QM1A3– Single DeckApplication:9CASE DATA 04A 06A 08A 12AAnti-Sweat Amps 0.06 0.08 0.12 0.18Fan Amps (SP) 0.34 0.68 0.68 1.02Light Amps N/A N/A N/A N/ADefrost Load Amps (If elec-230V) 3.30 5.61 7.93 11.54# Defrosts Required 4 4 4 4Evaporator Temperature °F +24° +24° +24° +24°BTU Requirements 2000 3000 4000 6000NOTE: For sizing conventional/individual condensing units ADD 8% to BTU LOAD.Defrost Per Day Fail Safe TerminationOff Cycle 4 35 min 48°Hot gas 4 18 min 48°Electric 4 35 min 48°Discharge Air Velocity150 FPMDischarge Air Temp 27°FType I refrigerator, intended for use in an area where the environmental conditionsare controlled and maintained such that conditions do not exceed 75 deg Fand 55% relative humidity. <strong>Kysor</strong>//<strong>Warren</strong>, whose policy is one of continuousimprovement, reserves the right to change at any time, specifications, design orprices without incurring obligation.Dual-Jet and Air Defrost are registered trademarks of <strong>Kysor</strong>//<strong>Warren</strong>.The above case model, has case lengths thatare UL and NSF approved.Issue: Sept - 06