11.07.2015 Views

Rainin Catalog - Mettler Toledo

Rainin Catalog - Mettler Toledo

Rainin Catalog - Mettler Toledo

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

RAININXLS PipettesThe performancechampions.The Best in Class... Again!Low Force – Extreme Accuracy and PrecisionPipet-Lite XLS is the latest in a long line of advancedergonomic pipettes from <strong>Rainin</strong>, and is one of the mostergonomic manual pipettes in the market. With acompletely redesigned body, the pipette fits your handlike a glove and its rugged construction will give yearsof accurate and precise performance. Extremely lowplunger and tip ejection forces help reduce or eliminatefatigue that could contribute to errors, affecting yourvaluable results.Ergonomic DesignLight weight, fits your hand.Low Plunger ForcesEven lighter springs, low-drag seals, andMagnetic Assist reduce plunger force.Lowest Tip Ejection ForceLTS LiteTouch System dramatically reduces tipejection force to only 0.6 kg.Silicone Shock AbsorberBuilt-in silicone shock absorber reduces impactand protects the thumb during tip ejection.Durable, rugged constructionThe extremely strong and lightweight PVDF(polivinylidene fluoride) handle with stainless steelpiston and tip ejector make Pipet-Lite XLS ruggedand reproducible in any lab situation. Pipet-Liteexhibits the fewest out-of-tolerance “as-found“failures among all pipettes serviced at <strong>Rainin</strong>.Built-in RFID TagAll Pipet-Lite XLS models feature a RFID (radiofrequency identification) tag which facilitatesservice calibration tracking and asset management.A first in a pipette!www.mt.com/rainin 8 | 9


RAININ<strong>Rainin</strong> PipettesPipet-Lite XLS The world’s best pipettes just got better<strong>Rainin</strong>’s new Pipet-Lite XLS family of pipettes brings precision,ergonomics and asset management to an entirely new level.With their sure-fit handles, lighter springs and <strong>Rainin</strong>’s patentedMagnetic Assist technology, these high-performance instrumentsare designed for ultimate comfort and ergonomic safety. Theyare also the world’s first pipette family to be equipped with RFIDtags for advanced calibration and asset management.Pipet-Lite XLS is the world’s first pipetteequipped with Radio Frequency IdentificationSmall sealPositive stopSingle ChannelLTS and TraditionalMultichannel8 and 12 channelAdjustable Spacer6 and 8 channelTotal hand comfortLighter spring, low-drag seals and<strong>Rainin</strong>’s patented Magnetic Assist technology have enabled us to create aplunger that is smooth and precise, yetrequires less force than ever.Less thumb stressOptional LTS system dramatically reducesthe repetitive stress of tip ejection.With LTS, the cylindrical shaft, smallseal area and positive stop in the tipcreate a firm, snug seal that requiresminimal force.Volume lockThe snag-proof design allows rapidvolume adjustment even when wearinggloves, preventing accidental volumedrift and delivering consistent results.Multi-channel consistency<strong>Rainin</strong>’s patented LTS LiteTouch System assures a leak freeseal on every channel, and with minimal force. With no nozzleo-rings, Pipet-Lite XLS’s design eliminates a weak point andpotential source of contamination.Ultimate flexibilityWith our Adjustable Spacer model, all it takes is a simpletwist of a dial to quickly move samples between differentplate and tube formats. Speeds your workflow.Watch the Pipet-Lite XLS demowww.mt.com/raininXLSwww.mt.com/rainin10 | 11


RAININ<strong>Rainin</strong> PipettesPipet-Lite XLS with RFIDLow forces, extreme accuracyTechnical DataThe new Pipet-Lite XLS, with proven accuracy andprecision, is one of the the most ergonomic manualpipettes on the market. Its comfortable handle, lightsprings and “Magnetic Assist” technology assuresmooth operation and significantly reduce risk ofrepetitive strain injury. Pipet-Lite XLS is the world’sfirst pipette equipped with RFID tags for advancedcalibration and asset management. Tip shaft optionsinclude low-force LTS for improved ergonomics, anduniversal fit.Ordering InformationLTS models MT Order No. Volume RangeL-2XLS 17011847 0.1–2 µlL-10XLS 17011780 0.5–10 µlL-20XLS 17011835 2–20 µlL-100XLS 17011781 10–100 µlL-200XLS 17011791 20–200 µlL-300XLS 17011848 20–300 µlSpecificationsVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)L-2XLS, SL-2XLS 0.2 0.002 12.0 0.024 6.0 0.0121 2.7 0.027 1.3 0.0132 1.5 0.030 0.7 0.014L-10XLS, SL-10XLS 1.0 0.02 2.5 0.025 1.2 0.0125.0 1.5 0.075 0.6 0.0310.0 1.0 0.1 0.4 0.04L-20XLS, SL-20XLS 2 0.02 7.5 0.15 2.0 0.04L-1000XLS 17011782 100–1000 µl10 1.5 0.15 0.5 0.05L-2000XLS 17011790 200–2000 µl20 1.0 0.2 0.3 0.06L-5000XLS 17011845 500–5000 µlL-10MLXLS 17011783 1000 µl– 10 mlL-20MLXLS 17011834 2000 µl– 20 mlL-STARTXLS 17011844 Starter Kits**Include 20, 200, 1000 µL models, tips, and accessoriesL-100XLS, SL-100XLS 10 0.2 3.5 0.35 1.0 0.150 0.8 0.4 0.24 0.12100 0.8 0.8 0.15 0.15L-200XLS, SL-200XLS 20 0.2 2.5 0.5 1.0 0.2100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3L-300XLS, SL-300XLS 20 0.5 2.5 0.75 1.0 0.3150 0.8 1.2 0.25 0.375Ergonomic championWhether it’s actively in use or resting in your hand, a pipettemust fit and feel right at all times. Through subtle improvementsto the highly acclaimed Pipet-Lite’s grip, body,finger-hook and surface texture, we’ve made Pipet-Lite XLSour most balanced and comfortable pipette available.Standard features• Ergonomic handle design with comfortable fingerhook• Improved volume adjustment lock prevents drift• Built-in shock absorber inside the tip ejector reducesthumb impact• Autoclavable quick-release tip ejector on all models• Available with LTS, and universal tip/shaft configurationfor use with universal tipsTraditionaltip models MT Order No. Volume RangeSL-2XLS 17011796 0.1–2 µlSL-10XLS 17011792 0.5–10 µlSL-20XLS 17011797 2–20 µlSL-100XLS 17011793 10–100 µlSL-200XLS 17011798 20–200 µl300 0.8 2.4 0.15 0.45L-1000XLS, SL-1000XLS 100 2 3.0 3.0 0.6 0.6500 0.8 4.0 0.2 1.01000 0.8 8.0 0.15 1.0L-2000XLS, SL-2000XLS 200 2 3.0 6.0 0.6 1.21000 0.8 8.0 0.2 2.02000 0.8 16.0 0.12 2.4L-5000XLS, SL-5000XLS 500 5 2.4 12.0 0.6 3.02500 0.6 15.0 0.2 5.0SL-300XLS 17011800 20–300 µl5000 0.6 30.0 0.16 8.0SL-1000XLS 17011794 100–1000 µlSL-2000XLS 17011799 200–2000 µlSL-5000XLS 17011801 500–5000 µlSL-10MLXLS 17011795 1000 µl– 10 mlSL-STARTXLS 17011802 Starter Kits*L-10MLXLS, SL-10MLXLS 1 ml 20 5 50.0 0.6 6.05 ml 1 50.0 0.2 10.010 ml 0.6 60.0 0.16 16.0L-20MLXLS 2 ml 20 5.0 100.0 0.6 12.010 ml 1.0 100.0 0.2 20.020 ml 0.6 120.0 0.16 32.0www.mt.com/rainin12 | 13


RAININ<strong>Rainin</strong> PipettesPipet-Lite XLS MultichannelConsistent on all channels<strong>Rainin</strong>‘s new Pipet-Lite XLS Multichannel is one of themost technically and ergonomically advanced manualmultichannel pipettes available. With our patentedLiteTouch System (LTS ) technology, no multichannelpipette is faster loading, easier on your hand, or deliversmore precise and consistent sample pickup across allchannels. Built rugged and with the finest materialsavailable, our multichannels are designed to deliver yearsof consistent, reliable service. And like all Pipet-Lite XLSmodels, the embedded RFID tag enables advancedcalibration tracking.Pipet-Lite XLS Multichannel with LTSSolves common multichannel problemsAdvanced Functionality• Consistent sample loading across all channels• Easy tip mounting and ejection• Reliable leak-free seal – every time• Improved ergonomic handle design with fingerhook• Improved volume adjustment lock prevents drift• Built-in shock absorber inside the tip ejector reducesthumb impact and stress when ejecting tips• Pipette‘s RFID tags can be queried for asset management• Available in 8 and 12-channel formatsOrdering InformationSpecificationsCat. No. MT Order No. Volume Range8 ChannelL8-10XLS+ 17013802 1–10 µlVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)L8-10XLS+, 1 0.02 2.5 0.025 1.2 0.012L12-10XLS+ 5 1.5 0.075 0.6 0.03Absolute consistency<strong>Rainin</strong>‘s proven LTS nozzle technology promotes faster tipmounting and assures consistent sample loading acrossall channels. LTS’s cylindrical tip design assures a leak-freeseal on each channel. And with no o-rings to break, LTSeliminates a common cause of sample contamination.Fastest tip loadingLTS tips form a perfect seal with minimal force, so they’re aseasy to eject as they are to load. With absolutely no rockingor hand-tightening required, productivity and reliability aresignificantly enhanced.L8-20XLS+ 17013803 2–20 µlL8-50XLS+ 17013804 5–50 µlL8-200XLS+ 17013805 20–200 µlL8-300XLS+ 17013806 20–300 µlL8-1200XLS 17011828 100–1200 µl12 ChannelL12-10XLS+ 17013807 1–10 µlL12-20XLS+ 17013808 2–20 µlL12-50XLS+ 17013809 5–50 µlL12-200XLS+ 17013810 20–200 µl10 1.0 0.1 0.4 0.04L8-20XLS+, 2 0.02 7.5 0.15 2.0 0.04L12-20XLS+ 10 1.5 0.15 0.5 0.0520 1.0 0.2 0.3 0.06L8-50XLS+, 5 0.05 3.5 0.18 1.5 0.075L12-50XLS+ 25 1.2 0.3 0.4 0.150 0.8 0.4 0.2 0.1L8-200XLS+, 20 0.2 2.5 0.5 1.0 0.2L12-200XLS+ 100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3L8-300XLS+, 20 0.5 2.5 0.75 1.0 0.3L12-300XLS+ 150 0.8 1.2 0.25 0.375L12-300XLS+ 17013811 20–300 µl300 0.8 2.4 0.15 0.45L12-1200XLS 17011786 100–1200 µlL8-1200XLS, 100 2 3.6 3.6 0.6L12-1200XLS 600 0.8 4.8 0.2 1.21200 0.8 9.6 0.15 1.8www.mt.com/rainin 14 | 15


RAININ<strong>Rainin</strong> PipettesPipet-Lite XLS Adjustable SpacerSpeeds your work flowSpacingadjustment(dark gray)With its Pipet-Lite XLS Adjustable Spacer, <strong>Rainin</strong> putsa new twist on pipetting: a 6 or 8-channel pipette withadjustable nozzles to quickly transfer liquids from oneformat to another. Its speed, ease and accuracy makeit ideal for Genomic, Proteomic, Tissue Culture andCell Culture applications. For example, aspirate samplesfrom microcentrifuge tubes, turn the spacing knob anddispense into a 24, 48, or 96-well plate. And like allPipet-Lite XLS models, its embedded RFID tag enablesadvanced calibration tracking.Fast spacing changeSet the nozzle spacing between 9and 14 mm (8 channel) or 9 and19 mm (6 channel) to quickly movesamples between different plateand tubing formats. The adjustablespacer is ideally suited for routinemicro-well work when you need tochange formats quickly.Spacing marksLTS tipsLimiter dialLTS shaftnozzlesRepeatable nozzle spacingSet the limiter dial, then movequickly between formats by twistingthe spacing knob to the maximumsetting. A detent on the limiter dialsets the maximum nozzle spacing,so users can move back and forthbetween formats with speed,precision and consistency.Advanced functionality• Fits most standard format plates and tube arrays• Precise nozzle spacing adjustment mechanism for reproducibletip spacing from experiment to experiment• Spacing ranges: 6-channel, 9–19 mm and8-channel, 9–14 mm• Improved volume adjustment lock prevents drift• Available in: 6-channel, 300 and 1200 µl volumes8-channel, 50, 300 and 1200 µl volumes• Suitable for use with 24, 48, 96-well plates,microcentrifuge tubes• Uses LTS tips for consistent pickup.• Pipette‘s RFID tags can be queried for asset managementLTS LiteTouch tip ejection systemThe solution for common multichannel problems• Consistent sample loading• No nozzle o-rings• Lower forces – no more tired handsOrdering InformationCat. No. MT Order No. Volume Range6 ChannelLA6-300XLS 17011840 20-300 µlLA6-1200XLS 17011833 100-1200 µl8 ChannelLA8-50XLS 17011843 5-50 µlLA8-300XLS 17011842 20-300 µlLA8-1200XLS 17011841 100-1200 µlSpecificationsVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)LA8-50XLS 5 0.05 3.5 0.18 1.5 0.07525 1.2 0.3 0.4 0.150 0.8 0.4 0.2 0.1LA6-300XLS, 20 0.5 2.5 0.75 1.0 0.3LA8-300XLS 150 0.8 1.2 0.25 0.375300 0.8 2.4 0.15 0.45LA6-1200XLS, 100 2.0 3.6 3.6 0.60 0.60LA8-1200XLS 600 0.8 4.8 0.20 1.201200 0.8 9.6 0.15 1.80www.mt.com/rainin16 | 17


RAININ<strong>Rainin</strong> PipettesStarter KitsStarter kits and accessoriesGreat for start-up labsChoose Pipet-Lite XLS LTS or traditional-shaft pipette starter kitswith the three most popular models – 20, 200 and 1000 µl.Starter kits also contain 3 racks of tips and pipette Hang-Ups,and you save money.L-START XLSPipet-Lite XLS pipettes:L-20 XLS, L-200 XLS, L-1000 XLSRacks of LTS tips:RT-L10, RT-L250, RT-L1000Hang-Ups: HU-M3SL-START XLSPipet-Lite SL pipettes:SL-20 XLS, SL-200 XLS, SL-1000 XLSRacks of traditional tips:RT-200F, RT-250, RT-1000Hang-Ups: HU-M3www.mt.com/rainin 18 | 19


RAININ<strong>Rainin</strong> PipettesAccessories for Manual PipettesProtect your investmentProtect your high-performance pipettes.From pipette storage options to practicalreservoirs, these accessories help youto make the most of your pipettes.Ordering InformationCat. No. MT Order No. DescriptionHang-Ups, carousel and adaptersHU-M3 17003024 Hang-Ups, magnetic, individual, set of threeHU-S3 17004992 Hang-Ups, Shelf bracket, set of threeHU-A3 17006638 Adapter for Hang-Ups and Carousel, set of threeCR-7 17001255 Carousel Stand holds 7 pipettesCharge stand and power supply6101-049 17004292 Rapid Charge Stand for EDP1E3-RCS 17001755 Rapid Charge Stand for EDP3E3-WPS 17001756 Wall Power Supply for EDP3Filters for large volume pipettes6190-164 17001944 Filters for <strong>Rainin</strong> 5 and 10 mL pipettes 100/pkg6190-165 17001945 Filters for <strong>Rainin</strong> 5 and 10 mL pipettes 1000/pkg6190-221 17001951 Filters for <strong>Rainin</strong> 20 mL pipettes 100/pkg6190-222 17001952 Filters for <strong>Rainin</strong> 20 mL pipettes 500/pkgReagent reservoirsRV-L25 17007886 25 reservoirs 75 ml with lids;presterilized, packaged 5 bags of 5 eachRV-050 17007887 50 reservoirs 75 ml without lids;presterilized, packaged 10 bags of 5 eachHang-Ups Pipette standHU-M3Individual Hang-Ups withmagnets. Adhesive disksincluded for mounting tonon-ferrous surfaces. 3 perpackage.HU-S3Shelf Hang-Ups withoutmagnets. Mounts to lab shelfwith clamp and adjustablescrews. 3 fixed to bracket.CR-7Holds 7 Pipet-Lite XLS, Pos-D,and Pipetman. Rotates for easyaccess. Sturdy base won’t tipover.AdapterIdeal for multichannel and electronicpipettes, the adapter slips easily into aHang-Up (HU-M3) or Carousel Stand(CR-7). No tools are required. 3 perpackage.FiltersThese pipette filters prevent liquids oraerosols from entering the shafts onlarge-volume pipettes.Reagent reservoirsSterile polypropylene reagent reservoirs foruse with single- and multichannel pipettes.Reservoirs are stable and stackable,available with or without lid. Large 75ml capacity with easy-to-read calibrationmarkings.Adapter inHang-UpAvailable with or without lidwww.mt.com/rainin20 | 21


RAININLab Asset ManagementPipette managementsimplified.Intelligent PipettesRFID is “Radio Frequency IDentification” and with nothingmore than <strong>Rainin</strong>’s RFID Reader and LabX DirectPipette-Scan software, you can enhance how your labmanages pipettes. <strong>Rainin</strong>’s pipette management solutionis easy to use and highly adaptable to your workflow.• Scan a pipette’s stored data (calibration andservice, for example) by placing the pipette on theRFID reader• Create custom profiles for each pipette andtransfer that data directly to the pipette’s RFID tag• Integrate your LabX data with third-party assetandcalibration-management applications (LabXdata exports easily as Microsoft ® Excel ® , Word ®or text files)Watch the RFID demowww.mt.com/raininRFIDwww.mt.com/rainin 22 | 23


RAININLab Asset ManagementRFID Reader and LabX SoftwarePipette management simplifiedTransform your workflow with <strong>Rainin</strong>’s Pipet-LiteXLS family of RFID-equipped pipettes. In seconds,everything you want to know about a pipette can bedisplayed on a PC screen. With seemingly endlesspossibilities, <strong>Rainin</strong>’s RFID reader and LabX DirectPipette-Scan software are all you need tocommunicate with any Pipet-Lite XLS.With its speed and ease, <strong>Rainin</strong>’s RFID solution tobetter asset management complements your workflowand instills confidence in your lab’s compliance withSOPs and Regulatory Agencies.Your entire LabX database is exportable to MicrosoftWord, Excel or text format. With such flexibility,LabX data is accessible for spreadsheet and reports,and can be integrated with most any assetmanagement system.• When was this pipette calibrated?• Is it due for service?• Who does it belong to?• What application is it being used for?• Factory Data – Model Number, SerialNumber and Date (Last Service) – issecure and cannot be changed.• Custom data fields canall be renamed.• “Next Calibration” and “Next QuickCheck” are standard fields; all otherUser Data fields are customizable.Scan your pipetteLabX uses the RFID reader to access the pipette’s data.Once scanned, LabX displays the pipette’s complete profile,including serial number, date of manufacture, calibration duedate and any unique attributes assigned.Create custom profilesAssign unique attributes (user, lab, inventory number, etc.) usingLabX’s 12 customizable data fields. Fast access to each pipette’scalibration and service data reduces the possibility of performanceand/or compliance-related rework.Export your dataLabX data easily exports to Microsoft Word and Excel, or as textfor easy integration with other asset management applications.Another <strong>Rainin</strong> innovationRFID tags in every Pipet-Lite XLS help you manage calibrationdata and workflow to optimize your efficiency. A pipetting first!www.mt.com/rainin24 | 25


RAININElectronic PipettesConsistent results,every time, any user.E4 XLS Electronic PipetteAccelerate your workflowWe’ve made it very simple to use the new E4 XLSand kept all the functions you want to see in anelectronic pipette. Renowned <strong>Rainin</strong> accuracy andprecision you’ve come to expect.Fast, easy navigationYou know where you are with the large 16-bitcolor screen. Joystick control with carousel menugets you around the wide range of functions.Accurate and precisePowerful stepper motor with 4000 micro-stepsgives precise control, especially at the lowerrange. It’s remarkably consistent across a widerange of users.Enhanced GLP FunctionalityService data is stored on non-volatile memoryand is protected in the event of power or batteryfailure – assurance for regulated labs. And likeall XLS pipettes, the embedded RFID tag enablesadvanced asset calibration management.Wide range of modelsSingle-channel, 8-channel and 12-channelpipettes in a range of volumes. Also adjustablespacer models in 6 or 8 channels. Fits the needsof every lab.Multi-functional• Basic pipetting• Multidispense• Mixing• Volume sequencing• True Manual mode• Titrationwww.mt.com/rainin 28 | 29


RAININElectronic PipettesE4 XLS Single Channel PipetteThe new standard in electronic pipettingUnparalleled performance and comfort<strong>Rainin</strong>’s E4 XLS is loaded with features, functionalityand a revolutionary new approach to navigation thathas redefined simplicity and control in pipetting. Thecontoured body, even balance and <strong>Rainin</strong>’s legendaryprecision and accuracy all combine to offer an extraordinarypipetting experience. The E4 XLS is alsocompletely upgradeable and expandable right fromyour PC.• Large screen, joystick control and carousel menus speed access to all modes and options• Standard functions include Basic pipetting, Multi-dispense and Mixing• True Manual pipetting mode permits continuous real time control of pipetting speedand direction, combined with precise volume measurement• Advanced functions include sequential volume programming for complex protocols,titration, dilution and reverse mode pipetting• Independent control of aspirate, dispense and mix speeds for challenging liquids• Blowout and automatic dispensing options for precision pipetting protocols• Ergonomic fingerhook and joystick provide maximum comfort• Multilingual display and on-screen Help• Easily accessible service records and alarms• RFID enabled for advanced asset management• Li-Ion battery and Wall Power Supply included• Rapid Charge Stand optional. Charges three pipettes simultaneously in 90 minutesEasy as 1… 2… 3…Whatever your application, the E4 XLS is easy to program and makes setting up protocols fast.For example, here’s how easy it is to program a serial dilution protocol, typically used in qPCR,ELISA and many cell assays:1. Set the total volume to betransferred2. Specify the mixing volume andof mixing cycles3. Set the aspirate, dispense andmix speeds.www.mt.com/rainin 30 | 31


RAININElectronic PipettesE4 XLS Multichannel PipetteSpeed your workflowHigh-throughput pipetting engineFor high-throughput work, nothing compares with theE4 XLS Multichannel. Fast loading, easy to handle andabsolute precision and consistency across all channelsare <strong>Rainin</strong> hallmarks. Increase your productivity andspeed your workflow with our most fully featured andeasiest-to-use electronic pipette available.• Uses LTS tips for consistent sample loading acrossall channels and low tip ejection forces• Large 16-bit color screen, joystick control and carouselmenus speed access to all modes and options• Standard functions include Basic pipetting, Multi-dispense,Mix and True Manual pipetting mode• Advanced functions include sequential volume programmingfor complex protocols, titration, dilution and reversemode pipetting• Independent adjustments for aspirate, dispense and mixspeeds accommodate challenging liquids• Blowout and automatic dispensing options enable precisionpipetting protocols• Ergonomically designed fingerhook and joystick formaximum comfort• Multilingual display and on-screen Help• Easily accessible service records and alarms• RFID enabled for advanced asset management• Li-Ion battery and Wall Power Supply included• Rapid Charge Stand optional. Charges three pipettessimultaneously in one hourConsistent on all channelsLTS’s cylindrical tip design assures fast tip mounting, consistentsample loading and leak-free seals across all channels. Andwith no o-rings to break, LTS eliminates a common causeof sample contamination and volume inconsistency. Perfectfor high throughput applications with precious samples.Simplify repetitive pipettingMulti-dispense takes the drudgery out of repetitive pipetting bycalculating how many aliquots can be dispensed from a singlepickup. Autopace simplifies repeat dispensing – click the joystickonce and repeat dispense across a plate.Watch the E4 XLS demowww.mt.com/raininE4www.mt.com/rainin 32 | 33


RAININElectronic PipettesE4 XLS Adjustable SpacerDifferent formats? Not a problem!Spacingadjustment(dark gray)For high throughput work involving multiple formats,nothing beats <strong>Rainin</strong>’s E4 XLS Adjustable Spacermultichannel pipette for speed and flexibility. Simpleto use, yet loaded with features, the E4 enables you toquickly transfer liquids from one format to another. Itsspeed, ease and legendary accuracy make it ideal forgenomic, proteomic and cell culture applications.Fast spacing changeSet the nozzle spacing between 9and 14 mm (8 channel) or 9 and19 mm (6 channel) to quickly movesamples between different plateand tubing formats. The adjustablespacer is ideally suited for routinemicro-well work when you need tochange formats quickly.Spacing marksLTS tipsLimiter dialLTS shaftnozzlesRepeatable nozzle spacingSet the limiter dial, then movequickly between formats by twistingthe spacing knob to the maximumsetting. A detent on the limiter dialsets the maximum nozzle spacing,so users can move back and forthbetween formats with speed,precision and consistency.Eliminate “speed bumps”Don’t let changing sample formats slow you down. Set thenozzle spacing between 9 and 14 mm (8 channel) or 9 and 19mm (6 channel) and quickly move samples between differentplates and tubes. Perfect for high throughput applications withprecious samples.Enhanced GLP functionalityEasily accessible service data, usage alarms and the E4’slarge, easy to read screen both enhance and complement GLPcompliance. Embedded RFID tags enable advanced assetcalibration and inventory management.www.mt.com/rainin 34 | 35


RAININMultichannel PipettesTechnical DataOrdering informationSpecificationsOrdering informationSpecificationsCat. No. MT Order No. Volume RangeLTS modelsE4-10XLS 17012305 0.5–10 µLE4-20XLS 17012306 2–20 µLVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)10 µl 1.0 0.01 2.5 0.025 1.2 0.0125.0 1.5 0.075 0.6 0.0310.0 1.0 0.1 0.4 0.04Cat. No. MT Order No. Volume Range8 ChannelE8-10XLS+ 17013792 1–10 µlE8-20XLS+ 17013793 2–20 µlVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)10 µl 1 0.01 2.5 0.025 1.2 0.0125 1.5 0.075 0.6 0.0310 1.0 0.1 0.4 0.04E4-100XLS 17012307 10–100 µL20 µl 2 0.02 7.5 0.15 2.0 0.04E8-50XLS+ 17013794 10-100 µl20 µl 2 0.02 7.5 0.15 2.0 0.04E4-200XLS 17012308 20–200 µLE4-300XLS 17012309 20–300 µLE4-1000XLS 17012310 100–1000 µLE4-2000XLS 17012311 200–2000 µLE4-5000XLS 17012312 500–5000 µLE4-10MLXLS 17012313 1-10 mlE4-20MLXLS 17012314 2-20 mlTraditional tip modelsSE4-10XLS 17012346 0.5–10 µL10 1.5 0.15 0.5 0.0520 1.0 0.2 0.3 0.06100 µl 10 0.1 3.5 0.35 1.0 0.150 0.8 0.4 0.24 0.12100 0.8 0.8 0.15 0.15200 µl 20 0.2 2.5 0.5 1.0 0.2100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3300 µl 30 0.2 2.5 0.75 1.0 0.3150 0.8 1.2 0.25 0.375300 0.8 2.4 0.15 0.45E8-200XLS+ 17013795 20–200 µlE8-300XLS+ 17013796 20–300 µlE8-1200XLS 17012326 100–1200 µl12 ChannelE12-10XLS+ 17013797 1–10 µlE12-20XLS+ 17013798 2–20 µlE12-50XLS+ 17013799 10-100 µlE12-200XLS+ 17013800 20–200 µlE12-300XLS+ 17013801 20–300 µl10 1.5 0.15 0.5 0.0520 1.0 0.2 0.3 0.0650 µl 5 0.05 3.5 0.18 1.5 0.07525 1.2 0.3 0.4 0.150 0.8 0.4 0.2 0.1200 µl 20 0.2 2.5 0.5 1.0 0.2100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3300 µl 30 0.2 2.5 0.75 1.0 0.3150 0.8 1.2 0.25 0.375300 0.8 2.4 0.15 0.45SE4-20XLS 17012347 2–20 µL1000 µl 100 1 3.0 3.0 0.6 0.6E12-1200XLS 17012320 100–1200 µl1200 µl 100 1 3.6 3.6 0.6 0.6SE4-100XLS 17012348 10–100 µLSE4-200XLS 17012349 20–200 µLSE4-300XLS 17012350 20–300 µLSE4-1000XLS 17012351 100–1000 µLSE4-2000XLS 17012352 200–2000 µLSE4-5000XLS 17012353 500–5000 µLSE4-10MLXLS 17012354 1-10 mlAccessoriesCat. No. MT Order No. DescriptionE4-RCS 17012332 E4 XLS rapid charge standE4-WPS 17012334 E4 XLS wall power supply500 0.8 4.0 0.2 1.01000 0.8 8.0 0.15 1.52000 µl 200 2 3.0 6.0 0.6 1.21000 0.8 8.0 0.2 2.02000 0.8 16.0 0.12 2.45000 µl 500 5 2.4 12.0 0.6 3.02500 0.6 15.0 0.2 5.05000 0.6 30.0 0.16 8.010 ml 1 ml 10 5 50.0 0.6 6.05 ml 1 50.0 0.2 10.010 ml 60.0 30.0 0.16 16.020 ml 2 ml 20 5.0 100.0 0.6 12.010 ml 1.0 100.0 0.2 20.020 ml 0.6 120.0 0.16 32.0Adjustable spacer modelsCat. No. MT Order No. Volume RangeEA6-300XLS 17012327 20-300 µlEA6-1200XLS 17012328 100-1200 µlEA8-50XLS 17012329 5-50 µlEA8-300XLS 17012330 20-300 µlEA8-1200XLS 17012331 100-1200 µlAccessories600 0.8 4.8 0.2 1.21200 0.8 9.6 0.15 1.8<strong>Rainin</strong>, E4, XLS, and LTS are trademarks of <strong>Rainin</strong> Instrument, LLC.Cat. No. MT Order No. DescriptionE4-RCS 17012332 E4 XLS rapid charge standE4-WPS 17012334 E4 XLS wall power supplyE4-BATT 17012337 E4 XLS batteryE4-USB 17012336 E4 XLS USB cableE4-BATT 17012337 E4 XLS batteryE4-USB 17012336 E4 XLS USB cable<strong>Rainin</strong>, E4, XLS, and LTS are trademarks of <strong>Rainin</strong> Instrument, LLC.www.mt.com/rainin 36 | 37


RAININLiquidator 96The manualmulti-task master.Faster than Many RobotsSimultaneous 96-well manual pipettingLiquidator96 pipetting system is a powerful personallaboratory research tool. With extreme accuracy andefficiency, it maximizes workflow without the need forcomplicated programming or dedicated technician time.Liquidator 96 adds outstanding quality features to highthroughput pipetting with many applications.• Unique manual pipetting system for medium- tohigh-throughput applications• Minimal footprint, fits any lab benchor laminar flow cabinet• Uses 96-well plates and 384-well plates• Simple to use – no programming• Flexible and familiar operation• Fast – for immediate results• Save time and money• Ergonomic, low forcewww.mt.com/rainin38 | 39


RAININLiquidator 96Liquidator Fills 96 WellsQuicker and easierManually pipette into 96 wells simultaneously on a benchtop or in a laminar flow cabinet. No electricity, programmingor complicated robotics are required.Liquidator 96 is completely portable and easily movedbetween labs and benches.METTLER TOLEDO understands that leading edge researchers need fast,reliable equipment in order to become the first to publish, or bring aproduct to the marketplace. Liquidator 96 helps to speed up scientificdiscovery and helps you reach your goals.ApplicationsReplicating/dispensing platesExpression profiling or yeast two hybrid systems.Filling, washing, mixing platesELISA, protein crystallization, screeningsDispensing buffers, master mixesPCR, dilution series among assays.Removing liquids from platesChanging media in cultures.1. Load tipsLiquidator 96 uses LiquidatorLTS tips to ensure consistentpicking on all 96 channels.2. AspirateSimple pull of the handle, easyon the hands.3. DispenseFaster than all other manual pipettingmethods and even many robots,Liquidator 96 can fill a 96-well platein just seconds.‘’We use <strong>Rainin</strong>’s Liquidator 96 for high-throughputapplications. Finding it versatile for many areasof application, we replaced lower capacity pipetteswith Liquidator 96 in PCR, purification andhybridization processes...’’Kay Mekaru / Lab Supervisor Scientific ServicesAffymetrix Research Services LaboratoryWide range of applicationsLiquidator 96 is a unique manual pipetting system formedium- to high-throughput applications:• Plate and mother/daughter replications• Reformatting from 96 to 384 wells and back• Washing and dilution steps• ELISA and other enzyme-based assays• Dispensing PCR buffers and preparing master mixesFast Significantly improves throughput speedEasy As simple as a manual pipetteAccurate Consistently reproducible resultsWatch the Liquidator demowww.mt.com/liq96www.mt.com/rainin40 | 41


RAININLiquidator 96Fast PCR PreparationAbsolutely contamination-freeFaster than other manual pipettes and an effectivealternative to complicated robotic systems. Totalspeed control: fast for rapid filling of master mixinto a PCR plate, slow for delicate and accuratefor expensive samples.Liquidator 96 increases peak efficiency and accuracy whenmanually pipetting into 96- or 384-well plates. Results areconsistent and reliable when using inert, contamination-freeBioClean LTS tips. These tips are manufactured under cleanroom conditions, making them ideal for use in PCR, tissueculture, genetic studies, forensic applications and more.96 and 384 wellsQuick formatting changeLiquidator 96 is ideal for genomic, proteomic and cellularassays. A 96-well plate can be loaded in seconds and a384-well plate in only four passes.FastSpeed your workflowLiquidator fills a 96-well plate in less than 20 seconds –perfect for preparing master mixes and getting a PCR plateinto the thermal cycler fast.Tested and certified tipsInert BioClean tips contain no additives thatmight compromise your results. These tips arefree of RNase, DNase, DNA, Pyrogens, ATP andtrace organics.Reliable results with BioClean tipsBioClean LTS tips provide accurate delivery free fromcontamination for totally reproducible results well-to-welland plate-to-plate.Contaminants testedTesting detection levelsRNase≤ 10-9 Kunitz/µLDNase≤ 10-7 Kunitz/µLDNA< 1 copy human DNAPyrogens 0.001 EU / µLATP< 2 x 10-12 mg/µLwww.mt.com/rainin42 | 43


RAININLiquidator 96Accurate, No-Stress ELISARely on Liquidator 96 reproducibilityStay focused on the true scientific challenges.Liquidator 96 provides new levels of accuracy,precision and control for every type of ELISA assay.When you need highly reproducible and consistent results fromplate-to-plate and well-to-well, rely on the speed and accuracyof pipetting 96 wells at once. In time-critical enzyme-basedassays such as ELISA, all 96 reactions can be started andstopped simultaneously!« »Perfectly timed reactions start andstop simultaneouslyLiquidator 96 is vital for time-criticalassays, such as ELISA, as reactionsin all wells can be started and stoppedat precisely the same time. No morerushing or well-to-well variability.Error free – all wells filled precisely<strong>Rainin</strong> Liquidator LTS tips guaranteeabsolutely consistent pickup. Whateverthe dial is set to is exactly what is pickedup in the tip with no variability betweenchannels. All wells are filled with exactlythe same sample volume.Flexible sample preparationwith adjustable spacer pipetteUse <strong>Rainin</strong>’s adjustable spacermultichannel pipettes to move samplesbetween different format vials, tubesand plates with efficiency and precision.Consistent volume deliveryThis graph of actual data from a Liquidator 96dispensing into a 96-well plate illustrates how allsample volumes are within a range of ± 0.5%.200.00 - 200.50199.50 - 200.00www.mt.com/rainin 44 | 45


RAININLiquidator 96Liquidator 96Fast manual benchtop systemIncredibly fast, Liquidator 96 is ideal for many applications:genomics, proteomics, and general plate replication, plate fillingbetween 96 and 384 wells, wash and dilution steps in variousassays. Designed for ultimate performance, precision, andaccuracy, Liquidator 96 ensures reproducible results fromwell-to-well and plate-to-plate.Optimize your Investment with IPac<strong>Rainin</strong>’s IPac Initial Qualification is a comprehensivesolution to all of your installation needs: installation,configuration, calibration, training and verification.The IPac procedure should be performed with a newLiquidator installation, when an existing Liquidatorneeds to be moved and for equipment that has notbeen previously verified. IPac Qualification covers:• Proper Installation• Optimized Configuration• Initial Calibration and Function Test• Employee Training• Documented Regulatory ComplianceOrdering informationSaves time and moneyFaster than all other manual pipettingsystems and even expensive 4- and8-channel robots. Uses SBS footprint96-well or 384-well plates.Liquidator 96 is mobile and compact,and can be used anywhere, includinglaminar flow cabinets.Accurate and preciseRugged monoblock base plate, strictproduction tolerances, and high qualitytooling provide a stable platform foraccuracy and precision across the wholevolume range. Lockable volume settingprevents drift.Ready to goReady for immediate use by anyone,whether experienced or new to theinstrument. Intuitive, requires noexpensive operator training, softwarecompliance, or even electricity, andnever any bottle-necks waiting forprograms to finish.Cat. No. MT Order No. DescriptionLiquidator 96LIQ-96-200 17010335 96-channel Manual Benchtop Pipetting System 1-200 µlLIQ-IPAC 17012282 IPac Initial Qualification for Liquidator 96LIQ-SVC 17010622 Annual Liquidator Service PlanLIQ-SVC4 17010753 4-year Service PlanLIQ-SVC4-B 17011290 4-year Service Plan with as-found dataCat. No. MT Order No. DescriptionVolume RangeBioClean Liquidator racked tipsLQR-20 17011185 Liquidator 96 Tips, Racked 1-20 µlLQR-20S 17011186 Liquidator 96 Tips, Racked, Presterilized 1-20 µlLQR-20F 17011117 Liquidator 96 Tips, Filter, Racked 1-20 µlLQR-200 17010645 Liquidator 96 Tips, Racked 5-200 µlLQR-200S 17010647 Liquidator 96 Tips, Racked, Presterilized 5-200 µlAccessoriesLIQ-384PA 17010394 384-well adapter plate stageLQR-200F 17010646 Liquidator 96 Tips, Filter, Racked 5-200 µlBioClean Liquidator stacked tipsLIQ- 384PA-B 17010791 384-well adapter plate stage - blackLQR-20 17011187 Liquidator 96 Tips, Stacked 1-20 µlLIQ-AP 17010396 Height adjustment postsLQR-20S 17011287 Liquidator 96 Tips, Stacked, Presterilized 1-20 µlLIQ-MAG1 17011288 Magnetic bead separator plate, 24 postsLQS-200 17010648 Liquidator 96 Tips, Stacked 5-200 µlLIQ-MAG2 17011289 Magnetic bead separator plate, 96 round postsLQS-200S 17010649 Liquidator 96 Tips, Stacked, Presterilized 5-200 µlLIQ-20PA* 17011118 20 µl tip adapter plate stage - whiteLIQ-20PA-B* 17011119 20 µl tip adapter plate stage - black*One of these stages must be used w/ 20 µl tipswww.mt.com/rainin46 | 47


RAININBioClean TipsClean, inert pipettetips.<strong>Rainin</strong>’s Tip Manufacturing FacilityDesigned to deliver the cleanest tips<strong>Rainin</strong>’s rigorously clean Class 100K manufacturingfacility ensures an absence of contamination throughoutthe manufacturing environment. Full automation eliminatesany possibility of human contact with the tips andresults in a pristine product without any detectable traceof biological contamination.Automated material handlingHigh-capacity vacuum pumps to transfer virgin polypropylenepellets from stainless steel silos to the injection moldingmachines. Then, to ensure product cleanliness, <strong>Rainin</strong>’s innovativeracker system automatically places the tips in the racks,eliminating all human contact during the manufacturing process.Clean room environmentMore than 20,000 sq. ft. of clean rooms specially designed fortip production and packaging. HEPA filters and positive pressureensure contaminants do not enter the tip production area.Staff procedures and training<strong>Rainin</strong> manufacturing personnel wear masks, gloves and hairnets to reduce the risk of introducing contamination to the tipmanufacturing environment.Rigorous quality assurance testingStatistically relevant quantities of newly molded tips arecontinuously sampled from the production line and subjectedto rigorous quality testing. Sampling occurs throughout the dayat a minimum frequency of once every four hours. Every tippackaged is subjected to 100% visual inspection.CertificationFiltered and presterilized bioclean tips are sterilized by gammairradiation and certified.Protecting sample integrityClean pipette tips are critical in life science researchTo ensure high quality lab results, tips coming into contact with samples must be freeof DNase, RNase, DNA, pyrogen and adenosine triphosphate (ATP). Understanding thesetypical sample contaminants and taking precautionary measures to reduce or eliminatethem at their source is vital to protecting sample integrity.Contamination originates both in and out of the labHuman contact is the primary source of contamination. Poor handling procedures cancompromise tip purity. The manufacturing process and tip packaging environment areother potential contamination sources that should not be overlooked.How can contaminants be reduced or eliminated?Laboratory personnel typically employ a set of procedures to minimize sources ofcontamination in the lab. But because sample contaminants can originate outside thelab, it is important to evaluate what controls have been put into place at the productionlevel, to assure that possible risk factors have been reduced or eliminated before theproduct arrives in the lab.50 | 51


RAININBioClean TipsBioClean Tips TechZoneContamination-free performanceThrough innovative design and high-quality production,high-grade <strong>Rainin</strong> BioClean tips ensure optimal pipettingperformance. Manufactured under clean-room conditions,these inert tips are 100% contamination-free, preventingexperiment inconsistencies and compromised data fidelity.<strong>Rainin</strong> BioClean TipsWith a wide array of tips, in a variety of feature-sets, volumeranges and packaging options, scientists can always work withthe optimal application-specific pipetting system. LTS LiteTouch and traditional-shaft designs.BioClean production – no contaminationTo ensure high quality lab results, tips must be inert and free ofDNase, RNase, DNA, pyrogen and adenosine triphosphate (ATP).<strong>Rainin</strong> puts great focus on BioClean production by eliminatinghuman contact wherever possible. Our tips are clean.Perfect production – flawless tip geometryVirgin polypropylene material and state-of-the-art manufacturingresult in flawless <strong>Rainin</strong> tips. No deformation, cracking, flash,just perfect tip geometry.FinePoint – thin walls for complete liquid transferPipetting accuracy demands an ability to completely dispense theliquid sample from the pipette tip. FinePoint tips feature an acutelytapered design, coupled with very thin tip walls. This results in asubtle, highly flexible pipette tip. The exceedingly thin wall at theorifice end of the tip prevents residual amounts of fluid from clingingto the end of the tip during dispensing. When drawn againstthe wall of a vessel, the FinePoint design allows for completetouch-off and discharge of the last trace of fluid from the tip.Ecologically friendlyInnovative packaging solutions for tip rack refilling significantlyreduce plastic waste.Certified contamination-freeBioClean filter and presterilized tips are gamma irradiated toguarantee product sterility. Tested in both internal and externallabs, these tips are certified free of DNase, RNase, DNA, pyrogensand ATP. A test certificate is included in each package.Highest qualityVirgin polypropylene. State-of-the-art manufacturing.Large VarietyThe large selection of available sizes, packaging options, andtechnical variations provides the ideal tool for every application.High quality production• BioClean tips and packaging: contamination-free• Flawless tip geometryInnovative designs• LTS LiteTouch System• Space Saver reduces plastic waste and lab cutterWide selection of tips• Optimized, application – specific tip designs• Many volume ranges• Green packaging optionswww.mt.com/rainin52 | 53


RAININBioClean TipsAerosol Resistant TipsProtection against aerosol contaminationSpecialty TipsFor specialized research<strong>Rainin</strong>’s Aerosol Resistant tips are your best choice for preventing aerosolsand liquids in the tip from reaching and contaminating the pipette shaft.Effective in preventing sample cross-contamination in all PCR-basedapplications, such and genotyping, qPCR and forensic analyses.Piston250 μl LTS Tips 1000 μl LTS TipsStandard Extended Standard ExtendedLow-retention LTS tipGeneric tipPipette ShaftAerosol-FreeFilterAerosolsSampleContaminants TestedRNaseDNaseDNAPyrogens (LAL test)ATPTesting Detection Levels10 -9 Kunitz units/µl10 -7 Kunitz units/µl1 copy human DNA0.001 EU/ml10 -12 mg/µlMinimal retentionof dense sampleDense sample bindingin low-quality tipsWithout FilterWith FilterHydrophobic filter eliminates contaminationHydrophobic filter forms a barrier against aerosols and liquids,eliminating potential sample and pipette cross-contaminationthat could jeopardize results.Pure polyethylene filters contain no additivesThe filters in <strong>Rainin</strong>’s aerosol-resistant tips are comprised of anexceptionally dense matrix of sintered polyethylene particles.Unlike other filter types contain additives that can inhibit enzymaticreactions, <strong>Rainin</strong> filters are composed of pure polyethylene.These sintered particles form a hydrophobic, tortuous path matrix(average pore size: 40 µm) that prevent aerosols and liquidsfrom being aspirated into the body of the pipette.CertificationFiltered and presterilized bioclean tips are gamma-radiated toensure the packaged product is completely sterile. In addition,each tip lot is process-tested to specifications shown here andlabeled “Certified free of DNase, RNase, DNA, pyrogen, and ATP.”A test protocol certificate is included in each package.Extended-length tipsFor pipetting into tall narrow tubes102 mm long<strong>Rainin</strong> extended-length LTS tips will reach to the bottom ofblocks, tall vials, flasks, 100 mm tubes, etc.Narrow diameterThese tips will pass through 8 mm ID penetrable septa, suchas on the Gen-Probe APTIMA specimen collection kits.Reach the bottom of these vials easily, without the pipetteshaft touching the vessel wall and becoming contaminated.Racked for convenienceSupplied in racks, standard, presterilized and withaerosol-resistant filters. RT-L1000X and RT-L1000XS tipshold a full 1200 μl volume.Low-retention tipsFor pipetting proteins, enzymes and DNAUltra-hydrophobicityUnlike other companies that dip or coat their tips, <strong>Rainin</strong> employsa special molding process to integrate a fluoropolymer additivehomogeneously throughout the entire tip. This avoids problemsassociated with inconsistent and incomplete coatings. Theexposed trifluoromethyl additive reduces interaction between theaspirated liquid and the polypropylene tip matrix, resulting inan exceptionally hydrophobic tip surface that is not affected byautoclaving. Available in 10, 250 and 1,000 µl LTS tip volumes.Low-retention tips perform better with demanding samplesEnsure higher pipetting accuracy and reproducibility, even whenworking with viscous, tenacious samples. Greater pipettingaccuracy means less of your valuable samples are wasted.Gen-Probe ® and APTIMA ® are registered trademarks of Gen-Probe Inc.www.mt.com/rainin54 | 55


RAININBioClean TipsStableStak and StableRak Maximum stability for multichannel workChoose the most efficientdouble-96 format productfor your application.<strong>Rainin</strong>’s unique Double-96 format systems have beendesigned for multichannel, high-production environments.Each layer contains 192 easy-loading tips, and rubberfeet prevent skidding. Ideal for working in hoods or otherconfined pipetting environments.StableStak – multilayer stacksSave space, get 60% less waste!• One StableStak (960 tips in 5 layers) replacesten 96-place racks• Each layer has 192 tips ready for use at once!• Available in filter, presterilized, and standardin 10, 250, 300, 1000, and 1200 µl volumesStableRak – individual racksIdeal for filter-tip users, 35% less waste• Contains 192 tips in one rack• Five StableRaks (960 tips) replace ten 96-place racks• Available in standard and presterilizedin 10, 250, 300, and 100 µl volumesEasiest to use Deep-well for quick tip mountingStable Non-skid rubber feet keep the racks in placeRigid Strong flat trays for even tip loadingDouble-96 format Saves time, increases productivitywww.mt.com/rainin60 | 61


RAININBioClean TipsLTS Tips for <strong>Rainin</strong> LTS PipettesCat. No. MT Order No. DescriptionMaximumCapacity Fits LTS Pipette TypeCat. No. MT Order No. DescriptionMaximumCapacity Fits LTS Pipette TypeRemovable-cover racksRT-L10 17002930 960 tips in 10 racks 20 μl 2, 10, 20 μlRT-L10S 17002929 960 tips in 10 racks 20 μl 2, 10, 20 μl PresterilizedRT-L10F 17002928 960 tips in 10 racks 20 μl 2, 10, 20 μl Filter, presterilizedRT-L250 17002932 960 tips in 10 racks 200 μl 50,100, 200 μlRT-L250S 17002931 960 tips in 10 racks 200 μl 50,100, 200 μl PresterilizedRT-L200F 17002927 960 tips in 10 racks 200 μl 50,100, 200 μl Filter, presterilizedRT-L250W 17007102 960 tips in 10 racks 200 μl 50,100, 200 μl Wide-orificeRT-L250WS 17007101 960 tips in 10 racks 200 μl 50,100, 200 μl Wide-orifice, presterilizedRT-L300 17002935 768 tips in 8 racks 300 μl 300 μlRT-L300S 17002934 768 tips in 8 racks 300 μl 300 μl PresterilizedRT-L300F 17002933 768 tips in 8 racks 300 μl 300 μl Filter, presterilizedRT-L1000 17002922 768 tips in 8 racks 1000 μl 1000 μlRT-L1000S 17002921 768 tips in 8 racks 1000 μl 1000 μl PresterilizedRT-L1000F 17002920 768 tips in 8 racks 1000 μl 1000 μl Filter, presterilizedRT-L1000W 17007100 768 tips in 8 racks 1000 μl 1000 μl Wide-orificeRT-L1000WS 17007099 768 tips in 8 racks 1000 μl 1000 μl Wide-orifice, presterilizedRT-L1200 17006421 768 tips in 8 racks 1200 μl 1200, 1000 μlRT-L1200S 17006420 768 tips in 8 racks 1200 μl 1200, 1000 μl PresterilizedRT-L1200F 17006419 768 tips in 8 racks 1200 μl 1200, 1000 μl Filter, presterilizedRT-L2000 17002926 480 tips in 8 racks 2000 μl 2000 μlRT-L2000S 17002924 480 tips in 8 racks 2000 μl 2000 μl PresterilizedRT-L2000F 17002923 480 tips in 8 racks 2000 μl 2000 μl Filter, presterilizedRT-L5000 17002937 192 tips in 8 racks 5000 μl 5000 μlRT-L5000S 17002936 192 tips in 8 racks 5000 μl 5000 μl PresterilizedGreen-PakGP-L10 17002424 960 tips in 10 refills 20 μl 2, 10, 20 μlGP-L10S 17002430 960 tips in 10 refills 20 μl 2, 10, 20 μl PresterilizedGP-L10F 17002429 960 tips in 10 refills 20 μl 2, 10, 20 μl Filter, presterilizedGP-L250 17002425 960 tips in 10 refills 200 μl 50,100, 200 μlGP-L250S 17002431 960 tips in 10 refills 200 μl 50,100, 200 μl PresterilizedGP-L200F 17002428 960 tips in 10 refills 200 μl 50,100, 200 μl Filter, presterilizedGP-L1000 17002423 768 tips in 8 refills 1000 μl 1000 μlGP-L1000S 17002427 768 tips in 8 refills 1000 μl 1000 μl PresterilizedGP-L1000F 17002426 768 tips in 8 refills 1000 μl 1000 μl Filter, presterilizedGPR-L10 17001865Empty racks/lids for any GP/GPS 10 μl refills, red, package of 10GPR-L250 17001861Empty racks/lids for any GP/GPS 250 μl refills, green, package of 10GPR-L1000 17001864Empty racks/lids for any GP/GPS 1000 μl refills, blue, package of 8Green-Pak SpaceSaverGPS-L10 17005091 960 tips in 10 refills 20 μl 2, 10, 20 μlGPS-L10S 17005090 960 tips in 10 refills 20 μl 2, 10, 20 μl PresterilizedGPS-L250 17005093 960 tips in 10 refills 200 μl 50,100, 200 μlGPS-L250S 17005092 960 tips in 10 refills 200 μl 50,100, 200 μl PresterilizedGPS-L300 17005095 768 tips in 8 refills 300 μl 300 μlGPS-L300S 17005094 768 tips in 8 refills 300 μl 300 μl PresterilizedGPS-L1000 17005089 768 tips in 8 refills 1000 μl 1000 μlGPS-L1000S 17005088 768 tips in 8 refills 1000 μl 1000 μl PresterilizedExtended-length tipsRT-L250X 17008814 768 tips in 8 racks 200 μl 50,100, 200 μlRT-L250XS 17008815 768 tips in 8 racks 200 μl 50,100, 200 μl Presterilized, ext lengthRT-L200XF 17008887 768 tips in 8 racks 200 μl 50,100, 200 μl Filter, presterilized, ext lengthRT-L1000X 17008817 768 tips in 8 racks 1200 μl 1000, 1200 μlRT-L1000XS 17008818 768 tips in 8 racks 1200 μl 1000, 1200 μl Presterilized, ext lengthRT-L1000XF 17008819 768 tips in 8 racks 1200 μl 1000, 1200 μl Filter, presterilizedLow-retention tipsRT-L10LR 17007955 960 tips in 10 racks 20 μl 2, 10, 20 μl Low-retentionRT-L10SLR 17007956 960 tips in 10 racks 20 μl 2, 10, 20 μl Presterilized, low-ret.RT-L10FLR 17007957 960 tips in 10 racks 20 μl 2, 10, 20 μl Filter, presterilized, low-ret.RT-L250LR 17007959 960 tips in 10 racks 200 μl 50,100, 200 μl Low-retentionRT-L250SLR 17007960 960 tips in 10 racks 200 μl 50,100, 200 μl Presterilized, low-ret.RT-L200FLR 17007961 960 tips in 10 racks 200 μl 50,100, 200 μl Filter, presterilized, low-ret.RT-L1000LR 17007952 768 tips in 8 racks 1000 μl 1000 μl Low-retentionRT-L1000SLR 17007953 768 tips in 8 racks 1000 μl 1000 μl Presterilized, low-ret.RT-L1000FLR 17007954 768 tips in 8 racks 1000 μl 1000 μl Filter, presterilized, low-ret.StableRak double-96 format individual racksSR-L10 17005862 960 tips in 5 racks 20 μl 2, 10, 20 μlSR-L10S 17005861 960 tips in 5 racks 20 μl 2, 10, 20 μl PresterilizedSR-L10F 17005860 960 tips in 5 racks 20 μl 2, 10, 20 μl Filter, presterilizedSR-L250 17005864 960 tips in 5 racks 200 μl 50,100, 200 μlSR-L250S 17005863 960 tips in 5 racks 200 μl 50,100, 200 μl PresterilizedSR-L200F 17005859 960 tips in 5 racks 200 μl 50,100, 200 μl Filter, presterilizedSR-L300 17005867 768 tips in 4 racks 300 μl 300 μlSR-L300S 17005866 768 tips in 4 racks 300 μl 300 μl PresterilizedSR-L300F 17005865 768 tips in 4 racks 300 μl 300 μl Filter, presterilizedSR-L1000 17007083 768 tips in 4 racks 1000 μl 1000 μlSR-L1000S 17007082 768 tips in 4 racks 1000 μl 1000 μl PresterilizedSR-L1000F 17007081 768 tips in 4 racks 1000 μl 1000 μl Filter, presterilizedSR-L1200 17007086 768 tips in 4 racks 1200 μl 1200, 1000 μlSR-L1200S 17007085 768 tips in 4 racks 1200 μl 1200, 1000 μl PresterilizedSR-L1200F 17007084 768 tips in 4 racks 1200 μl 1200, 1000 μl Filter, presterilizedStableStak double-96 format stacked racksSS-L10 17005873 960 tips in 5 layers 20 μl 2, 10, 20 μlSS-L10S 17005872 960 tips in 5 layers 20 μl 2, 10, 20 μl PresterilizedSS-L250 17005875 960 tips in 5 layers 200 μl 50,100, 200 μlSS-L250S 17005874 960 tips in 5 layers 200 μl 50,100, 200 μl PresterilizedSS-L300 17005877 768 tips in 4 layers 300 μl 300 μlSS-L300S 17005876 768 tips in 4 layers 300 μl 300 μl PresterilizedSS-L1000 17007090 768 tips in 4 layers 1000 μl 1000 μlSS-L1000S 17007089 768 tips in 4 layers 1000 μl 1000 μl PresterilizedBulk tipsRC-L10 17001128 1000 tips in bags 20 μl 2, 10, 20 μlRC-L250 17001118 1000 tips in bags 200 μl 50,100, 200 μlRC-L300 17001132 1000 tips in bags 300 μl 300 μlRC-L1000 17001129 1000 tips in bags 1000 μl 1000 μlRC-L1200 17006324 1000 tips in bags 1200 μl 1200,1000 μlRC-L2000 17001130 1000 tips in bags 2000 μl 2000 μlRC-L5000 17001133 1000 tips in bags 5000 μl 5000 μlRC-L10ML 17001119 200 tips in bags 10 ml 10 mlRC-L10MLS 17005940 75 tips individ. wrapped 10 ml 10 ml Presterilized, individ. wrappedRC-L20ML 17001131 100 tips in bags 20 ml 20 mlRC-L20MLS 17005941 50 tips individ. wrapped 20 ml 20 ml Presterilized, individ. wrappedwww.mt.com/rainin 62 | 63


RAININBioClean TipsTraditional TipsCat. No. MT Order No. DescriptionMaximumCapacityFits TraditionalPipette ModelTypeCat. No. MT Order No. DescriptionMaximumCapacityFits TraditionalPipette ModelTypeRemovable-cover racksRT-10 17002896 960 tips in 10 racks 10 μl 2, 10 μlRT-10S 17002905 960 tips in 10 racks 10 μl 2, 10 μl PresterilizedRT-10F 17002904 960 tips in 10 racks 10 μl 2, 10 μl Filter, presterilizedRT-10G 17002908 960 tips in 10 racks 10 μl 2, 10 μl ShaftGardRT-10GS 17002907 960 tips in 10 racks 10 μl 2, 10 μl ShaftGard / PresterilizedRT-10GF 17002906 960 tips in 10 racks 10 μl 2, 10 μl ShaftGard / FilterRT-20F 17002917 960 tips in 10 racks 30 μl 20, 25 μl Filter, presterilizedRT-100F 17002903 960 tips in 10 racks 100 μl 100 μl Filter, presterilizedRT-250 17002916 960 tips in 10 racks 250 μl 20, 25, 100, 200, 250 μlRT-250S 17002913 960 tips in 10 racks 250 μl 20, 25, 100, 200, 250 μl PresterilizedRT-200F 17002912 960 tips in 10 racks 200 μl 200, 250 μl Filter, presterilizedRT-1000 17002902 768 tips in 8 racks 1000 μl 1000 μlRT-1000S 17002901 768 tips in 8 racks 1000 μl 1000 μl PresterilizedRT-1000F 17002897 768 tips in 8 racks 1000 μl 1000 μl Filter, presterilizedRT-2000 17002911 480 tips in 8 racks 2000 μl 2000, 2500 μlRT-2000S 17002910 480 tips in 8 racks 2000 μl 2000, 2500 μl PresterilizedRT-2000F 17002909 480 tips in 8 racks 2000 μl 2000, 2500 μl Filter, presterilizedRT-5000 17002919 192 tips in 8 racks 5000 μl 5000 μlRT-5000S 17002918 192 tips in 8 racks 5000 μl 5000 μl PresterilizedGreen-PakGP-10 17002419 960 tips in 10 refills 10 μl 2, 10 μlGP-10S 17002415 960 tips in 10 refills 10 μl 2, 10 μl PresterilizedGP-10F 17002414 960 tips in 10 refills 10 μl 2, 10 μl Filter, presterilizedGP-10G 17002418 960 tips in 10 refills 10 μl 2, 10 μl ShaftGardGP-10GS 17002417 960 tips in 10 refills 10 μl 2, 10 μl ShaftGard / PresterilizedGP-10GF 17002416 960 tips in 10 refills 10 μl 2, 10 μl ShaftGard / FilterGP-20F 17002422 960 tips in 10 refills 30 μl 20, 25 μl Filter, presterilizedGP-100F 17002413 960 tips in 10 refills 100 μl 100 μl Filter, presterilizedGP-250 17002409 960 tips in 10 refills 250 μl 20, 25, 100, 200, 250 μlGP-250S 17002421 960 tips in 10 refills 250 μl 20, 25, 100, 200, 250 μl PresterilizedGP-200F 17002420 960 tips in 10 refills 200 μl 200, 250 μl Filter, presterilizedGP-1000 17002412 768 tips in 8 refills 1000 μl 1000 μlGP-1000S 17002411 768 tips in 8 refills 1000 μl 1000 μl PresterilizedGP-1000F 17002410 768 tips in 8 refills 1000 μl 1000 μl Filter, presterilizedGPR-10 17001860Empty racks/ lids for GP-10 products, Purple, pkg of 10GPR-10G 17001862Empty racks/ lids for GP-10G, GPS-10G products, Red, pkg of 10, ShaftGardGPR-250 17001861Empty racks/ lids for GP-250, GPS-250 products, Green, pkg of 10GPR-1000 17001859Empty racks/ lids for GP-1000, GPS-1000 products, Blue, pkg of 8Green-Pak SpaceSaverGPS-10G 17005085 960 tips in 10 refills 10 μl 2, 10 μl ShaftGardGPS-10GS 17005084 960 tips in 10 refills 10 μl 2, 10 μl ShaftGard / PresterilizedGPS-250 17005087 960 tips in 10 refills 250 μl 20, 25, 100, 200, 250 μlGPS-250S 17005086 960 tips in 10 refills 250 μl 20, 25, 100, 200, 250 μl PresterilizedGPS-1000 17005083 768 tips in 8 refills 1000 μl 1000 μlGPS-1000S 17005082 768 tips in 8 refills 1000 μl 1000 μl PresterilizedStableStakSS-250 17005869 960 tips in 5 layers 250 μl 20, 25, 100, 200, 250 μlSS-250S 17005868 960 tips in 5 layers 250 μl 20, 25, 100, 200, 250 μlSS-300 17005871 768 tips in 4 layers 300 μl 300 μlSS-300S 17005870 768 tips in 4 layers 300 μl 300 μl PresterilizedSS-1000 17007088 768 tips in 4 layers 1000 μl 1000 μlSS-1000S 17007087 768 tips in 4 layers 1000 μl 1000 μl PresterilizedStableRakSR-20F 17005858 960 tips in 5 racks 30 μl 20, 25 μl Filter, presterilizedSR-100F 17005851 960 tips in 5 racks 100 μl 100 μl Filter, presterilizedSR-250 17005854 960 tips in 5 racks 250 μl 20, 25, 100, 200, 250 μlSR-250S 17005853 960 tips in 5 racks 250 μl 20, 25, 100, 200, 250 μl PresterilizedSR-200F 17005852 960 tips in 5 racks 200 μl 200 μl Filter, presterilizedSR-300 17005857 768 tips in 4 racks 300 μl 300 μlSR-300S 17005856 768 tips in 4 racks 300 μl 300 μl PresterilizedSR-300F 17005855 768 tips in 4 racks 300 μl 300 μl Filter, presterilizedSR-1000 17007080 768 tips in 4 racks 1000 μl 1000 μlSR-1000S 17007079 768 tips in 4 racks 1000 μl 1000 μl PresterilizedSR-1000F 17007078 768 tips in 4 racks 1000 μl 1000 μl Filter, presterilizedHinged-Cover racks and refillsHR-20F 17002486 960 tips in 10 racks 30 μl 20, 25 μl Filter, presterilizedHR-100F 17002481 960 tips in 10 racks 100 μl 100 μl Filter, presterilizedHR-250 17002485 960 tips in 10 racks 250 μl 20, 25, 100, 200, 250 μlHR-250S 17002484 960 tips in 10 racks 250 μl 20, 25, 100, 200, 250 μl PresterilizedHR-200F 17002483 960 tips in 10 racks 200 μl 200, 250 μl Filter, presterilizedHR-1000 17002480 1000 tips in 10 racks 1000 μl 1000 μlHR-1000S 17002482 1000 tips in 10 racks 1000 μl 1000 μl PresterilizedHR-1000F 17002479 1000 tips in 10 racks 1000 μl 1000 μl Filter, presterilizedRR-250 960 tips in 10 refills 250 μl 20, 25, 100, 200, 250 μlRR-1000 1000 tips in 10 refills 1000 μl 1000 μlSpecialty tipsGT-10-2 17002375 200 tips in 1 rack 10 μl 2, 10 μl Gel-Well, 0.17 mmGT-10-4 17002377 200 tips in 1 rack 10 μl 2, 10 μl Gel-Well, 0.37 mmGT-10-6 17002380 200 tips in 1 rack 10 μl 2, 10 μl Gel-Well, 0.57 mmGT-250-2 17002376 200 tips in 1 rack 250 μl 20, 25, 100, 200, 250 μl Gel-Well, 0.17 mmGT-250-4 17002378 200 tips in 1 rack 250 μl 20, 25, 100, 200, 250 μl Gel-Well, 0.37 mmGT-250-6 17002379 200 tips in 1 rack 250 μl 20, 25, 100, 200, 250 μl Gel-Well, 0.57 mmRC-250W 17001127 1000 tips in bags 250 μl 20, 25, 100, 200, 250 μl Wide-orificeHR-250W 17005716 960 tips in 10 racks 250 μl 20, 25, 100, 200, 250 μl Wide-orificeHR-250WS 17005715 960 tips in 10 racks 250 μl 20, 25, 100, 200, 250 μl Wide-orifice / PresterilizedHR-1000W 17005714 1000 tips in 10 racks 1000 μl 1000 μl Wide-orificeHR-1000WS 17005713 1000 tips in 10 racks 1000 μl 1000 μl Wide-orifice / PresterilizedClassic racksRT-20 17002915 1000 tips in 10 rack 250 μl 20, 25, 100, 200, 250 μlRT-20S 17002914 1000 tips in 10 rack 250 μl 20, 25, 100, 200, 250 μl PresterilizedRT-200 17002898 1000 tips in 10 rack 1000 μl 1000 μlRT-200S 17002900 1000 tips in 10 rack 1000 μl 1000 μl PresterilizedRT-200F3 17002899 1000 tips in 10 rack 1000 μl 1000 μl Filter, presterilizedBulk tipsRC-10 17001124 1000 tips in bags 10 μl 2, 10 μlRC-10G 17001123 1000 tips in bags 10 μl 2, 10 μl ShaftGardRC-250 17001116 1000 tips in bags 250 μl 20, 25, 100, 200, 250 μlRC-200 17001120 1000 tips in bags 1000 μl 1000 μl Non-finepointRC-1000 17001121 1000 tips in bags 1000 μl 1000 μlRC-2000 17001125 1000 tips in bags 2000 μl 2000, 2500 μlRC-2500 17001126 1000 tips in bags 2500 μl 2500 μlRC-5000 17001117 1000 tips in bags 5000 μl 5000 μlRC-10ML 17001122 200 tips in bags 10 ml 10 mlRC-10MLS 17005939 75 tips individ. wrapped 10 ml 10 mlwww.mt.com/rainin64 | 65


RAININSpecialty ProductsThe right tool forevery application.Specialty ProductsEnhance your workflow<strong>Rainin</strong>’s selection of pipettes and tips covers mostlab applications, but sometimes a specialty tool ispreferable. Pipetting viscous or volatile liquids,repeat dispensing, transferring aggressive liquidssafely or serological pipetting – these are tasks thatare best served by our specialized products.Pos-DProblem-free pipetting of problem liquids.AutoRep RepeaterRepetitive pipetting.Pipet-XFor use with disposable glass and plastic pipets.Disp-XHandle reagents safely and easily.LiteTouch TubesUnique opening method – better ergonomics andno contamination.Special products for special applicationsPositive-displacement pipetteSpecially suited for liquid samples with high densities, viscositiesor vapor pressures. Absolutely eliminates cross-contaminationfrom aerosols, samples or pipette.Repeater pipetteSpeed up long pipetting series. Positive displacement syringes forvolumes from 1 μl – 50 ml. Electronic and manual versions.Pipet controllerLightweight, easy to use, three speeds. Uses standard serologicalpipets. Electronic and manual versions.Bottle-top dispenserBuilt-in safety features protect the user from accidental spills andensure smooth, trouble-free operation.Microcentrifuge tubes 1.7 mlOne-handed operation, easy to use, colored and natural tubes.www.mt.com/rainin 66 | 67


RAININSpecialty Products<strong>Rainin</strong> ClassicTraditional pipette with ergonomic benefitsBased on the look, feel and handling of traditional pipettes, <strong>Rainin</strong>Classic provides years of reproducible performance. Lighter spring forces,low-drag seals and a shock absorber make it easier on your hands.DurableStainless steel and quality PVDF ensure fewer out-of-tolerance failures,many years of performance with low cost of ownership. Simple maintenance.No lubrication.Lower plunger forceLighter aspiration and blowout springs reduce pain and injury.Plunger force in <strong>Rainin</strong> Classic is 25% less than in similar traditional pipettes.Comfortable finger-hookThe ergonomically designed finger-hook allows you to rest the handand use a lighter grip during pipetting cycles.Silicone shock absorberThe silicone shock absorber in the tip ejector provides extra protectionby reducing impact forces when ejecting tips.Pos-D Positive Displacement PipetteProblem-free pipetting of problem liquidsPos-D is specially suited for liquids with high densities, viscositiesor vapor pressures. Given the disposable capillaries and pistons,positive displacement absolutely eliminates cross-contaminationfrom aerosols, samples or pipette.ComfortablePos-D rests in your hand while you work – no need to grip!The display faces you, so no twisting wrist or pipette to setor read volume. Natural feel, fits comfortably in your hand.Easy to loadPre-assembled, presterilized capillaries in racks.No aerosol contaminationNo air between the liquid sample and the pistonprevents formation of aerosols and protects samplesfrom instrument contamination.Pipette plunger force comparisonOrdering informationPresterilized and racked capillariesOrdering information<strong>Rainin</strong> Classic 200µlOther makes 200µl3 kg4 kg0 1 2 3 4<strong>Rainin</strong> Classic reduces plunger force by 25%.Cat. No. MT Order No. Volume Range<strong>Rainin</strong> ClassicPR-2 17008648 0.1–2 μlPR-10 17008649 0.5–10 μlPR-20 17008650 2–20 μlPR-100 17008651 10–100 μlPR-200 17008652 20–200 μlPR-1000 17008653 100–1000 μlPR-5000 17008654 500–5000 μlPR-10ML 17008655 1–10 mlPR-START 17008708 Starter Kit<strong>Rainin</strong> Classic PR-START<strong>Rainin</strong> Classic pipettes: PR-20, PR-200, PR-1000Racks of traditional tips: RT-250, RT-1000Hang-Ups (HU-M3): Set of 3Sterilized by e-beam radiationGet the security of assembled, presterilized, and rackedcapillaries and pistons for almost the same price or lessthan non-sterile capillaries.Easy to pick up and ejectAssembled and racked by a robotic process withouthuman contact, <strong>Rainin</strong> capillaries are easy to use andalso fit Gilson Microman.Prevent sample carryoverDisposable capillaries and pistons provide absoluteprotection against cross contamination.Color-coded racks and plunger buttonsFor convenience, the plunger button tops on each of thesix volume ranges of the Pos-D pipette match the accentcolor of the appropriate capillary-piston rack.Cat. No. MT Order No. Volume RangePos-D pipettesMR-10 17008575 0.5–10 μlMR-25 17008576 3–25 μlMR-50 17008577 20–50 μlMR-100 17008578 10–100 μlMR-250 17008579 50–250 μlMR-1000 17008580 100–1000 μlCapillaries and PistonsC-10 17008604 3 racks of 60 each, presterilizedC-25 17008605 3 racks of 60 each, presterilizedC-50 17008606 3 racks of 60 each, presterilizedC-100 17008607 3 racks of 60 each, presterilizedC-250 17008608 3 racks of 60 each, presterilizedC-1000 17008609 3 racks of 60 each, presterilizedwww.mt.com/rainin68 | 69


RAININSpecialty ProductsAutoRep EAdjustable electronic repeaterSpeed up long pipetting series, precisely and fatigue-free.Wide selection of easy-to-exchange syringes ensuresoptimal performance on any volume from 1μl – 50ml.Encode syringes recognized by AutoRep.Ordering InformationCat. No. MT-Order-No DescriptionAutoRep repeater pipetteAR-E1 17000723 AutoRep E electronic repeater pipette, 1 µl to 50 mlAR-M2 17000728 AutoRep M manual repeater pipette,10 µl to 5 mlAR-ADP 17000556 Charger adapter, AutoRep EAR-BA 17003233 NiMH battery pack, AutoRep EAR-RB 17004324 Charging base, AutoRep EAR-ADPAU 17000553 Adapter for charging base AUAR-EIAU 17000724 AutoRep E, 1 µl–50 ml AUAR-EIEU 17000725 AutoRep E Rep 1 µl–50 ml EUAR-EIX 17000726 AutoRep E Rep 1 µl–50 ml EXAR-EIUK 17000727 AutoRep E Rep 1 µl–50 ml UKEncode syringesENC-100 17007399 0.1 ml, 100 per pkgENC-100S 17007400 0.1 ml, 100 per pkg/ sterileENC-500 17001871 0.5 ml, 100 per pkgENC-500S 17001872 0.5 ml, 100 per pkg, sterileENC-1250 17001873 1.25 ml, 100 per pkgENC-1250S 17001874 1.25 ml, 100 per pkg, sterileENC-2500 17001877 2.5 ml, 100 per pkgENC-2500S 17001878 2.5 ml, 100 per pkg, sterileENC-5ML 17001883 5 ml, 100 per pkgENC-5MLS 17001884 5 ml, 100 per pkg, sterileENC-12ML 17001875 12.5 ml per pkg, 100ENC-12MLS 17001876 12.5 ml, 100 per pkg, sterileENC-25ML 17001879 25 ml*, 50 per pkgENC-25MLS 17001880 25 ml*, 25 per pkg, sterileENC-50ML 17001881 50 ml*, 25 per pkgENC-50MLS 17001882 50 ml*, 25 per pkg, sterileENC-SET 17001885 Encode set, non-sterile, 20 each: 0.5, 1.25, 2.5, 5, 12.5 mlENC-10ADP 17000546 Adapter for 25, 50 ml, non-sterile, 10/pkgENC-ADPS 17000547 Adapter, 25, 50 ml, sterile, individually-wrapped, 5/pkg* Includes one adapter. Sterile syringe tips are endotoxin-free, individually wrapped.AutoRep M2Manual DispenserReduces repetitive strain injuries.AutoRep E virtually eliminates all forces contributing to repetitivestrain injuries often experienced in multi-dispense pipetting.Three modes for flexibility.Dispensing: Step counter displays volume.Auto-Dispensing: Learns your pace and continuesat this same pace. No time-interval programming.Pipetting: Positive-displacement syringe.Rechargeable battery eliminates downtime.Fully charge the AutoRep E in only 2.5 hours. The no-memory,no-maintenance NiMH battery pack may be charged in the samebase while another pack is used.For complete details about AutoRep M, see www.mt.com/raininEncode syringes for AutoRep E• AutoRep E displays Encode syringe volume automatically• Ideal for viscous or high vapor pressure liquidswww.mt.com/rainin 70 | 71


RAININSpecialty ProductsPipet-X Pipet ControllerSample large volumes with confidenceSample large volumes (up to 100 ml) with our new lightweightPipet-X pipet controller. Ample flexibility for a widerange of liquid transfer and measurement options.Disp-X Bottle-Top DispenserHandle reagents safely and easilyThe built-in safety features of our new Disp-X manualbottle-top dispenser protect from accidental spills andensure smooth, trouble-free operation. Compatiblewith a wide range liquids.Superior chemical compatibilityHigh-grade inert materials used in manufacturing assurethe purity of your reagents from the first aliquot to the last.Built-in safety featuresDischarge tube and closure cap prevent accidentaldispensing or spilling of corrosive liquid.Clear and easy controlAdjustable control knob makes setting the volume easy.Flexible filling and discharging optionsDifferent filling and discharging tube diameters andshapes to suit your application workflow.One tool is all you needThe Pipet-X pipet controller excels at all serologicalpipetting applications; uses standard plastic or glassserological pipets.Flexible one-handed controlThe ergonomic grip and buttons are designed forcomfort with large or small hands.Smart rechargingPipet-X uses a rechargeable NiMH battery for up to8 hours of uninterrupted use. Operate while rechargingwith power cord.Contamination freeA built-in check valve and 0.2 micron hydrophobicmembrane filter protect the Pipet-X internal componentsfrom contamination during aspiration.Pipet-X pipet controllerCat. No. MT Order No. DescriptionPX-100 17011733 Pipet-X Pipet Controller; 0.1 - 100 mlPX-SA 17011744 Pipet-X Silicone Adapter with Check ValvePX-020 17011745 Pipet-X Spare Membrane Filter: 0.2 µm, sterilePX-NIMH 17011746 Pipet-X Nickel-Metal Hydride BatteryPX-100EU 17011743 Pipet-X Pipet Controller, EUDisp-X bottle-top dispenserCat. No. MT Order No. DescriptionDX-5 17011768 Disp-X 0.5–5 ml Bottle-Top DispenserDX-10 17011770 Disp-X 1–10 ml Bottle-Top DispenserDX-25 17011772 Disp-X 2.5–25 ml Bottle-Top DispenserDX-50 17011774 Disp-X 5–50 ml Bottle-Top DispenserDX-5EU 17011769 0.5–5 ml Bottle -Top Dispenser, EUDX-10EU 17011771 1–10 ml Bottle -Top Dispenser, EUDX-25EU 17011773 2.5–25 ml Bottle -Top Dispenser, EUDX-50EU 17011775 5–50 ml Bottle -Top Dispenser, EUDX-ADPAU 17011916 Pipet-X Pipet Controller Adapter, AUAccessoriesCat. No. MT Order No. DescriptionDX-DT10 17011747 Discharge Tubes 5 or 10 ml bent, 80 mm, pack of 2DX-DT50 17011748 Discharge Tubes 25 or 50 ml bent, 120 mm,pack of 2DX-FT250 17011749 Filling Tubes with Adapter 250 mm x 6.9 mm OD,pack of 2DX-FT390 17012004 Filling Tubes with Adapter 390 mm x 6.9 mm OD,pack of 2DX-FT335 17011750 Filling Tubes with Adapter 335 mm x 6.9 mm OD,pack of 2DDX-FV10 17011757 Filling Valve with Sealing Washer 5 or 10 mDX-FV50 17011765 Filling Valve with Sealing Washer 25 or 50 mDX-DV10 17011766 Discharge Valve with Sealing Washer 5 or 10 mlDX-DV50 17011767 Discharge Valve with Sealing Washer 15 or 50 mlwww.mt.com/rainin72 | 73


RAININSpecialty ProductsLiteTouch 1.7 ml Microcentrifuge TubesQuick and easy one-hand operationThe unique rear tab and hinge design on our innovativeLiteTouch microcentrifuge tubes makes them easier andfaster to open with just one hand. By placing the tab overthe hinge, a light downward pressure is all it takes to“pop” the secure seal and lift the cap.Compared with the prying motion required to openconventional tubes, <strong>Rainin</strong>’s new LiteTouch tubes are adramatic, ergonomic improvement that will enhance yourwork flow and speed throughput with multiple samples.Innovative, easy openingThe LiteTouch tube employs a patented rear hinge and tabmechanism to open the cap. This mechanism eliminates theneed to push up on the front of the cap, improving control,reducing fatigue and increasing throughput.Clarity, color, convenienceLiteTouch tubes are made from a durable, high-clarity homopolymer.Frosted writing surfaces on the cap and tube for labeling,and graduation marks every 0.5 ml. LiteTouch tubes areautoclavable. Available in natural, blue, black, red, green andyellow. Natural tubes are available pre-sterilized. Photo-opaqueblack tubes are suitable for light-sensitive applications.Reduced cross contaminationPressing down on the rear tab instead of prying up from thefront virtually eliminates cross-contamination of gloves,pipettes, other surfaces and the sample.Quality is assuredManufactured under Class 100,000 clean-room conditions,LiteTouch tubes are free of detectable biological contaminationsuch as RNase, DNase, DNA, ATP, pyrogens, nucleases andPCR inhibitors.Ordering InformationCat. No. MT Order No. DescriptionLTT-170-N 17011860 LiteTouch 1.7 ml microcentrifuge tube (natural) bag of 500LTT-170-N-S 17011861 LiteTouch 1.7 ml microcentrifuge tube (natural, sterile) bag of 500LTT-170-B 17011862 LiteTouch 1.7 ml microcentrifuge tube (blue) bag of 500LTT-170-G 17011863 LiteTouch 1.7 ml microcentrifuge tube (green) bag of 500LTT-170-R 17011864 LiteTouch 1.7 ml microcentrifuge tube (red) bag of 500LTT-170-Y 17011865 LiteTouch 1.7 ml microcentrifuge tube (yellow) bag of 500LTT-170-X 17012132 LiteTouch 1.7 ml microcentrifuge tube (photo-opaque black) bag of 500www.mt.com/rainin 74 | 75


RAININServicePreventive MaintenanceStop failures before they occurPreventive Maintenance is the key to keeping yourpipettes at peak performance and reducing or evenpreventing out-of-tolerance failure between calibrationintervals. Compared with other service providers,<strong>Rainin</strong> service offerings are the most comprehensiveand affordable available.PassPassFail25-35% FailTypical “As Found” Failure RatesAs a population, pipettes checkedannually without RAININ preventivemaintenance will have a 20% ormore failure rate.Nothing lasts foreverA pipette is made of a variety of mechanical parts. Like allthings mechanical, nothing lasts forever. Piston surfaces candeteriorate over time, leading to premature seal failure andpipette inaccuracy. Seals can leak after being exposed to roughpiston surfaces or to sample contamination. Shaft ends canbe worn over time, especially when high force or “banging” isapplied when mounting tips. Often, leakage is gradual andmay not be discovered until it is too late, adversely affectingthe integrity of your research.Failure Rate (%)1512963060%Seal25%Piston60% SealAnnual improvements after each<strong>Rainin</strong> CalPM service.1st 2nd 3rd 4th 5thVisit to <strong>Rainin</strong> Service CenterThis chart shows a sample reduction in out-of-tolerance pipette failuresthat occur over time when pipettes are serviced on a regular basis.10%Shaft5%Other10% ShaftFailure Rate by ComponentOver 95% of pipette failure isattributable to sealing system wear.This is predictable and preventablewith regular preventive maintenance.Sealing system wear is predictable and preventable25% Piston 5% Other95% of all pipette failure relates to sealing system wear. Undernormal use and based on our extensive experience, sealsshould be replaced at least once per year, shafts and pistonsevery 3-5 years. Failure rates can be significantly reduced ifscheduled preventive maintenance is utilized.<strong>Rainin</strong>’s preventive maintenanceprograms at a glance.Assurance-CheckPM and Verification Services Calibration PM Services Program DetailsBasic Standard Advanced Pro Pro PlusOSPM Mail-in PM PM Plus Plan A Plan B Plan Bw EMO4 4Custom4 4 4 As Found (AF) Calibration Performance Measurement4 4 4 44 4 2 volumes, 4 weighingsAs Returned (AR) Calibration Performance Measurement4 3 volumes, 10 weighings4Custom no. of volumes (up to 3) and weighings (up to 10)Pipette performance balance screening test (3 weighings at10% volume, 1 weighing at 100% volume)Preventive maintenance performed4 4 4 4 4 4 44 4 4 4 4 4 4 Thorough pipette cleaning4 4 4 4 4 4 4 Visual and pressurized leak test4 4 4 4 4 4 44 4 4 4 4 4 4 Replace worn seals, shafts1 (<strong>Rainin</strong> and Gilson pipettes)4 4 4 4 Replace pistons2 (<strong>Rainin</strong> and Gilson pipettes)4 4 4 4Thorough inspection, internal and external function testingGravimetric evaluation and/or adjustment to manufacturer orISO 8655 specificationsISO 17025 certification34 4 4 44 4 4 44 4 Individual Pipette Service Report4 4 Summary Report4 4 4 4 4 4 44 4 4 4 4 44 4 4 4 4 4 Controlled environment4 4 4 4 4 4 4 44 4 4 4 4 4 4 4 Pipette label with due date4 4 4 4 4 4 4Individual Pipette Calibration CertificateAvailable OnSite in select areas with minimum requirementsISO 17025 accredited Service Center with MT balancesReminder notice for scheduled service12 months warranty on parts and labor<strong>Rainin</strong> has been a leading pipette manufacturer and a service provider for more than 40 years. Our parent firm, METTLER TOLEDO is one of themost respected manufacturers and suppliers of high precision balance technology. Together, no company is better experienced and equipped tokeep your pipettes in perfect working condition – choose <strong>Rainin</strong> Service with METTLER TOLEDO balances!4 4 4 4 4 4 4 4 DNA-off and RNase-off decontamination service41. Seal every visit. Shaft replaced as needed. For <strong>Rainin</strong> and Gilson pipettes – other manufacturer's pipettes subject to need and parts availability.2. Pistons replaced free of charge as necessary, except when the piston shows damage from harsh or corrosive chemicals, or from misuse or abuse.In such cases there will be a piston replacement charge. Other manufacturer's pipettes subject to need and parts availability.3. Additional charge applies.4. Additional charge applies.www.mt.com/rainin 78 | 79


RAININServiceCalPM SM ServiceCalibration with Preventive MaintenanceWith four ISO-17025 accredited Service Centers in theU.S. and trained service technicians using 6 and 7-placeMETTLER TOLEDO balances, <strong>Rainin</strong> is your best choicefor pipette service. To qualify as pipette calibrationspecialists, <strong>Rainin</strong> technicians complete extensivetraining in all aspects of pipette service and operationof major manufacturers‘ pipettes.Pipettes received into <strong>Rainin</strong> Service Centers areprocessed within 48 hours in the facility.Multichannel ServiceCalibration on all channelsRAININ’s service options provide complete calibrationdata for all channels of your multichannel pipettes asif they were separate pipettes. Preventive Maintenanceis provided for all major brands.Calibration on All Channels• Accurate calibration data on all channels• No guesswork, full documentation• ISO 8655 requirement satisfied• Save time and moneyCalPM Service Plan DetailsAs Found As Returned Certificates. Purchase at the sameCat. No. Pipette Type Plan(Volume settings x number of weighings x number of channels) time as new pipettes*PA Single channel A N/A 2 x 4 CPA-CERTPB B 2 x 4 2 x 4 CPB-CERTPE B with EMO 3 x 4 3 x 10 CPE-CERTPA-M Multichannel One A N/A 2 x 4 x 1 (1 x 1 remaining channels) CPA-CERT-MOPB-M B 2 x 4 x 1 2 x 4 x 1 (1 x 1 remaining channels) CPB-CERT-MOPE-M B with EMO** 3 x 4 x 1 3 x 10 x 1 (1 x 1 remaining channels) CPE-CERT-MOMultichannel AllPA-M8 8-channel A N/A 2 x 4 x 8 M8-CERT-APA-M12 12-channel N/A 2 x 4 x 12 M12-CERT-APB-M8 8-channel B 2 x 4 x 8 2 x 4 x 8 M8-CERT-BPB-M12 12-channel 2 x 4 x 12 2 x 4 x 12 M12-CERT-BPE-M8 8-channel B with EMO 2 x 4 x 8 2 x 10 x 8 M8-CERT-EPE-M12 12-channel 2 x 4 x 12 2 x 10 x 12 M12-CERT-EPE-M8-P 8-channel 3 x 4 x 8 3 x 10 x 8 M8-CERT-EPPE-M12-P 12-channel 3 x 4 x 12 3 x 10 x 12 M12-CERT-EPEMO = Extended Measurement Option*Includes PM parts and labor **Also includes 1-2 weighings per nominal volume for “as found” and “as returned”. If incoming pipettes fail functional inspection forreasons not covered under preventive maintenance, repairs will be made for additional charge for labor and parts. ISO 17025 certificates available at additional charge.Multichannel All SMThis plan gravimetrically evaluates every channel of the multichannelpipette including complete calibration data for all channels.Preventive maintenance is provided for all major brands ofmultichannel pipettes. Multichannel All is the best choice whenyou need the highest level of confidence and reliability.Multichannel One SMThis lower-cost plan gravimetrically evaluates one channel, likea single-channel pipette. Each remaining channel is checkedwith one weighing at nominal volume. Results are stated on theCalibration Certificate.CalPM CertificationStart your pipettes out right and get all the benefits of our CalPM service, including complete documentation, at a reducedprice, by purchasing CalPM Certification at the same time as you purchase your new pipettes. Choose a service interval and<strong>Rainin</strong> will contact you when it is time for your next service. See last column above for catalog numbers for CalPM certificates.Enroll now! Call 800-543-4030, 8am-8pm ET. Return forms, free return kits & sample certificates online at www.mt.com/rainin-service-uswww.mt.com/rainin80 | 81


RAININServiceISO 17025 Accredited ServiceUnderwritten by NVLAPPipette Decontamination ServicesEliminate DNA and RNase contaminationISO 17025 documentation is available for any <strong>Rainin</strong> serviceplan, providing a statement of measurement uncertainty pervolume setting on the calibration certificate. Every <strong>Rainin</strong> servicecenter complies with all quality standards as set forth by ISOrequirement and confirmed through stringent NVLAP audits,assuring you the highest level of calibration competency.NVLAP logo and codes for the four US <strong>Rainin</strong> Service CentersDNA contamination in a PCR lab can result in DNAamplification artifacts. And as RNase degradesRNA, pipettes used in RNA work need to be freefrom RNase.These service programs are add-ons to <strong>Rainin</strong>’sCalPM and standalone PM verification plans, andwill keep your pipettes free from contaminationby DNA and RNase.ISO-17025informationISO-17025informationPipette performanceas received fromyour facilityISO-17025informationAs found pipetteperformance historyPipette performanceas returned fromRAININ Service CenterAs Returned pipetteperformance historyProcess Highlights• Work surface, tools and equipment are cleaned prior to decontaminationwith DNA-OFF and/or RNase-OFF to preventcross-contamination• Certified technicians work in protective lab clothing to preventcross-contamination• Entire external pipette body and all disassembled componentsdecontaminated*• Electronic components isolated and protected from liquids• Decontaminated parts are thoroughly cleaned and dried beforereassemblyOrdering InformationCat. No: D-CleanPipette Cleaning and Decontamination with DNA-OFF Cat. No: R-CleanPipette Cleaning and Decontamination with RNase-OFF Cat. No: DR-CleanBoth D-Clean and R-Clean.ISO-17025informationNVLAP is a federally registered certification mark of the National Institute of Standards and Technology (NIST.)* Applies to <strong>Rainin</strong> and Gilson pipettes. All other pipettes will follow manufacturer’s recommendation. All pipettes must be completely free of any radioactiveor biohazardous materials prior to service. DNA-OFF and RNase-OFF are trademarks of Takara Bio Inc.www.mt.com/rainin 82 | 83


RAININServiceMail-In PM Service SMIn <strong>Rainin</strong> Service CenterOnSite PM Service SMDone right, in your labPM Plus SM and AssuranceCheck SMCost Effective Solution for Research LabsMail-In PM Service is a new program to help maintainyour pipette performance and reliability. This convenientcost-effective program is very similar in scope toOnSite PM (next column) and is performed in one ofour service centers, rather than on-site in your lab. Aprepaid shipping label is included iwth the Mail-In kit.OnSite Service is a convenient cost-effective way tomaintain your pipette performance and reliability.<strong>Rainin</strong> Service Representatives come prepared withcomputers, bar code scanners, label makers, and specializedequipment so you get the most professionalservice possible for your valuable pipettes.Regular maintenance and inspection are essentialto keep your precision pipettes in optimal workingcondition. <strong>Rainin</strong> offers a complete range ofprofessional service options to keep your pipettesin peak performance.PlungerTip ejectorStop problems before they occur• Get assurance of pipette reliability• For <strong>Rainin</strong> ® , Gilson ® , Biohit ® and Eppendorf ® single-channelpipettes• Fast 48-hour turnaround• Prepaid shipping for five or more pipettes (see below)Mail-In PM includes• Detailed pipette inspection• Pressure leak-test• Pipette cleaning including piston maintenance• Minor repairs• New seal every visit for <strong>Rainin</strong> and Gilson pipettes• New shaft first visit, then every 3 years for <strong>Rainin</strong> and Gilsonpipettes• Service reports, dated stickersOrdering InformationCat. No. DSPMTo request a free return kit or to arrange prepaid shipping for fiveor more pipettes, please call your nearest <strong>Rainin</strong> Service Center at800 543 4030.OnSite PMReplaces critical liquid-end parts to prevent leakage betweenscheduled visits, for high assurance of pipette reliability.Scheduled PMOnSite PM offers scheduled preventive maintenance. Preventivemaintenance helps prevent leakage before it occurs.OnSite Documentation for GLP ProgramsThanks to our complete computerized system, you will receiveimmediate hard-copy quality reports and pipette labels on the dayof your service. This documentation helps satisfy GLP guidelines.• 12-Point inspection• Pressure leak test• Thorough pipette cleaning• Minor repair• Replace missing, broken and worn parts• Service reports, dated stickers• Scheduled PM• Free seal and shaftOrdering InformationCat. No. OSPMPM Plus<strong>Rainin</strong>’s PM Plus is a cost effective pipette service solutionappropriate for unregulated labs. PM Plus includes completepreventive maintenance of your pipettes followed by averification check of the pipette's performance using precision<strong>Mettler</strong> <strong>Toledo</strong> balances. Three measurements are madeat the 10% volume setting and accuracy and precision areverified, then one measurement is made at 100% volume toverify accuracy at the top end.Ordering InformationCat. No. PMPAssuranceCheck<strong>Rainin</strong>’s AssuranceCheck provides a basic gravimetric testof a pipette's performance and is a useful tool for checkingperformance of your pipettes between major services orpreventive maintenance cycles. This plan is generally sufficientfor research labs not in need of documenting the statisticalsignificance of full calibration measurements.Use AssuranceCheck to identify out-of-tolerance pipettesbefore your next regularly scheduled service.Ordering InformationCat. No. ACMicrometerShaft couplingPistonAssembly:PistonSpringsThe free return kit includes a pre-paid shipping return label andpacking material. For more information and to get a return kit go to:www.mt.com/rainin-service-usBoth programs offer• Fast, convenient and cost effective service• Available for all major brands and models of pipettes• Maintain peak performance at all times for best results• Prevent high costs associated with out-of-tolerance failures• Free two-way shipping and 48-hour in house turnaround timeSeals & O-ringTip ejectorShaftNote: OnSite Service is available in select areas, minimum charges may apply.Warranty: One year, parts and labor.Get peace of mind, enroll today! Call 800 543 4030.For return forms, free pipette service return kits and quality certificates, go to: www.mt.com/rainin-service-uswww.mt.com/rainin 84 | 85


RAININTechnical DataPipette Accuracy and PrecisionPipette SpecificationsAccurate but not Precise Precise but not Accurate Accurate and PreciseAccuracy (Mean Error)Accuracy, or mean error, is the amount by which the meanvalue of a large set of replicate liquid measurements deviatesfrom the nominal value of the volume shown on the digitaldisplay of the pipette. The specification given for each pipetteis the maximum allowable value for mean error. Mean errormay be expressed as shown in the equations below.Precision (Repeatability)Precision is the numerical assessment of the random dispersionof a number of replicate measurements, expressed as standarddeviation or coefficient of variation. In this publication, precisionrefers to a “within-run” deviuation, i.e. the standard deviation fora series of measurements at the same volume setting, performedat one location in a contiguous time period, with a new disposabletip for each pipetting cycle. Standard deviation and coefficient ofvariation may be expressed as shown in the equations below.Pipet-Lite XLS and <strong>Rainin</strong> ClassicVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)2 µl 0.2 0.002 12 0.024 6 0.0121.0 2.7 0.027 1.3 0.0132.0 1.5 0.030 0.7 0.01410 µl 1 0.02 2.5 0.025 1.2 0.0125 1.5 0.075 0.6 0.0310 1 0.1 0.4 0.0420 µl 2 0.02 7.5 0.15 2 0.0410 1.5 0.15 0.5 0.0520 1 0.2 0.3 0.06100 µl 10 0.2 3.5 0.35 1 0.150 0.8 0.4 0.24 0.12100 0.8 0.8 0.15 0.15200 µl 20 0.2 2.5 0.5 1 0.2100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3300 ul 30 0.5 2.5 0.75 1.0 0.3150 0.8 1.2 0.25 0.375300 0.8 2.4 0.15 0.451000 µl 100 2 3 3 0.6 0.6500 0.8 4 0.2 11000 0.8 8 0.15 1.52000 µl 200 2 3 6 0.6 1.21000 0.8 8 0.2 22000 0.8 16 0.12 2.45000 µl 500 5 2.4 12 0.6 32500 0.6 15 0.2 55000 0.6 30 0.16 810 ml 1 ml 20 5 50 0.6 65 ml 1 50 0.2 1010 ml 0.6 60 0.16 1620 ml 2 ml 20 5 100 0.6 1210 ml 1 100 0.2 2020 ml 0.6 120 0.16 32Multichannel Manual and Electronic PipettesVolume Increment Increment Accuracy PrecisionModel µl µl (man) µl (elec) % µl (±) % µl (≤)10 µl 1 0.02 0.01 2.5 0.025 1.2 0.0125 1.5 0.075 0.6 0.0310 1.0 0.1 0.4 0.0420 µl 2 0.02 0.02 7.5 0.15 2.0 0.0410 1.5 0.15 0.5 0.0520 1.0 0.2 0.3 0.0650 µl 5 0.05 0.05 3.5 0.18 1.5 0.07525 1.2 0.3 0.4 0.150 0.8 0.4 0.2 0.1200 µl 20 0.2 0.2 2.5 0.5 1.0 0.2100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3300 µl 30 0.5 0.2 2.5 0.75 1.0 0.3150 0.8 1.2 0.25 0.375300 0.8 2.4 0.15 0.451200 µl 100 2 1 3.6 3.6 0.6 0.6600 0.8 4.8 0.2 1.21200 0.8 9.6 0.15 1.8E4XLSVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)10 µl 1 0.01 2.5 0.025 1.2 0.0125 1.5 0.075 0.6 0.0310 1.0 0.1 0.4 0.0420 µl 2 0.02 7.5 0.15 2 0.0410 1.5 0.15 0.5 0.0520 1.0 0.2 0.3 0.06100 µl 10 0.1 3.5 0.35 1 0.150 0.8 0.4 0.24 0.12100 0.8 0.8 0.15 0.15200 µl 20 0.2 2.5 0.5 1 0.2100 0.8 0.8 0.25 0.25200 0.8 1.6 0.15 0.3300 ul 30 0.2 2.5 0.75 1 0.3150 0.8 1.2 0.25 0.375300 0.8 2.4 0.15 0.451000 µl 100 1 3 3 0.6 0.6500 0.8 4 0.2 11000 0.8 8 0.15 1.52000 µl 200 2 3 6 0.6 1.21000 0.8 8 0.2 22000 0.8 16 0.12 2.45000 µl 500 5 2.4 12 0.6 32500 0.6 15 0.2 55000 0.6 30 0.16 810 ml 1 ml 10 5 50 0.6 65 ml 1 50 0.2 1010 ml 0.6 60 0.16 1620 ml 2 ml 20 5 100 0.6 1210 ml 1 100 0.2 2020 ml 0.6 120 0.16 32Pos-DVolume Increment Accuracy PrecisionModel µl µl % µl (±) % µl (≤)10 μL 1 0.02 9.0 0.09 3.0 0.035 2.0 0.10 0.6 0.0310 1.5 0.15 0.6 0.0625 μL 3 0.02 8.3 0.25 2.7 0.0810 2.7 0.27 0.8 0.0825 1.2 0.30 0.4 0.1050 μL 20 0.02 1.7 0.34 1.0 0.2050 1.4 0.70 0.6 0.30100 μL 10 0.2 5.0 0.50 2.0 0.2050 1.5 0.75 0.6 0.30100 1.0 1.00 0.4 0.40250 μL 50 0.2 3.0 1.50 0.6 0.30100 1.7 1.70 0.3 0.30250 1.0 2.50 0.2 0.501000 μL 100 2 3.0 3.00 1.6 1.60500 1.0 5.00 0.5 2.501000 0.8 8.00 0.4 4.00www.mt.com/rainin 86 | 87


RAININGeneral Information<strong>Rainin</strong> in North AmericaCustomer ServicePhone: 800 472 4646E-mail: pipets@rainin.comTechnical ServicePhone: 800 543 4030E-mail: tech.support@rainin.comPipette ServicePhone: 800 662 7027E-mail: service@rainin.comService CentersCalifornia7500 Edgewater Drive, Oakland, CA 946215955 Mira Mesa Blvd., Suite B, San Diego, CA 92121Massachusetts900 Middlesex Turnpike, Bldg 8, BIllerica, MA 01821Pennsylvania200 Rittenhouse Circle East, Unit 2, Bristol, PA 19007Canada2915 Argentia Road, Unit # 5,Mississauga, Ontario L5N 8G6Trademarks<strong>Rainin</strong>, Pipet-Lite, XLS, LTS, LiteTouch, Liquidator, EDP, Pipetting 360°, BioClean,GPP, Good Pipetting Practice, True Manual, Pos-D, <strong>Rainin</strong> Classic, Magnetic Assist,SpaceSaver, Green-Pak, FinePoint, Clean-Pak, Gel-Well, ShaftGard, StableRak,StableStak, Hang-Ups, AutoRep and Encode are trademarks of <strong>Rainin</strong> Instrument,LLC. Calibration PM, OnSite PM, Mail-in PM, D-Clean, R-Clean, DR-Clean, AssuranceCheck,PM Plus, Multichannel One, Multichannel All, and Pipetting Solutionsare service marks of <strong>Rainin</strong> Instrument, LLC. Pipetman, Microman, Distriman,Gilson, Eppendorf, LabSystems and Brand are trademarks of their respective owners.To order(In other countries order through METTLER TOLEDO)By Phone: 800-4-RAININ (800 472 4646)Order Hours: 8 am - 8 PM ESTOrders received by 7 pm are typicallyshipped same day.By Fax: 1 510 564 1617By Mail: 7500 Edgewater Drive, Box 2160Oakland, CA 94621-0061Online (US only): www.rainin.com• Secure Ordering 24/7 with your <strong>Rainin</strong> Account #• Use your PO# or credit care for online ordering• Get the latest information and quotes• Obtain product, service, and technical informationTerms• Prices are FOB Oakland, CA• Freight charges are prepaid and added to invoice• Net 30 days (for established accounts)• <strong>Rainin</strong> Standard Terms and Conditions of Saleapply to all ordersShippingItems shipped in the US via UPS Ground, unless otherwiseinstructed. Typical delivery times are 3-5 business days.ReturnsReturns are accepted with prior authorization only.Contact Customer Service for instructions.Liability and Warranty<strong>Rainin</strong> sells the products in this catalog for laboratory useonly. They are not intended for household use or medicalpurposes. <strong>Rainin</strong> products are warranted free from defectsin materials and workmanship for one year from date ofpurchase.FSC certified printer and cover stock (30% PCW).Inside pages printed on 55% recycled papercontaining 30% PCW.


<strong>Rainin</strong> USA7500 Edgewater Drive, Box 2160Oakland, California, USA 94621-0060Main: tel. 510 564 1600fax. 510 564 1617Ordering: tel. 800 472 4646 (toll-free)email: pipets@rainin.comwww.mt.com/raininFor more informationSubject to technical changes© 11/2013 <strong>Mettler</strong>-<strong>Toledo</strong>Printed in USAMarketing, <strong>Rainin</strong> Instrument, LLCISO 9001 quality certificationInternet: http://www.mt.com/raininWorldwide service

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!