Elster Kent Non Metalic Meters - Incledon
Elster Kent Non Metalic Meters - Incledon
Elster Kent Non Metalic Meters - Incledon
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ELSTER KENT <strong>Non</strong>-<strong>Metalic</strong> Products<strong>Meters</strong>, Meterboxes & Accessories made fromEngineering Plastics
1Accuracyand long-lifestem fromengineeringexcellenceLockingDeviceReadingSlotThe <strong>Elster</strong> <strong>Kent</strong> range of non-metallic products are madefrom tough, high quality, UV resistant engineering plastics.The range of meterboxes house 15, 20 and 25mm meters.For 15 domestic installations, there is a choice of the low costRDP4 meterbox for 114mm long plastic meters. For plasticmeters 165mm long, there is the standard meterbox. Thesemeterboxes house a quality 3-way lockable plastic trickle flowballcock except the B1100 meterbox has a 2-way lockableplastic ball valve. Class C meters are fitted in all sizes ofmeterboxes and there is an approved pulse output on allV110T KSMT variants including the B1100 meterbox with 25mmmeter for upgrade to automatic meter reading (AMR).SlidingCouplingBase Plate3 Way TrickleFlow Valve20mm GlassNylonReinforcedFemale InletFurther features include a patented locking mechanism,requiring a special key to open the lid; unique couplingdesigned to slide back facilitating meter replacement; themeter/ballcock assembly is keyed where it passes throughthe meterbox to prevent it from rotating during installation;high quality shuttoff ball valves without rising headparts whichcan cause leaks. The B1100 standard meterbox has a 19mmexternal 2-way municipal ballcock fitted in a valve box.20mm GlassNylonReinforcedFemale InsertTheV110T KSMVolumetricWater MeterRange15mm (114) 15mm (165) 20mm (165) 25mm (198)
2TheV110T KSMVolumetricWaterMeterThe V110T KSM meter is designed for themeasurement of cold potable water andoffer accurate, long maintenance-freelife and is highly-resistant to tampering.The range includes three differentclass C meters to suit maximum flowrates from 3.0m 3 /h to 7.0m 3 /h. TheV110T KSM's are suitable for watertemperatures up to 50˚C and a maximumworking pressure of 1600 kPa. Standardcounter registration is m 3 and litres. Thismeter has a blended UV stabilisedpolyacetal engineeringplastic body.It is a semi-positive rotary piston type wetdial water meter. It has a sealed wet dialcounter and a 7mm thick lens completewith a non-return valve and pulseoutput facility.Compliance with standardsEvery V110T KSM water meter is individuallytested over its flow range before despatch.Performance figures for the KSM rangemeet the requirements of the following:• Approved by SABS 1529-1:1994.• ISO 4064-1.• Approval number SA842The meter has an approved pulse outputand is also approved for both vertical andhorizontal installations.CounterThe combined counter and gear unit isliquid filled and sealed, with a simplestraight-reading presentation. The numberrollers are totally immersed in a non-toxicliquid which acts as a lubricant. The sacattached to the counter casing acts as abalancing membrane and ensures thepressure of the liquid in the counter is thesame as that of the water inside the meter.The counter is placed in a window insidethe meter body for easy reading.Black numerals on white denote cubicmeters, white numerals on reddenote litres.Meter SpecificationsNominal Sizemm 15 (114) 15 (165) 20(165) 25(198)Maximum flow rate qs ±2% m 3 /h 3.0 3.0 5.0 7.0Permanent flow rate qp ±2% m 3 /h 1.5 1.5 2.5 3.5Transitional flow rate qt ±2% 1/h 22.5 120 37.5 52.5Minimum flow rate qmin ±5% 1/h 15.0 30.0 25.0 35.0Starting flow (approximate) 1/h 5.7 5.7 9.5 13.2Head loss at qmaxMeter resets to zero at m 3 10 000Refer to graph10 000 10 000 10 000Minimum indicated digit value m 3 0.00002 0.00002 0.00002 0.00002Pulse output (litres per pulse) litre 0.5 0.5 0.5 0.5Maximum working pressure kPa 1 600 1 600 1 600 1600Maximum water temperature ˚C 50 50 50 50Meter length mm 114 165 165 198Weight - meter only gram 433 477 498 662TamperproofThe V110T KSM offers outstandingresistance to illegal tampering. Its uniqueconical body-half design means it cannotbe dismantled while in service and themechanically-driven counter cannot beinterfered with magnetically. An individualserial number is engraved on each body.Features• Pulse output.• <strong>Non</strong>-return valve (internal disc-typereverse flow restrictor which reducesthe possibility of water being runback illegally).• Grooved piston(see diagram next page: V130T)Head loss curves (Typical) 15 & 20mm KSM T water metersHead loss (kPa)1001000 100002 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9114 KSM 15 mm ..............165 KSM 15 mm .................165 KSM 20 mm ...................198 KSM 25 mm ....................10090807060504030201098765412 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9100 1000Litres per Hour1000032Accuracy %Typical flow graph for volumetric meters109876543210-1-2-3-4-5-6-7-8-9-10MaterialsAll meters are manufactured from highestquality materials ensuring maximumresistance to wear and corrosion. Acomprehensive technical manualis available.1 10 100 1000Flow rate %
3TheV130TConcentricWaterMeterThe V130T concentric semi-positive rotarytype domestic meter is designed for themeasurement of cold potable water andoffers accuracy, long maintenance-freeworking life and is highly resistant totampering. The V130 has a standardinlet/outlet size of Ø 47.5mm and iscompatible with all meter manifolds thatcomply with BS5728 specifications.Revolutionary Grooved PistonPerformance SpecificationsNOMINAL SIZE qp1.5Meter Specificationsmm 15mm Class BActualPerformanceMaximum flow rate qs ±2% m 3 /h 3 5.Permanent flow rate qp ±2% m 3 /h 1.5 2.5Transitional flow rate qt ±2% 1/h 120 22.5Minimum flow rate qmin ±5% 1/h 30 15Starting flow 1/h 5 5Maximum working pressure kPa 1 600 1 600Meter Resets to Zero m 3 10 000 10 000Minimum Indicated Value m 3 0.00002 0.00002Pulse Output (Litres per pulse) l 0.5 0.5Maximum Water Temperature ˚C 50 50Weight (meter only) g 550 550Height mm 141 141Diameter mm 111 111The V130T Concentric Meter is currently approved to Class B (qp 1.5)Ø 111mm18,2mm141 mmPressure Drop GraphPressure Drop across V130T meter1000100 2 3 4 5 6 7 8 9Ø 111mmØ 47,5 G1 1/2" BSP2 3 4 5 6 7 8 9141 mm1000010090807060504030The <strong>Elster</strong> <strong>Kent</strong> V130T meter combines topin, bottom out chamber design with theunique grooved piston design in themeasuring chamber. This assists thepassage of suspended solids and givesexcellent flow characteristics.The result is dramatically reduced meterstoppages, improved durability and superiorperformance.Relative motion of the grooved piston. it'saction with the stationary chamber wall,creates small flow eddies which hold solidsin suspension until flushed out, reducingmeter stoppages.Features/Benefits• Wide accurate measuring range between 15 l/hand 5000 l/h• A meter with a low flow measuring accuracy better than aClass B 15mm meter and a maximum flow rate of a20mm meter in one.• Sealed wet dial counter• Prevents condensation under the lens.• Mechanical drive type counter• Prevents external magnetic interference.• Standard concentric inlet/outlet design• Easy installation in all makes of approved manifold meterboxes (BS5728)• Pulse output 2 pulses per litre)• Upgradable to EMR, AMR, pre-payment, loggable etc.• Volumetric measuring principle• Low flow meter accuracy not affected by angle of installation.• Revolutionary grooved piston• Improved durability and performance.HEADLOSS (Kpa)12 3 4 5 6 7 8 9 2 3 4 5 6 7 8 9100 1000 10000RATE OF FLOW (l/h)201098765432ACCURACY %Typical Flow Graph109876543210-1-2-3-4-5-6-7-8-9-1010 100 1000 10000FLOW RATE l/h
4TheEZ3AboveGroundMeterboxwith a 114mm longClass C V110TKSM meterEngineering thermal plastic EZ3 aboveground meter box housing, 15mmV110 KSMT plastic bodied water meter114mm long with non-return valve andfixed one pulse per 1 /2 litre outputfacility, of the semi-positive rotary pistontype and approved under the tradeMetrology Act and Regulations and toSABS 1529-1:1994 class C specifications,complete with unique high qualityplastic three-way (open/closed/trickleflow) ball valve fitted upstream of themeter and a similar two-way(open/closed) consumer ball valvecomplete with 25mm HDPE internalpiping and 3 /4'' (20mm) BSP glassnylon reinforced female connectors.Optional Extras:200 l/day ElectronicdispenserPre-payment meter(must be specified attime of order) Automaticmeter reading (AMR)Ground LevelFeatures:• Easy to find and read• Easy to install• No interest to thieves as all parts aremanufactured from engineering plastic• Robust• Upgradeable to automaticmeter reading• Meter has pulse output of 2 pulses perlitlre as a standardTheAbove GroundConcentricMeterboxwith a Class B15/20mm multirange meterThe <strong>Elster</strong> <strong>Kent</strong> Above Ground MeterBox is manufactured ofnon-metalic, UV resistant material,housing a plastic V130T Multi-Range(15/20mm) water meter with 25mmfusion welded pipes and fittings allwithin the box. The reading slot iscovered by a flip back cover.The plastic V130T Manifold Meter isapproved to Class B 15mmspecification and has a maximumflow rate of a 20mm meter and alsohas an approved pulse output of2 pulses per litre.The concept of raising the meterinstallation off the ground makes themeter easier to read plus gives theadvantage of freedom from flooding,and dirt and mud obscuring thecounter reading. By pre-plumbing andpressure testing the whole unit for leaksit is ready for installation. The municipal3 way trickle flow ball valve is actuatedfrom the outside using a 10mm Allenkey. The inlet and outlet connectionsare 20mm ( 3 /4'') glass nylon reinforcedfemale threaded for use with 20mmmale threaded pipe adaptors(not supplied)Features• Easy to find and read.• Easy to install.• No interest to thieves as all partsare manufactured fromengineering plastic.• Robust.• Multi range meter (15mm &20mm in one).• Upgradeable to automaticmeter reading.• Meter has pulse output of 2 pulsesper litre as a standard.• Low pressure drop.
5TheRDP4Meterboxwith a 114mm longClass CV110T KSM meterMeterbox Features:• Base Plate• 13mm 3 way trickle flow ballvalve (plastic)Meterbox Option• Lockshield for 3 way ball cockSpecifications:External connections:20mm female thread.Mass with Meter:2,2kgMeter Type:114mm long 15mm Class C volumetric plasticwet dial V110 KSMT meter with pulse outputand non-return valve.Stop Valve:13mm 3 way plastic flow ballvalve (plastic)TheStandardMeterboxwith a 165mm long20mm Class CV110T KSM meterMeterbox Features:• Base Plate• 13mm 3 way plastic trickleflow ball valve (plastic)Meterbox Option:Lockshield for 3 way ball valve (plastic)Specifications:External Connections:20mm glass nylon reinforced insert.Mass With Meter: 2,2kgMeter Type:165mm long 20mm Class C, wet dialvolumetric V110T KSM meter with pulse outputand non-return valve.Stop Valve:13mm 3 way plastic trickle flow ball valve.
6TheB1100StandardMeterboxwith a 198mm long25mm Class CV110T KSMwith anon return valveMeterbox Features:• Base Plate• 19mm external 2 waymunicipal ball valve (plastic) fittedin a valve box.Specifications:External Connections: 25mmPlastic male iron threadsMass With Meter: 2,8kgMeter Type: 198mm long 25mmclass C volumetric plastic wet dialV110T KSM with non-return valveand pulse output.Stop Valve: 19mm external 2 waymunicipal ball valve (plastic) fitted ina valve box.TheWallMountedMeterboxwith a 114mm longClass CV110T KSM meterThe wall mounted meterboxcomprises of a plastic Class CV110T KSM meter complete withnon-return valve and pulse outputfacility, pre-piped and pressuretested and is ready for easyinstallation. The unit comes with a3 way trickleflow ballcock and iseasily upgradeable to 200 litre aday dispensor or electronic meterreading (AMR).Connectors:20mm female brass BSPthreadedOptional Extra'sLockshield for trickleflow ballvalve (plastic)
7TheConsumerValveBoxConsumer Valve Boxwith a 13mm ball valve (plastic) and 20mm glassnylon reinforced female inlet and outlet.364mmTheStandardPlasticMeterboxwith 165mm long15mm or 20mmClass BV110T KSM meter64mmSpecifications:External Connections:20mm glass nylon reinfoced insert.Mass With Meter: 2,2kg178mmMeterbox Features:• Base Plate• 13mm 3 way plastic trickleflow ball cockMeterbox Option:Lockshield for 3 way ball cockMeter Type:165mm long 15mm Class B, Plastic wetdial volumetric V110T KSM meter withpulse output and non-return valve.Stop Valve:13mm 3 way plastic trickle flowball cock.WarrantyAll goods are tested and inspected prior to despatch. In the event of defects resulting from faulty workmanship or materials, such goodswill be replaced/repaired at our discretion, free of charge at the factory, but no responsibility will be accepted for any direct or consequentialdamage. This warranty covers the malfunction of a correctly installed item due to a manufacturing fault, but does not cover wear and tearconsidered normal at the locality of installation. Meter warranty 3 years from date of manufacture.JOHANNESBURGTel: (011) 470-4900Fax: (011) 474-0175DURBANTel: (031) 266-4915Fax: (031) 266-9521CAPE TOWNTel: (021) 511-8465/6Fax: (021) 511-8446BLOEMFONTEINTel: (051) 430-2603Fax: (051) 435-1455PORT ELIZABETHTel: (041) 363-1943/2026Fax: (041) 363-2127The company's policy is one of continuousimprovement and the right is reserved tomodify the specifications without notice40010/8/2008