Ethernet

elektrosistem.ba
  • No tags were found...

Ethernet

Synergies of the Industrial Automation Business UnitIndustrie-PCsIndustrial mit offener Automation Systemarchitektur Business UnitICDIABComponentsandsolutionsall from onesupplierDarwinTechnologyThe September 1 st , 2009 founded Industrial Automation Business Unit, short IAB, offers solutions fromthe control cabinet down to the periphery.Through the joining of three complimentary product sections (ICD+IAB) into one business unit aperfect approach to application solutions can be universally offered from switchboard building up toglobal OEMs.A world wide market presents with coordinated sales channels and a performatable solution andapplication support is a further trademark of the IAB.4www.microinnovation.com


The Four Performance ClassesFor every task the rightOEM solutionOver 150protocolsPPIUnitelwayRS232Industrial EthernetDF1SUCOnet K ADSUSB MPIThe four performance classes at a glance:CompactThe compact class directs itsself towards the machine and aggregate builders in the low cost price segmentwithout lowering the level of performance.StandardThe standard class covers the performance demands of middle standard machines.UniversalThe universal class is concepted for middle and bigger OEM machines because of its modular hardwarestructure and flexible employment.PerformanceThe performance class offers open hard- and software platforms for high-end automation.5


XP700Industrial PCXP70015“, 19“ color, Box 15“ 19“ BoxFunctionOpen HMIFront Standard -Touch infra-red -Display TFT-LCD color 15“ TFT-LCD color 19“ -Resolution XGA 1024 x 768 SXGA 1280 x 1024 -Number of usable colors adjustable: 16.7m, 65k or 256 colors -Backlight 4 CCFL -Protective panel Safety glass, non-reflective -Processor Pentium 1GHzMemory 1024MBProcessor Pentium 1.8GHzMemory 2048MBOptional memory cardsXP-702-C0-15TXI-1085 36 000130XP-702-D0-15TXI-1085 36 0002302 x CompactFlashOptional hard disk 1 x 2.5“Operating systemXP or XPeXP-702-C0-BOX-1085 36 000170XP-702-D0-BOX-1085 36 000270Video interface CRT analog DVI, CRT analogInterfaces onboardSlots for modulesRated valueProtection typein the pipeline4 x USB, Ethernet 10/100, Ethernet 10/100/1000, 2 x RS2321 x PCI or PCI-Express24VDCIP65 front,IP20 rearDimensions of device (WxH) 427 x 332mm 512 x 420mm 262 x 194mmDepth with / without active cooling 119mm / 83mm 122mm / 86mm 96mm / 60mmMounting cutout (WxH) 410 x 315mm 495 x 403mm -Weight approx. 6.4kg approx. 8.3kg approx. 1.9kgXP700 with touch display or as a boxversion for headless operation up to5m distance (typically).9


AccessoriesDescription Type / Article no. For use withWindows XP licensesLicense product paper Windows XPLicense product paper Windows XP EmbeddedMemoryCompactFlash memory card, min. 2GBCompactFlash memory card, min. 2GBWindows XP embedded installed, license requiredStandard hard disk, min. 80GBStandard hard disk, min. 80GBWindows XP embedded installed, license requiredStandard hard disk Industrial Grade, min. 80GBStandard hard disk Industrial Grade, min. 80GBWindows XP embedded installed, license requiredExternal fanExternal standard fanLIC-OS-XP-S91 30 600101LIC-OS-EXP-S91 30 600106MEMORY-CF-A7-S50 61 000401OS-FLASH-A7-S90 17 000140HDU-A7-S90 17 000211OS-HDU-A7-S90 17 000210HDU-A7-SI90 17 000212OS-HDU-A7-SI90 17 000220ACCESSORIES-FAN-700-S45 60 000003XP-7...XP-7...XP-7...XP-7...XP-7...XP-7...XP-7...XP-7...XP-7...10www.microinnovation.com


XV100HMI/PLC with touch displayCompact operator interface with lots of power• Full graphical 3.5“, 5.7“ or 7“-Widescreen TFT display with resistive touch screen• High performance 400MHz RISC-Processor for PLC applications• Onboard memory of 128MB on demand expandable with a SD card• Nominal installation depth• Ethernet interface onboard, furthermore CAN, Profibus, RS232 or RS485 possible• USB Host interface from 5.7“ to 7“-Widescreen display sizeXV1003.5“ mono Version A Version B (PLC)Function HMI (no PLC function possible) HMI/PLCFrontTouchStandardresistiveDisplay TFT mono display 3.5“ResolutionNumber of usable colorsBacklightProtective panelProcessorMemoryInternal Flash memoryQVGA 320x24032 grayscalesLED, dimmableGlass, non-reflective32Bit RISC, 400MHz64MB DRAM128MB NAND FlashRetain memory without 32kB NVRAMOptional memory cardsOperating system1x SD memory card slotWinCE 5.0 Core (included)Visualization / PLC programming GALILEO GALILEO / MXproInterfaces onboard:- Ethernet XV-102-A0-35MQR-10Art.Nr. 85 34 000200- Ethernet, RS232 XV-102-A3-35MQR-10Art.Nr. 85 34 000220- Ethernet, RS485 XV-102-A4-35MQR-10Art.Nr. 85 34 000230- Ethernet, Profibus XV-102-A2-35MQR-10Art.Nr. 85 34 000240- Ethernet, RS232, CAN XV-102-A5-35MQR-10Art.Nr. 85 34 000050XV-102-B0-35MQR-10-PLCArt.Nr. 85 34 000400XV-102-B3-35MQR-10-PLCArt.Nr. 85 34 000430XV-102-B4-35MQR-10-PLCArt.Nr. 85 34 000440-XV-102-B5-35MQR-10-PLCArt.Nr. 85 34 000450- Ethernet, RS485, CAN - XV-102-B6-35MQR-10-PLCArt.Nr. 85 34 000460- Ethernet, RS485, Profibus - XV-102-B8-35MQR-10-PLCArt.Nr. 85 34 000480Rated value24VDC SEL VProtection typeIP65 front, IP20 rearDimensions Device (WxHxD)136 x 100 x 30mmMounting cutout (WxH)123 x 87mmWeightapprox. 0.25kg12www.microinnovation.com


XV100HMI/PLC with touch display1 SD card2 USB Device3 Ethernet4 onboard interfaces, depending on the versionXV1003.5“ color Version B Version B (PLC)Function HMI (no PLC function possible) HMI/PLCFrontTouchStandardresistiveDisplay TFT color display 3.5“ResolutionNumber of usable colorsBacklightProtective panelProcessorMemoryInternal Flash memoryRetain memoryOptional memory cardsOperating systemQVGA 320x24064k colorsLED, dimmableGlass, non-reflective32Bit RISC, 400MHz64MB DRAM128 MB NAND Flash32kB NVRAM1x SD memory card slotWinCE 5.0 Core (included)Visualization / PLC programming GALILEO GALILEO / MXproInterfaces onboard:- Ethernet XV-102-B0-35TQR-10Art.Nr. 85 34 000100- Ethernet, RS232 XV-102-B3-35TQR-10Art.Nr. 85 34 000130- Ethernet, RS485 XV-102-B4-35TQR-10Art.Nr. 85 34 000140- Ethernet, Profibus XV-102-B2-35TQR-10Art.Nr. 85 34 000120- Ethernet, RS232, CAN XV-102-B5-35TQR-10Art.Nr. 85 34 000150XV-102-B0-35TQR-10-PLCArt.Nr. 85 34 000500XV-102-B3-35TQR-10-PLCArt.Nr. 85 34 000530XV-102-B4-35TQR-10-PLCArt.Nr. 85 34 000540-XV-102-B5-35TQR-10-PLCArt.Nr. 85 34 000550- Ethernet, RS485, CAN - XV-102-B6-35TQR-10-PLCArt.Nr. 85 34 000560- Ethernet, RS485, Profibus - XV-102-B8-35TQR-10-PLCArt.Nr. 85 34 000580Rated value24VDC SEL VProtection typeIP65 front, IP20 rearDimensions Device (WxHxD)136 x 100 x 30mmMounting cutout (WxH)123 x 87mmWeightapprox. 0.25kg13


XV100HMI/PLC with touch displayThe 3 display sizes of XV100 by comparison:3.5“5.7“ 7“ WideXV1005.7“ color Version B Version B (PLC)Function HMI (no PLC function possible) HMI/PLCFrontTouchStandardresistiveDisplay TFT color display 5.7“ResolutionNumber of usable colorsBacklightProtective panelProcessorMemoryInternal Flash memoryRetain memoryOptional memory cardsOperating systemVGA 640x48064k colorsLED, dimmableGlass, non-reflective32Bit RISC, 400MHz64MB DRAM128 MB NAND Flash32kB NVRAM1x SD memory card slotWinCE 5.0 Core (included)Visualization / PLC programming GALILEO GALILEO / MXproInterfaces onboard:- Ethernet, USB- Ethernet, USB, RS232- Ethernet, USB, RS485- Ethernet, USB, Profibus- Ethernet, USB, RS232, CAN- Ethernet, USB, RS485, CAN- Ethernet, USB, RS485, ProfibusRated valueProtection typeavailable from 2nd quarter 2010 onwards24VDC SEL VIP65 front, IP20 rear1 SD Karte2 USB Device3 USB Host4 Ethernet5 onboard interfaces, depending on the version14www.microinnovation.com


XV100HMI/PLC with touch displayXV1007“ widescreen color Version B Version B (PLC)Function HMI (no PLC function possible) HMI/PLCFrontTouchDisplayResolutionNumber of usable colorsBacklightProtective panelProcessorMemoryInternal Flash memoryRetain memoryOptional memory cardsOperating systemStandardresistiveTFT color display 7“ WideWVGA 800x48064k colorsLED, dimmableGlass, non-reflective32Bit RISC, 400MHz64MB DRAM128 MB NAND Flash32kB NVRAM1x SD memory card slotWinCE 5.0 Core (included)Visualization / PLC programming GALILEO GALILEO / MXproInterfaces onboard:- Ethernet, USB- Ethernet, USB, RS232- Ethernet, USB, RS485- Ethernet, USB, Profibus- Ethernet, USB, RS232, CAN- Ethernet, USB, RS485, CAN- Ethernet, USB, RS485, ProfibusRated valueProtection typeavailable from 3rd quarter 2010 onwards24VDC SEL VIP65 front, IP20 rear1 SD Karte2 USB Device3 USB Host4 Ethernet5 onboard interfaces, depending on the version15


XV200HMI/PLC with touch displayFlexible communicationThe new XV200 touch display device series offers either a fully graphical 5.7“ FSTN monochrome display with 256 grayscales or a fullygraphical 5.7“ color display with 256 colors, industrial resistive touch technology as well as a wide range of communication and networkoptions. The touch-sensitive display ensures intuitive operation and visualization. Language-neutral and self-explanatory touchswitches can be created to provide clearly designed operating screens. PLC functionality can be implemented on the XV200 devices ifrequired. All devices come with an Ethernet and USB Device interface. Depending on the device type, CAN, Profibus (MPI/PPI/DP) orRS232 can be provided as additional interfaces.XV2005.7“ mono XV-230-57CNN-1-10 XV-230-57MPN-1-10 XV-232-57BAS-1-10FunctionFrontTouchHMI with optional PLCStandardresistiveDisplay FSTN-LCD (mono display) 5.7“Resolution QVGA 320 x 240Number of usable colorsBacklightProtective panelProcessorMemoryRetain memoryInternal Flash memoryOptional memory cardsOperating system256 grayscales1 CCFL, dimmableGlass, non-reflectiveRISC 32Bit, 200MHz32MB100Byte1.5MB linear1 x CompactFlashInterfaces onboard Ethernet, CAN Ethernet, Profibus Ethernet, RS232Slots for communication modules -Rated valueProtection typeDimensions of device (WxHxD)Mounting cutout (WxH)WeightWinCE24VDCIP65 front, IP20 rear212 x 156 x 55mm198 x 142mmapprox. 0.7 kgArticle no. 85 28 200010 85 28 200050 85 28 2000001 RS2322 CAN or Profibus3 Ethernet4 CompactFlash16www.microinnovation.com


XV200HMI/PLC with touch displayXV2005.7“ color XV-252-57CNN-1-10 XV-252-57MPN-1-10FunctionFrontTouchHMI with optional PLCStandardresistiveDisplay CSTN-LCD (color display) 5.7“Resolution QVGA 320 x 240Number of usable colorsBacklightProtective panelProcessorMemoryRetain memoryInternal Flash memoryOptional memory cardsOperating system256 colors1 CCFL, dimmableGlass, non-reflectiveRISC 32Bit, 200MHz32MB100Byte1.5 MB linear1 x CompactFlashInterfaces onboard Ethernet, RS232, CAN Ethernet, RS232, ProfibusSlots for communication modules -Rated valueProtection typeDimensions of device (WxHxD)Mounting cutout (WxH)WeightWinCE24VDCIP65 front, IP20 rear212 x 156 x 55mm198 x 142mmapprox. 0.7 kgArticle no. 85 28 200510 85 28 200550Portrait formatThe panels can be used in portrait format(rotated 90°) if required.17


XVS400HMI/PLC with touch displayCompact system for worldwide useThanks to the extensive range of interfaces available onboard, the XVS400 compact devices can be adapted to the world‘s leadingautomation systems. The Profibus Master interface provided and the robust infra-red touch make the XVS devices highly flexible alternativesfor the visualization and automation world. With versatile Ethernet and USB interfaces as well, these products offer the mostadvanced networking options. Devices with color screens and a screen diagonal of 5.7“ to 12.1“ are available. The integral IEC 61131-3compliant PLC supports all the programming languages of the standard including structured text and sequential function chart for theoptimum implementation of the control task.XVS4005.7“, 8.4“, 10.4“ color 5.7“ 8.4“ 10.4“FunctionFrontInfra-red touch,safety glass, non-reflectiveResistive touch,glass, non-reflectiveXVS-460-57MPI-1-1085 31 200130XVS-450-57MPI-1-1085 31 200120HMI with optional PLCStandardXV-460-84MPI-1-1085 31 200150XVS-440-10MPI-1-1085 31 200300- XVS-430-10MPI-1-1085 31 200200Display 5.7“ TFT-LCD color 8.4“ TFT-LCD color TFT-LCD color 10.4“Resolution QVGA 320 x 240 VGA 640 x 480Number of usable colors 65‘536Backlight LED, dimmable 2 CCFL, dimmableProcessorMemoryRetain memoryInternal Flash memoryRISC 32Bit, 400MHz64MB32kB1.5MB linearoptional memory cards 1 x CompactFlash 2 x CompactFlashOperating systemInterfaces onboardRated valueProtection typeWinCEEthernet, RS232, USB-Host, USB-Device, Profibus24VDCIP65 front,IP20 rearDimensions device (WxHxD) 212 x 156 x 55 mm 275 x 208 x 75 mm 345 x 260 x 67mmMounting cutout (WxH) 198 x 142mm 261 x 194 mm 329 x 238mmWeight approx. 1.8 kg approx. 2.6 kg approx. 3.7kg18www.microinnovation.com


XVS400HMI/PLC with touch displayXVS40012.1“, 15“ color 12.1“ 15“FunctionFrontInfra-red touch,safety glass, non-reflectiveResistive touch,glass, non-reflectiveXVS-440-12MPI-1-1085 31 200500XVS-430-12MPI-1-1085 31 200400HMI with optional PLCStandardXVS-460-15MPI-1-1085 31 200700Display TFT-LCD color 12.1“ TFT-LCD color 15“Resolution SVGA 800 x 600 XVGA 1024 x 768Number of usable colors 65‘536BacklightProcessorMemoryRetain memoryInternal Flash memoryoptional memory cardsOperating systemInterfaces onboardRated valueProtection type2 CCFL, dimmableRISC 32Bit, 400MHz64MB32kB1.5MB linear2 x CompactFlashWinCEEthernet, RS232, USB-Host, USB-Device, Profibus24VDCIP65 front,IP20 rearDimensions device (WxHxD) 361 x 279 x 67mm 427 x 332 x 73mmMounting cutout (WxH) 344 x 262mm 410 x 315mmWeight approx. 4.5kg approx. 5.8kg-2x Compact Flash1 RS2322 Ethernet3 USB Device4 2x USB Host5 Profibus19


XV400HMI/PLC with touch displayThe communication professionalThe devices of the XV400 series offer a wide range of communication options. One or two optional communication modules, enablingeight communications at the same time, as well as CAN, Ethernet 10/100Mbit, USB Host, USB Device, RS232 directly onboard ensuremaximum flexibility, whether as HMI, HMI-PLC, panel with gateway function or as a connection via Ethernet TCP/IP to the control level.Onboard functions such as WEB browser, FTP server, remote client/ server or OPC client offer not only new networking options andprogramming options, they also provide customers and users with a considerable innovation edge for their automation solution.XV4005.7“, 8.4“ color 5.7“ 5.7“ stainless steel 8.4“FunctionHMI with optional PLCFront Standard Stainless steel StandardInfra-red touch,safety glass, non-reflectiveResistive touch,glass, non-reflectiveXV-460-57TQB-1-1085 17 200290XV-450-57TQB-1-1085 17 200292XV-460-57TQB-1-5085 17 200291XV-460-84TVB-1-1085 17 200295- -Display TFT-LCD color 5.7“ TFT-LCD color 8.4“Resolution QVGA 320 x 240 VGA 640 x 480Number of usable colors 65‘536Backlight LED, dimmable 2 CCFL, dimmableProcessorMemoryRetain memoryInternal Flash memoryOptional memory cardsOperating systemInterfaces onboardRISC 32Bit, 400MHz64MB32kB1.5MB linear1 x CompactFlashWinCEEthernet, RS232, USB-Host, USB-Device, CANSlots for communication modules 1Rated valueProtection type24VDCIP65 front,IP20 rearDimensions device (WxHxD) 212 x 156 x 76mm 275 x 208 x 95mmMounting cutout (WxH) 198 x 142mm 261 x 194mmWeight approx. 1.9kg approx. 2.3kg approx. 3.0kg1 RS2322 CAN3 USB Host4 Ethernet5 Communication module6 CompactFlash20www.microinnovation.com


XV400HMI/PLC with touch displayXV40010.4“, 12.1“ color 10.4“ 10.4“ stainless steel 12.1“ 12.1“ stainless steelFunctionHMI with optional PLCFront Standard Stainless steel Standard Stainless steelInfra-red touch,safety glass, non-reflectiveResistive touch,glass, non-reflectiveXV-440-10TVB-1-1085 17 200400XV-430-10TVB-1-1085 17 200300XV-440-10TVB-1-5085 17 200575XV-440-12TSB-1-1085 17 200700- XV-430-12TSB-1-1085 17 200600Display TFT-LCD color 10.4“ TFT-LCD color 12.1“Resolution VGA 640 x 480 SVGA 800 x 600Number of usable colors 65‘536BacklightProcessorMemoryRetain memoryInternal Flash memoryOptional memory cardsOperating systemInterfaces onboard2 CCFL, dimmableRISC 32Bit, 400MHz64MB32kB1.5MB linear2 x CompactFlashWinCEEthernet, RS232, USB-Host, USB-Device, CANSlots for communication modules 2Rated valueProtection type24VDCIP65 front,IP20 rearDimensions device (WxHxD) 345 x 260 x 93mm 361 x 279 x 93mmMounting cutout (WxH) 329 x 238mm 344 x 262mmXV-440-12TSB-1-5085 17 200875Weight approx. 4.1kg approx. 5.3kg approx. 4.5kg approx. 5.7kg-IP69KProtected against the ingress of water with highpressureand steamThe XV400 5.7“ with stainless steel front is designed for areaswhere highpressure cleaners are used such as in the food industry.The IP69K protection class even guarantees absolute watertightness in applications subject to frequent cleaning.XV-460-57TQB-1-50EX-Zone 1For use in explosive atmosphereXV400 10.4“ / 12.1“ with stainless steel front are designed foruse in areas where an explosive atmosphere consisting of amixture of air and flammable substances in the form of gas,vapor or mist is likely to occur in normal operation occasionally,such as in the chemical, pharmaceutical and food industryas well as in oil refineries. When integrated in pressurizedenclosures, this device meets the protection requirements forZone 1, category 2G EEx p.XV-440-10TVB-1-50XV-440-12TSB-1-5021


XV400HMI/PLC with touch displayXV40015“ color 15“ 15“ stainless steelFunctionHMI with optional PLCFront Standard Stainless steelInfra-red touch,safety glass, non-reflectiveResistive touch,glass, non-reflectiveXV-460-15TXB-1-1085 17 201000XV-460-15TXB-1-5085 17 201180- -Display TFT-LCD color 15“Resolution XGA 1‘024 x 768Number of usable colors 65‘536BacklightProcessorMemoryRetain memoryInternal Flash memoryOptional memory cardsOperating systemInterfaces onboard4 CCFL, dimmableRISC 32Bit, 400MHz64MB32kB1.5MB linear2 x CompactFlashWinCEEthernet, RS232, USB-Host, USB-Device, CANSlots for communication modules 2Rated valueProtection typeDimensions device (WxHxD)Mounting cutout (WxH)24VDCIP65 front,IP20 rear427 x 332 x 99mm410 x 315mmWeight approx. 6.2kg approx. 7.5kg1 CAN2 2 x USB Host3 USB Device4 Ethernet5 RS2326 2 x slot for communication module7 2 x CompactFlash22www.microinnovation.com


XVM400Mobile PanelThe control panel XVM400 is a portable display and operation panel for industrial applications. Already included in the delivery is theGalileo runtime. With this industrial proven visualization tool you can create in shortest time considerable sized and complex applications.Galileo is designed to work in every market segment and acts as an universal projecting environment for all Micro Innovation products.The Ethernet interface offers a high number of protocols to established control systems. Also the hardware is designed to cover anyeventuality that comes up: A robust concept of the panel and patented display guarantees a save fall from a height of up to 1.5m. Operation with the left and right hand, a good readable display, variable cable output, different holding possibilities, three-stepacknowledgement button, integrated emergency stop and a further 31 buttons that can be accessed directly in Galileo guaranteesa maximum of possibilities.XVM4006.5“ color XVM-430-65TVB-1-11 XVM-450-65TVB-1-11 XVM-410-65TVB-1-11FunctionFrontTouchHMIStandardResistiveDisplay TFT-LCD (color display) 6.5“ResolutionNumber of usable colorsBacklightOperation elementsProcessorMemory2 3-position enabling switches,twin circuit;temergency stop switch, twincircuitVGA 680x48065536 colors2 CCFL, dimmable2 3-position enabling switches,twin circuit;temergency stop switch, twincircuit;key switch, (3 positions);handwheelXscale PXA 270, 416 MHz64MB, 64 MB SDRAMOptional memory cards -Operating systemVisualization softwareInterfaces onboardWinCEGalileoEthernet, USB-Host, RS232Slots for communication modules -Rated valueProtection typeDimensions deviceWeight24VDCIP65Ø 250 mm, height 125 mmapprox. 1.3 kg2 3-position enabling switches,twin circuit;key switch, (3 positions);handwheelArticle no. 85 33 000000 85 33 000100 85 33 00005023


XVC100HMI-PLC with text displayThe XVC100 compact display PLC integrates an operator panel with text display and a powerful compact PLC in one device.This device concept offers a wide range of automation and networking options. A fully-fledged compact PLC with digital and analoginputs and outputs is integrated behind the membrane keyboard with an 8 x 20 character display. The integrated CAN bus allows theconnection of remote peripheral devices. All connectors can be accessed from the rear. The PLC is programmed in compliance with theIEC 61131-3 industrial standard, thus turning the XVC100 display PLC into a universal device for automation applications.A user-friendly PLC function library is available for the simple and efficient programming of visualization functions.XVC100monoFunctionFrontOperationDisplayActive display areaXVC-101-C192K-K82HMI - SPSStandardMembrane keyboardPassive Matrix Mono LC-Displayapprox. 71 x 39 mmResolution 128 x 64BacklightNumber of keysProcessorData / program memoryRetain memoryOptional memory cardI/Os onboardInterfaces onboardRated valueProtection typeDimensions device (WxHxD)WeightLED28, (9 with LED)c16656 kB / 384 kB8 kB1 x CompactFlash10 digital inputs8 digital outputs, 24 V/0,5 A8 digital inputs/outputs configurable2 analog inputs, 0 – 10 V/10 Bit2 analog outputs, +/-10 V/12 Bit2 counter inputs, 50 kHz2 interrupt inputs1 encoder inputs, 50 kHzCAN, RS23224VDCIP65 front, IP20 rear212 x 156 x 60 mmapprox. 0.9 kgArticle no. 85 23 200000DriveThe XVC100 provides the machineand system builder with a low-costdevice for a wide range of tasks whilststill offering the tried and tested featuresof the xSystem and the userfriendlyproject design features.The rugged and compact designenables applications that werepreviously impossible due to space orprice restrictions.24www.microinnovation.com


LicensingLicensing XV100, XV200, XVS400, XV400 and XP700The range of functions possible for each device is determined by means of license points that are uniquely assigned to the deviceconcerned. Additional license points can be assigned to the device by means of license product papers (see Accessories XV licenseproduct papers). Licensing is carried out via the Internet at www.microinnovation.com/license.Entering the license product paper and device series number on the web page provides you with the license code and a licenseconfirmation via email for your production documents. You enter the license code via the licensing menu on the device and thusincrease the number of internal license points on the device.Number of required license points depending on the required functionality:Runtime / Tools Onboard interface License pointsGALILEO-Runtime - 100EPAM-Runtime - 100 1)MXpro-Runtime - 100CE Telediag RS232 40S7 PG Router Ethernet and Profibus 80CAN Monitor CAN -DXS Remote (DXS communication) Ethernet 80Galileo Open (for XP700 / standard PC) - -License pointsCommunicationOnboard interfaceMXpro GALILEO EPAMProgramming access Ethernet 0 0 0CoDeSys-SYMArti local (GALILEO/EPAM MXpro) Local 0 0 0CoDeSys-SYMArti external Ethernet 0 40 0A.Bradley DF1 RS232 - 40 -A.Bradley EtherNet/IP Ethernet - 120 -Beckhoff TwinCAT ADS Ethernet - 80 -CANopen, Master CAN 0 - -CANopen, Device (Slave) CAN 0 40 -DXS Remote (DXS communication) Ethernet - 80 -Modbus TCP/IP Ethernet - 80 -Modbus RTU RS232 - 40 -Moeller easy800/MFD RS232 - 40 -Moeller Sucom A RS232 - 40 -Moeller Suconet K on XVH342-57SKS Suconet K - 0 -Profibus DP-Master (1,5 MBaud) Profibus 40 - -Siemens Industrial Ethernet Ethernet - 80 -Siemens MPI Profibus - 40 -Siemens PPI Profibus - 40 -Siemens S7 Profibus Standard Profile Profibus - 40 -Notes: 1) A LIC-HMI-EPAM-STD license product paper is required for the operation of EPAM runtime on XV400, XVS400 and XVH300 devices. Thesticker provided on the license product paper must be affixed to the device. Validation of the certificate via the Internet is unnecessary.Calculation of the required license pointsTo use the PLC function in accordance with the applicable license conditions, the device license must be extended explicitly using aspecific license product paper, see table „XV license product papers”. These license product papers contain a PLC license sticker whichmust be affixed to the device. Add the required license points for each of the external communication options you use. Communicationto several devices with the same protocol only has to be counted once. Deduct the number of points already on the device (e.g. 140)from the total. The resulting difference is the number of license points that must be added using the license product papers.25


LicensingValidating license product papersThe validation of license product paper couldn’t be simpler. Once you have entered the license product paper and the device seriesnumber on the Internet page www.microinnovation.com/license the license code is issued immediately for activating the devicefunctions required. After the license code is entered on the XV100, XV200, XVS400 or XV400 device, the additional license points areadded directly to the device.Note: You can find various licensing examples on our website www.microinnovation.com: Licensing - License Produkt Papers - Examples.26www.microinnovation.com


AccessoriesDescription Type / Article no. For use withWindows CE licensesWinCE 3.0 Standard runtime license with license stickerWinCE 5.0 Core runtime license with license stickerWinCE 5.0 Professional Plus runtime license with license stickerMemory cardsSD memory card, min. 128MB, without operating systemCompactFlash, min. 128MB, without operating systemCompactFlash, min. 128MB, bootable withWinCE 3.0, without WinCE licenseCompactFlash, min. 128MB, bootable withWinCE 5.0, without WinCE licenseXV license product paperLicense product paper 40 POINTSLicense product paper 80 POINTSLicense product paper 160 POINTSLicense product paper PLC with license sticker LIGHTLicense product paper PLC with license sticker SMALLLicense product paper PLC with license sticker MEDIUMCommunication modules for XV400 devicesMultiprotocol boardMultiprotocol board MPIProfibus DP-Master (12 MBaud)Profibus DP-Slave (12 MBaud)EIB (3release)Accessories for XVM400 (Mobile Panel)Wall holder for mobile panel incl. cable holderTerminal box mobile panel, outside control panel IP 65Cable set mobile panel 5mCable set mobile panel 10mCable set mobile panel 15mStrapping plug emergency switch mobile panelSpare Key, 2 piecesLIC-OS-CE3091 30 600000LIC-OS-CE50-C91 30 600005LIC-OS-CE50-PP91 30 600020MEMORY-SD-A1-550 61 000550MEMORY-CF-A1-S50 61 000400OS-FLASH-A1-S90 17 000060OS-FLAH-A1-C90 17 000070LIC-OPT-1ST-LEVEL91 30 000400LIC-OPT-2ND-LEVEL91 30 000420LIC-OPT-3RD-LEVEL91 30 000430LIC-OPT-MXP-LIGHT91 30 000050LIC-OPT-MXP-SMALL91 30 000100LIC-OPT-MXP-MEDIUM91 30 000110COM-MPB1-TP85 12 00009COM-MPB2-TP85 12 00004COM-DPM-MC285 12 000200COM-PDT-TP85 12 000008COM-EIB2-TP85 12 000011KETOP WB09585 33 001000KETOP CB21185 33 001003KETOP TT050 MV185 33 001001KETOP TT100 MV185 33 001002KETOP TT150 MV185 33 001006KETOP BC00185 33 001005KETOP EKY00185 33 001007XV-2..., XVS-4..., XV-4...XV-2..., XVS-4..., XV-4...XV-2..., XVS-4..., XV-4...XV-1...XV-2..., XVS-4..., XV-4...XV-2..., XVS-4..., XV-4...XV-2..., XVS-4..., XV-4...XV-1..., XV-2..., XVS-4...,XV-4...XV-1..., XV-2..., XVS-4...,XV-4...XV-2..., XVS-4..., XV-4...XV-2xx-57BAS,XV-2xx-57CNNXV-2xx-57MPN,XVS-4xx-57..., XVS-4xx-8...,XV-4xx-57..., XV-4xx-8...XVS-4xx-10..., XVS-4xx-12...,XV-4xx-10..., XV-4xx-12...XV-4...XV-4...XV-4...XV-4...XV-4...XVM-4...XVM-4...XVM-4...XVM-4...XVM-4...XVM-4...XVM-45x..., XVM-41x...27


AccessoriesDescription Type / Article no. For use withAdditional fixing bracketsAdditional fixing brackets for IP65Set of retaining brackets for mouinting the device(4 retaining brackets with threaded pin)ACCESSOIRES-HKS-IP6565 01 000002XVS-4xxxXV-4...BatteriesSpare batteriesDevice accessories (supplied with the device)Device accessories as replacement- 8 Retaining brackets for mounting the device- 8 Threaded pins for mounting the device- 1 Sealing strip for mounting the device- 1 Power supply connector- 1 Touch penACCESSOIRES-BAT01x45 60 000001ACCESSOIRES-TP-57-KG-183 17 000018XVC-1...XV-2...Device accessories as replacement- 1 Set of retaining brackets for mounting the device(4 retaining brackets with threaded pin)- 1 Sealing strip for mounting the device- 1 Power supply connector- 1 Touch penACCESSOIRES-TP-57-RES-183 17 000001XVS-4xx-57...XV-4xx-57...Device accessories as replacement- 2 Set of retaining brackets for mounting the device(4 retaining brackets with threaded pin)- 1 Sealing strip for mounting the device- 1 Power supply connector- 1 Touch penACCESSOIRES-TP-10/12-RES-183 17 000007XVS-4xx-10...XVS-4xx-12...XV-4xx-10...XV-4xx-12...List of the most common protocols:ProtocolEIB (3rd release)Matushita FP SeriesMitsubishi A-Serie / F-SeriesMoeller SuconetOmron C- H- K-SeriesTelemecanique Unitelway newProfibus DP-Master (12MBaud)Profibus DP-Slave (12MBaud)Siemens MPIRequired communication module for the XV400 devicesCOM-EIB2-TPCOM-MPB1-TP / COM-MPB2-TPCOM-MPB1-TP / COM-MPB2-TPCOM-MPB1-TP / COM-MPB2-TPCOM-MPB1-TP / COM-MPB2-TPCOM-MPB1-TP / COM-MPB2-TPCOM-DPM-MC2COM-PDP-TPCOM-MPB2-TP28www.microinnovation.com


Remote I/O SystemsxSystemNWhether controlling motion, temperature or speed measurement, current and tensionrecording – the fields of usage for remote I/Os are so wide ranging as are the differenttypes of applications. They are everywhere in usage where decentral signal processing isthe beginning and end of the automation concept.Micro Innovation offers for every application the suiting I/O system. Whether fine granulargraded with XI/ON or compact with WINbloc – naturally also in mix operation in onbus thread.The result: a modular concept with easy to use handling – adaptable to any application,intelligent and future proof.29


XI/ONRemote I/O System - DescriptionSystem configuration XI/ONDesign your XI/ON station simply with the “I/O Assistant” software, which can be downloaded for free from our Website:www.microinnovation.com -> Downloads -> Software -> I/Oassistant.Benefits of the I/Oassistant: A complete parts list is generated automatically for your order Menu item [Station] > [Verify] allows an easy verification tof the configuratedstationA XI/ON station can consist of the gateway and a maximum of 74 modules in slicedesign (corresponds to a 1 m mounting rail length, including end brackets and endplate). When modules in block design are used, the maximum number of modulesis reduced accordingly (1 module in block design is equivalent to about 8 modulesin slice design).For the maximum system configuration, the use of a sufficient number of busrefreshing and power feeding modules must be taken into account.Maximum system configurationModule typeChannelsmax. no. / StationCANopenModulesmax. no. / StationChannelsmax. no. / StationDeviceNetDigital inputs, 4 DI 288 72 2) 288 72 2)Digital outputs, 4 DO 288 72 2) 288 72 2)Analog inputs, 2 AI-I 142 71 1) 142 71 3)Analog inputs, 2 AI-U 142 71 1) 142 71 3)Analog inputs, 2 AI-PT/NIor 2 AI-THERMO142 71 1) 126 63 3)Analog outputs, 2 AO-I 142 71 1) 126 63 3)Analog outputs, 2 AO-U 142 71 1) 126 63 3)Counter module, 1 CNT 71/71 71 1) 31/31 31 1)Maximum station configuration,dependent on process dataPROFIBUS-DPModulesmax. no. / StationMaximum station configuration,dependent on diagnostics dataDigital inputs, 4 DI 288 72 2) 4) 2) 4)288 72Digital outputs, 4 DO 288 72 2) 4) 2) 4)288 72Analog inputs, 2 AI-I 78 39 2) 4) 2) 4)78 39Analog inputs, 2 AI-U 78 39 2) 4) 2) 4)78 39Analog inputs, 2 AI-PT/NI 46 23 3) 4) 3) 4)46 23Analog inputs, 2 AI-THERMO 76 38 2) 4) 2) 4)58 29Analog outputs, 2 AO-I 38 19 3) 5) 3) 5)38 19Analog outputs, 2 AO-U 38 19 3) 5) 3) 5)38 19Counter module, 1 CNT 7/7 7 3) 4) 3) 4)7/7 71)plus 1 bus refreshing module2)plus 2 bus refreshing modules3)plus 3 bus refreshing modules4)Standard GSD file: unpacked module representation5)Typified GSD file: unpacked module representation30www.microinnovation.com


XI/ONRemote I/O System - Selection Guide1) Base modules for gateway powersupply2) Base modules for bus refreshingwithin the stationECO GatewaysXNE-GWBR-PBDPXNE-GWBR-CANOPENXNE-GWBR-2ETH-IPECO Digital InputsXNE-8DI-24VDC-DXNE-16DI-24VDC-PECO Digital OutputsXNE-8DO-24VDC-0.5A-PXNE-16DO-24VDC-0.5A-PECO Multi Function ModulesXNE-8AI-U/I-4PT/NIXNE-4AO-U/IECO Technology ModulesXNE-2CNT-2PWMXNE-1SWIREGatewaysXN-GWBR-PBDPXN-GWBR-CANOPENXN-GWBR-DNETXN-PLC-CANOPENDigital InputsXN-2DI-24VDC-PXN-2DI-24VDC-NXN-2DI-120/230VAC-PXN-4DI-24VDC-PXN-4DI-24VDC-NXN-16DI-24VDC-PXN-32DI-24VDC-PDigital OutputsXN-2DO-24VDC-2A-PXN-2DO-24VDC-0,5A-PXN-2DO-120/230VAC-0,5A-PXN-2DO-24VDC-0,5A-NXN-4DO-24VDC-0,5A-PXN-16DO-24VDC-0,5A-PXN-32DO-24VDC-0,5A-PRelay ModulesXN-2DO-R-NCXN-2DO-R-NOXN-2DO-R-COAnalog InputsXN-1AI-I(0/4...20MA)XN-2AI-I(0/4...20MA)XN-1AI-U(-10/0...+10VDC)XN-2AI-U(-10/0...+10VDC)XN-4AI-U/IXN-2AI-PT/NI-2/3XN-2AI-THERMO-PIAnalog OutputsXN-1AO-I(0/4...20MA)XN-2AO-I(0/4...20MA)XN-2AO-U(-10/0...+10V)Technology ModulesXN-1CNT-24VDCXN-1RS232XN-1RS485/422XN-1SSIPower Supply ModulesXN-BR-24VDC-DXN-PF-24VDC-DXN-PF-120/240VAC-D2)1)2)1)no base modules requiredno base modules requiredno base modules requiredno base modules requiredno base modules requiredno base modules requiredno base modules requiredBase ModulesXN-P4x-SBBC-BXN-P4x-SBBCXN-P3x-SBB-BXN-P3x-SBBXN-B6x-SBCSBCXN-B6x-SBBSBBXN-B4x-SBBCXN-B3x-SBCXN-B3x-SBBXN-S6x-SBCSBCXN-S4x-SBBS-CJXN-S6x-SBBSBBXN-S4x-SBCSXN-S4x-SBBSXN-S4x-SBBCXN-S3x-SBCXN-S3x-SBB31


XI/ONRemote I/O SystemGeneral technical dataStandards DIN 19245EN 61131DIN IEC 68-2EN 50082-2Supported fieldbus systemsPotential isolationAmbient temperatureAmbient temperature, storageRelative air humidityHarmful gasSO 2H 2SPROFIBUS-DP, CANopen, DeviceNetYes, via optocouplers0...55°C-25...85°CVibration resistance, operating conditions To IEC/EN 61131Shock resistance To IEC 60068-2-27Repetitive shock resistance To IEC 60068-2-295...95% (indoor), Level RH-2, no condensation (at 45°C for storage)10ppm (relative humidity < 75%, no condensation)1.0ppm (relative humidity < 75%, no condensation)Tipping and falling To IEC 60068-2-31, free fall to IEC 60068-2-32Protection typeElectromagnetic compatibility (EMC)ESD EN 61131-2Electromagnetic fields EN 61131-2Burst EN 61131-2Surge EN 61000-6-2HF asymmetric EN 61000-6-2Radiated interference / conducted interference EN 61000-6-4Radiated interference (radiated, high frequency) EN 61000-6-4Type Test To EN 61131-2Base modulesRated data To VDE 0611 Part 1/8.92 / IEC 947-7-1/1989Connections in TOP directionSpring-loaded/screw terminalStripping length8 mmTerminal capacitySinge conductor H07V-U 1.5mm 2Singe conductor H07V-K 0.5...2.5mm 2Flexible with ferrule 0.5...1.5mm 2Plug gauge IEC/EN 60947-1A1ApprovalsCE, UL and CSAIP20XI/ON ECO Gateways XI/ON ECO Modules (up to 16 DI/DO on 12,5 mm) - Free combinable to max. 4x PT/NI- Every channel parameterable in currentrespectively tension ranges- Wire breakage signalization for every input - Every channel parameterable in currentrespectively tension ranges - 2 Counter signals and- 2 PWM signals32www.microinnovation.com


XI/ON ECORemote I/O SystemECO Gateways XNE-GWBR-PBDP XNE-GWBR-CANOPEN XNE-GWBR-2ETH-IPFieldbus PROFIBUS-DP CANopen EthernetProtocol DPV0 / DPV1 CANopen Ethernet IPSystem supply U sysV DC 24 V DCpermissible range 24 V DC U sysV DC 18...30Field voltage U L24Permissible range V DC 18...30Ripple % < 5(EN 61131-2)Service interface PS/2 socket Mini USBConnections, fieldbusPush-In tension clamp terminalData transmission rate kBit/s 9.6...12000 20...1000 10‘000 / 100‘000Selecting the data transmission rate automatic via DIP switch orautomaticautomaticAddressing über DIP-Schalter via DIP switch, DHCO, BootPor PGMAddress range 0...125 1...63 1...254Fieldbus termination via DIP switch -Number of parameter bytes Max. 235 Byte -Number of diagnostics bytesDPV0: Max. 64 Byte (61 for-module diagnostics + 3 Bytegateway diagnostics)DPV1: Max. 240 ByteArticle no. 85 50 107592 85 50 107591 available from2nd quarter 2010 onwardsECO Digital inputs XNE-8DI-24VDC-P XNE-16DI-24VDC-PChannels No. 8 16Nominal voltage on supply terminal U L24 V DCNominal current drawn from supplyterminalI LmA 1.5 mA 13mANominal current drawn from modulebusI MBmA 15 mAInsulation test voltage U iV AC -Power loss W < 1.5 < 2.5Input voltageInput voltage nominal value V DC 24 V DCLow signal U L-U L...+5 VHigh signal U H11 V...U LFrequency range Hz -Input currentLow signal / active signal I L-1 mA...1.5mAHigh signal / active signal I H2 mA...5 mAInput delayt rising edgeμs < 100 < 150t falling edgeμs < 200 < 300Max. permissible cable capacitance -Article no. 85 50 100794 85 50 10143933


XI/ON ECORemote I/O SystemECO Digital Outputs XNE-8DO-24VDC-0.5A-P XNE-16DO-24VDC-0.5A-PChannels No. 8 16Nominal voltage on supply terminal U L24 VCDNominal current drawn from the supplyterminal (at load current = 0 mA)Nominal current drawn from modulebusI LmA 3 mAI MBmA 15 mA 25 mAInsulation test voltage -Power loss W normally 1.5 normally 2.5Output voltageHigh signal U H/U AU L...1 V DCOutput currentHigh signal (nominal value) I H0.5 AHigh signal (permissible range) I HA 1.0Low signal I AmA -Delay on signal change and resistive loadfrom Low to High μs < 300from High to Low μs < 300Load resistance range -Utilization factor g % 100 50%, max. 4Connectable equipmentresistive loads, inductive loads, lamp loadsResistive load O ≥ 48Inductive load H to DC13 in accordance with IEC 60947-5-1Lamp load R LLW ≤ 6Switching frequencyWith resistive load f Hz < 100With inductive load Hz to DC13 in accordance with IEC 60947-5-1With lamp load Hz < 10Number of diagnostics bits -Diagnostics -Short-circuit proof to EN 61131-2Restart after short-circuit rectified l iautomaticArticle not. 85 50 100795 85 50 101438yesXI/ON ECO Modules - More information where space is at a premiumSave space and costs with XI/ON ECO I/O modules. The XI/ON remote I/O systemhas been expanded with the new price and space optimized XI/ON ECOI/O modules. Depending on type, 8 or 16 inputs andoutputs can be connected over a width of only 12.5 mm.The high connection density reduces the mounting widthfor typical applications. All modules are implemented withan integrated connection level.12,5 mmKey benefits of the XI/ON ECO modules at a glance: connention level time required for mounting 16 inputs oroutputs34www.microinnovation.com


XI/ON ECORemote I/O SystemECO Multi Function ModuleXNE-8AI-U/I-4PT/NIChannels No. 8 (U/I) / 4 (PT/NI/R)Nominal voltage on supply terminal U L24 V DCNominal current drawn from the I LmA normally 35supply terminalNominal current drawn from module I MBmA < 30busPower loss W normally < 1.5 WAdjustable measured variablevoltage, current, PT, NI, RVoltage meteringMeasuring ranges-10…10 VDC / 0…10 V DCMeasured value representationStandard, 16 Bit / 12 Bit (flush-left)Extended Range, 16 Bit / 12 Bit (flush-left)PA (NE43), 16 Bit / 12 Bit (flush-left)Capability of connecting2-wireMaximum input voltage U maxV DC ±20Input resistance (burden) R LkΩ > 200Limit frequency f GHz 1.5Basic error limit at 23° C % 0.2Temperature coefficient200 ppm/°CCurrent measuringMeasuring ranges0…20 mA / 4…20 mAMeasured value representationStandard, 16 Bit / 12 Bit (flush-left)Extended Range, 16 Bit / 12 Bit (flush-left)PA (NE43), 16 Bit / 12 Bit (flush-left)Capability of connecting2-wireMaximum input current Imax mA 40Maximum input voltage U maxV DC < 17Input resistance (burden) R LΩ < 52Limit frequency f GHz 1.5Basic error limit at 23° C % 0.2Temperature coefficient200 ppm/°CTemperature measuringPlatin sensors (EN 60751)PT100, PT200, PT500, PT1000Nickel sensorsNI100, NI1000 (DIN 4343760), NI1000TK5000Measuring ranges PT100, PT200,-200…850 °C / -200…150 °CPT500, PT1000 (2-/3-wire)Measuring ranges NI100, NI1000,-60…250 °C / -60…150 °CNI1000TK5000 (2-/3-wire)Measured value representationStandard, 16 Bit / 12 Bit (flush-left)Capability of connecting2-/3-wireMeasurement current I mess< 0.5 mA (Integral)Limit frequency f GHz 1.5Basic error limit % PT100, NI100: 0.5%PT200, PT500, PT1000, NI1000, NI1000TK5000: 0.2%Temperature coefficient200 ppm/°CR (resistance measurement)Measuring ranges0…250 W, 0…400 W, 0…800 W, 0…2000 W, 0…4000 WMeasured value representationStandard, 16 Bit / 12 Bit (flush-left)Capability of connecting2 LeiterLimit frequency f GHz 1.5Basic error limit at 23° C % 0.2Temperature coefficient200 ppm/°CNumber of diagnostics bytes 4Number of parameter bytes 8Article no. 85 50 10079935


XI/ON ECORemote I/O SystemECO Multi Function ModulesXNE-4AO-U/IChannels No. 4 (U/I)Nominal voltage on supply terminal U L24 V DC (18...30 V DC)Nominal current drawn from the supply terminalwithout signal output I LmA < 40with signal output I LmA < 150Nominal current drawn from module I MBmA < 40busPower loss W normally < 3 WAdjustable measured variablevoltage, currentOutput parameter, voltageOutput voltage-10…10 VDC / 0…10 V DCMeasured value representationStandard, 16 Bit / 12 Bit (flush-left)Extended Range, 16 Bit / 12 Bit (flush-left)PA (NE43), 16 Bit / 12 Bit (flush-left)Capability of connecting2-wireLoad resistanceResistive load Ω > 1000Capacitive load μF < 1Transmission frequency Hz < 20Recovery timeResistive load ms < 1Inductive load ms < 2Capacitive load ms < 2Short-circuit current mA < 40Basic error limit at 23° C % 0.2Temperature coefficient200 ppm/°COutput parameter, currentOutput current0…20 mA / 4…20 mAMeasured value representationStandard, 16 Bit / 12 Bit (flush-left)Extended Range, 16 Bit / 12 Bit (flush-left)PA (NE43), 16 Bit / 12 Bit (flush-left)Capability of connecting2-wireLoad resistanceResistive load Ω < 450Capacitive load μF < 1Transmission frequency Hz < 20Recovery timeResistive load ms < 1Inductive load ms < 2Capacitive load ms < 2Short-circuit current mA < 40Basic error limit at 23° C % 0.2Temperature coefficient200 ppm/°CNumber of parameter bytes12 ByteArticle no. 85 50 10079336www.microinnovation.com


XI/ON ECORemote I/O SystemECO Technology ModuleCounter moduleXNE-2CNT-2PWMChannels No. 2Nominal voltage on supply terminal U L24 V DCNominal current drawn from the I LmA ≤ 50supply terminalNominal current drawn from module I MBmA ≤ 50busPower loss W < 3Power supply of encodersOutput voltage U L+ (-0.8 V) / GND LDigital inputInput voltageInput voltage nominal value V DC 24Low signal U L-30 V DC...5 V DCHigh signal U H11 V DC...30 V DCInput currentLow signal I L-8 mA...1.5 mAHigh signal I H2 mA...10 mAMinimum pulse width μs Filter on: > 25 ms (20 kHz)Filter off: < 2.5 ms (200 kHz)Digital outputChannels No. 4Output voltageOutput voltage nominal value V DC 24Low signal U L≤ 3 V DCHigh signal ≥ L+ (-1 V)Output currentHigh signal (permissible range) I H5 mA...0.6 AHigh signal (nominal value) I H≤ 0.5 A (55° C)Switching frequency2 PWM 20 kHz2 DO 100 HzOutput delay PWM25 μs (resistive load)Short-circuit proofyesMeasuring rangesFrequency0.1 Hz...200 kHzPeriod duration5 ms...120 sCounter modesSignal evaluation A, BPulse and direction, rotary encoder single/double/quadrupleModeendless, once only, periodic countSynchronisationonce only / periodicCount limitsUpper count limit: 0...7FFF FFFFLower count limit: 8000 0000...FFFF FFFFNumber of diagnostics bytes 4Number of parameter bytes 16Article no.available from 2nd quarter 2010 onwards37


XI/ON ECORemote I/O SystemECO Technology ModulesXNE-1SWIRESupplyModule bus voltage4.75...5.25 VCurrent module bus60mAVoltage field18...30 VCurrent field (LIN phases on full load)600 mASupply of contactors18...30 V DCSupply current of contactors3 ASWIRE interfaceNumber of SWIRE phase leads 1Max. number of XNE-1SWIRE modulesper XN station4 Profibus32 CAN / DeviceNetMax. number of SWIRE nodes per line 16Number of diagnostics bits 4Data per SWIRE nodeSupply of SWIRE nodes (short-circuitproof)Max. supply current of all LIN nodes(short-circuit proof)InsulationPotential isolation(module bus U SW/ U AUX↔ U L)max. 4I / 4Q17 V DC500 mAV rms500Potential isolation (U SW↔ U AUX) V rmsNoneClimatic conditionsAmbient temperature 0...55 °CStorage temperature -25...85 °CAir humidity (no condensation) 5...95%Protection typeArticle no. 85 50 107590IP20Smart WireDirect networking of Moellermotor starter in the XI/ON systemXI/ON Interface for easyConnect SmartWire from MoellerThe tried and tested XI/ON system has now been expanded with the SmartWire interface slice module. In addition to a number ofdifferent inputs and outputs, this also allows standard Moeller motor starters and contactors to be connected directly to XI/ON.■ 4 Profibus or 32 CAN / DeviceNet lines perXI/ON station■ 16 nodes per line■ Simple configuration by means of pushbutton■ Autodetect function38www.microinnovation.com


Decentralized peripheral devicesThe decentralized structure of automation systems is an essential element of state-of-the-art automation concepts.The modular design of the application is also becoming increasingly important in addition to the distribution of digital and analog I/Opoints. Decentralized preprocessing via intelligent gateways relieves the processing requirements of the central controller. Distributedintelligence makes automation systems faster, more reliable and more affordable.Conventional solution with remote I/OXI/ON can be connected to a wide range of controllers as ahighly granular decentralized I/O system.Distributed intelligence with XI/ON PLCThe programmable CANopen gateway now brings PLC performancedirectly to the fieldbus terminal. The device is idealfor decentralized automation concepts and for relieving theprocessing load on the higher-level PLC.XI/ON PLC as a flexible compact controllerThe intelligent gateway can also be used as a stand-alonespace-optimized PLC and connected to remote stations.39


XI/ONRemote I/O SystemGateways with busrefreshXN-GWBR-PBDPXN-GWBR-CANOPENXN-GWBR-DNETXN-GWBR-MODBUS-TCPXN-PLC-CANOPENFieldbus PROFIBUS-DP CANopen DeviceNet Modbus TCP CANopenSystem supply U sysV DC 24 V DC/5 V DCPermissible range 24 V DC U sysV DC 18...30Field voltage U L24Permissible range V DC 18...30Ripple % < 5 (EN 61131-2)Service interfaceConnections fieldbus1 x SUB-D connector,9-pinOpen StyleConnectorData transmission rate kBit/s 9.6...12000 20, 50, 125,250, 500, 800,1000PS/2 socketOpen StyleConnectorRJ45Open StyleConnector125, 250, 500 10/100 MBit/s 20, 50, 125,250, 500, 800,1000Selecting the data transmission rate - via DIP switch automatic SoftwareAddressing 2 rotary coding switches Coding switch,BootIP, DHCPSoftwareFieldbus termination external automatic externalNumber of parameter bytes 5 Bytes -Number of diagnostics bytes 3 Bytes -Address range 1...99 dec. 1...63 dec. 1...4‘162‘314‘256 1...127 dec.Program code / Program data kByte - 128 / 128Cycle time 1k instruction ms - 0.5Real-time clock - YesArticle no. 85 50 270324 85 50 270325 85 50 270326 85 50 289792 85 50 274124GatewaysXN-GW-PBDP-1.5MBXN-GW-PBDP-12MBXN-GW-PBDP-12MB-STDXN-GW-CANOPENXN-GW-DNETFieldbus PROFIBUS-DP CANopen DeviceNetOperating voltage V DC 5 (from bus refreshing module)Permissible range V DC 4.7...5.3Ripple % < 5 (nach EN 61131-2)Nominal current drawn from modulebusI MBmA ≤ 430 ≤ 410 ≤ 350 ≤ 250Service interface PS/2 socket PS/2 socket onlyfor firmwaredownloadConnections fieldbus2 x SUB-D connectors,9-pin;2 x springloadedterminalstrips for directwiring1 x SUB-D connector, 9-pin 1 x SUB-D connector,9-pin;1 x SUB-D connector,9-pin;2 x direct wiring,5-pin, springloadedData transmission rate kBit/s 9.6...1500 9.6...1200 9.6...1500 20, 50, 125, 250,500, 800, 1000PS/2 socketSelecting the data transmission rate - via DIP switchOpen StyleConnector125, 250, 500Addressing 2 hex rotary coding plugs 2 rotary coding switches 2 dec. codingswitchesFieldbus termination via SUB-D connector via DIP switchNumber of parameter bytes 5 Bytes -Number of diagnostics bytes 3 Bytes -Address range 1...125 dec. 1...127 dec. 0...63 dec.Article no. 85 50 225162 85 50 225161 85 50 229499 85 50 225163 85 50 22516440www.microinnovation.com


XI/ONRemote I/O SystemDigital Inputs XN-2DI-24VDC-P XN-2DI-24VDC-N XN-2DI-120/230VACChannel No. 2Nominal voltage on supply terminal U L24 V DC 120/230 V ACNominal current drawn from supplyterminalNominal current drawn from modulebusI LmA ≤ 20I MBmA ≤ 28Insulatin test voltage U iV AC - 1780Power loss W 0.7 1Input voltageInput voltage nominal value V DC 24 V DC 120/230 V ACLow signal U L-30...5 V 0...5 V 0...20 V ACHigh signal U H11...30 V > (U PF-11 V) 79...265 V ACFrequency range Hz - 48...63Input currentLow signal / active signal I L0...1.5mA 1.8...10mA 0...1mAHigh signal / active signal I H2...10 mA 0...1.7 mA 3...8 mAInput delayt rising edgeμs < 200 < 20000t falling edgeμs < 200 < 20000Maximum permissible cable capacitanceBase moduleswithout C connectionwith C connection- 141 nF at 79 V AC/50 Hz;23 nF at 265 V AC/50 Hz2- / 3-wireXN-S3x-SBB2-wire proximity switches (Bero®) can be attached, with apermissible quiescent current up to 1.5mA4-wireXN-S4x-SBBC2- / 3-wireXN-S3x-SBBArticle no. 85 50 225169 85 50 225170 85 50 225171Openness supports the CANopen,Profibus-DP, DeviceNet andEthernet fieldbus systems for any busEthernetService interface also without head-end controller 41


XI/ONRemote I/O SystemDigital Inputs XN-4DI-24VDC-P XN-4DI-24VDC-N XN-16DI-24VDC-P XN-32DI-24VDC-PChannel No. 4 16 32Nominal voltage on supply terminal U L24 V DCNominal current drawn from supplyterminalNominal current drawn from modulebusI LmA ≤ 40 ≤ 30I MBmA ≤ 28 ≤ 45 ≤ 30Insulatin test voltage U iV AC -Power loss W 1 2.5 4.2Input voltageInput voltage nominal value V DC 24 V DCLow signal U L-30...5 V 0...5 V -30...5 VHigh signal U H15...30 V > (U PF-11 V) 15...30 VFrequency range Hz -Input currentLow signal / active signal I L0...1.5 mA 1.3...6 mA 0...1.5 mA < 1.5 mAHigh signal / active signal I H2...10 mA 0...1.2 mA 2...10 mA 2...10 mAInput delayt rising edgeμs < 200t falling edgeμs < 200Maximum permissible cable capacitanceBase moduleswithout C connection2- / 3-wireXN-S4x-SBBS4-wireXN-S6x-SBBSBB-2- / 3-wireXN-B3x-SBBwith C connection - 4-wireXN-B4x-SBBC2- / 3-wireXN-B6x-SBBSBBArticle no. 85 50 225165 85 50 225172 85 50 229434 85 50 230879-XI/ON standard modules 42www.microinnovation.com


XI/ONRemote I/O SystemDigital OutputsXN-2DO-24VDC-0.5A-PXN-2DO-24VDC-0.5A-NChannels No. 2XN-2DO-24VDC-2A-PXN-2DO-120/230VAC-0.5ANominal voltage on supply terminal U L24 VCD 120/230 V ACNominal current drawn from the supplyterminal (at load current = 0 mA)Nominal current drawn from modulebusI LmA ≤ 20 ≤ 50 ≤ 20I MBmA ≤ 32 ≤ 33 ≤ 35Insulation test voltage -Power loss W normally 1Output voltageHigh signal U H/U Amin. L+ (-1 V) max. GND (+1 V) min. L+ (-1 V) > U L(-2 V)Output currentHigh signal (nominal value) I H0.5 A 2 0.5 AHigh signal (permissible range) I HA < 0.6 < 2.4 0.02...0.5Low signal I AmA - < 1.5Backup fuse - 500 mA FFSurge current I SA - 8(1 period at 60 Hz)Number of outputs that can be switchedin parallelmax. -Total module current A -Delay on signal change and resistive loadfrom Low to High μs < 100 < T/2 +1 msfrom High to Low μs < 100 < T/2 +1 msLoad resistance range 48 Ω...1 kΩ - 12 Ω...1 kΩ at 120 VAC:240 Ω...6 kΩat 230 VAC:460 Ω..11.5 kΩUtilization factor g % 100Connectable equipmentResistive loads, inductive loads, lamp loadsResistive load O ≥ 48 ≥ 12 ≥ 48Inductive load H ≤ 1.2Lamp load R LLW ≤ 3 ≤ 12 ≤ 6 -Switching frequencyWith resistive load f Hz 5000 (R LO< 1kΩ) 100 (R LO< 1kΩ) 5000 (R LO< 1kΩ) -With inductive load Hz 2 -With lamp load Hz ≤ 10Number of diagnostics bits 2 0Diagnostics -Short-circuit proof to EN 61131-2 -Restart after short-circuit rectified l i-Base moduleswith C connection2- / 3-wireXN-S3x-SBC4-wireXN-S4x-SBCSArticle no. 85 50 225166 85 50 225174 85 50 225168 85 50 26569743


XI/ONRemote I/O SystemDigital Outputs XN-4DO-24VDC-0.5A-P XN-16DO-24VDC-0.5A-P XN-32DO-24VDC-0.5A-PChannels No. 4 16 32Nominal voltage on supply terminal U L24 VCDNominal current drawn from the supplyterminal (at load current = 0 mA)Nominal current drawn from modulebusI LmA ≤ 25 ≤ 30I MBmA ≤ 30 ≤ 45 ≤ 50Insulation test voltage -Power loss W normally 1 normally 4 normally 5Output voltageHigh signal U H/U Amin. L+ (-1 V)Output currentHigh signal (nominal value) I H0.5 AHigh signal (permissible range) I HA 1.0 A for max. 5 minutes < 0.6 1.0Low signal I AmA -Backup fuse -Surge current I SA -Number of outputs that can be switchedin parallelmax. - 2Total module current A - 10Delay on signal change and resitive loadfrom Low to High μs < 250 < 100 < 300from High to Low μs < 250 < 100 < 300Load resistance range 48 Ω...1 kΩ - 48 Ω...1 kΩUtilization factor g % 100 see Total module currentConnectable equipmentResistive loads, inductive loads, lamp loadsResistive load O ≥ 48Inductive load H ≤ 1.2 Category DC 13 toEN 60947-5-1Lamp load R LLW ≤ 6 ≤ 3 ≤ 6Switching frequencyWith resistive load f Hz 5000 (R LO< 1kΩ) 100 (R LO< 1kΩ) 100 (R LO< 1kΩ)With inductive load Hz 2 -With lamp load Hz ≤ 10Number of diagnostics bits 1 4 8Diagnostics - jaShort-circuit proof to EN 61131-2 - jaRestart after short-circuit rectified l i- automaticBasemoduleswith C connection4-wireXN-S4x-SBCS4 x 2- / 3-wireXN-S4x-SBCSBC2- / 3-wireXN-B3x-SBC≤ 1.22- / 3-wireXN-B6x-SBCSBCArticle no. 85 50 230880 85 50 229433 85 50 28979044www.microinnovation.com


XI/ONRemote I/O SystemRelay Modules XN-2DO-R-NC XN-2DO-R-NO XN-2DO-R-COContact type 2 break contacts 2 make contacts 2 changeover contacts,isolatedNominal voltage on supply terminal U L24 V DCNominal current drawn from supplyterminalNominal current drawn from modulebusI LmA ≤ 20I MBmA ≤ 28Insulation test voltage U iV AC 1780Power loss W Normally 1Connectable equpimentNominal load voltageOutput current per channel/230 V ACResistive loads, inductive loads, lamp loads230 V AC, 30 V DCmax. continuous current A 2max. continuous current, resistiveload5 A, load-dependentMinimum load current mA 10 mA at ≥ 12 V DCOutput current for DC voltage(resistive)Load limit curveUtilization factor g % 100Lifespan at 230 V ACat 5 A Operations x 10 6 > 0.1at 0.5 A Operations x 10 6 > 1Base moduleswithout C connectionwith C connection4-wireXN-S4x-SBBS4-wireXN-S4x-SBCSArticle no. 85 50 225175 85 50 225176 85 50 225167-Programmable CANopengatewayThe programmable CANopen gatewaybrings PLC performance directly to thefieldbus terminal.The device is ideal for decentralizedautomation concepts and for relievingthe processing load on the higher-levelPLC.Programming or online commissioningcan be carried out via the integratedservice interface or with networkedsystems via the CANopen fieldbus.The device can also be used as astand-alone space-optimized PLC andconnected to remote XI/ON stations.45


XI/ONRemote I/O SystemAnalog InputsXN-1AI-I(0/4...20MA)XN-2AI-I(0/4...20MA)XN-1AI-U(-10/0...+10VDC)XN-2AI-U(-10/0...+10VDC)Channels No. 1 2 1 2Nominal voltage on supply terminal U L24 V DCNominal current drawn from supplyterminalNominal current drawn from modulebusI LmA ≤ 50 ≤ 12 ≤ 50 ≤ 12I MBmA ≤ 41 ≤ 35 ≤ 41 ≤ 35Power loss W < 1Inpurt current mA 0/4...20 -Maximum input current mA 50 -Input voltage - -10/0...+10 VDCMaximum input voltage V DC - 35 V continuousInput resistance < 125 Ω ≥ 98.5 kΩLimit frequency (-3 db) Hz 200 > 50 200 > 50Offset error % ≤ 0.1Linearity % 0.03 - 0.03 -Basic error limit at 23 °C % < 0.2Repetition accuracy (deviation) % 0.09 0.05Temperature coefficient 300 ppm/°C of full scale value 150 ppm/°C of fullscale valueResolution of A/D converterMeasuring principleMeasured value representationTransmitter supply14 Bit (signedinteger)successive approximation16 Bit 14 Bit (signedinteger)Delta Sigma16 Bit signed integer12 Bit full range, flush-leftlinked to L+ and L- ofthe supply; not shortcircuitproof≤ 250 mA; linkedto L+ and L- of thesupply; not shortcircuitproofCycle time ms -Connectable sensors -successive approximation16 Bit signed integer12 Bit signed integerflush-left12 Bit full rangeflush-leftlinked to L+ and L- ofthe supply; not shortcircuitproof16 BitDelta Sigma16 Bit signed integer12 Bit full rangeflush-left≤ 250 mA; linkedto L+ and L- of thesupply; not shortcircuitproofNumber of diagnostics bits 2 Bit 1 Bit 2 BitNumber of parameter bits 3 Bit 1 Byte (per channel) 3 Bit 2 ByteBase moduleswithout C connectionwithout C connection, for transmittersupply2- / 3-wireXN-S3x-SBB4-wireXN-S4x-SBBSArticle no. 85 50 225177 85 50 230869 85 50 225178 85 50 23087046www.microinnovation.com


XI/ONRemote I/O SystemAnalog Inputs XN-4AI-U/I XN-2AI-PT/NI-2/3 XN-2AI-THERMO-PIChannels No. 4 2Nominal voltage on supply terminal U L24 V DCNominal current drawn from supplyterminalNominal current drawn from modulebusI LmA ≤ 20 ≤ 30I MBmA ≤ 50 ≤ 45Power loss W < 1Inpurt current mA 0/4...20 -Maximum input current mA 50 -Input voltage -10/0...+10 V DC -Maximum input voltage V DC 35 V continuous -Input resistance < 62 Ω / > 98.5 Ω -Limit frequency (-3 db) Hz 20 -Offset error % ≤ 0.1Linearity % 0.05 < 0.1 0.1Basic error limit at 23 °C % < 0.3 < 0.2Repetition accuracy (deviation) % 0.05Temperature coefficient300 ppm/°C of full scale valueResolution of A/D converter 16 Bit -Measuring principle Delta Sigma -Measured value representation16 Bit signed integer12 Bit full range flush-leftTransmitter supply -Cycle time ms - < 130 per channel 60 per channel + 100Connectable sensors - Platinum sensors: PT100,PT500, PT1000 (to DIN IEC751)Nickel sensors: Ni100,Ni1000 (to DIN 43760)Number of diagnostics bits - 2 Byte ( 1 Byte pro Kanal)DiagnosticsyesThermocouple types B, E, J,K, N, R, S, T to DIN IEC 584,class 1, 2, 3Number of parameter bits - 4 Bytes (2 Bytes per channel) 2 Bytes (1 Byte per channel)Base moduleswithout C connectionwithout C connection, for transmittersupply2- / 3-wireXN-S6x-SBCSBC2- / 3-wireXN-S3x-SBB- 4-wireXN-S4x-SBBS-4-wire with integrated coldjunction compensationXN-S4x-SBBS-CJArticle no. 85 50 289162 85 50 225181 85 50 22518247


XI/ONRemote I/O SystemAnalog Outputs XN-1AO-I(0/4...20MA) XN-2AO-I(0/4...20MA) XN-2AO-U(-10/0...+10VDC)Channels No. 1 2Nominal voltage on supply terminal U L24 V DCNominal current drawn from supply I LmA ≤ 50terminalNominal current drawn from module I MBmA ≤ 39 ≤ 40 ≤ 43busPower loss W normally 1Output voltage V DC - -10/0...+10Output current mA 0/4...20 -Load resistanceResistive load O < 450 > 1000Inductive load H < 0.001 -Capacitive load μF - > 1Short-circuit current mA - ≤ 40Transmission frequency Hz ≤ 200 ≤ 200 ≤ 100Offset error % ≤ 0.1Linearity % 0.02 - 0.1Basic error limit at 23 °C % < 0.2Repetition accurancy (deviation) % 0.05 - 0.5Output ripple % 0.02 - 0.02Temperature coefficient300 ppm/°C of full scalevalue150 ppm/°C of full scalevalue300 ppm/°C of full scalevalueRecovery timeResistive load ms 0.1 2 0.1Inductive load ms 0.5 2 0.5Capacitive load ms 0.5RFI suppression - Common mode > 90 dBDifferential mode > 70 dBCross talk between channels> -50 dBMeasured value representation16 Bit signed integer12 Bit full range flush-left16 Bit signed integer12 Bit signed integer flushleft12 Bit full range flush-leftNumber of parameter bytes 3 3 (per channel)Base moduleswithout C connection2- / 3-wireXN-S3x-SBBArticle no. 85 50 225179 85 50 230871 85 50 225180I/Oassistant MXpro – IEC 61131-3 XN-PLC-CANopen48www.microinnovation.com


XI/ONRemote I/O SystemTechnology ModulesXN-1CNT-24VDCCounter moduleChannels No. 1Nominal voltage on supply terminal U L24 V DCNominal current drawn from supply I LmA ≤ 50terminalNominal current drawn from module I MBmA ≤ 40busPower loss W < 1.3Power supply of encoders Output voltage L+ (-0.8 V)Output current ≤ 0.5 A, short-circuit proofDigital inputsInput voltageInput voltage nominal value V DC 24Low signal U L-30 V DC...5 V DCHigh signal U H11 V DC...30 V DCInput currentLow signal I L-8 mA...1.5 mAHigh signal I H2 mA...10 mAMinimum pulse width μs Filter on: > 25 ms (20 kHz), Filter off: < 2.5 ms (200 kHz)Digital OutputsOutput voltageOutput voltage nominal value V DC 24Low signal U L≤ 3 V DCHigh signal ≥ L+ (-1 V)Output currentHigh signal (permissible range) I HA 5 mA...2 AHigh signal (nominal value) I H≤ 0.5 A (55° C)Switching frequencyWith resistive load Hz 100With inductive load Hz 2with lamp load Hz ≤ 10Lamp load R LLW ≤ 10Output delay100 μs (resistive load)Short-circuit proofyesResponse threshold V 2.6...4 AInductive quenching L+ (-50...-60 V)Measuring rangesFrequency0.1 Hz...200 kHzSpeed1 rpm...25000 rpmPeriod duration5 ms...120 sCounter modesSignal evaluation A, BPulse and direction, rotary encoder single/double/quadrupleModeEndless, once only or periodic countHysteresis mm 0...255Pulse durations 0...255SynchronisationOnce only / periodicCount limitsUpper count limit: 0...7FFF FFFFLower count limit: 8000 0000...FFFF FFFFMeasuring modesSignal evaluation A, BPulse and direction, rotary encoder singleTemperature coefficient≤ 100 ppm/°C of full scale valueNumber of diagnostics bits 1Number of parameter bits 15Base modulewithout C connection, for transmittersupply4-wireXN-S4x-SBBSArticle no. 85 50 22518349


XI/ONRemote I/O SystemTechnology Modules XN-1RS232 XN-1RS485/422 XN-1SSIType RS 232 RS 484 / RS 422 SSINominal voltage on supply terminal U L24 V DCNominal current drawn from supplyterminalNominal current drawn from modulebusI LmA ≤ 25I MBmA ≤ 140 ≤ 90 ≤ 50Power loss W normally 1Transmission channels RxD, TxD, RTS, CTS RxD, TxD CL, DData bufferReceive Byte 128 -Transmit Byte 64 -Connection typeRS 232 full-duplex -RS 485 - 2-wire half-duplex -RS 422 - 2-wire half-duplex or 4-wirefull-duplexBit transmission ratemax. 115200 Bit/s (adjustable), default setting:9600 Bit/s, 7 data bits, odd parity and 2 stop bitsInsulation voltageBetween interface and module bus V rms500/ system voltageBetween interface and field voltage V rms500Common mode range V DC -7...12 -Cable impedance O - 1204-wire full-duplex (clockoutput/signal input)max. 1 MHz (adjustable),default setting: 500 kBit/sBus termination - 120 Ω (external) internalCable length RS 232 m max. 15 max. 1000 max. 30Number of diagnostics bits 1Number of parameter bits 4Base moduleswithout C connection4-wireXN-S4x-SBBSArticle no. 85 50 270321 85 50 270322 85 50 270323XI/ON technology modules:Interfaces and countersThe serial interface modules of the XI/ON range enable them to transfer serialdata streams via the XI/ON system. This enables the connection of differentdevices such as printers, scanners or barcode readers with a serial RS232, RS485or RS422 interface.The XN-1SSI module allows the connection of encoders with an SSI interface,a supply voltage of 24 V DC (500 mA), a word length of up to 32 bits and atransmission rate of max. 1 MHz.The XN-1CNT counter module detects normalized signals up to 200 kHz.50www.microinnovation.com


XI/ONRemote I/O SystemPower Supply Modules XN-BR-24VDC-D XN-PF-24VDC-D XN-PF-120/230VAC-DOperating voltage V DC 24 120 / 230 ACSystem supply U SYSV DC 24/5 -Permissible range 24 V DC U SYSV DC 18...30 -Permissible range 5 V DC U SYSV DC 4.7...5.3 -Field voltage U L24 V DCPermissible range - nach EN 61131-2Permissible range V DC 18...30 -Nominal current drawn from modulebusI MBmA - ≤ 28 ≤ 25Insulation test voltage U iV AC - 1780Ripple % < 5 (to EN 61131-2)Maxmium operating current I EIA 10Maximum system supply current I MBA 1.5 -Number of diagnostics bits 4Base modules without gateway supplywithout C connection - 2-/3-wireXN-P3x-SBBwith C connection4-wireXN-P4x-SBBC-B4-wireXN-P4x-SBBCArticle no. 85 50 225187 85 50 225186 85 50 225188Safety through codingThe pluggable design of the modulesenable them to be exchanged quicklyand without tools, even under liveconditions (hot swappable).The mechanical coding preventsmodules from being pluggedincorrectly.11 2112 2213 2314 24The base modules of the XI/ONstandard systems are available with 2, 3or 4-wire circuits and tension clamp orscrew terminals. An additional terminalstrip is unnecessary.51


WINblocRemote I/O SystemBridgesDigital I/O modules forCANopenAnalog I/O modules forCANopenThe bridge connects the expandable I/Omodules with Profibus-DP or CANopen, inwhich each I/O module represents a passivenetwork station on the fieldbus.The bus address setting is carried out withrotary coding switches on the I/O modules.■ A maximum of 10 I/O modules can beconnected per bridge■ Bus connection either via SUB-D ortension clamp terminals■ Fieldbus electrically isolated■ Operating voltage: 24 V DCDP BridgeTransmission speed: up to 1.5 Mbit/sDP Bridge/12 MBaudTransmission speed: up to 12 Mbit/sCAN BridgeTransmission speed: up to 1 Mbit/sInput modules 8/16/32-channelCAN-8-(16)DI/PCAN-16-(32)DI/P-2x8 (2x16)Output modules 4/8/16/32-channelEither 0.5 A or 2 AShort-circuit proof design -PKWith short-circuit monitoring LEDCAN-4DO/2.0A-PKCAN-8-(16)DO/0.5A-PKCAN-16-(32)DO/0.5A-P-2x8 (2x16)Combi modules 8/32-channelOptimum combination of input/output modulesEither 0.5 A or 2 A outputsShort-circuit proof design -PKWith short-circuit monitoring LEDCAN-4DI/4DO/0.5A-PKCAN-24DI/8DO/0.5A-PKRelay modules 8/16-channelMake contactCAN-8(16)DO-R-NOInput modules 4-channelInput ranges:10/0..+10 V, 0/4..20 mAResolution 16-bitReverse polarity protectionCAN-4AI/UIAnalog input PT100Resolution 0.1 K, 0.1 WCAN-4AI/PT100Analog inputThermo K, J, R, S, T, N, E, BResolution 1KCAN-4AI/ThermoOutput modules 4-channeloutput range:10/0..+10 V, 0/4..20 mAReverse polarity protectionResolution 16-bitCAN-4AO/UICombi modules 4-channelInput/output ranges:10/0..+10 V, 0/4..20 mAReverse polarity protectionCAN-3AI/1AO/UIWide selection of I/O functionsThe basic structure of the WINbloc system consists of a bridge, an electronic anda base module. The wide selection of I/O modules means that any possiblecombination can be implemented. Simply fit up to 10 I/O modules in a row andcreate the station exactly to the requirements of the application. It couldn‘t besimpler.Fast and economical wiringDifferent base modules with either 2, 3 or 4-wire connection are available for theconnection. Modularity on the entire line! The I/O points can be connected withtension clamp terminals allowing easier access.52www.microinnovation.com


WINblocRemote I/O SystemDigital I/O modules forProfibus-DPAnalog I/O modules andcounter for Profibus-DPWINbloc Eco forProfibus-DPInput modules 8/16/32-channelEither 24 V DC, 120 V AC or 230 V AC eitherpositive/negative switchingDP-8-(16)DI/P, DP-16-(32)DI/P-2x8 (2x16)DP-8-DI/N, DP-8-DI/115VAC (230VAC)Output modules 4/8/16/32-channelEither 0.5 A or 2 AShort-circuit proof design -PKWith short-circuit monitoring LEDDP-4DO/2.0A-PKDP-8-(16)DO/0.5A-PKDP-16-(32)DO/0.5A-P-2x8 (2x16)Combi modules 8/12/16/32-channelOptimum combination of input/output modulesEither 0.5 A or 2 A outputsShort-circuit proof design -PKWith short-circuit monitoring LEDDP-4DI/4DO/0.5A-PKDP-8DI/4DO/0.5A-PKDP-8DI/4DO/2.0A-PKDP-8DI/8DO/0.5A-PKDP-24DI/8DO/0.5A-PKRelay modules 8/16-channelEither make contact or potential-freechangeover contactDP-8(16)DO-R-NO, DP-8DO-R-COInput modules 4-channelInput ranges: 10/0..+10 V, 0/4..20 mAResolution 16-bit, reverse polarity protectionDP-4AI/UIAnalog input PT100Resolution 0.5 K, 0.1 W/0.25 K, 0.025 WDP-4AI/PT100Analog inputThermo K, J, R, S, T, N, E, BResolution 1 K, 0.25 KDP-4AI/ThermoOutput modules 4-channelOutput ranges: 10/0..+10 V, 0/4..20 mAReverse polarity protection, resolution 12-bitDP-4AO/UICombi modules 4-channelInput/output ranges:10/0..+10 V, 0/4..20 mAReverse polarity protectionDP-3AI/1AO/UICounter module 1-channel, 25kHzForwards/backward positioningCounter range 0..65535Limit preset via Profibus-DPDP-1CNT/24VDCWINbloc EcoThe economical and compact alternativefor connecting to Profibus-DP. The systemconsists only of a base and electronicmodule. A bridge is not required. Thefieldbus connection is implementedby direct wiring on the base module.Each WINbloc Eco module is a passivestation on the Profibus-DP network.In addition to the extensive diagnostics LEDs, the signals are also indicateddirectly and clearly at the terminals.Digital input modulesPositive switchingDP-16DI/P-ECODP-32DI/P-ECODigital output modulesPositive switchingShort-circuit proofDP-16DO/0.5A-PK-ECODP-32DO/0.5A-PK-ECOCombi modulesPositive switchingShort-circuit proofDP-16DI-P/16DO/0,5A-PK-ECOModular plug adapter –Reliable connectionThe electronics of the baseelements are contacted reliably byusing the sliding module bus link.A clip is used to ensure reliablemechanical connection.The electronic unit is then simplyplugged onto the base modulesand locked – that‘s it!53


SOFTWARE54www.microinnovation.com


GalileoInteractive Visualization ToolGalileo is an easy to learn and yet powerful and extensive project design environmentthat can be used ideally in all system and machine building applications close to themachine and process.Galileo is designed for use in all sectors and offers comprehensive project design for allgraphical operating devices from the Micro Innovation HMI product range as well as forstand-alone PC solutions. Galileo provides the project designer with a full range of functionswithout any graduated restrictions on tags or screens, and takes into account theperformance level of the panel used.56www.microinnovation.com


GalileoInteractive Visualization ToolReliable and simpleconnection to thecontrol level andoffice world.Comprehensiveproject designof all graphicalpanels up toand with thePC controlstation.GALILEO Highlights■ Fast project design with project simulation on thedesign PC■ Easy to learn and intuitive graphical user interface withproject overview window■ Different surface styles■ Drag & drop positioning of objects WYSIWYG(what you see is what you get)■ Simple parameter definition of objects■ Tabular object properties; easy and fast allocation ofattributes – copy & paste■ Panel meter objectSome of over 100 protocols to all standard PLCsUp to 8communicationoptions at thesame time, withdata bridge.A. BRADLEY DF1 / EtherNet/IPBECKHOFF TwinCAT ADSEIBEIB-ETS2MITSUBISHI A SeriesMOELLER easy / SucomA / Suconet K / CANopen / CoDeSysOMRON C H K SeriesSAIAS-Bus / MPISIEMENS PPI / MPI / DP Slave / Industrial EthernetTELEMECH. Unitelway newVarious OPC / Modbus RTU / Modbus TCP/IP /CoDeSys (SymArti) / CANopen (SDO/PDO) / 3964R■ Enhanced password handling with complex passwortand aging■ Extensiv recipe handling■ Alarm handling with time stamp, history anddiagnostics support with picture display■ User-friendly multiple definitions of texts and picturesto variables■ Many graphical objects such as bargraph, slide adjuster,graph plot, camera■ Object parameter list, any number of data objects onone screen■ Dynamic measuring unit change(e .g. °C ↔ °F, inch ↔ mm)■ Many specific objects and functions■ Direct printing on the panel (reports, forms)■ Brilliant picture display with up to 65536 colors■ Import of 15 different picture formats■ Simple import of PLC variables■ Online language change■ Unicode support (also Asian character sets)■ Text import/export in XML format, e. g. Excel■ Always full functionality available, no graduatedperformance■ Dynamic objects57


GalileoFast, Simple Project DesignFast project designThe required project data and informationis shown in clearly visible groupsin the project overview for simpleselection. Other useful functions areavailable in every individual group viathe context menu.A number of ready-to-useobjects for fast projectdesignSimple configuration of objectsDouble-clicking the object concernedwill activate the object configuration:Tag selection, object style, BMP/Text/colors, object-related settings, viewand operability.Online language change, Text export/import with Unicode supportAn export and import interface allows youto extract texts in XML format from theproject and translate them with externaltools (e.g. Excel).Unicode support means that Asian picturecharacters can also be implemented.Different languages can also be selected onthe panel.58www.microinnovation.com


GalileoFast, Simple Project DesignProject ready in a few steps3Create screens.Full screens, sub screens, dialog screens anduser-defined entry screens can be designed.Several ready-to-use standard screens for efficientproject design are also available.1Open the project and select the panel type.The project will automatically allow all the featuresof the selected panel.4Create variables or import from MXpro(CoDeSys).A specific entry dialog is provided for tagdefinition according to the communicationprotocol selected. Data from MXpro or otherCoDeSys-based PLCs can be imported easilyand synchronized when the PLC project ischanged.6Simulation of the project on the designPC.Your project can be compiled and simulateddirectly on the design PC at any time. Detailederror messages and warnings notify you ofany inconsistencies in the project. The simulationtool enables your project to be testedeasily and developed efficiently.2Select communication.Up to 8 communication protocols can be operatedsimultaneously from a selection of over 100.Data can thus be transferred via the panel fromPLC to PLC.5Position the object on screen.Drag & drop functionality allows all visualizationobjects to be positioned on the screensand their wide range of properties to thenbe adapted to the application at hand.7Download to the panel.Once the compilation has been successfullycompleted, the project can be transferredduring operation by clicking “Online” on thepanel.59


MXproPLC Programming Compliant With International StandardsAll xSystem controllers of Micro Innovation are programmed with MXpro. MXpro isbased on standard CoDeSys software from 3S. Fully developed technical features, simplehandling and a widespread use of this software in automation components for differentmanufacturers guarantee successful programming with this software.User-friendly PLC configurationProgramming languagesInstruction list (IL) and structured text (ST)Function block diagram (FBD)Freely definable function block chart/continuous functionchart (CFC)Ladder diagram (LD)Sequential function chart (SFC)Engineering featureAutomatic variable declarationAutomatic formatting and coloring of code/declarationtextThe right programming languagefor every task(IL, ST, FBD, CFC, LD, SFC)Extensive debugging andcommissioning tools save timeand moneyA number of features simplify application creation andsupport one aim: cost savings by reducing engineeringtimes.Here is a selection of other features: Global search andreplace, generation and use of libraries, context-sensitivehelp, output of a cross-reference list, checking of unusedtags, etc.Debugging and commissioningMXpro offers you a number of important functions fordebugging, testing and commissioning your PLCapplications quickly and efficiently.All these features are available as soon as you log onto thePLC (online mode)SimulationYou can also test your application program when the PLC isnot connected.This is possible thanks to the integrated online simulation.You don‘t need to forgo the regular operator interfaceeither, and handling is not any different to online mode withthe PLC connected.60www.microinnovation.com


MXproPLC Programming Compliant With International StandardsMultitaskingUp to 16 time and/or event driven tasksVisualizationIntegrated tool for diagnostics and commissioning supportConfigurationConfigurator for local I/Os as well as CANopen andProfibus-DP stationsMultitaskingThe structuring of the application into several independentruntime programs (multitasking) optimizes the resources ofyour PLC and simplifies the implementation of time-criticaltasks. Give priority to high-speed processes and provide slowerprocesses with only as much processing time as required.CommunicationRS232, Ethernet, in distributed networks viaCANopen, OPC server, UDP, TCP/IP, FTP client/server, Modbus Master/Slave, email, SMSPassword protection8 levelsLanguagesD, GBLibrariesIEC, memory card access,closed-loop control, motion control, etc.Special featuresNetwork variables for cross traffic via CAN and EthernetFieldbus configurator includedThe hardware configurator shows all the local I/Os and theremote periphery (Profibus or CANopen) on one user interface.You can configure and parameterize the inputs and outputsdirectly, and assign them with a symbolic name. This preventsthe occurrence of any assignment errors between the peripheraldevices and the PLC program. You can also test variables inonline mode.I/OassistantInstantly online, instantly viewed, instantly testedThe I/Oassistant integrated in MXpro provides you with aspecifically designed tool for configuring XI/ON from MXpro.Without leaving MXpro, all the functions of the I/Oassistantare available for interactively planning and implementing yourremote XI/ON station.For this you select gateways, electronic and base modules aswell as the corresponding accessories.The tool automatically checks that the structure is correct.The individual stations are then configured offline or online.Once everything is set to your satisfaction, you can put thesystem into operation.61


MXproApplication LibrariesApplikationsbibliothekenerweitern die Funktion der SteuerungMicro Innovation provides ready-to-use libraries for programming the controllers withMXpro for several applications.The libraries can be incorporated simply via the MXpro Library Manager.The additional function blocks of the libraries are then available like all other standardfunction blocks. The function block interfaces are kept as simple as possible and are normallyeasy to understand without requiring any extensive study in manuals.The user is therefore provided with ready-to-use solutions for automation tasks in manysituations involving closed-loop and motion control.62www.microinnovation.com


MXproApplication LibrariesClosed-loop controltoolboxThe closed-loop control toolbox containsaround 120 function blocks.This firstly enables the implementedclosed-loop control know-how to beutilized with the standard functionblocks and secondly allows functionblocks to be combined and cascadedin order to create special applicationsolutions.PID controller: The right controller canbe selected for every control problem.The split range PID controller thusprovides solutions for typical heating /cooling temperature controllers.The autotuning controller is used for theautomatic setting of the parameters atthe start of the control phase.Three step controller:In addition to standard PID three stepcontrollers, other robust and easy to setvariants are available that are suitablefor any valve opening time.The scan times of differential andintegral components are optimizedautomatically.Pulse width modulation (PWM):If the control system does not have ananalog actuator, pulse width modulationoutputs are connected behind thePID or fuzzy controllers.Conventional PWM algorithms are availableand the noise-shape process witha highly dynamic switching frequency.Fuzzy control: The fuzzy functionblocks enable even inexperienced usersto integrate fuzzy systems/controllers ina control concept. Even the gain factoror setpoint of a PID controller can beprogrammed effortlessly with fuzzylogic.Signal processing andsimulations:Ramp delay function blocks and PT1filters can be used to improve signalquality. First to tenth order PTn controlsystems can be simulated with thetoolbox function blocks without anadditional software package.Motion control toolboxThe motion control toolbox containsapproximately 40 function blocks thatcan be individually integrated andadapted to the automation solution inquestion.PositioningThe toolbox contains basic positioningfunction blocks for elementary tasksand also more powerful function blockswith the following features: positioning (e.g. interpolation) turning) with optimized paths overthe zero point limitation positioning range monitoring positioning coverage of hydraulic axesPossible applications include handlingtasks in the automobile supplierindustry (manufacture of cup springsand spiral springs), winding of spiralsprings, cable winding machines, pipebending, positioning and synchronizationof stages or curtains in theaters.Electronic gearsAn electronic gear system can beimplemented with the synchronizationfunction blocks.Different speeds can be synchronizedwith any transmission ratio.Angle synchronization with onlineconfigurable offset between masterand slave axes is also possible.Three master axis variants are provided.The internal master is controlled in thesame program. The external master isused by an external device to controlthe master. An incremental encoderrecords the motion of the master axis.With the virtual master, the slave axesfollow a simulated axis.Applications include: Press synchronizationcontrol with virtual master; angleand speed synchronization of belts;drawing of weaving materials with 5slave axes and increasing transmissionratio per axis.Flying sawThe “flying saw” function is a combinationpositioning and electronic gears.Positioning operations are carried outrelative to the synchronized motion.63


MXproCommunication LibrariesCommunication functions are increasingly becoming a central element in automationsolutions. In addition to the conventional remote connections for peripheral devices viafieldbus systems such as CANopen or Profibus, data communication between PLCs orhigher-level systems are of major importance. OPC, FTP, TCP/IP, email, web are just someof the technologies here that can be used for data communication or for transferringfiles.FTP-ClientFTP-ServerEthernet TCP/ IPEthernetTCP/UDPModbus IPEthernetTCP/IPMobilfunknetzModemFTP-ServerFTP-ClientOPC-ClientOPC-ServerXV200FTP server: Updatingrecipe dataMicro Innovation controlleruses a standard filesystem for internal programstorage. This also appliesto the pluggable externalmemory cards or a memorystick connected via the USBinterface. Recipe data canbe created really easily as a“normal“ file, transferredto the PLC and read fromthere. Recipe data can nowthus be updated easily viaany PC.FTP client: Sending dataarchives automaticallyThe FTP client functionblocks enable files that werecreated by the PLC to alsobe stored on any drives thatcan be accessed via thenetwork. If, for example, thetarget drive is not accessibledue to problems on the network,an alternative drivecan be accessed.Daily or weekly logs canthus be stored locally andarchived at any time. Witha few function block calls,files can be saved from thePLC onto a network drive.UDP and TCP/IPUDP and TCP/IP areprotocols used on very manyoperating system platforms,which enable a simple andstandard data exchangebetween the PLC andexternal systems.This can be other controllersor even PC-based applications.Modbus / TCPModbus is a communicationprotocol that is widelyused with different communicationmedia. Modbus canbe implemented as a serialconnection (RS232/485)or as a Modbus IP Ethernetversion.Ready-to-use libraries forthe masters and also theslave function are alsoavailable.OPC serverVirtually all SCADA, visualizationand control systemssupport the OPC client/server interface.The OPC server is used bythe controllers to presentthe process data to the OPCclients.The OPC server supportsdata access via the serialinterface and via theEthernet, and each OPCserver is able to processrequests from severalclients. If data is to be usedseveral times, for exampleby a visualization systemor a database, differentsoftware packages canaccess the data of the OPCserver without the need forany manufacturer specificconventions or additionalimplementations.Further information and downloads arecan be obtained at:http://www.microinnovation.comSMS messaging or emailSystem states or alarmmessages can be sent simplyby SMS or email – whetherfor logging or for direct SMScommunication with the FAXservice technician.The ready-made usermodules provide you withall the options you need tobe always notified in timeabout the operating state ofthe machine or plant.64www.microinnovation.com


I/OassistantConfiguration Software for XI/ON and WINbloc I/O SystemInstantly online, instantly viewed, instantly tested!The I/Oassistant provides you with a universal tool that supports you interactivelythroughout the planning and implementation stage of your XI/ON system. First of all,you need to create and structure a project on screen. To do this, you select gateways,electronics/base modules and the appropriate accessories. Then you configure the individualstations either offline or online. Once everything is set to your satisfaction, you canput the complete system into operation.Commissioning without a fieldbus masterThe I/Oassistant checks the station, reads in process data,outputs values and visualizes the diagnostics data of thechannels. In this way you can commission your station withouta higher-level controller and ensure that sections of the systemare operating correctly.You set the outputs and modify values directly from the PC. Byforcing the values you can instantly view the behavior of yourapplication. You can thus check the field wiring, for example,without having a fully installed control system.Integration in MXproThe I/Oassistant integrated MXpro is the special configurationtool for XI/ON and can also be accessed from within MXpro.You can therefore make full use of all I/Oassistant functions forinteractive planning and implementation of your remote XI/ONstation without having to exit MXpro.Design plan and parts list generationOnce the planning has been completed, the software cangenerate a detailed project documentation that includes overviewpicture and parts lists.EPLAN supportEPLAN macros are available for the XI/ON modular I/O system.This saves the time required for configuring and helps toprevent configuration errors.65


EPAMVisualization Tool under Microsoft OfficeEPAM is designed as an open visualization system for OEM machine builders and can beextended at any time with the customer‘s own functions using Visual Basic macros.Simple and efficient projectdesign with EXCELImport of variablesfrom MXproEasy positioning... and it‘s readyProject design with MS ExcelThe visualization project is designed in Microsoft Excel. OnceEPAM is installed and an add-in is installed in Microsoft-Excel,all the necessary commands and objects are available fordesigning a visualization system. Button, switch, alphanumericvariable, bargraph, message element, bitmaps etc.The PLC variables can be imported simply from MXpro. Theproject is designed in a tabular description of the visualizationsystem. The tables are then later interpreted on the targetsystem by the EPAM runtime.An interpreter is also provided within Excel.This enables functions and the screens to be tested beforehandon the design PC. This test also enables the visualizationof process values from the PLC. All the features of Excel areavailable during the project design phase.Already existing screens or objects can be reused simply withCopy & Paste.A program expansion with custom Visual Basic macros enablesthe system to be linked to external data sources.66www.microinnovation.com


EPAMVisualization Tool under Microsoft OfficeWEB-EPAM enables both new and existing EPAMapplications to be turned into remote HMI systems viathe Intranet/Internet.EPAM applicationWEB-EPAMEach visualization system created with EPAM is web-enabledautomatically. A Java applet is simply loaded on the targetsystem via the integrated web server and generates a 1:1 imageof the visualization in any standard Java-compatible browser,enabling the system to be operated remotely with any standardPC without the need to install additional software.Identification is implemented with user passwords so that onlyauthorized persons are allowed access.Intra-/InternetJava-enabled standard browserPicture in picture display with EPAM remote controlEPAM‘s remote control object enables the screen pages of othertouch screens to be displayed.The operating states of individual system sections can thus bediagnosed and controlled remotely.A 1:1 copy of the actual image of a XV400 with a 5.7“ display isshown on the visualization page of a XV400 with a 10.4“ display.All touch functions can be carried out locally or remotely via thescreen shown in the remote XV400. All this is possible at no extracost and without any additional engineering requirements orsoftware packages.67


ToolsS7-PG-RouterThis tool enables the programming of S7 programmable controllersconnected to the Micro Innovation panel via its Ethernet interface.XV200 and XVS400 devices with onboard Profibus and Ethernetinterface support the S7 PG Routing function.Step7Programming deviceEthernetPanel withS7-PG-RouterCAN-MonitorThe CAN Monitor tool enables the monitoring and tracing of CANtelegrams with a related time stamp, COB-ID and data directly onthe Micro Innovation panel. Error frames are not detected. XV100,XV200 and XV400 devices with onboard CAN interface support theCAN monitor function.CE-TelediagThis tool enables user-friendly teleservice via a modem connectionwith a dialup assistant and device callback. XV100, XV200, XVS400and XV400 devices with onboard System Port (RS232) interface supportthe CE Telediag function.SCADAControlpanelDXS-ServerStandard, secure and event-driven data communicationPLC specific datacommunicationThe universal Micro Innovation panel allows a wide range of PLCsystems to be combined homogeneously and integrated in the controllevel via the DXS service (Data Exchange Service). Communicationwith the higher-level network is implemented via a rugged, eventdrivenand transaction-oriented protocol and via Ethernet.This open networking facility enables data from all data sources to beprocessed uniformly and efficiently, both in control desks, secure dataservers and in ERP systems. Process evaluations can also be created inExcel.68www.microinnovation.com


SoftwareOverviewVisualization software Type Article No.GALILEO SW-GALILEO 91 25 000021GALILEO OPEN LIC-GALILEO-OPEN-PC 91 30 000020EPAM SW-EPAM 91 25 000050PLC programming software Type Article No.MXpro SW-MXPRO 91 24 000007Tools Type Article No.S7-PG-Router SW-S7-PG-ROUTER 91 26 000001CE-Telediag SW-CE-TELEDIAG 91 26 000015CAN-Monitor SW-CAN-MONITOR 91 26 000005DXS-Server SW-DXS-SERVER 91 26 00001069


Services With Special Customer ProximityConsulting Field Service TrainingPartnerSupport70www.microinnovation.com


Consulting / SupportOur commercial hotline is available for any inquiries concerningorders, shipments and prices.+49 (0) 228 602 2020Our support specialists are available for technical questionsabout our products and their programming.+49 (0) 228 602 2002Field ServiceThe Field Service offers fast and competent support inthe event of emergencies such as machine or systemoutages. The Field Service offers tailor-made service andmaintenance contracts. For this Micro Innovation usesthe Field Service of Moeller GmbH which has been triedand tested for many years.+49 (0) 228 602 3666(available 24h / 365 days)Information atinfo@microinnovation.comMicro Innovation GmbHNideggerstrasse 6-1053115 BonnGermanyMicro Innovation AGSpinnereistrasse 8-149008 St. GallenSwitzerlandWe would like you to visit our companyPlease send us information material:Automation Product OverviewTrainingMicro Innovation can offer training courses and workshopsspecially tailored to your requirements.Solution ProviderMicro Innovation works closely with competent partnersthat support or implement your software projects asrequired.Company:Name:First name:Department/Function:Street:Zip code/Town:Country:Telephone:E-mail:Please add my name to the distribution list foryour electronic newsletter.71


Eaton’s electrical business is a global leaderin electrical control, power distribution,uninterruptible power supply and industrialautomation products and services.Eaton’s global electrical brands, includingCutler-Hammer®, MGE Office ProtectionSystems, Powerware®, Holec®, MEM®,Santak, Moeller and Micro Innovation,provide customer-driven PowerChainManagement® solutions to serve the powersystem needs of the industrial, institutional,government, utility, commercial, residential,IT, mission critical and OEM marketsworldwide.www.eaton.comFind international sales offices online:www.microinnovation.cominfo@microinnovation.comHoldingMicro Innovation Holding AGSpinnereistrasse 8-149008 St. GallenSwitzerlandTel.: +41 (0) 71 243 24 00Fax: +41 (0) 71 243 24 90Product CompanyMicro Innovation AGSpinnereistrasse 8-149008 St. GallenSwitzerlandTel.: +41 (0) 71 243 24 24Fax: +41 (0) 71 243 24 90Sales CompanyMicro Innovation GmbHNideggerstrasse 6-1053115 BonnGermanyTel.: +49 (0) 228 602 2020Fax: +49 (0) 228 602 1713Service/Repair CenterMicro Innovation GmbHCarl-Benz-Strasse 1978224 SingenGermanyTel: +49 (0) 7731 7896 110Fax: +49 (0) 7731 7896 101