Series 505···<br />

Suspended luminaires with semi-specular parabolic louvre RMV<br />

654da<br />

Application<br />

Offices, sales areas, showrooms and financial<br />

institutions. Especially recommended for VDU<br />

workstations.<br />

Optical system<br />

Direct/indirect. Micro-segmented parabolic<br />

louvre RMV made of semi-specular anodised<br />

aluminium with a surface purity of 99.98 %<br />

for especially high light output. Suitable<br />

for VDU applications in accordance with<br />

EN 12464-1 due to low luminance<br />

L ≤ 1000 cd/m 2 at critical angles above 65° in<br />

all planes. Louvre retention by means of<br />

spring-tensioned clips, providing earth continuity.<br />

Louvre can be lowered and hung from<br />

either side without tools.<br />

Luminaire body<br />

Powder-coated sheet steel, white. Elegant<br />

rectangular design with longitudinal 40 mm<br />

wide rim. Luminaire body with integral<br />

coupling brackets for precisely aligned continuous<br />

lines with optically continuous louvres.<br />

End caps for individual luminaires or for the<br />

completion of continuous lines to be ordered<br />

separately.<br />

Control gear option<br />

Versions ···/28/54··· and ···35/49/80··· in<br />

Multi-Lamp technology allow operation of<br />

T5 lamps with different wattages.<br />

···E With electronic control gear.<br />

···EDD With digitally dimmable electronic<br />

control gear (DALI).<br />

IP20 0.2 Joule 650 °C<br />

Other electrical versions available on request.<br />

5051 RMV-L···<br />

Accessories ······························234<br />

Lamp characteristics ···············525<br />

5051 RMV-L···<br />

Reference* TOC Control gear Lamps D D1 ≈kg<br />

option<br />

···E ···EDD W mm<br />

5051 RMV-L/28/54··· 47 767··· ···04 ···07 1 x 28/54 1193 11 3.0<br />

5051 RMV-L/35/49/80··· 47 774··· ···04 ···07 1 x 35/49/80 1493 11 3.6<br />

5051 RMV-L/2x28/54··· 51 762··· ···04 ···07 2 x 28/54 1193 11 3.1<br />

5051 RMV-L/2x35/49··· 51 763··· ···04 ···07 2 x 35/49 1493 11 3.7<br />

5051 RMV-L/2x80··· 47 772··· ···04 ···07 2 x 80 1493 11 3.9<br />

*End caps for individual luminaires or continuous lines to be ordered separately.<br />

C0-C180<br />

5051 RMV-L/49<br />

UTE: 0.44 B + 0.23 T<br />

DIN 5040: B63<br />

CIBSE: BZ 2/1.5/BZ 1<br />

NBN L 14-002: BZ 1