Systems

gsc.com.ua

Systems

Overview ................. 0SystemsCabinets.................. 1Climate Control....... 2Cases ...................... 3Subracks/19" chassis............. 4Modules .................. 5Systems .................. 6Power supplyunits........................ 7Backplanes ............. 8Accessories ............ 9Appendix............... 106.0 UK 08/2003For further information ... www.schroff.biz


SystemsOverview.............. 6.0VMEbusSubrack systems:3 U, 5-slot ..................6.24 U, 8-slot ..................6.37 U (6+1), 12-slot.......6.47 U (1/2+6+1/2),12-slot........................6.58 U (1+6+1), 21-slot ..6.6VME 64xbusSubrack systems:4 U, 8-slot ..................6.77 U (1/2+6+1/2),12-slot........................6.810 U (2+6+2),21-slot........................6.9Drive unit compartment1 U............................6.10CompactPCISubrack systems:1 U with rear I/O ......6.123 U with rear I/O ......6.134 U with rear I/O ......6.145 U with rear I/O ......6.156 U with rear I/O ......6.166 U + 1 U withrear I/O.....................6.17System for telecomapplications 6 U + 4 Uwith rear I/O.............6.18Air flow barrier ........6.19U-profile panel for 3 Urear I/O.....................6.20Circuit board covers 6.20Advanced TCASystems, backplanes,front panels . . . . . . 6.22AccessoriesFan Control Module(FCM) .......................6.24Chassis MonitoringModule (CMM)..........6.25Side panels, coverplates, horizontalrails, guide rails.......6.26Front panels, partialwidth front panels,IEEE handles ............6.26Drive units ...............6.26Backplanes/bridges.6.26Power supplies ........6.27DC fans/fan insert....6.27For further information ... www.schroff.bizUK 08/20036.1


Systems – VME bus3 U subrack system unit with 5-slot backplaneVME bus Shielded 19" subrack for horizontal board mounting VME system backplane J1/J2 monolithic, 5 slots, 6 U,horizontally mounted Open Frame power supply with 200 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarm10002004Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with perforated panels as wellas front handles (RAL 7016)2 1 Open Frame power supply 200 W with wide rangeinput 100 – 240 V (5 V/35 A, 12 V/7.5 A, -12 V/5 A)3 1 Vented front panel 3 U with display module and mainsswitch4 1 Speed-controlled fan for cooling of the boards5 1 FCM module for fan monitoring/control6 1 Mounting space for installation of max. 5 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME system backplane J1/2 monolithic, 5 slots, 6 U,horizontally mounted8 1 Complete AC/DC wiring9 1 AC power input connector IEC 320 and filter fitted inrear panel10002050Order InformationHeight Number of Width Depth Order no.slotsU HP mm3 5 84 277.5 20836-310For further information www.schroff.biz/oneClickoneClick code = Order no.100020516.2UK 08/2003For further information ... www.schroff.biz


Systems – VME bus4 U subrack system unit with 8-slot backplaneVME bus Shielded 19" subrack for horizontal board mounting VME system backplane J1/J2 monolithic, 8 slots, 6 U,horizontally mounted Open Frame power supply with 350 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarmDelivery comprises (completely assembled and wired)10002001Item Qty Description1 1 19" subrack, shielded, with perforated panels as wellas front handles (RAL 7016)2 1 Open Frame power supply 350 W with wide rangeinput 100–240 V (5 V/45 A, 12 V/12 A, -12 V/9.5 A)3 1 Vented front panel, 4 U, with display module andmains switch4 1 Speed-controlled fan for cooling of the boards5 1 FCM module for fan monitoring/control6 1 Mounting space for installation of max. 8 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME system backplane J1/J2 monolithic, 8 slots, 6 U,horizontally mounted8 1 Complete AC/DC wiring9 1 AC power input connector IEC 320 and filter fitted inrear panelOrder Information10002052Height Number of Width Depth Order no.slotsU HP mm4 8 84 277.5 20836-415For further information www.schroff.biz/oneClickoneClick code = Order no.10002053For further information ... www.schroff.bizUK 08/20036.3


Systems – VME bus7 U (6+1) subrack system unit with 12-slotbackplaneVME bus Shielded 19" subrack VME system backplane J1/J2 monolithic, 12 slots, 6 U Open Frame power supply with 450 W, wide range input andPFC Active heat dissipation of the power supply and boards bymeans of 1 U high, removeable fan unit (Hot Swap)10002003Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with vented cover and baseplates as well as front handles (RAL 7016)2 1 Open Frame PSU 450 W with wide range input100 – 240 V (5 V/70 A, 12 V/10 A, -12 V/8 A)3 3 Speed-controlled fans for cooling of the boards unit(Hot Swap)4 1 FCM module for fan monitoring/control5 1 Mounting space for installation of max. 12 boards 6 U160 mm deep. Guide rail including ESD clips (ESDclips mounted at front bottom)6 1 Blank panel 6 U 36 HP7 1 VME system backplane J1/J2 monolithic, 12 slots, 6 U8 1 Complete AC/DC wiring9 1 6 U/84 HP hinged rear panel10 1 AC power input connector IEC 320 and filter fitted inrear panel10002054Order InformationHeight Number of Width Depth Order no.slotsU HP mm7 (6+1) 12 84 355 20836-715Note Other backplanes and power supplies available on request Filter mat on requestFor further information www.schroff.biz/oneClickoneClick code = Order no.100020556.4UK 08/2003For further information ... www.schroff.biz


Systems – VME bus7 U (1/2+6+1/2) subrack system with 12-slotbackplaneVME bus Shielded 19" subrack VME system backplane J1/J2 monolithic, 12 slots, 6 U Open Frame power supply with 450 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarm10002002Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with closed cover and base aswell as front handles (RAL 7016)2 1 Open Frame power supply 450 W with wide rangeinput 100–240 V (5 V/70 A, 12 V/10 A, -12 V/8 A)3a 1 Display module3b 1 Power switch4 3 Speed-controlled fans for cooling of the boardsmounted on the hinged rear panel (5 U)5 1 FCM module for fan monitoring/control6 1 Mounting space for installation of max. 12 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME system backplane J1/J2 monolithic, 12 slots, 6 U8 1 Complete AC/DC wiring9 1 5 U 84 HP hinged rear panel10 1 Horizontal mounting space for 3 x 6 U / 4 HP reartransition modules on the rear side11 1 AC power input connector IEC 320 and filter12 1 Blank panel 6 U, 36 HP10002056Order InformationHeightNumber of Width Depth Order No.slotsU HP mm7 (½+6+½)12 84 355 20836-716Note Other backplanes and power supplies available on requestFor further information www.schroff.biz/oneClickoneClick code = Article number10002057For further information ... www.schroff.bizUK 08/20036.5


Systems – VME bus8 U (1+6+1) subrack system with 21-slotbackplaneVME bus Shielded 19" subrack VME system backplane J1/J2 monolithic, 21 slots, 6 U Open Frame power supply with 600 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarm10002005Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with closed cover and base aswell as front handles (RAL 7016)2 1 Open Frame power supply 600 W with wide rangeinput 100 – 240 V (5 V/100 A, 12 V/8 A, -12 V/6 A)3a 1 Display module3b 1 Power switch4 3 Speed-controlled fans for cooling of the boardsmounted on the hinged rear panel (6 U)5 1 FCM module for fan monitoring/control6 1 Mounting space for installation of max. 21 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME system backplane J1/J2 monolithic, 21 slots, 6 U8 1 Complete AC/DC wiring9 1 6 U/84 HP hinged rear panel10 1 Horizontal mounting space for 3 x 6 U / 4 HP reartransition modules on the rear side11 1 AC power input connector IEC 320 and filter10002058Order InformationHeight Number of Width Depth Order No.slotsU HP mm8 (1+6+1) 21 84 355 20836-815Note Other backplanes and power supplies available on requestFor further information www.schroff.biz/oneClickClickoneClick code = Article number100020596.6UK 08/2003For further information ... www.schroff.biz


Systems – VME64x bus4 U subrack system with 8-slot backplaneVME64x bus Shielded 19" subrack for horizontal board mounting with rearI/O (IEC 60297-3-101, -102, -103; IEEE 1101.1, 1101.10/11) VME64x system backplane, 8 slots, 6 U, without P0 connector,horizontally mounted Open Frame power supply with 400 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarm10002006Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack with rear I/O, shielded, with perforatedpanels as well as front handles (RAL 7016)2 1 Open Frame power supply 400 W with wide rangeinput 100 – 240 V (with 4 voltage: 3.3 V/35 A,5 V 60 A, 12 V/10 A, -12 V/6 A)3 1 Vented front panel, 4 U, with display module andmains switch4 1 Speed-controlled fan for cooling of the boards5 1 FCM module for fan monitoring/control6 1 Mounting space for installation of max. 8 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME64x system backplane, 8 slots, 6 U, without P08 1 Complete AC/DC wiring9 1 AC power input connector IEC 320 and filter fitted inrear panel10002052Order InformationHeight Number of Width Depth Order no.slotsU HP mm4 8 84 277.5 20836-416Note VME64x backplanes with other slot numbers or version with P0connector available on request Power supplies with other power ratings available on requestFor further information www.schroff.biz/oneClickoneClick code = Order no.10002053For further information ... www.schroff.bizUK 08/20036.7


Systems – VME64x bus7 U (1/2+6+1/2) subrack system with 12-slotbackplaneVME64x bus Shielded 19" subrack (IEC 60297-3-101, -102, -103;IEEE 1101.1, 1101.10) VME64x system backplane, 12 slots, 6 U, without P0 connector Open Frame power supply with 600 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarm1000200710002056Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with closed cover and base aswell as front handles (RAL 7016)2 1 Open Frame power supply 600 W with wide rangeinput 100 – 240 V (with 4 voltages: 3.3 V/60 A,5 V 60 A, 12 V/10 A, -12 V/5 A)3a 1 Display module3b 1 Power switch4 3 Speed-controlled fans for cooling of the boardsmounted on the hinged rear panel (5 U)5 1 FCM module for fan monitoring/control6 1 Mounting space for installation of max. 12 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME64x backplane, 12 slots, 6 U, without P0connector8 1 Complete AC/DC wiring9 1 Hinged rear panel, 5 U 84 HP10 1 Horizontal mounting space for 3 x 6 U, 4 HP reartransition modules on the rear side11 1 AC power input connector IEC 320 and filter12 1 Blank panel 6 U, 36 HPOrder InformationHeight Number of Width Depth Order no.slotsU HP mm7 (½+6+½)12 84 355 20836-717Note VME64x backplane with other slot numbers or version with P0connector available on request Power supplies with other power ratings available on request10002057For further information www.schroff.biz/oneClickoneClick code = Order no.6.8UK 08/2003For further information ... www.schroff.biz


Systems – VME64x bus10 U (2+6+2) subrack system with 21-slotbackplaneVME64x bus Shielded 19" subrack with rear I/O(IEC 60297-101, -102, -103; IEEE 1101.1, 1101.10/11) VME64x system backplane, 21 slots, 6 U +1 U Open Frame power supply with 1000 W, wide range input andPFC Active heat dissipation of the power supply and boards Display module with DC operating voltages and fan alarm1000201010001003Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack with rear I/O, shielded, with closed coverand base, (front handles RAL 9005 19" bracket, frontpanels RAL 9006)2 1 Open Frame power supply 1000 W with wide rangeinput 100 – 240 V (with 4 voltage: +3.3 V/60 A,+5 V/120 A, +12 V/17 A, -12 V/17 A)3 1 Display module and mains switch4 2 Speed-controlled fans (each with 500 m³/h) for coolingof the boards, mounted behind hinged front panel(2 U) at top5 1 CCM module for fan monitoring/control6 1 Mounting space for installation of max. 21 boards 6 U160 mm deep. Guide rails including ESD clips (ESDclips mounted at front bottom)7 1 VME64x system backplane, 21 slots, 6 U + 1 U8 1 Complete AC/DC wiring9 1 Hinged air inlet front panel with honeycombperforation (2 U)10 1 Mounting space for installation of max. 21 rear I/0boards 6 U, 80 mm deep. Guide rails including ESDclips (ESD clips mounted at front bottom)11 1 AC power input connector IEC 320, fuse and filterOrder InformationHeight Number of Width Depth Order No.slotsU HP mm10 (2+6+2) 21 84 456.5 20836-200Note 1 U drive unit compartment for assembly beneath the system -please order separately1HE = 1U10002060For further information www.schroff.biz/oneClickoneClick code = Article numberFor further information ... www.schroff.bizUK 08/20036.9


Systems – VME64x busDrive unit compartment 1 UVME64x bus For installation of 1 x CD-ROM drive 5 1/4" For installation of 2 x floppy disk drives 3 1/2" For installation of 3 x hard disks 3 1/2"Delivery comprisesItem Qty Description1 1 1-U drive unit compartment (width 449 mm, height44.45 mm, depth 451.5 mm), AIZn steel, front paintedin RAL 90062 1 Assembly kitOrder Information10000007Height Width Depth Order No.U HP mm1 84 451.5 20836-210For further information www.schroff.biz/oneClickoneClick code = Article number6.10UK 08/2003For further information ... www.schroff.biz


Systems – VME64x busFor further information ... www.schroff.bizUK 08/20036.11


Systems – CompactPCISubrack system 1 U with rear I/OCompactPCI System for horizontally mounted board format 6 U, 160 mmdeep (front) and rear I/O boards, 6 U / 80 mm deep(IEC 60297-3-101, -102, -103; IEEE 1101.1, 1101.10/11) Backplane rev. 3.0, 2 slots, 6 U, horizontally mounted, 64-bit ATX power supply 250 W with wide range input and PFC (PowerFactor Correction) Force cooled power supply Heat dissipation of boards by means of fans12302012Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, (depth 275 mm)2 1 ATX PSU 250 W with wide range input 100 – 240 V ACwith IEC connector and mains switch (+3.3 V/20 A,+5 V/21 A, +12 V/13 A, -12 V/0.8 A)3 1 Mounting space for 2 horizontal boards, 6 U / 160 mmdeep, with IEEE guide rails including ESD clipsmounted at front bottom4 3 Fan for cooling the system5 1 Backplane rev. 3.0, 2 slots, 6 U, horizontally mounted,64-bit, system slot on the left6 1 Wiring harness for connection ATX-PSU withbackplane7 1 Mounting space for horizontal rear I/O boards(80 mm), 6 U / 2 slots, with IEEE guide rails includingESD clips fitted at front12302056Order InformationHeight Width Depth Order no.U HP mm1 84 275 24579-024Note Mounting hardware for hard disk or SlimLine CD-ROM availableon requestFor further information www.schroff.biz/oneClickz/oneClickoneClick code = Order no.6.12UK 08/2003For further information ... www.schroff.biz


Systems – CompactPCISubrack system 3 U with rear I/OCompactPCI System for board format 3 U,160 mm deep (front) and rear I/Oboards 3 U / 80 mm deep (IEC 60297-3-101, -102, -103;IEEE 1101.1, 1101.10/11) Backplane rev. 3.0, 8 slots, 3 U, 32-bit, system slot on the right (ATX) power supply 300 W and wide range input and PFC(Power Factor Correction) Heat dissipation of the power supply by means of fan Heat dissipation of boards by means of convection cooling1230200212302050Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with perforated cover and baseas well as front handles, (depth 275 mm)2 1 (ATX) PSU 300 W with wide range input 100–240 V ACIEC connector and mains switch, mounted at front(32 HP) (+3.3 V/28 A, +5 V/30 A,12 V/15 A, -12 V/0.8 A)3 1 Blank panel 3 U / 8 HP for hard disk4 1 Drive unit 3 U / 8 HP, mounting space for 3.5" floppy5 1 Mounting space for vertical boards 3 U / 8 slots(32 HP) for 160 mm deep boards, with IEEE guiderails including ESD clips mounted at front bottom6 1 Blank panel 3 U / 4 HP7 1 Backplane rev. 3.0, 8 slots, 3 U, 32-bit, system slot onthe right8 1 Wiring harness for connection ATX-PSU withbackplane9 1 Blank panel 3 U / 4 HP mounted to rear10 1 Mounting space (32 HP) for rear I/O boards (80 mm),3 U, with IEEE guide rails including ESD clips fitted atbottom11 1 Blank panel 3 U / 48 HP mounted at rearOrder InformationHeight Width Depth Order no.U HP mm3 84 275 24579-031 If items 3+4 are not used, installation of an additional backplaneis possible. See chapter 'Backplanes - compactPCI bridge'For further information www.schroff.biz/oneClickoneClick code = Order no.For further information ... www.schroff.bizUK 08/20036.13


Systems – CompactPCISubrack system 4 U with rear I/OCompactPCI System for horizontally mounted board format 6 U, 160 mmdeep (front) and rear I/O boards 6 U, 80 mm deep(IEC 60297-3-101, -102, -103; IEEE 1101.1, 1101.10/11) Backplane rev. 3.0, 4 slots, 6 U, horizontally mounted, 64-bit,system slot on the right (ATX) power supply 300 W and wide range input and PFC(Power Factor Correction) Heat dissipation of the power supply by means of fan Heat dissipation of boards by means of a fanDelivery comprises (completely assembled and wired)1230200312302051Item Qty Description1 1 19" subrack, shielded, with perforated side panel aswell as front handles, (depth 275 mm)2 1 (ATX) PSU 300 W with wide range input 100 –240 V AC IEC connector and mains switch, fitted atrear (+3.3 V/28 A, +5 V/30 A, +12 V/15 A, -12 V/0.8 A)3 1 Vented front panel, 4 U, with mounting space forSlimLine CD-ROM drive4 1 Fan for cooling of boards5 1 Mounting space for horizontal boards, 6 U / 4 slots, for160 mm deep boards, with IEEE guide rails includingESD clips mounted at front bottom6 4 Blank panel 6 U / 4 HP7 1 Backplane rev. 3.0, 4 slots, 6 U, horizontally mounted,64-bit, system slot on the right8 1 Wiring harness for connection ATX-PSU withbackplane9 4 Blank panel 6 U / 4 HP mounted at rear10 1 Mounting space for rear I/O boards (80 mm), 6 U /4 slots, with IEEE guide rails including ESD clips fittedat frontOrder InformationHeight Width Depth Order no.U HP mm4 84 275 24579-029 If item 6 is not used, installation of an additional backplane ispossible. See chapter 'Backplanes - compact PCI bridge'For further information www.schroff.biz/oneClickoneClick code = Order no.6.14UK 08/2003For further information ... www.schroff.biz


Systems – CompactPCISubrack system 5 U with rear I/OCompactPCI System for horizontally mounted board format 6 U, 160 mmdeep (front) and rear I/O boards 6 U, 80 mm deep(IEC 60297-3-101, -102, -103; IEEE 1101.1, 1101.10/11) Backplane rev. 3.0, 8 slots, 6 U, horizontally mounted, 64-bit,system slot on the right (ATX) power supply 300 W and wide range input and PFC(Power Factor Correction) Heat dissipation of the power supply by means of a fan Heat dissipation of boards by means of fans1230201412302052Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with perforated side panel aswell as front handles, (depth 275 mm)2 1 (ATX) PSU 300 W with wide range input 100 –240 V AC IEC connector and mains switch(+3.3 V/ 28 A, +5 V/30 A, +12 V/15 A, -12 V/0.8 A)3 1 Vented front panel, 5 U, with mounting space forSlimLine CD-ROM drive4 2 Fans for cooling of boards5 1 Mounting space for boards 6 U / 8 slots 160 mm deepboards, with IEEE guide rails including ESD clipsmounted at front bottom6 2 Blank panel 6 U / 4 HP7 1 Backplane rev. 3.0, 8 slots, 6 U, horizontally mounted,64-bit, system slot on the right8 1 Wiring harness for connection ATX-PSU withbackplane9 2 Blank panel 6 U / 4 HP mounted at rear10 1 Mounting space for rear I/O boards (80 mm), 6 U /8 slots, with IEEE guide rails ESD clips fitted at frontOrder InformationHeight Width Depth Order no.U HP mm5 84 275 24579-025For further information www.schroff.biz/oneClickoneClick code = Order no.For further information ... www.schroff.bizUK 08/20036.15


Systems – CompactPCISubrack system 6 U with rear I/OCompactPCI System for board format 6 U,160 mm deep (front) and rear I/O6 U / 80 mm deep (IEC 60297-3-101, -102, -103;IEEE 1101.1, 1101.10/11) Backplane rev. 3.0, 8 slots, 6 U, 64-bit, system slot on the right (ATX) power supply 300 W and wide range input and PFC(Power Factor Correction) Heat dissipation of the power supply by means of a fan Heat dissipation of boards by means of convection cooling1230200412302053Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with perforated cover and baseas well as front handles, (depth 275 mm)2 1 (ATX) PSU 300 W with wide range input 100 - 240 V ACIEC connector and mains switch, drive on front left(32 HP) (+3.3 V/28 A, +5 V/30 A, +12 V/15 A,-12 V/0.8 A)3 1 Blank panel 6 U, 16 HP4 1 Mounting space for 3.5" floppy and 5.25" CD-ROM5 1 Mounting space for boards 6 U / 8 slots (32 HP) for160 mm deep boards, with IEEE guide rails includingESD clips mounted at front bottom6 1 Blank panel 6 U / 4 HP7 1 Backplane rev. 3.0, 8 slots, 6 U, 64-bit, system slot onthe right8 1 Wiring harness for connection ATX-PSU withbackplane9 1 Blank panel 6 U / 4 HP mounted at rear10 1 Mounting space (32 HP) for rear I/O boards (80 mm),6 U / 8 slots, with IEEE guide rails including ESD clipsfitted at bottom11 1 Blank panel, 6 U / 48 HP, mounted at rearOrder InformationHeight Width Depth Order no.U HP mm6 84 27524579-030 If item 3 is not used, installation of an additional backplane ispossible. See chapter 'Backplanes - compact PCI bridge'For further information www.schroff.biz/oneClickoneClick code = Order no.6.16UK 08/2003For further information ... www.schroff.biz


Systems – CompactPCISubrack system 6 U + 1 U with rear I/OCompactPCI System for board format 6 U,160 mm deep (front) and rear I/O6 U / 80 mm deep (IEC 60297-3-101, -102, -103;IEEE 1101.1, 1101.10/11) Backplane rev. 3.0, 8 slots, 6 U, system slot on the right (ATX) power supply 300 W and wide range input and PFC(Power Factor Correction) Heat dissipation of the power supply by means of a fan Heat dissipation of boards by means of fans in a 1 U hightelescopic tray (Hot Swap)1230201312302054Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with perforated cover and baseas well as front handles, (depth 275 mm)2 1 (ATX) PSU 300 W with wide range input 100 –240 V AC IEC connector and mains switch, mounted atfront (32 HP) (+3.3 V/28 A, +5 V/30 A, +12 V/15 A,-12 V/0.8 A)3 1 Blank panel 6 U, 16 HP4 1 Mounting space for 3.5" floppy and 5.25" CD-ROM5 1 Mounting space for boards 6 U / 8 slots (32 HP) for160 mm deep boards, with IEEE guide rails includingESD clips mounted at front bottom6 1 Blank panel 6 U / 4 HP7 1 Backplane rev. 3.0, 8 slots, 6 U, system slot on theright8 1 Wiring harness for connection ATX-PSU withbackplane9 1 Blank panel 6 U / 4 HP mounted at rear10 1 Mounting space for boards (32 HP) for rear I/O boards(80 mm), 6 U / 8 slots, with IEEE guide rail includingESD clip fitted at bottom11 1 Blank panel, 6 U / 48 HP, mounted at rear12 1 Telescopic fan tray, 1 U with 1 × 12 V DC fanOrder InformationHeight Width Depth Order no.U HP mm7 84 275 24579-026Note Filter mat on request If item 3 is not used, installation of an additional backplane ispossible. See chapter 'Backplanes - compact PCI bridge' Other DC fans, see chapter 'Climate control accessories'For further information www.schroff.biz/oneClickz/oneClickoneClick code = Order no.For further information ... www.schroff.bizUK 08/20036.17


Systems – CompactPCISubrack system for telecom applications 6 U +4 U with rear I/OCompactPCI System with PSB backplane (PSB = Packet SwitchedBackplane) complying with PICMG 2.16, with 14 node slots and2 fabric slot (IEC 60297-3-101, -102, -103;IEEE 1101.1, 1101.10/11) Board format 6 U,160 mm deep (front) and rearI/O boards 6 U, 80 mm deep 19" PSU 250 Watts and PFC (Power Factor Correction) Heat dissipation of the power supply by means of fans(with monitoring module)1230200512302055Delivery comprises (completely assembled and wired)Item Qty Description1 1 19" subrack, shielded, with front handles (RAL 9005),air inlet panel, 19" bracket and air outlet in RAL 9006,remaining parts in aluminium, colourless, chromated,(depth 275 mm)2 2 19" PSU 250 W with wide range input 100 – 240 V ACwith Positronic connector P47, (8 HP) (+3.3 V/40 A,+5 V/40 A, +12 V/5.5 A, -12 V/1.5 A), mounting spacefor 2 additional PSUs3 2 Blank panels 3 U / 8 HP to cover the mounting spacefor additional19" PSUs4 2 Blank panel 3 U / 4 HP to cover the mounting space forCMM modules (Chassis Monitoring Module) to beordered separately5 1 Mounting space for boards 6 U 2/14 slots for 160 mmdeep boards, with IEEE guide rail including ESD clipmounted at front bottom6 1 Air inlet panel with hexagonal honeycomb perforation,hinged, telescopic fan drawer with 3 fans 24 V DC ,260 m/h, as well as filter7 1 PSB backplane PICMG 2.16, 2/14 slots, 6 U, 64-bit(Packet Switched Backplane)8 1 Wiring harness for connection of power supply withbackplane9 1 Rear power input module, 6 U / 8 HP, with IECconnector and filter, 100–240 V AC10 1 Blank panel 6 U / 8 HP, mounted on rearOrder InformationHeight Width Depth Order no.U HP mm10 84 275 24579-028 Chassis Monitoring Module (CMM), see 'Accessories' Compact PCI power supplies, 19" compatible, see chapter'Power supplies'For further information www.schroff.biz/oneClickoneClick code = Order no.6.18UK 08/2003For further information ... www.schroff.biz


Systems – CompactPCIAir flow barrierCompactPCI To cover slots not required in CompactPCI systems Cover is pushed into the IEEE guide railDelivery comprisesItem Qty Description1 1 Air flow barrier, aluminium, 1 mmOrder Information06101507Height Width Depth Order no.U HP mm3 4 160 34562-8233 4 220 34562-8243 8 160 34562-8333 8 220 34562-8343 12 160 34562-8433 12 220 34562-8446 4 160 34562-8266 4 220 34562-8276 8 160 34562-8366 8 220 34562-8376 12 160 34562-8466 12 220 34562-847Note 280 mm slot filler panel available on requestFor further information www.schroff.biz/oneClickoneClick code = Order no.06101506For further information ... www.schroff.bizUK 08/20036.19


Systems – CompactPCIU-profile panel for 3 U rear I/OCompactPCI Rear I/O cover for 3 U 32-bit compact PCI systems Use with IEL and IET handlesOrder InformationHeight Width b Type Qty Order no.U HP mm3 4 19.98U-profile panel,aluminium front anodised, 1 30848-867rear side chromated3 8 40.3U-profile panel,aluminium front anodised, 1 30848-869rear side chromated3 12 60.64U-profile panel,aluminium front anodised, 1 30848-985rear side chromatedEMC profile seal , 10 pieces 21101-853EMC profile seal ,100 pieces 21101-85404602050Note Rear I/O panels for offset available on request Other front profiles, see chapter 'Assemblies - Front panels' IEEE handles, see chapter 'Assemblies - Plug-in units' Assembly kit, see chapter 'Assemblies - assembly kit'For further information www.schroff.biz/oneClickoneClick code = Order no.Circuit board covers (solder side covers) Versions available on request:– 3 U / 160 T– 6 U / 160 T– 6 U / 80 T Covers made of clear antistatic plastic UL-94-V-06.20UK 08/2003For further information ... www.schroff.biz


Systems – CompactPCIFor further information ... www.schroff.bizUK 08/20036.21


Overview ................. 0Systems – Advanced TCACabinets.................. 1Climate Control....... 2Cases ...................... 3Subracks/19" chassis............. 4Modules .................. 512703001Systems .................. 6Power supplyunits........................ 7ATCA Backplanes Full Mesh06800005ATCA Front Panel According to PICMG 3.0 Rev 1.012703004Backplanes ............. 8 Backward compatible Dual StarAccessories ............ 9Appendix............... 102.16 Adaptor for ATCA For adaptation of CPCI 2.16 boards in ATCA systems12703002 12703003Cost effective 2-slot ATCA Development System With integrated 48 V DC power supplyand wide range input With easy access to boards for test purposesFurther important information can be found on the internetunder www.a-tca.com6.22 UK 08/2003For further information .... www.schroff.biz


Systems – Advanced TCAOverview ........... 6.22PICMG 3.0 – AdvancedTCAThe Advanced Telecom Computing Architecturespecification was originally tailored specifically to thetelecom market, but high performance networkingproducts can also be built with this platform.ATCA is designed to provide an efficient solution forhigh-power systems and allows central offices toreplace proprietary systems.A new form factor has been defined with a board heightof 8 U, a front board depth of 280 mm and a rear I/Oboard (RTM) depth of 70 mm. The front panel width is6 HP with the board offset by 0.1". The offset providesmore room for SMT components on the rear of theboard. Repositioning of the EMC gasket to the left sideof the front panel lowers the risk of component damageduring the extraction of the boards.The new handle has been optimized for high insertionand extraction forces.When a Dual Star backplane is used, two Fabric andtwelve Node Boards can be used in an ATCA chassisdesigned to fit into a 19" cabinet. With a Full Meshbackplane 14 Node Boards can be used. Otherbackplane architectures can be built such as Dual-DualStar and Replicated-Mesh. The ATCA specificationalso allows 16 slot systems to be built that fit into 23"telecom or 600 mm ETSI cabinets.ATCA systems are designed for a maximum powerdissipation of 200 W per board. A 14 slot ATCA chassiscan dissipate up to 2.8 kW.The overall data transfer rate of the system depends onthe fabric layer, protocol, and fabric architecture usedand can reach more than 1 Tb/s. So far Ethernet(PICMG 3.1), Infiniband (PICMG 3.2) and StarFabric(PICMG 3.3) fabric layers have been defined. The PCIExpress (PICMG 3.4) specification is being written.The connectors in an ATCA system are categorized intothree different groups, Zones 1 through 3. The Zone 1 connector provides power, primary(IPMI) system management, and the board'sgeographic address.The Zone 2 connectors have both a 10/100/1000BASE-T Base Interface and a Fabric Interfacedefined. The Base Interface is used for transferringFLASH memory images, loading firmware, and highlevel management functions. The Fabric Interface isused to transfer large amounts of data at high speeds The Zone 3 connectors are determined by theindividual application. The 70 mm deep RTM(Rear Transition Module) connects directly to thefront board. This allows either metallic or fiberconnectors to be used between the front board andthe RTMAn efficient management system with electronickeying is responsible for monitoring and powering upthe boards, enabling the fabric ports, thermalmanagement, remote maintenance and softwareupdates.For further information .... www.schroff.bizUK 08/20036.23


Systems – AccessoriesFan Control Module (FCM)Accessories Monitoring and temperature-dependent control of fan speed(µC-controlled) Up to 4 fans and 4 temperature sensors (NTC) can beconnected Warning in the case of a malfunction (fan, sensor, µC,over-temperature), increase in fan speed to maximum value Optional display of DC voltages, "Fan Fail" and "Over Temp" viaLED Remote monitoring in conjunction with Schroff ChassisMonitoring Module (CMM)Delivery comprisesSpeed characteristic curve12102002Item Qty Description1 1 Fan Control Module (FCM),width 38 mm, depth 160 mm, height 28 mm2 1 Temperature sensor3 1 Set of mating connectorsOrder InformationDescription Height Width Depth Order No.mm mm mmFan Control Module (FCM) 28 38 160 23207-021For further information www.schroff.biz/oneClickoneClick code = Article numberBlock diagram, inputs / outputs09802053098020526.24UK 08/2003For further information ... www.schroff.biz


Systems – AccessoriesChassis Monitoring Module (CMM)Accessories Monitoring voltages, temperatures and digital inputs Communication and remote monitoring via RS 232 or Ethernetinterface (-10BaseT) Inputs and outputs for VME- and CPCI-specific signals, otherdigital and LED outputs Data for communication with the Schroff Fan Control Module(FCM) Pluggable in the 3 U euroboard formatStatus display via Web browser12303001Delivery comprisesItem Qty Description1 1 Chassis Monitoring Module (CMM),height 3 U, depth 160 mm, width 4 HP,front panel mountedOrder InformationDescription Height Depth Order No.U mmChassis Monitoring Module (CMM) 3 160 23207-022For further information www.schroff.biz/oneClick/oneClickoneClick code = Article numberBlock diagram, inputs / outputs09802051+5Vpower inputNTC[1..7]SYSFAIL(VME)AC-fail[1..2] (VME)PSU-fail[1..4] (CPCI)PSU derating[1..4] (CPCI)υShelf Address[A0..A4] (CPCI)+5V monitor in+3.3V monitor in+12V monitor in-12Vmonitor in+24V monitor in-24Vmonitor inChassisMonitoringModule(CMM)TTL-output [1..4]Opto coupler output [1..4]SYSRESET (VME)DEG (CPCI) / AC-Fail (VME)FAL (CPCI)RS232 (front panel)RS485Ethernet 10BaseT, (front panel)Data Bus to Fan ControlModule (FCM)Over Temp LED redFan Fail LED redVoltage ok/fail + 5V LED red/greenVoltage ok/fail +3.3V LED red/greenVoltage ok/fail +12V LED red/greenVoltage ok/fail –12V LED red/green09802050For further information ... www.schroff.bizUK 08/20036.25


Systems – AccessoriesSide panels, cover plates, horizontal rails,guide rails Mechanical items such as side panels, horizontal rails, IEEEguide rails or cover plates, see 'Accessories for europacPROsubracks'06100001 06102003Front panels,IEEE handles Shielded front panels and IEEE handles, see 'Accessories,assemblies' Customer-specific modified front panels, refer to Internet FrontPanel Express04292001 04602005Drive units Drive units, see 'Assemblies, drive units'04995002Backplanes/bridges Compact PCI backplanes, bridges and accessories, seechapter 'Backplanes' VME bus, VME64x backplanes and accessories, see chapter'Backplanes'12401001 124010046.26UK 08/2003For further information ... www.schroff.biz


Systems – AccessoriesPower supplies Compact PCI power supplies and accessories, see chapter'Power supplies' VME bus, VME64x power supplies and accessories, seechapter 'Power supplies'11302005 12302007DC fans/fan insertDC fans/fan insert, see chapter ’Climate Control’12398008For further information ... www.schroff.bizUK 08/20036.27