12.07.2015 Views

Solar energy Solutions for photovoltaics

Solar energy Solutions for photovoltaics

Solar energy Solutions for photovoltaics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Solar</strong> <strong>energy</strong><strong>Solutions</strong> <strong>for</strong> <strong>photovoltaics</strong>


QatarIn dialog with customers andpartners worldwidePhoenix Contact is a worldwide marketleader in the field of electrical engineeringand automation. Founded almost 90 yearsago, this family company now employsaround 12,800 people worldwide. A salesnetwork with over 46 subsidiaries andmore than 30 additional sales partnersguarantees customer proximity directly onsite, anywhere in the world.Our range of services consists of productssurrounding various different electrotechnical applications.This includes numerous connection technologies <strong>for</strong> deviceand machine manufacturers, components <strong>for</strong> modern controlcabinets, and tailor-made solutions <strong>for</strong> many applications andindustries, such as automobile production, wind <strong>energy</strong>,<strong>photovoltaics</strong>, the process industry or applications in the fieldof water supply, power distribution, and transportationinfrastructure.Global player with personal customercontactCompany independence is an integral part ofour corporate policy. Phoenix Contactthere<strong>for</strong>e relies on in-house competence andexpertise in a range of contexts: the designand development departments constantlycome up with innovative product ideas,developing special solutions to meet customerrequirements. Numerous patents emphasizethe fact that many products have beendeveloped exclusively by Phoenix Contact.2 PHOENIX CONTACT


Photovoltaics –safe <strong>energy</strong> <strong>for</strong> the futureWorldwide <strong>energy</strong> requirements are onthe increase and renewable energies willplay a major role in future from both anecological and economic standpoint.Leading institutes are assuming annualgrowth of between eight and twelvepercent by 2020. Consequently, in the<strong>energy</strong> mix of the future, solar current,including solar current generated bysolar thermal power stations, will meetup to thirty percent of total <strong>energy</strong>requirements. Around two thirds of thispower will be generated via roofsurfaces with solar panels installed.Vacant areas, facades, and traffi c routesoffer additional development potential<strong>for</strong> <strong>photovoltaics</strong>.Design an environmentally-friendly andeconomic power supply with PhoenixContact. For years now, we have been areliable and an expert partner in the PVsector. Our product solutions andservices enable you to operate yoursystems even more safely and effi ciently.Contents<strong>Solutions</strong> <strong>for</strong> <strong>photovoltaics</strong> –Overview 04 – 05<strong>Solutions</strong> <strong>for</strong>– Free-standing systems 06 – 23– Tracking systems 24 – 27– Rooftop systems 28 – 31– Building integration 32 – 35– Autonomous power supply 36 – 37Accessories 38 – 39Service and support 40 – 41Selection tables andtechnical data 42 – 63“With the power of the sunand technology from Phoenix Contact,you can design inspirational solutions<strong>for</strong> a sustainable power supply.”PHOENIX CONTACT 3


<strong>Solutions</strong> <strong>for</strong> <strong>photovoltaics</strong>Whether small rooftop systems on detached houses, tracking systems or free-standingsystems in the megawatt range: <strong>for</strong> reliable and, in particular, effi cient operation, themarket requires easy connection technology solutions featuring long-term stability,complete monitoring and management systems, and comprehensive protection againstsurge voltages. The development of intelligent power supply systems also shapes theelectrotechnical equipment <strong>for</strong> all aspects of <strong>photovoltaics</strong>: network and systemoperators must communicate on a consistent and uni<strong>for</strong>m basis and reliable remotecontrol concepts are indispensable.Free-standing systemsIntelligent connection technology revealsits strengths in the installation of freestandingPV systems. For effi cientoperation, Phoenix Contact offers allstring combiner box components as wellas solutions <strong>for</strong> park management.Tracking systemsTracking systems aim to deliver maximum<strong>energy</strong> yields. With durable and reliabletechnology from Phoenix Contact, you canrest assured that the additional fi nancialexpenditure that these systems involve willbe worthwhile.More in<strong>for</strong>mation from page 6 onwardsMore in<strong>for</strong>mation from page 24 onwards4 PHOENIX CONTACT


Rooftop systemsObviously, rooftop PV systems aresusceptible to damage from lightningstrikes. Protect your systems andconnected systems reliably andpermanently – with powerful surgeprotection.Building integrationBuilding-integrated <strong>photovoltaics</strong> offer hugepotential <strong>for</strong> environmentally-friendly urban<strong>energy</strong> generation. However, the prevailingstructural conditions pose special cablingchallenges. The solution: plug-in connectorsfrom Phoenix Contact.Autonomous power supplyFor independent power supply in thefi eld or wherever you need <strong>energy</strong>,Phoenix Contact offers intelligentsolutions <strong>for</strong> autonomous <strong>photovoltaics</strong>ystems.More in<strong>for</strong>mation from page 28 onwardsMore in<strong>for</strong>mation from page 32 onwardsMore in<strong>for</strong>mation from page 36 onwardsPHOENIX CONTACT 5


<strong>Solutions</strong> <strong>for</strong> free-standing systemsPhotovoltaics make a major contribution toward meeting the continually rising <strong>energy</strong>requirements. Interest in building increasingly larger and more powerful free-standingPV systems is on the increase worldwide. Networking, monitoring, and communicationare indispensable in this regard, particularly in relation to constant network quality andmaintenance in line with requirements. At the same time, in the case of larger systems,the aim is easy and fast connection technology. Discover the advantages of PhoenixContact solutions <strong>for</strong> yourself.“Intelligent technology is impressive if it is simpleto use – irrespective of whether it's connectiontechnology or remote control software.”6 PHOENIX CONTACT


Park managementSensor/actuator cabling <strong>for</strong> extremeweather conditions, park networking,<strong>energy</strong> data acquisition anddiagnostics, and visualization.String combiner technologyString combiner technology <strong>for</strong> collecting,<strong>for</strong>warding and monitoring currents. In addition:protection against surge voltages.PV fi eldStringcombiner boxControl roomInverter stationConnection technologyWith plug-in connector and cablesfeaturing long-term stability, a PV park canbe cabled and connected quickly and easily.Protection <strong>for</strong> the AC currentSurge protection <strong>for</strong> inverters and supply.Power supplyPHOENIX CONTACT 7


Connection technology:connecting and wiringers numerous cabling solutionsthat are perfectly tailored to the requirements of free-standingeasy installation in mind. The DC plug-in connectors <strong>for</strong> fieldwithout special tools. This ensures long-term system availabilityPlug-in connectors<strong>for</strong> assemblyThe innovative spring connection of theDC plug-in connectors enables cables from2.5 to 16 mm2 to be connected reliably andsafely without special tools. This facilitatesparticularly fast on-site assembly.Intelligent connectiontechnology: compact anduser-friendlyYour advantagesconductor cross sections from 2.5 to 16 mm2toolsEasy and reliable mountingInsert the stripped PV conductor Press down on the spring and snap in Tighten screw connection Connection can only be released usinga screwdriver8 PHOENIX CONTACT


Assembled PV cables:Y-distributorsEven more fl exibility in PV cabling:Using Y-distributors, you can easily andinexpensively route adjacent strings to theinverter with just one string cable.They can also be equipped with plug-inconnectors.Customer-specifi c cable lengths are availableon request.Photovoltaic cables:By the meterWith our cable rings, you are supplied withhigh-quality TÜV-certifi ed cables by themeter <strong>for</strong> securely wiring your PV system.DC device plug-in connectorThe DC device plug-in connector is availablepre-assembled on a customer-specifi c basisor as an assembly set <strong>for</strong> user assembly. It issuitable <strong>for</strong> voltages of up to 1500 V andfeatures integrated anti-rotation protection.Consistent connection technology from the PV module to the supplyPV moduleInverterDevice connectionPlug-in connectorsY-distributorPV cablesPlug-in connectors and cables facilitate fi xed or fl exible installation andare suitable <strong>for</strong> a temperature range of -40°C to 85°C.Detailed product in<strong>for</strong>mation on connection technology can be found from page 42PHOENIX CONTACT 9


String combiner box:collection and distributionString combiner boxes collect and distribute string currents,protect the PV modules against surge voltages, and monitor theper<strong>for</strong>mance of the free-standing systems. In this regard, stringcombiner boxes combine numerous electrical and electronicdevices in compact, space-saving housing. Depending on voltageand strength, the fuse, hybrid, and connection terminal blocksthat are used are also available <strong>for</strong> large conductor crosssections.Fuse terminal blocksTerminal blocks <strong>for</strong> protecting individualstrings against reverse currents. The optionalLED signals a blown fuse. By usingappropriate jumpers, the string currents canbe connected and accumulated.Current measuring moduleHybrid terminalblockSurge protection <strong>for</strong>communication cablesSurge protection <strong>for</strong>solar cablesConnection terminal blocks<strong>for</strong> large cross sections in thedirection of the inverterFuse terminal blocksDC disconnect switchPlug-in connections <strong>for</strong>solar cablesCable glands10 PHOENIX CONTACT


String combiner box:monitoringPhotovoltaic systems should achieve maximum <strong>energy</strong> yield fromsolar power in the shortest possible time. It is there<strong>for</strong>e essentialto respond immediately to the failure of individual strings.The PV string current monitoring system from Phoenix Contact,which consists of a communication module and various measuringmodules, enables you to react immediately to malfunctions andpower losses.Current measuring modulesIn a measuring module just 22.5 mm wide,the characteristics of your PV systems aredetermined on a contact-free basis with theaid of Hall sensors and <strong>for</strong>warded to thecommunication module. 4 and 8-channelversions are available.String current monitoringincreases effi ciency in largerphotovoltaic systemsYour advantagesortnecessary4 and 8-channel versionsdesigncontactsThe modular monitoring system consists ofvarious measuring modules <strong>for</strong> current andvoltage measurement and an associatedcommunication module.14 PHOENIX CONTACT


ILC 150 ETHOrder-No.: 2985330HW/FW: 00/100MAC Addr.: 00.A0.48.04.09.C0AUTOMATIONWORXMRESETRUN/PROGPRGLINKSTOPRESET1.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.4Communication modulesThe communication module collects thevalues from the measuring modules and,as a Modbus slave, <strong>for</strong>wards them to yourcentral higher-level control system. It is alsoused to supply the measuring modules in thefi eld. The communication module is simplyintegrated into an existing network as aModbus RTU device.Voltage modulesWith the voltage module you can measureDC voltages of up to 1500 V. The module issuitable <strong>for</strong> both measurements in groundedand insulated PV systems. It is also possibleto use the voltage measurement fl exiblyoutside the monitoring system as a simpleanalog device.Current transducersWith the universal AC/DC currenttrans<strong>for</strong>mers, DC bus cables of up to600 A are monitored. This means that theconductor that is to be monitored does nothave to be interrupted.Monitoring photovoltaic stringsData cables<strong>Solar</strong> cablesCompact controllerMeasuring module <strong>for</strong>current (4 strings)Data cableMeasuring module <strong>for</strong>current (8 strings)PV fi eldMeasuring module <strong>for</strong>current (8 strings)ModbusCommunication module(<strong>for</strong> up to 8 measuring modules)Measurement andcontrol technologyMeasuring module<strong>for</strong> voltageThe measuring module can be used to measure up to eight direct currents and one DC voltage value at thesame time. The complete system enables you to operate eight measuring modules on one communicationmodule. The 2-wire communication cable is used to supply the measuring modules with power. This meansthat you can supply up to eight measuring modules without an additional power supply unit.Detailed product in<strong>for</strong>mation on string current monitoring systems can be found from page 48PHOENIX CONTACT 15


Park management:sensor connection <strong>for</strong> extremeweather conditionsOutdoor PV cabling is constantly exposed to particularconditions: UV radiation, ozone pollution, extreme heat,extreme cold, and sudden changes in temperature. In addition,the cabling frequently needs to withstand vibrations, and shocks.For these extreme conditions, Phoenix Contact offers suitableplug-in connectors, cables, and distributor boxes.Cables <strong>for</strong>outdoor applicationsThe halogen-free control cable is installedoutdoors in direct sunlight. The insulationand sheath materials offer excellentresistance to weather, UV, and wear.Thanks to its outstanding resistance to oil,high degree of fl exibility, and low smoke gasdensity, it is also suitable <strong>for</strong> automationtechnology, machine building and systemsmanufacturing – anywhere and everywhereplagued by particularly harsh ambientconditions.Extreme atmosphericinfl uences – no problem <strong>for</strong>M12 cablingThe right materials <strong>for</strong> harshconditionsThrough the selection of special materials, thecomponents are designed <strong>for</strong> use outdoors.They are resistant to UV, ozone, corrosion, andtemperature. Intensive test methods such as airstorage ensure that the plug-in connectors andcables are suitable <strong>for</strong> controlling solar plants inthe long term without any restrictions.16 PHOENIX CONTACT


87654321ILC 150 ETHOrder-No.: 2985330HW/FW: 00/100MAC Addr.: 00.A0.48.04.09.C0AUTOMATIONWORXMRESETRUN/PROGPRGLINKSTOPRESET1.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.412345678Plug-in connectors<strong>for</strong> assemblyThe plug-in connector knurls are made fromstainless steel and the plastics are resistantto atmospheric infl uences. For reliablecontacting, choose particularly fast insulationdisplacement or screw connections.Plug-in connections made of metal or plasticwith corresponding outdoor propertiesfacilitate the individual adaptation of cablelengths in the fi eld at any point in time.Assembled cablesIn addition to 4, 5, and 8-pos. shielded andunshielded versions, PROFINET and Ethernetcables are available <strong>for</strong> data applications.The materials used in our products, such ascables with a cross-linked special polymerouter sheath and a special extrusion coatingof polypropylene, guarantee a safe plug-inconnection outdoors. In addition, all themetal parts are manufactured from V4A towithstand corrosive atmospheric infl uences.Distributor boxesRobust, fully molded sensor/actuatordistributor boxes with 8 slots are availablewith fi xed master cable or plug-in screwconnection.The distributor boxes have corrosionresistantmetal knurls made from tin-platedzinc die casting and are produced fromUV-resistant plastic.M12 cabling <strong>for</strong> outdoor useRadiation sensorPV fi eldPV trackerDistributor boxWeather stationMeasurement and controltechnology(weather-resistant)CompactcontrollerSuitable components <strong>for</strong> connecting sensors and actuators in yourfree-standing system in all weathers.Detailed product in<strong>for</strong>mation on sensor/actuator cabling can be found from page 50PHOENIX CONTACT 17


Park management:networkingThe network infrastructure components from Phoenix Contactcommunication of the individual network devices.It is also possible to per<strong>for</strong>m maintenance operations on thepreventing unwelcome third party network access.WLAN access pointWith the industrial WLAN access point,Phoenix Contact offers a device <strong>for</strong>wireless communication according to theIEEE 802.11n WLAN standard. Theintegrated cluster management functionenables your WLAN network to be easilyand centrally confi gured and monitored.Network your free-standingsystem quickly and easilywith components fromPhoenix Contact andcreate redundant andfi rewall-protected networks.Your advantagescan be expandedOptimum connection technology<strong>for</strong> fi ber optics18 PHOENIX CONTACT


Park management: acquiring andmonitoring <strong>energy</strong> dataContinual control is the key to efficient PV park management.Phoenix Contact offers standard and customer-specific solutions<strong>for</strong> controlling, processing, and visualizing all aspects of<strong>photovoltaics</strong>. Innovative software products such as libraries <strong>for</strong>functional blocks according to IEC 61131 and drivers <strong>for</strong> dataloggers and interfaces also facilitate adaptation to the increasinglyimportant power supply rules.Compact controllersThe class 100 controllers not only allow youto control the complete system, but also toimplement continuous monitoring.They enable the integration of I/O signalsfrom Modbus devices into the controlprogram via Modbus/TCP. Additionalcontrollers and systems can be connected viathe Ethernet interface.Your advantages ciency of your PV system, thanksto monitoring and acquiring <strong>energy</strong> andper<strong>for</strong>mance data<strong>for</strong> the compact controllers and the wide rangeof functions of the I/O systems.module temperature as well as global radiationinverters20 PHOENIX CONTACT


I/O systemsA wide range of I/O modules and variousfunction terminals suitable <strong>for</strong> all applicationsare available. For example, you can acquiretemperatures and positions with one moduleeach, which can be fl exibly mounted on thePLC.Operator panels and observationdevicesIn conjunction with class 100 compactcontrollers, HMI devices from PhoenixContact are the cost-effective option <strong>for</strong>basic operating and observation tasks in afree-standing system. Various web panelsalso facilitate the individual implementationof user interfaces <strong>for</strong> your park visualization.Energy metersWith the network-capable <strong>energy</strong> meters,you can monitor characteristic electrical databoth centrally and on site. You can there<strong>for</strong>egather all characteristic data relevant toproduction via a compact controller and logit in an SQL database.Monitoring and diagnostics <strong>for</strong> free-standing systemsPV fi eldStringcombiner boxInverterstationPower supplyDC cableAC cableEnergymeterAutomation networkCompact controllerI/O modulesServerOperatorpanelPCEthernetEthernetInternetMobiledeviceEasy programming and control, thanks to standard functional blocks.The status and per<strong>for</strong>mance data can be requested via web panels or web browser.Detailed product in<strong>for</strong>mation on monitoring and diagnosis devices can be found from page 56PHOENIX CONTACT 21


Park management:automation and visualizationUse continuous production data acquisition and datamanagement to enhance the efficiency and yield of yourPV system. To this end, Phoenix Contact enables free-standingsystems to be networked worldwide with automation andvisualization tools. This enables you to acquire and evaluate dataat all times. Redundant systems ensure the availability of thePV systems.Automation and visualizationsolutionsIn solar park management systems, data mustbe transmitted from local on-site stations toa central computer system, where it is saved,analyzed, and displayed. Do you want todisplay and edit this data at the distributedterminals that use web browsers as well asthe control center? If so, Phoenix Contactprovides the perfect solution. This systemsolution is achieved easily with the AXweb+Internet application and PC WORXautomation software. All data can betransmitted via Ethernet or GPRS/EDGE.22 PHOENIX CONTACT


ILC 150 GSM/GPRSOrder-No.: 2916545ILC 150 ETHOrder-No.: 2985330HW/FW: 00/100MAC Addr.: 00.A0.48.04.09.C0AUTOMATIONWORXMRESETSTOPRUN/PROGPRGLINKRESETILC 150 ETHOrder-No.: 2985330HW/FW: 00/100MAC Addr.: 00.A0.48.04.09.C0AUTOMATIONWORXMRESETSTOPRUN/PROGPRGLINKRESETILC 150 ETHOrder-No.: 2985330HW/FW: 00/100MAC Addr.: 00.A0.48.04.09.C0AUTOMATIONWORXMRESETSTOPRUN/PROGPRGLINKRESETLNKMRESETSTOPRUN/PROGACTRESET1.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.41.1 2.11.2 2.21.3 2.31.4 2.4X2 LANX9P1 Stat Mod SigP2 Err Fault InfoPOWERDSLInternetDSLLANPOWERDSLInternetDSLLANX2 LANX9P1 Stat Mod SigP2 Err Fault InfoPLC programmingAll Phoenix Contact controllers can beprogrammed consistently with PC WORXsoftware. It combines programming accordingto IEC 61131, fi eldbus confi guration, andsystem diagnostics.The free PC WORX EXPRESS software issuitable <strong>for</strong> cost-sensitive PV systems withstraight<strong>for</strong>ward requirements. It is reducedto the most important basic functions.Web visualizationWebVisit enables you to easily create userinterfaces <strong>for</strong> the visualization of a PV system.WebVisit facilitates quick and user-friendlyrepresentation of your control variables.Monitor your PV system via a PC using astandard browser or via a web panel. Remotecontrol is also possible with WebVisit.Web-basedmanagement systemAXweb+ is a management system thatdepicts per<strong>for</strong>mance data of one or morePV systems. You retrieve data from theSQL server via freely confi gurable web pages:locally or via the Internet. The integratedassignment of permissions authorizes accessto sensitive data.Wireless transmissionPV fi eldInternet/local networkWEBVISITWeb VisualizationPCCompact controllerwith GSM modemMobile phonerouterLocal networkhttp/httpsCompactcontrollerEthernetport adapterWLANaccess pointServerInternetLAN transmissionInternet/local networkPV fi eldRouter withfi r e w a l lWEBVISITWeb VisualizationX1 WANX1 WANPCX6 Configurationrs2000TC DSL ROUTER X400 A/BOrd.-No: 29 02 709InternetTC DSL ROUTER X400 A/BOrd.-No: 29 02 709DSLmodemX6 Configurationrs2000Local networkhttp/httpsCompact controllerServerInternetDetailed product in<strong>for</strong>mation on software can be found on page 60PHOENIX CONTACT 23


<strong>Solutions</strong> <strong>for</strong> tracking systemsTaking the sunfl ower as an example, photovoltaic tracking systems likewise track thecourse of the sun. In comparison with permanently installed PV systems, trackingsystems there<strong>for</strong>e generate far higher yields.With the compact hybrid motor starters from Phoenix Contact, you can switch andreverse tracking systems safely and reliably. In addition, Phoenix Contact offers acomprehensive range of automation components <strong>for</strong> controlling a tracking park.“Tracking systems generate a large amountof <strong>energy</strong> in a small amount of space – withthe right technology, they function even moreeffi ciently”.24 PHOENIX CONTACT


PV trackerMobile deviceStringcombiner boxControl roomTracking systems always in focusTracking systems track the sun withtechnology from Phoenix Contact.Reliable on-site and remote control andmaintenance of a tracking park is possible.Inverter stationPower supplyPHOENIX CONTACT 25


Tracking systems:trackingThe yield from solar panels can be optimized with the help of asingle or double-axis tracking system. Exact tracking aligns thesolar cells to the sun so that sunlight falls perpendicular to thesolar modules. This guarantees optimum <strong>energy</strong> generation.Continually monitoring the system status is of major importancein this regard. With software and hardware from PhoenixContact, you can implement an effi cient and reliable monitoringsystem <strong>for</strong> your tracking park.Compact controllers <strong>for</strong> drivecontrolCompact controllers with an integratedModbus interface are ideal <strong>for</strong> controllingtracking systems. Step motor drivers andfrequency inverters can be connecteddirectly without any additional modules.Analog or incremental input channels areavailable <strong>for</strong> position detection.Switch and reverse motorsquickly and reliably withcompact hybrid motorstarters.Your advantagesfunctional block librariesEthernet or a mobile phone networkPV modules by means of solar altitudecalculationsReliable technology fromPhoenix Contact: ideal <strong>for</strong>durable application intracking systems.26 PHOENIX CONTACT


Compact controllers with modemHybrid motor starterMobile phone routerThanks to an integrated GSM/GPRS modem,these compact controllers are the perfectsolution <strong>for</strong> remotely controlling andmaintaining your PV tracking systems.The PLC acquires operating data and sendserror messages and system in<strong>for</strong>mation.To track PV modules, the hybrid motorstarter offers four functions: <strong>for</strong>wardrunning, reverse running, motor protection,and emergency stop. This motor starterhas signifi cantly longer service life thanmechanical contactors, saves space, and canbe quickly wired.The industrial 3G mobile phone routerenables you to access your systemsworldwide via high-speed connections.The router supports UMTS/HSPA in the3G network and features GPRS/EDGEfallback. Firewall and VPN provide reliableprotection <strong>for</strong> your tracking system.Control and regulate tracking systems efficientlyPV trackerHybridmotor starterMotorPCMobiledeviceProximitysensorCompactcontroller withGSM modemMobile phonerouterServerEthernetIncrease the yield from your PV system by systematically tracking PV modules.Detailed product in<strong>for</strong>mation on hybrid motor starters can be found on page 60PHOENIX CONTACT 27


<strong>Solutions</strong> <strong>for</strong> rooftop systemsLarge, slightly slanted roof surface areas provide ideal conditions <strong>for</strong> the profi tabledeployment of <strong>photovoltaics</strong>. As a result of declining module prices and increasing <strong>energy</strong>costs, PV systems on private, commercial, and public buildings are becoming increasinglyattractive, even without state subsidies. For the purpose of providing comprehensive andpermanent protection against all manner of lightning currents and surge voltages,Phoenix Contact offers a wide range of surge protection products.“PV rooftop systems use available spaces –why shouldn't the technology <strong>for</strong> these systemsbe equally as space saving?”28 PHOENIX CONTACT


Industrialcompany buildingAgriculturalproduction buildingPublicbuildingInverter stationSurge protectionReliably protect all types of PV rooftopsystems against surge voltagesPower supplyPHOENIX CONTACT 29


surge protectionIt is not always a direct lightnincauses surge voltage damage. Surge voltages can also be coupledPhoenix Contact offers reliable system solutions that protectThe surge couplings are thereby diverted straight to the groundpotential, protecting the inverters and other sensitive devicesagainst surge voltage.DC type 1/2 lightning/surgeprotectionThe PV-SET 1000 DC protects the singlephaseinverter in your single-string system onthe DC voltage side. One or two PV sets arenecessary, depending on cable lengths.Protect your PV rooftop systemsagainst surge voltages triggeredby lightning strikesYour advantagesall sets are installed in housing which isprotected against dust and jet water (IP65)the PV setssystemCompact and fully pre-assembled:reliable surge protection <strong>for</strong> yourPV system30 PHOENIX CONTACT


VAL-MS-T1/T2 VAL-MS-T1/T2 VAL-MS-T1/T21000DC-PV ST 1000DC-PV ST 1000DC-PV STU p : 1,8 kV U p : 1,8 kV U p : 1,8 kVI n : 15 kA PV T2 I n : 15 kA PV T2 I n : 15 kA PV T2I lmp : 5 kA PV T1 I lmp : 5 kA PV T1 I lmp : 5 kA PV T1I max : 40 kA I max : 40 kA I max : 40 kAC-115C-103C-10328 01 16 228 01 16 2L+ L-28 01 16 2VAL-MS-T1/T2VAL-MS-T1/T2VAL-MS-T1/T21000DC-PV ST1000DC-PV ST1000DC-PV STU p : 1,8 kVU p : 1,8 kVU p : 1,8 kVI n: 15 kA PV T2I n : 15 kA PV T2I n: 15 kA PV T2I lmp: 5 kA PV T1I lmp: 5 kA PV T1I lmp: 5 kA PV T1I max : 40 kAI max : 40 kAI max : 40 kAC-115C-103C-10328 01 16 2 28 01 16 228 01 16 2L+ L-VAL-MS-T1/T2VAL-MS-T1/T2VAL-MS-T1/T21000DC-PV ST1000DC-PV ST 1000DC-PV STU p : 1,8 kVU p : 1,8 kVU p : 1,8 kVI n: 15 kA PV T2 I n: 15 kA PV T2 I n : 15 kA PV T2I lmp: 5 kA PV T1 I lmp: 5 kA PV T1I lmp: 5 kA PV T1I max : 40 kA I max : 40 kA I max : 40 kAC-115C-103C-10328 01 16 228 01 16 228 01 16 2L+ L-VAL-MS-T1/T2 VAL-MS-T1/T2 VAL-MS-T1/T21000DC-PV ST 1000DC-PV ST 1000DC-PV STU p : 1,8 kV U p : 1,8 kV U p : 1,8 kVI n : 15 kA PV T2 I n : 15 kA PV T2 I n : 15 kA PV T2I lmp : 5 kA PV T1 I lmp : 5 kA PV T1 I lmp : 5 kA PV T1I max : 40 kA I max : 40 kA I max : 40 kAC-115C-103C-10328 01 16 2 28 01 16 2 28 01 16 2L+ L-VAL-MS-T1/T2 VAL-MS-T1/T2 VAL-MS-T1/T21000DC-PV ST 1000DC-PV ST 1000DC-PV STU p : 1,8 kV U p : 1,8 kV U p : 1,8 kVI n : 15 kA PV T2 I n : 15 kA PV T2 I n : 15 kA PV T2I lmp : 5 kA PV T1 I lmp : 5 kA PV T1 I lmp : 5 kA PV T1I max : 40 kA I max : 40 kA I max : 40 kAC-115C-103C-10328 01 16 2 28 01 16 2 28 01 16 2L+ L-VAL-MS-T1/T2 VAL-MS-T1/T2 VAL-MS-T1/T21000DC-PV ST 1000DC-PV ST 1000DC-PV STU p : 1,8 kV U p : 1,8 kV U p : 1,8 kVI n : 15 kA PV T2 I n : 15 kA PV T2 I n : 15 kA PV T2I lmp : 5 kA PV T1 I lmp : 5 kA PV T1 I lmp : 5 kA PV T1I max : 40 kA I max : 40 kA I max : 40 kAC-115C-103C-10328 01 16 2 28 01 16 2 28 01 16 2L+ L-VAL - MS1000DCUOCmax: 1000VDCVAL-MSVAL-MSVAL-MS1000PV ST1000PV ST 1000PV STU p: 2,5 kVU p : 2,5 kVU p: 2,5 kVI n : 15 kAI n: 15 kAI n: 15 kAI max: 30 kAI max: 30 kAI max: 30 kAII/C/ T2II/C/ T2II/C/ T2W-139W-139W-13928 05 18 528 05 18 528 05 18 5L+L-VAL-MSF-MS320 ST12 STU C: 335V ACU C: 260V ACU p: 1,5 kAU p: 1,5 kAI n: 20 kA I n: 20 kAI max: 40 kAI max: 40 kAII/C/ T2II/C/ T2A-337B-10128 38 84 328 17 99 0LNVAL - MS13571000DCUOCmax: 1000VDCONVAL-MSVAL-MSVAL-MS1000PV ST 1000PV ST1000PV STOFFU p: 2,5 kVU p : 2,5 kV U p: 2,5 kVI n: 15 kA I n: 15 kAI n: 15 kAI max: 30 kAI max: 30 kAI max: 30 kAII/C/ T2II/C/ T2II/C/ T2W-139W-139W-13928 05 18 528 05 18 528 05 18 5L+L-8 6 4 2VAL - MS1000DCUOCmax: 1000VDCVAL-MSVAL-MSVAL-MS1000PV ST1000PV ST1000PV STU p : 2,5 kVU p: 2,5 kVU p: 2,5 kVI n : 15 kAI n: 15 kAI n: 15 kAI max: 30 kAI max: 30 kAI max: 30 kAII/C/ T2II/C/ T2II/C/ T2W-139W-139W-13928 05 18 528 05 18 528 05 18 5L+L-VAL-MSF-MS320 ST12 STU C: 335V ACU C: 260V ACU p: 1,5 kAU p: 1,5 kAI n: 20 kAI n: 20 kAI max: 40 kAI max: 40 kAII/C/ T2II/C/ T2A-337B-10128 38 84 328 17 99 0LNDC lightning/surge protection <strong>for</strong>type 1/2 multi-string systemsWith the PV sets <strong>for</strong> multi-string PV systems,each individual MPP tracker of an inverter isprotected against surge voltage damage.Versions are available <strong>for</strong> inverters with twoor three MPP trackers.Surge protectionType 2 DC/ACInverters should be protected against surgevoltages on both the DC and AC voltageside. The PV-SET 1000 DC/AC combinesboth DC and AC side inverter protection.DC surge protection <strong>for</strong>5 type 2 stringsThe prewired PV-SET 5ST/600 DCaccommodates up to fi ve PV strings with astring voltage of 600 V DC. A generatordisconnect provides additional safety.Multi-string system Combined DC/AC protection 5-string systemPV panelPV panelPV panelPV-SET1000 DCPV-SET1000 DCPV-SET5ST/600 DCPV-SET <strong>for</strong>multi-stringsystemsInverterInverterInverterPV-SET1000 DC/ACPV-SET1000 DC/ACSurge protection <strong>for</strong> 1 to 4 strings.Alternatively available with protection<strong>for</strong> inverters with up to 3 MPP trackers.Combined DC/AC protection <strong>for</strong>inverters.Surge protection <strong>for</strong> 5 strings.Alternatively available with combinedAC/DC protection.If the cables between solar panel and inverter are longer than 10 m,a PV set should be installed directly at the solar panel.Detailed product in<strong>for</strong>mation on surge protection sets can be found on page 61PHOENIX CONTACT 31


<strong>Solutions</strong> <strong>for</strong> building integrationAn increasing number of building contractors, architects, engineers, and specialistplanners are opting <strong>for</strong> building-integrated <strong>photovoltaics</strong> (BIPV). It is the combination ofaesthetics, CO2-free power generation, and weather protection that renders solarmodules on facades and roofs such an attractive proposition. They also enable theavailable space on the building to be used more effi ciently.“Set not only power supply but alsobuilding design trends.”32 PHOENIX CONTACT


Industrial buildingwith facade panelsBuilding with partially transparentwindow panelsPublic buildingwith roof integrationPower supplyConnecting and combiningThe Phoenix Contact miniature connectionsystem fulfi lls the special requirements that BIPVimposes on connection technology.PHOENIX CONTACT 33


Building integration:connecting and combiningAbsorb solar <strong>energy</strong> not only from the roof of a building, butfrom its entire surface. Phoenix Contact has developed a newDC connection system in miniature <strong>for</strong>mat <strong>for</strong> this trend in<strong>energy</strong> generation using <strong>photovoltaics</strong>. This allows you toefficiently use the facade of a building to generate <strong>energy</strong>. Theprevailing, usually tight, spaces impose special connectiontechnology requirements <strong>for</strong> building-integrated PV modules.The Phoenix Contact miniature connection system meets theserequirements perfectly.The miniature DC plug-inconnectors have a diameterof just 11 mm and can beconnected without a specialtoolYour advantages:2.5 mm2technologyModule junction box:quick and easy mounting1. Position the module junction boxabove the ribbon.2. Remove the adhesive strip andposition the module junction boxes onthe edge of the glass.3. Insert the ribbon in the spring case,snap in the spring, and close theconnection area with the cover.4. Fill each of the module junction boxesin turn with sealant using the specialopening.34 PHOENIX CONTACT


PV-DB-2,5Single-positionmodule junction boxesOne module junction box is used perposition. Both module junction boxes areintegrated into the facade module andsubsequently potted.Their adaptable width enables modulejunction boxes to be integrated very easily.Miniature DC plug-in connectors<strong>for</strong> assemblyThe compact design of the plug-inconnectors enables concealed installationbehind the PV modules or direct installationwithin the facade profi le.Assembly is quick and easy and requires noadditional special tools.CompactDC string diodesReturn currents can occur in PV modules as aresult of shading. The stable housing and fl atdesign of the DC string diode ensure the safefl ow of current between the facade modules.It protects the modules against reversecurrents of up to 5 A at 1000 V according toIEC. The maximum reverse voltage is 2200 V.Connection technology <strong>for</strong> BIPVMiniature DCplug-in connectorOne-piecemodule junction boxCompactDC string diodePV-DB-2,5From the junction box to the string diode, all the componentsare hidden from view in the building facade.<strong>Solar</strong> cablesDetailed product in<strong>for</strong>mation on BIPV connection technology can be found on page 62PHOENIX CONTACT 35


<strong>Solutions</strong> <strong>for</strong> autonomous power supplyPhoenix Contact solar systems supply your external stations independently of the powergrid – even on short, dark winter days. The systems are ideal <strong>for</strong> supplying weatherstations or parking meters with power. Combined with wireless technology, they openup new possibilities <strong>for</strong> covering remote and poorly accessible system parts.“Autonomous power supply isopening up new possibilities <strong>for</strong>your distributed automationsolutions.”36 PHOENIX CONTACT


Your advantages:<strong>energy</strong> consumptionadjusted in increments<strong>Solar</strong> systemsComplete solar systems with 100 and 200 Wp are available <strong>for</strong>worldwide operation. When exposed to sunlight, the battery ischarged via the solar panel and charge controller. The charge controlleris responsible <strong>for</strong> battery charge management and protects the batteryagainst total discharge. Connected loads – such as wireless modules –are supplied with the relevant system voltage from the solar system.Autonomous power supply in the field<strong>Solar</strong> panelWireless transmission system(optional)Surge protectionWireless antenna(optional)<strong>Solar</strong> panelbracketControl cabinet withprewired charge controller<strong>Solar</strong> batteriesPossible areas of application: – Level monitoring <strong>for</strong> rainwaterreservoirs– Level measurement <strong>for</strong> rivers andreservoirs – Oil and gas pipeline monitoring – Repeater applications, e.g., bypassingobstacles and covering long distances– Monitoring weather data– Supplying power <strong>for</strong> communicationstechnologyCablingDetailed product in<strong>for</strong>mation on autonomous power supply can be found on page 63PHOENIX CONTACT 37


AccessoriesPhoenix Contact offers you a wide range ofproducts <strong>for</strong> all your PV system operations: e.g.,marking systems and materials enabling yourPV system wiring to be marked transparently andefficiently. In addition, high-quality and sophisticatedtools are available <strong>for</strong> fast and safe installation.38 PHOENIX CONTACT


Crimping toolCutting toolStripping toolThe right tool <strong>for</strong> the installation ofPV systemsCutting, stripping, crimping, and screwing – Phoenix Contactoffers a high-quality hand tool <strong>for</strong> every application.Avoid unnecessary searching by storing your tools in a clearway: with the <strong>Solar</strong> toolset, the right tools are clearlyarranged and always to hand, particularly <strong>for</strong> on-siteoperations.<strong>Solar</strong> tool kitEasy and professional markingEnsure fast startups and short downtimesin the event of maintenance operations byclearly and permanently marking all theelements of your electrical photovoltaicinstallation.Phoenix Contact offers a tailor-mademarking system: mark terminal blocks,cables, devices, and equipment withweather and UV-resistant markingmaterials.Terminal markingCable and conductor markingDevice markingThermal transfer printer <strong>for</strong>material off the rollThermal transfer printer <strong>for</strong> cardsDetailed product in<strong>for</strong>mation on accessories can be found on page 63PHOENIX CONTACT 39


Service and supportOur specialists are always on hand to help you plan, confi gure,and implement your photovoltaic solution. Invariably boastingvast technical expertise, they bear in mind your specificrequirements.Together with our specialists, you will always find the idealsolution to meet your requirements.40 PHOENIX CONTACT


EngineeringDo you need a customized solution?We can offer you the necessarytechnological expertise, combined withvast experience in many industries.Our expert project management teamwill guide you through all the importantphases of your project. Together withyou, we will arrange the necessaryservices and handle the subtasks duringthe implementation phase.ServiceOur service teams stand out thanks totheir focused expertise, years ofpractical experience, and maximumdegree of fl exibility. Our servicenetwork is on hand to assist you duringinstallation, startup, and operation,even in the most remote corners ofthe world.Training and workshopsThanks to intensive contact with ourcustomers and years of on-siteexperience, we have developed aqualifi cation concept whereby we canspecify employee qualifi cations so as tomeet your individual requirements.We will offer you the appropriateservice depending on the project phase,target group, and prior knowledge.We provide support <strong>for</strong> thefollowing: To learn more about our trainingcourses and workshops and <strong>for</strong> directassistance with your <strong>photovoltaics</strong>pecific issues, please feel free toapproach your local contact person.We offer seminars and workshopson various topics: systems Your personal contact person will provide telephonesupport and, in the event of a malfunction, organizeimmediate delivery of replacement parts or on-siteservice.PHOENIX CONTACT 41


Selection tables andtechnical dataDC connection technology <strong>for</strong> devicesSUNCLIXDC device plug-in connectorsWith 130 mm litz wire; otherlengths are available on requestType Order No. Pin(-) 1805148Socket (+) 1805135Pin(-) 1805164Socket (+) 1805151Pin (-) 1805180Socket (+) 1805177Cross section 2.5 mm2 4 mm2 6 mm2Rated voltage 1500 V 1500 V 1500 VNominal current Maximum 27.5 A Maximum 40 A Maximum 40 ADegree of protectionIP65/IP66/IP68(24 h/2 m)IP65/IP66/ IP68(24 h/2 m)IP65/IP66/ IP68(24 h/2 m)Properties Temperature range: -40°C to +85°C, VDE-certifi ed according to DIN EN 50521SUNCLIXDC device plug-in connectorsFor user assemblyDescription Plastic housing Contacts <strong>for</strong> crimp connection,1500 V/2.5 – 4 mm2Contacts <strong>for</strong> crimp connection,1500 V/6 mm2Type Order No. Pin (-) 1704925Socket (+) 1704926Pin (-) 1704927Socket (+) 1704930Pin (-) 1704928Socket (+) 1704931Cross section – 2.5 – 4 mm2 6 mm2Rated voltage – 1500 V 1500 VNominal current – Maximum 40 A Maximum 40 APropertiesTemperature range: -40°C to +85°C, VDE-certifi cation according to DIN EN 50521 in progressAccessoriesType Order No. Fastening nut 177588042 PHOENIX CONTACT


DC connection technology <strong>for</strong> PV modules and field cablingSUNCLIXDC plug-in connectorsCan be assembledType Order No. Pin (-) 1774687Socket (+) 1774674Pin (-) 1789834Socket (+) 1789821Pin (-) 1790797Socket (+) 1790784Cross section 2.5 – 6 mm2 2.5 – 6 mm2 6 – 16 mm2Rated voltage 1100 V 1500 V 1500 VNominal current Maximum 40 A Maximum 40 A Maximum 65 ADegree of protection IP66/IP68 (24 h/2 m) IP66/IP68 (24 h/2 m) IP66/IP68 (24 h/2 m)Ambient temperature(operation)-40°C to +85°C -40°C to +85°C -40°C to +85°CPropertiesVDE-certifi ed according to DIN EN 50521, class II protectionSUNCLIXDC accessoriesDescriptionY-distributor DC test plug <strong>Solar</strong> cableConnection set with branch line<strong>for</strong> fast parallel interconnectionof photovoltaic modules.Cable length: 120 mmTest plug with tool-free release<strong>for</strong> test applications with highinsertion/withdrawal cyclesCable length: 1500 mmTin-plated single litz wires, suitable <strong>for</strong> permanent and fl exibleinstallation; insulating and sheath material off ers excellent resistanceto weather, UV, and wear; TÜV and VDE-certifi ed PV1-F cableCross section 100 m ring 500 m drum 1000 m drumPin to 2 x socket (-/++)Socket to 2 x pin (+/--)Pin to 2 x socket (-/++)Socket to 2 x pin (+/--)4 mm2 17950194 mm2 17950226 mm2 17877266 mm2 1787739Pin (-) 1780464Socket (+) 17804512.5 mm24 mm26 mm210 mm2145950914595111459524145953714595401787700178771314595531459566145957914595821459595Cross section 4 – 6 mm2 10 mm2 –Rated voltage 1100 V 1100 V –Nominal current Maximum 40 A Maximum 40 A –Degree of protection IP66/IP68 (24 h/2 m) IP20 –Ambient temperature(operation)-40°C to +85°C -20°C to +55°C -40°C to +90°CAccessoriesType Order No. Protective cap 1785430 Filler plug 1775631PHOENIX CONTACT 43


Terminal blocks – fuses – accessoriesTypeOrder No. Type/blue Order No.Conductor connection[mm2/AWG]Voltage[V]Current[A]CoverPush-in connection terminal blocksFeed-through terminal blocks with two connectionsPT 6 3211813 PT 6 BU 3211819 0.5 - 10/20 - 8 1000/600 41 3212011PT 10 3212120 PT 10 BU 3212123 0.5 - 16/20 - 6 1000/600 57 3212047PT 16 N 3212138 PT 16 N BU 3212142 0.5 - 25/20 - 4 1000/– 76 3212060PTPOWER 95 3260100 PTPOWER 95 BU 3260103 25 - 95/4 - 3/0 1500/– 232 –Modular terminal blocks (feed-through terminal blocks) with three connectionsPT 6-TWIN 3211929 PT 6-TWIN BU 3211985 0.5 - 10/20 - 8 1000/600 41 3211508PT 10-TWIN 3208746 PT 10-TWIN BU 3208747 0.5 - 16/20 - 6 1000/600 57 3208748PT 16 TWIN N 3208760 PT 16 TWIN BU 3208773 0.5 - 25/20 - 4 1000/– 76 –Modular terminal blocks (feed-through terminal blocks) with four connectionsPT 6-QUATTRO 3212934 PT 6-QUATTRO BU 3212937 0.5 - 10/20 - 8 1000/600 41 3212963Disconnect terminal blockPTME 6 HV 3035696 PTME 6 HV BU 3035695 0.5 - 10/20 - 8 1000/– 30 3034426Diode terminal blockPTME 6-DIO/L-R HV 3035697 – 0.5 - 10/20 - 8 1000*/– 5 3034426PTME 6-DIO/R-L HV 3035698 – 0.5 - 10/20 - 8 1000*/– 5 3034426DP-STMED6 3036590 A spacer plate of similar shape ensures suffi cient spacing between two neighboring diode terminal blocksSpring-cage connection terminal blocksFeed-through terminal blocks with two connectionsST 6 3031487 ST 6 BU 3031490 0.2 - 10/24 - 8 1000/600 52 3030433ST 10 3036110 ST 10 BU 3036123 0.2 - 16/24 - 6 1000/600 65 3036644ST 16 3036149 ST 16 BU 3036149 0.2 - 25/24 - 4 1000/600 90 3036657ST 35 3036178 ST 35 BU 3036181 2.5 - 35/14 - 2 1000/600 125 –Modular terminal blocks (feed-through terminal blocks) with three connectionsST 6-TWIN 3036466 ST 6-TWIN BU 3036479 0.2 - 10/24 - 8 1000/600 52 3036767ST 10-TWIN 3035288 ST 10-TWIN BU 3035292 0.2 - 16/24 - 6 1000/600 70 3035288ST 16-TWIN 3035328 ST 16-TWIN BU 3035331 0.2 - 25/24 - 4 1000/600 90 3035357Potential terminal blocks with one screw connection and four spring-cage connectionsSTU 35/ 4X10 3033126 STU 35/ 4X10 BU 30332101 x 0.2 - 50/24 - 1/04 x 0.2 - 10/24 - 81000/600 125 –Disconnect terminal blockSTME 6 HV 3035693 STME 6 HV BU 3035694 0.2 - 10/24 - 8 1000/– 30 3034426Diode terminal blockSTME 6-DIO/L-R HV 3035691 – 0.2 - 10/24 - 8 1000*/– 5 3034426STME 6-DIO/R-L HV 3035692 – 0.2 - 10/24 - 8 1000*/– 5 3034426DP-STMED6 3035690 A spacer plate of similar shape ensures suffi cient spacing between two neighboring diode terminal blocksScrew connection terminal blocksFeed-through terminal blocks with two connectionsUT 2.5 3044076 UT 2.5 BU 3044089 0.14 - 4/26 - 12 1000/600 32 3047028UT 4 3044102 UT 4 BU 3044115 0.14 - 6/26 - 10 1000/600 41 3047028UT 6 3044131 UT 6 BU 3044144 0.2 - 10/24 - 8 1000/600 57 3047028UT 10 3044160 UT 10 BU 3044188 0.5 - 16/20 - 6 1000/600 76 3047028UT 16 3044199 UT 16 BU 3044209 1.5 - 25/16 - 4 1000/600 101 3047026UT 35 3044225 UT 35 BU 3044238 1.5 - 50/16 - 1/0 1000/600 150 –UKH 50 3009118 UKH 50 BU 3009105 16 - 70/6 - 2/0 1000/600 150 –UKH 70 3213140 UKH 70 BU 3244601 16-95/4-3/0 1000/1000 192 –UKH 95 3010013 UKH 95 BU 3010136 25 - 95/4 - 3/0 1000/600 232 –UKH 150 3010110 UKH 150 BU 3010123 35 - 150/2 - 300 1000/600 309 –UKH 240 3010217 UKH 240 BU 0711852 70 - 240/2/0 - 500 1000/600 415 –UHSK/S 2000 0704076 – 0.5 - 10/20 - 8 2000/1000 41 0704021Disconnect terminal blockUT 6-T-HV 3070134 – 0.2 - 10/24 - 8 1000/– 57 3070147UT 6-T-HV P/P 3070121 – 0.2 - 10/24 - 8 1000/– 57 3070147Fuse terminal blocksFuse insert2 A 4 AUK 10,3-HESI 1000 V 3211236 – 1.5 - 25/16 - 4 1000/600 3061295 3061305UK 10,3-HESI 1500 V 3062760 – 1.5 - 25/16 - 4 1500/– 3062766 306276744 PHOENIX CONTACT


Jumpers2-pos. 3-pos. 4-pos. 5-pos. 10-pos.Markingcenter grooveLateral and center groove3030284 3030297 3030307 3030310 3030323 0828740 08287483005947 3030297 3030307 3030310 3030323 0829142 08292043005950 3030886 – – – 0829144 08292143260157 3260160 – – – 0829146 –3030284 3030297 3030307 3030310 3030323 0828740 08287483005947 3030297 3030307 3030310 3030323 0829142 08292043005950 3030886 – – – 0829144 08292143030284 3030297 3030307 3030310 3030323 0828740 08287483030284 3030297 3030307 3030310 3030323 0828740 08287483030284 3030297 3030307 3030310 3030323 0828740 08287483030284 3030297 3030307 3030310 3030323 0828740 08287483030284 3030297 3030307 3030310 3030323 0828740 08287483005947 – – – – 0829142 08292043005950 – – – – 0829144 08292143005963 – – – – 0829146 08292183030284 3030297 3030307 3030310 3030323 0828740 08287483005947 – – – – 0829142 08292043005950 – – – – 0829144 08292143030284 3030297 3030307 3030310 3030323 0828740 08287483030284 3030297 3030307 3030310 3030323 0828740 08287483030284 3030297 3030307 3030310 3030323 0828740 8287483030284 3030297 3030307 3030310 3030323 0828740 8287483030161 3030174 3030187 3030190 3030213 – 08287343030336 3030242 3030255 3030349 3030271 – 08287363030284 3030297 3030307 3030310 3030323 – 08287403005947 – – – – – 08291423005950 – – – – – 08291443005963 – – – – – 08291460201346 0201317 – – – – 08291423213195 3213205 – – – – 08291420201362 0201375 – – – – 08291420201388 0201391 – – – – 08291420201401 0201414 – – – – 0829142– – – – 203276 – 08291423030284 3030297 3030307 3030310 3030323 – 08287403030284 3030297 3030307 3030310 3030323 – 08287406 A 8 A 10 A 12 A 16 A 20 AJumpers56-pos.Markingcenter groove3061318 3061321 3061334 3061347 3061350 3061363 3009299 08292043062768 3062769 3062770 3062771 3062772 3062773 3062775 –* 1000 V reverse voltagePHOENIX CONTACT 45


Surge protection <strong>for</strong> DC and AC voltagesSurge protection <strong>for</strong> theDC side up to 1000 V DCStandards/regulations:DIN EN 61643-11,IEC 61643-1, IEC 60364-7-712,EN 50539-11, UL 1449, 3 rdedition, and KEMA-KEURType Order No. VAL-MS-T1/T2 1000DC-PV/2+V-FM2801161VAL-MS-T1/T2 1000DC-PV/2+V2801160VAL-MS-T1/T2 600DC-PV/2+V-FM2801164VAL-MS-T1/T2 600DC-PV/2+V2801163Number of positions 3 3 3 3Status message Optical, remote indication contact Optical Optical, remote indication contact OpticalMaximum continuous voltage UCPV 1050 V DC 1050 V DC 720 V DC 720 V DCISCPV short circuit stability 300 A 300 A 300 A 300 AProtection level U P(L+) - (L-) ≤ 3.5 kV ≤ 3.5 kV ≤ 2.6 kV ≤ 2.6 kVProtection level U P(L+/L-) - PE ≤ 3.5 kV ≤ 3.5 kV ≤ 2.6 kV ≤ 2.6 kVResidual voltage (L+) - (L-) ≤ 2.9 kV (at 5 kA) ≤ 2.9 kV (at 5 kA) ≤ 2 kV (at 5 kA) ≤ 2 kV (at 5 kA)Residual voltage (L+/L-) - PE ≤ 2.9 kV (at 5 kA) ≤ 2.9 kV (at 5 kA) ≤ 2 kV (at 5 kA) ≤ 2 kV (at 5 kA)Surge protection <strong>for</strong> theDC side up to 1000 V DCStandards/regulations:DIN EN 61643-11,IEC 61643-1, IEC 60364-7-712,EN 50539-11, UL 1449, 3 rdedition, and KEMA-KEURType Order No. VAL-MS 1000DC-PV/2+V-FM2800627VAL-MS 1000DC-PV/2+V2800628VAL-MS 600DC-PV/2+V-FM2800641VAL-MS 600DC-PV/2+V2800642Number of positions 3 3 3 3Status message Optical, remote indication contact Optical Optical, remote indication contact OpticalMaximum continuous voltage UCPV 1170 V DC 1170 V DC 800 V DC 800 V DCISCPV short circuit stability 300 A 300 A 300 A 300 AProtection level U P(L+) - (L-) ≤ 3.7 kV ≤ 3.7 kV ≤ 2.7 kV ≤ 2.7 kVProtection level U P(L+/L-) - PE ≤ 3.7 kV ≤ 3.7 kV ≤ 2.7 kV ≤ 2.7 kVResidual voltage (L+) - (L-) ≤ 3.1 kV (at 5 kA) ≤ 3.1 kV (at 5 kA) ≤ 2.2 kV (at 5 kA) ≤ 2.2 kV (at 5 kA)Residual voltage (L+/L-) - PE ≤ 3.1 kV (at 5 kA) ≤ 3.1 kV (at 5 kA) ≤ 2.2 kV (at 5 kA) ≤ 2.2 kV (at 5 kA)Surge protection <strong>for</strong> theAC sideType 1 lightning arresterType 2 surge arresterVALVETRAB compactType Order No. FLT-CP-PLUS-3S-350 2882640 FLT-CP-3S-350 2859712 FLT-CP-1S-350 2859738 VAL-3S-350 2859521IEC-category/EN type I/T1 I+II/T1+T2 I+II/T1+T2 II/T2Lightning Protection Level I/T1 I III - IV –Nominal voltage U N 240/415 V AC (50/60 Hz) 240/415 V AC (50/60 Hz) 240/415 V AC (50/60 Hz) 240/415 V AC (50/60 Hz)Maximum continuous voltageU C(L-N)350 V AC (50/60 Hz) 350 V AC (50/60 Hz) 350 V AC (50/60 Hz) 350 V AC (50/60 Hz)Lightning test current I imp(10/350) μs 100 kA 100 kA 50 kA –Nominal discharge surge current 25 kA (per channel) 25 kA (per channel) 25 kA 20 kA (per channel)Protection level U P ≤ 1.5 kV ≤ 1.5 kV 1.5 kV ≤ 1.4 kVMaximum backup fuseaccording to IEC 61643-1315 A gL/gG 315 A gL/gG 315 A gL/gG 125 A gL/gG46 PHOENIX CONTACT


Surge protection <strong>for</strong> AC voltages, in<strong>for</strong>mation technology, and telecommunicationsBLOCKTRABFor devices with optical oracoustic signaling.DATATRABFor effective surge protectionat network speeds of up to10 Gbps.Type Order No. BT-1S-230AC/A 2803409BT-1S-230AC/O 2800625IEC category/EN typeIII/T3Nominal voltage UN/protection level UpMaximum continuous voltage UC230 V AC/≤ 1.2 kV (L-N)275 V ACDT-LAN-CAT.6+ 2881007 DT-UFB-485/BS 2920612 DT-TELE-RJ45 2882925(incl. PoE) – 100Base-T– 1000Base-TDT-UFB-V24/S-9-SBK0– 10GBase-T280306902MNominal discharge surgecurrent (8/20) μsMaximum backup fuseaccording to IEC 61643-1In3 kA16 A (gL/C)DT-UFB-V24/S-SB-SET2803072PLUGTRABTwo-part surge protectiondesigned with plug-inarresters <strong>for</strong> protectingsignal interfaces of actuatorsand sensorsPlug Order No. PT 5-HF-3DC-ST 2838775 PT 5-HF-12DC-ST 2858043 PT 2X2-24DC-ST 2838228 PT 1X2-24DC/FM-ST 2920078+ Base element,PT 2X2+F-BE 2839224 PT 1X2+F-BE 2856126 PT 2X2+F-BE 2839224 PT 1X2+F-BE/FM 2920023indirect grounding+ Base element,direct grounding– – PT 2X2-BE 2839208 PT 1X2-BE/FM 29200100(4) – 20 mAcurrent loop0(4) – 20 mAcurrent loopCOAXTRABArresters <strong>for</strong> transceiversystemsAccessoriesMounting bracket <strong>for</strong>Type Order No. CN-UB-280DC-SB 2818148 CN-UB-280DC-BB 2818150 CN-UB/MP 2818135 CN-UB/MP-90DEG-50 2803137()with N connector()with N connectorMounting plate <strong>for</strong>attachmentattachmentPHOENIX CONTACT 47


Current transducerCurrent trans<strong>for</strong>mersup to 300 AOutput signal 0 … 10 VType Order No. MCR-SL-CUC-100-U 2308108 MCR-SL-CUC-200-U 2308205 MCR-SL-CUC-300-U 2308302Current measurement [A] 0 … 100 0 … 200 0 … 300Frequency ranges [HZ] DC; 20 … 6000 DC; 20 … 6000 DC; 20 … 6000Connection method Through connection 32 mm Ø Through connection 32 mm Ø Through connection 32 mm ØOutput signal 0 … 10 V 0 … 10 V 0 … 10 VLoad < 300 Ω < 300 Ω < 300 ΩSupply voltage 20 … 30 V DC 20 … 30 V DC 20 … 30 V DCTest voltage: input/output 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min.Test voltage: input/supply 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min.Ambient temperature [°C] -40 to +65 -40 to +65 -40 to +65Current trans<strong>for</strong>mersup to 600 AOutput signal 4 … 20 mAType Order No. MCR-SL-CUC-100-I 2308027 MCR-SL-CUC-200-I 2308030 MCR-SL-CUC-300-I 2308043Current measurement [A] 0 … 100 0 … 200 0 … 300Frequency ranges [HZ] DC; 20 … 6000 DC; 20 … 6000 DC; 20 … 6000Connection method Through connection 32 mm Ø Through connection 32 mm Ø Through connection 32 mm ØOutput signal 4…20 mA 4…20 mA 4…20 mALoad < 300 Ω < 300 Ω < 300 ΩSupply voltage 20 … 30 V DC 20 … 30 V DC 20 … 30 V DCTest voltage: input/output 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min.Test voltage: input/supply 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min.Ambient temperature [°C] -40 to +65 -40 to +65 -40 to +65Current trans<strong>for</strong>mersup to 600 AOutput signal 4 … 20 mAType Order No. MCR-SL-CUC-400-I 2308072 MCR-SL-CUC-500-I 2308085 MCR-SL-CUC-600-I 2308098Current measurement [A] 0 … 400 0 … 500 0 … 600Frequency ranges [HZ] DC; 20 … 6000 DC; 20 … 6000 DC; 20 … 6000Connection method Through connection 32 mm Ø Through connection 32 mm Ø Through connection 32 mm ØOutput signal 4…20 mA 4…20 mA 4…20 mALoad < 300 Ω < 300 Ω < 300 ΩSupply voltage 20 … 30 V DC 20 … 30 V DC 20 … 30 V DCTest voltage: input/output 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min.Test voltage: input/supply 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min. 3.5 kV, 50 Hz, 1 min.Ambient temperature [°C] -40 to +65 -40 to +65 -40 to +6548 PHOENIX CONTACT


SOLARCHECKstring monitoringMeasuring andcommunication modulesType Order No. SCK-C-MODBUS * 2901674 SCK-M-I-8S-20A * 2903241 SCK-M-I-4S-20A * 2903242 SCK-M-U-1500V* 2903591Current measurement [A] – 0 … 20 0 … 20 –Reverse current detection – - 1 A - 1 A –Voltage measurement [V DC] – – – 0 … 1500Interfaces RS-485 Modbus RTU – – Output signal 2 … 10 VSerial transmission speed 9.6 kbps – – –Supply voltage U B 24 V DC (-10% ... +25%) Via SCK-C-MODBUS Via SCK-C-MODBUS Via SCK-M-I moduleor separateOwn current consumption [mA] 12 45 45 35Temperature coeffi cient – 0.02%/K (from T > 25°C) 0.02%/K (from T > 25°C) < 0.03%/K (from T > 25°C)Transmission error,maximum– < 1% < 1% < 1%(following additional adjustment)Degree of protection IP20 IP20 IP20 IP20Ambient temperature [°C] -20 to +70 -20 to +70 -20 to +70 -20 to +70* new as of Intersolar 2013PHOENIX CONTACT 49


M12 cabling <strong>for</strong> sensors and devices in outdoor usePlug-in connector,<strong>for</strong> assemblyMaterial <strong>for</strong> screwconnection, stainless steel1.4404DescriptionPlug-in connector, with stainless steel knurl, insulation displacementconnection, unshielded, 4-pos.Plug-in connector, with M16 screw connection, screw connection,shielded, 5-pos.Type Order No. Socket, straight 1440766Pin, straight 1440753Socket, straight 1440782Pin, straight 1440779Socket, straight 1440038Pin, straight 1440012Socket, straight 1440041Pin, straight 1440025Cross section 0.14 mm 2 – 0.34 mm 2 0.34 mm 2 – 0.75 mm 2 0.25 mm 2 – 0.75 mm 2Cable diameter 3.5 mm ... 6 mm 4 mm ... 8 mm 3 mm ... 5.5 mm 5.5 mm ... 8.6 mmRated voltage 125 V 250 V 60 VRated current 4 A 4 ADegree of protection IP65/IP67 IP67/IP69KPropertiesTemperature range: -25°C to +80°C,M12 circular plug-in connector according to IEC 61076-2-101Temperature range: -40°C to +85°C,M12 circular plug-in connector according to IEC 61076-2-101M12 distributor withcorrosion-resistantmetal threadSensor/actuator box, M12socket, 8 slots, 5-pos., doubleoccupancy, no status indicatorDescription With master cable Plug-in screw connection, horizontalType Order No. 5 m 145736410 m 14573771457380Rated voltage 120 V 120 VRated current2 A 2 A<strong>for</strong> each I/O signalRated currentper slot4 A 4 ATotal rated current 12 A 10 ADegree of protection IP65/IP67/IP69K IP65/IP67PropertiesDistributor box: -30°C to +90°C,housing material: PBTDistributor box: -30°C to +80°C,housing material: PBT50 PHOENIX CONTACT


M12 SAC cableStainless steel knurlDescription 4-pos, cable type 28X 4-pos., cable type 28X, shielded 5-pos., cable type 28X 5-pos., cable type 28X, shieldedM12 plug toopen end, straight2 m 14540405 m 145405310 m 14540662 m 14541215 m 145413410 m 14541472 m 14072555 m 140725610 m 14072572 m 14072635 m 140726410 m 1407265M12 plug toopen end, angled2 m 14079655 m 140796610 m 1407967–––––––––M12 socket toopen end, straight2 m 14540795 m 145408210 m 14540952 m 14541505 m 145416310 m 14541762 m 14072585 m 140725910 m 14072602 m 14072665 m 140726710 m 1407268M12 socket toopen end, angled2 m 14079685 m 140796910 m 1407970–––––––––M12 plug toM12 socket, straight2 m 14541055 m 14541182 m 14541895 m 14541922 m 14072615 m 14072622 m 14072695 m 1407270Rated voltage 250 V 250 V 60 V 60 VRated current 4 A 4 A 4 A 4 ADegree of protection IP65/IP67/IP68/IP69K IP65/IP67/IP68/IP69K IP65/IP67/IP68/IP69K IP65/IP67/IP68/ IP69KTemperature range: -40°C to +105°C -40°C to +105°C -40°C to +105°C -40°C to +105°CM12 SAC cableStainless steel knurlDescription 8-pos., cable type 28X 8-pos., cable type 28X, shielded M12 Ethernet/PROFINET cable,4-pos,. cable type 93XM12 plug toopen end, straight2 m 14072715 m 140727210 m 14072732 m 14072795 m 140728010 m 14072812 m 14542025 m 145421510 m 1454228M12 socket toopen end, straight2 m 14072745 m 140727510 m 14072762 m 14072825 m 140728310 m 1407284–––M12 plug toM12 socket, straight2 m 14072775 m 14072782 m 14072855 m 1407286––M12 plug toM12 plug, straight––––2 m 14542315 m 1454244Rated voltage 30 V 30 V 250 VRated current 2 A 2 A 4 ADegree of protection IP65/IP67/IP68/IP69K IP65/IP67/IP68/IP69K IP65/IP67/IP68/IP69KTemperature range: -40°C to +105°C -40°C to +105°C -40°C to +105°CPHOENIX CONTACT 51


Industrial network technology: wireless and cable-based componentsWirelessnetwork componentsType Order No. FL WLAN 5100 2700718 FL WLAN EPA 5N 2700488 FL Bluetooth EPA 2692788Operating modes Access point, client Client, 5 GHz ClientAntenna3-pack,Integrated,Integrated,antennas not supplied as standard circular polarized special antennacircular polarized special antennaStandard IEEE 802.11 a/b/g/n IEEE 802.11 a/n Bluetooth, confi gurableup to 200 m (open fi eld)Special featuresIP20, cluster management,24 V DCIP65/67,power consumption < 1.8 wattIP65/67,power consumption < 1.1 wattCable-basednetwork componentsType Order No. FL Switch LM 4TX/2FX 2832658 FL NAT SMN 8 TX 2989365DescriptionManaged switchNAT routerwith two fi berglass portsSpecial notesRSTP support,Large Tree Support, fast ring detection,VLANIntegrated managed switchCable-basednetwork componentsType Order No. FL MGUARD RS2000 TX/TX VPN 2700642FL MGUARD RS4000 TX/TX VPN 2200515FL MGUARD RS2000 TX/TX 2700634FL MGUARD GT/GT 2700197Description Firewall router Router with intelligent fi rewallSpecial notesWith VPN functionality, SD card asstorage medium, extended temperaturerangeUp to 200 Mbps of data throughput,gigabit connectivity, SFP slots, statefulinspection fi rewall <strong>for</strong> maximum securityand extremely easy confi guration,replaceable confi guration memory52 PHOENIX CONTACT


Industrial communication technologyFiber optic mediaconvertersFor maximum immunity tointerference and ranges inindustrial Ethernet applications,fi berglass media converterstransparently convert Ethernetdata to fi ber optics.Type Order No. FL MC EF 1300 MM SC2902853FL MC EF 1300 MM ST2902854FL MC EF 1300 SM SC2902856FL MC EF WDM SET2902660DescriptionFiber optic media converters,multi-mode fi berglassFiber optic media converters,multi-mode fi berglassFiber optic media converters,single-mode fi berglassFiber optic media converters,single-mode fi berglass,full duplex communication via asingle fi berConnection SC duplex B-FOC(ST) SC duplex SC simplexTransmission length Maximum 10 km Maximum 10 km Maximum 36 km Maximum 38 kmTransmission speeds 10/100 Mbps 10/100 Mbps 10/100 Mbps 10/100 MbpsAuto negotiation modesAuto negotiation/auto MDI (X)Auto negotiation/auto MDI (X)Auto negotiation/auto MDI (X)Auto negotiation/auto MDI (X)MDI/MDI-X switchover Auto MDI (X) Auto MDI (X) Auto MDI (X) Auto MDI (X)IsolatorsThe isolators are used <strong>for</strong>electrical isolation incopper-based Ethernetnetworks.Type Order No.FL ISOLATOR 1000-RJ/RJ2313915FL ISOLATOR 100-RJ/RJ2313931FL ISOLATOR 100-RJ/SC2313928Description Galvanic Ethernet isolators Galvanic Ethernet isolators Galvanic Ethernet isolatorsConnection RJ45 socket, shielded RJ45 socket, shielded RJ45 socket and COMBICONplug-in screw terminal blockTransmission speeds 10/100/1000 Mbps 10/100 Mbps 10/100 MbpsTransmission lengths≤ 100 m(depending on the data rate andcable used)≤ 100 m(depending on the data rate andcable used)≤ 100 m(depending on the data rate andcable used)Electrical isolation Ethernet // Ethernet Ethernet // Ethernet Ethernet // EthernetTest voltage 4 kV AC (50 Hz, 1 min.) 4 kV AC (50 Hz, 1 min.) 4 kV AC (50 Hz, 1 min.)Copper-based datatransmissionThe per<strong>for</strong>mance and availabilityof bus systems can besignifi cantly increased by usingrepeaters.Type Order No. PSI-REP-RS485W2 2313096DescriptionRepeater <strong>for</strong> RS-485 2-wire systemsConnectionPlug-in screw connectionTransmission length1200 m, MaximumTransmission speedsof 4.8 to 500 kbpsElectrical isolation RS-485 (A) // RS-485 (B) // power supply //DIN rail connectorPHOENIX CONTACT 53


Industrialremote communicationGlobal networking, alarmgeneration, remote maintenance,and continual data acquisitionType Order No. TC DSL ROUTER X400 A/B 2902709TC DSL ROUTER X500 A/B 2902710PSI-MODEM-3G/Router 2314008 PSI-MODEM-SHDSL/ETH 2313643DescriptionIndustrial ADSL broadband router,supports ADSL/ADSL2/ADSL2+according to Annex A and BIndustrial UMTS/HSPA mobile phonerouter with fi rewall and VPN <strong>for</strong>worldwide network accessSHDSL Ethernet extender <strong>for</strong>point-to-point, line, and ring structureon in-house 2 and 4-wire cablesTelecommunications interfaceADSL/ADSL2/ADSL2+(Annex A and B), maximum 25 Mbps(downstream), 1 Mbps (upstream)850/900/1800/1900 MHzGPRS/EDGE (maximum 210 kbps),850/1900/2100 MHzUMTS/HSPA (maximum 7.2 Mbps)2-wire operation:32 kbps ... 15.3 Mbps4-wire operation:64 kbps ... 30 MbpsConnection 6P2C RJ11 socket, shielded SIM and backup SIM;SMA antenna connectionCOMBICON plug-in screw terminalblockLAN transmission speeds10/100 Mbps,auto negotiation10/100 Mbps,auto negotiation10/100 Mbps,auto negotiationElectrical isolation VCC // ADSL // Ethernet // FE VCC // UMTS // Ethernet // PE VCC // Ethernet // DSL (A) // DSL (B)Ambient temperature range -20°C ... 60°C -25°C ... 65°C -20°C ... 60°CFO convertersThe FO converters <strong>for</strong> serial datacommunication are perfect <strong>for</strong>deployment in free-standing systems.Long transmission lengths and a highlevel of EMI immunity guaranteeinterference-free data transmission.Type Order No. PSI-MOS-RS485W2/FO 660 E 2708313PSI-MOS-RS485W2/FO 660 T 2708300PSI-MOS-RS485W2/FO 850 E 2708339PSI-MOS-RS485W2/FO 850 T 2708326PSI-MOS-RS485W2/FO 1300 E 2708562Connection/wavelength FSMA/660 nm B-FOC (ST ® )/850 nm SC DUPLEX/1300 nmTransmission length70 m (with polymer fi ber),400 m (with HCS/PCF fi ber)2800 m (with HCS/PCF fi ber),up to 4200 m(with multi-mode fi berglass)Up to 25 km(with multi-mode fi berglass),up to 45 km(with single-mode fi berglass)Ambient temperature range -20°C … 60°C -20°C … 60°C -20°C ... 60°C54 PHOENIX CONTACT


WirelessdatacommunicationRadioline is the newwireless system <strong>for</strong>extended systems andnetworks <strong>for</strong> up to250 stations.Type Order No. RAD-2400-IFS 2901541 RAD-DI4-IFS 2901535RAD-DOR4-IFS 2901536RAD-DI8-IFS 2901539RAD-DO8-IFS 2902811RAD-DAIO6-IFS 2901533RAD-AI4-IFS 2901537RAD-PT100-4-IFS 2904035RAD-AO4-IFS 2901538RAD-CONF-RF3 2902814RAD-CONF-RF5 2902815RAD-CONF-RF7 2902816RAD-MEMORY 2902828RAD-CABLE-USB 2903447 transceiver with RS-232,RS-485 2-wire interface,expandable with I/Oextension modules network connections(line, star, mesh) and serial data technology I/O-to-I/O, I/O-to-serial,serial-to-serial I/Oextension modules (0...250 V AC/DC) transistor outputs via thumbwheel modules (0/4 ... 20 mA) Pt 100 sensors (0/4 ... 20 mA or 0 ... 10 V) via thumbwheelAccessories via plug-in confi gurationmemory <strong>for</strong> secure, paralleloperation of multiplenetworks <strong>for</strong> saving customconfi guration data and extended confi guration (including antennas,connecting cables) can befound on the InternetFiber opticinstallation techniqueFor industrial solutionswhich are easy to install andmaintain.Type Order No. HCSO-1015 2901557 GDO-1017 2901559 PSM-SET-FSMA/4-HCS2799487PSM-SET-B-FOC/4-HCS2708481PSM-SET-SCRJ-DUP/2-HCS2313070PSM-HCS-KONFTOOL/SC-RJ2708876DescriptionHCS outdoor cables <strong>for</strong>assembly, lengths, and fi beroptic plugs (IP20)that can be combined asrequired, cables can also beordered by the meter withoutplugsMulti-mode fi berglass outdoorcables <strong>for</strong> assembly, lengths, andfi ber optic plugs (IP20) that canbe combined as required, cablescan also be ordered by themeter without plugsQuick mounting plug <strong>for</strong>HCS/PCF cablesAssembly kit <strong>for</strong> HCS fi bercables, all tools <strong>for</strong> simple andquick plug assemblyPHOENIX CONTACT 55


Controllers and I/O systemsCompact controller andbus couplerType Order No. ILC 131 ETH/XC 2701034ILC 151 ETH/XC 2701141ILC 151 GSM/GPRS- 2700977 ILC 171 ETH 2TX 2700975 ILC 191 ME/INC 2700075ILC 191 ME/AN 2700074DescriptionCompact controller withextended temperature rangeCompact controller withmodemCompact controller with2 Ethernet portsCompact controller <strong>for</strong> drivecontrolSpecial featureSuitable <strong>for</strong> increasedtemperature requirementsIntegrated GSM/GPRS-modem,integrated Modbus/TCP clientPlug-in parameterizationmemory (SD Flash with512 Mbytes or 2 Gbytes),integrated Modbus/TCP clientAnalog or incrementalinput channels <strong>for</strong> positiondetectionProcessing speed90 μs per 1000 instructions(bit data system)90 μs per 1000 instructions(bit data system)90 μs per 1000 instructions(bit data system)90 μs per 1000 instructions(bit data system)Interfaces 1 x INTERBUS; 1 x Ethernet 1 x INTERBUS; 1 x Ethernet 1 x INTERBUS; 2 x Ethernet 1 x INTERBUS; 1 x EthernetAmbient temperature -40°C to +60°C -25°C to +55°C -25°C to +55°C -25°C to +55°CWidth 80 mm 85 mm 80 mm 164 mmI/O systems in thecontrol cabinetType Order No. IB IL 24 DI 2-PAC 2861221IB IL 24 DI 4-PAC 2861234IB IL 24 DI 8-PAC 2861247IB IL 24 DI 8/HD-PAC 2700173IB IL 24 DI 16-PAC 2861250IB IL 24 DI 32/HD-PAC 2862835IB IL 24 DO 2-PAC 2861470IB IL 24 DO 4-PAC 2861276IB IL 24 DO 8-PAC 2861603IB IL 24 DO 8/HD-PAC 2700173IB IL 24 DO 16-PAC 2861292IB IL 24 DO 32/HD-PAC 2862822IB IL AI 2/SF-PAC 2861302IB IL AI 4/I-PAC 2700458IB IL AI 4/U-PAC 2700459IB IL AI 4/EF-PAC 2878447IB IL AI 8/SF-PAC 2861412IB IL AI 8/IS-PAC 2861661IB IL AO 1/U/SF-PAC 2861399IB IL AO 1/SF-PAC 2861315IB IL AO 2/UI-PAC 2700775IB IL AO 2/SF-PAC 2863083IB IL AO 2/U/BP-PAC 2861467IB IL AO 4/8/U/BP-PAC 2878036Description Digital input terminal Digital output terminal Analog input terminal Analog output terminalNumber of channels 2 – 32 2 – 32 2 – 8 1 – 8Ambient temperature -25°C to +55°C -25°C to +55°C -25°C to +55°C -25°C to +55°CWidth 12 – 48 mm 12 – 48 mm 12 – 48 mm 12 – 48 mmI/O systems in the fieldType Order No. FLM DI 8 M8 2773348 FLM DIO 8/4 M8 2773351 FLM DO 4 M8-2A 2736932 FLM DIO 8 M8 2736893Description 8 inputs 8 inputs 8 outputs 8 outputsNumber of channels -25°C to +60°C -25°C to +60°C -25°C to +60°C -25°C to +60°CAmbient temperature 29.8 mm 29.8 mm 29.8 mm 29.8 mmWidthIP65/67(protected against dust and jetwater)IP65/67(protected against dust and jetwater)IP65/67(protected against dust and jetwater)IP65/67(protected against dust and jetwater)56 PHOENIX CONTACT


Compact controller and buscouplerType Order No. IL MOD BK DI8 DO4-PAC2878696IL ETH BK DI8 DO4 2TX-PAC2703981IL CAN BK-TC-PAC2718701Description Bus coupler <strong>for</strong> Modbus/RTU (ASCII) Bus coupler <strong>for</strong> Modbus/TCP(UDP)Bus coupler <strong>for</strong> CANopen®Special feature – – –Processing speed – – –Interfaces 1 x D-SUB-9 socket 2 x RJ45 socket 2 x 5-pos. TWIN-COMBICON plugAmbient temperature -25°C to +55°C -25°C to +55°C -25°C to +55°CWidth 80 mm 80 mm 85 mmI/O systems in the controlcabinetType Order No. IB IL 24/230 DOR1/W-PAC 2861881IB IL 24/230 DOR4/W-PAC 2861878IB IL 24/230 DOR1/W-PAC 2862178IB IL 24/230 DOR1/W-PC PAC 2862181IB IL RS 232-PAC 2861357IB IL RS 232-PRO-PAC 2878722IB IL RS 485/422-PAC 2861933IB IL RS 485/422-PRO-PAC 2863627IB IL RS-UNI-PAC 2700893IB IL CAN-MA-PAC 2700196IB IL IFS-MA-PAC 2692720IB IL PB-MA-PAC 2700631IB IL FLM MULTI-PAC 2727009Description Digital relay output terminals Communication terminals Communication terminalsNumber of channels 1 – 4 1 1Ambient temperature -25°C to +55°C -25°C to +55°C -25°C to +55°CWidth 12 – 48 mm 12 – 48 mm 12 – 48 mmPHOENIX CONTACT 57


HMIs <strong>for</strong> basic applicationsWeb panel/widescreen web panelType Order No. WP 06T 2913645 WP 07T/WS 2700307 WP 09T/WS 2700309Display 7.1 cm/2.8" TFT active 17.8 cm/7" TFT active 22.9 cm/9" TFT activeResolution 320 x 240 pixels (QVGA) 800 x 480 pixels (WVGA) 800 x 480 pixels (WVGA)Ambient temperature 0°C to +50°C 0°C to +50°C 0°C to +50°COutdoor web panelVersions with sunlight-readabledisplays, UV resistant, suitable <strong>for</strong>an extended temperature rangeType Order No. WP 06T/XC 2701555 WP 07T/XC 2701556Display 14.5 cm/5.7" TFT active 17.8 cm/7" TFT activeResolution 320 x 240 pixels (QVGA) 800 x 480 pixels (WVGA)Ambient temperature -20°C to +70°C -20°C to +70°CMinitouchInexpensive visualization unit,ideal <strong>for</strong> applications in whichin<strong>for</strong>mation needs to be displayedin alphanumeric <strong>for</strong>mat.Type Order No. TD 1030T 2701257Display7.1 cm/2.8" TFT activeResolution320 x 240 pixels (QVGA)Ambient temperature0°C to +50°C58 PHOENIX CONTACT


Energy metersEMproType Order No. EEM-MA600-24DC 2902352 EEM-MA600 2901366 EEM-MA400 2901364Voltage measurement direct Up to 700 V AC Up to 700 V AC Up to 500 V ACVoltage measurement via voltagetransducer Current measurement Direct up to 6 A/via current trans<strong>for</strong>merDirect up to 6 A/via current trans<strong>for</strong>merVia current trans<strong>for</strong>mer Active <strong>energy</strong>/reactive <strong>energy</strong> kWh +/- / kvarh +/- kWh +/- / kvarh +/- kWh + / kvarh +2-tariff THD (Total Harmonic Distortion) Up to 63rd harmonic Up to 63rd harmonic Up to 51st harmonic Outputs Optionally with special function module Optionally with special function module Optionally with special function moduleCommunicationOptionally with communication module;RS-485 JBUS/MODBUS; PROFIBUS;Ethernet; RS-485/Ethernet GatewayOptionally with communication module;RS-485 JBUS/MODBUS; PROFIBUS;Ethernet; RS-485/Ethernet GatewayOptionally with communication module;RS-485 JBUS/MODBUS EMproType Order No. EEM-MA250 2901363 EEM-MA200 2901362Voltage measurement direct Up to 500 V AC Up to 500 V ACVoltage measurement via voltagetransducerCurrent measurement Via current trans<strong>for</strong>mer Via current trans<strong>for</strong>mer Active <strong>energy</strong>/reactive <strong>energy</strong> kWh + / kvarh + kWh + / kvarh +2-tariff THD (Total Harmonic Distortion) Up to 51st harmonic Up to 51st harmonic OutputsPulse output or alarm,Pulse output or alarm,confi gurableconfi gurable UL listed According to 61010-1 According to 61010-1PHOENIX CONTACT 59


SoftwareProgramming and visualizationType Order No. PC WORX DEMO 2985725 WebVisit 6 EXPRESS 2700954 AXweb+Licenses available on request Licenses available on request Licenses available on requestDescriptionSoftware package <strong>for</strong> PC-basedautomation solutionsDevelopment software <strong>for</strong> web-basedvisualizationsWeb-based in<strong>for</strong>mation and controlsystemSystem requirementsMS Windows XP SP3,MS Windows Vista Business SP2,MS Windows 7 Professional(32/64-bit) SP1MS Windows XP SP3,MS Windows Vista Business,MS Windows 7 Professional (32/64-bit)Client side: every operating system musthave a current browser and JavaScriptServer side: MS Windows 2008 R2(64-bit), SQL Server 2008 R2Hybrid motor startersCONTACTRONFor starting and reversing 3 ACmotors up to 4 kW. Only 22.5 mmwide, they combine up to fourfunctions: right-side protection,left-side protection, motorprotection relay, and emergencystop up to category 3/PLeType Order No. ELR H5-IES-SC-24DC/500AC-22900414ELR H5-I-SC-24DC/500AC-22900574ELR H5-SC- 24DC/500AC-92900538Input voltage 24 V DC 24 V DC 24 V DCOutput voltage 42 V AC … 550 V AC 42 V AC … 550 V AC 42 V AC … 550 V ACLoad current Maximum 2.4 A Maximum 2.4 A Maximum 9 AAmbient temperature range -25°C to +70°C -25°C to +70°C -25°C to +70°CCONTACTRONFor starting and reversing 3 ACmotors up to 4 kW. Only 22.5 mmwide, they combine up to fourfunctions: right-side protection,left-side protection, motorprotection relay, and emergencystop up to category 3/PLeType Order No. ELR H5-IES-SC-230AC/500AC-22900420ELR H5-I-SC-230AC/500AC-22900575ELR H5-SC-230AC/500AC-92900539Input voltage 120/230 V DC 120/230 V DC 120/230 V DCOutput voltage 42 V AC … 550 V AC 42 V AC … 550 V AC 42 V AC … 550 V ACLoad current Maximum 2.4 A Maximum 2.4 A Maximum 9 AAmbient temperature range -25°C to +70°C -25°C to +70°C -25°C to +70°C60 PHOENIX CONTACT


Surge protection: set solutionsPV setsType Order No. PV-SET 1ST/1000DC/1MPP-SPD-SC2801529PV-SET 2ST/1000DC/2MPP-SPD-SC2801317PV-SET 3ST/1000DC/3MPP-SPD-SC2801531DescriptionLightning current and surge arrester inIP65 housing <strong>for</strong> protecting single-stringphotovoltaic systems up to 1000 V DC,connection via SUNCLIX plug/socket.Lightning current and surge arrester inIP65 housing <strong>for</strong> protecting the DC sideof an inverter with two MPP trackers upto 1000 V DC, connection via SUNCLIXplug/socket, plug-in varistors withthermal disconnect device between L+,L-, and ground/PE.Lightning current and surge arrester inIP65 housing <strong>for</strong> protecting the DC sideof an inverter with three MPP trackersup to 1000 V DC, connection viaSUNCLIX plug/socket, plug-in varistorswith thermal disconnect device betweenL+, L-, and ground/PE.Cross section [mm2] 2.5 – 15 2.5 – 15 2.5 – 15Maximum continuous voltage U CPV 1000 V DC 1000 V DC 1000 V DCNominal load current I L ≤ 80 A DC ≤ 80 A DC ≤ 80 A DCShort-circuit current I SCSTC 25 A DC 25 A DC (per MPP) 25 A DC (per MPP)PV setsType Order No. PV-SET 1000 DC/AC2804458PV-SET 5ST/600DC2920780PV-SET-16ST-1000/F-M-SPD-SD-SC2801203DescriptionSurge protection in IP65 housing <strong>for</strong>the AC and DC sides of an inverter <strong>for</strong>single string photovoltaic systems up to1000 V DC.Surge protection in IP65 housing <strong>for</strong> theDC side of an inverter <strong>for</strong> fi ve-stringphotovoltaic systems up to 600 V DC.Plug-in varistors with a thermaldisconnect device between L+, L-, andground/PE. With generator disconnectand modular terminal blocks.Surge protection in IP65 housing <strong>for</strong> theDC side of an inverterFor 16-string photovoltaic systems up to1000 V DC and the MODBUScommunication.With monitoring system (SCK-M), twoDC switch disconnectors and fuseholders <strong>for</strong> L+ and L-Cross section [mm2] 1.5 – 35 0.2 – 16 2.5 – 15Maximum continuous voltage U CPV 1000 V DC/230 V AC 600 V DC 1000 V DCNominal load current I L ≤ 80 A DC/AC ≤ 30 A DC –Short-circuit current I SCSTC – – 8.5 A DC (per string)PHOENIX CONTACT 61


Miniature connection system <strong>for</strong> building-integrated <strong>photovoltaics</strong> – BIPVSUNCLIX miniOrder No. 1795336 1795323 1463065 1811239Description Pin (-) Socket (+) DC string diode withSUNCLIX mini plug-inconnectorDC string diode without plug-inconnector, free cable endsCross section 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2Rated voltage 1000 V 1000 V 1000 V 1000 VNominal current Maximum 15 A Maximum 15 A Maximum 5 A Maximum 5 AReverse voltage – – 2200 V 2200 VCable length – – 800 mm 800 mmDimensions Ø 11 mm Ø 11 mm 100 x 38 x 11 mm 100 x 38 x 11 mmDegree of protection IP67 IP67 IP67 IP67PropertiesTemperature range: -40°C to +85°C, class II protection,VDE-certifi ed according to DIN EN 50521Temperature range: -40°C to +85°C, class II protection,VDE-certifi ed according to DIN EN 50548SUNCLIX miniOrder No. 1705132 1705131Description Left module junction box Right module junction boxCross section 2.5 mm2 2.5 mm2Rated voltage 1000 V 1000 VNominal current Maximum 15 A Maximum 15 AReverse voltage – –Cable length 500 mm 500 mmDimensions 92 x 40.4 x 9.5 mm 92 x 40.4 x 9.5 mmDegree of protection Process-dependent Process-dependentPropertiesTemperature range: -40°C to +85°C,VDE certifi cation according to DIN EN 50548 in progress62 PHOENIX CONTACT


Autonomous power supply<strong>Solar</strong> systemsType Order No. RAD-SOL-SET-24-100 2885472 RAD-SOL-SET-24-200 2917722Nominal voltage [V] 24 DC 24 DCMaximum power [Wp] 100 200Battery capacity [Ah] 40 100Maximum load [W] 0 W ... 11 W(maximum connected load <strong>for</strong>year-round constant load in relation topower reserve and installation location)0 W ... 23 W(maximum connected load <strong>for</strong>year-round constant load in relation topower reserve and installation location)AccessoriesTool kitFor on-site deployment, the solartool kit includes the commerciallyavailable solar connector, tools <strong>for</strong>cutting, stripping, and crimping <strong>for</strong>working.Type Order No. TOOL KIT SOLAR 1212071 SZF 1-0.6X3.5 1204517 WIREFOX-D SR 6-1 1212511Description <strong>Solar</strong> tool kit Screwdriver Stripping toolsMARKING systemMARKING system is the intelligentsolution <strong>for</strong> quick and easy labelingof terminals, conductors, cables,and devices.Type Order No. THERMOMARK CARD 5146464 THERMOMARK ROLL 5145477 MARKING BOX 5147100MARKING BOX EN 5147101DescriptionThermal transfer printers <strong>for</strong>sheet materials and cards, including:Thermal transfer printers <strong>for</strong>roll material, including:(20 x 8) 1000 labelsComplete marking systemconsisting of:(5146464)(5146477)professional software <strong>for</strong>immediate startup,PHOENIX CONTACT 63


Always up-to-date, always available to you. Hereyou'll find everything on our products, solutionsand service:phoenixcontact.netProduct rangemotor control PHOENIX CONTACT GmbH & Co. KGPhone: +49 (0) 52 35 3-00 phoenixcontact.netIS 01-12.000.L3.2012 Printed in GermanyMNR 5200595 3 /2013-03-01/05 © PHOENIX CONTACT 2013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!