HubbellSafetyInstall one switchat the controllerlocation and anotherat the disconnectlocation. Hubbell’sdisconnects are ratedto withstand 10,000-amp high fault shortcircuits for maximumsafety. Because everyCircuit-Lock ® controlleris a disconnect, moredisconnect safetylocations can be addedacross the factory floor.HubbellFlexibilityElectrical designs musttake into account thedisconnect locationto ensure line of sightplacement. Line ofsight can now bee<strong>as</strong>ily achieved at theequipment or on the wallby installing a HubbellCircuit-Lock controller/disconnect. Safe,strategic disconnectplacement is moreflexible than ever withsmaller-sized switchesand a variety of NEMAtype enclosures.HubbellComplianceNEC conformance isthe requirementfor industrial motorapplications <strong>as</strong>inspected by OSHA.Because oneCircuit-Lock motorcontroller meets boththe disconnect andcontroller specifications,confusion is minimizedabout where and howeach switch is used.The switch is always adisconnect, so it’sHubbellProductivityNo longer is the entirecircuit powered down torepair just one piece ofequipment. By addingthe disconnect rating tothe Circuit-Lock motorcontroller, Hubbell letsyou safely terminatepower at any point inthe circuit. Maintenancecan now be doneon a motor withoutthe inconvenience ofshutting down the entireline and sacrificingproductivity.always compliant.Each Controller that Hubbell Builds is also a Disconnect<strong>Controllers</strong>/DisconnectsDisconnect<strong>Motor</strong> Loads2www. hubbell-wiring.com


AC <strong>Manual</strong> Toggle <strong>Controllers</strong>/Disconnects30, 40, 50, 60 and 85A 600V AC600V AC <strong>Manual</strong> <strong>Motor</strong> <strong>Controllers</strong>Order InformationFor use in any industrial environment. Ideal component switch for motor control and <strong>as</strong> a disconnect. Toggle controllerscan be built into equipment and enclosures for either box or panel-mount installation.HP RatingToggleCatalogAmp Poles Type Wire 120V AC 240V AC 480V AC 600V AC Numbers30 2 Standard — 2 5 10 15 HBL7832D30 2 Short — 2 5 10 15 HBL7832DS30 3 Standard — 3 7.5 15 20 HBL7810D30 3 Short — 3 7.5 15 20 HBL7810DS40 2 Standard — 2 5 10 15 HBL7842D40 3 Standard — 3 7.5 15 20 HBL7843D50 2 Standard — 2 5 10 15 HBL7852D50 3 Standard — 3 7.5 15 25 HBL7853D60 2 Standard — — 10 15 20 HBL7862D60 3 Standard — — 10 25 30 HBL7863D60 2 Standard Front — 10 15 20 HBL7862FWD60 3 Standard Front — 10 25 30 HBL7863FWD85 2 Standard — — 10 15 20 HBL7882D85 3 Standard — — 10 25 40 HBL7883DFinger Guards (red) for use with 30, 40 and 50A switches (set).HBLFG30HBL7810DHBL7863DHBL7853DHBLFG30SpecificationsDimensional Drawings Electrical PerformanceDielectric Voltage 2,200V AC minimum for 1 minuteElectrical Life 6,000 Cycles at rated switch loadMax. Working Voltage 600V AC RMSSwitches 10,000 RMSShort Circuit 30A & 40A 60A max. J fusesWithstand Rating 50A 50A max. J fuses<strong>as</strong> <strong>Motor</strong> Disconnect 60A & 85A 80A max. J fusesShort CircuitWithstand Rating All Switches 125A max. RK5 fuses<strong>as</strong> <strong>Motor</strong> Controller MechanicalMechanical Life10,000 minimum cyclesAmps AWG Min. AWG Max.Terminal 30 #14 #10Accommodations 40 & 50 #14 # 860 & 85 #14 # 4Terminal Torque 30 - 50 20 inch pounds60 - 85 25 inch pounds Environmental3.28"(83.3)30, 40 and 50 Amp Toggles3.78"(96.0)2.25"(57.2)ONFront3.56"(90.4)ON2.38"(60.4)3.28"(83.3)60 and 85 Amp Toggles2.38"(60.4)3.78"(96.0)Side1.53"(38.9)1.92"(48.8)2.43"(62.0)2.83"(71.9)Flammability UL94HB/VOOperating Temp. Max. continuous 30, 40 & 60A 60 °CMax. continuous 50 & 85A 75 °CMin. continuous w/out impact -40 °C ListingsFrontSideUL 508 Industrial Control Equipment File #E70402CSA-C22.2 No.14 Industrial Control Equipment File # LR-461864www. hubbell-wiring.com


NEMA 3/3R Disconnect Switches"<strong>Suitable</strong> <strong>as</strong> <strong>Motor</strong> Disconnects"SHARED FEATURESRain tight enclosures.Designed for surface mounting.Heavy duty flip lid.3-sided protection.Die c<strong>as</strong>t aluminum enclosure.Gray zinc powder coat finish.Three 1/2" NPT threaded outlets.On top, bottom and back of enclosure.HBL13R13DHBL13R23DVALOX ® enclosure.Chemical and impact resistant.External activationlever switch.Installer determinedwire entry.No predrilled openingsor knockouts. <strong>CIRCUIT</strong>-<strong>LOCK®</strong> NEMA type 3/3Renclosures are "<strong>Suitable</strong> <strong>as</strong> Disconnect"when used with the 30 amp controller/disconnect. Compact size allows for strategicplacement.<strong>CIRCUIT</strong>-LOCK ® NEMA 3/3R Enclosures with SwitchOrder InformationIdeal for use on outdoor equipment.Enclosure HP Rating CatalogAmp Poles Material 120V AC 240V AC 480V AC 600V AC Numbers30 2 Thermopl<strong>as</strong>tic 2 5 10 15 HBL13R22D*30 3 Thermopl<strong>as</strong>tic 3 7.5 15 20 HBL13R23D*30 2 Aluminum 2 5 10 15 HBL13R12D †30 3 Aluminum 3 7.5 15 20 HBL13R13D †Note: For switch specifications refer to page 4.* Drill weephole to alter from NEMA 3 to NEMA 3R.† Equipped with HBLFG30 sidewall insulation barriers.Dimensional DrawingsHBL13R22D and HBL13R23D2.99"(75.9)HBL13R12D and HBL13R13D2.93"(74.4)1.84"(46.7)2.25"(57.2)HBL13R23D3.94"(100.1)HBL13R13D4.76"(120.9)5.42"(137.7)ONOFF0.30" (7.6)PADLOCK HOLE3.24"(82.3)4.51"(114.6)2.22"(56.4)2.99"(75.9)4.55"(115.6)0.34" (8.6)PADLOCK HOLEFront Side Back Front InsideCoverVALOX ® is a registered trademark of General Electric Company (GE). 6www. hubbell-wiring.com


NEMA 3R Disconnect Switches"<strong>Suitable</strong> <strong>as</strong> <strong>Motor</strong> Disconnects"SHARED FEATURESAll aluminum cover and b<strong>as</strong>e. B<strong>as</strong>e is pre-drilled for rear surface mounting.Rain tight drip shield top. Rolled seamless sides.Wiring conduit knockouts. 1/2" NPT K.O. for 30A. 3/4" -1" NPT K.O. for 60A. Top, bottom or back wire entry points. <strong>CIRCUIT</strong>-LOCK ® NEMA Type 3Renclosures are "<strong>Suitable</strong> <strong>as</strong> Disconnect"when used with the 30 or 60 ampcontroller/disconnect. Front activated lever allows mounting intight spaces.<strong>CIRCUIT</strong>-LOCK ® NEMA 3R Enclosures with SwitchOrder InformationIdeal for use in outdoor environments.HP RatingHBL16R93DHBL13R89DAmp Poles 120V AC 240V AC 480V AC 600V AC Catalog Numbers30 2 2 5 10 15 HBL13R92D30 3 3 7.5 15 20 HBL13R89D60 2 — 10 15 20 HBL16R92D60 3 — 10 25 30 HBL16R93DNote: For switch specifications refer to pages 2 and 3.HBL13R89D<strong>CIRCUIT</strong>-LOCK ® NEMA 3R Enclosures without SwitchOrder InformationFor use with switches shown on pages 3 and 4.DescriptionCatalog NumbersFor use with 30A switch.HBL13R90For use with 60A switch.HBL16R90Dimensional DrawingsHBL13R90, HBL13R89D and HBL13R92DHBL16R90, HBL16R92D and HBL16R93DHBL16R93D4.40" (111.8)2 - 3/4"KNOCKOUTS1.06" (26.9)1.99"(50.5)Bottom3.30"(83.3)2.75"(69.9)5.52"(140.2)4.40"(111.8)0.31" (7.9)PADLOCK HOLE3.30"(83.8) 2.75"(69.9)2.00"(50.8)Bottom2 - 3/4" x 1"KNOCKOUTS1.52" (38.6)10.11"(256.8)0.31" (7.9)PADLOCK HOLEwww. hubbell-wiring.com4.28"(108.7)Front74.28" (108.7)Front


NEMA 4X Disconnect Switches"<strong>Suitable</strong> <strong>as</strong> <strong>Motor</strong> Disconnects"SHARED FEATURESUndrilled c<strong>as</strong>e. Allows custom placement ofwire entry.Hinged cover withremovable continuous pin.304 stainless steel enclosure.Chemical and corrosion resistant.VALOX ® handle and collar.Chemical and impact resistant.Poured in closed cellneoprene g<strong>as</strong>ket.Interlocking shaftand handle.Prevents cover removalwhen switch is on.HBL13S33DUp to 2 optionalauxiliary contacts.For PLCs and external indicators.Dimensional DrawingsHBL13S33D <strong>CIRCUIT</strong>-LOCK ® NEMA Type 4X enclosures are"<strong>Suitable</strong> <strong>as</strong> Disconnect" when used with the30 or 60 amp controller/disconnect. High impact, chemical and corrosion resistant. Neutral and ground bus included for wiringe<strong>as</strong>e (60A product). Up to two optional auxiliary contacts for PLC'sand external indicators.<strong>CIRCUIT</strong>-LOCK ® NEMA 4X Enclosures with Switch and AccessoriesOrder InformationIdeal for use in environments where w<strong>as</strong>hdown is necessary, i.e. food processing, laboratories, etc.HP RatingAmp Poles 120V AC 240V AC 480V AC 600V AC Catalog Numbers30 3 3 7.5 15 20 HBL13S33D60 3 — 10 25 30 HBL16S63DFinger Guard option for 30A switchNO/NC auxiliary contact, 10A 120/250 V ACfor 30 and 60 Amp switchesNote: For switch specifications refer to page 4.6.96"(176.8)4.00"(101.6)6.10"(154.9)4.25"(108.0)HBL16S63DHBLFG30HBLAUX6.95"(176.5)HBL13S33D6.10"(154.9)HBL16S63D7.44"(189.0)6.00"6.75" (152.4)(171.5)8.75"(222.3)8.00"(203.2)9.44"(239.8)FrontSide4.00"(101.6)Front4.25"(108.0)SideVALOX ® is a registered trademark of General Electric Company (GE).8www. hubbell-wiring.com


NEMA 4X Disconnect Switches"<strong>Suitable</strong> <strong>as</strong> <strong>Motor</strong> Disconnects"SHARED FEATURESVALOX ® enclosure. For impact and chemicalresistance.Identified drill locations. Enables custom placement ofwire entry.Up to two optional auxiliarycontacts. For PLCs and external indicators.Ample wiring room for driploops.Adjustable external mountingfeet.HBLDS3Internal frame bonds all grounds.For use with pl<strong>as</strong>tic or metallic conduit.Front activated pistol handle grip.Minimizes side space clearance.Interlocking shaft and handle.Prevents cover removal in "ON" position.Safety interlocked fuse access door.Quick, e<strong>as</strong>y access to fuses.Compact fused disconnect switch.Accepts Cl<strong>as</strong>s "J" fuses.Safety features.Switch can only be turned "ON" with cover closed.Fuses can only be accessed with switch in the off position.Side activated highly visible red handle.FDS30 Safely Terminate Power at any Point in theCircuit. Flexible Disconnect Placement.www. hubbell-wiring.com9VALOX ® is a registered trademark of General Electric Company (GE).


NEMA 4X Disconnect Switches"<strong>Suitable</strong> <strong>as</strong> <strong>Motor</strong> Disconnects"NEMA 4X Switched Enclosure, UnfusedOrder InformationUsed primarily in heavy w<strong>as</strong>h-down and corrosive environments.HP RatingCatalogDescription120V AC 240V AC 480V AC 600V AC Numbers30A Disconnect switch 1 7.5 15 15 HBLDS330A Disconnect switch w/aux. contact 1 7.5 15 15 HBLDS3AC60A Disconnect Switch 7.5 30 50 50 HBLDS660A Disconnect switch w/aux. contact 7.5 30 50 50 HBLDS6AC100A Disconnect Switch 7.5 30 50 50 HBLDS10100A Disconnect switch w/aux. contact 7.5 30 50 50 HBLDS10ACAux. contact, break after break — — — — HBLAC1Aux. contact, break before break — — — — HBLAC2Ground block (30A switch) — — — — HBL30RGBGround block (60A and 100A switch) — — — — HBL60100RGBNeutral block (30A switch) — — — — HBL30RNBNeutral block (60A switch) — — — — HBL60RNBNeutral block (100A switch) — — — — HBL100RNBReplacement 30A switch — — — — HBLDS3RSReplacement 60A and 100A switch — — — — HBLDS60100RSNEMA 4X Switched Enclosure, Fused DisconnectOrder InformationUsed primarily in heavy w<strong>as</strong>h-down and corrosive environments.HP RatingCatalogDescription120V AC 240V AC 480V AC 600V AC Numbers30A Disconnect switch 2 7.5 15 20 FDS3060A Disconnect switch 3 15 30 40 FDS60Aux. contact, norm. open, A600 pilot duty — — — — ACFSNOAux. contact, norm. closed, A600 pilot duty — — — — ACFSNCSpecifications Electrical PerformanceDielectric Voltage 3,000V AC minimumElectrical Life 6,000 Cycles at rated switch parametersMax Working Voltage 600V AC RMSShort Circuit Use on a circuit capable of delivering notWithstand Rating more than 10,000 symmetrical amperes<strong>as</strong> <strong>Motor</strong> Disconnect (for HBL series 600V AC max) (for FDSand ACFSN series - at a voltage ratingwhen protected by Cl<strong>as</strong>s “J” fuses) MechanicalMechanical Life 10,000 minimum cyclesAmps AWG Min. AWG Max.Terminal 30 #14 #10Accommodations 60A #14 # 4100ATerminal Torque 30A 20 inch pounds60A 25 inch pounds100A 25 inch poundsImpact Resistance UL746C EnvironmentalFlammability UL94-5VA and V0 Cl<strong>as</strong>sificationOperating Temp. Max. continuous 75 °CMin. continuous -40 °C ListingsUL 508 Industrial Control Equipment File #E70402CSA-C22.2 No.14 Industrial Control EquipmentFile # LR-4618610Dimensional DrawingsFusedUnfusedA B C.87"(22.1)OFFON15.03"(381.8)DEF7.27"(184.7)8.43"(214.1)G11.46"(291.6)HBLDS3HBLAC1FDS3030A 60A/100AKey inch (mm) inch (mm)A 6.00 152 7.75 197B 5.12 130 6.87 175C 4.12 105 4.75 121D 6.62 168 8.00 203E 7.62 194 9.95 253F 8.50 216 11.00 279G 4.12 105 5.94 151www. hubbell-wiring.com