<strong>Firestone</strong> <strong>FlashGard</strong>Physical Properties ChartPROPERTY TEST METHOD TYPICAL VALUESTensile Strength, min., (MPa) ASTM D-412, Die C 1305 (9)Elongation, min., % ASTM D-412, Die C 300Tear Res<strong>is</strong>tance, Ibf/in (kN/m) ASTM D-624, Die C 150 (26.3)Ozone Res<strong>is</strong>tance166 hrs./100 pphm @ 104˚ Fwith 50% extension ASTM D-1149 No CracksHeat aging, 28 days @ 240˚ F ASTM D-573Tensile Strength, min.,psi (MPa) ASTM D-412 1205 (8.3)Elongation, min., % ASTM D-412 200Brittleness Point, max. ˚F (˚C) ASTM D-2137 -49˚ (-45˚) passWater Absorption, changein weight after immersion inwater for 166 hrs. @ 158˚ F, % ASTM D-471 +8, -2Water Vapor Permeability,Perm-Mils ASTM E-96 2.0<strong>Firestone</strong> <strong>FlashGard</strong>Standard SizesThickness Width Length Rolls per box40 mil (1.02 mm) 12" (300 mm) 50'(15.25 m) 2 rolls40 mil (1.02 mm) 16" (400 mm) 50'(15.25 m) 1 roll40 mil (1.02 mm) 18" (450 mm) 50'(15.25 m) 1 roll40 mil (1.02 mm) 20" (500 mm) 50'(15.25 m) 1 roll40 mil (1.02 mm) 24" (600 mm) 50'(15.25 m) 1 roll40 mil (1.02 mm) 36" (900 mm) 50'(15.25 m) 1 rollNote: Th<strong>is</strong> brochure <strong>is</strong> meant only to highlight <strong><strong>Firestone</strong>'s</strong> products and specifications. Information <strong>is</strong> subject to change without notice. All products and specificationsare l<strong>is</strong>ted in approximate weights and measurements. For complete product and detail information, please refer to the appropriate Technical Manual.<strong>Firestone</strong> takes responsibility for furn<strong>is</strong>hing quality materials which meet <strong><strong>Firestone</strong>'s</strong> publ<strong>is</strong>hed product specifications. As neither <strong>Firestone</strong> itself nor itsrepresentatives practice architecture, <strong>Firestone</strong> offers no opinion on, and expressly d<strong>is</strong>claims any responsibility for the soundness of any structure on which itsproducts may be applied. If questions ar<strong>is</strong>e as to the soundness of a structure or its ability to support a planned installation properly, the Owner should obtainopinions of competent structural engineers before proceeding. <strong>Firestone</strong> accepts no liability for any structural failure or for resultant damages, and no <strong>Firestone</strong>Representative <strong>is</strong> authorized to vary th<strong>is</strong> d<strong>is</strong>claimer.<strong>Firestone</strong> Building Products<strong>Specialty</strong> Products Div<strong>is</strong>ion310 E. 96th Street • Indianapol<strong>is</strong>, IN 46240800-428-4442, ext. 57095 • FAX: 317-575-7002 • www.firestonebpco.com©2005 Printed U.S.A. 4/05 Item #5020

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!