11.07.2015 Views

PadPuls M2 - Maddalena

PadPuls M2 - Maddalena

PadPuls M2 - Maddalena

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Adaptable:<strong>PadPuls</strong> <strong>M2</strong><strong>PadPuls</strong> <strong>M2</strong><strong>PadPuls</strong> <strong>M2</strong>C<strong>PadPuls</strong> <strong>M2</strong>IM003G<strong>PadPuls</strong> <strong>M2</strong>C005327,6 034780,4M-Bus Port 2 Port 1 Tarif 005327,6m 3 m 3 M M P2+ P2- P1+ P1- N L m 3- BusFunction of the <strong>PadPuls</strong> <strong>M2</strong>(C)The <strong>PadPuls</strong> <strong>M2</strong> adapts up to two impulse meterswith floating output (for example gas, water,electricity meter,...) to the M-Bus system or, in manycases, electronic So outputs as well. Both pulseinputs can individually be configured. <strong>PadPuls</strong> <strong>M2</strong>thus acts as two stand-alone M-Bus slaves.The supply for the impulse counting function is takenfrom the M-Bus. In case of a bus failure an integratedbattery ensures data integrity and count operation.An optional available battery with greater capacityallows M-Bus independent metering for severalyears.Technical dataPower supply:by M-Bus, switches automatically tobattery in case of bus failureBus operation:max. 1.5mA (1 unit load),Battery operation:current taking max 50 ABattery expectancy 0.23Ah: 10 years at max. 18 failure days p.a.(changeable coin-type battery)Battery expectancy 1.35Ah: 10 years at max.110 failure days p.a.Temperature range: 0 .. 55 o CPulse inputs:2, individual adjustableContact voltage: 2.5V .. 3.6VContact current:30 ADebouncing time:5msCable pulse generator: max. 10mOrder information<strong>PadPuls</strong> <strong>M2</strong> (0,23Ah-battery, wall)<strong>PadPuls</strong> <strong>M2</strong> (1,35Ah-battery, wall)<strong>PadPuls</strong> <strong>M2</strong>C (0,23Ah-battery, rail mount.)<strong>PadPuls</strong> <strong>M2</strong>C (1,35Ah-battery, rail mount.)Another feature of the <strong>PadPuls</strong> <strong>M2</strong> is the due-datefunction. Meter data are saved separately at thepreset due-date by the implemented clock withcalendar function. By this, for example, annualconsumption data can be obtained withoutadditional calculation software.The <strong>PadPuls</strong> <strong>M2</strong>C version has the same functionalfeatures as the <strong>M2</strong>, however in addition it has a tariffinput for 230VAC signal (for example from a ripplecontrolreceiver).The <strong>PadPuls</strong> <strong>M2</strong> is delivered in a housing for wallmounting while the <strong>PadPuls</strong> <strong>M2</strong>C housing ismounted on a DIN rail (3TE).Requirements to the contacts of the impulse generators:Potential:floatingResistance:open > 1M , closed < 2kContact duration, pause: min. 30msPulse frequency:max. 14 HzTariff signal:floating (data see above)Or: 100..250VAC (<strong>PadPuls</strong> <strong>M2</strong>C)M-Bus protocol:Transmission rate:Case mounting:Protection type:Dimensions (<strong>M2</strong>):Dimensions (<strong>M2</strong>C):Accessoriesaccording to EN1434-3300, 2400 baud (autom. detection)rail (DIN-EN 50 022) or wall mountingIP40WxHx D: 80 x 80 x 52 mmWxHx D: 93 x 51 x 58 mmDelivery contains:PC-software for 32Bit-Windows for configurationM-Bus readout-software:Look@M-Bus for Windows95/98/NT

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!