Mounting fixture magnetic <strong>type</strong>:Pieces of magnet are attached onto both sides ofblocks for the “standard <strong>type</strong>” above. When thepipe material is what magnet pulls, transducers arefixed onto the pipe by magnetic power eliminatingthe use of fixing chains. If necessary, magnetpieces can be easily added for stronger magneticpower. Optional Extension CableExtends the length of transducer cable when thestandard length is not enough for the site conditions.Select the extension length from 5m (16ft), 10m (32ft),or 20m (65ft). Wall Thickness ProbeSpecified in the option code of <strong>US300PM</strong> main unit.Model codes as accessories also available forseparate/additional orders (listed later).Fluid Temperature Range:General temperature <strong>type</strong>: –20° to +60°C (–4° to +140°F)High temperature <strong>type</strong>: 0° to +200°C (32° to 392°F)Measuring Performance:Measuring range: 1.0 to 200 mm (0.04 to 7.8 inches),depends on the materialResolution: 0.01 mm (0.0004 inch) AccessoriesStandard Accessories for <strong>US300PM</strong> Main Unit:Transportation case, Measuring tape, and Built-inbattery set always come with <strong>US300PM</strong>.Fixing Hardware, Couplant, etc:Specified in the suffix code of US300FT transducers.Model codes as accessories also available forseparate/additional orders (listed later).Power Supply Adapter and AC cable:The power supply adapter and the AC cable arededicated to <strong>US300PM</strong>. Please do not use them withother devices.4Displaying Data in Graph:Display measured data of selected measuring dataset in graphic format. Marker <strong>type</strong> and color foreach line of values selectable. Scales for time-axisand value-axis can be changed from defaultcondition of automatic scaling. Graph printingfunction embedded.Displaying Statistical Data:Display statistical data of the measurement. Totaldata points, minimum, maximum, average andstandard deviation of the measured data can beshown. Data range for statistical processing can bedesignated if necessary.Exporting Text File:Parameter record and measured data can beexported to a text file. Options for exporting itemsor their formats are available.Entering Remarks:User’s remarks for each measured data can beentered and edited in the transferred data file on apersonal computer. Remarks can be displayed inthe main window of the software.Display Language:English, German(Note) Help is available only in English.Operating Environment:Personal Computer:Microsoft ® Windows ® hardware compatible, one ormore RS232 portOperating System:Microsoft ® Windows ® 98, ME, NT, 2000, XPStandard Accessories:RS232 cable, RS232 adapter 9/25* Microsoft ® and Windows ® are registered trademarks ofMicrosoft Corporation in the United States and/orother countries. Data Transfer SoftwareGeneral:The software installed on a personal computerreceives one or more records of logging data andparameter sets stored in <strong>US300PM</strong> main unit viaRS232 communication port.Data can be viewed or graphed on a PC monitor, orexported as a text file.This software works while <strong>US300PM</strong> is off-line (notmeasuring flow) where current output goes down tozero.Function:Displaying Parameter Record:Display parameter record of selected measuringdata set.Displaying Measured Data in Table:Display measured data of selected measuring dataset in table format.All Rights Reserved. Copyright © 2001, <strong>Yokogawa</strong> Electric CorporationGS 01G05B02-01E 6th Edition Aug. 22, 2013-00


5■ MODEL AND SUFFIX CODE<strong>Ultrasonic</strong> flowmeter, portable <strong>type</strong>Model Suffix code Specification<strong>US300PM</strong> · · · · · · · · · · · · · · · <strong>Ultrasonic</strong> flowmeter, portable <strong>type</strong>-A0 · · · · · · · · · · · · No current outputOutput -A1 · · · · · · · · · · · ·-A2 · · · · · · · · · · · ·One current outputTwo current outputsPower SupplyAdapter andAC cable1 · · · · · · · · · ·2 · · · · · · · · · ·3 · · · · · · · · · ·JapanUSAEurope4 · · · · · · · · · · United Kingdom5 · · · · · · · · · · Australia6 · · · · · · · · · · South Africa-2 · · · · · · · · Always 2-N· · · · · · Always NOption/PU1 · ·/PU2 · ·/FQ1 · ·/DLX · ·One binary (pulse or alarm)output (open-collector) (*1)Two binary (pulse or alarm)outputs (open-collector) (*1)Frequency output (opencollector,0 to 1kHz)Data logging extension(100,000 values)/BGT · ·/WTG · ·Tag number on nameplate (inthe nameplate label, maximum16 characters)Wall thickness probe forgeneral temperature (–20° to+60°C / –4° to +140°F)/WTH · · Wall thickness probe for hightemperature (0° to +200°C /32° to 392°F)*1: Option /PU1 and /PU2 are exclusive.Optional extension cable for portable <strong>type</strong>Model Suffix code SpecificationUS300PC · · · · · · · · · · · · · · · Optional extension cable forportable <strong>type</strong>Length -A005 · · · · · · · · · · Cable length 5m (16ft)-A010-A020· · · · · · · · · ·· · · · · · · · · ·Cable length 10m (32ft)Cable length 20m (65ft)Data transfer softwareT01.EPST02.EPSModel Suffix code SpecificationUS300SA · · · · · · · · · · · · · · · Data transfer software(Windows version) Includingconnecting kit (RS232 cable forconnection, RS232 adapter9/25)Language-1 · · · · · · · · · · · · · ·00 · · · · · · ·English / German versionAlways 00T03.EPSTransducers for portable <strong>type</strong> (*2)Model Suffix code SpecificationUS300PT · · · · · · · · · · · · · · · · Transducers for portable <strong>type</strong>Usage -G · · · · · · · · · · · · ·-W · · · · · · · · · · · · ·General purpose (IP65)Immersible (IP67)Pipe Size /FluidTemperature(*3)BG · · · · · · · · · · ·BH · · · · · · · · · · ·CG · · · · · · · · · · ·Medium & General (with 3 m /9.8 ft cable)Medium & High (with 3 m / 9.8ft cable)Large & General (with 4.4 m /14.4 ft cable)CH · · · · · · · · · · · Large & High (with 4.4 m / 14.4 ftcable)DG · · · · · · · · · · · Very large & General (with 12 m /39.4 ft cable)Mounting -C · · · · · · · · · Retaining clip <strong>type</strong> (set of twofixture (*4)clips)Fixing chain (*4)Acoustic couplantOption-S · · · · · · · · · Standard <strong>type</strong> (set of two blocks,including ruler marked length 330mm, equivalent to 13 in.)-M · · · · · · · · · Magnetic <strong>type</strong> for general temp.(–30° to +100°C / –22° to+212°F, set of two blocks,including ruler marked length330 mm, equivalent to 13 in.)-N · · · · · · · · · NoneB · · · · · · · ·C · · · · · · · ·For 25 to 1200mm (1 to 47 in.)Fixing chains of 2m / 6.5 ft lenght (2 x 2)For 1200 to 3000 mm (47 to 118 in.)Fixing chains of 2m / 6.5 ft lenght(5 2)D · · · · · · · · For 3000 to 6500 mm (118 to 255 in.)Fixing chains of 2m / 6.5 ft lenght(112)N · · · · · · · · NoneG · · · · · · General temperature <strong>type</strong> (–30°to +130°C / –22° to +266°F)H · · · · · · High temperature <strong>type</strong> (–30° to+200°C / -22° to +392°F)N · · · · · ·/TTP · ·NoneTransducer tag plate(maximum 16 characters)*2: Two sets of transducers are necessary when applyingdual channel/path measurement.*3: The alphabetic characters in the suffix code representpipe sizes and fluid temperature ranges are below.B: Medium <strong>type</strong> (25 to 400 mm / 1 to 16 in.)C: Large <strong>type</strong> (100 to 2,500 mm / 4 to 98 in.)D: Very large <strong>type</strong> (2,000 to 6,500 mm / 78 to 255 in.)G: General temperature (–30° to +130°C / –22° to +266°F)H: High temperature (–30° to +200°C / –22° to +392°F)*4: When selecting code –C or –S for mounting fixture,always select code B, C, or D for fixing chain. Whenselecting code –M for mounting fixture, fixing chains areoptional. When selecting code –N for mounting fixture,select also code N for fixing chain.T04.EPSAll Rights Reserved. Copyright © 2001, <strong>Yokogawa</strong> Electric Corporation GS 01G05B02-01E 6th Edition Aug. 22, 2013-00


6Accessories (for ultrasonic flowmeter <strong>US300PM</strong>)ModelUSPA301USPA341DescriptionWall thickness probe for general temperature(–20° to +60°C / –4° to +140°F)USPA302 Wall thickness probe for high temperature(0° to +200°C / 32° to 392°F)USPA311 Power supply adapter (100 to 240 V AC input)USPA321 AC cable (Japan)USPA322 AC cable (USA)USPA323 AC cable (Europe)USPA324USPA325USPA326AC cable (United Kingdom)AC cable (Australia)AC cable (South Africa)USPA331 Battery set (6 V 4Ah) (*5)Transportation case (*5)*5: Always comes with <strong>US300PM</strong>.Accessories (others)ModelUSPA401USPA402USPA411RS232 cable (*6)RS232 adapter 9/25 (*6)Measuring tape (*7)Description*6: Included in data transfer software US300SA asstandard.*7: Included in <strong>US300PM</strong> as standard.T05.EPST06.EPSAccessories (for transducers US300PT)ModelDescriptionUSPA001 Fixing strap (10 m / 32 ft length)USPA002 Fixing strap (20 m / 65 ft length)USPA011 Fixing clips(medium <strong>type</strong>, for pipe size 40 to 100 mm / 1.5 to 4 in., setof two clips)USPA012USPA021 Fixing bands(only for pipe size 25 to 50 mm / 1 to 2 in.)USPA032 Fixing chains (set of two extensible chains)(2 m / 6.5 ft length, equal to 600 mm / 23 in. diameter)USPA033 Repair set for fixing chainsUSPA034USPA036USPA053USPA054USPA055USPA057USPA058USPA073USPA075USPA081USPA082USPA091USPA092Fixing clips(large <strong>type</strong>, for pipe size 100 to 6500 mm / 4 to 255 in.,set of two clips)Retaining clips(set of two clips, used with fixing chains)Fixing chains (set of two extensible chains)(0.5m / 1.6 ft length, equal to 150mm / 5.9 in. diameter)USPA037 Fixing chains (set of two extensible chains)(1m / 3.2 ft length, equal to 300mm / 11.8 in. diameter)Mounting fixture short ruler <strong>type</strong> (for transducers mediumpipe size <strong>type</strong>, temperature range –30° to +200°C / –22°to +392°F, set of two blocks with 120mm / 4.7 in. ruler)Mounting fixture standard <strong>type</strong> (for transducers mediumpipe size <strong>type</strong>, temperature range –30° to +200°C / –22°to +392°F, set of two blocks with 330 mm / 13 in. ruler)Mounting fixture magnetic general temperature <strong>type</strong> (for transducersmedium pipe size <strong>type</strong>, temperature range –30° to +100°C / –22° to+212°F, set of two blocks with 330 mm / 13 in. ruler)Mounting fixture standard <strong>type</strong> (for transducers large or verylarge pipe size <strong>type</strong>, temperature range –30° to +200°C / –22°to +392°F, set of two blocks with 330 mm / 13 in. ruler)Mounting fixture magnetic general temperature <strong>type</strong> (for transducerslarge or very large pipe size <strong>type</strong>, temperature range –30° to +100°C/ –22° to +212°F, set of two blockswith 330 mm / 13 in. ruler)Additional magnets for mounting fixture magnetic generaltemperature <strong>type</strong>(for transducers medium pipe size <strong>type</strong>, temperature range–30° to +100°C / –22° to +212°F, set of two magnets)Additional magnets for mounting fixture magneticgeneral temperature <strong>type</strong>(for transducers large or very large pipe size <strong>type</strong>,temperature range –30° to +100°C / –22° to +212°F,set of two magnets)Ruler for mounting fixture(marked length 120 mm, equivalent to 4.7 in.)Ruler for mounting fixture(marked length 330 mm, equivalent to 13 in.)Acoustic couplant general temperature <strong>type</strong>(100 g, –30° to +130°C)(0.22 lb, –22° to +266°F)Acoustic couplant high temperature <strong>type</strong>(100 g, –30° to +200°C)(0.22 lb, –22° to +392°F)F07.EPSAll Rights Reserved. Copyright © 2001, <strong>Yokogawa</strong> Electric CorporationGS 01G05B02-01E 6th Edition Aug. 22, 2013-00


268(10.6)315(12.4)115(4.53)18(0.7)22(0.9) 7■ DIMENSIONAL DRAWINGS<strong>Ultrasonic</strong> flowmeter <strong>US300PM</strong>Unit: mm (inch)Sensor element276(10.9)258(10.2)Transducer cablesø1543 (1.7)XYF02.EPSTransducers US300PT-C, US300PT-DSensor elementTransducer cables34(1.3)ø1560(2.4)30(1.2)XYF01.EPSF03.EPSWeight: 3.9 kg (8.60 lb)(incl. battery set)Transducers US300PT-BLength / WeightTransducersUS300PT-BUS300PT-CUS300PT-DX m (inch) Y m (inch) X+Y m (inch) Weight kg (lb)2.0 ( 78.7) 1.0 ( 39.4) 3.0 (118.1)2.0 ( 78.7) 2.4 ( 94.5) 4.4 (173.2)5.0 (196.9) 7.0 (275.6) 12.0 (472.4)0.6 (1.32)1.2 (2.65)2.2 (4.85)T08.EPSOptional extension cable US300PC-Aø15LF04.EPSLength / WeightOptional extension cableUS300PC-A005US300PC-A010US300PC-A020L m (inch)5.0 (196.9)10.0 (393.7)20.0 (787.4)Weight kg (lb)0.4 (0.88)0.6 (1.32)1.6 (3.53)T09.EPSAll Rights Reserved. Copyright © 2001, <strong>Yokogawa</strong> Electric Corporation GS 01G05B02-01E 6th Edition Aug. 22, 2013-00


ø22(0.9)48(1.9) Wall thickness probe for general temperature (–20° to +60°C / –4° to +140°F)(option /WTG or model USPA301)8Unit: mm (inch)ø15LF05.EPSWall thickness probe for high temperature (0° to +200°C / 32° to 392°F)(option /WTH or model USPA302)ø15LF06.EPSLength / WeightWall thickness probe/WTG or USPA301/WTH or USPA302L m (inch)1.5 (59.1)1.2 (47.2)Weight kg (lb)0.17 (0.37)0.19 (0.42)T10.EPSOrdering InformationSpecify the following when ordering.1.Model, suffix and option code(1)First, specify the main unit <strong>US300PM</strong> and the transducers US300PT (one set of transducers when using only onechannel or two sets when using two channels). The transducers can be added later.(2)<strong>US300PM</strong> main unit is not normally quipped with current outputs, pulse outputs, or alarm outputs as standard. Specifythe corresponding code when necessary like –A01 or –A02 for current outputs, and /PU1 or /PU2 for pulse or alarmoutput.(3)Specify the wall thickness probe if necessary in the option code for the main unit <strong>US300PM</strong> (code /WTG or /WTH).They can be purchased later as model USPA301 or USPA302.(4)Specify the optional extension cable if necessary.(5)Specify the accessories when necessary or suitable. For example we may use “fixing strap” instead of “fixing chain” tofix the transducers to the pipe. Please consult us for the details.2. Tag number (when necessary)Maximum sixteen (16) characters for the cases below.(1) In the nameplate lable of the main unit <strong>US300PM</strong> (necessary to specify the option /BGT at the same time)(2) In the tag plate for the transducers US300PT (necessary to specify the option /TTP at the same time)All Rights Reserved. Copyright © 2001, <strong>Yokogawa</strong> Electric CorporationGS 01G05B02-01E6th Edition Aug. 22, 2013-00