SINAMICS G110Inverter chassis units 0.12 kW to 3 kWControlled Power Modules© Siemens AG 20072■ Technical specificationsPower rangeLine voltageLine frequencyOutput frequencyControlled Power Modules0.12 … 3.0 kW200…240V 1AC±10%47 … 63 Hz0 … 650 Hzcos ϕ ≥ 0.95Inverter efficiency• with devices < 0.75 kW 90 … 94%• with devices ≥ 0.75 kW ≥ 95%Overload capability Overload current 1.5 × rated output current (i.e. 150% overload) for 60 s,then 0.85 × rated output current for 240 s,cycle time 300 sInrush currentControl methodsPulse frequencyFixed frequenciesSkipped frequency rangeSetpoint resolutionDigital inputsAnalog input (analog variant)Digital outputUniversal serial interface (USS variant)Motor cable length, max.• Shielded• UnshieldedElectromagnetic compatibilityBrakingDegree of protectionOperating temperatureLess than rated input currentLinear V/f characteristic (with parameterizable voltage boost);quadraticV/f characteristic;multipoint characteristic (parameterizable V/f characteristic)8 kHz (standard)2 … 16 kHz (in 2 kHz increments)3, programmable1, programmable0.01 Hz digital0.01 Hz serial10 bit analog (motorized potentiometer 0.1 Hz)3 programmable digital inputs, non-floating, PNP, SIMATIC-compatible1, for setpoint (0 V to 10 V, scaleable or for use as 4th digital input)1 isolated optocoupler output (24 V DC, 50 mA, ohmic, NPN type)RS485, for operation with USS protocol25 m50 mAll devices with integrated EMC filter for drive systems incategory C2 installations (limit value in accordance with EN 55011, class A, group 1) andcategory C3 installations (limit value in accordance with EN 55011, class A, group 2).All devices with an integrated EMC filter and shielded cables with a maximum length of 5 m also fulfill thelimit values of EN 55011, class B.DC braking, compound brakingIP20-10…+40°Cup to +50 °C with deratingStorage temperature -40 … +70 °CRelative humidityInstallation altitudeStandard SCCR(Short Circuit Current Rating) 1)Protective functions forCompliance with standardsCE mark95% (non-condensing)Up to 1000 m above sea level without derating• Rated output currentat 4000 m above sea level: 90%• Line voltageup to 2000 m above sea level: 100%at 4000 m above sea level: 75%10 kA• Undervoltage• Overvoltage• Ground fault• Short-circuit• Stall prevention• Thermal motor protection I 2 t• Inverter overtemperature• Motor overtemperatureUL, cUL, CE, c-tickConformity with Low-Voltage Directive 73/23/EEC1) Applies to industrial control cabinet installations to NEC article 409/UL 508A. For further information, visit us on the Internet at:http://support.automation.siemens.com/WW/view/en/239956212/4 Siemens D 11.1· 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!