RAE ppbRAE 3000 User's Guide - Geotech

RAE ppbRAE 3000 User's Guide - Geotech

ppbRAE

ppbRAE 3000 User’s GuideTo install the adapter in the instrument:1. Remove the Li-ion battery pack from the batterycompartment by sliding the tab and tilting out the battery.2. Replace it with the alkaline battery adapter3. Slide the tab back into place to secure the battery adapter.IMPORTANT!Alkaline batteries cannot be recharged. The instrument’s internalcircuit detects alkaline batteries and will not allow recharging. If youplace the instrument in its cradle, the alkaline battery will not berecharged. The internal charging circuit is designed to preventdamage to alkaline batteries and the charging circuit when alkalinebatteries are installed inside the instrument.Note: When replacing alkaline batteries, dispose of old ones properly.WARNING!To reduce the risk of ignition of hazardous atmospheres, recharge thebattery only in areas known to be non-hazardous. Remove and replacethe battery only in areas known to be non-hazardous.Note: The internal charging circuit is designed to prevent charging toalkaline batteries.92

ppbRAE 3000 User’s GuidePID Sensor & Lamp Cleaning/ReplacementThe sensor module is made of several components and is attached tothe lamp-housing unit as shown below.Inlet Probe AssemblyPN 023-3012-000Sensor CoverAssemblySeal NutO-ring, 35mm x 2mmFilter FixerLamp 1/2" (10.6eV)PN 050-0000-004Sensor DetectorPN 023-3010-000Teflon O-ringStainless Steel WasherO-ring, 36.5mm x 2.65mmPorous Metal FilterSensor Module AssemblyPN 023-3005-400-FRUTHP (temperature, humidity, pressure) Sensor ModulePN 023-3011-000-FRUSensor ComponentsNote: The cleaning procedure is not normally needed. Clean the PIDsensor module, the lamp and the lamp housing only when one of thefollowing has happened:1. The reading is inaccurate even after calibration.2. The reading is very sensitive to air moisture.3. A chemical liquid has been sucked into the unit and damagedthe unit.Use of the external filter helps to prevent contamination of the sensor.To access the sensor components and lamp, gently unscrew the lamphousingcap, remove the sensor adapter with the gas inlet probe andthe metal filter all together. Then hold the PID sensor and pull itstraight out. A slight, gentle rocking motion helps release the sensor.93

Thermo Scientific Orion Star A326 Reference Guide - Geotech ...
Thermo Scientific Orion Star A325 Reference Guide - Geotech ...
NexSens WQ-ORP Sensor User's Manual - Geotech Environmental ...
Thermo Scientific Orion Star A222 Reference Guide - Geotech ...
GP680 Basic User Guide 6864110B19-B - Co-Channel
2110XP Ammonia Analyzer User Guide
User Guide - How To & Troubleshooting - Sony.com
FrontRow Pro 940H User guide - Centrum Sound
Download Gp340 Basic User Guide - Radio Facilities
BT Lyric 2100 User Guide - UkCordless
USER GUIDE WIRELESS VGA DEVICE ADAPTER
UC360 Collaboration Point User Guide - Mitel Edocs
DriveRight 600 User's Guide - Davis Instruments Corp.
BT Freelance XD510 User Guide - UkCordless
BT Studio 500 User Guide - UkCordless
SIGNALTEK Users Guide V1.0 English - Ideal Industries
BT Equinox 1200 User Guide - UkCordless
Kindle Fire User's Guide (PDF) - Amazon Web Services
MC65 User Guide [English] (P/N 72E-133769-01 Rev. B)
MC9500-K MOBILE COMPUTER USER GUIDE
MC21XX Series Mobile Computer User Guide - Portable ...
PDF user guide for the monitor - Npower