2-2 General Information <strong>New</strong> <strong>Functions</strong> <strong>19VRS</strong><br />

Firmware<br />

2.4 Software requirements<br />

Note: Due to the required computing power and free memory space,<br />

the Windows NT version of the <strong>19VRS</strong> software can no<br />

longer be used in the BTV01. There will only be the DOS<br />

version that can be used in the BTV01 under the <strong>19VRS</strong><br />

software.<br />

The firmware of version 19 can be used on the following hardware<br />

platforms:<br />

Hardware type Firmware type<br />

MTC-P01.2-xxx FWA-MTCP01-M01-<strong>19VRS</strong>-NN<br />

MTC-R01.1-xxx<br />

FWA-MTCR0*-M01-<strong>19VRS</strong>-NN<br />

MTC-R02.1-xxx<br />

FWA-MTCR0*-M01-<strong>19VRS</strong>-NN<br />

MTS-P01.2-xx-xxx<br />

FWA-MTSP01-S01-<strong>19VRS</strong>-NN<br />

FWA-MTSP01-M01-<strong>19VRS</strong>-NN<br />

MTS-P02.2-xx-xxx<br />

FWA-MTSP02-S01-<strong>19VRS</strong>-NN<br />

FWA-MTSP02-M01-<strong>19VRS</strong>-NN<br />

MTS-R01.2-M1-xxx<br />

FWA-MTSR0*-M01-<strong>19VRS</strong>-NN<br />

FWA-MTSR0*-S01-<strong>19VRS</strong>-NN<br />

MTS-R02.2-M1-xxx<br />

FWA-MTSR0*-M01-<strong>19VRS</strong>-NN<br />

FWA-MTSR0*-S01-<strong>19VRS</strong>-NN<br />

Fig. 2-2: Supported hardware types<br />

Version 19 does not support the hardware types of the MT-CNC!<br />

The user interface of the <strong>19VRS</strong> software and firmware version for<br />

<strong>MTC200</strong> can be used under the operating systems MS-DOS (version<br />

6.22) and Windows NT 4.0.<br />

For operating system Windows NT 4.0, service pack 5 is required.<br />

The installation program checks whether the required service pack has<br />

been installed!<br />

Note: The corresponding service pack must be activated again if<br />

additional operating system components (such as a network<br />

driver) are installed subsequently!<br />

Rexroth Indramat supplies version <strong>19VRS</strong> only in conjunction with MS-<br />

DOS 6.22 or Windows-NT 4.0.<br />

Some functions of Version 19 are only available under Windows NT 4.0.<br />

DOK-<strong>MTC200</strong>-NEW*FUN*V19-AW02-EN-P