<strong>Vickers</strong> ®<strong>General</strong> <strong>Product</strong> <strong>Support</strong><strong>Guide</strong> <strong>to</strong> <strong>Industrial</strong> Hydraulics


Systems capabilities designed <strong>to</strong> help you...The products featured in this catalogrepresent the best in hydraulic andelectrohydraulic technology from acompany that has been a leader in theindustry for over seventy-five years.<strong>Vickers</strong> has a continuing commitment <strong>to</strong>provide its cus<strong>to</strong>mers with qualityproducts and system solutions.This catalog highlights the spectrum of<strong>Vickers</strong> industrial hydraulic products. Itspurpose is <strong>to</strong> provide a convenientreference <strong>to</strong>ol when choosing <strong>Vickers</strong>products or designing a system using<strong>Vickers</strong> components. It is divided in<strong>to</strong>different sections according <strong>to</strong> the typeof product. Each entry gives a briefdescription and basic specifications for aspecific product. Should you requiremore detailed information, the catalognumber for each product is alsoprovided.<strong>Vickers</strong> has the expertise needed <strong>to</strong>provide you with complete fluid powersystem solutions, including the hugeproduct selection previewed onfollowing pages. We also offer in-depthknowledge of your market, andsystem design know-how <strong>to</strong> overcomedesign problems inherent in yourmarket segment.With manufacturing and designlocations around the world, we “speakyour language.” Our engineersunderstand your system needs as wellas regional differences.When you’re challenged <strong>to</strong> provide moreenergy-efficient equipment that mustwork harder than ever before, let ushelp you meet the challenge with: Systems that give you <strong>to</strong>tal power andmotion control management capability Systems with faster control responseand enhanced reliability Systems featuring integral controllogic, sensors, and self-diagnosticsLet one of our dedicated-market teamswork closely with you in your earlypreliminary design stages <strong>to</strong>: Design an optimal power and motioncontrol system. Ensure the performance compatibilityof <strong>Vickers</strong> products with that ofexisting system. Share application knowledge thatallows better support of products –yours and ours – in the field.With every <strong>Vickers</strong> system, you’llreceive support on a global scale...research, development and design;systems application engineering; promptdelivery and expert service. Mostimportant, you’ll get quality in everythingwe do for you.So whether you design, build ormaintain industrial equipment for plasticinjection, machine <strong>to</strong>ol cutting & forming,au<strong>to</strong>motive or primary metals, <strong>Vickers</strong>has dedicated resources <strong>to</strong> serve yourmarket and provides unmatchedexpertise in system reliability.Choose <strong>Vickers</strong> – for “systems thinking”that will maximize the performance ofyour industrial applications. <strong>Vickers</strong>, Incorporated 1998All Rights Reserved


ContentsVane PumpsSingle fixed displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Double fixed displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Variable displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Pis<strong>to</strong>n PumpsFixed displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Variable displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Vane Mo<strong>to</strong>rsFixed displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8High <strong>to</strong>rque, low speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Pis<strong>to</strong>n Mo<strong>to</strong>rsFixed displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Variable displacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Pressure ControlsRemote and standard relief . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Multi-pressure solenoid operated relief valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Sequence, unloading, back pressure, and counterbalance valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Flange mounted relief valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Flange mounted unloading valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Flow ControlsAdjustable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Check Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Cartridge ValvesScrew-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Slip-in <strong>to</strong> ISO 7368 (DIN 24342) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Solenoid controlled, poppet-type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Directional Control ValvesSolenoid operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Solenoid controlled, pilot operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Solenoid controlled, poppet-type, gasket mounted . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Manual, air, or hydraulic, pilot operated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Stacking ValvesSystemStak modular valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Proportional ControlsDirectional and throttle controls, pilot operated, with integral electronics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Directional and throttle controls, with separate drive amplifier/controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Directional controls, without/with electrical feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Electrohydraulic proportional pressure relief valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Auxiliary function modules for proportional valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Electrohydraulic proportional flow control valves (Valvis<strong>to</strong>r) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Servovalves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33ElectronicsAmplifiers and electrical accessories for proportional valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Single-cable connec<strong>to</strong>r (UNIPLUG) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Amplifiers and electrical accessories for servo valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Amplifiers for pressure and flow controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Cylinders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Power PackagesOff-Line Filtration System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41SystemPak and SystemCenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Integrated Mo<strong>to</strong>r Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43Index of Referenced Catalogs and Available Languages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443


Vane pumps: Single fixed displacement<strong>Vickers</strong> offers an extensive line of fixed displacement single pumps with displacementsfrom 3,3 <strong>to</strong> 215 cm 3 /r (.20 <strong>to</strong> 13.12 in 3 /r); continuous pressures <strong>to</strong> 280 bar (4000 psi);speeds <strong>to</strong> 7000 r/min. V10 and V20 models can be provided with integral valving <strong>to</strong> limitflow <strong>to</strong> the operating system, <strong>to</strong> limit maximum system pressure, and <strong>to</strong> divide flowbetween two circuits. VTM42 pumps are for power steering applications. VQ, VMQ andVPF models are available with thru-drives.ModelMaximumDeliveryL/min (USgpm)GeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmCatalogV10 26,5 (7.0) 3,3 (0.2) <strong>to</strong>16,4 (1.4)V20 49,2 (13.0) 19,5 (1.19) <strong>to</strong>42,4 (2.59)20V 79,9 (21.1) 7 (0.43) <strong>to</strong>45 (2.78)25V(T) 118,1 (31.2) 33 (2.0) <strong>to</strong>67 (4.13)35V(T) 213,5 (56.4) 81 (4.94) <strong>to</strong>121 (7.37)35V(T) 213,5 (56.4) 81 (4.94) <strong>to</strong>121 (7.37)45V(T) 344,4 (91.0) 138 (8.41) <strong>to</strong>193 (11.75)25VPF(T) 110,0 (29.3) 10 (0.62) <strong>to</strong>80 (4.88)35VPF(T) 135,0 (8.2) 90 (5.49) <strong>to</strong>135 (8.24)45VPF(T) 118,1 (31.2) 140 (8.54) <strong>to</strong>195 (11.89)25VMQ 133,7 (35.3) 10 (0.62) <strong>to</strong>80 (4.88)35VMQ 230,0 (60.8) 90 (5.49) <strong>to</strong>135 (8.24)Vane pumps: Double fixed displacement175 (2500) 4800 698175 (2500) 3400 698210 (3000) 1800 560175 (2500) 1800 560175 (2500) 1800 560175 (2500) 1800 560175 (2500) 1800 560293 (4250) 1800 708260 (3800) 1800 708260 (3800) 1800 708260 (3800) 1800 5008.00/EN/0596/A260 (3800) 1800 5008.00/EN/0596/A<strong>Vickers</strong> extensive line of fixed displacement double pumps offers: displacements from22,8 <strong>to</strong> 390 cm 3 /r (1.39 <strong>to</strong> 23.78 in 3 /r); continuous pressures <strong>to</strong> 280 bar (4000 psi);speeds <strong>to</strong> 3000 r/min. V2010 and V2020 models can be provided with integral valving <strong>to</strong>limit flow <strong>to</strong> the operating system, <strong>to</strong> limit maximum system pressure, and <strong>to</strong> divide flowbetween two circuits. VQ models are available with thru-drives.ModelMaximumDeliveryL/min (USgpm)Geometric MaximumDisplacement Pressurecm 3 /r (in 3 /r) bar (psi)MaximumSpeedrpmCatalogV201076,6 (20.2)shaft end28,4 (7.5)cover end19,5 (1.19) <strong>to</strong>42,4 (2.59)3,3 (0.2) <strong>to</strong>16.4 (1.0)155 (2250) 1800 698V202076,6 (20.2)shaft end76,6 (20.2)cover end19,5 (1.19) <strong>to</strong>42,4 (2.59)19,5 (1.19) <strong>to</strong>42,4 (2.59)155 (2250) 1800 6984


Vane pumps: Double fixed displacement (continued)ModelMaximumDeliveryL/min (USgpm)GeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmCatalog2520V33,0 (2.0)shaft end7,0 (0.45)cover end67 (4.1)shaft end45 (2.8)cover end175 (2500)210 (3000)1800 5602525V79,5 (21.0)shaft end53,0 (14.0)cover end67 (4.1)shaft end67 (4.1)cover end175 (2500)175 (2500)1800 5603520V213,5 (56.4)shaft end79,9 (21.1)cover end121 (7.4)shaft end45 (2.8)cover end175 (2500)210 (3000)1800 5603525V213,5 (56.4)shaft end118,1 (31.2)cover end121 (7.4)shaft end67 (4.1)cover end175 (2500)175 (2500)1800 5604520V344,4 (91.0)shaft end79,9 (21.1)cover end193 (11.7)shaft end45 (2.8)cover end175 (2500)210 (3000)1800 5604525V4535V344,4 (91.0)shaft end118,1 (31.2)cover end344,4 (91.0)shaft end213,5 (56.4)cover end193 (11.7)shaft end67 (4.1)cover end193 (11.7)shaft end121 (7.4)cover end2525VMQ 133,7 (35.3) 80 (4.88)shaft end80 (4.88)cover end3525VMQ 230,0 (60.8) 135 (8.24)shaft end80 (4.88)cover end175 (2500)175 (2500)175 (2500)175 (2500)260 (3800)260 (3800)230 (3300)260 (3800)1800 5601800 5601800 5008.00/EN/0596/A1800 5008.00/EN/0596/A2525VPF 135,0 (35.6)80 (4.88)shaft end80 (4.88)cover end175 (2500)175 (2500)1800 7083525VPF 230,0 (60.8) 135 (8.24)shaft end80 (4.88)cover end3535VPF 230,0 (60.8) 135 (8.24)shaft end135 (8.24)cover end262 (3800)293 (4250)262 (3800)262 (3800)1800 7081800 7085


Vane pumps: Double fixed displacement (continued)ModelMaximumDeliveryL/min (USgpm)GeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmCatalog4525VPF 331,2 (87.5) 195 (11.89)shaft end80 (4.88)cover end4535VPF 331,2 (87.5) 195 (11.89)shaft end135 (8.24)cover end4545VPF 331,2 (87.5) 195 (11.89)shaft end195 (11.89)cover endVane pumps: Variable displacement262 (3800)293 (4250)262 (3800)262 (3800)262 (3800)262 (3800)1800 7081800 7081800 708VVA pumps are pressure compensated variable displacement vane pumps havingseparate adjustments for pressure compensation and maximum displacement. Pressurecompensa<strong>to</strong>r options include single and dual adjustable pressure designs. VVB pumpsare offered with a wide choice of energy-saving pressure and/or flow sensitive controls.The range covers internally and externally signalled types.ModelMaximumDeliveryL/min (USgpm)GeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmCatalogVVA 100 (24,4) 83 (5.06) 100(1500)1800 GB-V-117Pis<strong>to</strong>n Pumps: Fixed displacementVVB 90 (23,8) 50 (3.05) 220 (3250) 1800 GB-2342PFB fixed displacement pis<strong>to</strong>n pumps are available in four geometric displacements:10,5; 21,1; 42,8 and 94,4 cm 3 /rev (0.64, 2.61 and 5.76 in 3 /rev). Depending upondisplacement and type of fluid used, maximum speeds are from 1200 <strong>to</strong> 3600 r/min,and maximum operating pressures are from 69 <strong>to</strong> 207 bar (1000 <strong>to</strong> 3000 psi). Footmountings are available for all models.ModelMaximumDeliveryL/min (USgpm)GeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmCatalogPFB5PFB10PFB20PFB4538 (10) 10,5 (0.64) 210 (3000) 3600 658GB-2379B68 (18) 21 (1.29) 210 (3000) 3200 658GB-2379B75 (19.9) 42,8 (2.61) 175 (2500) 2400 658GB-2379B27 (54) 94,4 (5.76) 210 (3000) 2200 658GB-2379B6


Pis<strong>to</strong>n Pumps: Variable displacementVariable displacement pis<strong>to</strong>n pumps can closely match pressure and/or flow demandwith operating pressure up <strong>to</strong> 270 bar (3900 psi). The pumps are available in geometricdisplacements from 10,5 <strong>to</strong> 197,3 cm 3 /r (0.64 <strong>to</strong> 12 in 3 /r) with drive speeds up <strong>to</strong> 1800rpm. A variety of controls provides the ability <strong>to</strong> match the pumps <strong>to</strong> each application.Options include: pressure compensa<strong>to</strong>r with or without a remote control facility; pressurecompensa<strong>to</strong>r with adjustable displacement control; load sensing compensa<strong>to</strong>r;mechanical control; and handwheel control.ModelMaximumDeliveryL/min (USgpm)GeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmCatalogPVB5PVB6PVB10PVB15PVB20PVB29PVB45PVB9018,9 (5.0)22,7 (6.0)37,5 (10.0)59,4 (15.7)75,7 (20.0)109,7 (29.0)170,3 (45.0)348 (91.9)10,5 (0.64)13,8 (0.84)21,1 (1.29)33,0 (2.01)42,8 (2.61)61,6 (3.76)94,5 (5.76)197,5 (12.04)210 (3000)140 (2000)210 (3000)140 (2000)210 (3000)140 (2000)210 (3000)210 (3000)1800 GB-2379BPVH45 81 (21) 45,1 (2.75) 350 (5000) 1800 5016/EN/1196/APVH131 215 (57) 131,1 (8.00) 350 (5000) 1800 5016/EN/1196/APVH57QI 98 (28) 57,4 (3.5) 250 (3600) 1800 GB-C-2010PVH74QI 125 (33) 73,7 (4.5) 250 (3600) 1800 GB-C-2010PVH98QI 170 (45) 98,3 (6) 250 (3600) 1800 GB-C-2010PVH131QI 223 (59) 131,1 (8) 250 (3600) 1800 GB-C-2010PVQ10 18,6 (4.9) 10,5 (0.64) 210 (3000) 1800 GB-C-2132PVQ13 24,1 (6.4) 13,8 (0.84) 140 (2000) 1800 GB-C-2132PVQ16 27,9 (7.4) 16 (0.9) 210 (3000) 1800 GB-C-2132PVQ20 37,0 (9.8) 21,1 (1.29) 210 (3000) 1800 GB-C-2132PVQ25 46,0 (12.2) 25,2 (1.54) 210 (3000) 1800 GB-C-2132PVQ32 58 (15.3) 32,9 (2.01) 140 (2000) 1800 GB-C-2132PVQ40 72,3 (19.1) 41 (2.5) 210 (3000) 1800 GB-C-2132PVQ45 80,0 (21.0) 45,1 (2.75) 190 (2700) 1800 GB-C-2132PVQ50 88 (23) 50 (3.05) 270 (3900) 1800 5014.00/EN/0297/APVQ63 111,0 (29.3) 63 (3.84) 210 (3000) 1800 GB-C-2132PVQ141 249 (66) 141,1 (8.64) 270 (3900) 1800 5014.00/EN/0297/A7


Vane mo<strong>to</strong>rs: Fixed displacement<strong>Vickers</strong> vane mo<strong>to</strong>rs offer: displacements from from 21,6 <strong>to</strong> 317,1 cm 3 /r(1.32 <strong>to</strong>19.35 in 3 /r); pressures <strong>to</strong> 175 bar (2500 psi); speeds <strong>to</strong> 4000 r/min; a choiceof 15 <strong>to</strong>rque ratings.ModelGeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmTheoreticalTorqueNm/∆ 7 bar(lb. in./∆100 psi)CatalogM2 24,7-35,4(1.51-2.16)25M 43-69(2.68-4.19)35M 84-122(5.10-7.44)45M 138-193(8.42-11.79)50M 231-317,09(14.11-19.32)Vane mo<strong>to</strong>rs: High <strong>to</strong>rque, low speed140 (2000) 2200 2,8-4,1(25-36)175 (2500) 4000 4,7-7,3(42-65)175 (2500) 4000 9,04-13(80-115)175 (2500) 4000 14,68-20,9(130-185)155 (2250) 3200 24,8-33,9(220-300)674674674674674<strong>Vickers</strong> high <strong>to</strong>rque, low speed vane mo<strong>to</strong>rs offer: displacements from 24 <strong>to</strong> 754 cm 3 /r(393 <strong>to</strong> 12356 in 3 /r); pressures <strong>to</strong> 280 bar (4000 psi); speeds <strong>to</strong> 400 r/min; a choice of 14single <strong>to</strong>rque, single displacement models or 12 multi-<strong>to</strong>rque, multi-displacement models.ModelGeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmTheoreticalTorqueNm/∆ 7 bar(lb. ft./∆100 psi)CatalogMHT32 393 (24) 210 (3000) 400 43 (32) 679MHT50 623 (38) 280 (4000) 350 68 (50) 679MHT70 865 (52.8) 210 (3000) 300 95 (70) 679MHT130 1852 (113) 280 (4000) 200 176 (130) 679MHT150 1852 (113) 280 (4000) 250 203 (150) 679MHT220 2720 (166) 190 (2750) 200 298 (220) 679MHT-250 3137 (188) 190 (2750) 200 339 (250) 679MHT-375 4638 (283) 190 (2750) 100 508 (375) 679MHT-380 4806 (288) 190 (2750) 200 515 (380) 679MHT-440 5440 (332) 190 (2750) 200 597 (440) 679MHT500 6274 (376) 190 (2750) 200 678 (500) 6798


Vane mo<strong>to</strong>rs: High <strong>to</strong>rque, low speed (continued)ModelGeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmTheoreticalTorqueNm/∆ 7 bar(lb. ft./∆100 psi)CatalogMHT-750 9258 (565) 190 (2750) 100 1017 (750) 679MHT-1000 12356 (754) 190 (2750) 100 1356 (1000) 679MHT70/35/35868 & 426(53 & 26)280 (4000) 300 95 & 47(70 & 35)679MHT90/45/451114 & 540(68 & 33)280 (4000) 300 122 & 61(90 & 45)679MHT190/95/9572 & 144(1180 & 2360)190 (2750) 200 129 & 258(95 & 190)679MHT220/125/9572 & 94 &166(1180 &1377 &2720)190 (2750) 200 129 & 170 & 298(95 & 125 & 220)679MHT250/125/1251540 & 3081(94 & 188)Pis<strong>to</strong>n mo<strong>to</strong>rs: Fixed displacement190 (2750) 200 170 & 339(125 & 250)679<strong>Vickers</strong> pis<strong>to</strong>n mo<strong>to</strong>rs offer: fixed displacements from 10,5 <strong>to</strong>160 cm 3 /r (.64 <strong>to</strong> 9.76 in 3 /r)and variable displacements from 41 <strong>to</strong> 355 cm 3 /r (2.5 <strong>to</strong> 21.66 in 3 /r); continuouspressures <strong>to</strong> 480 bar (6960 psi); speeds <strong>to</strong> 3600 r/min. MFE and MVE models are idealfor use with <strong>Vickers</strong> TA19 and TA1919 hydrostatic transmission pumps.ModelGeometricDisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmTheoreticalTorqueNm/∆ 7 bar(lb. in./∆100 psi)CatalogMFB5 10,53 (0.643) 210 (3000) 3600 1,15 (10.2) 691MFB10 21.14 (1.29) 210 (3000) 3200 2,3 (20.5) 691MFB20 42.77 (2.61) 175 (2500) 2400 4,7 (41.6) 691MFB29 61.6 (3.76) 140 (2000) 2400 6,76 (59.9) 691MFB45 94.4 (5.76) 210 (3000) 2200 10,3 (91.7) 691MFE15 32,77 (2) 350 (5000) 3600 3,6 (31.8) 691MFE19 40,96 (2.5) 350 (5000) 3600 4,5 (39.8) 6919


Pis<strong>to</strong>n mo<strong>to</strong>rs: Variable displacement<strong>Vickers</strong> variable displacement pis<strong>to</strong>n mo<strong>to</strong>rs offer: two displacements of 19,5 and 21,1cm 3 /r (0.64 and 1.29 in 3 /r); flows from 19,0 <strong>to</strong> 68,1 l/min (5.0 <strong>to</strong> 18.0 USgpm); speed rangesdependent on input flow and displacement control with a range of 4:1 <strong>to</strong> 12:1. MVB5 andMVB10 mo<strong>to</strong>rs will operate at speeds as low as 50 rpm with appropriate circuit andapplication considerations.ModelGeometricdisplacementcm 3 /r (in 3 /r)MaximumPressurebar (psi)MaximumSpeedrpmTheoretical<strong>to</strong>rqueNm/∆ 7 bar(lb. in./∆100 psi)CatalogMVB5 10,53 (0.64) 210 (3000) 3600 1,15 (10.2) 691MVB10 21,14 (1.29) 210 (3000) 3200 2,3 (20.5) 691MVE19 40,96 (2.5) 350 (5000) 4000 4,5 (39.8) 691Pressure Controls: Remote and standard reliefSmall, easily installed remote pressure control valves make it possible <strong>to</strong> control abalanced pis<strong>to</strong>n pressure relief valve from a more convenient location. Availablepressure ranges for the CGR-02 valve are from 4,5 <strong>to</strong> 70 bar (65 <strong>to</strong> 1000 psi), from 4,5 <strong>to</strong>140 bar (65 <strong>to</strong> 2000 psi), and from 4,5 <strong>to</strong> 210 bar (65 <strong>to</strong> 3000 psi).Pressure relief valves mount between the pump and valve system <strong>to</strong> protect fromoverloads. A sensitive adjustment mechanism allows the setting of the pressure in fineincrements over a wide range - up <strong>to</strong> the maximum rating of the valve. Availablepressure ranges for these valves are from 5 <strong>to</strong> 70 bar (75 <strong>to</strong> 1000 psi) <strong>to</strong>100 <strong>to</strong> 210 bar(1500 <strong>to</strong> 3000 psi). Maximum flows are <strong>to</strong> 680 l/min (180 USgpm).Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogC-175 Manual adjustment 1 / 4 ” 210 (3000) 12 (3) 5110.00/EN/1297/AGB-411ACG-03Balanced pis<strong>to</strong>n type,adjustable03 210 (3000) 30 (8) 5110.00/EN/1297/AVentCG-19Solenoidcontrolled,pilot operated0610210 (3000) 340 (90)680 (180)5110.00/EN/1297/AP10


Pressure controls: Remote and standard relief (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogCG2V-6CG2V-8CG5V-6CG5V-8Two-stage withintegral manual adj.Two-stage withintegral manual adj.Two-stage with sol.operated pilotTwo-stage with sol.operated pilot06 350 (5000) 400 (106) GB-2323A080608CGE-02CGE-06CGE-10Manifold or subplatemounted, remoteelectricallymodulated020610210 (3000) 380 (100) 5110.00/EN/1297/ACGR-02Remote control forrelief valves. Not foruse as independentrelief valve. Manualadjustment02 210 (3000) Pilot flow 5110.00/EN/1297/AGB-409APTCS/T-03CS/T*-06CS/T*-10Balanced pis<strong>to</strong>n typew/optionalsequence feature030610210 (3000) 170 (45)340 (90)681 (180)5110.00/EN/1297/AECT-06Two-stage, pipemounted06250 (3600) 200 (53)GB-C-2330AECT-10Two-stage, pipemounted10380 (100)11


Pressure controls: Multi-pressure solenoid operated relief valvesBalanced pis<strong>to</strong>n-type valves are used in applications needing an electrically orpneumatically controlled adjustable pressure relief or regulating valve <strong>to</strong> limit thepressure in a hydraulic circuit <strong>to</strong> the desired maximum.Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogCG(H)-06CG(H)-10Balanced pis<strong>to</strong>n typew/optionalsequence feature0610210 (3000) 340 (90)681 (180)5110.00/EN/1297/ACG/S/T-19-03CG/S/T-19-06CG/S/T-19-10Air controlled,pilot operated030610210 (3000) 227 (60)340 (90)680 (180)5110.00/EN/1297/APTbCG/S/T-06-DGCG/S/T-10-DGMulti-pressure,with DG4S4-01pilot valve0610210 (3000) 340 (90)680 (180)5110.00/EN/1297/ACG/S/T-06-DGCG/S/T-10-DGMulti-pressure,with DG4V-3pilot valve0610210 (3000) 340 (90)680 (180)5110.00/EN/1297/ACG5-06CG5-10Multi-pressure,solenoid controlled0610210 (3000) 171 (45)380 (90)5110.00/EN/1297/A12


Pressure controls: Sequence, reducing, unloading, back pressure andcounterbalance valves<strong>Vickers</strong> R-series ‘‘hydrocushion’’ type pressure control valves are used <strong>to</strong> control thesequencing, unloading, back pressure, and counterbalancing of oil flow. R(C)T andR(C)S have an optional pressure inlet so they may be mounted in-line. UR and EURseries unloading relief valves contain an integral check valve which prevents return flowfrom the accumula<strong>to</strong>r through the unloading valve. X series pressure reducing valvesoperate under the theory of the reduced outlet pressure remaining constant regardless ofvariation of inlet pressure above the pressure setting.Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogEURG-1/2-06EURG-1/2-10Unloading relief,subplate mounted0610210 (3000) 95 (25)246 (65)GB-404AEURT-1/2-06EURT-1/2-10Unloading relief,line mounted0610210 (3000) 76 (20)189 (50)GB-404AR(C)G/S/T-03R(C)G/S/T-06R(C)G/S/T-10R(C)G/S/T-12Sequence,unloading, backpressure, andcounterbalance,subplate or linemounted03061012210 (3000) 45 (12)114 (30)284 (75)284 (75)686URG-06URG-10Unloading relief,subplate mounted0610210 (3000) 95 (25)246 (65)686URT-06URT-10Unloading relief,line mounted0610210 (3000) 76 (20)189 (50)686XSL/XTL-03Pressure reducing,line mounted3 / 8 ” 140 (2000) 31 (8) 686XGL-03Pressure reducing,subplate mounted03 140 (2000) 31 (8)68613


Pressure controls: Sequence, reducing, unloading, back pressure andcounterbalance valves (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogX(C)*/S/T-03X(C)*/S/T-06X(C)*/S/T-10Pressure reducing,w/optional integralcheck, line orsubplate mounted030610210 (3000) 114 (30)265 (70)530 (140)686X(C)G2V-6X(C)G2V-8Pressure reducing,w/optional integralcheck, line orsubplate mounted0608350 (5000) 200 (53)300 (80)GB-C-2321AXF-16Reducing, linemounted, flangeports1 1 / 2 ”or 2”210 (3000) 473 (125) I-135010XCF-16Reducing valvew/integral check, linemounted, flangeportsPressure controls: Flange mounted valves2” 210 (3000) 473 (125) I-135011Flange mounted valves mount directly <strong>to</strong> the pump flange and reduce potential leakpoints for superior leak resistance. Three different valves are available: relief, unloadingand check. Pilot design minimizes response time and cracking flow which allows for highpressure stability and increased system productivity.Port size: 06 - 3/4” flange; 08 - 1” flange; 10 - 1-1/4” flange; 12 - 1-1/2” flange.Maximum pressure 350 bar (5000 psi); maximum flow 600 l/min (160 USgpm).Model Description NomSizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogCPF1S-06Single pressure,without vent06 280 (4000) 100 (26) 627CPF1S-08CPF1S-10Single pressure,without ventSingle pressure,without vent08 280 (4000) 300 (80)10 280 (4000) 600 (160)CPF1S-12Single reliefwithout vent12 280 (4000) 600 (160)CPF1V-12Single reliefwithout vent12 350 (5000) 600 (160)14


Pressure controls: Flange mounted valves (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min(USgpm)CatalogCPF2S-06CPF2S-08CPF2S-10CPF2S-12CPF2V-12CPF3S-06Single pressure,with ventSingle pressurewith ventSingle pressurewith ventSingle pressurewith ventSingle pressurewith ventBi-pressure w/max.press. override06 280 (4000) 100 (26) 62708 280 (4000) 300 (80)10 280 (4000) 600 (160)12 280 (4000) 600 (160)12 350 (5000) 600 (160)06 280 (4000) 100 (26) 627CPF3S-08Bi-pressure w/max.press. override08 280 (4000) 300 (80)CPF3S-10Bi-pressure w/max.press. override10 280 (4000) 600 (160)CPF3S-12CPF3V-12CPF4S-06Bi-pressure w/ max.press. overrideBi-pressure w/max.press. overrideTri-pressure w/max.press. override12 280 (4000) 600 (160)12 350 (5000) 600 (160)06 280 (4000) 100 (26) 627CPF4S-08Tri-pressure w/max.press. override08 280 (4000) 300 (80) 627CPF4S-10CPF4S-12CPF4V-12Tri-pressure w/max.press. overrideTri-pressure w/max.press. overrideTri-pressure w/max.press. override10 280 (4000) 600 (160) 62712 280 (4000) 600 (160) 62712 350 (5000) 600 (160) 627DCPFS-08-20DCPFS-10-20DCPFS-12-20Mtg. on pump flangeor stacked w/CPFrelief valves; poppetdesign280 (4000) 114 (30)227 (60)378 (100)62715


Pressure controls: Flange mounted unloading valvesThe <strong>Vickers</strong> UPF unloading valve features flange mounting for increased designflexibility and reduced external piping. The valve is designed for direct mounting on theSAE flange outlet port of a pump. The UPF1 (without vent) and UPF2 (with vent) haveflow ratings <strong>to</strong> 600 l/min (160 USgpm) and maximum pressure up <strong>to</strong> 210 bar (3000 psi).Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogUPF1S-06UPF1S-08UPF1S-10UPF1S-12UPF1V-12UnloadingUnloadingUnloadingUnloadingUnloading0608101212280 (4000)280 (4000)280 (4000)280 (4000)350 (5000)100 (26)300 (80)600 (160)600 (160)600 (160)627UPF2S-06UPF2S-08UPF2S-10UPF2S-12UPF2V-12Unloading w/ventUnloading w/ventUnloading w/ventUnloading w/ventUnloading w/vent0608101212280 (4000)280 (4000)280 (4000)280 (4000)350 (5000)100 (26)300 (80)600 (160)600 (160)600 (160)627Flow Controls: Adjustable<strong>Vickers</strong> temperature and pressure compensated flow controls allow precise volumetriccontrol. These valves are available with (bypass type) or without (restric<strong>to</strong>r type) integralrelief valves and are suitable for pressures up <strong>to</strong> 250 bar (3600 psi).FN and EFN (regula<strong>to</strong>r) valves are suited for applications requiring flow regulationwithout pressure compensation. F(C)G (restric<strong>to</strong>r) valves are pressure compensated <strong>to</strong>provide precise adjustable flow rate, regardless of load pressure or temperature changes.FRG (bypass) valves are pressure and temperature compensated and also provideprecise adjustable flow rates, regardless of load pressure or temperature changes.Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogEFN-06EFN-10Flow regula<strong>to</strong>rwithout pressurecompensation, linemounted0610210 (3000) 76 (20)189 (50)GB-2339AFN-03FN-06FN-10Flow regula<strong>to</strong>rwithout pressurecompensation, linemounted030610210 (3000) 38 (10)76 (20)189 (50)685FN-4Flow regula<strong>to</strong>r,non-compensated140 (2000) 9 (2.4) GB-2278AF(C)G-02Flow regula<strong>to</strong>r,press. and temp.compensated,subplate mounted02 250 (3600) 38 (10) 68516


Flow Controls: Adjustable (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogF(C)G-03Flow regula<strong>to</strong>r,pressure andtemperaturecompensated,subplate mounted03 210 (3000) 106 (28) 685FG-06FG-10Flow regula<strong>to</strong>r,pressure andtemperaturecompensated,subplate mounted0610140 (2000) 227 (60)375 (99)I-513700FRG-03Flow Controls: Check valvesMeter-in type,pressure andtemperaturecompensated,subplate mounted03 210 (3000) 144 (28) 685<strong>Vickers</strong> inline, right-angle, and manifold mounted check valves are direct operated andused in hydraulic circuits <strong>to</strong> allow the free flow of fluid in one direction only.Inline check valves can be used as a safety bypass for flow surges. Right angle checkvalves are designed for higher flows with less pressure drop. Pilot operated valvespermit reverse flow when a pilot pressure signal is applied <strong>to</strong> the valve’s pilot port. PCGseries operate as direct check valves but can be opened by pilot pressure <strong>to</strong> permit freereverse flow.Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogC2-800C2-805C2-815C2-820C2-825C2-830C2-835High velocityservice, linemounted1 4 ”3 / 8 ”3 / 4 ”1”1 1 / 4 ”1 1 / 2 ”2”210 (3000) 12 (3)22 (6)61 (16)106 (28)170 (45)246 (65)380 (100)645C5G-805C5G-815C5G-825High velocityservice, subplate, ormanifold mounted3 / 8 ”3 / 4 ”1 1 / 4 ”210 (3000) 38 (10)76 (20)379 (100)645DS/T8P1-02DS/T8P1-03DS/T8P1-06DS/T8P1-10Non-shockservice, linemounted1 4 ”3 / 8 ”3 / 4 ”1 1 / 4 ”210 (3000) 12 (3)30 (8)76 (20)190 (50)645PCGV-6PCGV-8Remote pilo<strong>to</strong>perated0608350 (5000) 150 (40)300 (80)GB-2329APCG5V-6PCG5V-8Solenoid pilo<strong>to</strong>perated0608350 (5000) 150 (40)300 (80)GB-2329A4CG/T/S-034CG/T/S-064CG/T/S-10Pilot operated, lineor subplate mounted030610210 (3000) 45 (12)114 (30)284 (75)64517


Cartridge Valves: Screw-in<strong>Vickers</strong> screw-in cartridge valves provide many advantages over traditional hydraulicvalves. While offering the same control functions as traditional hydraulic valves, screw-incartridge valves are compact, reliable, and economical. The concept of combiningmultiple cartridge valves in a common manifold offers the user substantial cost-savingadvantages that cannot be achieved with traditional valving.Our selection of screw–in cartridge valves includes:– Solenoid operated directional controls – Flow controls– Directional controls – Check valves– Proportional controls – Logic elements– Pressure controls – Load controls– Circuit makersModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogADV1-16Pressure controls:Accumula<strong>to</strong>r dischargevalve16 210 (3000) 30 (8) 725CBV*-10CBV*-12CBV7-10CBV*-10Counterbalance 10121010350 (5000)350 (5000)280 (4000)350 (5000)60 (15)114 (30)60 (15)60 (15)722CV3-8CV*-10CV11-12CV1-16CV2-20Check valves:Direct operated810121620350 (5000)350 (5000)350 (5000)210 (3000)210 (3000)30 (8)76 (20)114 (30)151 (40)227 (60)720DPC1-10DPC1-16DPC1-20Check valves:Pilot operated, doubleacting101620210 (3000)210 (3000)210 (3000)45 (12)151 (40)227 (60)720DPS2-10DPS2-16DPS2-20Logic Elements:Differential pressuresensing valve101620Spooltype:290 (4200)Poppettype:240 (3500)60 (15)190 (50)300 (80)724DSV*-6DSV*-8DSV*-10DSV3-12DSV*-16Directional controls:Shuttle valves, non-solenoid68101216210 (3000)240 (3500)350 (5000)210 (3000)210 (3000)11 (3)26 (7)26 (7)90 (24)170 (45)721E*V-10E*V-16Proportionalcontrols1016210 (3000)280 (4000)60 (15)160 (42)72618


Cartridge Valves: Screw-in (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogEPRV2-8EPRV1-10EPRV1-16Proportionalcontrols08101635 (500) 7,6 (2.0)7,6 (2.0)38,0 (10.0)726FCV*-10FCV*-12FCV*-16FCV*-20Flow controls 10121620210 (3000)350 (5000)210 (3000)210 (3000)45 (12)114 (30)208 (55)567 (150)723FDC*-10FDC*-16FDC*-20Flow controls 101620210 (3000) 68 (18)178 (47)567 (150)723FR5-8FR*-10FR*16FR1-20Flow controls 8101620350 (5000)350 (5000)210 (3000)210 (3000)10 (2.5)38 (10)113 (30)227 (60)723MCV*-16MCV*-20Load controls:Counterbalance valves1620210 (3000) 151 (40)190 (50)722MOS1-10MOS1-16Logic Elements:Spool type modulatingorifice cartridges1016210 (3000) 38 (10)132 (35)724MPV1-10Directional controls:Manually operated10 210 (3000) 45 (12) 721MRV*-10MRV*-16Directional controls:Manually operated1016210 (3000) 23 (6)64 (17)721MRV2-10MRV2-16Flow controls:Restric<strong>to</strong>rs, knob/lever1016210 (3000) 57 (15)170 (45)723NV1-8NV1-10NV1-16NV1-20Flow controls:Restric<strong>to</strong>rs, adjustable8101620350 (5000)210 (3000)210 (3000)210 (3000)45 (12)45 (12)151 (40)265 (70)723PCS*-10PCS*-16PCS*-20Logic Elements:Hydrostats101620210 (3000) 38 (10)114 (30)189 (50)72419


Cartridge Valves: Screw-in (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogPFR5-8PFR*-10PFR*-16Flow controls:Pressure compensated81016350 (5000)350 (5000)210 (3000)15 (4)57 (15)151 (40)723POC1-10POC1-12Pilot operated check 1012350 (5000) 60 (15)114 (30)722F TypeS TypePRV*-10PRV*-12PRV2-16Pressure controls:Reducing & relieving101216350 (5000)350 (5000)415 (6000)45 (12)114 (30)151 (40)725PSV*-8PSV*-10PSV11-12PSV1-16Pressure controls:Sequence valves8101216350 (5000)380 (5500)350 (5000)415 (6000)23 (6)23 (6)114 (30)95 (25)725PTS*-10PTS*-16PTS*-20Non-Solenoid Valves 101620210 (3000) 30 (8)132 (35)265 (70)721PUV3-10Pressure controls:Unloading valves10 210 (3000) 4 (1) 725RV*-8RV*-10RV11-12RV5-16Pressure controls:Relief valves8101216350 (5000)350 (5000)350 (5000)415 (6000)30 (8)114 (30)114 (30)303 (80)725SBV11-8SBV11-10SBV11-12Bi-directionalcontrols81012350 (5000) 60 (15)76 (20)114 (30)5082.00/EN/0397/ASPC2-8SPC*-10SPC1-16SPC1-20Check valves:Pilot operated, singleacting8101620240 (3500)210 (3000)210 (3000)210 (3000)19 (5)45 (12)151 (40)227 (60)720SV*-8SV*-10SV*-12SV*-16SV*-20Solenoid Valves 810121620210 (3000) 23 (6)45 (12)114 (30)132 (35)227 (60)727SV**-8SV**-10SV**-12SV**-16SV**-20350 Bar Solenoid Valves 810121620350 (5000) 38 (10)45 (12)114 (30)132 (35)227 (60)72820


Cartridge Valves: Screw-in (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogVCB1-10VCB1-12Load controls:Counterbalance valves1012350 (5000) 60 (15)114 (30)722VF1-10VF1-16VF1-20Velocity fuses 101620210 (3000) 23 (6)114 (30)227 (60)723VRV11-12Pressure controls:Relief valves12 210 (3000) 114 (30) 725CRVFCFRCPCC1PCC2PFRRRGVRLVSCRSRVCircuit Makers 210 (3000) 300 (80)190 (50)190 (50)228 (60)228 (60)152 (40)114 (30)114 (30)114 (30)300 (80)73721


Cartridge Valves: Slip-in <strong>to</strong> ISO 7368 (DIN 24342)Cartridge valves are generally used in medium <strong>to</strong> high pressure hydraulic systemswhere flows may be greater than 150 L/min (40 USgpm), <strong>to</strong> provide powertransmission and motion control in a wide variety of applicationsThe HFV (Hydraulic Feedback Valvis<strong>to</strong>r) range of slip-in cartridge valves uses aself-regulating hydraulic design for the control of flow rate by a current-controlledPWM signal. The design achieves servo-type control of the main poppet withoutusing an electrical feedback transducer.Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USpgm)CatalogCVCS-**-A*/B/D*/N/PC/W**Check,directional& flow restric<strong>to</strong>r162532405063350 (5000) 200 (50)450 (120)700 (200)1100 (300)1700 (450)2800 (750)5043.00/EN/0496/ACVCS-**-CPressure relief,unloading andventing16253240350 (5000) 200 (50)450 (120)700 (200)950 (250)5043.00/EN/0496/ACVCS-**-CO251:0.25 arearatio, lowpressurerelief/directional162532405043.00/EN/0496/ACVCS-**-HFVValvis<strong>to</strong>rProportionalThrottle <strong>to</strong> ISO7368162532405063350 (5000) 175 (46)405 (107)630 (166)810 (214)1305 (345)2160 (571)5043.00/EN/0496/ACVCS-**-ODNormally openprefill253240635043.00/EN/0496/AX ACVCS-**-U* Pressureunloading andreliefY16253240350 (5000) 165 (45)300 (80)420 (110)750 (200)5043.00/EN/0496/ACVCS-**-X(*)Pressurereducer1625350 (5000) 200 (50)400 (106)5043.00/EN/0496/A22


Cartridge Valves: Slip-in <strong>to</strong> ISO 7368 (DIN 24342) (continued)Model Description Nom.Size/TypeMaximumPressurebar (psi)MaximumFlow L/min(USpgm)CatalogCVCS-**-ZD*(N)Dynamicfunctions162532405063350 (5000) 230 (61)550 (145)850 (225)1200 (317)1800 (476)3000 (793)5043.00/EN/0496/ACVU-**-EFP1Electrohydraulicproportionalthrottle16253240315 (4560) 190 (50)450 (120)700 (185)900 (238)5043.00/EN/0496/AXCVU-**(*)SWD(*)Directional withElectricalIndica<strong>to</strong>rsCartridge valves: Solenoid controlled, poppet-type162532405063310 (4500) 210 (55)400 (105)600 (158)900 (236)1600 (420)2500 (660)5043.00/EN/0496/AModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USpgm)CatalogCVUA–6–PD Two- or three-way 315 (4570) 20 (5.3) GB-642A23


Directional control valves: Solenoid operated<strong>Vickers</strong> offers a complete line of mobile directional control valves designed for flexibility, easyapplication and performance. These valves come in various sizes and opera<strong>to</strong>rs... solenoid, hydraulic,air, cam or lever <strong>to</strong> meet a wide range of applications. A soft shift feature is designed <strong>to</strong> providesmoother control of actua<strong>to</strong>r acceleration and deceleration. The electrically actuated valves useindustry- standard connec<strong>to</strong>rs <strong>to</strong> make installation and replacement easier and faster. Our valves usemany common connec<strong>to</strong>rs such as...Packard Weatherpak, DIN, Amp and Deutsche (single & doublespade). Surge suppression is available as standard on applicable valves.These valves are designed <strong>to</strong> optimize equipment performance with operating pressures up <strong>to</strong>350 bar (5000 psi) and flows <strong>to</strong> 1100 l/min (290 USgpm)aABbModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogPTDG3V-5DG3V-7Two or four-way,wet armatureTwo- or four-way,wet armature03 315 (3570) 160 (42) GB-2047A07 350 (5000) 300 (80) GB-2326BDG3V-8 Four-way 08 350 (5000) 700 (185) 5007.02/EN/1196/ADG3V-10 Four-way 10 350 (5000) 1100 (290) 5007.01/EN/0196/ADG4S*-01-50DG4S*-01-60DG4S4-01-60-S491DG4V4-01DG4V-3Two- or four-way,air gapTwo- or four-way,wet armatureTwo- or four-way,wet armature,soft shiftTwo- or four-way,wet armatureTwo or four-way,wet armature05 210 (3000) 76 (20) 67105 250 (3600) 95 (25) GB-C-212905 210 (3000) 76 (20) 61505 315 (4570) 115 (30) 5050.00/EN/0596/A03 350 (5000) 80 (21) 5059.00/EN/1097/ADG4V-3(S)-2Soft shift,wet armature03 350(5000)40 (10) 614DG4V-5Two- or four-way,wet armature05 315 (4570) 115 (30) 5069.00/EN/0497/A24


Directional control valves: Solenoid controlled, pilot operatedaA BbModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogP TDG5S4-02 Four-way 05 210 (3000) 115 (30) GB-C-2037DG5S-8Four-way08210 (3000)380 (100)591DG5S-(H)8Four-way08310 (4500)530 (140)591DG5S4-10 Four-way 10 210 (3000) 946 (250) 669DG5V-5 Four-way 05 315 (4570) 160 (42) GB-2047BDG5V-7 Four-way 07 350 (5000) 300 (80) GB-2326ADG5V-8 Four-way 08 350 (5000) 700 (185) 5007.02/EN/0196/ADG5V-10 Four-way 10 350 (5000) 1100 (290) 5007.01/EN/0197/ADirectional control valves: Solenoid controlled, poppet-type, gasket mounted Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlowL/min (USgpm)CatalogDG3/4VP-3 Three- or four-way 03 315(4570)20 (5.3) GB-642ADirectional control valves: Manual, air, or hydraulic operatedModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogDG2V-2DG4V-2DG17V-2DG21V-2Roller/cam operatedSolenoid operatedLever operatedPlunger operated02 250 (3600) 30 (8) 5018/EN/0596/A25


Directional control valves: Manual, air, or hydraulic operated (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogDG3V-3DG17V-3DG20V-3DG18V-3Hydraulic operatedCam operatedLever operatedAir operated03030303350 (5000)350 (5000)350 (5000)350 (5000)76 (20)76 (20)76 (20)76 (20)682DG2/16S4-01Deceleration,two & four way,roller/cam operated05 210 (3000) 76 (20) 672DG1/17S4-01Two & four way,knob or leveroperated05 210 (3000) 76 (20) 672DG1/17S4-01Four way,knob orlever operated05 210 (3000) 76 (20) 672DG17S-8-10Four–way,manuallever operated08 210 (3000) 170 (45) 681DG3*-H8DG17*-H8DG5*-H8Pilot operatedLever operatedSolenoid controlled,pilot operated080808350 (5000)350 (5000)350 (5000)185 (700)185 (700)185 (700)GB-2327ADG3S-8Four-way,hydraulic piloted08 210 (3000) 380 (100) 670DG3S-H8Four-way,hydraulic piloted08 210 (3000) 530 (140) 670DG19S-8Four-way,air operated08 210 (3000) 379 (100) I-517906DG17S4-10Four-way,lever operated10 210 (3000) 340 (90) 681DG3S4-10Four-way,hydraulic piloted10 210 (3000) 946 (250) 67026


Stacking Valves: SystemStak modular valvesSystemStak valves make compact hydraulic systems in which modular valves are “sandwich”mounted between a directional control valve and a standard mounting surface. All circuit flowpaths are contained within the control valve and modules. With their cartridge design they providea compact hydraulic circuit at a reduced cost with the elimination of interconnecting piping.They are divided in<strong>to</strong> two groups- Valves acting in the pressure and/or tank lines (P and/or T)- Valves acting in the service lines (A and/or B)Each valve “stack” can be configured <strong>to</strong> provide the specific combination of functions required <strong>to</strong>meet system needs.Mounting surfaces and port patterns are <strong>to</strong> the international standard:02 size - ISO/DIS 4401–02–0203 size - ISO 4401-0305 size - ISO 4401-0506 size - ISO 4401-0607 size - ISO 4401-07Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogDGMC-2-1*DGMC-2-PTRelief 02 250 (3600) 30 (8) 5018/EN/0596/ADGMR(1)-2-1*DGMR-2DGMX2-2-1*Pressure control 02 250 (3600) 30 (8) 5018/EN/0596/ADGMDC-2 Direct check 02 250 (3600) 30 (8) 5018/EN/0596/ADGMPC-2Pilot operatedcheck02 250 (3600) 30 (8) 5018/EN/0596/ADGMFG-2 Flow control 02 250 (3600) 30 (8) 5018/EN/0596/ADGMFN-2 Flow restric<strong>to</strong>r 02 250 (3600) 30 (8) 5018/EN/0596/ADGMFD-2 Flow divider 02 250 (3600) 30 (8) 5018/EN/0596/A27


SystemStak modular valves (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogDGMC-03DGMC-05DGC5-H-06DGC-H-06Relief 03050606310 (4500)310 (4500)210 (3000)210 (3000)60 (16)120 (32)340 (90)340 (90)I-517380DGMR1-03DGMR1-05DGR-06Sequence 030506310 (4500)310 (4500)210 (3000)60 (16)120 (32)227 (60)I-517380DGMR-03DGMR-05Counterbalance 0305310 (4500)310 (4500)60 (16)120 (32)I-517380DGMX2-03DGMX2-05DGX-*06-* BDGX-*06-* FDGX-*06-* HReducing/Relieving0305060606310 (4500)310 (4500)210 (3000)210 (3000)210 (3000)60 (16)120 (32)57 (15)114 (30)265 (70)I-517380DGMDC-03DGMDC-05Direct check 0305310 (4500)310 (4500)60 (16)120 (32)I-517380DGMPC-03DGMPC-05DGPC-06Pilot operatedcheck030506310 (4500)310 (4500)210 (3000)60 (16)120 (32)227 (60)I-517380DGMFN-03DGMFN-05DGFN-06Flowrestric<strong>to</strong>r030506310 (4500)310 (4500)210 (3000)60 (16)120 (32)227 (60)I-517380DGM**-7Pressurecontrol07 315 (4500) 200 (53) GB-248028


Proportional controls: Directional and throttle controls, pilot operated, withintegral electronicsThese four-way solenoid operated proportional valves have a high dynamic performance whichenables them <strong>to</strong> be used in closed-loop applications, previously possible only with servo valves.Various spool options are available for rated flows up <strong>to</strong> 720 L/min (190 USgpm). Workingpressures are <strong>to</strong> 315 bar (4500 psi). In some models, the spool position is moni<strong>to</strong>red by an LVDTwhich feeds back information <strong>to</strong> the amplifier, enabling spool position <strong>to</strong> be accurately maintained.bAPBTModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)TypicalHyst. %CatalogKADG4V-3KADG4V-5Directionalcontrol withoutfeedback030520 (5.3)50 (13.2)350 (5000)310 (4500)


Proportional controls: Directional and throttle controls, pilot operated, withintegral electronics (continued)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)TypicalHyst. %CatalogK(B)F*G4V-3KF*G4V-3Directional controlwith feedback,with/ withoutintegral amplifier03 350 (5000) 28 (7.4)


Proportional controls: Directional controls, without/with electrical feedbackModel Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)TypicalHyst. %CatalogKDG3V-3KDG3V-5Proportionaldirectional,single-stage0305350 (5000)315 (4500)34 (9)95 (25)660KDG3V-5KDG3V-7KDG3V-8Proportionaldirectional,single-stage050708315 (4500)350 (5000)350 (5000)85 (22)180 (48)280 (74)GB-2405K(A)DG5V-5K(A)DG5V-7K(A)DG5V-8K(A)DG5V-10Proportionaldirectional,two-stage050708350 (5000) 90 (24)180 (48)280 (74)550 (145)45052/EN/0696/AGB-C-2325BKFDG5V-5KFDG5V-7KFDG5V-8Proportionaldirectional, withmainstagefeedbacktransducers050708350 (5000) 3 (0.8)


Proportional controls: Auxiliary function modules for proportional valvesModel Description MountingFaceMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogKDGMH-3KDGMH-5KDGMH-7KDGMH-8Single stage,hydrostat moduleSingle stage,hydrostat moduleSingle stage,hydrostat moduleSingle stage,hydrostat module03 315 (4567) 25 (6.6) GB-245905 315 (4567) 70 (18.5) GB-245907 250 (3600) 180 (47.5) GB-245908 250 (3600) 360 (95.0) GB-2459KDGMA-3Single stage,parallel flow pathmodule03 No functional limitations:dependent on valves usedGB-2459KDGMA-5Single stage,parallel flow pathmodule05 GB-2459DGMA-7Single stage,pilot shuttlemodule07 Must be placed betweenK*DG5V-7 directionalvalves andKDGMH-7-616268hydrostat modulesGB-2459DGMA-8Single stage,pilot shuttlemodule08 Must be placed betweenK*DG5V-8 directionalvalves andKDGMH-8-616269hydrostat modulesGB-2459 If both of these are <strong>to</strong> be used <strong>to</strong>gether.Proportional controls: Electrohydraulic proportional flow control valve(Valvis<strong>to</strong>r)Model Description Nom.SizeMaximumPressurebar (psi)MaximumFlow L/min(USgpm)CatalogEPV10Screw-in cartridgedesign providespressurecompensated flowcontrol without theneed for a separatehydrostat.10 210 (3000) 30 (8) 715EPV16 16 280 (4000) 160 (42) 55832


Servovalves<strong>Vickers</strong> servovalves are two–stage, four–way, flapper nozzle valves that providesystem closed loop control with exact positional accuracy, repeatable velocityprofiles and predictable force or <strong>to</strong>rque regulations.These servovalves offer a wide range of rated flows from 38 <strong>to</strong> 151 l/min(10 <strong>to</strong> 40 USgpm) at p of 70 bar (1000psi).Model Description Nom.SizeMaximumPressurebar (psi)Maximum FlowL/min (USgpm)CatalogABSM4–10Two-stage,four-way,flapper nozzle10 210 (3000) 38 (10) 651PRSM4–12Two-stage,four-way,flapper nozzle12 210 (3000) 45 (12) 651SM4–15Two-stage,four-way,flapper nozzle15 210 (3000) 57 (15) 651SM4–20Two-stage,four-way,flapper nozzle20 210 (3000) 76 (20) 652SM4–20–50Two-stage,four-way,flapper nozzle20 350 (5000) 76 (20) 662SM4–30–20Two-stage,four-way,flapper nozzle30 140 (2000) 113 (30) 653SM4–40–20Two-stage,four-way,flapper nozzle40 350 (5000) 151 (40) 654SX4–10Two-stage,four-way,flapper nozzle10 350 (5000) 38 (10) 650SX4–12Two-stage,four-way,flapper nozzle12 350 (5000) 45 (12) 650SX4–15Two-stage,four-way,flapper nozzle15 350 (5000) 57 (15) 650SX4–20Two-stage,four-way,flapper nozzle20 350 (5000) 76 (20) 65033


Electronics: Amplifiers & electrical accessories for proportional valvesThe <strong>Vickers</strong> power amplifiers are equipped with a 4-input (demand signal) moduleand 4-ramp function genera<strong>to</strong>r with quadrant detection. The ramp genera<strong>to</strong>r allowsacceleration and deceleration <strong>to</strong> be set separately for both directions of movement.A strip guidance controller serves <strong>to</strong> control the position of an electro- hydraulicactua<strong>to</strong>r, using optical sensors.The controller can be used for strip-edge orstrip-center guidance or stack height control. It consists of a power amplifier forproportional valves, and an integrated module for strip guidance control.The ‘‘soft switch’’ power plugs, conforming <strong>to</strong> ISO 4400/ DIN 43650 interface, offerlow cost solutions for solenoid-operated, non-feedback hydraulic proportional valvesthrough the use of an integral amplifier.Model Description For use with CatalogEEA-PAM-513-AEEA-PAM-523/525-AEEA-PAM-533/535-AEEA-PAM-553-AEEA-PAM-561-AEEA-PAM-568-AEEA-PAM-58-A“A” SeriesBasic power amp.KCG-3-10K*G4V-3/5KF*G4V-3/5KSDG4V-3KFDG5V-5/7KFDG5V-8KHDG5V-5/7/8GB-2137CGB-2464GB-2101AEEA-PAM-520-AEEA-PAM-525-A“A” SeriesBasic power amp. alsofor use with the Valvis<strong>to</strong>rproportional valveKD/TG4V-3...H7-2*KD/TG4V-5...H*-3*GB-2270AEEA-PAM-523-BEEA-PAM-525-BEEA-PAM-533-BEEA-PAM-535-BEEA-PAM-561-BEEA-PAM-568-BEEA-PAM-581-B“B” Serieswith command logicmodule and 2 rampsK*G4V–3.....H7-2*KF*G4V-5...H*-3*KF*G4V-3KF*G4V-5KFDG5V-5/7KFDG5V-KHDG5V-5/7/8GB-2472EEA-PAM-523-CEEA-PAM-525-CEEA-PAM-533-CEEA-PAM-535-CEEA-PAM-561-CEEA-PAM-568-CEEA-PAM-581-C“C” Serieswith command logicmodule and 4 rampsK*G4V-3.....H7-2*KF*G4V-5...H*-3*KF*G4V-3KF*G4V-5KFDG5V-5/7KFDG5V-KHDG5V-5/7/8GB-2473EEA-PAM-523-DEEA-PAM-525-DEEA-PAM-533-DEEA-PAM-535-DEEA-PAM-561-DEEA-PAM-568-DEEA-PAM-581-D“D” Serieswith PID modulesK*G4V-3.....H7-2*KF*G4V-5...H*-3*KF*G4V-3KF*G4V-5KFDG5V-5/7KFDG5V-KHDG5V-5/7/8GB-2474AEEA-PAM-523-EEEA-PAM-525-EEEA-PAM-533-EEEA-PAM-535-EEEA-PAM-561-EEEA-PAM-568-EEEA-PAM-581-E“E” Serieswith strip-guidancecontrollermoduleK*G4V-3.....H7-2*KF*G4V-5...H*-3*KF*G4V-3KF*G4V-5KFDG5V-5/7KFDG5V-KHDG5V-5/7/8GB-2475EEA-PAM-523-FEEA-PAM-525-FEEA-PAM-533-FEEA-PAM-535-FEEA-PAM-561-FEEA-PAM-568-FEEA-PAM-581-F“F” Serieswith strip-guidancecontrollermoduleK*G4V-3.....H7-2*KF*G4V-5...H*-3*KF*G4V-3KF*G4V-5KFDG5V-5/7KFDG5V-KHDG5V-5/7/8GB-2476AEHH-AMP-702-C/F-10EHH-AMP-702-D/E-10“Soft switch”power plugsKD/TG4V-3/5-HKD/TG4V-3/5-HGB-2114CGB-2115E34


Electronics: Amplifiers & electrical accessories for proportional valves(continued)Model Description For use with CatalogEHH-AMP-712-D/G-2*“Soft switch”power plugsKDG4V-3S-GP7-6*KTG4V-3S-GP7-6*KCG-3/6/8-GP1-1*KX(C)G-6/8-GP1-1*KDG5V-5/7/8-GP-1CMX-***-E-GEPV**-12D-1*ERV1/2**-12D-1*EPFR1**-12D-1*GB-2282CEHA-TEQ-700-2*Portable test equipmentfor KD, KT, KF, and KHseries proportionalvalves and associatedamplifiersElectronics: Single-cable connec<strong>to</strong>r (UNIPLUG)K*G4VKF SeriesKH SeriesGB-2462<strong>Vickers</strong> UNIPLUG system consists of a solenoid-operated valve fitted with a single-cableelectrical connec<strong>to</strong>r ideally suited for economical wiring of single- and double-solenoidmodels. It is suitable for use on <strong>Vickers</strong> ISO 03-size directional and proportional valves whichare fitted with the appropriate plug-in coils.Model For use with CatalogAA1 3 2+ A 0V24V4+ B1 2 3 4+ A + B 0V 24VBBEHH-AMP-724-A**-1*Plug with integral switching amplifiers for twosolenoids.EHH-AMP-724-C**-1*Plug with proportional amplifiers plus an adjustableramp <strong>to</strong> give ‘‘soft switching’’ of two solenoids from aswitching input signal.DG4V-3(S)KD/T4V-3(S)GB-2367CA1 2 3 4+ IN –IN 0V24VBEHH-AMP-724-D**-1*Plug with proportional amplifiers with independentgain and deadband for each of two solenoidoutputs, plus a common adjustable ramp.A1 3 2+ A 0V+ BBEHH-AMP-724-Z**-1*Plug for direct connection <strong>to</strong> solenoids of switchingvalves (no integral amplifier)35


Electronics: Amplifiers and electrical accessories for servo valves<strong>Vickers</strong> amplifiers, power supplies, and function modules provide a convenient andeconomical package of electronics for closed loop servo control.These electroniccomponents have been specially designed and assembled for high reliability andimproved ease of use. They can be applied in systems utilizing <strong>Vickers</strong> servovalves andproportional valves and may also be used <strong>to</strong> control competi<strong>to</strong>rs’ valves.EM series power supplies and the SMC 20H controller are panel mounted. EM seriesamplifiers and function modules plug in<strong>to</strong> fully compatible slots in the EMRS-A-11 andEMP-A-20 power supply units. The EEA series amplifiers are designed for use in astandard rack mount.Model Description CatalogEEA-PAM-591EM-D-30EM-J-10EM-K-10EMP-A-20EMRS-A-11Universal servovalve amplifier card designed<strong>to</strong> drive <strong>Vickers</strong> SM4, SX4, and SP4servovalves as well as other industrystandard servovalves, in open and closedloop systems.With PID. For driving single-polarity andbipolar servo valves, and other currentcontrolled valves.Programmer module. When used withEM-D-30 servo amplifier, provides a meansof presetting and selecting a variety ofpositions, speeds, or forces in closed loopsystems.Ramp module. For converting step changesin input signals <strong>to</strong> ramped signals, for smoothtransition from one operating level <strong>to</strong> another.When used with EM-D-30 amplifier, providesa means of controlling speed in positioningsystems, acceleration and deceleration inspeed control systems, and the rate ofpressure change in pressure controlsystems.Power supply unit designed for use with<strong>Vickers</strong> electronic control modules in singleand multiple axis electrohydraulic controlsystems. Provides the means for mounting up<strong>to</strong> four modules (two EM-D-30 amplifiers, oneEM-K-10 ramp module, and one EM-J-10programmer module. Supplies each with theproper excitation voltages, and connects it <strong>to</strong>external circuit components through a terminalstrip.Power supply unit designed for use with<strong>Vickers</strong> electronic control modules in singleaxis electro-hydraulic control systems.Provides the means for mounting onemodule, supplying it with the properexcitation voltages, and connecting it <strong>to</strong>external circuit components through aterminal strip.65665665665665665636


Electronics: Amplifiers for pressure and flow controlsA range of three “Snap-on” control modules for mounting in<strong>to</strong> control cabinets, usingrails <strong>to</strong> DIN EN 50022 or DIN EN 50035. The range is ideally suited for use with<strong>Vickers</strong> “KA” series of proportional valves with integrated drive electronics, whereexternal ramp generation, conversion from current <strong>to</strong> voltage command signals, etc.may be required.Model For use with/description CatalogEBA-TEQ-706-A-10 EEA-PAM-5** amplifier GB-2315EEA-AMP-451-A-1* In OP AMP circuitry GB-2095EEA-DSG-450-A-10To generate input signals for openand closed loop systems; drivingexternal command potentionmetersGB-2094EEA-LIM-454-A-10 Compara<strong>to</strong>r card GB-2098EEA-REL-452-A-10 Relay card GB-2096AEHA-CON-201-A-20EHA-PAM-291-A-20EHA-PID-201-A-20EHA-PSU-201-A-20EHA-PSU-704-A/B-1*EHA-PSU-704-A**-2*EHA-RMP-201-A-20EHD-AMP-73*-***-1*EHD-BUSEHD-DSG-201-A-10EHH-AMP-702-A-2*EMCS-*-30Electronic control modules forDIN-Rail-MountingFor controlling SM4 sectional valvesor other servo valves up <strong>to</strong> 200 mA.max. currentElectronic control modules forDIN-Rail-MountingElectronic control modules forDIN-Rail-MountingPower supply units24V DC x 3,5A max. outputPower supply units 24V DC x 10Amax. outputElectronic control modules forDIN-Rail-MountingDriving non-feedback proportionalvalvesPROFIBUS, Sinec L2-DP,Interbus-SCabinet mounting on rails for usewith KA, KV and UNIPLUG seriesSwitching power plug for use withsolenoid operated valves rated up<strong>to</strong> 24V DCRemote electricallymodulated (CGE) and(FGE) controlsGB-2410AGB-2093AGB-2427GB-2410AGB-2461GB-2419GB-2410AGB-2448AGB-2366GB-2470GB-2122DI–52155737


Cylinders<strong>Vickers</strong> line of hydraulic cylinders offers a wide variety of cylinder bore and rod diametersfor use in agricultural applications and construction equipment, as well as industrialmachines and vehicles.For example, the <strong>Vickers</strong> LESA Series TT servo actua<strong>to</strong>r, designed primarily for woodproducts processing applications, combines a high performance hydraulic cylinder and acontrol valve mounting manifold in one convenient package.Series& TypeNominalPressurebar (psi)CylinderBoremm (inch)Pis<strong>to</strong>n RodDiametermm (inch)CatalogTAAir17,25 (250) 19-200(0.75-8)9,5-57,2(0.375-2.25)4111ATEAir17,25 (250) 38,1-356(1.5-14)15,9-140(0.625-5.5)4110BTLNon-Lube, Air17,25 (250) 38,1-356(1.5-14)15,9-140(0.625-5.5)4110BTPNon-Lube, Air17,25 (250) 38,1-203(1.5-8)15,9-34,9(0.625-1.375)4093CTJAir7 (100) 38,1-203(1.5-8)12,7-34,9(0.5-1 3 / 8 )4112ATZHydraulicANSI/NFPA210 (3000) 38-200(1.5-8)15,9-140(0.625-5.5)5039.00/EN/1197/ATG/TM/TWHydraulic210 (3000) 38,1-508(1.5-20)15,9-254(0.625-10)4109BTVHydraulic(ISO Metric)160 (2320) 25-200(0.98-7.9)12-140(0.47-5.5)4147TF Hydraulic 70 (1000) 38,1-356(1.5-14)TB Hydraulic 70 (1000) 19-200(0.75-8)15,9-140(0.625-5.5)9,5-57,2(0.375-2.25)4110B4111ALESA 1Electrohydraulic210 (3000) 50,8-127(2.0-5.0)34,9-63,5(1.375-2.5)4108BLESA 2Electrohydraulic210 (3000) 50,8-127(2.0-5.0)34,9-63,5(1.375-2.5)4144LESASeries TT210 (3000) 50,8-127(2.0-5.0)34,9-88,9(1.375-3.5)5094.00/EN/0797/A38


Filters<strong>Vickers</strong> filters handle flows <strong>to</strong> 568 L/min (150 USgpm) and pressures <strong>to</strong> 415 bar (6000psi). A wide range of port sizes, bypass valves, pressure drop indica<strong>to</strong>rs and mediagrades facilitates filter installation and achievement of desired system cleanliness levels.Inch (H) or metric (M) ports are available.Reservoir vent filters BR110 and BR210 feature a visual indica<strong>to</strong>r andcorrosion–resistant housing. In addition <strong>to</strong> particle control, the BR110 also featureswater/moisture control.Series Description OperatingPressurebar (psi)MaximumFlowL/min(USgpm)CatalogH041M041Return line filter orlube oil with C-, E-, orL-Pak element28 (400) 1135 (300) H042M042H061M061HL15ML15HL16ML16HT15MT15Duplex filter withC-, E-, or L-PakelementReturn line filter (HF3),with C-, E-, or H-PakelementIn tank filter (HF4),with C-Pak elementIn tank filter (HF4),with C- and E-PakelementIn tank filter (HF4),with C-Pak element28 (400) 1135 (300) 41 (600) 189 (50) 14 (200) 379 (100) 14 (200) 568 (150) 7 (100) 76 (20) OFR-15/30 Return line filter (HF3) 41 (600) 114 (30) 5057/EN/0597/AOFR-60/120 Return line filter (HF4) 27 (400) 454 (120) 5057/EN/0597/AOFRS-15OFRS-25OFRS-60Return linespin-on filterReturn linespin-on filterReturn linespin-on filter7 (100) 57 (15) 5057/EN/0597/A7 (100) 95 (25) 5057/EN/0597/A7 (100) 227 (60) 5057/EN/0597/A Refer <strong>to</strong> Catalog 5057.00/EN/0597/A (inches) for more information on filters. Refer <strong>to</strong> catalog 5057.01/EN/0497/A (metric) for more information on filters.39


Filters (continued)Series Description OperatingPressurebar (psi)MaximumFlowL/min(USgpm)CatalogH021 & H023M021 & M023Return line spin-oncartridge with R- andW- Pak element14 (200) 227 (60) H022M022Return line spin-oncartridge with R- andW- Pak element14 (200) 454 (60) OF3–1010F50F100FH330M330H340M340H350M350H360M360H440M440H451M451S610H610M610S620H620M620Inlet strainerspin-on cartridgeIndicatinginlet strainersIndicatinginlet strainersIndicatinginlet strainersPressure filter withC- or H-Pak elementPressure filter withC- or H-Pak elementPressure filter (HF3)with C-, E-, or H-PakelementServo-Pro filter withC- or H-Pak elementPressure filter (HF2)with C- or H-PakelementPressure filter (HF4)with C-, E-, or H-PakelementPressure filter withC- or H-PakconstructionPressure filter (HF3)with C-, E- or H-Pakelement7 (100) 379 (100) 5057/EN/0597/A20 (300) 61 (16) 5057/EN/0597/A20 (300) 329 (87) 5057/EN/0597/A20 (300) 700 (185) 5057/EN/0597/A210 (3000) 23 (6) 210 (3000) 91 (24) 210 (3000) 189 (50) 210 (3000) 114 (30) 280 (4000) 24 (91) 310 (4500) 568 (150) 414 (6000) 208 (55) 414 (6000) 568 (150) Refer <strong>to</strong> Catalog 5057.00/EN/0597/A (inches) for more information on filters. Refer <strong>to</strong> catalog 5057.01/EN/0497/A (metric) for more information on filters.40


Power Packages: Off-Line Filtration System<strong>Vickers</strong> Off-Line Filtration units (OLF) provide 24 hour filtration, flushing and transferof oil for existing in-plant machinery. Each unit can be matched <strong>to</strong> individual systems<strong>to</strong> provide on-site filtration for any application.There are six ‘‘families’’ of OLF’s, based on the pump size in each unit. Pump flowsrange from 74 L/min (19.5 USgpm) <strong>to</strong> 568 L/min (150 USgpm). A number of differentpump/mo<strong>to</strong>r and filter combinations comprise each ‘‘family.’’TypeDescription(Catalog)APBTAPBTAPBTOff-Line Filtration Pumps . . . . . . . . . . . . 74-568 L/min (19.5-150 USgpm)Electric mo<strong>to</strong>rs . . . . . 1800 rpm(5063.00/EN/0497/A)MPower Packages: Global SystemPak and SystemCenter<strong>Vickers</strong> Global SystemPak vertical mo<strong>to</strong>r pump power units and SystemCenterpower units offer capacities, control options and configurations <strong>to</strong> fit virtually anyapplication requirements. The global design offers a wide variety of manifold optionsand a choice of pumps <strong>to</strong> match application requirements while ensuring cost-effectiveoperation and optimum productivity.TypeDescription(Catalog)Global SystemPak Tanks . . . . . . . . . . . . . 8-95 liters (2-25 US gallons)Pumps . . . . . . . . . . . . 1,9-36 L/min (0.5-9.5 USgpm)Electric mo<strong>to</strong>rs . . . . . 0.25-5hp;1800 & 3600 rpmMax. pressure . . . . . . 210 bar (3000 psi)(5042/EN/1196/A)SystemCenter Tanks . . . . . . . . . . . . . 38-303 liters (10-80 US gallons)Pumps . . . . . . . . . . . . 3,8-155 L/min (1-41 USgpm)Electric mo<strong>to</strong>rs . . . . . 1-50 hpMax. pressure . . . . . . 210 bar (3000 psi)(464)41


Power Packages: Integrated Mo<strong>to</strong>r PumpThe <strong>Vickers</strong> Integrated Mo<strong>to</strong>r Pump is a unique combination of a conventional ACinduction mo<strong>to</strong>r cooled with system hydraulic oil and <strong>Vickers</strong> hydraulic pump, either fixedvane pump or variable pis<strong>to</strong>n type, housed in a special sound reduction enclosure. Thiscombination provides an exceptionally quite and small pumping package for anyindustrial application requiring up <strong>to</strong> 125 horsepower (92 kilowatts) of continuoushydraulic power.Description(Catalog)OutputMo<strong>to</strong>r PowerkW (hp)Combination AC induction mo<strong>to</strong>r, cooled with system hydraulic oil,and <strong>Vickers</strong> hydraulic pumps, either single or double fixed vane orvariable pis<strong>to</strong>n pumps. Series MP15-MP92.(5035.00/EN/1196/A)15 (20)22 (30)45 (60)75 (100)92 (125)42


AccessoriesModel Description CatalogABT-03/ABS-12Air bleed valve w/NPT threads orSAE straight threads690A1-**-11 & 30Accumula<strong>to</strong>rs, bladder type,10 cu. in. <strong>to</strong> 10 gallons690DSB-1-03-10 Ball shuttle valves, with SAE straight threads 690DSB-1-03-10Angle and globe valves,plug or needle type with NPT threads690DTNASDTNS3Needle valves, angle or tee,shu<strong>to</strong>ff w/ 1/4” NPT threads690FB-A/B/C-10Foot bracket kits formounting hydraulic mo<strong>to</strong>rs or pumps690FL1-*-***-10 Flanges, SAE 4-bolt solid 690GM/GP-*-*-*-30Pressure gauges bourden tube type,0 - 5000 psi690GM/GP-120-2-10 Pressure gauges diaphragm type, 0-120 <strong>to</strong> psi 690GS-1000/2000/3000Pressure gauges spring loaded,0-3000 psi690OCA-**–30 OCW-**-30 Oil coolers, air and water type 690SPDT typeVacuum and pressure switches,5 in. Hg <strong>to</strong> 75 psi69043


Index of referenced catalogs and available languagesEnglish Deutsch Francais Italiano Espanol464 – – – –539 – – – –558 DC 2368A F 2368A I 558 E 2368A560 D 2343 – – –591 – – – –614 D 2168 – – –615 – – – –627 D 627 F 627 I 627 E 627645 – – – –650 – – – –651 – – – –652 – – – –653 – – – –654 – – – –656 – – – –658 – – – –660 – – – –669 – – – –670 – – – –671 – – – –672 – – – –674 – – – –679 – – – –681 – – – –682 – – FV 623 –685 D 501B FV501 – –686 – – – –689 – – – –690 – – – –691 – – – –695 – – – –698 – – – –708 D 708 F 708 I 708 E 708715 D 715 F 715 I 715 –720 – – –721 D 721 F 721 I 721 –722 D 722 F 722 I 722 –723 D 723 F 723 I 723 –724 D 724 F 724 I 724 E 724725 D 725 – I 725 –726 D 726 – I 726 E 726727 D 727 – I 727 –728 D 728 – I 728 –737 D 737 F 737 I 737 –4093C – – – –4108B – – – –4109B – – – –4110B – – – –4111A – – – –4112A – – – –4144 – – – –4147 – – – –5007.01/EN/0896/A 5007.01/D/0896/A – 5007.01/I/0896/A 5007.01/E/0896/A5007.02/EN/0196/A – – – –5008.00/EN/0596/A 5008.00/D/0586/A – 5008.00/I/0596/A 5008.00/E/0596/A5014.00/EN/0297/A – – – –44


Index of referenced catalogs and available languages (continued)English Deutsch Francais Italiano Espanol5016/EN/1196/A – – – –5018/EN/0596/A 5018/D/1296/A 5018/F/1296/A 5018/I/1296/A 5018/E/1296/A5035.00/EN/1196/A – – – –5039.00/EN/1197/A – – – –5042/EN/1196/A – – – –5043.00/EN/0496/A 5043.00/D/0496/A – – –5050.00/EN/0596/A – – – –5052/EN/0696/A – – – –5057/EN/0597/A 5057.01/D/0597/A 5057.01/F/0597/A 5057.01/I/0597/A 5057.01/E/0597/A5059.00/EN/1097/A – – – –5069.00/EN/0497/A 5069.00/D/0497/A F 2281A – –5071.00/EN/0497/A – – – –5071.01/EN/0497/A – – – –5071.02/EN/0497/A – – – –5071.03/EN/0497/A – – – –5082.00/EN/0397/A – – – –5094.00/EN/0797/A – – – –5110.00/EN/1297/A – – – –GB 404A D 404A FV 404 – –GB 642A D 642A FV 642A – –GB 2047A – – – –GB 2047B D 2047A – – –GB 2093A D 2093A F 2093A I 2093A E 2093AGB 2094A D 2094A – – –GB 2095A D 2095A – – –GB 2096A D 2096A – – –GB 2098A D 2098A – – –GB 2101A – – – –GB 2114C D 2114C F 2114C I 2114C –GB 2115E D 2115E F 2115E I 2115E E 2115EGB 2137C – – – –GB 2122D D 2122D D 2122D – –GB 2270A D 2270A F 2270A – –GB 2278A D 2278A F 2278A – –GB 2282C D 2282C F 2282C I 2282C –GB 2315 D 2315 – – –GB 2322D – – – –GB 2323A D 2323A F 2323A I 2323A E 2323AGB 2326A– – –DV 639GB 2326B– – –GB 2327A – – – –GB 2329A D 2329A F 2329A – –GB 2339A D 2339A F 2339A – –GB 2367C D 2367C F 2367C I 2367C E 2367CGB 2379B – – – –GB 2342 – – – –GB 2366 – – – –GB 2405 – – – –GB 2410A D 2410B F 2410B – –GB 2419 D 2419 – I 2419 –GB 2427 – – – –GB 2448A – – – –GB 2452 – – – –GB 2457 – – – –GB 2459 – – – –GB 2461 D 2462 – – –45


Index of referenced catalogs and available languages (continued)English Deutsch Francais Italiano EspanolGB 2462 D 2462 – – –GB 2464 D 2464 F 2464 – –GB 2470 – – – –GB 2472 D 2472 F 2472 I 2472 –GB 2473 D 2473 F 2473 I 2473 –GB 2474A D 2474A F 2474A I 2474A –GB 2475 D 2475 F 2475 I 2475 E 2475GB 2476A D 2476A F 2476A – E 2476AGB 2480DV 435DV 517DV 719–––DV 436 F 2408 – –GB-C-2010 – – – –GB-C-2037 – – – –GB-C-2129 – – – –GB-C-2132 – – – –GB-C-2123C – – – –GB-C-2162E – – – –GB-C-2321A D 2321A FV 2321A – –GB-C-2324D – – – –GB-C-2325A – – – –GB-C-2325B – – – –GB-C-2330A PV 407 FV 407 – –GB-V-117 – – – –I-135010 – – – –I-135011 – – – –I-513700 – – – –I-517380 – – – –I-517906 – – – –I-521557 – – – –––––––46


Notes47


Ea<strong>to</strong>n Hydraulics15151 Highway 5Eden Prairie, MN 55344Telephone: 612 937-7254Fax: 612 937-7130www.ea<strong>to</strong>nhydraulics.com46 New Lane, HavantHampshire PO9 2NBEnglandTelephone: (44) 170-548-6451Fax: (44) 170-548-7110Form No. 00-000 Copyright Ea<strong>to</strong>n Corporation, 0000All rights reserved.Printed in U.S.A511400/EN/0198/APrinted in USA