<st<strong>ro</strong>ng>Fan</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>Coil</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>Unit</st<strong>ro</strong>ng><st<strong>ro</strong>ng>CITIZEN</st<strong>ro</strong>ng> - <st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng> <st<strong>ro</strong>ng>Serie</st<strong>ro</strong>ng>Installation Guide Book
IndexDimensions and weight………………………………………………………….1Physical data……………………………………………………………………..2Electrical data……………………………………………………………………2Operating limits………………………………………………………………….3Warning avoid……………………………………………………………………3Installation………………………………………………………………………..6Water connection…………………………………………………………………7Electrical connections……………………………………………………………8Cont<strong>ro</strong>l……………………………………………………………………………8Wiring diagram…………………………………………………………………...9Maintenance……………………………………………………………………..10
Installation InstructionAir dischargeGrillCont<strong>ro</strong>l box panelFeetAir intakeDimensions and weightModelADimension(mm)B<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>150 700 400<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>200 900 600<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>300 1100 800<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>400 1100 800<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>600 1350 1000<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>800 1500 1200<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>1000 1700 1400<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>1200 1700 14001
Installation InstructionPhysical dataModelCapacity(Kw) Airflow(m3/h) <st<strong>ro</strong>ng>Coil</st<strong>ro</strong>ng>Cooling Heating High speed Water flow(l/s) Pressure d<strong>ro</strong>p(Kpa)<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>150 1.16 2.10 223 0.06 6<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>200 1.92 3.26 340 0.09 8<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>300 2.79 4.65 510 0.13 17<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>400 3.84 6.40 680 0.18 18<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>600 5.31 8.68 1100 0.25 27<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>800 7.68 2.79 1360 0.36 36<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>1000 8.72 4.53 1700 0.42 45<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>1200 10.47 17.45 2040 0.50 22Condition:Cooling mode: entering air temperature 27°C db/19°C wb, entering/leaving water temperature 7/12°C, high fan speed.Heating mode (2-pipe coil): entering air temperature 20°C, entering water temperature 50°C, high fan speed, water flow rate ascooling mode.Electrical dataModel<st<strong>ro</strong>ng>Fan</st<strong>ro</strong>ng>MotorType Qty Type Qty Power input(w) Current input(A)<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>150 1 1 27 0.11<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>200 1 1 31 0.15<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>300 1 1 35 0.16<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>400 Forward slope multi-wings 2 PSC(Permanent <st<strong>ro</strong>ng>Serie</st<strong>ro</strong>ng>s 1 50 0.22<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>600 centrifugal type3 Capacitor) 2 87 0.38<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>800 4 2 100 0.45<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>1000 4 2 160 0.75<st<strong>ro</strong>ng>FCU</st<strong>ro</strong>ng>1200Three-speed electric motors with permanent capacitor, class B42 174 0.88Operating limitsWater circuitIndoor temperaturePower supplyWater- side maximum pressure Minimum entering water temperature: + 4℃1400 kPa (142 m w.c.) Maximum entering water temperature: + 65℃Minimum temperature: 5℃Maximum temperature 32℃Nominal single phase voltage 230V ~ 50 HzOperating voltage limits min. 198V - max. 264V2
Installation InstructionWarning avoid…any obstruction of the unit air outlet or return.Leave 1 meter minimum of free space.…exposure to oil vapours.…installation in areas with high frequencywaves.…any rise in the condensate drain piping.…horizontal condensate drain piping with lessthan 2% slope.…slack on electrical connections.…disconnecting water connections afterinstallation.3
Installation Instruction…exposure to direct sunshine, when unit isoperating in cooling mode; always use shutte<strong>ro</strong>r shades…position too close to heating sources whichmay damage the unit.…connecting condensate piping to sewagesystem drain without app<strong>ro</strong>priate trap. Trapheight must be calculated according to the unitdischarge head in order to allow sufficient andcontinuous water evacuation.…only partial insulation of the piping.…installation not correctly leveled which willcause condensate dripping.…flattening or kinking pipes or condensate pipes.4
Installation InstructionInstallationScrew anchorsThe floor mounted unit must be p<strong>ro</strong>vided withsupposing feet.• Drill four holes for the screw anchors.• Position unit to wall and secure it with screws.• To facilitate cabinet installation, it is suggested touse flathead screws.• To complete the installation make electrical andwater connections as per the diagram inside thecont<strong>ro</strong>l box panel.5
Installation InstructionWater connectionWater outlet hole 3/4” femaleWater inlet hole 3/4” femaleCondensate water drain pipeWater piping can enter either f<strong>ro</strong>m the floor or f<strong>ro</strong>m the wall. Leave the space shown in the figureabove.The unit coil can be supplied with water connections positioned as requested.NOTE:The connection pipes must be insulated with a condensation-p<strong>ro</strong>of material such as polyurethane,p<strong>ro</strong>pylene or neoprene of 5 to 10 mm thickness.6
Installation InstructionElectrical connections1 2 3 4 5 6Wiring boxIMPORTANT:• Make earth connection prior to any other electrical connections.• Disconnect the power supply to all circuits prior to handling any electrical components.• Before p<strong>ro</strong>ceeding with the unit connection to the mains supply locate live L and neutral N,then make connections as shown in the wiring diagram.• Ensure that the mains supply connection is made th<strong>ro</strong>ugh a switch that disconnects all poles,with contact gap of a least 3 mm.• The fan coil connecting cable as well as accessory wires must be H07 RN-F type (or higher),synthetic rubber insulation with Neoprene coating, according to EN 60335-2-40 andHD277.S1 codes and located in a p<strong>ro</strong>per rigid conduit.• For the unit power supply, it is recommended to use cables with a minimum size of 1.5 mm 2 .Cont<strong>ro</strong>l box panel. The cont<strong>ro</strong>l box panel is always positioned opposite the waterconnections.• Two different cont<strong>ro</strong>l box panels are available: one for a unit without electric heater, and onefor a unit with electric heater. Inside each cont<strong>ro</strong>l box panel there is a terminal block for theelectrical connections (see wiring diagrams). After connections have been completed, cablesmust be secured with the cable holders supplied.• If the unit is fitted with an electric heater, this must have a separate power supply.Cont<strong>ro</strong>l3-speed analog switcherCDST-8017
Installation InstructionWiring diagramFM fan motorCap capacitanceSS three-speed on-offTB connecting terminal- - - - - - - - -going to be connected__________ connected• Turning the unit ON and OFF.• Changing the operation modes.• Temperature selection.• Leave the installation manual with the owner for future use during maintenance operations or forany other needs.MaintenanceAir filterCheck and make sure that the filter is cleaned at least once a month or more often if unit is locatedin a dusty <strong>ro</strong>om. A dirty filter reduces the air flow and unit efficiency.To inspect filter p<strong>ro</strong>ceed as follows:• switch the unit OFF;• loosen the two screws located at the base of the unit and the corresponding plates;• lower the two guides and withdraw filter;• clean the filter gently with soapy water or with a vacuum cleaner;• reinsert and position the filter in the guides, keeping the photo catalytic filter tabs upwards asillustrated;• return the filter guides to their original position;• tighten the screws and associated plates.It is advisable to clean and if necessary replace the air filter before the winter season.Condensate drainingDuring the summer season check that the condensate drain is free f<strong>ro</strong>m dust and lint that could8
Installation Instructionclog it, causing condensate water overflow.Heat exchanger coilAt the beginning of any winter and summer season it is advisable to check that the coil fins are notclogged with dust, lint or other foreign matter. Clean the heat exchanger after having removed thesupply grille, taking care not to damage the fins.MotorThe motor is permanently lubricated. Therefore no periodical maintenance is required.9