Probes for Coordinate Measuring Machines - Mitutoyo America ...

mitutoyo.com

Probes for Coordinate Measuring Machines - Mitutoyo America ...

SP25M45.55mm62.5mmTM25-2074.05mmSM25-1111.65mmSM25-2195.4mmSM25-32mmø25mmSP25Mprobe bodyTM25-20ø13.25mmTP20module16.95mmStylus that can be attached:20 to 50mm longStylus that can be attached: 26.25mm20 to 75mm long(Overall stylus length between 50 to 105mm.)SH25-133.85mmSH25-2Stylus that can be attached:20 to 100mm long(Overall stylus length between 120 to 200mm.Fixed toSH25-3.48.05mmSH25-3ø4mmFixed toSH25-3.ConfigurationDescriptionSP25M full combination kitSP25M scanning kit #1SP25M scanning kit #2SP25M scanning kit #3Scanning module SM25-1 kitScanning module SM25-2 kitScanning moduleStylus holder SH25-1Stylus holder SH25-2Stylus holder SH25-3TM25-20TTP module adapter kit #1TTP module adapter kit TM25-20Part No.06ABS96906ABS97006ABS97106ABS97206ABS45206ABS45306ABS45406ABS45506ABS45606ABS45706ABS47506ABS473RemarkA complete set of SP25M, SM25-1/2/3, SH25-1/2/3,and TM25-20A complete set of SP25M, SM25-1, and SH25-1A complete set of SP25M, SM25-2, and SH25-2A complete set of SP25M, SM25-3, and SH25-3A complete set of SM25-1 and SH25-1A complete set of SM25-2 and SH25-2A complete set of SM25-3 and SH25-3A set of TP20 standard force module and TM25-20* TTP module (TM25-20, TP20 module) will be supported for MCOSMOS V2.4 or later releases.* SP25M internally uses the high-power LED light source. Exercise caution whenhanding, in accordance with the Operation Manual.* Can be mounted on the MRS rack.7


QVPThe QVP probe performs form measurement by image processing micro geometry thatcannot be measured by a contact type probe, or elastic bodies that are easily deformed byslight measuring forces.Although the method of microscopic measurement with the centering microscopemounted on the coordinate measuring machine has been used since coordinate measuringmachines came into use in the industry, they have an inherent disadvantage in that theoperation of identifying positions is dependent on the operator’s eye, resulting in possiblemeasurement errors. Even with a CNC coordinate measuring machine manual measurementmust be performed sometimes, such as with an installed centering microscope. TheQVP probe is an vision probe dedicated for coordinate measuring machines and was developedbased on Mitutoyo’s state-of-the-art technology, in order to enable full automationof image measurement with a CNC coordinate measuring machine. This technology wasoriginally developed for Mitutoyo vision measuring machines.The QVP-captured image will have various automatic edge detections performed by thededicated software, Visionpak, and then various calculation processes (calculation of dimensionsand geometrical deviations) will be performed by the general-purpose measurementprogram, Geopak.Since the QVP is equipped with the standard co-axial light running through the lens systemas well as white-light LED ring illumination, which is bright and has a long service life, noauxiliary illumination is required. The light volume can be set to between 0 and 100% at1% increments.The QVP can also be mounted onto an automatic probe changer, allowing full-automaticmeasurement including both the contact and non-contact types in combination with thecontact-type probes.QVP main unitObjectiveQVP I/F BOXCCD sizeOptical tube magnificationIlluminating Co-axialfunction RingMassOptical magnificationObservation range (mm)Working distance (mm)MagnificationNumerical Aperture (N.A.)Depth of focus ( m)MassSupply voltageFrequencyPower capacityMass0.5X9.6X12.8591XOptional0.0330670g1/2 inch (B/W)0.5XWhite light LED source (built-in): Power dissipation 5W or lessWhite light LED source: Power dissipation 10W or lessAutomatic-joint type: 310g, shank type: 385g1.5X3.2X4.372.33XStandard0.075647gAC100 to 240V50/60Hz45W3800g2.5X1.9X2.659.55XOptional0.112359g5X1X1.34410XOptional0.18875g10


QVPø70ø706626 40Objective ML1X (375-036)Objective ML5X (375-034)Objective ML10X (375-035)50ø256626 40ø13.9911332182.7211.7Calibration gage(02AQC310)- Gage for sharing thecoordinates between the QVPand contact-type probeW.D.= 72.337.7QVP-A(Automatic-joint type)QVP-S(Shank type)Calibration chart(958448)- Gage for calibratinga single QVP unitUnit : mmData processing unitDedicated data processing software VISIONPAKVISIONPAK operates under the Microsoft Windows operating systemand is a general-purpose measurement program for coordinatemeasuring machines. It displays the image window when it detects aworkpiece edge. After detecting an edge, it undertakes variouscalculations with the regular general-purpose measurement programs.Wide variety of image processing functionsWith the powerful image processing functions (tools) it can detectvarious forms of edges at high speed. It can measure in the heightdirection by means of its auto-focus function, and save the capturedimage as the image data (bitmap format) as well.Outlier removal functionIn ordinary micro-form measurement it is often difficult to remove burrsand dusts from the objective workpiece, resulting in an inevitablemeasurement error. In contrast, VISIONPAK can recognize, for example,the obstruction as an "outlier" and bypass it during measurement.ocessing ToolSimple toolManual toolUsed for detecting a single pointon the edge pointed to by thearrow.Box toolUsed for detecting an optionalposition pointed to (clicked on)by the mouse.Centroid toolUsed for multiple-point linemeasurement of an edge caughtin the boxCircle toolUsed for detecting the center ofgravity of an optional form.Edge self-tracing toolUsed for multiple-point measurementof a circle for the objective circularedge. As with the box tool, it cancollect data that is free from the effectof burrs and dust.By simply specifying the startpoint and measurement interval,the objective edge can bedetected while automaticallytracing an unknown geometry.11


CF20Centering Microscope for CoordinateMeasuring MachinesThe CF20 is a centering microscope that enables measurement of small holes and elasticbodies which are difficult for a touch trigger probe to measure. With the CF20 the coordinatemeasuring machine can be used as a large microscope.To cope with the size and form of a workpiece to be observed and measured, lenses ofvarious magnifications and reticles for form comparison are provided.The dedicated CCD camera can be mounted on the back of the CF20 main unit. Videosignals from the camera can be displayed as an image on the external monitor. This is agreat aid in relieving eye stress, especially if several hours of work must be done.ø14mmEyepieceMonocular unitObjective(optional)CF20 main unit211mm30˚117mm 50mmIllumination unit51mm22.5mmCF20 monocular set (375-201) CF20 binocular set (375-202) CF20 protractor eyepiece set CF20 double image setCF20 disc plate set (375-205)(375-203)(375-204)Shank (ø14mm)Disc-plate eyepiece unitBinocular unitProtractor eyepiece unitDouble-image eyepiece unitMonocular unitShank (ø14mm)Shank (ø14mm)Shank (ø14mm)Shank (ø14mm)Main unitMain unitMain unitMain unitMain unitSpecificationsDescriptionCF20 monocularset (375-201)CF20 binocularset (375-202)CF20 protractoreyepiece set(375-203)CF20 doubleimage set(375-204)CF20 disc plateset (375-205)SpecificationAccessoryCF10X eyepiece, field number 22Cross hair and concentric circle reticle1. Illumination unit (375-071)CF10X eyepiece, field number 222. Spare lamp (162151)Cross hair and concentric circle reticle (right)3. Lens capPupil distance adjustment: 51 - 76mmCF10X eyepiece, field number 214. ToolsMeasurement range: 360˚, Angle index: 1˚5. Power cableMinimum reading: 5' (vernier scale)6. Operation ManualCF10X eyepiece, field number 227. Storage boxCF10X eyepiece, field number 22ISO metric/unify screwsCross hair and concentric circle reticle/dotted line cross scale, ML 3X objectiveIllumination unit (375-071)Powersupply boxLamphouse12


CF20Centering Microscope for Coordinate Measuring MachinesCF 1X CF 2X CF 3XML 3XUnit: mm536.3 73.7(working distance)110(parfocal distance)0.20.21101ø30ø26ø25ø30ø22ø25ø30ø25ø30ø251218 92(working distance)110(parfocal distance)532.2 77.8(working distance)110(parfocal distance)537.5 72.5(working distance)110(parfocal distance)ML 5XML 10XCF zoom 1X - 5Xø30ø17ø25ø28ø30ø21.2ø25ø28ø34ø21.5ø25ø37.210.550.5 59.5(working distance)110(parfocal distance)866 44(working distance)110(parfocal distance)11.560 50(working distance)110(parfocal distance)Order No.375-031375-032375-033375-037375-034375-035375-038DescriptionCF 1XCF 2XCF 3XML 3XML 5XML 10XCF zoom1X - 5X1X3X5XNumerical Working distanceAperture (N.A.) W.D. (mm)0.030.060.070.070.110.180.040.10.173.79277.872.559.544.050ResolutionR ( m)9.24.63.93.92.51.56.92.752.75Depth of focus of singleobjective lens ±D.F. ( m)3067656562381712727Values for resolution and depth of focus of a single objective lens are calculated based on the reference wavelength ( =0.55 m).The real field of view (mm) can be obtained from Field number/Objective magnification.Fiber optic circular illumination unit(176-366)Twin-fiber optic illumination unit(176-344)Mass(g)4535354580100200Unit: mmø18(cross hair andconcentric circle)(90º/60º dash-dot line)No. 375-021 No. 375-022 No. 375-023 No. 375-02460º10(grid)der No. 320-053]5. C-mount adapter (C)1. 1/2-inch, 410,000-pixelcolor cameraMonitor cable (supplied withthe color monitor of 3,below)4. Camera cable,length: 3m6. OperationManual3. Color monitor,2. Controller- Vertical reference line: Move, lock15-inches(2 for each vertical and horizontal line)- Video output: VGA, NTSC (VBS), Y/C synchronous outputsCCTV (VGA) systemRef. No.123456Part No.06AAV87606AAV87506AAV87706AAV878972031Description1/2-inch color cameraControllerColor monitor unitCamera cableC-mount adapter (C)User's ManualQty111111CCDManufactured by SONYLength: 3mCommon to 176-372RemarkColor TV (VGA) System No. 06AAV874,which includes the accessory set ofRef. Nos. 1 to 4 (common to the orderNo. 176-372 CCD Color TV System)Real field of view (mm) on the monitor can be obtained from CCD camera's imaging device pixels (VxH)/Objective magnification.13


TP7M ( high-accuracy )High-Accuracy Touch Trigger ProbeThis is a high-accuracy touch trigger probe with a maximum repeatability of 2σ≤0.25μm.change of probe orientationsSince the TP7M can be mounted on a probe head, such as the PH10M/PH10MQ thatautomatically changes the probe orientation, it can greatly reduce the preparation time formeasurement and for actual measurement in comparison to a conventional-type scanningprobe with a position that is fixed downward. In addition, the use of other probes, asadvantaged by the probe change system, makes it possible to realize full automation inmeasuring various forms of machined parts.The TP7M can mount a long stylus up to 180 mm long*. In combination with the longestextension of 200 mm equipped for the PH10M/PH10MQ, it can reach a position at amaximum distance of 380 mm.* This maximum length may vary with the coordinate measuring machine main unit beingused and/or the material/diameter of the stylus itself.TP7M SpecificationsTP7MMeasuring directionStandard stylusRepeatability (2 )Directionality (XY: 2D)Required force to generatetrigger signalAmount of over-travelRequired force to achieveover-travelMaximum stylus lengthStylus mounting methodMass of a single unitDurabilityProbe headApplicable modelsXYZXYZXYZ±X, ±Y, +Zø4X18mm0.25 m or less (When the standard stylus is used.)±0.25 m or less0.02N (When the 50mm stylus is used.)0.15N (When the 50mm stylus is used.)±16º±5mm0.49N (When the 50mm stylus is used.)2.94N (When the 50mm stylus is used.)150mmM4 screw85g10,000,000 timesEssential: PH10M/PH10MQCNC coordinate measuring machines14


TP7M ( high-accuracy )High-Accuracy Touch Trigger Probeø25mmRENISHAW18mm3mm50mmø4mmder No. 916483]Unit : mmUnitRef. DescriptionNo.1 Touch trigger probe TP7M2 Joint key S10Part No. Mass(g)916486 85174748 24Qty11RemarkM4-stylus mount Automatic joint1 15ø251634M4-stylus toolM2-stylus tool1812791531403.50.722For attaching/detachingthe stylus5017TP7M probestylus setNo. 9164845678910111213141516Stylus ø8X100 (M4)Stylus ø8X50 (M4)Stylus ø4X18 (M4)Stylus ø2X19 (M4)Stylus ø1X19.5 (M4)Stylus ø30 ceramic (M3)Stylus ø5X21 (M3)Stylus ø0.5X20 (M3)Stylus ø6X10 (M2)Stylus ø3X10 (M2)Extension L100Extension L759164889164879164919164909164899164921638731638711602191531361812851812846.85.32.22.22.515.31.51.00.90.46.35.3111411121511Standard stylusM4 male - M3 femaleM4 male - M3 female23456781819202122232425171819Extension L50Extension L20Extension L501812831812821812814.63.26.8111M4 male - M3 femaleM4 male - M3 femaleM4926272021Extension L30Extension L301812801602295.11.411M4M21028222324252627Extension L20Extension L10Adapter L9Adapter L5MS4-stylus centerMS3-stylus center1602281602271812861602319164931686770.90.41.30.6123.3112511M2M2M4 male - M3 femaleM4 male - M3 femaleM4M3111213293031ø25ø252829MS2-stylus centerWooden box1602309164941.070011M21432ø25ExtensionsetNo. 91648530313233Probe extension PEM1Probe extension PEM2Probe extension PEM3Wooden box91649591649691649791649865901506001111L50L100L2003334User's Manual916499100115


TP200High-Accuracy Touch Trigger ProbeThis touch trigger probe has an outside diameter as small as ø13.5 mm, which greatlycontributes to probing complex portions of a workpiece. With the combined use of anappropriate probe extension it can probe even deeper locations.-Since the TP200 can be mounted on a probe head, such as the PH10M/PH10MQ thatautomatically changes the probe orientation, it can drastically reduce the time required toprepare for measurement and for actual measurement in comparison to a conventionaltypescanning probe with a position that is fixed downward.If the measurement cannot be performed by merely changing the probe orientation(such as when it is impossible to measure without replacing the normal stylus with onethat has a different diameter or unique form), this automatic stylus change via the styluschange system allows full-automatic measurement to be completed without being interruptedmid-course. In addition, working with other probes, as advantaged by the probechange system, makes it possible to realize full automation in measuring various forms ofmachined parts.TP200 specificationsTP200SCR200(optional)Measuring directionRepeatability (2 )Directionality (XY: 2D)Directionality (XYZ: 3D)Required force to generatetrigger signalAmount of over-travelRequired force to achieveover-travelMaximum stylus lengthMaximum stylus massStylus mounting methodMass of a single unitDurabilityProbe headApplicable modelsNote:Stylus module replacementaccuracyNumber of stylus modules thatcan be mountedXYZXYZXYZ±X, ±Y, ±Z0.3 m or less (with 10mm stylus), 0.4 m or less (with the 50mm stylus)±0.4 m or less (with 10mm stylus), ±0.8 m or less (with the 50mm stylus)±0.65 m or less (with 10mm stylus), ±1 m or less (with the 50mm stylus)0.02N (STANDARD/LOW FORCE), where a 50mm stylus is used.0.07N (STANDARD/LOW FORCE), where a 50mm stylus is used.XY±14º+4.5mm (with 0.07N), +3mm (with 0.15N)0.35N (STANDARD FORCE)0.1N (LOW FORCE)4N (STANDARD FORCE)1N (LOW FORCE)50mm (STANDARD FORCE)30mm (LOW FORCE)8g (STANDARD FORCE), 3g (LOW FORCE)M2 screw22g10,000,000 timesEssential: PH10M/PH10MQ/MIH/PH1CNC coordinate measuring machinesAny stylus less than ø1mm should be used with the LOW FORCE module.Repeated positioning accuracy: 1.0 m or less (through automatic change), when a 50mm stylus is used.*2.0 m or less at a manual replacement: when a 50mm stylus is used.Maximum 6 units16


TP200High-Accuracy Touch Trigger ProbeM8ø13.5mmTP200Probe main unitM2X0.4RENISHAW10mm 13mm 30mmStylus moduleø4mm40TouchtriggerprobeTP200 setOrder No.06AAL268A completeset of TP200probeNo.06AAL251Stylus setfor TP200No.06AAL252Ref. No. Description Part No. Qty Remark123456789101112131415TP200 probeStylus module (standard)Cleaning toolSingle-ended wrenchDouble-ended wrenchStylus toolStylus ø3X10 (M2)Stylus ø6X10 (M2)Stylus ø4X20 (M2)Extension 40mm (M2)Extension 50mm (M2)Carbon extension attachment toolWooden boxUser's ManualCertificate06AAL25306AAL25406AAL25616153416153515314015313616021916022106AAL25706AAL25806AAL26406AAL26506AAL623111111111111111Standard measuring force (at over-travel)For cleaning the stylus moduleFor attaching/detaching the probe (S1)For attaching/detaching the probe (S9)For attaching/detaching the stylus (S7)Standard stylusCarbon fiberCarbon fiberStylus storage box12345610111213141550789Unit : mmAutomatic stylus change system kit (Order No. 06AAL540)No.Description1 Stylus module (low measuring force)2 Stylus module (standard)3 SCR200 kit4 PL63Part No. Qty06AAL255 106AAL254 306AAL267 106AAM887 1Specification (use)For ball stylus less than ø1With a rack mount kitPI200-SCR200 connection cableMass (kg)0.010.010.930.1517


TP20Touch Trigger ProbeThis touch trigger probe has an outside diameter as small as ø13.2 mm, which greatlycontributes to probing complex portions of a workpiece. With the combined use of anappropriate probe extension it can probe even deeper locations.-Since the TP20 can be mounted on a probe head such as the PH10M/PH10MQ thatautomatically changes the probe orientation, it can drastically reduce the time required toprepare for measurement and for actual measurement in comparison to a conventionaltypescanning probe that has a position fixed downward (when it is mounted on the CNCcoordinate measuring machine).If the measurement cannot be achieved by simply changing the probe orientation (such aswhen it is not possible to make measurements without replacing the normal stylus withone having a different diameter or unique form), automatic stylus change via the styluschange system allows full-automatic measurement to be completed without mid-courseinterruption. In addition, the use of other probes as advantaged by the probe change systemmakes it possible to realize full automation in measuring various forms of machinedparts (when it is mounted on the CNC coordinate measuring machine).TP20 SpecificationsTP20MCR20(optional)Measuring directionRepeatability (2 )Directionality (XY: 2D)Directionality (XYZ: 3D)Required force togenerate trigger signalAmount of over-travelRequired force to achieveover-travelMaximum stylus lengthXYStylus mounting methodMass of a single unitDurabilityProbe headApplicable modelsProbe module replacementaccuracyNumber of stylus modules thatcan be mountedZXYZXYZ±X, ±Y, +Z0.35 m or less±0.8 m or less (with the STANDARD FORCE 10mm stylus), ±2.5 m or less (with the 50mm stylus)±1 m or less (with the STANDARD FORCE 10mm stylus), ±4 m or less (with the 50mm stylus)0.08N (STANDARD FORCE), with 10mm stylus0.1N (MEDIUM FORCE), with 25mm stylus0.1N (EXTENDED FORCE), with 50mm stylus0.75N (STANDARD FORCE)1.9N (MEDIUM FORCE)3.2N (EXTENDED FORCE)±14º+4.0mm (STANDARD FORCE)+3.7mm (MEDIUM FORCE)+2.4mm (EXTENDED FORCE)0.2 to 0.3N (STANDARD FORCE)0.2 to 0.4N (MEDIUM FORCE)0.2 to 0.5N (EXTENDED FORCE)3.5N (STANDARD FORCE)7N (MEDIUM FORCE)10 (EXTENDED FORCE)50mm (STANDARD FORCE)60mm (MEDIUM FORCE)60mm (EXTENDED FORCE)M2 screw22g (probe body: 13g, probe module: 9g)1,000,000 timesEssential: PH10M/PH10MQ/MIH/PH1Manual/CNC coordinate measuring machinesRepeatability positioning accuracy: 1.0 m or less (through automatic change), when a 10mm stylus is used.*2.0 m or less at a manual replacement: when a 10mm stylus is used.Maximum 6 units18


TP20Touch Trigger ProbeM8ø13.2mmProbe main unit19mmProbe moduleM2X0.43mm10mm 19mmø4mmder No. 06AA158TouchtriggerprobeTP20 setOrder No.06AAV547Ref. No. Description Part No. Qty Mass Specification (use)12345678910TP20 probe main unitProbe module [STANDARD]Probe module [MEDIUM]ø4X10mm stylusCleaning toolSingle-ended wrenchDouble-ended wrenchStylus toolUser's ManualCertificate06AAV54206AAV54306AAV544–06AAL25616153416153515314099MCA060111111211113g9g9g0.4g54g5g5g1g100g1g450gMeasuring force (small)Measuring force (medium)Standard stylusFor cleaning stylus moduleFor attaching/detaching probeFor attaching/detaching stylusTotal mass including package23467910Standard force moduleMedium force moduleExtended force moduleEM1-STD (Standard force module with extension)EM2-STD (Standard force module with extension)The extension andprobe module areintegrated andcannot beseparated.PrMCR20 setOrder No.06AAV54611.3kgAccessories 1 2(standard force) 119


TP2-5WThis touch trigger probe has an outside diameter as small as ø13 mm, which greatlycontributes to probing complex portions of a workpiece. With the combined use of anappropriate probe extension it can probe even deeper locations.change of probe orientationSince the TP2-5W can be mounted on a probe head such as the PH10M/PH10MQ thatautomatically changes the probe orientation, it can drastically reduce the time required toprepare for measurement and for actual measurement in comparison to a conventionaltypescanning probe that has a fixed position downward. With the combined use of anappropriate probe extension it can probe even deeper locations (when it is mounted onthe CNC coordinate measuring machine).TP2-5W SpecificationsTP2-5WMeasuring directionRepeatability (2 )Directionality (XY: 2D)Directionality (XYZ: 3D)Required force to generatetrigger signalAmount of over-travelRequired force to achieveover-travelStylus mounting methodMass of single unitDurabilityProbe headApplicable modelsXYZXYZXYZ±X, ±Y, +Z0.35 m or less±0.8 m (with 10mm stylus), ±2.5 m (with the 50mm stylus)±1 m (with 10mm stylus), ±4 m (with the 50mm stylus)0.07 to 0.15N (Variable. Standard: 0.07N)0.7N (when the X and Y axis are set to standard)XY±14º, Z+4mm (when the required force to generate trigger signal is 0.07N)±4mm (when the required force to generate trigger signal is 0.07N), +3mm (at 0.15N)0.2 to 0.4N4N (when the required force to generate trigger signal is 0.07N)M2 screw22g1,000,000 timesEssential: PH10M/PH10MQ/MIH/PH1Manual/CNC coordinate measuring machines20


TP2-5WM8ø13mm3mm38mmM2X0.4Set configurationNo. Description Part No.Qty Mass (kg) Remark12TP2-5WPH1 (ø14)538414932877A110.0220.12534567891011121314151617181920Carbon fiber extension barStylusSingle-ended wrenchDouble-ended wrenchMS2-stylus toolAllen keys (4-piece set)Storage boxUser's ManualCertificateSignal cableSignal cableSignal cable06ABM15206ABM15306ABM154————13539916153416153515314090896106AAN446154613932878935793908462111111111111 for each111* See the table below.* See the table below.* See the table below.0.0240.0570.0860.00040.00040.00030.00050.00440.0050.0050.0020.0061.30.10.010.20.050.05L=50mmL=100mmL=200mmø3X10mm standard stylusø2x20mmø1x10mmø3x20mmCarbon fiber ballFor attaching/detaching the probeFor attaching/detaching the probeFor attaching/detaching the stylus5P-5P straight, 5m5P-5P curl code5P-12P curl codeø142 1 15ø13181436503819ø3017ø1352020016ø13410103ø1350100131112ø3ø220ø1ø36 7 8 920ø1"1017Set order No.06ABM32806ABM32906ABM33006ABM155ConfigurationNo.1 - 18No.1 - 17, 19No.1 - 17, 20No.1 - 17Mass (kg)1.9481.7981.7981.748RemarkWith signal cable (5P-5P straight, 5m)With signal cable (5P-5P curl code)With signal cable (5P-12P curl code)Signal cable: NoneUnit : mmder No. 916148]No. Description Part No. Qty123456789Touch trigger probe TP2-5WStylus ø3X10mmStylus ø2X20mmStylus ø1X10mmStylus ø3X20mmStylus tool S7Allen keys (2 sizes)Storage boxUser's Manual538414————1531409161499161501546131111121 for each11ø133812 3 4 5ø3107ø220ø11020ø38 96Unit : mm21


MH20iThis series of touch trigger probes has a manually operable probe head for coordinatemeasuring machines. The probe module part has an outside diameter as small as ø13.2mm, which greatly aids in probing complex portions of a workpiece. Other probe modulesemploying an extension either 50 mm long or 70 mm long are also provided.The probe head part of the MH20i has a structure that not only permits its position (probeorientation) to be manually changed but also provides a maximum of 168 orientations(at a positioning repeatability σ≤1.5μm). Even for measurement of a complex threedimensionalform that requires repeated changes in the probe orientation, preliminaryregistration of required positions can eliminate re-calibration after each positional change,thereby broadly improving the measurement efficiency.MH20i SpecificationsMH20iMeasuring directionPosition changeRepeated positioning accuracyRepeatability (2 )Directionality (XY: 2D)Directionality (XYZ: 3D)Required force to XYgenerate triggersignalZAmount ofover-travelRequired force toachieve over-travelMaximum stylus lengthXYZXYStylus mounting methodMass of a single probe unitDurabilityProbe headApplicable modelsZ±X, ±Y, +ZManually for A axis (vertical direction): 0 to 90º (at 15º increments),and for B axis (horizontal direction): ±180º (at 15º increments)ʺ 1.5 m0.35 m or less±0.8 m or less (with the STANDARD FORCE 10mm stylus), ±2.5 m or less (with the 50mm stylus)±1 m or less (with the STANDARD FORCE 10mm stylus), ±4 m or less (with the 50mm stylus)0.08N (STANDARD FORCE), with the 10mm stylus0.1N (MEDIUM FORCE), with the 25mm stylus0.1N (EXTENDED FORCE), with the 50mm stylus0.75N (STANDARD FORCE)1.9N (MEDIUM FORCE)3.2N (EXTENDED FORCE)±14º+4.0mm (STANDARD FORCE)+3.7mm (MEDIUM FORCE)+2.4mm (EXTENDED FORCE)0.2 - 0.3N (STANDARD FORCE)0.2 - 0.4N (MEDIUM FORCE)0.2 to 0.5N (EXTENDED FORCE)3.5N (STANDARD FORCE)7N (MEDIUM FORCE)10N (EXTENDED FORCE)50mm (STANDARD FORCE)60mm (MEDIUM FORCE)60mm (EXTENDED FORCE)M2 screw250g1,000,000 timesNot requiredManual/CNC coordinate measuring machines22


MH20iø14mmø48mmMH20iMH20iMH20iMH20i53mm77mm015304519.5mmProbe module5.7mm10mmSet ConfigurationMH20i single unitOrder No.06ABN436MH20i setOrder No.06ABN470Ref. No. Description Part No. Qty Mass (kg) Remark123456789MH20iProbe moduleCleaning toolMS2-stylus toolPositioning shankStylusAllen key (2mm)Allen key (3mm)Operation Manual06ABN46906AAV54306AAL256153140160589—06AAA94306AAA94499MCA265J1111111110.250.010.050.0030.150.0010.0010.0010.1STANDARD TYPEFor cleaning the stylus moduleFor attaching/detaching the stylusø4X10 (standard stylus)57MH20iMH20i38011530454296Standard foreee23


MH20This trigger probe has a manually operable probe head for coordinate measuring machines.The probe module part has an outside diameter as small as ø13.2 mm, whichgreatly aids in probing complex portions of a workpiece. Other probe modules employingan extension either 50 mm long or 70 mm long are also provided.The operator can change the probe orientation in an optional direction by hand (simplyloosen the knob on the right-hand side and change the position, then re-fasten the knob).No Allen key or other tools are required for the positional change.MH20 SpecificationsMH20Measuring directionPosition changeRepeatability (2 )Directionality (XY: 2D)Directionality (XYZ: 3D)Required force to XYgenerate triggersignalZAmount ofover-travelRequired force toachieve over-travelMaximum stylus lengthXYZXYStylus mounting methodMass of a single probe unitDurabilityProbe headApplicable modelsZ±X, ±Y, +ZManually for A axis (vertical direction): ±93º, and for B axis (horizontal direction):To be fixed to optional direction in range of ±300º0.35 m or less±0.8 m or less (with the STANDARD FORCE 10mm stylus), ±2.5 m or less (with the 50mm stylus)±1 m or less (with the STANDARD FORCE 10mm stylus), ±4 m or less (with the 50mm stylus)0.08N (STANDARD FORCE), with the 10mm stylus0.1N (MEDIUM FORCE), with the 25mm stylus0.1N (EXTENDED FORCE), with the 50mm stylus0.75N (STANDARD FORCE)1.9N (MEDIUM FORCE)3.2N (EXTENDED FORCE)XY±14º+4.0mm (STANDARD FORCE)+3.7mm (MEDIUM FORCE)+2.4mm (EXTENDED FORCE)0.2 to 0.3N (STANDARD FORCE)0.2 to 0.4N (MEDIUM FORCE)0.2 to 0.5N (EXTENDED FORCE)3.5N (STANDARD FORCE)7N (MEDIUM FORCE)10N (EXTENDED FORCE)50mm (STANDARD FORCE)60mm (MEDIUM FORCE)60mm (EXTENDED FORCE)M2 screw22g (Probe body: 13g, Probe modulel: 9g)1,000,000 timesEssential: PH10M/PH10MQ/MIH/PH1Manual/CNC coordinate measuring machines24


93ºMH20ø14Unit: mm24MH209047CenterClamp93º10Probe moduleRotating ±300ºSet ConfigurationMH20-setstandardconfigurationOrder No.06AAZ727No.123Description1-1 MH20MH20 1-2 TP20 standard modulekit No. 1-3 Stylus06AAZ726 1-4 Cleaning kit1-5 MS2-stylus toolOperation ManualCertificatePart No.06AAZ72806AAV54316021706AAL256153140Qty Mass (kg) Remark11112110.30.10.01Probe head main unitMeasuring force (small)ø4X10 (standard stylus)For cleaning the probe module connectionStylus attachment tool1-11-31-41-2RENISHAWMH201-525


PHC10-2PH10M/PH10MQMotorized Probe Head62mmø14mmPH10MQ adapter38mm130mm38mm73mm73mmAutojoint section80mmAutojoint section32mmPAA1PECF150mmPECF2100mmPECF3200mm300mmPAA350mmPEM1100mmPEM2200mmPEM3Set configurationNo. Description Part No. Qty RemarkMass (kg)123456PH10Mhead setPH10MQhead setHCU-1PHC10-2 (RS232C)PAA1User's Manual1PH10M headJoint key S10Allen key (nominal 1.5)Allen key (nominal 2)Allen key (nominal 2.5)PH10MQ headJoint key S10Allen key (nominal 1.5)Allen key (nominal 2.5)*17474890875606AAA94306AAA944*17474890875606AAA94406AAN82006AAR54790946099MCA034111211111Controller for positioning the probe headInterface with the machine-side CPU (for error display)Adapter for mounting the TP200 onto the PH10MUser's Manual for PH10M head2 3 4 52.02.00.82.20.060.1* Each part number will differ depending on the CMM main unit/probe that uses it. Some additional parts are also available.627


MIHManual Probe HeadThe MIH has such a capability that permits its position (probe orientation) to be manuallychanged to maximum 168 kinds of orientations at a positioning repeatability of σ≤1.5μm.For measurement of a complex three-dimensional form that requires repeated changesin the probe orientation, preliminary registration of required positions can eliminate recalibrationafter each positional change, therefore improving the measurement efficiencyat large. The current position can of course be confirmed on the LCD display of the MIHmain unit.The MIH can employ any probe extension that is a maximum of 300 mm long. An examplecombination of the TP2-5W and a 50 mm stylus can extend the probe’s reach to approximately400 mm.MIHPosition changeRepeated positioning accuracyMountable probeExtensionApplicable modelsHorizontal direction ±180º (at 7.5 increments, 48 positions)Vertical direction 0 to 105º (at 7.5 increments, 15 positions)ʺ 1.5 mTP200, TP20, TP2-5wPAA1 (PAA1+PECF1, PAA1+PECF2, PAA1+PECF3), PAA2, PAA3Manual coordinate measuring machines28


MIHManual Probe Headø14mm111mm76.5mmRENISHAW MIHAutojoint sectionø62mmSet configurationNo. Description Part No. Mass (kg) Qty1234567MIHhead kitsetOrder No.06AAB126MIH headJoint key S10Allen key (nominal 2)Allen key (nominal 2.5)Battery PX28LWooden box for MIHPAA1Single-ended wrenchDouble-ended wrenchPositioning shankCertificateUser's Manual06AAB12717474806AAA94306AAA94406AAB12806AAB1299094601615341615351605891.50.060.010.0050.140.0010.05111121111111RemarkTraveling angle: Horizontal (B axis) ±180º (7.5º steps, 48 positions)Vertical (A axis) 0 to 105º (7.5º steps, 15 positions)Spatial positioning accuracy: ±0.3mm (where PAA1+TP2-5W+ø3 stylus+EWL7.5 is used)Repeated positioning accuracy ( ): 1.5 m (in the same case as above)Mass: Approx. 730gFor attaching the probeFor adjusting the positioning block, or battery replacementFor attaching the shank6V lithium cell (Manufacturer: Duracell)Adapter for connecting the MIH and probe. Length: 32mmFor fastening the TP2 and extensionFor fastening the TP2 and extensionTo be attached on the MIH head (Mitutoyo)PECF150mmPECF2100mmPECF3200mm200mmPEL329


PH1Manual Probe HeadManual probe head for use with the TP200, TP20, and TP2-5W.The operator can change the probe orientation to an optional direction by hand.It is possible to insert a probe extension that is a maximum of 200 mm long.PH1 specificationsPosition changeMountable probeExtensionApplicable modelsHorizontal direction 360º (at 15º increments)Possible in a non-stop manner, if the head is rotated along withthe ø14mm shank unit.Vertical direction ±115º (non-step)TP200, TP20, TP2-5WPECF1, PECF2, PECF3Manual/CNC coordinate measuring machines30


PH1Manual Probe Headø41mmø14mm36mm50mmM8ø30mmPECF150mm100mmPECF2200mmPECF3An example connection of PECF331


ACR-3Releasingthe lockEngagingthe lockThe ACR3 is an automatic probe changer for use with the PH10M/PH10MQ. It is essentialfor full-automatic measurements where the currently employed probe does not have thecapability of automatic stylus change but the stylus diameter or length must be occasionallychanged, and where the contact-type probe and non-contact type probe are switchedas required.In comparison to the conventional automatic probe changer, which must have a dedicatedmotor built in to turn on and off the lock system, is expensive, and has poor durability, theACR3 has a simplified structure and improved durability because it employs a new mechanismin which the automatic probe change is performed through the CNC coordinatemeasuring machine’s own drive system.32


ACR-3Unit : mm185610147Free areaUNLOCKED88.7Free areaLOCKED333106CENTER POSITION16Set configuration4-port system[Order No.06ABP469]8-port system[Order No.06ABP470]No. Description Part No. Qty Mass (kg) Remark123456123456ACR3MRS KIT2Auxiliary plateACR3 attachmentUser's ManualControl ROMACR3MRS KIT2Auxiliary plateACR3 attachmentUser's ManualControl ROM06ABN43806ABN60706ABG598406ABP46706ABN43806ABN60706ABG598406ABP4671111112111111.53.580.050.10.011.53.580.050.10.014-port rackRack baseFor fixtureAttachmentAdaptive to ACR34-port rackRack baseFor fixtureAttachmentAdaptive to ACR313 4233


Ceramic Master BallCeramic master ball (standard type) m or less±0.01mmø20 ceramic ball2O3 (99.9%)]ø15ø7.5 m or less0-0.02ø20 ceramic ball2O3 (99.9%)]ø15ø7.5ø23(12)141163430ø23(12)114116330BaseBase for a ceramic master ball14119190.520 32Base appearanceSet break-downsSet order No.Set nameCeramicmaster balltypeInspectionCertificateBaseCalibrationCertificateTraceability06ABQ041A06ABQ041B06ABQ040A06ABQ040B06ABQ044A06ABQ044BA setA3 setB setB3 setC setC3 setStandardStandardStandardStandardOptional accessory for the Ceramic Master BallSpacer19124190.520 32Spacer appearance34


MPP-300Q/MPP-300 Page 2 SP80 Page 4 SP25M Page 6 MPP-100 Page 8QVP Page 10 CF20 Page 12 TP7M Page 14 TP200 Page 16TP20 Page 18 TP2-5W Page 20 MH20i Page 22 MH20 Page 24PH10M/PH10MQ Page 26 MIH Page 28 PH1 Page 30 ACR-3 Page 3235


One Number to Serve You Better1-888-MITUTOYO (1-888-648-8869)Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance datacontained in this printed matter as well as other technical data are to be regarded as approximate average values. We thereforereserve the right to make changes to the corresponding designs. The stated standards, similar technical regulations, descriptionsand illustrations of the products were valid at the time of printing. In addition, the latest applicable version of our GeneralTrading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive.Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of Mitutoyo products mayrequire prior approval by an appropriate governing authority.Trademarks and RegistrationsDesignations used by companies to distinguish their products are often claimed as trademarks. In all instances where MitutoyoAmerica Corporation is aware of a claim, the product names appear in initial capital or all capital letters. The appropriatecompanies should be contacted for more complete trademark and registration information.We reserve the right to change specifications and prices without notice.Aurora, Illinois(Corporate Headquarters)Westford, MassachusettsHuntersville, North CarolinaMason, OhioPlymouth, MichiganCity of Industry, California