10.07.2015 Views

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareFunctional descriptionResponse to bus voltage failure, bus or mains voltage return or ETS programmingThe switching states or brightness values of the <strong>DALI</strong> groups following bus voltage failure, bus ormains voltage return or after ETS programming can be set separately.Setting the behaviour after programming with the ETSThe “Behaviour after ETS programming” parameter is created separately for each group in the “Groups- [x] group name" parameter node (x = group number 1...32). This parameter can be used toparameterize the brightness behaviour independently of the behaviour after bus/ mains voltage return.• Set the parameter to "No change".After the ETS programming, the <strong>DALI</strong> devices of a group will show not reaction and keep the currentbrightness value or remain switched off.• Set the parameter to "Switch-off".The group will be switched off after the programming with the ETS has been completed, .• Set the parameter to "Brightness value". Select the required brightness value in the selection field.The group will be set to the brightness value specified in the selection field. The adjustable valuemust be within the limits of the parameterized maximum and minimum brightness.• The parameterized behaviour will be executed after every application or parameter download by theETS. A simple download of the physical address alone or partial programming of only the groupaddresses will cause this parameter to be disregarded and the "Response to bus voltage return"parameter to be executed.• An ETS programming can only take place if the <strong>DALI</strong> <strong>Gateway</strong> is connected to the mains voltage.• A switching status set after an ETS programming cycle will be tracked in the feedback objects.• When set to “No change”: the communication objects of the <strong>Gateway</strong> will be initialized with “0” after aprogramming operation. In this case, the switching status or brightness value feedback returned willcorrespond to the 'true' brightness status of the group only if the group has been activated at leastonce via the bus or manual control. Feedback objects that are set to actively transmit will transmit notelegram.• An ETS programming operation will terminate the active manual control mode.• After programming with the ETS, the disable functions as well as the forced-control positions arealways deactivated.• The <strong>DALI</strong> <strong>Gateway</strong> will initialize after the ETS programming and will configure the connected deviceswith the group parameters via the <strong>DALI</strong> line. This is the reason why the entire <strong>DALI</strong> system has to beconnected and fully activated after programming with the ETS. If at this point an error occurs in the<strong>DALI</strong> line (e.g. short-circuit, cable break), the <strong>DALI</strong> configuration cannot take place. The error has tobe eliminated and the programming with the ETS has to be repeated! During the configuration, " "will be shown on the front panel in the 7-segment display.Seite 50 von 130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!