TeeJet 854 Operating Manual_98-05051 R1

Installation, Programmingand Operating Manual98-05051


User GuideSW Ver. 1.16


854 Sprayer Control98-05051 2R1


Table Of Contents854 Sprayer ControlINTRODUCTION ........................................................................................................................................ 4PROGRAMMING GUIDELINES.............................................................................................................. 5IMPORTANT PRELIMINARY INFORMATION .................................................................................................. 5POWERING CONSOLE ON/OFF............................................................................................................. 6POWER ON.................................................................................................................................................. 6POWER OFF ................................................................................................................................................ 6OEM PROGRAM MODE – TEEJET 854 CONTROLLER.................................................................... 7NUMBER OF BOOM SECTION SWITCHES ON THE CONSOLE........................................................................ 7LANE WIDTH (GLM WORKING UNITS) ......................................................................................................... 8REGULATION PARAMETERS........................................................................................................................ 8Minimum Regulating valve Voltage..................................................................................................... 9Regulation Stop Band ......................................................................................................................... 10Rotation Time of Regulating Valve .................................................................................................... 11DISPLAY STABILIZATION.......................................................................................................................... 12DATA DISPLAY SCREEN OPTIONS............................................................................................................. 12CALIBRATE TIP LEVEL % ......................................................................................................................... 13DIGITAL OUTPUT #2................................................................................................................................. 14DUAL BOOM REGULATION MODE ............................................................................................................ 15FILL VALVE DEFAULT.............................................................................................................................. 16AUTO POWER DOWN TIME................................................................................................................... 16TEEJET COMMUNICATION SYSTEM (TCS) CONFIGURATION .................................................................... 17Job Operating System ......................................................................................................................... 17Console Identification #...................................................................................................................... 17MAXIMUM SPEED ACHIEVED ................................................................................................................... 18HIDDEN AREA COUNTER.......................................................................................................................... 18HIDDEN VOLUME COUNTER ..................................................................................................................... 18PRESSURE TRANSDUCER CALIBRATION (P HI).......................................................................................... 19MEMORY SAVE FUNCTION ....................................................................................................................... 21SYSTEM SETUP MODE – TEEJET 854 CONTROLLER ................................................................... 22SELECTION OF WORKING UNITS .............................................................................................................. 22RESET TO DEFAULTS................................................................................................................................23SPEED SENSOR CALIBRATION................................................................................................................... 23Proximity / Magnetic Pulses ............................................................................................................... 23Automatic Calibration:........................................................................................................................ 24DISTANCE COUNTER ................................................................................................................................25PRESSURE HOLD?..................................................................................................................................... 26PRESSURE SENSOR INSTALLED? ............................................................................................................... 26PRESSURE TRANSDUCER LOW PRESSURE CALIBRATION (P REF).............................................................. 27Automatic Calibration......................................................................................................................... 27PRESSURE TRANSDUCER MAXIMUM RATING (P HI) ................................................................................. 28FLOW METER SENSOR INSTALLED?.......................................................................................................... 28FLOW METER PULSES............................................................................................................................... 29Manual Entry ...................................................................................................................................... 29Automatic Calibration......................................................................................................................... 29FLOW SENSOR - MINIMUM FLOW CAPACITY ............................................................................................ 31SENSOR SELECTION.................................................................................................................................. 32SECTION VALVE TYPE.............................................................................................................................. 33PRESSURE REGULATING MODE ................................................................................................................ 34REGULATING VALVE CAPACITY............................................................................................................... 351 98-05051R1


854 Sprayer ControlREGULATING VALVE SPEED – COARSE ADJUSTMENT .............................................................................. 36REGULATING VALVE SPEED - FINE ADJUSTMENT .................................................................................... 37TANK VOLUME......................................................................................................................................... 38LOW TANK VOLUME ALARM ................................................................................................................... 38FILL FLOW METER CALIBRATION............................................................................................................. 39Manual Entry ...................................................................................................................................... 39Automatic Calibration......................................................................................................................... 39COMMUNICATIONS ................................................................................................................................... 41Printing Memory Contents.................................................................................................................. 41Using GPS Speed................................................................................................................................ 43Communicating With a Laptop Running Fieldware Software............................................................ 43Logging information to a Laptop Running Logging Software............................................................ 43SIMULATED GROUND SPEED .................................................................................................................... 44Low Speed .......................................................................................................................................... 44High Speed.......................................................................................................................................... 44How To Use........................................................................................................................................ 44AUTO MASTER OFF - SPEED ..................................................................................................................... 45MINIMUM PRESSURE SETTING.................................................................................................................. 45MAXIMUM PRESSURE SETTING................................................................................................................. 46AUDIBLE ALARM...................................................................................................................................... 46DUAL BOOM OFF SETTING ....................................................................................................................... 47DUAL BOOM ON SETTING........................................................................................................................ 48MEMORY RELOAD FUNCTION................................................................................................................... 49APPLICATION PRESET SETUP MODE .............................................................................................. 50TIP SPACING............................................................................................................................................. 50# OF TIPS PER BOOM SECTION ................................................................................................................. 51DENSITY................................................................................................................................................... 51Alternate Density Used ....................................................................................................................... 51Density Value ..................................................................................................................................... 51TIP SELECTION ......................................................................................................................................... 52TARGET APPLICATION RATE .................................................................................................................... 52CALCULATION STEPS................................................................................................................................53Known Pressure Calculation............................................................................................................... 53Known Speed Calculation................................................................................................................... 53OPERATING INSTRUCTIONS............................................................................................................... 54SPRAYER CHECKOUT................................................................................................................................54THE SPRAYING OPERATION...................................................................................................................... 56FEATURES................................................................................................................................................. 57AREA/VOLUME DISPLAY.......................................................................................................................... 57MEMORY FEATURE................................................................................................................................... 58Viewing Memory information ............................................................................................................ 58Clearing Memory Locations ............................................................................................................... 58Saving Information To Memory ......................................................................................................... 59Exiting the Memory Locations ........................................................................................................... 59TANK FEATURE ........................................................................................................................................ 60Tank Volume Feature ......................................................................................................................... 61APPLICATION ALARM............................................................................................................................... 62SENSOR LED ALARMS ............................................................................................................................. 62NO SPEED ALARM .................................................................................................................................... 63NO FLOW ALARM..................................................................................................................................... 63NO PRESSURE ALARM (only active if Pressure Transducer Installed is selected in System Setup).......... 64FLOW/PRESSURE DISCREPANCY ALARM .................................................................................................. 64BOOST MODE ........................................................................................................................................... 6598-05051 2R1


854 Sprayer ControlBoost Up ............................................................................................................................................. 65Boost Down ........................................................................................................................................ 65AUTO POWER DOWN ................................................................................................................................66SMART SENSING ....................................................................................................................................... 663 98-05051R1


854 Sprayer ControlIntroductionThe programming of the 854 is divided into three programming categories; OEMSetup Mode, System Setup Mode, and Application Preset Setup Mode.! The OEM Setup Mode contains configuration steps for the Console.Changing these settings is not recommended, unless instructed to do so, as itmay adversely affect the performance of the controller.! The System Setup Mode contains the programming steps that customize thecontroller to the sprayer or sprayer components. These include calibrationsteps and parameters that, once programmed, seldom change.! The Application Preset Setup Mode contains the settings that are mostfrequently changed: tip spacing, # of tips per boom section, density, nozzlesused, and target application rate.98-05051 4R1


Programming Guidelines854 Sprayer ControlMake sure that all hardware components are properly installed and tested.Before starting the programming process, confirm that the console and allsensors are working properly.IMPORTANT PRELIMINARY INFORMATIONBefore beginning, review the following Programming Guidelines that control theprogramming process:! To enter the program mode, see the appropriate program section in thismanual. The master switch must be in the off position to enter any programmode.! To exit any program mode press and hold thePRO key for 3 seconds. Theinputs are stored and the computer exits the program mode. This action canbe done at any time during the program process.! To increase the value of a programmable digit, press the + key. To decreasethe value, press the key. These keys are located directly to the right of thedisplay. For some programming steps, pressing and holding the + or keychanges the programmable value rapidly. Pressing the + or key oncechanges the value by one.! Pressing and holding the key in some programming steps sets the value to“0”.! Pressing the key once in some steps resets the value to the factory defaultvalue.! Pressing thePRO key advances to the next programming step. After the lastprogramming step, the console completes the program loop and returns tothe first programming step.Due to differences in fonts, some letters on the displays shown inthis manual are not identical with the corresponding letters on thedisplay of the controller. We tried to match them as close aspossible.5 98-05051R1


854 Sprayer ControlPowering Console On/OffPOWER ON" To power the 854 on, press thePROkey once." Initially the console displays thesoftware version at the top of thedisplay and the serial number of theconsole at the bottom of the display." After 5 seconds the display showsthe normal operating view.sft1.16H 2 8 0 3 1 2PTeeJet VisiFlo color coding only: For other tips see manualPOWER OFF" To manually power the console off,press the andPRO keyssimultaneously." The console then saves any newinformation (area and volumecounters) to memory and powers off.PTeeJet VisiFlo color coding only: For other tips see manualThe console also has an Auto Power Down feature. Refer to this in theFeatures section of this manual.98-05051 6R1


OEM Program Mode – TeeJet 854 Controller854 Sprayer ControlThe OEM Program Mode contains configuration steps for the console. Theconsole is typically pre-configured before being shipped. Changing these steps isnot recommended, unless instructed to do so, as it may adversely affect theperformance of the controller.To enter the OEM Program Mode:" Begin with console powered off." Press the andPRO keys simultaneously to turn the console off if necessary." Press and hold the + and keys. While holding, press thePRO key 4 times." Release all keys.NUMBER OF BOOM SECTION SWITCHES ON THE CONSOLEIn this step, program the number of individual boom section switches actuallypresent on the control console (regardless of the number of boom sections thatare on the sprayer)." Use the + or keys to modify thevalue." 1 to 11 switches can be programmed." This number determines the “Numberof spray Tips per Boom Section” in theSystem Setup Mode." Press and hold the key for 3seconds to set the value to 1." Press the key once to reset thisvalue to the default value of 5." Press thePRO key to accept the valueand advance to the next program step.N rS e c5PTeeJet VisiFlo color coding only: For other tips see manual7 98-05051R1


854 Sprayer ControlLANE WIDTH (GLM WORKING UNITS)When GLM is selected as the working units, this screen allows the operator toenter the lane width, in inches." Use the + or keys to modify thevalue." Press thePRO key to accept the valueand to advance to the next programstep.GLMLn144InchPTeeJet VisiFlo color coding only: For other tips see manualREGULATION PARAMETERSConfigure the regulation algorithm with the next 3 parameters.! Minimum Regulating Valve Voltage: this is the minimum voltage that candrive the regulating valve! Regulation Stop Band: this is the maximum allowed application rate error! Rotation Time of Regulating Valve: this is the total time required to closethe regulating valve at maximum speedThese three OEM parameters depend on the regulating valve used, and areexplained in more detail below.98-05051 8R1


Minimum Regulating valve Voltage854 Sprayer ControlThe Console uses variable voltages to drivethe regulating valve. Select the minimumvoltage that the regulating valve needs tomake it turn at its slowest rotation speed.Voltage on REGULATING VALVE14(E.g. if the motor of the regulating valveturns with a minimum of 3.5 volt, then thisnumber should be used here).The effect of this parameter on theregulation behavior is shown in Fig. 1. Thisvalue must match the actual operation ofthe regulating valve used. Check with thevalve manufacturer for this value." Use the + or keys to change thevoltage." Press and hold the key for 3seconds to set the value to 0.0." Press the key once to set the valueto the default value of 3.5 VoltThe standardTeeJet Regulating ValveMinimum Voltage is:3.5v3.50R e gM I nMinimum Regulation Voltage0 10 20 30 40 50 60 %Percentage of DEVIATION between TARGET and DOSE RATEFig. 1 Minimum Regulation Voltage3.5V o l tPTeeJet VisiFlo color coding only: For other tips see manualIf 12V is selected as minimum voltage then no variable voltage regulation isdone. Instead, a pulse regulation is done. This is necessary when using solenoidoperated regulating valves (e.g. a Ramsay valve).9 98-05051R1


854 Sprayer ControlRegulation Stop BandThe regulation stop band is the maximum error percentage allowed on theapplication rate before the regulating valve reacts. (E.g. if a stop band of 1.5% isselected, there is no action on the regulating valve if the actual application rate iswithin 1.5% of the target rate). This minimum percentage prevents the regulatingvalve from oscillating in a narrow band around the target point." Use the + or keys to change theregulation stop band (value isexpressed in error percentage). Themaximum value is 10.0%." Press and hold the key for 3seconds to set the value to 0.0." Press the key once to set the valueto the default setting of 1.5%." Press thePRO key to accept the valueand advance to the next regulationstep.R e gS t p1.5B a n dPTeeJet VisiFlo color coding only: For other tips see manualVoltage on REGULATING VALVE14The effect of this parameter on the regulationbehavior is shown in Fig. 2.0Regulation Stop Band0 10 20 30 40 50 60 %Percentage of DEVIATION between TARGET and DOSE RATEFig. 2 Regulation Stop Band98-05051 10R1


Rotation Time of Regulating Valve854 Sprayer ControlThis programming step selects the rotation time of the regulating valve. This timeis the number of seconds the regulating valve needs to turn from the completeclosed to the complete open position, at the nominal voltage (e.g. 14V)." Use the + or keys to change therotation time of the regulating valve inseconds (minimum 0s, maximum50s)." Press and hold the key for 3seconds to set the value to 0.0." Press the key once to set thevalue to the default setting of 6seconds." Press thePRO key to accept the valueand advance to the next regulationstep.R e gS p d6S e cPTeeJet VisiFlo color coding only: For other tips see manualThe standardTeeJet Regulating ValveRotation Time is:6 secondsThe Console uses this parameter to control the regulation speed. The value mustmatch the actual operation of the regulating valve used. Check with the valvemanufacturer for this value.11 98-05051R1


854 Sprayer ControlDISPLAY STABILIZATIONThis programming step stabilizes the Application rate being displayed duringminor adjustments of the control system. The controller continues to make thenecessary adjustments at all times. Enter the % of allowable change from thetarget rate in this step.E.g.: Target rate of 20 GPA with 5%programmed for Display Stabilization.Display shows 20 GPA any time theactual rate is +/- 5% or:19.0 - 21.0 GPA Actual = 20.0 GPA on display.S m oD I s" Use the + or keys to change thevalue." Press and hold the key for 3seconds to set the value to 0.0." Press the key once to set the value to the default setting of 5%." Press thePRO key to accept the value and advance to the next step." This value is limited to 20%. 0% disables this setting.5R a t ePTeeJet VisiFlo color coding only: For other tips see manualDATA DISPLAY SCREEN OPTIONSThe lower right hand display used during normal operating mode can becustomized to show:! Volume Sprayed! Area Covered! Both (alternating every 3 seconds)." Use the + or keys to change thedata to be displayed." Press thePRO key to accept the valueand advance to the next step.S h oD a tB o t h.PTeeJet VisiFlo color coding only: For other tips see manual98-05051 12R1


854 Sprayer ControlCALIBRATE TIP LEVEL %If both a pressure sensor and flow meter are installed and being used, the 854uses one sensor to cross check the other for system errors.Select the primary sensor (used for regulation) in the Sensor Select step of theSystem Setup Mode. The opposite sensor automatically does the crosschecking.This step sets the % of allowable errorbetween the sensors before an alarm isactivated. All sprayer systems havesome discrepancy between pressureand flow due to pressure drops andpositioning of the sensors." Use the + or keys to change the% of allowable error." Press thePRO key to accept the valueand advance to the next step.C a lT I p5 0L e vPTeeJet VisiFlo color coding only: For other tips see manualIt is recommended that this value be left at50%Unless instructed otherwise.13 98-05051R1


854 Sprayer ControlDIGITAL OUTPUT #2The primary output from the consolecomputer drives the pressure regulatingvalve. A second output is available andcan be configured for the followinguses.! Not Used – The second digitaloutput is not used.O U TN O T2U S E D! Dual Boom – Used to control a shutoff valve, on a second boom line,that is automatically activated basedon speed or pressure.! Fill Valve – Used to automaticallyshut off a valve or switch, during atank filling operation, when used witha tank fill flow meter." Use the + or keys to change thevalue." Press thePRO key to accept the valueand advance to the next step.PTeeJet VisiFlo color coding only: For other tips see manualO U TD u a2B o o mTeeJet VisiFlo color coding only: For other tips see manualPO U TF I l2V a l vPTeeJet VisiFlo color coding only: For other tips see manual98-05051 14R1


854 Sprayer ControlDUAL BOOM REGULATION MODE*********** THIS STEP MAY NOT APPEAR ***********This step only appears ifDUAL BOOMwas selected in theDIGITAL OUTPUT #2 step.Regulate the dual boom feature by eitherspeed (SPD) or pressure (PRS).! E.g. When you reach X MPH (Km/h)the second boom line turns ON/OFF! E.g. When you reach X PSI (bar) thesecond boom line turns ON/OFF" Use the + or keys to change thevalue." Press thePRO key to accept the valueand advance to the next step.D bR e gP r sM o d ePTeeJet VisiFlo color coding only: For other tips see manualThe selected value determines howprogramming steps appear in the SystemSetup Mode.Specific speed or pressure values,to be used during operation, areselected in the System Setup Mode.D bR e gS p dM o d ePTeeJet VisiFlo color coding only: For other tips see manual15 98-05051R1


854 Sprayer ControlFILL VALVE DEFAULT*********** THIS STEP MAY NOT APPEAR ***********This step only appears ifFILL VALVEwas selected in theDIGITAL OUTPUT #2 step.This step indicates the normal operating state of the fill valve being used.! If the fill valve requires a +12V signalduring the spraying operation, thevalve default = ON.! If the fill valve requires a +12V signalduring the filling operation, the valvedefault = OFF" Use the + or keys to change thevalue." Press thePRO key to accept the valueand advance to the next regulationstep.F I lO f fO u tD f l tPTeeJet VisiFlo color coding only: For other tips see manualAUTO POWER DOWN TIMEThe 854 console is designed to automatically power down after 10 minutes withno activity from the sensors or operator.The length of time can be adjusted in thisstep." Use the + or keys to change thepower down time" Press thePRO key to accept the valueand advance to the next regulationstep.If Power Off Time = 0Auto Power Down Feature isdisabledP w rO f f1 0T I m ePTeeJet VisiFlo color coding only: For other tips see manual98-05051 16R1


854 Sprayer ControlTEEJET COMMUNICATION SYSTEM (TCS) CONFIGURATIONIf the TeeJet Communication System (TCS) package was NOT purchased for thisconsole, the next 2 programming steps do not pertain to your spraying operation. Ifthis is the case these values should be left at the default settings.Job Operating System! Job No – (DEFAULT) Console usesapplication parameters entered by theoperator only! Job Only – Console uses applicationparameters entered from the TeeJetCommunication System only! Job Both – Console acceptsapplication parameters from both theoperator and the TeeJetCommunication SystemJ o bN 0PTeeJet VisiFlo color coding only: For other tips see manual" Use the + or keys to change the value." Press thePRO key to accept the value and advance to the next regulation step.Console Identification #The TeeJet Communication System (TCS) is capable of monitoring andcommunicating with several consoles at one time. Therefore each consolecommunicating with a single TCS must be assigned a unique identification #.DEFAULT = 1" Use the + or keys to change thevalue." Press thePRO key to accept the valueand advance to the next regulationstep.C o nI d1PTeeJet VisiFlo color coding only: For other tips see manual17 98-05051R1


854 Sprayer ControlMAXIMUM SPEED ACHIEVEDThis feature records the maximum speedachieved by the sprayer.This value can only be cleared by anauthorized TeeJet Dealer, Distributor, orRepresentative." Press thePRO key to advance to thenext step.S p dMPH1 5.8 H I g hPTeeJet VisiFlo color coding only: For other tips see manualHIDDEN AREA COUNTERThe Hidden area counter can only beviewed and cleared in this step.This value can only be cleared by anauthorized TeeJet Dealer, Distributoror Representative." Press thePRO key to advance to thenext step.T o tAr1 4 8 0 AcPTeeJet VisiFlo color coding only: For other tips see manualHIDDEN VOLUME COUNTERThe Hidden volume counter can onlybe viewed and cleared in this step.This value can only be cleared by anauthorized TeeJet Dealer, Distributor,or Representative." Press thePRO key to advance to thenext step.T o t VOL4630VOLPTeeJet VisiFlo color coding only: For other tips see manual98-05051 18R1


854 Sprayer ControlPRESSURE TRANSDUCER CALIBRATION (P HI)***********THIS STEP MAY NOT APPEAR***********If the console has not been previously programmed in theSystem Setup Mode for use with a pressure sensor.*****WARNING**********WARNING**********WARNING*****We do NOT recommend that you run this calibration procedure initially. You shouldONLY run it if a known pressure drop exists between the Pressure Transducer andthe spray tips and if a TeeJet representative recommends doing so.The pressure sensor can be autocalibrated to compensate for pressure lossbetween the pressure transducer and thespray tips.1 4 5PSIP r sP h iS e n sTeeJet VisiFlo color coding only: For other tips see manualP" Press and hold the + and keys tostart the Auto Calibration process. Thelower left hand screen goes blank" Place an accurate manual pressuregauge in the spray line, as close to thespray tips as possible." Activate the pump and boom sectionsto be used for calibration." Turn the Master switch ON" Use the + or keys to adjust thepressure on the manual pressure7 5PSI1 6.22 0 6PTeeJet VisiFlo color coding only: For other tips see manual19 98-05051R1


854 Sprayer Controlgauge, near the tips, to the desired pressure to be used for calibration. Thehigher the pressure the better." Turn the Master switch off." Use the + or keys to adjust the displayed pressure to match the actualcalibration pressure." Activate the pump and boom sections to be used for calibration." Confirm that the actual pressure matches the displayed pressure." Press thePRO key to start calibration." The console counts 0-10 during thecalibration.1 1 2PSIP h i1 - 10 S e n sPTeeJet VisiFlo color coding only: For other tips see manualYour new Pressure Transducer MaximumRating is displayed." This value is automatically carried overto the System Setup Mode." Press thePRO key to advance to the nextstep.1 1 2PSIP r sP h iS e n sTeeJet VisiFlo color coding only: For other tips see manualP98-05051 20R1


854 Sprayer ControlMEMORY SAVE FUNCTIONAllows you to save a custom set ofprogramming parameters. Typically youwould do this after you have completedall 3 programming sections for theconsole.Selecting YES at this step saves allprogram settings to memory. Thesesettings can be recalled in the SystemSetup Mode at the Mem Load functionstep.You typically use this function to get theconsole back to a starting point afterunknown changes have been made tothe program modes." Use the + or keys to select eitherYES or NO" Press thePRO key to advance to thenext step.M e mN oS a v ePTeeJet VisiFlo color coding only: For other tips see manualM e mY e sS a v ePTeeJet VisiFlo color coding only: For other tips see manual! This completes the OEM programming of the TeeJet 854. Press thePRO keyagain to return to the beginning step.! Press and hold thePRO key to exit and save the OEM setup mode.! This can be done at any time during OEM programming.! The console exits the OEM program mode to the normal operating mode.21 98-05051R1


854 Sprayer ControlSystem Setup Mode – TeeJet 854 ControllerThe System Setup Mode contains the programming steps that customize thecontroller to the sprayer or sprayer components. These include calibration stepsand parameters that, once programmed, seldom change.To enter the Program Mode, start from the normal operating mode and press andhold thePRO key for 3 seconds. The first programming step appears on the display.SELECTION OF WORKING UNITSIn this step, select the desired units.The 854 is capable of working in:! US (US Gallons Per Acre)! trf (Turf) (US Gallons /1000ft2)! IMP (Imperial Gallons Per Acre),! nh3 (lbs. Of N Per Acre)! GLM (US Gallons Per Lane Mile)! SI (Metric Liters Per Hectare)" Use the + and keys to selectthe appropriate units." Press thePRO key to accept thevalue and advance to the nextprogram step.usunitPTeeJet VisiFlo color coding only: For other tips see manual98-05051 22R1


854 Sprayer ControlRESET TO DEFAULTS***********THIS STEP MAY NOT APPEAR***********If no changes were made to the units, this step is skipped and setupautomatically advances to the Speed Sensor Calibration Step.If you made changes to the units in thefirst programming step, before advancingto the next step, the console asks if allthe program parameters should be resetto defaults specified for the units chosen.resyes" Use the + or key to select eitheryes or no." Press thePRO key to reset parametersand/or advance to the next step.us dfltPTeeJet VisiFlo color coding only: For other tips see manualSPEED SENSOR CALIBRATIONDuring Speed Calibration, the 854 automatically senses whether a WheelSpeed or Radar Speed Sensor is being used.Proximity / Magnetic PulsesThe speed sensor must be calibrated toprovide the proper speed and areareadings. The value for this step is thenumber of pulses generated by the speedsensor in 300 ft.spdcal250PTeeJet VisiFlo color coding only: For other tips see manual23 98-05051R1


854 Sprayer ControlAutomatic Calibration:" Mark off a distance of exactly 300 ft." Press and hold the + and keyssimultaneously for 3 seconds toactivate the auto calibration mode.When the auto calibration mode isactivated, “CAL” is displayed at thelower right of the display." Start driving toward the start point ofthe of 300 ft. (100 meter) course." As you cross the start point, press the+ key once to begin the calibrationprocess." As you continue over the course, the854 counts the pulses generated." As you cross the end point, press the+ key once. The number displayed isthe speed calibration number." If the console determines that a radarspeed sensor is connected, it displays“rAd” in the lower left part of thedisplay.calPTeeJet VisiFlo color coding only: For other tips see manualThe speed driven over the course isnot important.The auto speed calibration processshould take place with the sprayertank ½ full.It is best to perform the automatic speed calibration process at least twiceand use the average of the speed calibration numbers.To manually enter the radar calibration value, press thePRO and + keyssimultaneously, to put the console into radar mode. When the controlconsole is in the radar mode, it displays “RAD” in the lower left part of theconsole display. Now use the + or keys to adjust the value. Pressing theAuto/Man key resets the speed calibration to the default value." When the correct value has been entered, press thePRO key to validate thisvalue and advance to the next step.98-05051 24R1


854 Sprayer ControlWhen the auto calibration mode is activated, no other functions are possibleuntil the console receives speed pulses for calibration. To deactivate theauto calibration mode, press the + key until a number is displayed..DISTANCE COUNTERThis step is a feature, not a calibration step. No specific value must be enteredhere for the controller to operate correctly." This feature measures distance in feet(meters)." It can be used to confirm AutomaticSpeed Calibration (see note below)." To activate the counter, turn theMaster Boom Switch on." To avoid actually spraying duringthis task, toggle the individualboom sections off." To stop the counter, turn the MasterBoom Switch off." To clear an existing distance value,press and hold the key for 3 seconds.dstftctr 4 5 6TeeJet VisiFlo color coding only: For other tips see manualPTo confirm Automatic Speed Calibration, first complete the calibrationprocedure. Advance to Distance Counter step. Drive across the same 300 footcourse turning the Master Switch ON at the start point and OFF at the finishpoint. Distance measured should be 300 feet (+/- 6 feet).25 98-05051R1


854 Sprayer ControlPRESSURE HOLD?If GLN is selected for Working Units, this step appears instead of thePressure Sensor Installed step below.This setting determines whether thesprayer holds a constant pressure,regardless of ground speed, or adjuststhe pressure according to ground speed.P r s" Use the + or key to select YES orNO." Select YES to have the sprayer hold aconstant pressure." Select NO to have the sprayer toadjust the pressure according to theground speed." Press thePRO key to accept the value and advance to the next step.OFFHoldPTeeJet VisiFlo color coding only: For other tips see manualPRESSURE SENSOR INSTALLED?If NO is selected in this step, the next 2 steps in the manual do not appear in theconsole programming selection.This step indicates to the consolewhether a pressure sensor has beeninstalled on the sprayer." Use the + or key to select YES orNO." Select YES if a pressure transducer isinstalled" Select NO if a pressure transducer isNOT being used." Press thePRO key to accept the valueand advance to the next step.P r sY e sS e n sTeeJet VisiFlo color coding only: For other tips see manualP98-05051 26R1


854 Sprayer ControlPRESSURE TRANSDUCER LOW PRESSURE CALIBRATION (P REF)This step is used to calibrate the “0”pressure setting of the pressuretransducer installed in your system. Thepressure transducer used with the 854 isa current type transducer and uses a 4-20 mA reading. 4.0 mA represents 0pressure.PSI0R e f4.00M aPTeeJet VisiFlo color coding only: For other tips see manualAutomatic Calibration" Make sure that the sprayer pump isturned off and that there is absolutelyno pressure in the system (releasepressure held by boom control valvesand nozzle body check valves)." In some cases it may be best toremove the sensor from the plumbingsystem to complete the calibration." Press and hold the + and keyssimultaneously for 3 seconds toactivate the auto-calibration feature." The lower left portion of the displaycounts 1-10 during the calibration." When the display finishes counting, itshould display a number close to 4.0(+/- 0.2)." The low pressure value of thetransducer is now calibrated." Press thePRO key to advance to thenext step.PSI04.0 01-1 0 8 8PTeeJet VisiFlo color coding only: For other tips see manualPSI0R e f4.1 3M aTeeJet VisiFlo color coding only: For other tips see manualP27 98-05051R1


854 Sprayer ControlPRESSURE TRANSDUCER MAXIMUM RATING (P HI)This step is used to set the maximum rating of the pressure transducer in thesystem. This number can be found stamped on the pressure transducer itself." If the transducer has a maximumrating of 145 psi (10 bar), and thatnumber is shown in the display,advance to the next step by pressingthePRO key." If however, the maximum rating is 363psi (25 bar), use the + or keys tochange the value." Press thePRO key to advance to thenext step.1 4 5PSIP r sP h iS e n sPTeeJet VisiFlo color coding only: For other tips see manualDo not set this value to zero; even if no pressure sensor is installed.The Maximum Pressure can not be set lower than the Minimum Pressure.FLOW METER SENSOR INSTALLED?***********THIS STEP MAY NOT APPEAR***********If other programming steps have indicated that a flow sensor IS present.**" This step indicates to the consolewhether a flow meter has beeninstalled on the sprayer." Use the + or keys to adjust thevalue." Select YES if a flow meter is installedor NO if a flow meter not used." Press thePRO key to accept this valueand advance to the next step.Y e sF l o S e n sPTeeJet VisiFlo color coding only: For other tips see manual98-05051 28R1


854 Sprayer ControlFLOW METER PULSES***********THIS STEP MAY NOT APPEAR***********It only appears if the Flow Meter Installed step is set to YES.In this step you can enter the flow metercalibration number manually from thefactory calibrated tag, or start an autocalibrationprocedure to determine theflow meter pulses based on a knownvolume of fluid.! The auto-calibration procedure isrecommended for maximumaccuracyF l oC a lP l s 6 5 0.0PTeeJet VisiFlo color coding only: For other tips see manualManual Entry" First locate the factory calibrated flowmeter pulse rate tag on the flowmeter." If this varies from the default value (itusually does) of the console, use the+ or keys to modify the value." Press thePRO key to advance to thenext step.Automatic CalibrationC a lPTeeJet VisiFlo color coding only: For other tips see manualTo complete an automatic calibration of the flow meter:" Press and hold the + and keyssimultaneously for 3 seconds. Thisclears the existing value and initiatesthe calibration procedure." “CAL” is displayed on the screen. Thisindicates that the controller is ready tobegin the calibration process." Engage the sprayer pump." Push the + key to activate thecalibration.C a l0PTeeJet VisiFlo color coding only: For other tips see manual29 98-05051R1


854 Sprayer Control" Turn the boom sections on and beginspraying a known volume of fluid (e.g.100 gallons)." As the known amount is sprayed, theconsole counts the pulses." After the known volume has beensprayed, turn the Master switch off tostop counting pulses.C a l5 6 3 8 5 6PTeeJet VisiFlo color coding only: For other tips see manual" Press thePRO key. The console nowasks what volume was sprayed." Use the + and keys to adjust thevalue to match the volume sprayed ingallons (liters)." Press thePRO key to return to theprogramming mode." The console displays the new flowmeter calibration number." To accept this value, press thePRO keyto advance to the next step." If you are going to repeat thecalibration procedure, refer to the steps above.G a l1 0 0 0 VolPTeeJet VisiFlo color coding only: For other tips see manualA volume of at least 50gallons (200 liters) should besprayed during calibration.The more volume used forcalibration, the more accuratethe flow meter is.98-05051 30R1


854 Sprayer ControlFLOW SENSOR - MINIMUM FLOW CAPACITY***********THIS STEP MAY NOT APPEAR***********If the console has not been previously programmed foruse with a pressure sensorWhen both a pressure and flow sensor are installed, the 854 determines whenthe flow rate has dropped below the capacity of the flow meter being used andautomatically switches to pressure based regulation. When the flow rate againreaches an acceptable level for the flow meter to regulate, the 854 automaticallyswitches back to flow based regulation." Use the + or keys to enter theminimum recommended flow rate, inGPM (LPM), of the flow meterinstalled on the sprayer." This information can be found in theflow meter manufacturer’s literature." Minimum flow rates for TeeJet flowmeters are listed in the table below." Press thePRO key to accept the valueand advance to the next step.F l oL o5.0S e n sPTeeJet VisiFlo color coding only: For other tips see manualNominal FlowMeter SizeMinimum Flow RateIn GPM (l/min)½” 0.79 GPM (3 l/min)¾” 1.9 GPM (7 l/min)1” 2.6 GPM (10 l/min)801-PP-RUB2.5 GPM (9.5 l/min)1 ½” 9.2 GPM (35 l/min)2” 19 GPM (72 l/min)31 98-05051R1


854 Sprayer ControlSENSOR SELECTION***********THIS STEP MAY NOT APPEAR***********It only appears if both sensors (pressure and flow sensors) havebeen installed and programmed.The 854 system can be used with either a flow meter, pressure transducer orboth. This step tells the console which type(s) of sensor is being used to controlthe regulation." Use the + or key to select either“FLO” for flow meter or “PrS” forpressure sensor." Press thePRO key to advance to thenext step.R e gF l oIf both sensors are installed on thesprayer, this step determines which is theprimary sensor for regulation. If “FLO” isselected, the flow meter is used to controlflow and the pressure transducer is usedonly to display the actual pressure. If “PRS”is selected, the pressure transducer is used to control the flow and display theactual pressure.PTeeJet VisiFlo color coding only: For other tips see manual98-05051 32R1


854 Sprayer ControlSECTION VALVE TYPEThis step distinguishes the type of on-off boom control valves installed on themachine. There are 2 types of valves that can be used; 2 way and 3 way.! A 2 way control valve is simply an on/off valve. Flow is either directed to theboom section(s) or it is blocked.! A 3 way control valve is known as a by-pass valve. Flow continuously passesthorough this valve. When the valve is activated (on), flow is directed to theboom section(s). When the valve is not activated (off), flow is directed througha bypass port, back to the supply tank." Change the value, if needed, bypressing the + or keys." Press thePRO key to accept the valueand advance to the next step.S e c2T y p ePTeeJet VisiFlo color coding only: For other tips see manual33 98-05051R1


854 Sprayer ControlPRESSURE REGULATING MODEThis step tells the 854 where the regulating valve is plumbed into the system.Once set correctly, this value should not change unless the regulating valve isphysically moved to a new point in the plumbing." The default value “BYP” indicates thatthe pressure regulating valve isplumbed in a bypass line." If this is correct press thePRO key toaccept the value and advance to thenext step.R e gB y pWhen programmed in the bypassmode, with the controller in “MAN”mode, the pressure regulatingvalve should:! close when the + key ispressed! open when the key ispressedPTeeJet VisiFlo color coding only: For other tips see manualIf the pressure regulating valve is plumbedin a supply line to the booms, this isconsidered a throttling position." Use the + or key to change thevalue to “thr” (throttling mode)." By doing this, the polarity, that theconsole uses to control the regulatingvalve, is reversed." Press thePRO key to advance to the nextstep.R e gT h rPTeeJet VisiFlo color coding only: For other tips see manualWhen programmed in thethrottling mode with the controllerin “MAN” mode, the valve should! open when the + key ispressed! close when the key ispressed98-05051 34R1


854 Sprayer ControlREGULATING VALVE CAPACITYEnter the maximum flow capacity of theregulating valve, in Gallons Per Minute(GPM). The regulating parametersneeded to drive the regulating valvesmoothly depend on the size of thevalve. This step optimizes theseparameters for the size of valve beingused." Use the + or keys to adjust thevalue so that it matches the maximumflow capacity (GPM) of the regulatingvalve being used." Press thePRO key to advance to the nextstep.Reference the valvemanufacturer’sliterature to determinethe flow capacity of theregulating valve.R e gGPMGPMC a p 32PTeeJet VisiFlo color coding only: For other tips see manualCommon TeeJet Regulating Valves344AE-2RL ....................27 GPM344AE-2RB ....................30 GPM344AE-2PR ....................12 GPMAA346ZR .......................85 GPMAA346ZRB.....................85 GPM35 98-05051R1


854 Sprayer ControlREGULATING VALVE SPEED – COARSE ADJUSTMENTThis step allows the adjustment of the pressure regulating valve speed, toaccommodate different application needs. Operating conditions may necessitatea higher or lower response speed for the regulating valve.The coarse adjustment controls thespeed of the valve when largeadjustments in flow are required by thecontroller." Use the + or keys to increase ordecrease the response time." Any number between 0 and 19 maybe selected.R e gS p d1 0C o a r0 = Slow : 19 = FastPTeeJet VisiFlo color coding only: For other tips see manualIf the regulating valve is plumbed in a by-pass line, the valve speed coarseadjustment number of 15 works very well in most applications.If the regulating valve is plumbed in the throttling position (supply line), startwith a valve coarse adjustment speed number of 5 and adjust the numberaccording to application requirements." Press thePRO key to accept the value and advance to the Fine Adjustmentsetting.98-05051 36R1


REGULATING VALVE SPEED - FINE ADJUSTMENT854 Sprayer ControlThe fine adjustment controls the speed of the valve when small adjustments inflow are required by the controller." Use the + or keys to increase ordecrease the response time." Any number between 0 and 9 may beselected.0 = Slow: 9 = FastStart with a fine adjustment speed of 2.This works well in most situations. Thisnumber may need to be optimizedduring the spraying operation.R e gS p d2F I n ePTeeJet VisiFlo color coding only: For other tips see manual" To accept your Fine Adjustment Speed Factor and advance to the next step,press thePRO key.Adjusting agitation volumes can often assist the regulating valve operation.This speed value can be adjusted to optimize system performance.If you notice that the valve seems to “search” for the programmedapplication rate by cycling the pressure up and down continuously, reducethe number until the “searching” is minimized or eliminated. Conversely, ahigher number increases the valve response speed and speed up the rateof adjustment.37 98-05051R1


854 Sprayer ControlTANK VOLUMEIn addition to accumulating the total volume applied, the 854 counts the volumedown from the maximum tank contents to 0 gallons (liters). This allows themonitoring of the volume remaining in the tank." Use the + and keys to enter themaximum volume of the sprayer tankin gallons (liters)." Press thePRO key to accept the valueand advance to the next step.Tank volume markings are notalways accurate. Maximum tankvolume should be checked witha fill flow meter or by weight1 0 0 0 VolPTeeJet VisiFlo color coding only: For other tips see manualLOW TANK VOLUME ALARMThe TeeJet 854 console alerts theoperator when nearing the end of a tank." Use the + or key to enter thevolume at which the console shoulddisplay the alert. A value of 0 willdisable this feature.A visual alarm is displayed when the lowtank level warning is reached. See theFeatures - Tank Volume Section for moredetailsL O 2 5VolPTeeJet VisiFlo color coding only: For other tips see manual98-05051 38R1


854 Sprayer ControlFILL FLOW METER CALIBRATIONThe TeeJet 854 has the capability of reading signals from a second flow meterfor tank filling purposes. This feature must be activated by the organizationselling this console kit and requires an additional flow meter. You can alsoconnect the 854 to a valve or switch, for automatic shut off of the filling operation.Manual Entry***********THIS STEP MAY NOT APPEAR***********unless the console has been previously programmed foruse with a fill flow meter" First locate the factory calibrated tag onthe flow meter." If this varies from the default value (itusually does), use the + or keys tomodify the value." Press thePRO key to advance to the nextstep.Automatic CalibrationTo perform an automatic calibration of theflow meter:" Press and hold the + and keyssimultaneously for 3 seconds. This clearsthe existing value and initiates thecalibration procedure." “CAL” is displayed in the screen. Thisindicates that the controller is ready tobegin the calibration process.FIL FLOPLS 65.00TeeJet VisiFlo color coding only: For other tips seeC a lTeeJet VisiFlo color coding only: For other tips seePP" Push the + key to activate thecalibration." Now begin pumping a known volume offluid (e.g. 100 gallons/liters) through theflow meter into the tank.C a l0TeeJet VisiFlo color coding only: For other tips see39 98-05051R1P


854 Sprayer Control" As the known amount is pumped, theconsole counts the pulses." After the known volume has beenpumped, turn the pump (or flow) off tostop counting pulses.C a l5 6 3 8 5 6PTeeJet VisiFlo color coding only: For other tips see manual" Press thePRO key." The console now asks what volumewas pumped." Use the + and/or keys to adjustthe value to match the volumepumped (in gallons/liters).G a l1 0 0 0 VolPTeeJet VisiFlo color coding only: For other tips see manual" Press thePRO key to return to theprogramming mode." The new flow meter calibrationnumber is displayed." Press thePRO key to accept this valueto advance to the next step.If you are going to repeat the calibrationprocedure, refer to the steps above.FIL FLOPLS 67.00TeeJet VisiFlo color coding only: For other tips seePTo achieve an accurate flow meter calibration, a volume of at least 50 gallons(200 liters) should be pumped during calibration. The more volume used forcalibration the more accurate the flow meter is.98-05051 40R1


854 Sprayer ControlCOMMUNICATIONSThis step allows the selection of the type of communication being used (if any).The choices available are:! “no con” (no external communications)! “prt” (Memory printing)! “gps” (Global Positioning System /Variable Rate communication capability)! “log” (Downloading to a PC on the gocapability)! “pc” ( PC link)." Use the + and keys to select the typeof communication being used." Press thePRO key to advance to the nextstep.PRTPTeeJet VisiFlo color coding only: For other tips see manualPrinting Memory Contents" Connect the 854 console to the 78-20002printer using a 45-20064 printer cable(w/power)." Select PRT in the Communications Setupstep." The Boom Master Switch must be OFF." Press the MEM key. The first screen is theMEM PRN screen." Press thePRO key to advance to the nextstep.MEMPRNTeeJet VisiFlo color coding only: For other tips seeP! Only information stored in the memorylocations can be printed." Press the MEM key to bring up the PRN totscreen, which allows you to print thecontents of the “Total” memory location.and any individual memory locations (1 –9) that contain data.PRNtotTeeJet VisiFlo color coding only: For other tips seeP41 98-05051R1


854 Sprayer Control" Continue pressing the MEM key to displayscreens 1 – 9, which represent memorylocations 1 – 9." When the desired location is displayed,press thePRO key to print the report.PRN3TeeJet VisiFlo color coding only: For other tips seePThe result is a printed report similar to one ofthose shown to the right." To exit from the Print Menu, press and holdeither the MEMkey or thePRO key to return tothe Memory Menu.- - - - - - - - - - - - - - - -Spraying Report 999- - - - - - - - - - -- - - - - -Date : 4-26-04 13:05Field : ____________Operator : _________- - - - - - - - - - - - - - - -Target : 20.0 GPATip : 4- - - - - - - - - - - - - - - -Volume : 8 GALArea : 0.6 AcMean rate: 13.3GPAAv. Speed: 10.4 mph- - - - - - - - - - - - - - - -Chem1 : _________Chem2 : _________Chem3 : _________Chem4 : _________Chem5 : _________- - - - - - - - - - - - - - - -Wind speed : _______Temperature: ______Humidity : ______- - - - - - - - - - - - - - -REM : ________________________________________________- - - - - - - - - - - - - - - -Summary Report 999- - - - - - - - - - -- - - - - -Date : 4-26-04 13:05- - - - - - - - - - -- - - - - -Memory totalVolume : 17.6 GALArea : 16.1 AcMean rate: 0.0 GLMAv. Speed: 17.0 mph- - - - - - - - - - - - - - - -Memory 1Volume : 1.8 GALArea : 0.6 AcMean rate: 3.3 GPAAv. Speed: 7.4 mph- - - - - - - - - - - - - - - -Memory 2Volume : 3.4 GALArea : 3.4 AcMean rate: 1.0 GPAAv. Speed: 6.8 mph- - - - - - - - - - - - - - - -Memory 3Volume : 5.5 GALArea : 4.6 AcMean rate: 1.2 GPAAv. Speed: 6.2 mph- - - - - - - - - - - - - - - -Memory 4Volume : 2.5 GALArea : 3.1 AcMean rate: 0.8 GPAAv. Speed: 7.1 mph- - - - - - - - - - - - - - - -Memory 5Volume : 4.4 GALArea : 4.4 AcMean rate: 1.0 GPAAv. Speed: 7.0 mph- - - - - - - - - - - - - - - -98-05051 42R1


Using GPS Speed854 Sprayer Control! The GPS receiver must be sending theGPSGPVTG string at 9600 Baud with asampling rate of 1 Hz. It is OK if otherstrings are being sent also." Connect the GPS receiver to the 854console using a 45-20063 serial cable." Select GPS in the communication setupstep.! When the 854 console starts receivingspeed information from the GPS receiver,it uses that information for determining vehicle speed. If the 854 console losescommunication with the GPS receiver for more than 5 seconds, it revertsback to other sources of speed input.TeeJet VisiFlo color coding only: For other tips seePCommunicating With a Laptop Running Fieldware Software" Connect the laptop to the 854 console,using a 45-20063 serial cable." Select PC in the communication setupPCstep." Press thePRO key to advance to the nextstep." The GPS Speed step appears only if PC wasselected in the Communications Setupstep. Select ON to receive GPS speedthrough the laptop. Select OFF to use theregular radar or speed sensor input." Follow the instructions in the Fieldware manual to set up and run the ARMfunction. In System/System Setup /Control, select the TeeJet854.DRV driver.TeeJet VisiFlo color coding only: For other tips seePLogging information to a Laptop Running Logging Software" Connect the laptop to the 854 consoleusing a 45-20063 serial cable." Select LOG in the communication setupstep.! The LOG mode is an advanced data transfertool used with specially configured hardwaredevices only. This mode is not used in normalapplications.LOGTeeJet VisiFlo color coding only: For other tips seeP43 98-05051R1


854 Sprayer ControlSIMULATED GROUND SPEEDSimulated ground speed allows the verification of the functions of the consoleand of the sprayer, spraying water, without actually moving the sprayer. Thisshould be done prior to any spraying activity.The 854 has a low and high simulated ground speed. This allows switchingbetween the two to simulate a speed change to ensure the console is regulatingproperly during the Sprayer Checkout.Low Speed" Use the + and keys to adjust thevalue." Press thePRO key to advance to theHigh Simulated speed step.High Speed" Use the + and keys to adjust thevalue." Press thePRO key to advance to thenext programming step.How To UseTo activate the simulated speed, while inthe normal operating mode with themaster switch ON" Press thePRO and keys for lowsimulated speed" Press thePRO and + keys for highsimulated speed.S I nS p dMPH6.0 L oPTeeJet VisiFlo color coding only: For other tips see manualS I nS p dMPH9,0 H I g hPTeeJet VisiFlo color coding only: For other tips see manualOnce the sprayer begins moving and the 854 receives actual speed pulses, thesimulated speed feature is deactivated. If a Radar Speed Sensor is being used,disconnect the Radar connection from the main console. Because of thesensitivity of this speed sensor, any movement can disable simulated speed.98-05051 44R1


854 Sprayer ControlAUTO MASTER OFF - SPEEDThe TeeJet 854 automatically shuts the boom sections off at the speedprogrammed. This eliminates an operator function when slowing to stop or turnaround." Use the + or keys to adjust thespeed value." Press thePRO key to advance to thenext step.When the sprayer speed exceeds thisspeed, the boom sections turn back on.M I n0.0MPHS p dSet this value to 0 to disable thisfeature.PTeeJet VisiFlo color coding only: For other tips see manualThis feature is disabled when operating in Manual Mode.MINIMUM PRESSURE SETTINGSet the minimum pressure that the sprayer is allowed to regulate to. Sometimeswhen the sprayer speed slows down, the control system regulates the pressureso low that it falls below the manufacturer’s recommended pressure for the spraytip or reduces system flow to the point where the flow meter stalls.This is typically set to the minimumrecommended pressure range for thespray tips being used." Use the + or keys to adjust theminimum pressure." Press thePRO key to advance to thenext step.I.e. If this step is set to 15 psi (1.0 bar)the console, in automatic mode, doesnot regulate pressure below 15 psi (1.0bar).Audible Alarm(Steady beep – Medium Priority)Activates with this featureif enabled1 0PSIL oR e gP r sPTeeJet VisiFlo color coding only: For other tips see manual45 98-05051R1


854 Sprayer ControlMAXIMUM PRESSURE SETTINGSet the maximum pressure that the sprayer is allowed to regulate to. This helpsensure that the spraying pressure does not go beyond the recommendedpressure range of the spray tips being used." Use the + or keys to adjust themaximum pressure." Press thePRO key to advance to thenext step.This step can be used to help preventspraying applications that contribute todrift.Audible Alarm(Steady beep – Medium Priority)Activates with this featureif enabled1 4 5PSIH iR e gP r sPTeeJet VisiFlo color coding only: For other tips see manualAUDIBLE ALARMThe audible alarm is used to alert the operator to problems with the sprayercontrol system. It is used in addition to visual alarms on the LCD display and LEDsensor alarms above the screen." To activate the audible alarm use the+ or keys to chose YES." To deactivate the audible alarm usethe + or keys to chose NO." Press thePRO key to advance to thenext step.A u dY e sA l r mTeeJet VisiFlo color coding only: For other tips see manualPThe audible alarms are divided into three priorities:LOW – A long beepMedium – A steady beepHigh – Three short beeps98-05051 46R1


854 Sprayer ControlDUAL BOOM OFF SETTING***********THIS STEP MAY NOT APPEAR***********It is only present if the Dual Boom option was selected in theOEM programming mode.This dual boom option is the speed or pressure at which the second boom isshut off. As the vehicle slows down the system pressure begins to drop,eventually to a point where the spray tips are no longer able to develop a pattern.The Dual Boom Off Setting should be adjusted to shut off the second boom linebefore this occurs." Use the + or keys to adjustthe setting." Press thePRO key to advance tothe next step.D bS p dMPH6.0 offTeeJet VisiFlo color coding only: For other tips see manualDual Boom Off - SpeedP15PSIprsdbloTeeJet VisiFlo color coding only: For other tips see manualDual Boom Off - PressureP47 98-05051R1


854 Sprayer ControlDUAL BOOM ON SETTING***********THIS STEP MAY NOT APPEAR***********It is only present if the Dual Boom option was selected in theOEM programming mode.This dual boom option is the speed or pressure at which the second boom isturned on. As the speed increases the system pressure eventually reaches themaximum recommended pressure for the spray tips being used. Driving faster(increasing pressure) results in the tips creating drift prone droplets. The DualBoom On setting should be adjusted to turn the second boom line on before thishappens." Use the + or keys to adjust thesetting." Press thePRO key to advance to thenext step.D bS p dMPH1 2.0 onPTeeJet VisiFlo color coding only: For other tips see manualRegulating Mode - Speed15PSIprsdbhighTeeJet VisiFlo color coding only: For other tips see manualRegulating Mode - PressureP98-05051 48R1


854 Sprayer ControlMEMORY RELOAD FUNCTIONThe memory reload function is used to restore all programming values topreviously set values. A sprayer manufacturer can pre-program this console forspecific parameters on a sprayer and save those values internally. This stepallows the return to those pre-programmed values if necessary." Use the + or keys to select eitherYES or NO." The default NO means that yourprogramming values are saved asentered." The YES selection changes theprogram values to those programmedand saved by the manufacturer.M e mREN oL o a dPTeeJet VisiFlo color coding only: For other tips see manualWARNING!!IT IS RECOMMENDED THAT YOU LEAVETHIS SETTING ATUNLESS OTHERWISE INSTRUCTEDNO" Press thePRO key to advance to the next step." This should return to the beginning of the program mode." Press and hold thePRO key for three seconds to exit the program mode andsave the programming information to the computer’s memory.For protection, the 854 console does not automatically power down while in theProgram Mode. Exit properly as described above to enable the console’s autopower down feature.Cutting the power to the controller while in the Program Mode does not saveany changes in the computers memory.49 98-05051R1


854 Sprayer ControlApplication Preset Setup ModeTo access the Application Preset SetupMode (Master switch must be OFF)PRESET" Press the key to display the currentpreset being usedPRESET" Pressing the key again within 3seconds will advance to the next preset.This process can be continued throughall 5 presets" To program a particular preset, pressthe P RO key while that preset is displayedP s t- 2 -1 5.0GPAPTeeJet VisiFlo color coding only: For other tips see manualExample:PRESETTo program preset #2, press thekey until PST – 2 – is displayed. Thenpress thePRO key.TIP SPACINGEnter the spacing between the spraynozzles in Inches (cm)" Use the + or keys to adjust thevalue." Press thePRO key to advance to thenext step2 0- 2 -TeeJet VisiFlo color coding only: For other tips see manualP98-05051 50R1


854 Sprayer Control# OF TIPS PER BOOM SECTIONEnter the number of tips on the boomsection corresponding to boom switch#1." Use the + or keys to adjust value." Press thePRO key to advance to thenext stepThe number of tips programmed here arespecific to the preset being used. (I.e.preset – 2 – in this example)S e c61 - 2 -PTeeJet VisiFlo color coding only: For other tips see manual! After programming the number of tips on boom section 1, pressingPROadvances to section 2.! Continue programming the number of tips for each boom section until all 5possible boom sections are programmed.! If a particular boom section switch is not used, set the value to 0.DENSITYAlternate Density UsedWill a product carrier other than water beused?" Use the + or keys to select YES orNO" Press thePRO key to advance to thenext stepDensity ValueIf this carrier has a density other thanwater (i.e. liquid fertilizers) enter theDensity value here" Use the + or keys to change thevalue." Press thePRO key to advance to thenext stepDD e n sPTeeJet VisiFlo color coding only: For other tips see manualDN o1.2 8D e n sPTeeJet VisiFlo color coding only: For other tips see manual51 98-05051R1


854 Sprayer ControlTIP SELECTIONSelect the appropriate color of the spray tip being used." Use the + or keys to move theflashing arrow to the correspondingcolor tab." Press thePRO key to select the color taband advance to the next step! The arrow should be over the color tabmatching the color of the tips beingused (must be ISO color coded tips).! The flow rate of the tip in GPM (LPM)at 40 PSI (2 bar) is displayed in thelower right corner of the display.4 0PSI2 0.0GPAMPH6.0 0.4 0TeeJet VisiFlo color coding only: For other tips see manualPTARGET APPLICATION RATEAfter you have selected the tip being used, the Target Application rate displayshould be flashing. If it is not, press thePRO key 3 or 4 times until the TargetApplication display is flashing." Use the + and keys to adjust thetarget rate." Press thePRO key to accept the valueand advance to the next step.4 0PSI2 0.0GPAMPH6.0 0.4 0PTeeJet VisiFlo color coding only: For other tips see manual98-05051 52R1


854 Sprayer ControlCALCULATION STEPSKnown Pressure CalculationIf the approximate operating pressure is known:" Use the + and keys to adjust thisvalue.! The 854 immediately determines whatthe operating speed must be to achievethe target application rate at thispressure.! If the speed indicated is too high, a set ofsmaller nozzles is needed.! If the speed indicated is too low, a set oflarger nozzles is needed." Press thePRO key to advance to the speedcalculation step.4 0PSI2 0.0GPAMPH6.0 0.4 0PTeeJet VisiFlo color coding only: For other tips see manualKnown Speed Calculation" Use the + or keys to adjust theindicated speed to the intended speed.! The 854 immediately calculates what thepressure must be to maintain the targetapplication rate at this speed.! If the pressure is too high, a set of largernozzles or a slower speed is necessary.! If the pressure is too low, a set of smallernozzles or a faster speed is necessary." Pressing thePRO key again returns to theTip Selection Step.4 0PSI2 0.0GPAMPH6.0 0.4 0PTeeJet VisiFlo color coding only: For other tips see manualContinue to try different speed, pressure, and tip combinations until the desiredcombination is found:" Exit the Application Preset Mode by pressing and holding thePRO key for 2seconds.In the Application Preset Mode the tip colortab must match the actual tips being used.53 98-05051R1


854 Sprayer ControlOperating InstructionsSPRAYER CHECKOUTBefore spraying, check all connections related to the Sprayer Control System.Particular attention should be given to the sensors to ensure the consolereceives good uninterrupted signals. Make sure connections are made and thesensors are properly secured.Very Important: When working around a sprayer or chemicals, always wearprotective clothing and eyewear.Partially fill the sprayer tank with water to flush the system, and to make a visualcheck of the spray tips to make sure all tips are delivering a good spray pattern.Follow these steps, in sequence. The Master Boom Switch must be in the “OFF”position:♦ Make sure the tank shut-off valve is open.♦ Start the engine, engage pump, and set the rpm to that being used whenspraying.♦ Turn the computer on by pressing thePRO key.♦ Ensure that the preset reference flow arrow matches the set of tips you areusing. This can usually be ensured if the tip color matches the color tab onthe console display.♦ Verify that the console recognizesthe simulated speed. If the simulatedspeed has been disabled, due tomovement of the sprayer, simplyactivate the simulated speed by firstturning the Master boom switch onthen pressing thePRO and keyssimultaneously for low simulatedspeed or pressing thePRO and + keysfor high simulated speed.♦ Turn “ON” the toggle switches foreach of the spray boom sections onyour sprayer.40.0PSI2 0.0MPH6.0 7 6GPAVolPTeeJet VisiFlo color coding only: For other tips see manual98-05051 54R1


854 Sprayer Control♦ Press theAuto/Man key so that the red LED light indicates “MAN” mode.♦ Now, toggle the Master boom switch to “ON”.♦ Adjust the pressure with the + and keys. The pressure should increasewhen the + key is pressed and decrease when the key is pressed.At this point, the sprayer is activated and spray tip performance can be visuallychecked.♦ Press the Auto/Man key so that the red LED light indicates “Auto” mode.The control console should regulate to the target application rate for thesimulated speed indicated.♦ Press thePRO and + keys simultaneously (while spraying) to switch theconsole to “high” simulated speed. The control console should increase thepressure and regulate to the target application rate for the new simulatedspeed.♦ Press thePRO and keys simultaneously (while spraying) to switch theconsole to “low” simulated speed. The control console should decrease thepressure and regulate to the target application rate for the new simulatedspeed.To stop spraying, toggle the Master boom switch to “OFF”.The above steps provide a quick way to check out the sprayer and computerizedcontrol system.However, it is recommended that the entire sprayer be calibrated to preparethe machine for operation and to diagnose spray tip wear. Worn tips cancontribute to costly chemical waste and inaccurate spraying, regardless ofthe use of a sprayer control. Calibration is necessary to obtain the benefitsassociated with a computerized sprayer control.55 98-05051R1


854 Sprayer ControlTHE SPRAYING OPERATIONThe sprayer tank is filled and the solution thoroughly mixed. The application rateis determined, as well as the nozzles being using. The sprayer data isprogrammed into the computer.♦ Turn the control console on by pressing thePRO key.♦ Toggle the individual boom switches to the “ON” position, for each of thebooms on your sprayer.♦ TheAuto/Man key should be switched to “AUTO”.♦ In the Auto mode, when the Master boom switch is “OFF”, the targetapplication rate, as well as the target symbol, is displayed in the consoledisplay. When the Master boom switch is “ON”, the actual rate is displayedand the target symbol no longer appears.♦ While spraying with the Master boom switch “ON”, the display alwaysindicates the actual application rate, vehicle speed, application areacovered/total volume applied, and pressure (only if a pressure transducer hasbeen installed).♦ When the point is reached where spraying is to begin, turn the Master boomswitch to the “ON” position. This activates the spraying operation. Maintainthe usual vehicle speed for spraying. Moderate changes in vehicle speed donot affect the application rate, because such changes are compensated for byautomatic pressure increases or decreases by the controller.If for any reason it is necessary to stop, turn the Master boom switch to “OFF”.Alarm warnings can occur momentarily while the pressure regulating valve issearching for a new setting (i.e. after the close of a boom section or other changein normal operation). However, if the alarm stays on for a longer time, the valvemay have reached its limit and the system is unable to regulate flow beyond thelimit.98-05051 56R1


854 Sprayer ControlFeaturesAREA/VOLUME DISPLAYThe 854 Sprayer Control counts application area and measures the total volumeapplied, while the master boom switch is in the “ON” position.! The area counter measures treatedacres and is dependent on the valuesprogrammed for the # of tips perboom section and the tip spacing.! The volume measure is dependent onflow meter pulses, if a flow meter ispresent, or is calculated based onpressure signals from the PressureTransducer.Depending on how the console wasprogrammed in the OEM setup mode, thelower right of the display window shows:! Volume Sprayed! Area Covered! Both (alternating every 3 seconds).To clear the area counter/volumemeasure:3 3PSI2 0.0GPAMPH0.0 5 6.2 5 AcTeeJet VisiFlo color coding only: For other tips see manualC l rF l dY e sC n t rP" Press and hold the Auto/Man key forthree seconds (Master Boom Switchmust be off)." The controller asks if the field counter should be cleared." Use the + or keys to select either YES or NO." Push thePRO key to accept and return to the normal operating mode.PTeeJet VisiFlo color coding only: For other tips see manualNote: The area/volume measure can only be cleared from the normaloperating mode with the Master Boom Switch turned OFF.*****WARNING***********WARNING***********WARNING*****Clearing the area/volume counter in this manner does NOT save this information.If you wish to save this information refer to the Memory Feature in this manual.57 98-05051R1


854 Sprayer ControlMEMORY FEATUREThe TeeJet 854 has 9 individual memory locations as well, as a Total Memorylocation. These memory locations store the volume and area accumulated sincethe last clearing of that display or since the last memory save function.Viewing Memory informationTo view information stored in the memorylocations:" Press the MEM key." Continue to press the MEM key to scrollthrough the different memory locationsClearing Memory LocationsTo clear an existing value from a memorylocation:M e m1 - 91 0 8 0 VolPTeeJet VisiFlo color coding only: For other tips see manual" Press the MEM key." Continue to press the MEM key to scrollto the desired memory location." Press and hold the key for 3seconds.M e m3! The area/volume and volume readingsare reset to zero.! To clear the Total Memory Location,follow the same procedure.0.0 ACTeeJet VisiFlo color coding only: For other tips see manualP*****WARNING***********WARNING***********WARNING*****Clearing the Total Memory Location also clearsALL individual memory locations as well98-05051 58R1


Saving Information To Memory854 Sprayer ControlTo save information to the memory locations:" Press the MEM key." Continue to press the MEM key to scroll tothe desired memory location." Press the + key to save theinformation.! The console automatically exits theMemory Feature and returns to thenormal operating mode.! Any information saved to the individualmemory locations are added to theTotal Memory as well.M e mT o t2 6 4 5 VolPTeeJet VisiFlo color coding only: For other tips see manual*****WARNING***********WARNING***********WARNING*****Saving information to a Memory Location that has an existing value results in theSUM of the existing value and the new value being stored in the memorylocation.ExampleYou have accumulated 50 Ac (Ha) and 1000 Gal (Lit) on consoleMemory Location 1 has 100 Ac (Ha) and 2000 Gal (Lit) previously savedIf the new information is saved to Memory Location 1, the values will be added50 Ac (Ha) + 100Ac (Ha) = 150 Ac (Ha)1000 Gal (Lit) + 2000 Gal (Lit) = 3000 Gal (Lit)Memory Location New Value = 150 Ac (Ha) and 3000 Gal (Lit)Exiting the Memory LocationsTo exit the Memory Feature if no changes were made or after clearing a value:Press and hold the MEMkey for 3 secondsThe console exits the Memory Feature to the normal operating mode.59 98-05051R1


854 Sprayer ControlTANK FEATUREAuto Tank FillingAuto Tank Filling Featurecan only be used ifFill Valvewas selected in theDigital Out #2step of theOEM PROGRAMMINGF I l1 0 0 0 Vol" Master boom switch must be turnedOFF." Press the TANK key." Use the + or key to enter the volumeto be added to the tank." Or, press the key to set the volume tothe maximum tank content." Press thePRO key to activate theprocedure." Turn the Master Boom Switch ON toactivate the Fill Valve (switch)PTeeJet VisiFlo color coding only: For other tips see manualF I lO F F1 0 0 0 VolTeeJet VisiFlo color coding only: For other tips see manualP! The tank then begins filling and theconsole measures the volume.! If it is necessary to stop the fillingprocess for any reason simply turn theMaster Boom Switch OFF. Tank fillingcan be started and stopped at anytime.! When the console has reached thevolume to be filled it automaticallyshuts the valve (switch) off.F I lO nPTeeJet VisiFlo color coding only: For other tips see manual" When the process is complete, turnthe Master Boom Switch OFF" Press and hold the TANK key for 3 seconds to return to the normal operatingmode." Resume spraying.1 0 0 0 Vol98-05051 60R1


Tank Volume Feature854 Sprayer ControlThe console counts down the volume remaining in the tank and alerts theoperator when the Lo Tank level has been reached. The Lo Tank level can beprogrammed by the operator in the System Setup Mode.Viewing Remaining Tank Volume" While spraying in the normal operatingmode, with the Master Boom Switchand individual boom switches ON,press and hold the TANKkey." The lower right display shows thevolume remaining in the tank.3 2PSIMPH6.5 3 4 8When the volume reaches the preprogrammedlevel:! The audible alarm activates! The display switches to the TankVolume display.! The operator must acknowledge the low tank level by pressing the TANK orPROkey. This returns the console to the normal operating view.Resetting the Tank VolumeTo reset the tank volume:Audible Alarm(Long beep – Low Priority)Activates with this featureif enabledVolTeeJet VisiFlo color coding only: For other tips see manualP" Press the TANK key." Use the + or key to enter apartial tank volume." Press the key to reset the tankvolume counter to the maximumvalue of the tank volume." Press the TANK orPRO key to return tothe normal operating view.1 0 0 0 VolPTeeJet VisiFlo color coding only: For other tips see manual61 98-05051R1


854 Sprayer ControlAPPLICATION ALARMIf the 854 senses a continuousdiscrepancy of 10% or more between theTarget Application Rate and the ActualApplication Rate:! The application rate window flashesThis alerts the operator to a problem withthe sprayer plumbing, operation, orprogramming.4 9PSI1 7.4MPH7.0 5 3 0GPAVolPTeeJet VisiFlo color coding only: For other tips see manualAudible Alarm(3 short beeps – High Priority)Activates with this featureif enabledSENSOR LED ALARMSThe 854 has sensor LED’s across the top of the display. These LED’s help alertthe operator to problems with the sprayer, sprayer control system, or application.Speed Sensor LED Alarm – LED displays a red light if the console losesspeed signals.Flow Sensor LED Alarm – LED displays a red light if the console losesflow signals.Pressure Sensor LED Alarm – LED displays a red light if the consoleloses pressure signals.!General LED Alarm – This LED alarm is used for discrepancies betweenthe flow meter and pressure transducer if both are installed andprogrammed.98-05051 62R1


854 Sprayer ControlNO SPEED ALARMIf the 854 stops receiving pulses from thespeed sensor:! The speed display window flashes! The Speed Sensor LED Alarm isdisplayed! The Tractor Speed symbol flashes atthe top of the display4 5PSIo.oMPHo.o 6 4 2GPAVolAudible Alarm(Steady beep – Medium Priority)Activates with this featureif enabledThis alarm occurs only when theMaster boom switch is “ON”.PTeeJet VisiFlo color coding only: For other tips see manual!Red LEDNO FLOW ALARMIf the 854 stops receiving pulses from theflow meter! The turbine symbol flashes at the topof the display.! The Flow Sensor LED Alarm isdisplayedThis alarm indicates that the flow meterhas stalled and alerts the operator thatthere is a problem with the flow meter orelsewhere in the system.PSI00.0GPAMPH4.8 3 2.5 0 AcPTeeJet VisiFlo color coding only: For other tips see manualAudible Alarm(Steady beep – Medium Priority)Activates with this featureif enabledThis alarm occurs only when theMaster boom switch is “ON”.Red LED!63 98-05051R1


854 Sprayer ControlNO PRESSURE ALARM (only active if Pressure Transducer Installed isselected in System Setup)If the 854 stops receiving a pressuresignal! The Pressure display windowflashes! The Pressure Sensor LED Alarm isdisplayedThis alarm indicates that the pressuretransducer has failed or lost itsconnection and alerts the operator thatthere is a problem with the pressuretransducer or elsewhere in the system.PSI02 0.0GPAMPH9.0 7 4 0VolPTeeJet VisiFlo color coding only: For other tips see manualAudible Alarm(Steady beep – Medium Priority)Activates with this featureif enabledThis alarm occurs only when theMaster boom switch is “ON”.Red LED!FLOW/PRESSURE DISCREPANCY ALARMThis alarm activates if there is adiscrepancy between the flow meter andpressure transducer. The amount ofdiscrepancy allowed is defined by theCalibrate Tip Level % step in the OEMsetup mode.! The Pressure Display Window flashes.! The Application Rate Window flashes.! The General Alarm LED is displayedAudible Alarm(Steady beep – Medium Priority)Activates with this featureif enabled3 0PSI2 0.0GPAMPH1 2. 5 7. 3 5 AcTeeJet VisiFlo color coding only: For other tips see manual!Red LEDP98-05051 64R1


854 Sprayer ControlBOOST MODEThe 854 is capable of boosting the target application rate either up or down in10% increments.Boost UpTo activate the boost up mode:" Press the + key." Each subsequent pressing of the +key boosts the target rate up 10%.U p2 4.0GPA! The amount boosted up is recordedon the display temporarily (approx. 2seconds).! The target symbol flashes, anytimethe system is in the boost mode, toalert the operator of the “off target”condition.2 0 3 9.5 0 AcPTeeJet VisiFlo color coding only: For other tips see manualTo return to the target application rate:" The operator can use the key to get back in 10% increments" The operator can push the + and keys simultaneously to get back to thetarget rate in one step.Boost DownTo activate the boost down mode:" Press the key." Each subsequent pressing of thekey boosts the target rate down 10%.! The amount boosted down isrecorded on the display.! The target symbol flashes, anytimethe system is in the boost mode, toalert the operator of the “off target”conditionD n1 4.03 0 8 7 7GPAVolPTeeJet VisiFlo color coding only: For other tips see manual65 98-05051R1


854 Sprayer ControlTo return to the target application rate:" The operator can either use the + key to get back in 10% increments" The operator can push the + and keys simultaneously to get back to thetarget rate in one step.AUTO POWER DOWNThe 854 console is designed to poweritself off after 10 minutes (or at the timespecified in the Auto Power Down Timein the OEM Setup Mode) of no inputs.This feature keeps the console fromdraining the battery on the sprayer, if theoperator inadvertently leaves theconsole powered on for an extendedperiod. This only occurs when theMaster boom switch is turned OFF andthe console is not receiving inputs fromany of the sensors (the sprayer is inactive).PTeeJet VisiFlo color coding only: For other tips see manualTo manually power the console off, refer to the Powering Console On/Off sectionof this manual.Note: The Auto Power Down feature is disabled any time the console is inany program mode.SMART SENSINGWith both a pressure and flow sensor installed, the 854 determines when the flowrate has dropped below the capacity of the flow meter being used, andautomatically switches to pressure based regulation. When the flow rate againreaches an acceptable level for the flow meter to regulate, the 854 automaticallyswitches back to flow based regulation.SMART SENSING98-05051 66R1