<strong>Biochip</strong> <strong>Array</strong> <strong>Technology</strong><strong>The</strong> <strong>Technology</strong> <strong>and</strong> <strong>Applications</strong><strong>of</strong> <strong>Protein</strong> <strong>Biochip</strong> <strong>Array</strong><strong>Technology</strong>Katie Walker<strong>Biochip</strong> <strong>Array</strong> Product SpecialistPanels <strong>of</strong> tests,allowing for thesimultaneous multianalytedetection <strong>of</strong>a wide range <strong>of</strong>analytes, from asingle undividedsample•81mm 2 Solid StateDevice•Assays contained indiscrete reaction sites•Single patient sampleper biochip•Multiple assaysperformedsimultaneously


Development <strong>of</strong> <strong>Biochip</strong> <strong>Array</strong>• 1992 – 2003• Over 185 Scientists involved• $140,000,000.00 Investment• 45 new patents• Three main stages in <strong>Biochip</strong> development– Synthetic Chemistry– Nano Dispense– Detection technology<strong>The</strong> <strong>Biochip</strong>• <strong>The</strong> crux <strong>of</strong> the technology is the <strong>Biochip</strong> itself• Coated in a proprietary silanation process– Activation <strong>of</strong> the <strong>Biochip</strong> surface• Ensures uniformity <strong>and</strong> reproducibility– Modification <strong>of</strong> surface chemistry• Controlled anti-body binding in optimal orientation


<strong>Biochip</strong> Surface ChemistryNon -activated SurfaceActivated Surface


<strong>Biochip</strong> ManufacturingNano Dispense <strong>of</strong> Antibody solution• All manufactured by R<strong>and</strong>ox at our HQ in theU.K.• 20 million chip per year capability• Fully automated clean-room facilityQuality ControlQuality Control• Quality control is at the heart <strong>of</strong> all that R<strong>and</strong>ox does.• Quality is ensured at every level <strong>of</strong> product– Pre process• Quality components• R<strong>and</strong>ox Antibodies– In process• Manufactured to ISO 13485• Ensures reproducibility– Post Process• Internal QC to ensure Functionality, integrity <strong>and</strong>stability


Immunoassay FormatsCompetitive ImmunoassayDETECTION• Tried <strong>and</strong> trusted EIA• S<strong>and</strong>wich immunoassay– Cytokine <strong>and</strong> Growth Factor <strong>Array</strong>• Competitive immunoassay– Drugs <strong>of</strong> Abuse <strong>Array</strong>CONJUGATEEY YANALYTEANTIBODY• Horse Radish Peroxidase LabelSUBSTRATESignal Analysis• Chemiluminescence• L.O.D. compared– Fluorescence (ELISA) 2,000,000 zeptomoles– Radio Immunoassay 1,000,000 zeptomoles– Chemiluminescence 25,000 zeptomoles» Tietz ‘Clinical Chemistry’• Imaged with super cooled CCD camera• Quantified by custom s<strong>of</strong>tware


Available <strong>Array</strong>sDrugs <strong>of</strong> Abuse <strong>Array</strong> 1• Drugs <strong>of</strong> Abuse <strong>Array</strong> 1• Cytokine <strong>and</strong> GrowthFactor <strong>Array</strong> 1• Free Thyroid <strong>Array</strong>• Total Thyroid <strong>Array</strong>• Fertility <strong>Array</strong>• Tumour Monitoring<strong>Array</strong>• Tumour PSA <strong>Array</strong>• Adhesion Molecule<strong>Array</strong>• Cardiac <strong>Array</strong>• Growth Promoter <strong>Array</strong>• Anti-Microbial <strong>Array</strong> 1• Cardiovascular DNA<strong>Array</strong>• Colorectal Cancer DNA<strong>Array</strong>• Anti-Microbial <strong>Array</strong> 2*• Anti-Microbial <strong>Array</strong> 3*• SyntheticSteroids<strong>Array</strong>*• Drugs <strong>of</strong> Abuse <strong>Array</strong>2*• Amphetamine• Methamphetamine• Barbiturates• Benzodiazepine I• Benzodiazepine II• Cocaine Metabolite• Methadone• Opiates• Phencyclidine• Cannabinoids• Creatinine (urineapplication only)Drugs <strong>of</strong> Abuse <strong>Array</strong> IIDrugs <strong>of</strong> Abuse <strong>Array</strong>s• Buprenorphine• Fentanyl• Ketamine• LSD• MDMA• Hydromorphone• Methaqualone• Oxycodone I• Oxycodone II• Propoxyphene• Creatinine*• Specific matrix optimised kits for– Urine (FDA cleared)– Urine Semi-Quant– Whole Blood Quant– Oral Fluid Quant


Amphetamine ClassUrineBloodOral FluidUrineBarbituratesBloodOral FluidTargetd-Amphetamine /+ Methamphetamined-Amphetamine /+ Methamphetamined-Amphetamine /+ MethamphetamineTargetPhenobarbitalPhenobarbitalPhenobarbitalCut-<strong>of</strong>f1000 ng/mL /1000 ng/mL25 ng/mL /50 ng/mL50 ng/mL /50 ng/mLCut-<strong>of</strong>f200 ng/mL50 ng/mL5 ng/mLCross reactivity (urine)Amphetamine assayMethamphetamine assayCross reactivity (urine)Barbiturates assayd-Amphetamine+ MethamphetamineMDAMDMA100%


CannabinoidsMethadoneUrineBloodOral FluidUrineBloodOral FluidTarget11 nor − 9 THC-COOH11 nor − 9 THC-COOH− 9 THCTargetMethadoneMethadoneMethadoneCut-<strong>of</strong>f50 ng/mL10 ng/mL4 ng/mLCut-<strong>of</strong>f300 ng/mL25 ng/mL5 ng/mLCross reactivity (urine)Cannabinoids assay11 nor − 9 THC-COOH11 nor − 8 THC-COOH11 hydroxy − 9 THC11 hydroxy − 8 THCCannabinolCannabidiol100%49%3%


TargetCut-<strong>of</strong>fCocaine MetaboliteUrineBloodOral FluidBenzoylecgonine Benzoylecgonine Benzoylecgonine300 ng/mL50 ng/mL20 ng/mLCross reactivity (urine)Cocaine metabolite assayBenzoylecgonine100%Cocaine6.4%Cocaethylene4.1%Ecgonine


METHAMPHETAMINE AMPHETAMINE BENZODIAZEPINESGC-MSGC-MSGC-MS+ - + - + -EVIDENCE + 1 0 EVIDENCE + 0 1 EVIDENCE + 7 0- 0 32 - 0 30 - 0 23% AGREEMENT 100.0 % AGREEMENT 96.8 % AGREEMENT 100.0METHADONE OPIATES PHENCYCLIDINEGC-MSGC-MSGC-MS+ - + - + -EVIDENCE + 4 0 EVIDENCE + 3 0 EVIDENCE + 1 0- 0 29 - 0 29 - 0 32% AGREEMENT 100.0 % AGREEMENT 100.0 % AGREEMENT 100.0BENZOYLECGONINEOVERALLGC-MSGC-MS+ - + -EVIDENCE + 10 0 EVIDENCE + 26 1- 0 22 - 0 198% AGREEMENT 100.0 % AGREEMENT 99.6Urine Evaluation• FDA Trials• To assess the overall performance <strong>of</strong> drugs<strong>of</strong> abuse screening on the evidenceimmunoassay technology• To compare the evidence performance to analternate immunoassay system• To compare the evidence performance toresults obtained by GC/MSUrine EvaluationAmphetamines• More than 1300 clinical urine samplescovering the entire range <strong>of</strong> possible testresults for all ten drugs <strong>of</strong> abuse• Comparison carried out by independentclinical toxicology laboratory in Texas• 10% <strong>of</strong> samples fell within ±25% <strong>of</strong> theassay cut-<strong>of</strong>f concentrations10080604020096.8 96.782.1% AGREEMENT% DISAGREEMENT17.93.23.3evidence with CEDIA evidence with GC/MS CEDIA with GC/MS% Agreement Total number <strong>of</strong> samples Discrepant samplesevidence with CEDIA 96.8 1264 40evidence with GC/MS 96.7 305 10CEDIA with GC/MS 82.1 234 42


MethamphetamineCannabinoids10096.7 97.010097.993.98082.28081.86040% AGREEMENT% DISAGREEMENT6040% AGREEMENT% DISAGREEMENT2017.803.33.0evidence with CEDIA evidence with GC/MS CEDIA with GC/MS20018.26.12.1evidence with CEDIA evidence with GC/MS CEDIA with GC/MS% Agreement Total number <strong>of</strong> samples Discrepant samplesevidence with CEDIA 96.7 1249 40% Agreement Total number <strong>of</strong> samples Discrepant samplesevidence with GC/MS 97.0 305 9evidence with CEDIA 97.9 1335 28CEDIA with GC/MS 82.2 219 39evidence with GC/MS 93.9 231 14CEDIA with GC/MS 81.8 231 42OpiatesOverall Summary1008092.689.1% Agreement604060.040.0% AGREEMENT% DISAGREEMENTEvidence with CEDIA 96.9207.410.9Evidence with GC/MS 90.50evidence with CEDIA evidence with GC/MS CEDIA with GC/MSCEDIA with GC/MS 83.4% Agreement Total number <strong>of</strong> samples Discrepant samplesevidence with CEDIA 92.6 1334 99evidence with GC/MS 89.1 320 35Total number <strong>of</strong> tests 11,750CEDIA with GC/MS 60.0 320 128


User Defined Cut-<strong>of</strong>fselection.Analysers <strong>and</strong> S<strong>of</strong>twareFeatures• Semi-automated• Based on <strong>Biochip</strong> <strong>Array</strong> <strong>Technology</strong>– Multiple test sites per biochip• Fast Results– 54 biochips ie. 540 Tests in 1 hour• Small sample volumes– Urine – 3.5μl per test– Whole Blood - 6μl per test– Oral Fluid - 10μl per test


Features• Quality <strong>of</strong> results– All R<strong>and</strong>ox products are developed to ISO 13485,diagnostic st<strong>and</strong>ards– Full trace-ability through manufacture– Antibody Specificity– Self sufficient antibody supply– Specific Methamphetamine <strong>and</strong> LorazepamassaysFeatures• Cut-<strong>of</strong>f selection– Cut-<strong>of</strong>fs can be selected <strong>and</strong> reselected withoutrecalibration– Different cut-<strong>of</strong>fs can be selected for the sameanalyte during the same run, ie. Opiates sample A25ng/mL, sample B 10ng/mL.• Fully Quantitative Analysis– Identified as positive/negative– Concentration <strong>of</strong> compound also displayedFeatures• S<strong>of</strong>tware– Windows XP® based– Colour coding easy to follow– Multiple search formats– Easy export <strong>of</strong> results– Fully LIMS connectable– Extensive QC facilities• Levy Jennings <strong>and</strong> Multi-point rules.– Enhance trouble shooting


Features• Fully Automated– Walk away system• High throughput– 130 samples per hour x no.<strong>of</strong> tests per chip• Chain <strong>of</strong> custody Features– Sample access doors lock once sample is loaded• Password ProtectedFeatures• Retrospective Testing– Although only invoiced for tests reported, all assaysare carried out simultaneously– If certain assays are not reported they can be recalledat a later stage.


ReferencesMolloy RM, McConnell RI, Lamont JV, FitzGerald SP.Automation <strong>of</strong> biochip array technology for quality resultsClin Chem Lab Med; 43 (12):1303-1313FitzGerald SP, Lamont JV, McConnell RI, Benchikh EO;Development <strong>of</strong> a high throughput automated analyserusing biochip array technology; Clinical Chemistry; 51 (7)1165-1176www..com