11.07.2015 Views

PLT unit - t Labo

PLT unit - t Labo

PLT unit - t Labo

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Main MenuA wide variety of submenuscan be selected from themain menu, e.g., pipette type,volume range, self-test, andsettings (language, shut-offtime, pressure <strong>unit</strong>s, etc.)Main MenuPipette TypeSelf TestSwitch OFFSettings...Auswahl selectzurück backTesting with and without tipTo check the overall pipette system,the test is conducted withmounted, unused tip.When a leak has been identified,the test can be repeated withouta tip to determine whether theleak arises from the tip cone/tipcoupling region.Dynamic or static test?The dynamic test can rapidlydetermine whether a defectivepiston (contamination,scratches, etc.) has caused aleak. The pipette button mustbe pushed down numeroustimes during the measurementperiod. The associated pistonmovement allows a defectivepiston to be recognized.In the static test, the pipettebutton is not pressed duringthe test procedure, i.e. the pistondoesn't move. This will onlydetermine a leak in a generalway, without attributing it to aparticular component.Limit valuesThe limit values referenced duringtesting represent a warninglimit, from which significantlylower volume values can alsobe determined gravimetrically.This is one quarter of the volumetolerances, according toISO 8655-2.The limit value for the leak volumeof a given pipette allowsthe leak rate to be calculated.These calculations, which arebased on over 35 years ofexperience in the developmentand production of pipettes, includethe dead volume and theintake characteristics, amongother things.If the pipette is mechanicallydefect-free, clean, and thetest is carried out properlywith the BRAND <strong>PLT</strong> <strong>unit</strong>,then the instrument is withinthe ISO 8655-2 tolerances.The marks in the verticalprogress bars in the displaystartstartPASSWith the correlation table inthe <strong>PLT</strong> operating manual,the pipette is leak-tight, andSC – 100 µlwhether itQ L: 0.04 hPa lies within thetolerance limits or leaks.* ml/srepresent the resident limitvalues for the leak rate Q L .PASSSC – 100 µlQ L: 0.04 hPa* ml/sthe missing volume can beapproximately determinedfrom the leak rate. The levelof the progress bar in thedisplay indicates whetherFAILSC – 100 µlQ L: 4.6 hPa* ml/sstart

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!