InstructIons for<br />

<strong>0.5</strong>, <strong>1.0</strong> <strong>and</strong> <strong>2.0</strong> LItEr JuMBo sYrInGEs<br />

Proper care ensures improved syringe performance <strong>and</strong> long life<br />

the unique manufacturing techniques, plus the leak<br />

checks <strong>and</strong> inspection of every individual sGE syringe,<br />

ensure it meets the required sGE st<strong>and</strong>ard. to prolong<br />

the life of your syringe we recommend the following<br />

care process.<br />

1. Cleaning<br />

only use water <strong>and</strong> a mild detergent if cleaning is<br />

required. avoid the use of strong oxidizing agents,<br />

halogenated or organic solvents.<br />

after cleaning ensure internal surfaces are dry<br />

especially area between o-ring <strong>and</strong> plunger disc.<br />

refer to assembly drawing. clean outside surfaces<br />

with a soft cloth.<br />

2. Sterilization<br />

only sterilize using gas, radiation or disinfectant. do<br />

not autoclave.<br />

3. Plunger Care<br />

smooth plunger action is achieved by smearing<br />

a small amount of silicone oil on the o-ring (200<br />

fluid, 350 centistokes viscosity; dow corning).<br />

Ensure any excess is removed once plunger action<br />

feels comfortable.<br />

5. Temperature Considerations<br />

do not subject <strong>Jumbo</strong> syringes to temperatures in<br />

excess of 80 °c.<br />

6. O-ring Replacement<br />

the o-ring can be replaced or adjusted using a<br />

19 mm open spanner to loosen or tighten the<br />

hex nut (f). once the plunger is inserted into the<br />

barrel, the hex nut can be adjusted until o-ring<br />

exp<strong>and</strong>s enough to create a seal against the barrel.<br />

Description Code Qty Part No.<br />

o-ring for <strong>0.5</strong> L o-rInG (PtfE) -<strong>0.5</strong> L 1 032527<br />

o-ring for <strong>1.0</strong> L o-rInG (PtfE) -1 L 1 032532<br />

o-ring for <strong>2.0</strong> L o-rInG (PtfE) -2 L 1 032537<br />

sealing cs septa 7 mm cs septa 50 041822<br />

C<br />

I<br />

E<br />

A<br />

D<br />

F G<br />

H<br />

B<br />

A Plunger knob<br />

B End Plate<br />

C End Plate Screw<br />

D Plunger Stem<br />

E <strong>Syringe</strong> Barrel<br />

F Hex Nut<br />

G Plunger Disc<br />

H O-Ring<br />

I Sampling Ports


PLEasE do not rEturn anY sYrInGE contaMInatEd WItH radIoactIVE,<br />

InfEctIous or HaZardous MatErIaLs<br />

WaRRaNTy<br />

all sGE syringes are warranted to meet the stated quality <strong>and</strong> performance specifications <strong>and</strong> to be free of<br />

defects in material or workmanship. the warranty implies free replacement of a defective syringe only upon<br />

proper written proof of the defect <strong>and</strong> if requested by sGE, the return of the defective product in its original<br />

packaging. It does not apply to mish<strong>and</strong>ling of product by the customer, either in storage or use.<br />

aUSTRaLIa & PaCIFIC REGION<br />

sGE analytical science Pty Ltd<br />

toll free: 1800 800 167<br />

tel: +61 (0) 3 9837 4200<br />

fax: +61 (0) 3 9874 5672<br />

Email: support@sge.com<br />

EUROPE<br />

sGE Europe Ltd<br />

European Head office<br />

toll free: 00800 2790 8999<br />

toll free fax: 00800 2626 2609<br />

tel: +44 1908 568 844<br />

fax: +44 1908 566 790<br />

tel france: +33 1 69 29 80 90<br />

fax france: +33 1 69 29 09 25<br />

tel Germany: +49 (0) 6155 / 60746 0<br />

fax Germany:+49 (0) 6155 / 60746 50<br />

Email: europe@sge.com<br />

CHINa<br />

sGE shanghai representative office<br />

tel: +86 21 6407 9382<br />

fax: +86 21 6407 9386<br />

Email: china@sge.com<br />

INDIa<br />

sGE Laboratory accessories Pvt Ltd<br />

tel: +91 22 24715896<br />

fax: +91 22 24716592<br />

Email: sgeindia@vsnl.com<br />

JaPaN<br />

sGE Japan Inc<br />

tel: +81 45 222 2885<br />

fax: +81 45 222 2887<br />

Email: japan@sge.com<br />

MIDDLE EaST<br />

sGE Gulf<br />

tel: +971 6 557 3341<br />

fax: +971 6 557 3541<br />

Email: gulfsupport@sge.com<br />

UNITED STaTES OF aMERICa<br />

sGE Incorporated<br />

toll free: (800) 945 6154<br />

tel: +1 512 837 7190<br />

fax: +1 512 836 9159<br />

Email: usa@sge.com<br />

www.sge.com<br />

specifications are subject to change without notice. Mn-0221-s_revG © sGE analytical science Pty Ltd 08/2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!