10.07.2015 Views

Installation Manual

Installation Manual

Installation Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CP40 <strong>Installation</strong> <strong>Manual</strong>Hardware OverviewCabinet Tamper Input (one per panel):This NORMALLY CLOSED input can be enabled to monitor the CP40 Cabinet Tamper Switch. TheTamper Switch is provided and mounted on each CP40 cabinet.Fire Alarm Release Input (one per panel):This NORMALLY CLOSED input can be enabled to monitor an alarm condition from a Fire Alarm panelso that power to the readers and locks will drop off when a fire alarm station is activated.Fire Alarm Reset Input (one per panel):If this feature is enabled and a Fire Alarm Release has occurred, a momentary closure must be applied torestore power to the reader and lock outputs. If the Fire Alarm Reset is disabled or the input is shunted,power to the readers and locks will be restored when the Fire Alarm Release Input returns to a closed state.Spare Supervised Inputs (two per panel):The CP40 is equipped with two spare supervised inputs that may be used for point monitoring. Theseinputs require a Cansec End-of-Line Resistor pack (Part # EOLRES). Note: These spare inputs are notavailable: 1) When the SIOPT-16 Auxiliary I/O Board is installed 2) In a dial-up configuration1.4 Standard On-Board OutputsLock Outputs (one per reader):This output provides either a dry contact output, Normally Open or Normally Closed, or 12VDC @ 400 mAmax to the locking device for each reader. Since the 12VDC outputs are supplied through on-board relays,Normally Open or Normally Closed connections are available to accommodate electric strikes or magneticlocks. Lock output relays are rated at 8 Amp, 24VDC.Tamper/Forced Entry Outputs (one per reader):This is a dry contact "Form C" relay output that can be activated by any of the following conditions:1. The Cabinet Tamper Input is opened. (Both reader “A” and “B” Tamper relays are activated)2. A Reader Tamper occurs indicating that the reader has removed or pulled out from itsmounted location. This feature requires that a switch be installed and connected at the readerlocation in the reader back box. (The associated Tamper relay is activated)3. A Door Contact Input is opened without access being granted with a card or by providing amomentary closure to the Exit Button Input. (The associated Forced Entry relay is activated)Door Held Open Outputs (one per reader):This is a dry contact "Form C" relay output that will activate if the door is held open longer than thesoftware programmable time.Alarm Shunt Outputs (one per reader):This is a dry contact "Form C" relay output that will activate when a user is granted access by either using acard or by providing a momentary closure to the Exit Button Input. This output may be used for shuntingexternal alarm points.Cansec Systems Ltd. 1-2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!