Views
2 years ago

RAE ppbRAE 3000 User's Guide - Geotech

RAE ppbRAE 3000 User's Guide - Geotech

ppbRAE

ppbRAE 3000 User’s Guide3. Once you are in one of the categories, press [N/-] to scrollthrough its list of options and [Y/+] to select one. (If youpress [MODE], you exit to the next submenu.)4. Press [Y/+] to save your choice or [N/-] to undo yourselection.Leave the sub-menu and return to the Programming Mode menus bypressing [MODE].Meas. UnitStandard available measurement units include:Abbreviation Unitppm parts per millionppb parts per billionmg/m3 milligrams per cubic meterug/m3 micrograms per cubic meter• Scroll through the list by pressing [N/-].• Select by pressing [Y/+].• Save your selection by pressing [Y/+] or undo your selection bypressing [N/-].Leave the sub-menu and return to the Programming Mode menus bypressing [MODE].54

ppbRAE 3000 User’s GuideAlarm SettingDuring each measurement period, the gas concentration is comparedwith the programmed alarm limits (gas concentration alarm limitsettings: Low, High, TWA and STEL). If the concentration exceedsany of the preset limits, the loud buzzer and red flashing LED areactivated immediately to warn of the alarm condition.An alarm signal summary is shown on page 27.In this menu, you can change the High and Low alarm limits, theSTEL limit, and the TWA. Press [Y/+] to to enter the Alarm Settingmenu. Note: All settings are shown in ppm (parts per million), ormg/m 3 (milligrams per cubic meter), depending on your setting.1. Scroll through the Alarm Limit sub-menu using the [N/-] keyuntil the display shows the desired limit to be changed (HighAlarm, Low Alarm, STEL Alarm, and TWA Alarm)2. Press [Y/+] to select one of the alarm types. The displayshows a flashing cursor on the left-most digit of thepreviously stored alarm limit.3. Press [Y/+] to increase each digit’s value.4. Press [N/-] to advance to the next digit.5. Again, use [Y/+] to increase the number.Repeat this process until all numbers are entered.Press [MODE] when you are done.• Press [Y/+] to save the changes.• Press [N/-] to undo the changes and revert to the previoussettings.When all alarm types have been changed or bypassed, press [MODE]to exit to the Programming Menu.55

NexSens WQ-ORP Sensor User's Manual - Geotech Environmental ...
Thermo Scientific Orion Star A325 Reference Guide - Geotech ...
Thermo Scientific Orion Star A326 Reference Guide - Geotech ...
Thermo Scientific Orion Star A222 Reference Guide - Geotech ...
MC65 User Guide [English] (P/N 72E-133769-01 Rev. B)
MC9500-K MOBILE COMPUTER USER GUIDE
PDF user guide for the monitor - Npower
MC21XX Series Mobile Computer User Guide - Portable ...
BigTel 202 User Guide - Hearing Direct
BigTel 200 User Guide - Hearing Direct
GP680 Basic User Guide 6864110B19-B - Co-Channel
GP360 Basic User Guide - SOVT-Radio sro
Work Sharp 3000 User Guide .PDF - Highland Woodworking
User Guide - How To & Troubleshooting - Sony.com
FrontRow Pro 940H User guide - Centrum Sound
Download Gp340 Basic User Guide - Radio Facilities
2110XP Ammonia Analyzer User Guide
Pandigital Novel User Guide - DevDB
BT Lyric 2100 User Guide - UkCordless