12.07.2015 Views

Lighting Columns Brochure - Abacus Lighting

Lighting Columns Brochure - Abacus Lighting

Lighting Columns Brochure - Abacus Lighting

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Flange Plate Mounting<strong>Abacus</strong> offers a choice of passive and non passive concretefoundations for flange plate mounting of lighting columns.By taking the OTM (overturning moment) from the column datamatrix in the brochure, and identifying the correct groundpressure, the fully factored concrete foundation dimension canNon-passive mass concretefoundation dimensionsbe determined from the tables below. Foundation O.T.M(kNm)A non-passive foundation, where the ground pressure may belower, takes no account of the side forces and is thereforeshallower but wider.BearingPressure(kNm)A Width(mm)B Depth(mm)Holding down boltprojection & final torqueBolt Size & GradeProjection(mm)Torque(Nm)M16*500 Long Grade 4.6 125 25M20*500 Long Grade 4.6 125 50M24*600 Long Grade 4.6 125 160M30*800 Long Grade 4.6 150 310Passive mass concrete foundationA passive foundation, where the ground pressure must be atleast 150kN/m (or 1.5bar), takes into account the side forcesapplied from the firmer ground. As a result, the concrete istypically narrower and deeper than non-passive.FoundationO.T.M(kNm)BearingPressure(kNm)A Width(mm)B Depth(mm)3P150 3 150 650 7504P150 4 150 700 8005P150 5 150 750 8006P150 6 150 750 9008P150 8 150 850 95010P150 10 150 900 95015P150 15 150 950 110020P150 20 150 1050 120030P150 30 150 1200 125040P150 40 150 1250 130050P150 50 150 1350 14003M75 3 75 880 5903M100 3 100 880 5903M150 3 150 880 5904M75 4 75 950 6254M100 4 100 950 6254M150 4 150 950 6255M75 5 75 1050 6755M100 5 100 1050 6755M150 5 150 1050 6756M75 6 75 1100 7006M100 6 100 1100 7006M150 6 150 1100 7008M75 8 75 1150 7258M100 8 100 1150 7258M150 8 150 1150 72510M75 10 75 1250 77510M100 10 100 1250 77510M150 10 150 1250 77515M75 15 75 1400 85015M100 15 100 1350 82515M150 15 150 1350 82520M75 20 75 1500 90020M100 20 100 1500 90020M150 20 150 1500 90030M75 30 75 1700 100030M100 30 100 1700 100030M150 30 150 1700 100040M75 40 75 1900 110040M100 40 100 1800 105040M150 40 150 1800 105050M75 50 75 2100 120050M100 50 100 1900 110050M150 50 150 1900 1100Soil pressure distributionPassiveconcreteTypically usedwith good groundwith groundbearing pressureof not less than150kNmNon-passiveconcreteTypically usedwith uniform orpoor subsoil withground bearingpressure of75-150kNmTypical sectionthrough foundationBolt ProjectionTemplateTemporarySupportBCable DuctSpacerPlateALower Template• Pressure distribution• Pressure distributionProfessional lighting systems to suit any project. Call 01623 518 333 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!