Views
3 years ago

RAE ppbRAE 3000 User's Guide - Geotech

RAE ppbRAE 3000 User's Guide - Geotech

ppbRAE

ppbRAE 3000 User’s GuideSpecial NotesWhen the instrument is taken out of the transport case andturned on for the first time, there may be some residual organicor inorganic vapor trapped inside the detector chamber. Theinitial PID sensor reading may indicate a few ppm. Enter anarea known to be free of any organic vapor and turn on theinstrument. After running for several minutes, the residualvapor in the detector chamber will be cleared and the readingshould return to zero.The battery of the instrument discharges slowly even if it isturned off. If the instrument has not been charged for 5 to 7days, the battery voltage will be low. Therefore, it is a goodpractice to always charge the instrument before using it. It isalso recommended to fully charge the instrument for at least10 hours before first use. Refer to this User Guide’s section onbattery charging for more information on battery charging andreplacement.6

ppbRAE 3000 User’s GuideWARNINGSSTATIC HAZARD: Clean only with damp cloth.For safety reasons, this equipment must be operated andserviced by qualified personnel only. Read and understandinstruction manual completely before operating or servicing.Use only RAE Systems battery packs, part numbers 059-3051-000,059-3052-000, and 059-3054-000. This instrument has not beentested in an explosive gas/air atmosphere having an oxygenconcentration greater than 21%. Substitution of components mayimpair intrinsic safety. Recharge batteries only in non-hazardouslocations.Do not mix old and new batteries or batteries from differentmanufacturers.The calibration of all newly purchased RAE Systems instrumentsshould be tested by exposing the sensor(s) to known concentrationcalibration gas before the instrument is put into service.For maximum safety, the accuracy of the instrument should bechecked by exposing it to a known concentration calibration gasbefore each day’s use.Do not use USB/PC communication in hazardous locations.7

NexSens WQ-ORP Sensor User's Manual - Geotech Environmental ...
Thermo Scientific Orion Star A222 Reference Guide - Geotech ...
MC65 User Guide [English] (P/N 72E-133769-01 Rev. B)
MC21XX Series Mobile Computer User Guide - Portable ...
MC9500-K MOBILE COMPUTER USER GUIDE
PDF user guide for the monitor - Npower
Work Sharp 3000 User Guide .PDF - Highland Woodworking
Thermo Scientific Orion Star A325 Reference Guide - Geotech ...
Thermo Scientific Orion Star A326 Reference Guide - Geotech ...
BigTel 200 User Guide - Hearing Direct
BigTel 202 User Guide - Hearing Direct
download user guide - Ray Displays
GP640 Basic User Guide - Co-Channel
Multi-Room DVR User Guide - Waitsfield Cable
GP360 Basic User Guide - SOVT-Radio sro
Alcatel-Lucent DECT Phones 300 & 400 User Guide - Onedirect
LANTEK CABLE TESTER USER'S GUIDE - Ideal Industries
BT Synergy 3505 User Guide - UkCordless
Diverse 5110 User Guide - CPC Office Supplies
BT Freelance 3100 user guide - UkCordless
BT Calypso 1100 User Guide - UkCordless
Pandigital Novel User Guide - DevDB
FrontRow Symbio User Guide - Centrum Sound