12.07.2015 Views

OEL ARC Flash Wear - Dixie Construction Products

OEL ARC Flash Wear - Dixie Construction Products

OEL ARC Flash Wear - Dixie Construction Products

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WarningsIMPORTANT SAFETY INFORMATION FOR PPE<strong>ARC</strong> PROTECTION CLOTHING REQUIREMENTSOSHA 29 CFR 1910.269 (l)(6)(iii) “The employer shallensure that each employee who is exposed to the hazardsof flames or electric arcs does not wear clothing that,when exposed to flames or electric arcs, could increasethe extent of injury that would be sustained by theemployee.”Clothing made from acetate, nylon, polyester and rayoneither pure or blended should not be worn when workingin hazardous environments. (see videos showing thishazard at www.oelsales.com)Clothing made from 100% cotton or wool must bedetermined acceptable for the conditions the workerwill be exposed to. Clothing made from flame-resistantmaterials, that meet current ASTM F1506, is acceptable.ASTM F1506 details the specifications of a textile to beused by an electrical worker as a means of electrical arcprotection. A garment must include a label, which statesthe following information: Tracking I.D. Code, Meets ASTMF1506, Manufacturer’s name, Care Instructions & FiberContent, Size, and “Arc Rating” - ATPV or EBT.ASTM F2178 is the test method used to measure arc ratedproducts intended to protect the face of workers exposedto electrical arcs.ALWAYS PERFORM A HAZZARD ASSESSMENTThe NFPA 70E Standard for Electrical Safetyin the Workplace requires employers toperform an Electrical Arc Hazard Assessment.Each situation is unique and needs tobe evaluated on its own merits. ASTMF1959 details the standardized test thatmust be used to determine the thermalprotective value of textiles in an electric arcapplication.Clothing selected for a particular applicationshall have an arc thermal performance valueof (EBT or ATPV) higher than the potentialhazard to prevent the onset of 2nd degreeburns.VISIT OUR WEBSITE FOR:Reviewing our up to date Tool CatalogReviewing our new <strong>ARC</strong> <strong>Flash</strong> Clothing CatalogWitnessing our stunning <strong>ARC</strong> <strong>Flash</strong> VideosReading up on the latest OSHA rules andregulationswww.oelsales.comDANGERS OF <strong>ARC</strong> FLASHEven relatively low voltages can be fatal. For example,electrical shocks produced from common 60 hz AC powerpassing from hand to foot for a duration of one second canhave the following effects:Effects of Electrical ShockCurrentEffects1-3Milliamps3+Milliamps10+Milliamps30+Milliamps60+Milliamps4+Amps5+AmpsTingling SensationShock (pain)Muscular Contractions (can’t let go)Respiratory Paralysis (may be fatal)Ventricular Fibrillation (usually fatal)Heart Paralysis (fatal)Tissue Burning (fatal, vital organsdestroyed)www.oelsales.com 6 1-800-818-2244

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!