D e s c r i p t i o nFHB series filters are designed for pressure lineapplications where manifold mounting is a specificrequirement.The manifold type filters are designed to integrateonto manifold valve systems to provide a compactlow pressure loss and leak free installation.Continued research and development on both thefilter bodies and the filter elements has resulted ina product line with excellent pressure drop characteristicscombined with a high filtration efficiency.A complete line of pressure differential visual andelectrical indicators are available with this seriesof filters.FHB series filters are available with Reverse FlowValve.FHB series filters within this range are suitable forflow rates to 400 l/min. See page 12.FHB series are suitable for industrial machinerysteel and process application.ELECTRICALDIFFERENTIALINDICATORSVISUAL-ELECTRICALNewabsolute filter elementsindependently testedin the following Institutes:VISUALINDICATOR OPTIONSCAST IRON HEADBYPASS VALVEO-RING +RETAINING RINGUNI EN ISO 9001N° 037/98CAPTIVE O-RINGHIGH EFFICIENCYELEMENT WITHHIGH DIRT HOLDINGCAPACITYSTEEL BOWLFHB 05030/6.99/UK Sost. 3.98/UK2


MP Filtri - Filtration technologyFilter element:Filter element materialA SeriesInorganic microfibreExternal support mediaExternal wire meshElement materialAbsolute filtrationNew material:New improved ß ≥ 200filter elements withgreater efficiency andincreased dirt holdingcapacityFiltering areaFilter elementsN - ∆P 20 barEnd caps:Steel (Thermal treatment)Inner supporttubeInternal wire meshMicrofibre filtration mediaInternal support mediaA SeriesInorganic microfibre with acrilic supportFilterelementsß ≥ 2(50%)Support tube:Steel (Thermal treatment)Dimensions forß(µm) valuesß ≥ 20(95%)ß ≥ 75(98,7%)ß ≥ 200(99,5%)Support frames:Coated wire clothContamination retentionas per ISO 4572: Multi-pass test.Filtration ratiosß2 ß10 ß20A03 _ 2 2,4 3 20 >10.000 >10.000 7A06_ 3 4,6 6 8 > 2.000 >10.000 7A10 3 6 7,8 10 1,5 ≥ 200 >10.000 7A25 13 19 22 25_> 1,5 > 35 7N.B. Other materials giving different degrees of filtration are available on request.Type HPA03/A06A10/A25Type HPMP Filter elements - Conform to the followingISO standardsISO 2941 - Verification of collapse/burst resistance.ISO 2942 - Verification of fabrication integrity and determinationof the first bubble point.ISO 2943 - Verification of material compatibility with fluids.ISO 3723 - Method for end load test.ISO 3724 - Verification of flow fatigue characteristics.ISO 3968 - Evaluation of pressure drop versus flow characteristics.ISO 4572 - Multi-pass method for evaluating filtration performance.386 546 1098 895 1879 1512 3326 5428386 546 1098 895 1879 1512 3326 5428∆ P(bar)065-1 065-2 065-3 135-1 135-2 320-1 320-2 320-3 320-475447544Values in cm 2065-1 065-2 065-3 135-1 135-2 320-1 320-2 320-3 320-4Filtering areaA03/A06Filter elementsA10/A25H - ∆P 210 bar 2386 544 1094 777 1655 1475 3258 5341386 544 1094 777 1655 1475 3258 5341Values in cm74257425Element materialNominal filtrationM SeriesT SeriesFiltering areaFilter elementsN - ∆P 20 barFiltering areaFilter elementsT - ∆P 80 barSquare wire mesh (filtration degree is defined in microns by themaximum diameter of a sphere corresponding to the mesh size)M10M25M60Triangular stainless steel wire meshType HP 065-1 065-2 065-3 135-1 135-2 320-1 320-2 320-3 320-4374 530 1064 950 2020 1650 3645 5970 8280374 530 1064 950 2020 1650 3645 5970 8280374 530 1064 950 2020 1650 3645 5970 8280Values in cm 2Type HP 065-1 065-2 065-3 135-1 135-2 320-1 320-2 320-3 320-4T10/T25 385 545 1090 710 1500 1670 3690 6040 8380Values in cm 23


MP Filtri - SpecificationFilter body:MaterialsHeadCast iron (Thermal treatment)BowlSteel (Thermal treatment)Bypass valveBrassReverse flow (Only for 135/320 series)SteelWorkingtemperaturePressure filterbodySealsA Series: Nitrile (Buna-N)V Series: VitonMaximum working pressure up to 320 barTest pressure: 420 barMinimum burst pressure: 840 barIndicatorBrass (with viton seals)From -25 to +110°CFor temperatures outside this range, pleaseconsult our Sales Network OrganizationFatigue test: a filter body subjected topressure impulses from 0 to 320 bar willwithstand 1.000.000 cyclesCollapse pressurefilter elements N Series: 20 barBypass valveCalibration pressureCompatibilitywith fluidsBypass valve, differential opening pressure:Filter head and bowlscompatible for use with:• mineral oils(types HH-HL-HM-HR-HV-HG as per ISO 6743/4)• water-based emulsions(types HFAE-HFAS as per ISO 6743/4)• synthetic fluids(types HS-HFDR-HFDS-HFDU as per ISO 6743/4)• water-glycol (types HFC as per ISO 6743/4)H Series:H Series:B: 6 bar ± 10%80 bar210 barFilter elementsAs per ISO 2943; suitable for mineral oils(types HH-HL-HM-HR-HV-HG as per ISO 6743/4)and synthetic fluids (A and M series only)(types HS-HFDR-HFDS-HFDU as per ISO 6743/4)For water-based emulsions (types HFAE-HFASas per ISO 6743/4) and fluids other thanthose mentioned, please consult our SalesNetwork Organization.Types of indicatorsVisual indicatorElectrical indicatorVisual-electricalindicatorSealsA SeriesNitrile (Buna-N) compatible with mineral oils(types HH-HL-HM-HR-HV-HG as per ISO 6743/4)(Complete with Viton seals)Description: FHB series filters are fitted withindicators switching at a pressure of5 bar ± 10%(for N elements series)7 bar ± 10%(for H and T elements series)10 bar ± 10%(for H and T elements series)With bypass 5 bar setting:V7 SeriesWith bypass 5 bar setting:N7 SeriesWith bypass 5 bar setting:E7-K7* SeriesWithout bypass 7 bar setting:V8 SeriesWithout bypass 7 bar setting:N8 SeriesWithout bypass 7 bar setting:E8-K8* Series*For K visual-electrical indicator, specify the voltage (f.i. K71 = LED 24 volt)water-based emulsions(types HFAE-HFAS as per ISO 6743/a)water - glycol (types HFC as per ISO 6743/4)V SeriesViton compatible with synthetic fluids(types HS-HFDR-HFDS-HFDU as per ISO 6743/4)“J series - Thermal lockout ElectricalIndicators available - contact MP Filtri”Without bypass 10 bar setting:V9 SeriesWithout bypass 10 bar setting:N9 SeriesWithout bypass 10 bar setting:E9-K9* Series{* 1 - 24 Volt2 - 115 Volt3 - 230 Volt4


MP Filtri - SpecificationK - E - N SeriesSupply voltage (50/60 Hz)(V)Vca 125Vca 250Vcc 30Vcc 125Vcc 250Resistive load(A)5550,50,25Inductive load(A)2230,030,03CONNECTOR DIN 43650ELECTRICAL CONNECTIONE - N SERIESN.C.N.O.ELECTRICAL CONNECTIONK SERIESN.C.N.O.Visual V seriesElectrical N seriesVisual - Electrical K seriesVisual - Electrical E series383838,5LedA/F 30A/F 3265A/F 3065762827272869A/F 32Ø16G1/2”Ø16G1/2”Ø16G1/2”Ø16G1/2”5


Selection& installation informationFilter ElementstypesA SeriesAbsolute inorganic microfibrefiltration media, available in3, 6, 10 and 25 micronExample - A03, A06, A10 or A25M SeriesMetal mesh media,available in 10, 25and 60 micronExample - M10, M25 or M60T SeriesTriangular stainless steelmesh media, availablein 10, 25 micronExample - T10, T25Please refer to individual pressure drop curves to obtain filter assembly pressure drop informationThe following filter sizing recommendations are based using a mineral oil fluid at 30 mm 2 /s (cSt), with a maximum filter assembly(housing and filter element) pressure drop of 25% of the filter condition indicator (1.25 bar)FHB 065 SERIESØ15 Ø15421295A/F 30IndicatorportA/F 3242FHB 065VFilterassemblyA03A06A10A25Flow ratel/minN series*18203550Flow ratel/minH-T series*15183248BowllengthPort sizeBSP/NPT/SAEWeightkg**1 – 3,0T10–75A/F 30A/F 30A032218HA0635256538NA10A25T105075–4565902–3,6A/F 30LedA03A0635603050100Ø 68A/F 306538KA10A25T107590–65801103 – 4,0A/F 32** Flow rates with 30 mm 2 /s fluid viscosity** Weight including filter elementELengths38,5TypeH761 1882 2103315FRONT VIEW1,00Housing pressure drop curveFHB 06583580,75N°2 holes Ø 112 631 = =67∆p bar0,500,250,000 20 40 60 80 100Flow rate l/min6


Selection& installation informationPlease refer to individual pressure drop curves to obtain filter assembly pressure drop informationThe following filter sizing recommendations are based using a mineral oil fluid at 30 mm 2 /s (cSt), with a maximum filter assembly (housing andfilter element) pressure drop of 25% of the filter condition indicator (1.25 bar)FHB 135 SERIESØ20 Ø205020110A/F 30IndicatorportA/F 3242FHB 135VFilterassemblyA03A06A10A25T10A03A06A10Flow ratel/minN series*506080100–100110140Flow ratel/minH-T series*355060751508090120BowllengthPort sizeBSP/NPT/SAEWeightkg**1 – 6,72–8,1A/F 30A/F 30A25180150HT10–1806538N** Flow rates with 30 mm 2 /s fluid viscosity** Weight including filter elementA/F 30LedLengthsTypeH125Ø 80A/F 306538K1 2712 385A/F 32E38,576FRONT VIEW1,00Housing pressure drop curveFHB 135110720,753519.555104∆p bar0,50N°4 holes Ø 180,250,00*0 40 80 120 160 200Flow rate l/min7


Selection& installation informationPlease refer to individual pressure drop curves to obtain filter assembly pressure drop informationThe following filter sizing recommendations are based using a mineral oil fluid at 30 mm 2 /s (cSt), with a maximum filter assembly (housing andfilter element) pressure drop of 25% of the filter condition indicator (1.25 bar)FHB 320 SERIES150 HØ32 Ø321606530Ø 105A/F 30A/F 30IndicatorportA/F 46A/F 32426565A/F 32A/F 30FHB 32038A/F 30Led3838,5VNKEFilterassemblyA03A06A10A25T10A03A06A10A25T10A03A06A10A25T10A03A06A10A25T10Flow ratel/minN series*100120140180–210250300350–250280320350–300340375400–Flow ratel/minH-T series*6580100150200150180220250275225250280340360250275320380400BowllengthPort sizeBSP/NPT/SAEWeightkg**1 – 13,0234–––15,021,024,076** Flow rates with 30 mm 2 /s fluid viscosity** Weight including filter elementLengthsFRONT VIEW14095Only for FHB 320-4Type H1 3152 4253 562N°4 holes Ø 235258 25110A/F 3012041,00692Housing pressure drop curveFHB 3200,75∆p bar0,500,2580,000 75 150 225 300 375Flow rate l/min


Pressure drop informationGeneralPressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 3968Filter assembly pressure drop - ∆p Total = ∆p Housing + ∆p Filter elementHousing pressure drop - The housing pressure drop is proportional to the fluid densityFilter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check thefluid operating temperature and fluid type to obtain the working viscosity according to the following formula:∆p 1 Filter element = (working viscosity/brochure viscosity) x ∆p filter elementBrochure viscosity 30 mm 2 /s (cSt)Selection :• Customer requires a 90 l/min filter assembly• Mineral oil fluid: ISO VG 46 (46 mm 2 /s (cSt) at 40°C)• A10 - 10 micron absolute filtration•Housing pressure drop - FHB 135-2 with 90 l/min ∆p = 0.2 bar (see curve on page 7)Filter assembly sizing example•Filter element pressure drop (brochure viscosity) - HP 135-2A10AN with 90 l/min ∆p = 0.55 bar (see curve on page 10)•Filter element pressure drop (working viscosity) - With 46 mm 2 /s (cSt) ∆p 1 = 0.55 x ( 46/30 ) = 0.85 bar•Filter assembly pressure drop ∆p Total = ∆p Housing + ∆p 1 Filter element = 0.2 + 0.85 = 1.05 bar*{*Acceptable pressure drop value asper our recommendationsBypass valves pressure dropThe curves were obtained using a mineral oil with a density of 0,86 kg/dm 3 .The ∆p varies proportionally to the density.12FHB 06516FHB 13516FHB 32091212∆p bar63∆p bar84∆p bar8400 7 14 21 28 35 42Flow rate l/min00 15 30 45 60 75 90Flow rate l/min00 40 80 120 160 200 240Flow rate l/minReverse flow valves pressure dropThe curves were obtained using amineral oil with a density of 0,86 kg/dm 3 .The ∆p varies proportionally to the density.1,000,75FHB 1351,000,75FHB 320∆p bar0,50∆p bar0,500,250,250,000 20 40 60 80 100Flow rate l/min0,000 40 80 120 160 200Flow rate l/min9


Filter elements - N - ∆ P 20barThe curves were obtained using a mineral oil with a kinematic viscosity of 30 mm 2 /s (cSt).The ∆p varies proportionally to the fluid kinematic viscosity.For the metal filter elements curves (M series),please consult our Sales and Network Organization∆p bar2,001,501,00A03HP 065-1 A...NA06A10A25∆p bar2,001,501,00A03HP 065-2 A...NA06 A10A250,500,500,000 10 20 30 40 50 60Flow rate l/min0,000 15 30 45 60 75 90Flow rate l/min∆p bar2,001,501,00HP 065-3 A...NA03A06A10∆p bar2,001,501,00A03HP 135-1 A...NA06A10A250,50A250,500,000 15 30 45 60 75 90Flow rate l/min0,000 25 50 75 100 125 150Flow rate l/min2,00HP 135-2 A...NA032,00HP 320-1 A...NA03 A06∆p bar1,501,000,50*A06A10A25∆p bar1,501,000,50A10A250,000 30 60 90 120 150 180Flow rate l/min0,000 40 80 120 160 200 240Flow rate l/min2,00HP 320-2 A...N2,00HP 320-3 A...N∆p bar1,501,000,500,00A03A06A10A250 50 100 150 200 250 300Flow rate l/min∆p bar1,501,000,500,00A03A06A10A250 75 150 225 300 375 450Flow rate l/min2,00HP 320-4 A...N∆p bar1,501,000,50A03A06A10A250,000 75 150 225 300 375 450Flow rate l/min10


Filter elements - H - ∆P 210barThe curves were obtained using a mineral oil with a kinematic viscosity of 30 mm 2 /s (cSt).The ∆p varies proportionally to the fluid kinematic viscosity.2,001,50A03A06HP 065-1 A...HA10A252,001,50A03HP 065-2 A...HA06 A10A25∆p bar1,000,50∆p bar1,000,500,000 10 20 30 40 50 60Flow rate l/min0,000 15 30 45 60 75 90Flow rate l/min∆p bar2,001,501,00A03HP 065-3 A...HA06A10A25∆p bar2,001,501,00HP 135-1 A...HA03 A06 A10 A250,500,500,000 15 30 45 60 75 90Flow rate l/min0,000 25 50 75 100 125 150Flow rate l/min∆p bar2,001,501,00HP 135-2 A...HA03A06A10A25∆p bar2,001,501,00HP 320-1 A...HA03 A06 A10 A250,500,500,000 30 60 90 120 150 180Flow rate l/min0,000 40 80 120 160 200 240Flow rate l/min∆p bar2,001,501,00HP 320-2 A...HA03A06A10A25∆p bar2,001,501,00HP 320-3 A...HA03A06A10A250,500,500,000 50 100 150 200 250 300Flow rate l/min0,000 75 150 225 300 375 450Flow rate l/min2,00HP 320-4 A...H∆p bar1,501,000,50A03A06A10A250,000 75 150 225 300 375 450Flow rate l/min11


International standards for contamination fluid controlCONTAMINATIONCODESISO 4406CORRESPONDENTCODESNAS 1638RECOMMENDEDFILTRATION DEGREETYPICAL APPLICATIONS5 µm15 µmßx ≥20012933High precision and laboratory servo-systems151163-6Robotic and servo-systems1613710-12Very sensitive systems where a high degree of1814912-15reliability is required19161015-25General equipment of limited reliability21181225-40Low - pressure equipment not in continuos serviceReverse flow valve - DrawingFHB 135 - FHB 320 SERIESOUTIN1) 2)3) 4)ZERO FLOW FLOW BYPASS REVERSE FLOW12


Ordering informationFHBF1065135320Nominal sizesBowl lengthsFHB 065 = 1, 2, 3FHB 135 = 1, 2FHB 320 = 1, 2, 3, 4Filter condition indicatorS With threaded hole onlyT2 With plugV7 Visual 5 barV8 Visual 7 barV9 Visual 10 barN7 Electrical 5 barN8 Electrical 7 barN9 Electrical 10 barE7 Visual - electrical 5 barE8 Visual - electrical 7 barE9 Visual - electrical 10 barK7* Visual - electrical 5 barK8* Visual - electrical 7 barK9* Visual - electrical 10 bar1 - 24 Volt2 - 115 Volt*{3 - 230 Volt*For K visual-electrical indicator, specify the voltage (f.i. K71 = LED 24 volt)SBWRIntegral bypass valveWithout bypassWith bypassWith reverse flowWith reverse flow + bypass( Not available )for FHB 065Collapse pressure seriesN 20 barT 80 barH210 barAVNitrile (Buna-N)VitonSealsA03A06A10A25M10M25M60T10T25Filter elementsInorganic microfibre Bx ≥200Square wire meshStainless steel wire meshHPReplacement elementMP Filtri - Filtration products will only be guaranteed if original MP Filtrireplacement elements and spares are usedData hold in this pubblication are given only for indicative purposes. MP Filtri reserves to introducemodifications to describe items in every moment either for technical or commercial reasons. Copyright reserved.13


Notes14


Notes15


Head Quarter :MP FILTRI S.p.A. ItalyVia Matteotti, 220060 Pessano con Bornago (Milano) ItalyTel. ++39.02/95703.1Fax ++39.02/95741497-95740188email: sales@mpfiltri.comhttp://www.mpfiltri.comGREAT BRITAINMP FILTRI U.K. Ltd.Bourton Industrial ParkBourton on the WaterGloucestershire GL54 2HQ UKPhone: 01451-822522Fax: 01451-822282email: sales@mpfiltri.co.ukhttp://www.mpfiltri.co.ukGERMANYMP FILTRI D GmbHAm Wasserturm 5D-66265 Heusweiler/HolzPhone: 06806/85022-0Fax: 06806/85022-18email: mpfiltrink@aol.comFRANCEMP FILTRI FRANCEB.P. 32501603 Trevoux CedexTel: 04.74.08.84.78Telefax: 04.74.08.80.45email: mpfiltrifrance@wanadoo.frUSAMP FILTRI USA Inc.2055 Quaker Pointe DriveQuakertown, PA 18951Phone: 215-529-1300Fax: 215-529-1902email: mpusasales@aol.comhttp://www.mpfiltriusa.comCANADAMP FILTRI CANADA Inc.210 Jacob Keffer Parkway Concord,Ontario Canada L4K 4W3Phone: 905-303-1369Fax: 905-303-7256email: mail@mpfiltricanada.comhttp://www.mpfiltricanada.com