<strong>SIMOVERT</strong> <strong>MV</strong>Engineering informationSystem componentsTransformersThe <strong>SIMOVERT</strong> <strong>MV</strong> drive converteris connected <strong>to</strong> the medium-voltagesystem via a driveconverter transformer. Thestandard12-pulse DFE requires a threewindingtransformer, theoptional 24-pulse DFE twothree-winding transformers orone five-winding transformer.When the transformer is implemented,the <strong>SIMOVERT</strong> <strong>MV</strong>drive (converter and mo<strong>to</strong>r) isdecoupled and electrically isolatedfrom the mains supply:¦ The short-circuit power isthus reduced <strong>to</strong> a valuesmaller than max. permissible¦ The mo<strong>to</strong>r is operatedground-free¦ Low harmonic dis<strong>to</strong>rtionthrough 12-pulse DFE.An insulation moni<strong>to</strong>ring devicein the drive converter moni<strong>to</strong>rsthe insulation status betweensecondary transformer windingand mo<strong>to</strong>r.Three-winding transformerThe secondary windings ofthe three-winding transformerhave a phase angle of 30 ° el.,resulting in 12-pulse infeedcombined with lower harmonicdis<strong>to</strong>rtion.Apart from electrical and thermalstress during converter-fedoperation, also the followingproperties have <strong>to</strong> be taken in<strong>to</strong>account when engineering thetransformer:¦ Impedance voltage V k :6% min.¦ Tappings for voltageadjustments:2 x ± 2.5% or ± 5% for operationwith output filter. Thewinding tappings are usuallylocated on the HV-side of thetransformer.¦ The secondary-side insulationvoltage is <strong>to</strong> be dimensionedfor the test voltagestated in the table on thefollowing page. The impulsestrength test voltage forreinforced insulation isspecified 1 ).Three-winding transformersfor drive converters withpower section in parallelcircuitThe infeed on the line side canbe carried out via a shared12-pulse transformer circuitfor both partial systems (seeFig. 6/12). Infeed is also possiblevia two separate 12-pulsetransformers (see Fig. 6/13).A 24-pulse supply can also beestablished by shifting the twotransformer phases through ±7.5 °.With the shared 12-pulse transformercircuit, commutatingreac<strong>to</strong>rs with V k W 2% mustbe used in the correspondingrectifier cable. If there is enoughspace, the reac<strong>to</strong>rs must befitted close <strong>to</strong> the transformer 2 ).Transformer secondary voltages and associated insulation requirementsRated voltage 2.3 kV; 3.3 kV; 4.16 kV; 6 kV; 6.6 kV 2 x 4.16 kV (with power section connected in parallel)Infeed 12-pulse 24-pulse 12-pulse 12- or 24-pulseInfeed viaPrinciple diagram1 Three-windingtransformer2 Three-windingtransformers 3 )1 Three-winding transformerand commutatingreac<strong>to</strong>rs(see Fig 6/12)2 Three-windingtransformers 3 )(see Fig 6/13)Recommendedvec<strong>to</strong>r groupConverterratedvoltagekVConverterratedpower<strong>kVA</strong>Dy5 Dd0Transformersecondaryvoltage4 )kVDy5 Dd0 +7.5 ° phase shiftDy5 Dd0 –7.5 ° phase shiftTransformersecondaryvoltage4 )kVDy5 Dd0Transformersecondaryvoltage4 )kVDy5 Dd0 (if required +7.5° phase shift)Dy5 Dd0 (if required –7.5 ° phase shift)Transformersecondaryvoltage4 )kVImpulse str. testvoltage:secondarywinding <strong>to</strong> earth 1 )62.3 800 – 2600 2 x 1.2 2 x 0.6 (2x) – – 23.6 kV3.3 1000 – 4000 2 x 1.7 2 x 0.85 (2x) – – 33.6 kV4.16 1300 – 5000 2 x 2.2 2 x 1.1 (2x) – – 38.9 kV2 x 4.16 4700 – <strong>9100</strong> – – 2 x 2.2 2 x 2.2 (2x) 38.9 kV6.0/6.6 <strong>660</strong> – 2000 2 x 1.2 2 x 0.6 (2x) – – 53.0 kVPlease note:Transformers and commutating reac<strong>to</strong>rs are notincluded in the converter scope of supply!1) The voltages stated are the necessary test voltages <strong>to</strong> earth for thetransformer secondary windings. As the transformer windings usuallyincorporate temperature evaluation circuits, test voltages for reinforcedinsulation must be applied. If there are no control circuits in the windings,test voltages for basic insulation are sufficient.2) Please note: Transformers and commutating reac<strong>to</strong>rs are not included inthe converter scope of supply!3) Instead of the two three-winding transformers one five-windingtransformer can be used (<strong>to</strong> be clarified with the transformermanufacturer).4) No-load voltageSiemens DA 63 · 2004 6/17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!