GREENSTAR CAMRAY UTILITY &UTILITY SYSTEMFLOOR STANDING OIL FIRED CONDENSING BOILERCONVENTIONAL FLUE & ROOM SEALED FLUEFOR FULLY PUMPED OPEN VENT OR SEALED CENTRAL HEATING SYSTEMS ANDDOMESTIC HOT WATER CYLINDERSFor use with the following Greenstar oil fired appliances:Greenstar Camray Utility 12/18, 18/25, 25/32Greenstar Camray Utility System 12/18, 18/25, 25/32THE APPLIANCE IS FOR USE WITH 28SECOND KEROSENE ONLYGBUSER INSTRUCTIONS& CUSTOMER CARE GUIDE


CONTACT INFORMATIONUSER INSTRUCTIONS &CUSTOMER CARE GUIDE<strong>Worcester</strong>, <strong>Bosch</strong> Group:Service call centres:UK TEL: 08457 256206FAX: 08457 757536SCOTLAND ONLY FAX: 01506 441687Other enquiries: TEL: FAX:MAIN RECEPTION: 01905 754624 754619TECHNICAL: 08705 266241SPARES: 01905 752571LITERATURE: 01905 752556SALES: 01905 752640WEBSITE: www.worcester-bosch.co.ukWATER TREATMENT:FERNOX 01799 550811www.fernox.comSENTINEL 0151 420 9595www.betzdearborn.com/sentinelFLUE TERMINAL GUARDS:WORCESTER, BOSCH GROUPOIL FIRING TECHNICAL ASSOCIATION:OFTEC 0845 6585080www.oftec.orgPLEASE READ THESE INSTRUCTIONSCAREFULLY BEFORE OPERATING YOURAPPLIANCE.THESE INSTRUCTIONS ARE APPLICABLETO THE WORCESTER, BOSCH GROUPAPPLIANCE MODEL(S) STATED ON THEFRONT COVER OF THIS MANUAL ONLY ANDMUST NOT BE USED WITH ANY OTHERMAKE OR MODEL OF APPLIANCE.IF YOU ARE IN ANY DOUBT CONTACT THEWORCESTER, BOSCH GROUP TECHNICALHELPLINE.PLEASE KEEP THESE INSTRUCTIONS WITHTHE INSTALLATION AND SERVICINGINSTRUCTIONS IN A SAFE PLACE OR WITHTHE APPLIANCE AFTER INSTALLATION ORSERVICING.DO NOT INTERFERE WITH ANY SEALEDCOMPONENTS.ABBREVIATIONS:Ø Diameter.CH Central Heating.DHW Domestic Hot Water.TRV Thermostatic Radiator Valve.IP Ingress Protection.CF Conventional flue.RS Room sealed flue.N/A Not allowed.SEDBUK Seasonal Efficiency for DomesticBoilers in the United Kingdom.OFTEC Oil Firing Technical Association for thePetroleum Industry.USER INSTRUCTIONS &CUSTOMER CARE GUIDEGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


CONTENTSINTRODUCTIONSAFETY PRECAUTIONS 2EXCELLENCE COMES AS STANDARD 3GENERAL INFORMATION 4-6USING YOUR APPLIANCECONTROLS 7OPERATING THE APPLIANCESwitching the boiler on/off 8Setting the heating temperature 8Controlling central heating 8Fault conditions 9INTRODUCTIONUSING YOURAPPLIANCEENERGYSAVINGENERGY SAVINGTIPS ON ENERGY SAVING 10-11MAINTENANCEMAINTENANCEMAINTAINING YOUR APPLIANCE 12FAULT FINDING 13FAULT OR BREAKDOWN 14GUARANTEEGUARANTEEYOUR GUARANTEE 15GUARANTEE REGISTRATION 16NOTESGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)CONTENTS1


INTRODUCTIONOIL SMELLS, LEAKS OR FUMES FROM THEAPPLIANCE: Extinguish any naked flames. Open windows and doors. Switch off the appliance electricity supply. Isolate the fuel supply to the boiler. Contact installer/service engineer.HEALTH & SAFETY:The appliance contains no asbestos and nosubstances have been used in theconstruction process that contravene theCOSHH Regulations (Control ofSubstances Hazardous to HealthRegulations 1988). Where applicable, theCE mark indicates compliance with relativeEU Directives.COMBUSTIBLE AND CORROSIVEMATERIALS:Do not store or use any combustiblematerials (paper, thinners, paints etc.) insideor within the vicinity of the appliance.The combustion air must be kept clear ofchemically aggressive substances which cancorrode the appliance and invalidate anywarranty.SAFETY PRECAUTIONSFITTING & MODIFICATIONS:Fitting the appliance and any controls to theappliance may only be carried out by acompetent engineer in accordance with therelevant Installation Regulations.Flue <strong>system</strong>s must not be modified in anyway other than as described in the fittinginstructions.Any misuse or unauthorised modifications tothe appliance, flue or associatedcomponents and <strong>system</strong>s could invalidatethe warranty. The manufacturer accepts noliability arising from any such actions,excluding statutory rights.This appliance is suitable for use with 28second kerosene only, no other fuel mustbe used.SERVICING:The user must have the <strong>system</strong> regularlyserviced by a competent, qualified OFTECregistered engineer using approved spares,to help maintain the economy, safety andreliability of the appliance.The appliance should be serviced once eachyear after installation unless the installationconditions and usage demand more frequentservices.2SAFETY PRECAUTIONSDO NOT OPERATE THE APPLIANCE WHEN: The appliance, flue or <strong>system</strong> is incorrectlyfitted, faulty or damaged.The flue terminal outlet fitted on the outsidewall or roof is obstructed or damaged.There are fumes, fuel leaks or fuel smellsfrom the fuel supply, appliance or flue <strong>system</strong>. The <strong>system</strong> is empty, frozen or unpressurised(sealed <strong>system</strong>s). The condensate pipe is blocked or restricted.The appliance clearances are inadequate.The air supply is restricted or vents damaged.GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


EXCELLENCE COMES ASSTANDARDThank you for purchasing a Greenstar oil firedcondensing boiler from <strong>Worcester</strong>, <strong>Bosch</strong>Group. The company prides itself onmanufacturing boilers to the strictest qualitycontrol standards throughout every stage ofproduction.<strong>Worcester</strong>, <strong>Bosch</strong> Group has led the field ininnovative appliance design and performance formore than 40 years. This heritage means allproducts are of exceptional quality and provenreliability.INTRODUCTIONThe condensing range in particular, is extremelyenergy efficient, converting more of the fuelconsumed into heat offering you economicalrunning costs and value for money. It sits inSEBUK band A, at the top of the energy ratedappliances available.There is also the assurance of our no-nonsenseparts and labour guarantee - backed up by anoptional servicing and maintenance contract tokeep your boiler operating at peak condition andefficiency.To find out more about <strong>Worcester</strong>, <strong>Bosch</strong>Group, use the 'Contact Information' shown onthe inside front cover.GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)EXCELLENCE COMES ASSTANDARD3


INTRODUCTIONRead these instructions carefully to get the bestfrom your appliance.CENTRAL HEATING SYSTEMS:During the first few hours of operation of thecentral heating <strong>system</strong>, check that all radiatorsare being heated at an even rate.If the top of a radiator is at a lower temperaturethan the bottom then it should be vented byreleasing air through the venting screw at the topof the radiator. Ask your installer to show youhow this is done. Repeated venting will reducethe quantity of water in the <strong>system</strong> and this mustbe replenished for safe and satisfactoryoperation of the appliance.When excessive venting or water leaks are foundin the <strong>system</strong> you must contact a serviceengineer to inspect the installation and rectifyany fault.Only use additives compatible with the applianceand <strong>system</strong>. Use of incompatible additives cancause damage and will invalidate the applianceguarantee.Frost protection:Use a suitable anti-freeze/inhibitor at the correctstrength to protect against freezing.A frost themostat should be fitted to the <strong>system</strong>where the <strong>system</strong> is most exposed and at risk offreezing.Sealed heating <strong>system</strong>s:Where the appliance is fitted to a sealed heating<strong>system</strong> your installer will inform you of theminimum and maximum pressure which must beindicated on the pressure gauge.Regularly check the pressure is maintained andcontact your installer or maintenance engineer ifthere is a noticeable, permanent drop inpressure. If the <strong>system</strong> loses pressure it shouldbe repressurised and the cause of the lossinvestigated.GENERAL INFORMATIONCONDENSATE:This is a high efficiency appliance usingcondensing technology which will under normaloperation produce a regular discharge ofcondensate to drain and at times, give out aplume of water vapour from the flue terminal.ROOM THERMOSTAT:A room thermostat must be fitted to control thecentral heating. Refer to instructions suppliedwith the room thermostat for information onsiting and setting.THERMOSTATIC RADIATOR VALVES:It is recommended that this type of valve is fittedto all but one of the radiators (or at least those inthe sleeping accommodation). The remainingradiator, which must be where the roomthermostat is located, should be un-controlledand must be left open.Pressure gaugeon the CamrayUtility Systemmodel.4GENERAL INFORMATION GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


GENERAL INFORMATIONBOILER LOCATION:This boiler is only suitable for installing internallywithin a property at a suitable location onto afixed rigid surface at least the same size as theboiler and capable of supporting the boilerweight.The boiler is not suitable for external installationunless a suitable enclosure is provided.Roof space installations must fully conform toBS 5410 part 1 section 4.6.9.INTRODUCTION1200mm300mm**380mm** The boiler can be installed under a worktopas long as: The worktop above the boiler is removablefor maintenance. There is at least 10mm clearance above theboiler.The front of the boiler is not enclosed.1155mm5mm*5mm*600mmConventional flued appliances:Minimum area of of air inlet for combustion:Model Area (cm )212/18 7218/25 11025/32 138VENTILATION:Air vents must be functional at all times and theair supply must not be restricted orcontaminated.The appliance clearances must meet theminimum shown opposite for servicing andventing purposes.* If this clearance is less than 75mm the flue'knock-out' panel sections must be removed toimprove air circulation and cooling.Do not place clothes or objects to hinder the aircirculation required by the appliance.Conventional flue appliances require anadequate supply of fresh air which must bedelivered to the boiler for combustion purposesthrough a permanent inlet, such as an air brick,into the area where the boiler is situated.GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)GENERAL INFORMATION5


INTRODUCTIONGENERAL INFORMATIONIf a cupboard or compartment which is to beused for storage or airing is built around theappliance after installation there must be anon-combustible partition around the boiler.Further information can be found in BS 5410which also describes venting requirements.MINIMUM AIR VENT AREA (cm 2 ) FORAPPLIANCES INSTALLED IN A COMPARTMENT:1 Internal air to and from a space/room inside the building.2 External air to and from directly outside the building.Conventional flue:Model12/1818/2525/32Internal 1 ventilationHighLevelLowLevelExternal 2 ventilationHighLevelLowLevel143 215 72 143220 330 110 220275 413 138 275Venting compartments: Ventilation must be provided for boilers fittedinto compartments as described in BS 5410 A minimum of 2 air vents must be fitted, oneat low level and another at high level ontothe same wall using the same air forcirculation. Combustion air must not be taken from aroom or internal space containing a bath orshower and must not communicate with aprotected area such as a hall, stairway,landing, corridor, lobby, shaft etc. Air vents must allow access for clean free airand must be sited to comply with the flueterminal position requirements. Air ducting runs must not exceed 3m. Low level air vents must be less than450mm from the floor. A warning label must be added to the ventswith a statement to the effect: ''Do not blockthis vent. Do not use for storage”.Room Sealed flue:Model12/1818/2525/32Internal 1 ventilationHighLevelLowLevelExternal 2 ventilationHighLevelLowLevel143 143 72 72220 220 110 110275 275 138 1386GENERAL INFORMATION GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


CONTROLSUTILITY & UTILITY SYSTEM MODELS:ATemperature control.BReset button - burner lock-out indicator/resetbutton (on the burner control box behindthe front panel).ADCBECDEReset button - boiler overheat thermostat(behind front panel).Reset button - flue overheat thermostat(behind front panel).Front panel.USING YOURAPPLIANCEGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)CONTROLS7


OPERATING THE APPLIANCEUSING YOURAPPLIANCETEMPERATURE CONTROL:SWITCHING THE BOILER ON/OFF:To switch on the boiler; turn ON the water,oil and electricity supply to the boiler.Check the programmer/timer is correct andit is set to ON.Set the room thermostat to the desiredsetting.Open and set thermostatic radiator valves asrequired.Turn the boiler water temperature control tothe required setting.To switch off the boiler; turn theprogrammer/timer to OFF for heating andhot water. If the appliance is left unused andexposed to freezing conditions; shut off allthe mains supplies, isolate the boiler anddrain the <strong>system</strong> and boiler.SETTING HEATING TEMPERATURE:Turn the control clockwise to increase theradiator temperature.Turn the control anti-clockwise to reduce theradiator temperature.The minimum and maximum ranges of theheating control positions are approx. 55°C to81°C.CONTROLLING CENTRAL HEATING: Set the programmer/timer to the correct timewith the required ON/OFF periods.Turn the room thermostat to the temperaturerequired.Set thermostatic radiator valves to therequired temperature for each room.8OPERATING THE APPLIANCE GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


a), c)OPERATING THE APPLIANCEFAULT CONDITIONS:The burner lockout indicator/reset button canindicate some basic faults:CDNormal operation:a) Lockout indicator OFF:The burner will cycle on and off under the controlof the programmer/timer and the thermostats.USING YOURAPPLIANCEb)Lockout indicator light:b) Light ON, boiler not firing:1. Check oil level in the oil storage tank.2. Press button (B). Boiler should fire.3. If no response, wait 2 minutes - pressreset button (B) again.4. If lockout light stays on, do not attemptfurther resets. Contact your serviceengineer for advice.Bc) Light OFF, boiler not on, no heating/hotwater:1. Ensure there is a power supply to the boiler.2. Check the programmer is set to ON forheating.3. Check the setting of the room thermostat,boiler temperature control/tank thermostat.4. Press reset buttons (C and D).5. If the boiler stays off contact your serviceengineer for advice.BCDGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)OPERATING THE APPLIANCE9


TIPS ON ENERGY SAVINGHeating economically:The boiler is designed to provide a high level ofcomfort while keeping oil consumption and theresulting environmental effect as low as possible.The temperature control on the boiler should beset as low as possible while still maintaining acomfortable room temperature.ENERGYSAVINGThe temperature of each room can be setindividually using the thermostatic radiator valves(except the primary room with the roomthermostat).Roof insulation:Around 30% of the heat loss from a property isthrough the roof. Replace any old insulation withnew insulation, preferably to a minimumthickness of 200mm.Window frames:Single glazed windows, particularly those withsteel frames, can lose a great deal of heat.Consideration should be given to replacementwith PVCu or wooden framed double glazedunits.Curtains:Lined curtains, or heavier full length curtains canprovide excellent insulation. However, alwaysensure that the curtains do not drape overradiators.Draughts:Try to ensure that draughts around doors,windows, letterboxes and keyholes etc., arereduced by using a suitable draught excluder.Warning: do not block or seal any air ventsthat are installed to ensure the centralheating boiler (or other appliance) operatesafely.10TIPS ON ENERGY SAVINGGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


TIPS ON ENERGY SAVINGRoom thermostats:Reducing the setting of the room thermostat by1°C can reduce fuel consumption by up to 10%.New control <strong>system</strong>s:Upgrade your heating control <strong>system</strong> with thelatest equipment available. The minimum level ofcontrol for a heating <strong>system</strong> is aprogrammer/timer, interlocking room thermostatand thermostatic radiator valves.Radiators:More often than not radiators will be sitedunderneath a window, so the warm air from theradiator heats the colder incoming air from thewindow.ENERGYSAVINGThe performance of the radiator will be affectedif the curtains are allowed to drape over theradiator or shelves are fitted above it.The positioning of furniture and tables in front ofthe radiator should also be avoided.It is advisable to manually adjust all radiatorvalves every 2-3 months to prevent them fromsticking. It is also important that the plastic topsof all valves are always in position and notcracked or damaged to help prevent accidents.Care should be taken when vacuum cleaningcarpets to avoid damage to valves and pipework.The heating <strong>system</strong> and the outputs of theradiators have been carefully selected by yourinstaller. The temperature obtainable in any givenroom is dependent on all radiators beingoperated at the same time. If you decide to turnoff radiators in unused rooms, spare bedroomsetc., you may experience slightly lower roomtemperatures in rooms adjacent to unheatedrooms.GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)TIPS ON ENERGY SAVING11


MAINTAINING YOUR APPLIANCEYour new appliance represents a long terminvestment in a reliable, high quality product.In order to realise its maximum working life andto ensure it continues to operate at peakefficiency and performance, it is essential thatservicing and maintenance checks are performedat least once a year by a competent person.If you would like to know more about servicingoptions from <strong>Worcester</strong>, <strong>Bosch</strong> Group pleasevisit www.worcester-bosch.co.uk.Please tick the appropriate box on your warrantyregistration card for further details on the<strong>Worcester</strong>, <strong>Bosch</strong> Group service contract.In addition to the service contract we arepleased to offer a one-off annual service orbreakdown cover.MAINTENANCEWhen your appliance requires servicing pleasecontact the <strong>Worcester</strong>, <strong>Bosch</strong> Group contactcentre (see inside front cover for details).Maintenance tips:Regularly check the oil level in the tank.Regularly check the <strong>system</strong> pressure, ask yourinstaller for guidance.Do not obstruct the flue outlet or the air inlet.12MAINTAINING YOURAPPLIANCEGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


FAULT FINDINGProblem Cause RemedyDesired room temperatureis not reachedThermostatic radiatorvalve(s) set too lowIncrease thermostaticradiator valve setting(s)Room thermostat set toolowIncrease room thermostatsettingTemperature control forflow on boiler set toolowIncreasetemperature controlsettingAir trapped in heating<strong>system</strong>Bleed radiators, if fitted toa sealed <strong>system</strong> rechargeheating <strong>system</strong>Desired room temperatureexceeded by large amountRadiators are too hotTurn down thermostaticradiator valves / room statMAINTENANCETemperature rises insteadof fallingClock is incorrectly setCheck settingNo display or display unitdoes not respondMomentary power failureSwitch off appliance atmaster switch, wait a fewseconds then switch onagainHot water temperature toolowHot water tanktemperature set too lowCheck settingHot water not in timedperiod on the programmerCheck programmersettingsTemperature control onboiler set too lowCheck settingGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)FAULT FINDING13


MAINTENANCEFAULT OR BREAKDOWNThis appliance is supported in the UK by<strong>Worcester</strong>, <strong>Bosch</strong> Group, part of BBTThermotechnology UK Ltd.Specialist factory trained Service Engineers areavailable to attend in the unlikely event that abreakdown occurs on this appliance.No charge will be made for parts and/orlabour providing: An appliance fault is found and theappliance has been installed within the past24 months Reasonable evidence of this must besupplied on request A call-out charge will be made where: The appliance has been installed for over 24months OR Our Field Service Engineer finds no faultwith the appliance (see Note). OR Evidence cannot be provided that the firstyear service inspection has been carried out.(i.e. an entry in the service interval recordfound at the rear of the appliance installationand servicing manual). OR The cause of breakdown is misuse or withother parts of your plumbing/heating <strong>system</strong>,or with equipment not supplied by BBTThermotechnology UK Ltd.Note: NO APPLIANCE FAULT IS FOUND ONOVER 30% OF ALL SERVICE CALL OUTS.circumstances this will be from 1 to 3 workingdays (excluding weekends) for prioritybreakdown situations (no hot water and/orheating).Invoices for attendance and repair work carriedout on this appliance by any third party will notbe accepted.Utility and Utility System models:APPLIANCE DATA LABELThe data label can be found on the inside of theright hand side panel.To access first remove the front panel: Gently pull front panel to release lugs andremove from appliance.To replace front panel: Gently push the panel in to place (from theedges so as not to damage the panel) untilthe studs locate in their connectors.Kitchen models:APPLIANCEDATA LABELDATA LABEL14Please read this guide carefully to gain a goodunderstanding of the operation of your appliance.In the case of a suspected fault, refer to the faultfinding section of this guide.If in doubt contact <strong>Worcester</strong>, <strong>Bosch</strong> Groupquoting the boiler serial and model number.These numbers are printed on a Data Labelwhich is located as shown opposite. (You canrecord this information on the inside back coverof this manual.)In the unlikely event of an appliance fault orbreakdown please call the contact centre (seeinside front cover for details). Your serviceadministrator will arrange for an Engineer to callwith the minimum of delay. Under normalUtility shown.FAULT OR BREAKDOWN GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


YOUR GUARANTEEThis appliance is guaranteed against faultymaterials or workmanship for a period of 24calendar months (60 months for the primary heatexchanger) from the date of installation subjectto the following conditions: That during the period of this guarantee anycomponents of the unit which are proved tobe faulty or defective in manufacture will beexchanged or repaired free of materialcharges and free of labour charges ifrepaired directly by BBT ThermotechnologyUK Ltd. Invoices for attendance and repair ofthis appliance by third parties will not beaccepted for payment by BBTThermotechnology UK Ltd. That the householder may be asked to provethe date of installation, that the appliancewas correctly commissioned and that the 12month service has been carried out to thesatisfaction of BBT Thermotechnology UKLtd, when requested. The guarantee cardmust then be returned within 30 days ofinstallation. That any product or part thereof returned forservicing under the guarantee must beaccompanied by a claim stating the Model,Serial Number and Date of Installation.That BBT Thermotechnology UK Ltd will notaccept responsibility for damage caused byfaulty installation, neglect, misuse,accidental damage or non-observance ofthe instructions contained in the Installationand Users Instructions leaflets.That the appliance has been used only fornormal domestic purposes, for which it wasdesigned. That this guarantee applies only toequipment purchased and used in mainlandGreat Britain.This guarantee is given in addition to all yournormal statutory rights.GUARANTEE<strong>Worcester</strong>, <strong>Bosch</strong> Group is a trading name ofBBT Thermotechnology UK Ltd.GREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)YOUR GUARANTEE15


GUARANTEE REGISTRATIONYou should complete and return the postpaidGuarantee Registration Card within 30 days ofinstallation.Returning your card will register you as theowner of your new appliance and will assist us inmaintaining an effective and efficient customerservice by establishing a reference andpermanent record for your boiler.This does not affect your statutory rights.For your own record:GUARANTEEModelSerial No.(See identity label inside appliance casing)Type / sizeDate of installationInstaller details16GUARANTEEREGISTRATIONGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)


NOTESNOTESNOTESGREENSTAR CAMRAY UTILITY/UTILITY SYSTEM 12/18 - 18/25 - 25/328 716 111 983a (02.07)NOTES17


USER INSTRUCTIONS &CUSTOMER CARE GUIDEEXCELLENCE COMES AS STANDARD<strong>Worcester</strong>, <strong>Bosch</strong> GroupCotswold Way, Warndon, <strong>Worcester</strong> WR4 9SW.Tel. 01905 754624 Fax. 01905 754619www.worcester-bosch.co.uk<strong>Worcester</strong>, <strong>Bosch</strong> Group is a brand name of BBT Thermotechnology UK Ltd.8 716 111 983a (02.07)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!