<strong>SunSaver</strong> <strong>MPPT</strong> MODBUS <strong>Specification</strong>v05EEPROM ValuesEEPROM values that require updating are done so once every 24 hours.Charging Settings (bank 1 & bank 2)Diagram A Charging stages and defining variables.EV_reg [57345][0xE000](V). Regulation voltage (absorption), bank 1 @ 25ºC.EV_reg2 [57558][0xE00D](V). Regulation voltage (absorption), bank 2 @ 25ºC.The battery will charge at 100% charge current until battery voltage reaches this setpoint. The controllerwill begin to taper input current so that this setpoint is maintained, but not exceeded. See diagram A.http://www.morningstarcorp.com 16/26 23 April 2008