alcohol - 70%<br />

(Reference #366455 Only)<br />

1 Instructional Product Insert<br />

1 Research Use Only Certification Card<br />

North America<br />

#366455<br />

Reference Numbers<br />

Outside North America<br />

#366456


Ordering and Technical Information *<br />

Region Ordering Technical<br />

US<br />

888.237.2762 (phone orders)<br />

800.847.2220 (fax orders)<br />

800.631.0174<br />

(8:30 am – 5 pm) EST<br />

Canada 800.268.5430 ext. 5567 800.268.5430 ext. 5567<br />

All other<br />

areas<br />

Please visit www.bd.com<br />

to locate your local regional office<br />

To obtain more information on BD <strong>P100</strong> and other<br />

proteomics products, please visit our Web site<br />

www.bd.com/proteomics<br />

* BD <strong>P100</strong> is sold directly by BD Diagnostics – Preanalytical Systems<br />

Not available through distributors.


BD, BD Logo, and all other trademarks are property of Becton, Dickinson and Company. © 2007 BD<br />

03/07 VS7530-1<br />

1 Becton Drive<br />

Franklin Lakes, NJ 07417<br />

www.bd.com