The new range of Consumer <strong>units</strong> is designed to helpinstallers meet the high demands of the moderndomestic installation.The choice of product includes all of the previouspopular models such as the split load <strong>units</strong> plus someadditional models designed to comply with the 17thedition wiring regulations.These include High Integrityand Dual RCD boards.Another addition to the range is a single module 18mm30mA RCBO in ratings from 6 Amp to 50 Amp for theadditional protection of individual circuits. New models for the 17th Edition ie:High Integrity and Dual RCD Models. Flexible split load <strong>units</strong> to allow configuration on site. New range of Single Module Single Pole RCBO’s. Translucent visor for discreet appearance. Raised DIN rail providing top and bottomwiring routes. Full DIN rail allows for use of DIN Accessories ie:Timers, Contactors. New modern curved style insulated <strong>consumer</strong> unit. Large enclosures allowing ample wiring space. All round cable entry-top, bottom, sides and rear. Raised DIN Rail providing topand bottom wiring entries Cable through path beneath DIN rail Large metal enclosuresallowing additional wiringspace and fitting of1 module RCBO’s Modern curved styling Neutral colour Fixing slots for leveladjustment Quarter turn screws forquick release cover Dual type screw head2


Making Sense of the 17th Edition Wiring Regulations• All socket outlets should be protected by 30mA RCD whether on the ground floor of a house or thetop floor of a high rise apartment block• All circuits in a room with a fixed bath or shower should be protected by one or more 30mA RCDs• All cable buried beneath the plaster surface of a wall or partition (at less than 50mm) should beprotected by 30mA RCDs• All cables concealed in metal stud partitions (common in new builds) should be protected by 30mA RCDs• Installations should be divided up into circuits so as to take account of danger and inconvenience caused by asingle fault - e.g. such as a lighting circuit• Installations should be designed and arranged so as to prevent unwanted tripping of RCDsSUMMARY TABLEREGULATIONS RELATING TO: EXAMPLES ADDITIONAL PROTECTION411.3.3 Sockets up to 20A Upstairs sockets 30mA RCDrating for general use Downstairs Socketsby ordinary persons Kitchen SocketsCooker outlet with integral 13A socketGarage SocketsPlus any other sockets up to 20A rated701.411.3.3 All circuits in a room Shower circuit 30mA RCDwith a fixed bathLighting circuitor showerHeating circuitVentilation circuitShaver socketPlus other circuits522.6.6 All circuits buried Downstairs lighting 30mA RCD522.6.7 in a wall or partition Upstairs lightingand at less than 50mm Immersion heater522.6.8 and without Burglar alarmmechanical protection Smoke alarmsPlus any other circuitsBritish standard and IEE regulations are subject to change and amendments. This guide to Sector <strong>consumer</strong> <strong>units</strong> is not a substitute for the regulationswhich should always be used for all types of electrical installation design and installation work. All round cable entry;top, bottom and sides Open cable entries Large cableentries for singlepoint cable entryapplication Large insulatedenclosures allowingadditional wiringspace and fitting of1 module RCBOs Translucent visorfor discreetappearance3


17th Edition CompliantCONSUMER UNITS - AN EXPLANATION OF THE DIFFERENT TYPESMAIN SWITCH CONTROLLED UNITS Can provide 100% RCD protectionCOOKERSHOWERSOCKETS UPSOCKETS DOWNSOCKETS KITCHENIMMERSION HEATERLIGHTS UPLIGHTS DOWNBATHROOM LIGHTSSMOKE ALARM Simplest solution Can provide independent RCD protectionfor all circuits resulting in the safest solution Allows for any RCD exemptions that maybe required100A DP40A RCBO40A RCBO32A RCBO32A RCBO32A RCBO16A RCBO6A RCBO6A RCBO6A RCBO6A RCBOSPARESPARESPARESPARE Enables the use of narrower <strong>consumer</strong> <strong>units</strong>SPLIT LOAD UNITS100A DPCOOKER40A RCBOSOCKETS DOWN32A RCBOSMOKE ALARM6A RCBOLIGHTS UP6A RCBOBATHROOM LIGHTS6A RCBOSPARESPARELIGHTS DOWN6A MCBIMMERSION HEATER16A MCBSOCKETS KITCHEN32A MCBSOCKETS UP32A MCBSHOWER40A MCB80A30mA Can provide 100% RCD protection Can provide independent RCD protection forselected circuits Allows for any RCD exemptions that may berequired Some circuits may be grouped at the discretionof the installer Other circuits have independent RCD protection No increase in the width of <strong>consumer</strong> unit orloss in the number of outgoing circuits whencompared to today's most commonly installed<strong>units</strong>.DUAL RCD SPLIT LOAD UNITS Provides 100% RCD protectionCOOKERSOCKETS KITCHENSOCKETS UPLIGHTS DOWNBATHROOM LIGHTSLIGHTS HALL& STAIRSLIGHTS UPSOCKETS DOWNSHOWER Circuits are distributed into two groups MCBS are utilised throughout The installer is required to display carefulconsideration when deciding upon finalcircuit groupings100A DP80A30mA40A MCB32A MCB32A MCB6A MCB6A MCBSPARE6A MCB6A MCB32A MCB40A MCB63A30mAHIGH INTEGRITY DUAL RCD SPLIT LOAD UNITSMOKE ALARMBATHROOM LIGHTSLIGHTS UPSOCKETS DOWNSOCKETS KITCHENSHOWERLIGHTS HALL& STAIRSLIGHTS DOWNSOCKETS UPCOOKER Can provide 100% RCD protection Can provide independent RCD protection forselected circuits Allows for any RCD exemptions that may berequired100A DP6A RCBO6A RCBO6A MCB32A MCB32A MCB40A MCB63A30mA6A MCB6A MCB32A MCB40A MCB63A30mA Some circuits may be grouped at the discretionof the installer4


17th Edition CompliantINSULATED CONSUMER UNITSPart Code No of Main Dimensions (mm)No. 0001 Ways Incomer Height Width DepthMain Switch Incomer Main incomer 100A DP (63A Double Pole for 2 Way board)SVCU2/INS 147535 2 63A 225 141 111SVCU5/INS 147548 5 100A 225 194 111SVCU8/INS 147551 8 100A 225 248 111SVCU11/INS 147564 11 100A 225 302 111SVCU14/INS 147577 14 100A 225 355 111Part Code No of Ways No of Ways Dimensions (mm)No. 0001 Unprotected Protected by RCD Height Width DepthSplit Load Main incomer 100A Double Pole for all circuits plus 80A 30mA DP RCD for selected circuitsSVCU33/INS 147580 3 3 225 248 111SVCU54/INS 147603 5 4 225 302 111SVCU66/INS 147616 6 6 225 355 111SVCU98/INS 147632 9 8 225 445 111Part Code No of Usable Dimensions (mm)No. 0001 Ways Height Width DepthFlexible Units Main incomer 100A Double Pole for all circuits plus 80A 30mA DP RCD for selected circuitsSVCUFSL9/INS 147593 9 225 302 111SVCUFSL12/INS 147629 12 225 355 111Part Code No of Ways No of Ways Dimensions (mm)No. 0001 Unprotected Protected by RCD Height Width DepthHigh Integrity Main incomer 100A Double Pole for all circuits plus 2 x 30mA DP RCD for selected circuitsSVCU244HI/INS 147645 2 4 4 225 355 111SVCU433HI/INS 147658 4 3 3 225 355 111SVCU465HI/INS 147661 4 6 5 225 445 111Dual RCCB Main incomer 100A Double Pole for all circuits plus 2 x 30mA DP RCD for selected circuitsSVCU43DR/INS 147674 - 4 3 225 302 111SVCU55DR/INS 147687 - 5 5 225 355 111SVCU87DR/INS 147690 - 8 7 225 445 111Part Code No of Ways RCD Rating Dimensions (mm)No. 0001 Height Width DepthRCCB Incomer Main incomer 63A or 80A 30mA DP RCDSVCU2A/INS 147700 2 63A 30mA 225 141 111SVCU5A/INS 147713 5 80A 30mA 225 194 111SVCU8A/INS 149999 8 80A 30mA 225 248 111Main switch IncomerSplit LoadAttractive Curved Profilefeaturing Smoked Cover High IntegrityDual RCCB RCCB Incomer5


17th Edition CompliantMETAL CONSUMER UNITSPart Code No of Main Dimensions (mm)No. 0001 Ways Incomer Height Width DepthMain Switch Incomer Main incomer 100A Double Pole (63A Double Pole for 2 Way board)SVCU2/MTL 147726 2 63A 210 126 96SVCU5/MTL 147739 5 100A 238 188 123SVCU8/MTL 147742 8 100A 238 241 123SVCU11/MTL 147755 11 100A 238 292 123SVCU14/MTL 147768 14 100A 238 345 123Part Code No of Ways Dimensions (mm)No. 0001 Protected by RCD Height Width DepthDual RCCB Main incomer 100A Double Pole for all circuits plus 2 x 30mA DP RCD for selected circuitsSVCU43DR/MTL 147771 4 3 238 292 123SVCU55DR/MTL 147784 5 5 238 345 123SVCU87DR/MTL 147797 8 7 238 438 123Part Code No of Ways RCD Rating Dimensions (mm)No. 0001 Height Width DepthRCCB Incomer Main incomer 63A or 80A 30mA DP RCDSVCU2A/MTL 147807 2 63A 30mA 210 126 96SVCU5A/MTL 147810 5 80A 30mA 238 188 123Main switch IncomerTough Metal Unitfeatures Transparent Cover6Dual RCCBRCCB Incomer


17th Edition CompliantMODULES & ACCESSORIESPart Code RatingNo. 0001Miniature Circuit Breakers (MCB) Type B, 6kA Breaking CapacitySVMCB6/B 147823 6ASVMCB10/B 147836 10ASVMCB16/B 147849 16ASVMCB20/B 147852 20ASVMCB32/B 147865 32ASVMCB40/B 147878 40ASVMCB50/B 147881 50ARCBO (MCB / RCCB, 1 mod) Type B & C, 6kA Breaking CapacitySVRCBO6 147894 6ASVRCBO10 147904 10ASVRCBO16 147917 16ASVRCBO20 147920 20ASVRCBO32 147933 32ASVRCBO40 147946 40ASVRCBO50 147959 50AResidual Current Circuit Breaker - Double Pole (RCCB or RCD)SVRCCB25/DP 147975 25A 30mASVRCCB40/DP 147988 40A 30mASVRCCB63/DP 147991 63A 30mASVRCCB80/DP 148000 80A 30mAPart Code DescriptionNo. 0001Blanking PiecesSVBLNK4 147962 BLANKSConsumer Unit Kits InsulatedSVGARAGE/INS 148013 GARAGE UNIT 63A 6A+16ASVSHOWER/INS 148026 SHOWER UNIT 63A 50A+BLNKSPECIFICATIONSAssembled UnitsBS EN 60439-3Main SwitchBS EN 60947-3Rating: 63A 240V 50Hz / 100A240V 50HzPole Configuration:Double poleMCBBS EN 60898Current Rating: 6A - 50AShort Circuit Breaking Capacity:6000AType Classification: B (3-5In)Pole Configuration: Single poleRCBOBS EN 61009Short Circuit BreakingCapacity: 6000ACurrent Rating: 6A - 50ARated Residual OperatingCurrent: 30mA Type ACType Classification: B (3-5In)Type Classification: C (5-10In)Rated Voltage: 230V, RatedFrequency: 50Hz (Electronic)Pole Configuration: Single polewith unswitched neutralRCCB or RCDBS EN 61008Rating: 63A & 80ARated Residual OperatingCurrent: 30mA Type ACPole Configuration:Double poleRated Voltage: 230V, RatedFrequency: 50Hz(Electro-mechanical)4 Module Enclosure InsulatedMain SwitchSVMS100 148039 100A Double PoleBell TransformerSVBTR5 148042 12V BELL TRANSFORMERDigital TimeclockSV7TC 148055 1 CHANNEL 24hr 7 DAYGeneral Purpose EnclosuresSVE2/INS 148068 2MOD DIN ENC INSULATEDSVE4/INS 148071 4MOD DIN ENC INSULATEDSVFOR4/MTL 148084 4MOD DIN ENC METALAll goods sold subject to Standard Conditions of Sale. Our policy is one of continuous improvementand we reserve the right to alter product specifications in this brochure. All information in thisbrochure is given in good faith and believed to be correct at the time of publication (June 2008).Customers should check with <strong>Senate</strong> Electrical for full product specifications. E. & O. E.© Copyright of <strong>Senate</strong> Electrical 2008. Given the volatility of raw material prices over the last12 months, whilst every effort is made to ensure the prices and information within this brochureare correct, prices charged will be those ruling at date of despatch and are all subject to VAT.RCBOMCBRCCB7


<strong>Senate</strong> Branch Locations729F11283463691112H3H4401415101617F5192054C9212249SCOTLANDABERDEEN AB16 6TXTel: 01224 690981Fax: 01224 695540AIRDRIE ML6 9BGTel: 01236 779080Fax: 01236 779066DUMBARTON G82 2RPTel: 01389 764200Fax: 01389 742752DUNDEE DD2 3QNTel: 01382 819595Fax: 01382 832211DUNFERMLINE KY11 2SLTel: 01383 413401Fax: 01383 417271EDINBURGH EH11 3XXTel: 0131 443 8976Fax: 0131 455 7313GLASGOW G51 3HZTel: 0141 445 2411Fax: 0141 445 4346GREENOCK PA15 4AXTel: 01475 723600Fax: 01475 727677PAISLEY PA3 1QGTel: 0141 889 6188Fax: 0141 889 6426NORTHBANGOR LL57 4SUTel: 01248 370093Fax: 01248 355224BARROW LA14 5UGTel: 01229 835773Fax: 01229 870228BLACKPOOL FY1 3LPTel: 01253 626528Fax: 01253 752661BRADFORD BD4 7NETel: 01274 394446Fax: 01274 395431BRADFORD -SUNBRIDGE BD5 0EQTel: 01274 735329Fax: 01274 737539DEESIDE -SUNBRIDGE CH5 2NYTel: 01244 280507Fax: 01244 280503FLINT CH6 5UYTel: 01352 730011Fax: 01352 730808GATESHEAD NE3 3DTTel: 0191 477 3961Fax: 0191 490 1163HUDDERSFIELD HD2 1XTTel: 01484 511340Fax: 01484 511347HULL HU5 1SGTel: 01482 323447Fax: 01482 216810KENDAL LA9 6LZTel: 01539 740588Fax: 01539 740280LEEDS LS12 6DNTel: 0113 243 5421Fax: 0113 242 5677LOUTH LN11 0YBTel: 01507 600730Fax: 01507 606777MANCHESTER M17 1SRTel: 0161 872 0409Fax: 0161 872 0343MIDDLESBROUGH TS1 5JPTel: 01642 210351Fax: 01642 245484MIDDLESBROUGH -EMS TS2 1RTTel: 01642 232090Fax: 01642 247694PENRITH CA11 9BLTel: 01768 892424Fax: 01768 892191PRESTON PR1 5DPTel: 01772 651191Fax: 01772 651226SHEFFIELD S9 5EXTel: 0114 261 1027Fax: 0114 261 9310SHREWSBURY SY1 2SYTel: 01743 353371Fax: 01743 271598F645H14826256337C4H8F2C164A467F4767447F88166565765G3F3D3SKEGNESS PE25 3TBTel: 01754 611748Fax: 01754 611752STOKE ST1 5NPTel: 01782 213914Fax: 01782 283502STOKE - JOHNGODDEN ST1 5NPTel: 01782 204224Fax: 01782 283502TELFORD TF1 7GXTel: 01952 605006Fax: 01952 605060WHITEHAVEN CA28 8EATel: 01946 61232Fax: 01946 64253YORK YO30 4WPTel: 01904 693241Fax: 01904 692814WESTABINGDON OX14 1RLTel: 01235 533733Fax: 01235 522047BIRMINGHAM B7 5ETTel: 0121 327 1100Fax: 0121 327 1573BIRMINGHAM -SUNBRIDGE B7 5ETTel: 0121 327 1475Fax: 0121 328 7388BROMSGROVE B60 3EXTel: 01527 558774Fax: 01527 558781CORBY NN17 4AUTel: 01536 201613Fax: 01536 402210COVENTRY CV1 4DWTel: 024 7622 8141Fax: 024 7622 8151DERBY DE24 8EHTel: 01332 755918Fax: 01332 757673HIGH WYCOMBE HP13 6EQTel: 01494 534923Fax: 01494 523914LEICESTER LE4 7STTel: 0116 266 3861Fax: 0116 261 0884LEICESTER -EMS LE1 1QRTel: 0116 262 2588Fax: 0116 251 1429NOTTINGHAM NG2 1AHTel: 0115 986 0111Fax: 0115 986 2841SLOUGH SL1 4HBTel: 01753 525451Fax: 01753 574085WALSALL WS2 7DHTel: 01922 710170Fax: 01922 710143WOLVERHAMPTON WV10 6HHTel: 01902 710333Fax: 01902 710325EASTASHFORD TN24 8EPTel: 01233 631976Fax: 01233 632121BRENTWOOD CM13 1TATel: 01277 223481Fax: 01277 262814CAMBRIDGE CB1 7EATel: 01223 212603Fax: 01223 249136COLCHESTER CO2 8HETel: 01206 797333Fax: 01206 790919EASTBOURNE BN23 6PUTel: 01323 509231Fax: 01323 500430FOLKESTONE CT19 5FGTel: 01303 220904Fax: 01303 220907GRANTHAM NG31 6HNTel: 01476 567377Fax: 01476 590640HASTINGS TN37 7PJTel: 01424 755833Fax: 01424 755426587955H983607761868731388839B2277589A3H7714243A53384C634IPSWICH IP3 0ABTel: 01473 253781Fax: 01473 233032LUTON LU1 1TWTel: 01582 405764Fax: 01582 723445MAIDSTONE ME15 6RQTel: 01622 691250Fax: 01622 692283MAIDSTONE - SUN-BRIDGE ME15 6RQTel: 01622 692662Fax: 01622 661203MILTON KEYNES MK1 1JWTel: 01908 379601Fax: 01908 378736PETERBOROUGH PE1 5YBTel: 01733 561237Fax: 01733 563286SITTINGBOURNE ME10 2PDTel: 01795 439626Fax: 01795 439627SOUTHEND-ON-SEA SS2 5RDTel: 01702 462955Fax: 01702 469579SOUTH WESTBOURNEMOUTH BH12 3LNTel: 01202 739433Fax: 01202 732798BRIDGWATER TA6 5JXTel: 01278 458276Fax: 01278 458287BRIDPORT DT6 4RZTel: 01308 424411Fax: 01308 456111BRISTOL BS3 5SATel: 0117 966 7081Fax: 0117 966 9865CAMBORNE TR14 7TATel: 01209 714441Fax: 01209 711185CARDIFF CF11 8QYTel: 029 2039 7815Fax: 029 2022 4258CHIPPENHAM SN14 6LHTel: 01249 656127Fax: 01249 654122DORCHESTER DT1 2PGTel: 01305 265955Fax: 01305 265957EASTLEIGH SO50 4ZYTel: 023 8068 7768Fax: 023 8068 7769EXETER EX2 8PETel: 01392 434455Fax: 01392 420052FARNHAM GU9 9PRTel: 01252 726100Fax: 01252 714687GLOUCESTER GL4 3SJTel: 01452 332382Fax: 01452 311496GUILDFORD GU2 8YTTel: 01483 569261Fax: 01483 534740MERTHYR TYDFIL CF48 4SRTel: 01685 384343Fax: 01685 376407NEWPORT NP20 5NSTel: 01633 857070Fax: 01633 855875PORTSMOUTH PO3 6FHTel: 023 9282 9021Fax: 023 9286 3557ST. AUSTELL PL25 3JNTel: 01726 61772Fax: 01726 64266SWANSEA SA6 8JGTel: 01792 774002Fax: 01792 774153TREFOREST CF37 5UATel: 01443 843113Fax: 01443 843114WOKING GU21 4PXTel: 01483 740101Fax: 01483 7407757269515268B1A6GREATER LONDONCHESSINGTON KT9 1STTel: 020 8397 9478Fax: 020 8397 4561CHISWICK W4 5PZTel: 020 8996 0304Fax: 020 8742 3860CROYDON CR0 4RRTel: 020 8666 0409Fax: 020 8666 0408EAST HAM E6 6LPTel: 020 7474 2622Fax: 020 7511 3645FOOTSCRAY DA14 5AJTel: 020 8302 0901Fax: 020 8302 4605ISLINGTON N7 9AATel: 020 7609 9941Fax: 020 7700 2143REDHILL RH1 2LPTel: 01737 769055Fax: 01737 7742092850Connect with the BestSTRATFORD E15 2PETel: 020 8555 4653Fax: 020 8522 4173SYDENHAM SE26 5BATel: 020 8778 6042Fax: 020 8778 3307Rexel <strong>Senate</strong> Ltd.<strong>Senate</strong> House, 6-16 Southgate Road, Potters Bar, Hertfordshire. EN6 5DSTel: 01707 640000 Fax: 01707 640111 www.senate.co.uk