11.07.2015 Views

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SIMOVERT MV Medium-Voltage Drives 660 kVA to 9100 ... - Industry

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Mo<strong>to</strong>rs<strong>SIMOVERT</strong> <strong>MV</strong>H-compact PLUSmodular high-voltage mo<strong>to</strong>rsSelection and ordering data · 1RA4 open-circuit ventilated mo<strong>to</strong>rs, 1RN4 air-<strong>to</strong>-water cooled mo<strong>to</strong>rs ·Pump and fan drives (M ~ n 2 )Rated Shaft Order No. Operating data at rated output Starting Starting Stall Momen<strong>to</strong>utput height Rated Effi- Power Power Rated Rated <strong>to</strong>rque current <strong>to</strong>rque of inertiaspeed ciency fac<strong>to</strong>r loss current <strong>to</strong>rqueDirect online startingP N n N η cos ϕ 1 P V I N M N M A /M N I A /I N M K /M N JkW rpm % kW A Nm kgm 242.3 kV 50 Hz, temperature class F, utilization according <strong>to</strong> F1500 rpm, 4-pole1520 450 1R@4450-4HV0@ 1480 96.2 0.89 60.0 445 9807 0.65 4.8 2.0 211700 450 1R@4452-4HV0@ 1482 96.3 0.89 65.3 500 10954 0.70 5.1 2.0 231920 450 1R@4454-4HV0@ 1482 96.4 0.89 71.7 560 12372 0.60 4.8 1.9 262180 450 1R@4456-4HV0@ 1483 96.6 0.89 76.7 640 14037 0.65 5.1 2.0 2<strong>9100</strong>0 rpm, 6-pole1100 450 1R@4450-6HV0@ 985 95.3 0.85 54.2 340 10664 0.75 4.6 1.9 291240 450 1R@4452-6HV0@ 986 95.6 0.85 57.1 385 12009 0.75 4.7 1.9 331440 450 1R@4454-6HV0@ 985 95.6 0.87 66.3 435 13960 0.75 4.6 1.8 361700 450 1R@4456-6HV0@ 986 95.9 0.87 72.7 510 16464 0.75 4.8 1.9 411960 500 1R@4500-6HV0@ 988 95.9 0.86 83.8 600 18944 0.75 4.9 1.9 572200 500 1R@4502-6HV0@ 988 96.1 0.87 89.3 <strong>660</strong> 21264 0.75 4.8 1.9 65750 rpm, 8-pole860 450 1R@4450-8HV0@ 740 94.9 0.84 46.2 270 11098 0.85 5.0 2.0 37960 450 1R@4452-8HV0@ 740 95.3 0.84 47.3 300 12388 0.85 5.0 2.0 411080 450 1R@4454-8HV0@ 741 95.4 0.83 52.1 340 13918 0.80 5.1 2.0 461220 450 1R@4456-8HV0@ 741 95.5 0.83 57.5 385 15722 0.80 5.1 2.0 521440 500 1R@4500-8HV0@ 741 95.6 0.83 66.3 455 18557 0.75 4.8 1.9 701600 500 1R@4502-8HV0@ 742 95.8 0.83 70.1 510 20591 0.80 4.9 1.9 801780 500 1R@4504-8HV0@ 742 96.0 0.84 74.2 550 22908 0.80 4.9 1.9 881960 500 1R@4506-8HV0@ 742 96.0 0.84 81.7 610 25225 0.80 4.9 1.9 992.3 kV 60 Hz, temperature class F, utilization according <strong>to</strong> F1800 rpm, 4-pole1740 450 1R@4450-4HV1@ 1781 96.5 0.89 63.1 510 9329 0.65 5.1 2.0 211940 450 1R@4452-4HV1@ 1783 96.6 0.89 68.3 570 10390 0.70 5.5 2.1 232200 450 1R@4454-4HV1@ 1782 96.7 0.89 75.1 640 11789 0.65 5.2 2.0 262500 450 1R@4456-4HV1@ 1784 96.8 0.89 82.6 730 13382 0.65 5.4 2.1 291200 rpm, 6-pole1260 450 1R@4450-6HV1@ 1186 95.7 0.85 56.6 390 10145 0.70 4.7 1.9 291420 450 1R@4452-6HV1@ 1186 96.0 0.85 59.2 435 11433 0.75 4.8 1.9 331640 450 1R@4454-6HV1@ 1186 96.0 0.87 68.3 495 13205 0.70 4.8 1.9 361940 450 1R@4456-6HV1@ 1187 96.3 0.86 74.5 590 15607 0.75 5.0 2.0 412220 500 1R@4500-6HV1@ 1189 96.3 0.86 85.3 670 17830 0.75 5.1 2.0 57900 rpm, 8-pole1000 450 1R@4450-8HV1@ 889 95.3 0.84 49.3 315 10742 0.80 4.9 1.9 371120 450 1R@4452-8HV1@ 890 95.7 0.84 50.3 350 12017 0.85 5.1 2.0 411260 450 1R@4454-8HV1@ 891 95.6 0.83 58.0 400 13504 0.75 5.0 2.0 461420 450 1R@4456-8HV1@ 891 95.7 0.83 63.8 450 15219 0.75 5.0 2.0 521640 500 1R@4500-8HV1@ 891 95.9 0.84 70.1 510 17577 0.75 4.9 1.9 701840 500 1R@4502-8HV1@ 892 96.0 0.84 76.7 570 19698 0.75 4.9 1.9 802020 500 1R@4504-8HV1@ 892 96.2 0.84 79.8 620 21625 0.75 4.9 1.9 882220 500 1R@4506-8HV1@ 892 96.4 0.84 82.9 690 23766 0.80 5.1 2.0 99▲ ▲open-circuit cooling Aair-<strong>to</strong>-water cooling NType of constructionIM B3 0IM V1 without prot. roof assembly 84/40 Siemens DA 63 · 2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!