11.07.2015 Views

EM 2841 EM 2851 - OMS Product Database

EM 2841 EM 2851 - OMS Product Database

EM 2841 EM 2851 - OMS Product Database

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>EM</strong> <strong>2841</strong><strong>EM</strong> <strong>2851</strong>núdzové osvetleniebezúdržbové, 3 hodinovéInštalácia1. oddeľtte difúzor od telesa uvonením každého zo 4 očiekpríchytiek telesa pri použití 5mm skrutkovača2. uvoľnite podnos uvoľnením plastických príchytiek odplastového podnosu a oddeľte ho od podkladu3. upevnite podklad na stenu alebo strop priamo alebo cezskrinku káblovodu uvoľniac vstupný otvor v telese pre kábel4. izolujte zdroj striedavého prúdu a zapojte svietidlo. Vypnutý240V zdroj striedavého prúdu musí byť yapojený doL koncovky uzemnenia a neutrálu N musia byť zapojenédo PCB vo všetkých variantoch. Na podobných variantochsa nepretržité osvetlenie dosahuje pomocou už zapojenéhobieleho článku. Tento môže byť vymenený jednoduchýmvypínačom pre kontrolu zapnutia a vypnutia.5. zastrčte vedenie batérie do prípojkz na PCB.6. znovu upevnite podnos (podstavu) na teleso a skontrolujtesprávne zapadnutie plastikových príchytiek.7. nasaďte difúzor a stlačte každé zo 4 očiek, či je dobreumiestnené8. skontrolujte celú činnosť – zapnite zdroj striedavého prúdu,skontrolujte, či je LED indikátor zapnutý, nechajte hozapnutý po dobu 30min, vypnite prúd, žiarovka by malasvietiť na pár sekúnd.9. zapojte zdroj striedavého prúdu a skontrolujte, či je LEDindikátor zapnutýČinnosťBEZÚDRŽBOVÁŽiarovka sa normálne vypína a batéria automaticky nabíja(LED zapnutá), keď správne funguje zdroj striedavého prúdu.Sústava obvodu automaticky zapína žiarovku pri prerušenízdroja striedavého prúduÚDRŽBOVÁPohotovostná žiarovka normálne funguje, keďje zdroj zapnutý.Batéria sa automaticky dobíja (LED zapnutá). Žiarovka svietii po prerušení striedavého prúdu.KONTROLAČervený indikátor žiarovkz je bežne zapnutý. Prestane svietiťpo prerušení zdroja alebo pri poruche nabíjača.BATÉRIAZaliata nikel-kadmiová nabíjateľná batériaTEPLOTAČinnosť a výkon meraný pri teplote 25°CHľadanie a odstránenie závadKONTROLNÁ LED DIÓDA NESVIETIPorucha v zdroji, vypnutá batéria, alebo vadný nabíjač.SVIETIDLO NEDOSAHUJE POŽADOVANÚPOHOTOVOSTNÚ DĹŽKUPotrebuje správny okruh: je vybitá, znovu ju dobite po dobu24 hodín. Skontrolujte, či netreba vzmeniť batériu.ŽIAROVKA SVIETI LEN ČIASTOČNEAk trubica žiarovky sčerná, treba ju vymeniť. Ak žiarovkabliká alebo má malú intenzitu, treba vymeniť batériu(menej pravdepodobné) alebo obvodový (okruhový) panel.Doporučená pravidelná kontrolaNasledujúca kontrola má zabezpečiť ochranu vášho majetkua zamestnancov. Pretože existuje možnosť zlyhania bežnéhosvetelného zdroja krátko po jeho kontrole, mala by sa kontrolapreviesť za denného svetla.RAZ DENNE – vitzuálna kontrola nabitia batérieS<strong>2841</strong>-51RAZ MESAČNE – každá jednotka by mala byť napájaná zosvojej batérie po dobu 30sek pri simulácii zlyhania bežnéhosvetelného zdroja, aby sa zabezpečila činnosť žiarovkyv núdzových podmienkach.DVA RAZY ROČNE – každá jednotka by mala byť napájanázo svojej batérie po dobu najmenej jednej hodiny.skontrolujte svetelnú trubicu a ak sú jej konce čierne, vymeňteju. Doporučuje sa vymieňať tieto trubice nie viac ako raz zarok, aby sa zachovali dizajnové fotometrické charakteristiky.KAŽDÉ 3 ROKY A KAŽDÝ NASLEDOVNÝ ROK – Všetkysvietidlá s určenou dobou životnosti väčšou ako 1 hodina,by mali byť napájané počas celého obdobia životnosti.


S<strong>2841</strong>-51<strong>EM</strong> <strong>2841</strong><strong>EM</strong> <strong>2851</strong><strong>EM</strong>ERGENCY BULKHEADNON-MAINTAINED3 HOURINSTALLATION- remove the diffuser from the body by easing each of the 4´lugs´ off the body clips using a 5mm flat blade screw driver- release gear tray by easing plastic clips away from the metaltray and lifting the metal tray away from the base- fix base to wall or ceiling either direct or via conduit box havingcleared an access hole in the body for the cable- isolate the A.C. supply and connect unit. An unswitched 230VA.C. supply must be connected to the live, earth and neutral(N) terminals. Fitted to the PCB of all variants. On maintainedvariants continuous illumination is provided by the whitelinkready connected, this can be replaced by a simple switch foron/off control- plug battery lead into connector on PCB- refit the gear tray into the body making sure the one plasticclips capture it corretly- refit diffuser and press each of the 4 ´lugs´ to ensure they arefully located- check operation - restore the A.C. supply, check that the indicatorLED is ´on´ leave for 30 minutes, remove power, the lampshould illuminate for a few seconds- restore the A.C. supply and check that the indicator LED is´on´OPERATIONNON-MAINTAINEDLamp normally off and batery on automatic charge (LED ´on´)when the A.C. supply is healthy. Solid state circuitry automaticallyswitches the lamp on when the A.C. supply is interrupted.MAINTAINEDEmergency lamp normally on, when the supply to switched liveis on. The battery is on automatic charge (LED ´on´). Lampwill switch on or remain on if A.C. supply is interupted.MONITORINGRed indicator lamp (LED) normally continuously ´on´. Indicatorlamp goes out if A.C. supply or charger fails.BATTERYSealed Nickel - Cadmium rechargeable battery pack.T<strong>EM</strong>PERATUREPerformance figures measured at 25 degrees C.FAULT FINDING AND CORRECTIVE ACTIONMONITORING LED NOT ILLUMINATEDA.C.supply not healthy. Battery not connected. Charger failed.UNIT NOT MEETING REQUIRED <strong>EM</strong>ERGENCY PERIODMay need cycling: Discharge then, recharge for full 24 hours.Retest, battery pack may need replacing if emergency durationstill not met.LAMP NOT FULLY ILLUMINATEDIf tube ends blackened, replace tube. If illumination is hesitantand of a low level, either the battery pack or (less likely) theprinted circuit board needs replacing.RECOMMENDED ROUTINE TEST PROCEDUREThe following test is designed to ensure the continued protectionof your premises and occupants. Because of the possibilityof a failure of the normal lighting supply occurring shortly aftera period of testing, all tests should whenever possible, be undertakenat times of least risk, e.g. during daylight hours.ONCE A DAYVisual inspection of battery charge LED.ONCE A MONTHEach unit should be energised from it’s battery for about 30seconds by simulation of a failure of the normal lighting supply,to ensure the lamp operates in the emergency condition.TWICE A YEAREach unit should be energised from it’s battery for a continuousperiod of at least one hour.Inspect the fluorescent tube - if the ends are blackened, replace it.It is recommended that for maintained luminaires the tubes arereplaced at intervals of no more than 1 year in order to retainthe design photometric characteristics.AFTER THREE YEARS AND EACH SUBSEQUENT YEARAll units with specified durations in excess of 1 hour should beenergised for their full rating period.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!