<strong>Boilers</strong><strong>Baseboard</strong> <strong>Radiation</strong><strong>Finned</strong> <strong>Tube</strong> (<strong>Commercial</strong>) <strong>Radiation</strong>Indirect-fired Water HeatersUpdated: April 2009


* The manufacturer should be consulted before selecting a boiler for installation on a job having unusual piping and pickup requirements. It is essential thatthe advice of the manufacturer of the boiler be solicited before selecting a boiler for replacement on an existing installation which has a larger amount ofpiping than would normally be installed, or where other unusual conditions exist, such as intermittent operation, temperature conditions other than normal,and unbalanced systems.** Up to 1,254 MBh rating: by 1.333; 1,256 to 1,936 MBh: decreasing factors down to 1.288; Above 1,936 MBh: by 1.288BOILER HEADING ABBREVIATIONSComb Effy (%) = Combustion Efficiency, percent Chim Hgt (ft) = Chimney Height, feetOil (gph) = Oil input, gallons per hourSteam (sqft) = Steam Square Feet, 240 Btuh/Square FeetSteam (MBh) = Steam, thousands of Btu’s per hour Thermal Effy (%) = Thermal Efficiency, percentVent Size (LxWxH) = inches x inches x feetWater (MBh) = Water, thousands of Btu/hourHeat Cap. (MBh) = Heating Capacity, thousands of Btu/hourMINIMUM STACK AREAS FOR OIL-FIRED NATURAL DRAFT RESIDENTIAL BOILERSRECTANGULARROUNDBurner Nominal Burner Inside DiameterCapacity Stack Sizes Capacity of Linernot Over (inches) not Over (inches)2.1 gal/hr 8 x 8 1.3 gal/hr 63.5 gal/hr 8 x 12 1.8 gal/hr 72.5 gal/hr 8Boiler TestingFORCED DRAFT RESIDENTIAL BOILERSD.O.E. HeatingMinimum VentCapacity – MBhDiameter - InchesUp to 132..................................................................... 4133 – 198..................................................................... 5199 – 324..................................................................... 6The widespread prevalence of I=B=R Ratings has virtually eliminated the “credibility’ problem which existed around theturn of the 20 th century, when there were no national standards. Each manufacturer assigned its own Btu output to theirproducts; ethical producers assigned conservative ratings while others exaggerated to help sell boilers. That was the state ofthe market when the predecessor of the Institute of Boiler and Radiator Manufacturers (I=B=R) was founded in 1915.The I=B=R Rating Procedure for Heating <strong>Boilers</strong> has the following basic requirements in order for a model to be certifiedand licensed by <strong>AHRI</strong>. Every boiler must meet ASME standards for construction and for safety devices. Every commercialboiler must meet a minimum steady state efficiency of 75%, although most are much higher. Every residential boiler mustmeet a minimum of 80% AFUE except natural gas steam, which must meet at least 75% AFUE.Steady State efficiency tests for commercial and residential boilers are essentially the same. However, in 1978, the U.S.Department of Energy mandated that residential boilers up to 300,000 Btuh input are to have an additional test for AnnualFuel Utilization Efficiency (AFUE) as a guide for homeowners to ascertain the relative efficiencies of various brands. Theadded test includes a “heat-up” and “cool-down” cycling test which provides an estimate of the annual cost of operation.Besides tests on new models, certification tests are performed on existing models on a planned cycle, annually for residentialboilers, and five years for commercial sizes, as long as that model is being offered on the market. This is truly an allencompassingprogram to ensure that the boiler will provide the amount of heat specified.Unless otherwise noted, the commercial boilers in this book have been tested in accordance with test procedures specified inthe BTS-2000 Testing Standard for <strong>Commercial</strong> Space Heating <strong>Boilers</strong>.© Copyright 2009 Air-Conditioning, Heating, and Refrigeration InstituteAPR 2009 - 4


COMMERCIAL BOILERSBoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)AERCO INTERNATIONAL, INC.ALUMINUMSteam Water(MBh) (MBh)VentSize(LxWxH)#MODULEXModulating, Condensing, Pressure Fired, Inter. Ign., Natural or Propane GasMLX303 303 279 92.0243 4" Dia.MLX454 454 418 92.0363 4" Dia.MLX606 606 558 92.0485 4" Dia.MLX757 757 696 92.0605 6" Dia.MLX909 909 835 92.0726 6" Dia.MLX1060 1060 975 92.0848 6" Dia.Ratings based on 9.0% CO2 and 0" water draft.STAINLESS STEELBenchmark Low NOxPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural GasBMK1.5LN 1500 1379 93.9 91.91199 6" Dia.Ratings based on 9.7% CO2 and +0.001" water draft at the vent.Benchmark Low NOx SeriesModulating, Condensing, Forced Draft, Inter. Ign., Natural GasBMK 2.0 LN 2000 1846 92.3 91.01605 8" Dia.BMK 3.0 LN 3000 2856 95.2 93.92483 8" Dia.CAST IRONBIASI, S.p.A.c/o QHT, INC.B40 SeriesForced Draft, Light OilB40-7 2.50 301 87.8 86.0262B40-8 3.00 365 88.1 86.9317B40-9 3.50 429 88.4 87.6373B40-10 4.00 493 88.6 88.0429B40-11 4.50 557 88.7 88.4484B40-12 5.0 622 88.7 88.8541Ratings based on 13.2% CO2 and -0.02" water draft at the vent.SG SeriesForced Draft, Light OilSG-7 2.25 272 86.6 86.2237Ratings based on 13.0% CO2 and -0.02" water draft at the vent.BUDERUS-BOSCH THERMOTECHNOLOGYCORPALUMINUMGB162Power Burner, Modulating, Condensing, Pressure Fired, Inter. Ign., Natural GasGB162-100 333 298 89.2 89.4259 6" Dia.Ratings based on 9.3% CO2 and 0" water draft.Power Burner, Modulating, Condensing, Pressure Fired, Inter. Ign., Propane GasGB162-100 315 282 89.2 89.4245 6" Dia.Ratings based on 9.3% CO2 and 0" water draft.GB312Modulating, Condensing, Induced Draft, Inter. Ign., Natural GasGB312 - 90 328 305 93.4 93.1265 5" Dia.GB312 - 120 441 409 93.1 92.8356 6" Dia.GB312 - 160 588 544 92.8 92.5473 6" Dia.GB312 - 200 733 676 92.5 92.3588 8" Dia.GB312 - 240 881 810 92.2 92.0704 8" Dia.GB312 - 280 1029 944 92.0 91.7821 8" Dia.CAST IRONG215 SeriesNatural Draft, Light OilNameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)G215-7 2.50 294 86.7 83.9256 8x12x15Ratings based on 13.0% CO2 and -0.005" water draft.G315 SeriesNatural Draft, Light OilG315-5 3.00 350 86.8 83.3304 8x12x15G315-6 3.85 454 86.9 84.3395 12x12x15G315-7 4.7 559 87.0 84.9486 12x12x15G315-8 5.6 663 87.1 85.4577 12x16x15G315-9 6.4 768 87.1 85.7668 12x16x15Ratings based on 13.0% CO2 and -0.02" water draft.Power Burner, Natural Draft, Inter. Ign., Natural GasG315-5 433 350 84.2 80.8304 8x12x15G315-6 556 454 84.3 81.8395 12x12x15G315-7 678 559 84.4 82.4486 12x12x15G315-8 801 663 84.4 82.8577 12x16x15G315-9 924 768 84.5 83.1668 12x16x15Ratings based on 10.0% CO2 and -0.02" water draft.#G334X SeriesAtmospheric, Inter. Ign., Natural or Propane GasG334X-73 301 249 82.7217G334X-92 378 314 83.1273G334X-116 476 396 83.2344G334X-132 542 451 83.2392G515 SeriesNatural Draft, Light OilG515-7 6.9 818 88.2 84.8711 12x16x15G515-8 8.4 1009 88.2 85.5877 16x16x15G515-9 10.0 1201 88.1 86.11044 16x16x15G515-10 11.6 1392 88.1 86.41210 16x20x15G515-11 13.0 1583 88.1 86.81377 16x20x15G515-12 14.6 1775 88.1 87.01543 16x20x15Ratings based on 13.0% CO2 and -0.02" water draft.Power Burner, Natural Draft, Inter. Ign., Natural GasG515-7 995 818 85.6 82.2711 12x16x15G515-8 1216 1009 85.5 83.0877 16x16x15G515-9 1438 1201 85.5 83.51044 16x16x15G515-10 1660 1392 85.5 83.91210 16x20x15G515-11 1881 1583 85.4 84.21377 16x20x15G515-12 2103 1775 85.4 84.41543 16x20x15Ratings based on 10.0% CO2.G615 SeriesForced Draft, Light OilG615-9 16.0 1951 86.7 87.11697 14" Dia.G615-10 18.5 2242 86.7 86.51950 14" Dia.G615-11 21.0 2532 86.6 86.12202 14" Dia.G615-12 23.5 2822 86.6 85.82454 16" Dia.G615-13 26.0 3112 86.5 85.52706 16" Dia.G615-14 28.5 3402 86.5 85.32958 18" Dia.G615-15 31.0 3692 86.5 85.13210 18" Dia.G615-16 33.5 3982 86.5 84.93463 18" Dia.Ratings based on 13.0% CO2 and +0.10" water draft at the vent.Power Burner, Forced Draft, Inter. Ign., Natural GasG615-9 2309 1951 84.1 84.51697 14" Dia.G615-10 2670 2242 84.1 83.91950 14" Dia.G615-11 3031 2532 84.0 83.52202 14" Dia.G615-12 3392 2822 84.0 83.22454 16" Dia.G615-13 3753 3112 83.9 82.92706 16" Dia.G615-14 4113 3402 83.9 82.72958 18" Dia.G615-15 4474 3692 83.9 82.53210 18" Dia.G615-16 4835 3982 83.9 82.43463 18" Dia.Ratings based on 10.0% CO2 and +0.10" water draft at the vent.STEELSB315 SeriesPower Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane GasAPR 2009 - 36# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)BUDERUS-BOSCH THERMOTECHNOLOGYCORPSTEELVentSize(LxWxH)SB315 SeriesPower Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane GasSB-315-90 313 302 96.6 96.4263SB-315-115 399 385 96.6 96.4335SB615 SeriesPower Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane GasSB-615-145 506 484 97.1 95.6421SB-615-185 644 612 96.7 95.0532SB-615-240 835 791 96.5 94.8688SB-615-310 1080 1022 96.4 94.6889SB-615-400 1393 1317 96.3 94.51145SB-615-510 1776 1678 96.2 94.51459SB-615-640 2228 2104 96.2 94.41830SB735 SeriesPower Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane GasSB-735-790 2751 2611 94.8 96.92270SB-735-970 3378 3257 95.6 96.12832SB-735-1200 4179 4082 96.5 97.53550BURNHAM COMMERCIALCAST IRON#8H SERIESAtmospheric, Inter. Ign., Natural or Propane Gas806H 315 262 83.1 80.2228807H 374 311 83.2 80.0270808H 433 360 83.3 79.9313809H 491 409 83.4 79.8356810H 550 459 83.4 79.7399MPCPower Burner, Forced Draft, Inter. Ign., Natural GasMPC-4 500 424 86.3 84.7369 8" Dia.MPC-5 773 652 86.1 84.3567 8" Dia.MPC-6 996 837 86.0 84.1728 10" Dia.MPC-7 1216 1023 86.0 84.1890 10" Dia.MPC-8 1438 1209 85.9 84.11051 10" Dia.MPC-9 1660 1395 85.9 84.01213 12" Dia.MPC-10 1881 1580 85.9 84.01374 12" Dia.MPC-11 2103 1766 85.9 84.01536 12" Dia.MPC-12 2325 1951 85.8 83.91697 14" Dia.MPC-13 2547 2137 85.8 83.91858 14" Dia.MPC-14 2769 2322 85.8 83.92019 14" Dia.MPC-15 2991 2508 85.8 83.82181 14" Dia.MPC-16 3213 2694 85.8 83.82343 14" Dia.MPC-17 3435 2880 85.8 83.82504 14" Dia.MPC-18 3657 3065 85.8 83.82665 14" Dia.Ratings based on 10.0% CO2 and +0.10" water draft at the vent.Power Burner, Forced Draft, Light OilMPC-4 3.55 424 89.0 87.3369 8" Dia.MPC-5 5.5 652 88.8 86.9567 8" Dia.MPC-6 7.1 837 88.7 86.8728 10" Dia.MPC-7 8.7 1023 88.7 86.7890 10" Dia.MPC-8 10.2 1209 88.6 86.71051 10" Dia.MPC-9 11.8 1395 88.6 86.61213 12" Dia.MPC-10 13.4 1580 88.6 86.61374 12" Dia.MPC-11 15.0 1766 88.5 86.61536 12" Dia.MPC-12 16.6 1951 88.5 86.51697 14" Dia.MPC-13 18.2 2137 88.5 86.51858 14" Dia.MPC-14 19.8 2322 88.5 86.52019 14" Dia.MPC-15 21.4 2508 88.4 86.52181 14" Dia.MPC-16 23.0 2694 88.4 86.42343 14" Dia.NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)MPC-17 24.6 2880 88.4 86.42504 14" Dia.MPC-18 26.2 3065 88.4 86.42665 14" Dia.Ratings based on 13.2% CO2 and +0.10" water draft at the vent.#Series 5Atmospheric, Inter. Ign., Propane GasK5006 376 301 80.0 77.0 942 226 262K5007 439 351 80.0 77.0 1096 263 305K5008 512 410 80.0 77.0 1279 307 356K5009 585 468 80.0 77.0 1463 351 407K5010 658 527 80.0 77.0 1646 395 458K5011 731 585 80.0 77.0 1829 439 509K5012 804 644 80.0 77.0 2013 483 560K5013 878 702 80.0 77.0 2196 527 610K5014 951 761 80.0 77.0 2379 571 661K5015 1024 819 80.0 77.0 2558 614 712K5016 1097 878 80.0 77.0 2742 658 763K5017 1170 936 80.0 77.0 2925 702 814K5018 1243 995 80.0 77.0 3108 746 865K5019 1316 1053 80.0 77.0 3292 790 916K5020 1389 1112 80.0 77.0 3475 834 967K5021 1463 1170 80.0 77.0 3658 878 1017K5022 1536 1229 80.0 77.0 3842 922 1068K5024 1682 1346 80.0 77.0 4233 1016 1170K5026 1828 1463 80.0 77.0 4642 1114 1272Atmospheric, Standing Pilot, Natural GasK5006 401 321 80.0 77.0 1004 241 279K5007 468 375 80.0 77.0 1171 281 326K5008 546 437 80.0 77.0 1367 328 380K5009 624 500 80.0 77.0 1558 374 434K5010 702 562 80.0 77.0 1754 421 488K5011 780 624 80.0 77.0 1950 468 543K5012 858 687 80.0 77.0 2146 515 597K5013 936 749 80.0 77.0 2342 562 651K5014 1014 812 80.0 77.0 2538 609 705K5015 1092 874 80.0 77.0 2729 655 760K5016 1170 936 80.0 77.0 2925 702 814K5017 1248 999 80.0 77.0 3121 749 868K5018 1326 1061 80.0 77.0 3317 796 922K5019 1404 1124 80.0 77.0 3513 843 977K5020 1482 1186 80.0 77.0 3704 889 1031K5021 1560 1248 80.0 77.0 3900 936 1085K5022 1638 1311 80.0 77.0 4113 987 1139K5024 1794 1436 80.0 77.0 4546 1091 1248K5026 1950 1560 80.0 77.0 4975 1194 1357V11 SeriesPower Burner, Forced Draft, Inter. Ign., Natural GasV1104 837 667 82.8 79.7 2083 500 580 8" Dia.V1105 1068 857 82.6 80.2 2679 643 745 8" Dia.V1106 1328 1069 82.5 80.4 3342 802 930 8" Dia.V1107 1588 1281 82.4 80.7 4013 963 1114 10" Dia.V1108 1876 1517 82.3 80.8 4829 1159 1319 10" Dia.V1109 2136 1729 82.3 80.9 5563 1335 1503 10" Dia.V1110 2396 1941 82.2 81.0 6279 1507 1688 12" Dia.V1111 2656 2154 82.2 81.1 6967 1672 1873 12" Dia.V1112 2887 2334 82.1 80.9 7550 1812 2030 12" Dia.V1113 3103 2503 82.0 80.7 8096 1943 2177 12" Dia.V1114 3392 2730 81.9 80.4 8833 2120 2374 14" Dia.V1115 3680 2957 81.8 80.3 9567 2296 2571 14" Dia.V1116 3897 3129 81.7 80.2 10113 2427 2718 14" Dia.V1117 4186 3353 81.7 80.1 10846 2603 2916 14" Dia.V1118 4474 3580 81.6 80.0 11583 2780 3113 16" Dia.V1119 4691 3739 81.4 79.7 12096 2903 3251 16" Dia.V1120 4979 3957 81.2 79.5 12800 3072 3441 16" Dia.V1121 5268 4174 81.0 79.2 13504 3241 3630 16" Dia.V1122 5485 4334 80.8 79.1 14021 3365 3769 18" Dia.V1123 5733 4551 80.7 78.8 14721 3533 3957 18" Dia.Ratings based on 10.0% CO2 and +0.10" water draft at the vent.APR 2009 - 37# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)V88W 2.35 275 84.2 81.4239 8x12x15BURNHAM COMMERCIALV89S 2.60 298 84.1 82.3 933 224 8x12x15CAST IRONV89W 2.60 299 84.1 82.3260 8x12x15V11 SeriesRatings based on 13.0% CO2 and -0.02" water draft.Power Burner, Forced Draft, Light Oil STAINLESS STEELV1104 5.8 667 85.3 82.2 2083 500 580 8" Dia. AlpineV1105 7.4 857 85.1 82.7 2679 643 745 8" Dia. Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural orV1106 9.2 1069 85.0 83.0 3342 802 930 8" Dia.Propane GasV1107 11.0 1281 84.9 83.2 4013 963 1114 10" Dia. ALP399 399 376 94.5 94.1327 4" Dia.V1108 13.0 1517 84.9 83.3 4829 1159 1319 10" Dia. Ratings based on 9.0% CO2 and +0.01" water draft at the vent.V1109 14.8 1729 84.8 83.4 5563 1335 1503 10" Dia.V1110 16.6 1941 84.8 83.5 6279 1507 1688 12" Dia. STEELV1111 18.4 2154 84.8 83.6 6967 1672 1873 12" Dia. Opus O1V1112 20.0 2334 84.6 83.4 7550 1812 2030 12" Dia.Power Burner, Natural Draft, Light OilV1113 21.5 2503 84.5 83.1 8096 1943 2177 12" Dia. O1-3-225 2.25 267 86.5 84.9232 8x12x15V1114 23.5 2730 84.4 83.0 8833 2120 2374 14" Dia. Ratings based on 13.5% CO2.V1115 25.5 2957 84.3 82.8 9567 2296 2571 14" Dia.V1116 27.0 3129 84.3 82.7 10113 2427 2718 14" Dia. RSA SeriesV1117 29.0 3353 84.2 82.6 10846 2603 2916 14" Dia.Power Burner, Natural Draft, Light OilV1118 31.0 3580 84.1 82.5 11583 2780 3113 16" Dia. RSA240 2.40 268 84.2 79.3233 8x12x20V1119 32.5 3739 83.9 82.2 12096 2903 3251 16" Dia. RSA285 2.85 318 83.2 79.2277 8x12x20V1120 34.5 3957 83.7 81.9 12800 3072 3441 16" Dia. Ratings based on 12.5% CO2 and -0.02" water draft.V1121 36.5 4174 83.5 81.7 13504 3241 3630 16" Dia.V1122 38.0 4334 83.3 81.5 14021 3365 3769 18" Dia.COLUMBIA BOILER COMPANY OF POTTSTOWNV1123 40.0 4551 83.2 81.3 14721 3533 3957 18" Dia.Ratings based on 13.0% CO2 and +0.10" water draft at the vent.STEELV9A SeriesWB Five Star SeriesPower Burner, Forced Draft, Inter. Ign., Natural GasForced Draft, Light OilV903 447 358 82.5 80.0 1121 269 311 7" Dia. WB-225 2.25 264 85.6 83.7230V904 606 485 82.5 80.1 1517 364 422 7" Dia. WB-250 2.50 291 85.2 83.4253V905 808 647 82.4 80.1 2021 485 563 8" Dia. WB-275 2.75 319 84.9 82.9277V906 1010 809 82.4 80.1 2529 607 703 8" Dia. Ratings based on 13.2% CO2 and -0.02" water draft at the vent.V907 1198 960 82.3 80.1 3000 720 835 8" Dia.V908 1386 1112 82.3 80.2 3475 834 967 10" Dia.CROWN BOILER CO.V909 1674 1343 82.6 80.2 4225 1014 1168 10" Dia.V910 1905 1528 82.2 80.2 4867 1168 1329 10" Dia. CAST IRONV911 2136 1714 82.1 80.3 5513 1323 1490 12" Dia. #32 SeriesV912 2367 1900 82.1 80.3 6142 1474 1652 12" Dia.Atmospheric, Inter. Ign., Natural or Propane GasRatings based on 9.7% CO2 and +0.10" water draft at the vent.32-475*N 475 380 80.5 75.4 1188 285 330Power Burner, Forced Draft, Light Oil 32-570*N 570 456 80.5 75.4 1425 342 397V903 3.10 347 85.2 80.0 1083 260 302 7" Dia. 32-665*N 665 532 80.5 75.4 1663 399 463V904 4.20 483 86.0 82.1 1508 362 420 7" Dia. 32-760*N 760 608 80.5 75.4 1900 456 529V905 5.6 646 85.5 82.4 2021 485 562 8" Dia. 32-855*N 855 684 80.5 75.4 2138 513 595V906 7.0 808 85.2 82.5 2525 606 703 8" Dia. 32-950*N 950 760 80.5 75.4 2375 570 661V907 8.3 959 85.1 82.6 2996 719 834 8" Dia. 32-1045*N 1045 836 80.5 75.4 2613 627 727V908 9.6 1110 84.9 82.6 3471 833 965 10" Dia. 32-1140*N 1140 912 80.5 75.4 2850 684 793V909 11.6 1342 84.8 82.7 4225 1014 1167 10" Dia. 32-1235*N 1235 988 80.5 75.4 3088 741 859V910 13.2 1528 84.8 82.7 4867 1168 1329 10" Dia. 32-1330*N 1330 1064 80.5 75.4 3325 798 925V911 14.8 1714 84.7 82.7 5513 1323 1490 12" Dia. 32-1425*N 1425 1140 80.5 75.4 3563 855 991V912 16.4 1900 84.7 82.7 6142 1474 1652 12" Dia. 32-1520*N 1520 1216 80.5 75.4 3801 912 1057Ratings based on 12.5% CO2 and +0.10" water draft at the vent.32-1615*N32-1710*N161517101292136880.580.575.475.440504313972103511231190BURNHAM HYDRONICS (U.S. BOILER CO., INC.)32-1805*N 1805 1444 80.5 75.4 4575 1098 125632-1900*N 1900 1520 80.5 75.4 4838 1161 1322CAST IRON32-1995*N 1995 1596 80.5 75.4 5104 1225 1388#Independence32-2090*N 2090 1672 80.5 75.4 5367 1288 1454Atmospheric, Standing Pilot, Natural Gas32-2185*N 2185 1748 80.5 75.4 5629 1351 152032-2280*N 2280 1824 80.5 75.4 5892 1414 1586IN10 315 260 82.5 79.5 812 19532-2375*N 2375 1900 80.5 75.4 6142 1474 1652IN10 315 264 83.5 80.522632-2470*N 2470 1976 80.5 75.4 6392 1534 1718IN11 349 288 82.5 79.5 900 21632-2565*N 2565 2052 80.5 75.4 6638 1593 1784IN11 349 292 83.5 80.525032-2660*N 2660 2128 80.5 75.4 6883 1652 1850IN12 385 318 82.5 79.5 996 23932-2755*N 2755 2204 80.5 75.4 7129 1711 1917IN12 385 342 83.5 80.527632-2850*N 2850 2280 80.5 75.4 7375 1770 1983V8 Series#Bermuda SeriesPower Burner, Natural Draft, Light OilAtmospheric, Inter. Ign., Natural or Propane GasV88S 2.35 266 84.2 81.4 833 200 8x12x15APR 2009 - 38# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelCAST IRONNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)CROWN BOILER CO.Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)#Bermuda SeriesAtmospheric, Inter. Ign., Natural or Propane GasBSI310E 310 253 81.5 791 190 220BSI345E 345 282 81.6 881 212 245BSI379E 379 309 81.6 966 232 269Atmospheric, Standing Pilot, Natural or Propane GasBSI310S 310 253 81.5 791 190 220BSI345S 345 282 81.6 881 212 245BSI379S 379 309 81.6 966 232 269#Cayman SeriesAtmospheric, Inter. Ign., Natural or Propane GasCWI310E 310 255 82.4222CWI345E 345 284 82.3247CWI379E 379 312 82.2271Atmospheric, Standing Pilot, Natural or Propane GasCWI310S 310 255 82.4222CWI345S 345 284 82.3247CWI379S 379 312 82.2271Natural Gas onlyBoilerModelNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)Power Burner, Forced Draft, Inter. Ign., Natural or Propane Gas24-04 594 476 82.5 80.1 1488 357 414 7" Dia.24-05 792 634 82.4 80.1 1983 476 551 8" Dia.24-06 990 793 82.4 80.1 2479 595 690 8" Dia.24-07 1174 940 82.3 80.1 2938 705 817 8" Dia.24-08 1358 1089 82.3 80.2 3404 817 947 10" Dia.24-09 1641 1316 82.3 80.2 4133 992 1144 10" Dia.24-10 1867 1497 82.2 80.2 4758 1142 1302 10" Dia.24-11 2093 1681 82.1 80.3 5396 1295 1462 12" Dia.24-12 2320 1863 82.1 80.3 6017 1444 1617 12" Dia.Ratings based on 9.7% CO2 and +0.10" water draft at the vent.Power Burner, Forced Draft, Light Oil24-03 3.05 342 85.2 80.0 1071 257 297 7" Dia.24-04 4.10 471 86.0 82.1 1471 353 410 7" Dia.24-05 5.5 634 85.5 82.4 1983 476 551 8" Dia.24-06 6.9 797 85.2 82.5 2492 598 693 8" Dia.24-07 8.1 937 85.1 82.6 2929 703 815 8" Dia.24-08 9.4 1087 84.9 82.6 3396 815 945 10" Dia.24-09 11.4 1316 84.8 82.7 4146 995 1148 10" Dia.24-10 13.0 1505 84.8 82.7 4788 1149 1309 10" Dia.24-11 14.6 1690 84.7 82.7 5429 1303 1470 12" Dia.24-12 16.0 1852 84.7 82.7 5983 1436 1610 12" Dia.Ratings based on 12.5% CO2 and +0.10" water draft at the vent.F SeriesDUNKIRK BOILERS, ECR INTERNATIONAL, INC.Power Burner, Forced Draft, Inter. Ign., Natural GasF4 433 355 82.5 81.7309 7" Dia. CAST IRONF5 577 478 82.5 82.7416 7" Dia. #Series D247F6 722 600 82.4 83.2522 8" Dia.Atmospheric, Inter. Ign., Natural GasF7 866 723 82.4 83.5629 9" Dia.D247-300 300 240 80.0 750 180 209F8 1082 907 82.3 83.8789 10" Dia.D247-400 400 320 80.0 1000 240 278F9 1299 1091 82.2 84.0949 10" Dia.D247-500 500 400 80.0 1250 300 348Ratings based on 9.7% CO2 and +0.10" water draft at the vent.D247-600 600 480 80.0 1500 360 417Power Burner, Forced Draft, Light Oil D247-700 700 560 80.0 1750 420 487F4 3.00 355 85.0 84.5309 7" Dia. D247-800 800 640 80.0 2000 480 557F5 4.00 478 85.0 85.3416 7" Dia. D247-900 900 720 80.0 2250 540 626F6 5.0 600 84.9 85.8522 8" Dia. D247-1000 1000 800 80.0 2500 600 696F7 6.0 723 84.9 86.1629 9" Dia. D247-1100 1100 880 80.0 2750 660 765F8 7.5 907 84.8 86.4789 10" Dia. D247-1200 1200 960 80.0 3000 720 835F9 9.0 1091 84.7 86.6949 10" Dia. D247-1300 1300 1040 80.0 3250 780 904Ratings based on 12.5% CO2 and +0.10" water draft at the vent.D247-1400 1400 1120 80.0 3500 840 974Freeport SeriesD247-1500 1500 1200 80.0 3750 900 1043D247-1600 1600 1280 80.0 4008 962 1113Power Burner, Forced Draft, Light OilD247-1700 1700 1360 80.0 4283 1028 1183CT-8 2.50 286 85.3 81.7249 8x12x15D247-1800 1800 1440 80.0 4563 1095 1252Ratings based on 13.0% CO2 and -0.02" water draft at the vent.D247-1900 1900 1520 80.0 4838 1161 1322#Jamaica IIID247-2000 2000 1600 80.0 5117 1228 1391Atmospheric, Inter. Ign., Natural Gas D247-2100 2100 1680 80.0 5392 1294 1461JSE310E 310 245 80.0 77.0 767 184D247-2200 2200 1760 80.0 5671 1361 1530JSE345E 345 273 80.0 77.0 854 205D247-2300 2300 1840 80.0 5942 1426 1600JSE379E 379 299 80.0 77.0 933 224D247-2400 2400 1920 80.0 6213 1491 1670Atmospheric, Standing Pilot, Natural GasD247-2500 2500 2000 80.0 6471 1553 1739JSE310S 310 245 80.0 77.0 767 184D247-2600 2600 2080 80.0 6729 1615 1809JSE345S 345 273 80.0 77.0 854 205D247-2700 2700 2160 80.0 6988 1677 1878JSE379S 379 299 80.0 77.0 933 224D247-2800 2800 2240 80.0 7246 1739 1948D247-2900 2900 2320 80.0 7504 1801 2017#Series 16D247-3000 3000 2400 80.0 7763 1863 2087Atmospheric, Inter. Ign., Natural or Propane Gas Also approved with suffix S or W.16-325 325 260 80.0 77.022616-390 390 312 80.0 77.0271HEAT TRANSFER PRODUCTS INC.16-455 455 364 80.0 77.031716-520 520 416 80.0 77.0362 STAINLESS STEEL16-585 585 468 80.0 77.0407Mod ConSeries 24Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural orForced Draft, Inter. Ign., Natural or Propane GasPropane Gas24-03 438 350 82.5 80.0 1096 263 304 7" Dia. Mod Con 300 301 283 94.0 94.0246 4" Dia.Ratings based on 9.7% CO2 and +0.10" water draft at the vent.Mod Con 500 500 470 94.0 94.0409 4" Dia.APR 2009 - 39# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)HEAT TRANSFER PRODUCTS INC.STAINLESS STEELSteam Water(MBh) (MBh)VentSize(LxWxH)Mod ConPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural orPropane GasMod Con 850 850 799 94.0 94.0695 6" Dia.Ratings based on 9.5% CO2 and -0.01" water draft at the vent.Munchkin 399M SeriesPower Burner, Direct Vent, Condensing, Induced Draft, Inter. Ign., Natural orPropane Gas399M 399 379 95.1 93.4330399VWH 399 379 95.1 93.4330LAARS HEATING SYSTEMS COMPANYCOPPER#MightyTherm Series CAtmospheric, Inter. Ign., Natural or Propane GasHH325 325 264 81.0229HH400 400 324 81.0282Outdoor, Atmospheric, Inter. Ign., Natural GasHH0400C 400 333 83.4290Indoor/OutdoorOutdoor, Atmospheric, Inter. Ign., Natural or Propane GasHH325 325 260 80.0226HH400 400 320 80.0278#MightyTherm Series EOutdoor, Atmospheric, Inter. Ign., Natural or Propane GasHH0500 500 410 82.0357HH0600 600 492 82.0428HH0715 715 587 82.0510HH0850 850 697 82.0606HH0999 999 820 82.0712HH1010 1010 829 82.0720HH1200 1200 984 82.0856HH1430 1430 1173 82.01020HH1670 1670 1370 82.01191HH1825 1825 1497 82.01301HH2200 2205 1787 81.01553HH2800 2745 2224 81.01993HH3200 3150 2552 81.02219HH3600 3645 2953 81.02567HH4000 4050 3281 81.02853HH4500 4500 3645 81.03170#MightyTherm Series IAtmospheric, Inter. Ign., Natural or Propane GasHH0500 500 405 81.0352HH0600 600 486 81.0423HH0715 715 580 81.0504HH0850 850 689 81.0599HH0999 999 810 81.0704HH1010 1010 819 81.0711HH1200 1200 972 81.0845HH1430 1430 1159 81.01007HH1670 1670 1353 81.01176HH1825 1825 1479 81.01285HH2000 2000 1640 82.01426HH2450 2450 2009 82.01747HH3050 3050 2501 82.02175HH3500 3500 2870 82.02496HH4050 4050 3321 82.02888HH4500 4500 3690 82.03209HH5000 5000 4100 82.03565BoilerModelCOPPERNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)LOCHINVAR CORPORATIONSteam Water(MBh) (MBh)VentSize(LxWxH)#Copper-FinPower Burner, Two-Stage, Forced Draft, Inter. Ign., Natural GasCBN495 495 401 82.0 81.0349 6" Dia.CBN645 645 522 82.0 81.0454 8" Dia.CBN745 745 603 82.0 81.0524 8" Dia.CBN0986 985 798 82.0 81.0694 10" Dia.CBN1256 1255 1017 82.0 81.0884 12" Dia.CBN1436 1435 1162 82.0 81.01010 12" Dia.CBN1796 1795 1454 82.0 81.01264 14" Dia.CBN2066 2065 1673 82.0 81.01455 14" Dia.Ratings based on 8.3% CO2 and -0.04" water draft at the vent.Power Burner, Two-Stage, Forced Draft, Inter. Ign., Propane GasCBL495 495 401 82.0 81.0349 6" Dia.CBL645 645 522 82.0 81.0454 8" Dia.CBL745 745 603 82.0 81.0524 8" Dia.CBL0986 985 798 82.0 81.0694 10" Dia.CBL1256 1255 1017 82.0 81.0884 12" Dia.CBL1436 1435 1162 82.0 81.01010 12" Dia.CBL1796 1795 1454 82.0 81.01264 14" Dia.CBL2066 2065 1673 82.0 81.01455 14" Dia.Ratings based on 8.3% CO2 and -0.04" water draft at the vent.Two-Stage, Atmospheric, Inter. Ign., Natural GasCBN315 315 258 83.0 82.0224CBN360 360 295 83.0 82.0257CBN399 399 328 83.0 82.0285CBN500 500 410 83.0 82.0357Two-Stage, Atmospheric, Inter. Ign., Propane GasCBL315 315 258 83.0 82.0224CBL360 360 295 83.0 82.0257CBL399 399 328 83.0 82.0285CBL500 500 410 83.0 82.0357#Copper-Fin IIPower Burner, Modulating, Outdoor, Forced Draft, Inter. Ign., Natural GasCHN401 399 335 83.5 84.0291 6" Dia.CHN501 500 420 83.5 84.0365 6" Dia.CHN651 650 546 83.5 84.0475 8" Dia.CHN751 750 630 83.5 84.0548 8" Dia.CHN0991 990 832 82.0 84.0723 10" Dia.CHN1261 1260 1058 82.0 84.0920 12" Dia.CHN1441 1440 1210 82.0 84.01052 12" Dia.CHN1801 1800 1512 82.0 84.01315 14" Dia.CHN2071 2070 1739 82.0 84.01512 14" Dia.Ratings based on 8.3% CO2 and -0.04" water draft at the vent.Power Burner, Modulating, Outdoor, Forced Draft, Inter. Ign., Propane GasCHL401 399 335 83.5 84.0291 6" Dia.CHL501 500 420 83.5 84.0365 6" Dia.CHL651 650 546 83.5 84.0475 8" Dia.CHL751 750 630 83.5 84.0548 8" Dia.CHL0991 990 832 82.0 84.0723 10" Dia.CHL1261 1260 1058 82.0 84.0920 12" Dia.CHL1441 1440 1210 82.0 84.01052 12" Dia.CHL1801 1800 1512 82.0 84.01315 14" Dia.CHL2071 2070 1739 82.0 84.01512 14" Dia.Ratings based on 8.3% CO2 and -0.04" water draft at the vent.#Intelli-FinPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural GasIBN1500 1500 1380 89.9 92.01200 6" Dia.IBN1700 1700 1564 89.9 92.01360 7" Dia.IBN2000 2000 1840 89.9 92.01600 8" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Propane GasIBL1500 1500 1380 89.9 92.01200 6" Dia.APR 2009 - 40# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelCOPPERNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)LOCHINVAR CORPORATIONSteam Water(MBh) (MBh)VentSize(LxWxH)#Intelli-FinPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Propane GasIBL1700 1700 1564 89.9 92.01360 7" Dia.IBL2000 2000 1840 89.9 92.01600 8" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.#Power FinPower Burner, Forced Draft, Inter. Ign., Natural GasPBN0502-F9 500 425 85.0 85.0370 7" Dia.PBN0752-F9 750 637 85.0 85.0554 9" Dia.PBN1002-F9 1000 850 85.0 85.0739 10" Dia.PBN1302-F9 1300 1105 85.0 85.0961 12" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.Power Burner, Modulating, Forced Draft, Inter. Ign., Natural GasPBN0502 500 425 85.0 85.0370 7" Dia.PBN0752 750 637 85.0 85.0554 9" Dia.PBN1002 1000 850 85.0 85.0739 10" Dia.PBN1302 1300 1105 85.0 85.0961 12" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.#Power-FinPower Burner, Forced Draft, Inter. Ign., Propane GasPBL0502-F9 500 425 85.0 85.0370 7" Dia.PBL0752-F9 750 637 85.0 85.0554 9" Dia.PBL1002-F9 1000 850 85.0 85.0739 10" Dia.PBL1302-F9 1300 1105 85.0 85.0961 12" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.Power Burner, Modulating, Forced Draft, Inter. Ign., Natural GasPBN1501-B9 1500 1260 83.0 84.01096 12" Dia.PBN1701-B9 1700 1428 83.0 84.01242 14" Dia.PBN2001-B9 2000 1680 83.0 84.01461 14" Dia.Ratings based on 8.2% CO2 and -0.02" water draft at the vent.PBN1501-M9 1500 1275 84.0 85.01109 6" Dia.PBN1701-M9 1700 1445 84.0 85.01257 7" Dia.PBN2001-M9 2000 1700 84.0 85.01478 8" Dia.Ratings based on 8.5% CO2 and +0.11" water draft at the vent.PBN0501 500 425 85.0 85.0370 7" Dia.PBN0751 750 637 85.0 85.0554 9" Dia.PBN1001 1000 850 85.0 85.0739 10" Dia.PBN1300 1300 1105 85.0 85.0961 12" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.Power Burner, Modulating, Forced Draft, Inter. Ign., Propane GasPBL1501-B9 1500 1260 83.0 84.01096 12" Dia.PBL1701-B9 1700 1428 83.0 84.01242 14" Dia.PBL2001-B9 2000 1680 83.0 84.01461 14" Dia.Ratings based on 8.2% CO2 and -0.02" water draft at the vent.PBL1501-M9 1500 1275 84.0 85.01109 6" Dia.PBL1701-M9 1700 1445 84.0 85.01257 7" Dia.PBL2001-M9 2000 1700 84.0 85.01478 8" Dia.Ratings based on 8.5% CO2 and +0.11" water draft at the vent.PBL0501 500 425 85.0 85.0370 7" Dia.PBL0502 500 425 85.0 85.0370 7" Dia.PBL0751 750 637 85.0 85.0554 9" Dia.PBL0752 750 637 85.0 85.0554 9" Dia.PBL1001 1000 850 85.0 85.0739 10" Dia.PBL1002 1000 850 85.0 85.0739 10" Dia.PBL1300 1300 1105 85.0 85.0961 12" Dia.PBL1302 1300 1105 85.0 85.0961 12" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.STAINLESS STEELKnight XLPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural GasKBN399 399 373 95.0 93.3324 4" Dia.KBN500 500 467 95.0 93.3406 4" Dia.NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)BoilerGas OilSteamModel(MBh) (gph)(sqft)Ratings based on 9.2% CO2 and +0.15" water draft at the vent.Net I=B=R RatingsSteam Water(MBh) (MBh)VentSize(LxWxH)KBN600 600 567 95.0 94.6493 4" Dia.KBN700 700 660 95.0 94.3574 6" Dia.KBN800 800 752 95.0 94.0654 6" Dia.Ratings based on 9.4% CO2 and +0.15" water draft at the vent.Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Propane GasKBL399 399 373 95.0 93.3324 4" Dia.KBL500 500 467 95.0 93.3406 4" Dia.Ratings based on 9.2% CO2 and +0.15" water draft at the vent.KBL600 600 567 95.0 94.6493 4" Dia.KBL700 700 660 95.0 94.3574 6" Dia.KBL800 800 752 95.0 94.0654 6" Dia.Ratings based on 9.4% CO2 and +0.15" water draft at the vent.SyncPower Burner, Modulating, Condensing, Induced Draft, Inter. Ign., Natural GasSBL1000 1000 941 94.7 94.1818 6" Dia.SBN1000 1000 941 94.7 94.1818 6" Dia.SBL1300 1300 1240 94.8 95.41078 6" Dia.SBN1300 1300 1240 94.8 95.41078 6" Dia.SBL1500 1500 1443 94.8 96.21255 6" Dia.SBN1500 1500 1443 94.8 96.21255 6" Dia.STEELNEW YORKER BOILER CO., INC.FR SeriesPower Burner, Natural Draft, Light OilFR265W 2.35 265 84.9 82.2230 8x12x15FR305W 2.60 305 83.3 83.4265 8x12x18FR350W 3.00 350 85.0 83.1304 8x12x20FR400W 3.50 400 83.8 81.8348 8x12x20FR462W 4.00 462 84.2 82.7402 8x12x25Ratings based on 12.2% CO2 and -0.02" water draft.CAST IRONP B HEAT, LLC#Series 211AAtmospheric, Inter. Ign., Natural Gas211A-04 630 504 80.0 76.9 1575 378 438211A-05 840 672 80.0 77.4 2100 504 584211A-06 1050 840 80.0 77.7 2625 630 730211A-07 1260 1008 80.0 77.8 3150 756 877211A-08 1470 1176 80.0 77.9 3675 882 1023211A-09 1680 1344 80.0 78.0 4229 1015 1169211A-10 1890 1512 80.0 78.1 4808 1154 1315211A-11 2100 1680 80.0 78.2 5392 1294 1461211A-12 2310 1848 80.0 78.2 5971 1433 1607211A-13 2520 2016 80.0 77.7 6521 1565 1753211A-14 2730 2184 80.0 77.8 7067 1696 1899211A-15 2940 2352 80.0 77.9 7608 1826 2045211A-16 3150 2520 80.0 77.9 8154 1957 2191211A-17 3360 2688 80.0 78.0 8696 2087 2337211A-18 3570 2856 80.0 78.0 9238 2217 2483211A-19 3780 3024 80.0 78.1 9783 2348 2630211A-20 3990 3192 80.0 78.1 10325 2478 2776211A-21 4200 3360 80.0 78.1 10871 2609 2922211A-22 4410 3528 80.0 78.2 11413 2739 3068211A-23 4620 3696 80.0 77.9 11958 2870 3214211A-24 4830 3864 80.0 77.9 12500 3000 3360211A-25 5040 4032 80.0 78.0 13042 3130 3506211A-26 5250 4200 80.0 78.0 13588 3261 3652211A-27 5460 4368 80.0 78.0 14129 3391 3798211A-28 5670 4536 80.0 78.1 14675 3522 3944211A-29 5880 4704 80.0 78.1 15217 3652 4090211A-30 6090 4872 80.0 78.1 15763 3783 4237APR 2009 - 41# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelCAST IRONNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)P B HEAT, LLCNet I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)#Series 211AAtmospheric, Inter. Ign., Natural Gas211A-31 6300 5040 80.0 78.1 16304 3913 4383211A-32 6510 5208 80.0 78.1 16846 4043 4529211A-33 6720 5376 80.0 78.2 17392 4174 4675211A-34 6930 5544 80.0 78.2 17933 4304 4821211A-35 7140 5712 80.0 78.2 18479 4435 4967211A-36 7350 5880 80.0 78.2 19021 4565 5113211A-37 7560 6048 80.0 78.1 19567 4696 5259211A-38 7770 6216 80.0 78.1 20108 4826 5405211A-39 7980 6384 80.0 78.1 20654 4957 5551211A-40 8190 6552 80.0 78.1 21196 5087 5697211A-41 8400 6720 80.0 78.1 21738 5217 5843211A-42 8610 6888 80.0 78.1 22283 5348 5990211A-43 8820 7056 80.0 78.1 22825 5478 6136211A-44 9030 7224 80.0 78.2 23371 5609 6282211A-45 9240 7392 80.0 78.2 23913 5739 6428211A-46 9450 7560 80.0 78.2 24458 5870 6574Atmospheric, Inter. Ign., Propane Gas211A-04 615 492 80.0 76.9 1538 369 428211A-05 820 656 80.0 77.4 2050 492 570211A-06 1025 820 80.0 77.7 2563 615 713211A-07 1230 984 80.0 77.8 3075 738 856211A-08 1435 1148 80.0 77.9 3588 861 998211A-09 1640 1312 80.0 78.0 4121 989 1141211A-10 1845 1476 80.0 78.1 4688 1125 1283211A-11 2050 1640 80.0 78.2 5258 1262 1426211A-12 2255 1804 80.0 78.2 5821 1397 1569211A-13 2460 1968 80.0 77.7 6367 1528 1711211A-14 2665 2132 80.0 77.8 6896 1655 1854211A-15 2870 2296 80.0 77.9 7429 1783 1997211A-16 3075 2460 80.0 77.9 7958 1910 2139211A-17 3280 2624 80.0 78.0 8488 2037 2282211A-18 3485 2788 80.0 78.0 9021 2165 2424211A-19 3690 2952 80.0 78.1 9550 2292 2567211A-20 3895 3116 80.0 78.1 10079 2419 2710211A-21 4100 3280 80.0 78.1 10613 2547 2852211A-22 4305 3444 80.0 78.2 11142 2674 2995211A-23 4510 3608 80.0 77.9 11671 2801 3137211A-24 4715 3772 80.0 77.9 12204 2929 3280211A-25 4920 3936 80.0 78.0 12733 3056 3423211A-26 5125 4100 80.0 78.0 13263 3183 3565211A-27 5330 4264 80.0 78.0 13796 3311 3708211A-28 5535 4428 80.0 78.1 14325 3438 3850211A-29 5740 4592 80.0 78.1 14854 3565 3993211A-30 5945 4756 80.0 78.1 15388 3693 4136211A-31 6150 4920 80.0 78.1 15917 3820 4278211A-32 6355 5084 80.0 78.1 16446 3947 4421211A-33 6560 5248 80.0 78.2 16979 4075 4563211A-34 6765 5412 80.0 78.2 17508 4202 4706211A-35 6970 5576 80.0 78.2 18038 4329 4849211A-36 7175 5740 80.0 78.2 18571 4457 4991211A-37 7380 5904 80.0 78.1 19100 4584 5134#Series 62Atmospheric, Inter. Ign., Natural or Propane Gas62-09-W/S 320 256 80.0 77.5 800 192 22362-10R-W/S 349 279 80.0 77.6 872 209 24362-10-W/S 360 288 80.0 77.6 900 216 25062-11-W/S 400 320 80.0 77.6 1000 240 27862-12-W/S 440 352 80.0 77.6 1100 264 30662-13-W/S 480 384 80.0 77.7 1200 288 33462-14-W/S 520 416 80.0 77.7 1300 312 36262-15-W/S 560 448 80.0 77.7 1400 336 390Ratings approved with suffix STDG or SPRKBoilerModelNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)#Series 64Atmospheric, Inter. Ign., Natural or Propane Gas64-07 345 286 83.0 81.024964-07 345 279 81.0 79.0 873 21064-08 399 331 83.0 81.028864-08 399 323 81.0 79.0 1010 24264-09 460 382 83.0 81.033264-09 460 373 81.0 79.0 1165 28064-10 518 430 83.0 81.037464-10 518 419 81.0 79.0 1310 31464-11 575 477 83.0 81.041564-11 575 466 81.0 79.0 1456 34964-12 633 525 83.0 81.045764-12 633 512 81.0 79.0 1601 384#Series GMAtmospheric, Inter. Ign., Natural GasGM-07-SV 342 280 82.0 79.0243GM-08-SV 399 327 82.0 79.0284Series LC/LCEForced Draft, Light OilLC-4 4.8 547 83.7 82.2 1708 410 476 9" Dia.LC-5R 5.6 649 83.7 82.8 2029 487 564 9" Dia.LC-5 6.1 707 83.7 82.8 2208 530 615 9" Dia.LC-6 7.5 868 83.7 83.1 2713 651 755 10" Dia.LC-7 8.8 1029 83.6 83.3 3217 772 895 10" Dia.LC-8 10.2 1189 83.6 83.5 3717 892 1034 10" Dia.LC-9 11.6 1350 83.6 83.6 4250 1020 1174 12" Dia.LC-10 12.8 1511 83.6 83.7 4804 1153 1314 12" Dia.LC-11 14.2 1672 83.6 83.8 5367 1288 1454 12" Dia.LC-12 15.6 1832 83.6 83.9 5917 1420 1593 12" Dia.LCE-13 17.0 1966 83.5 82.2 6358 1526 1710 14" Dia.LCE-14 18.4 2125 83.5 82.5 6875 1650 1848 14" Dia.LCE-15 19.8 2284 83.5 82.6 7388 1773 1986 14" Dia.LCE-16 21.0 2444 83.5 82.8 7908 1898 2125 14" Dia.LCE-17 22.5 2603 83.5 82.9 8421 2021 2263 14" Dia.LCE-18 24.0 2763 83.5 83.1 8938 2145 2403 16" Dia.LCE-19 25.0 2922 83.5 83.2 9454 2269 2541 16" Dia.LCE-20 26.5 3082 83.5 83.3 9971 2393 2680 16" Dia.LCE-21 28.0 3256 83.6 83.3 10533 2528 2831 16" Dia.LCE-22 29.5 3430 83.6 83.4 11096 2663 2983 16" Dia.LCE-23 31.0 3604 83.7 83.5 11658 2798 3134 16" Dia.LCE-24 32.5 3777 83.7 83.5 12217 2932 3284 16" Dia.Ratings based on 13.0% CO2 and +0.10" water draft at the vent.Power Burner, Forced Draft, Inter. Ign., Natural GasLC-4 686 547 81.2 79.8 1708 410 476 9" Dia.LC-5R 808 649 81.2 80.3 2029 487 564 9" Dia.LC-5 881 707 81.2 80.3 2208 530 615 9" Dia.LC-6 1077 868 81.1 80.6 2713 651 755 10" Dia.LC-7 1273 1029 81.1 80.8 3217 772 895 10" Dia.LC-8 1469 1189 81.1 81.0 3717 892 1034 10" Dia.LC-9 1664 1350 81.1 81.1 4250 1020 1174 12" Dia.LC-10 1860 1511 81.1 81.2 4804 1153 1314 12" Dia.LC-11 2056 1672 81.1 81.3 5367 1288 1454 12" Dia.LC-12 2252 1832 81.1 81.4 5917 1420 1593 12" Dia.LCE-13 2464 1966 81.0 79.8 6358 1526 1710 14" Dia.LCE-14 2657 2125 81.0 80.0 6875 1650 1848 14" Dia.LCE-15 2850 2284 81.0 80.2 7388 1773 1986 14" Dia.LCE-16 3043 2444 81.0 80.3 7908 1898 2125 14" Dia.LCE-17 3236 2603 81.0 80.4 8421 2021 2263 14" Dia.LCE-18 3429 2763 81.0 80.6 8938 2145 2403 16" Dia.LCE-19 3622 2922 81.0 80.7 9454 2269 2541 16" Dia.LCE-20 3815 3082 81.0 80.8 9971 2393 2680 16" Dia.LCE-21 4027 3256 81.1 80.8 10533 2528 2831 16" Dia.LCE-22 4239 3430 81.1 80.9 11096 2663 2983 16" Dia.LCE-23 4451 3604 81.2 81.0 11658 2798 3134 16" Dia.LCE-24 4663 3777 81.2 81.0 12217 2932 3284 16" Dia.APR 2009 - 42# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelCAST IRONNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)P B HEAT, LLCNet I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)Series SC/SCTForced Draft, Light OilSC/SCT-05-W/S 3.00 343 83.3 81.7 1071 257 298 7" Dia.SC/SCT-06-W/S 3.50 405 83.7 82.7 1267 304 352 9" Dia.SC/SCT-07-W/S 4.00 462 83.5 82.5 1446 347 402 9" Dia.SC/SCT-08-W/S 4.50 519 83.4 82.3 1621 389 451 9" Dia.SC/SCT-09-W/S 5.0 575 83.2 82.2 1796 431 500 10" Dia.SC/SCT-10-W/S 5.5 632 83.0 82.1 1975 474 550 10" Dia.Ratings based on 12.5% CO2 and +0.10" water draft at the vent.BoilerModelNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)Power Burner, Direct Vent, Condensing, Induced Draft, Inter. Ign., Natural orPropane GasPI-399 399 379 95.1 93.4330PATTERSON-KELLEY CO. / HARSCO CORP.ALUMINUM#MACHPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural orPropane GasC-300 300 276 92.0240 4" Dia.C-450 450 414 92.0360 5" Dia.C-750 750 713 95.0620 6" Dia.C-900 900 846 94.0736 8" Dia.C-1050 1050 987 94.0858 8" Dia.C-1500 1500 1440 96.01252 10" Dia.C-2000 2000 1920 96.01670 10" Dia.Ratings based on 9.0% CO2 and +0.22" water draft at the vent.Power Burner, Forced Draft, Inter. Ign., Natural GasSC/SCT-05-W/S 433 343 80.8 79.3 1071 257 298 7" Dia.SC/SCT-06-W/S 505 405 81.2 80.3 1267 304 352 9" Dia.SC/SCT-07-W/S 577 462 81.0 80.0 1446 347 402 9" Dia.SC/SCT-08-W/S 649 519 80.9 79.9 1621 389 451 9" Dia.SC/SCT-09-W/S 722 575 80.7 79.7 1796 431 500 10" Dia.SC/SCT-10-W/S 794 632 80.5 79.6 1975 474 550 10" Dia. COPPERRatings based on 9.5% CO2 and +0.10" water draft at the vent.#THERMIFICTC SeriesPressure Fired, Inter. Ign., Natural or Propane GasForced Draft, Light Oil N-700 700 595 85.0517 10" Dia.TC-S/W-04 8.0 900 83.5 80.4 2813 675 783 10" Dia. N-1000 1000 850 85.0739 10" Dia.TC-S/W-05 10.4 1166 83.5 80.7 3646 875 1014 10" Dia. Ratings based on 7.5% CO2 and +0.04" water draft.TC-S/W-06 12.6 1433 83.5 80.8 4538 1089 1246 10" Dia.TC-S/W-07 15.0 1699 83.5 81.0 5458 1310 1477 12" Dia.#THERMIFIC -2TC-S/W-08 17.4 1965 83.5 81.1 6358 1526 1709 12" Dia.Two-Stage, Pressure Fired, Inter. Ign., Natural or Propane GasTC-S/W-09 19.6 2232 83.5 81.1 7221 1733 1941 14" Dia. N-1500-2 1500 1275 85.01109 12" Dia.TC-S/W-10 22.0 2498 83.5 81.2 8079 1939 2172 14" Dia. N-1700-2 1700 1445 85.01257 12" Dia.TC-S/W-11 24.5 2764 83.5 81.2 8942 2146 2403 14" Dia. N-2000-2 2000 1700 85.01478 12" Dia.TC-S/W-12 26.5 3031 83.5 81.3 9804 2353 2636 14" Dia. Ratings based on 7.5% CO2 and -0.04" water draft.TC-S/W-13 29.0 3297 83.5 81.3 10667 2560 2867 14" Dia. #THERMIFIC-MFDTC-S/W-14 31.5 3563 83.5 81.3 11525 2766 3098 16" Dia.Power Burner, Modulating, Forced Draft, Inter. Ign., Natural or Propane GasTC-S/W-15 33.5 3830 83.5 81.4 12392 2974 3330 16" Dia.N-750 MFD 750 638 85.0555 4" Dia.TC-S/W-16 36.0 4096 83.5 81.4 13250 3180 3562 16" Dia.N-1000 MFD 1000 850 85.0739 4" Dia.TC-S/W-17 38.5 4362 83.5 81.4 14113 3387 3793 18" Dia.N-1500 MFD 1500 1275 85.01109 6" Dia.TC-S/W-18 40.5 4629 83.5 81.4 14975 3594 4025 18" Dia.N-2000 MFD 2000 1700 85.01478 6" Dia.Ratings based on 12.3% CO2 and +0.10" water draft at the vent.N-2500 MFD 2500 2200 88.01913 10" Dia.Ratings are also approved for boilers with prefix G, GO or LO.N-3000 MFD 3000 2640 88.02296 10" Dia.Power Burner, Forced Draft, Inter. Ign., Natural Gas Ratings based on 8.5% CO2 and +1.00" water draft at the vent.TC-S/W-04 1154 900 81.0 78.0 2813 675 783 10" Dia.TC-S/W-05 1491 1166 81.0 78.2 3646 875 1014 10" Dia.TC-S/W-06 1827 1433 81.0 78.4 4538 1089 1246 10" Dia. PENNCO, ECR INTERNATIONAL, INC.TC-S/W-07 2163 1699 81.0 78.5 5458 1310 1477 12" Dia. CAST IRONTC-S/W-08 2499 1965 81.0 78.6 6358 1526 1709 12" Dia.TC-S/W-09 2836 2232 81.0 78.7 7221 1733 1941 14" Dia. #Series 41HTC-S/W-10 3172 2498 81.0 78.8 8079 1939 2172 14" Dia.Atmospheric, Inter. Ign., Natural GasTC-S/W-11 3508 2764 81.0 78.8 8942 2146 2403 14" Dia. 41H-0300 300 240 80.0 750 180 209TC-S/W-12 3844 3031 81.0 78.8 9804 2353 2636 14" Dia. 41H-0400 400 320 80.0 1000 240 278TC-S/W-13 4180 3297 81.0 78.9 10667 2560 2867 14" Dia. 41H-0500 500 400 80.0 1250 300 348TC-S/W-14 4517 3563 81.0 78.9 11525 2766 3098 16" Dia. 41H-0600 600 480 80.0 1500 360 417TC-S/W-15 4853 3830 81.0 78.9 12392 2974 3330 16" Dia. 41H-0700 700 560 80.0 1750 420 487TC-S/W-16 5189 4096 81.0 78.9 13250 3180 3562 16" Dia. 41H-0800 800 640 80.0 2000 480 557TC-S/W-17 5525 4362 81.0 79.0 14113 3387 3793 18" Dia. 41H-0900 900 720 80.0 2250 540 626TC-S/W-18 5862 4629 81.0 79.0 14975 3594 4025 18" Dia. 41H-1000 1000 800 80.0 2500 600 696Ratings based on 9.5% CO2 and +0.10" water draft at the vent.41H-1100 1100 880 80.0 2750 660 765Ratings are also approved for boilers with prefix G, GO or LO.41H-1200 1200 960 80.0 3000 720 835Water and Steam Series EC/ECT41H-1300 1300 1040 80.0 3250 780 90441H-1400 1400 1120 80.0 3500 840 974Natural Draft, Light Oil 41H-1500 1500 1200 80.0 3750 900 1043EC/ECT-05-250-W/S 2.50 286 84.1 81.9 896 215 249 8x12x20 41H-1600 1600 1280 80.0 4008 962 1113EC/ECT-06-275-W/S 2.75 321 84.4 83.3 1004 241 279 8x12x20 41H-1700 1700 1360 80.0 4283 1028 1183EC/ECT-06-300-W/S 3.00 347 83.7 82.5 1083 261 302 8x12x20 41H-1800 1800 1440 80.0 4563 1095 1252Ratings based on 12.5% CO2 and -0.02" water draft.41H-1900 1900 1520 80.0 4838 1161 1322STAINLESS STEEL41H-2000 2000 1600 80.0 5117 1228 139141H-2100 2100 1680 80.0 5392 1294 1461PINNACLE SERIES41H-2200 2200 1760 80.0 5671 1361 1530APR 2009 - 43# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)PENNCO, ECR INTERNATIONAL, INC.CAST IRONCOMMERCIAL BOILERSVentSize(LxWxH)NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)H4902B-CHX 900 882 98.0 98.0767 2" Dia.H8902B-CHX 900 882 98.0 98.0767 2" Dia.H3992B-CHX 990 970 98.0 98.0843 2" Dia.H4992B-CHX 990 970 98.0 98.0843 2" Dia.#Series 41HH41262B-CHX 1260 1235 98.0 98.01074 2" Dia.Atmospheric, Inter. Ign., Natural GasH91262B-CHX 1260 1235 98.0 98.01074 2" Dia.41H-2300 2300 1840 80.0 5942 1426 1600Induced Draft, Inter. Ign., Natural or Propane Gas41H-2400 2400 1920 80.0 6213 1491 1670H3302*B 300 252 84.0 84.0219 2" Dia.41H-2500 2500 2000 80.0 6471 1553 1739H3302*BE 300 261 87.0 87.0227 2" Dia.41H-2600 2600 2080 80.0 6729 1615 1809H4302*B 300 252 84.0219 2" Dia.41H-2700 2700 2160 80.0 6988 1677 1878H4302*BE 300 261 87.0227 2" Dia.41H-2800 2800 2240 80.0 7246 1739 1948H3402*B 399 335 84.0 84.0291 2" Dia.41H-2900 2900 2320 80.0 7504 1801 2017H3402*BE 399 347 87.0 87.0302 2" Dia.41H-3000 3000 2400 80.0 7763 1863 2087H4402*B 399 335 84.0291 2" Dia.Also approved with suffix SI or WI.H4402*BE 399 347 87.0302 2" Dia.RAYPAK, INC.H3502*B 500 420 84.0 84.0365 2" Dia.H3502*BE 500 435 87.0 87.0378 2" Dia.H4502*B 500 420 84.0365 2" Dia.COPPERH4502*BE 500 435 87.0378 2" Dia.#ADB SeriesH3652*B 650 546 84.0 84.0475 2" Dia.Atmospheric, Inter. Ign., Natural or Propane Gas H3652*BE 650 566 87.0 87.0492 2" Dia.H500 500 420 84.0 84.0365H4652*B 650 546 84.0475 2" Dia.H751 750 630 84.0 84.0548H4652*BE 650 566 87.0492 2" Dia.H1001 1000 840 84.0 84.0730H3752*B 750 630 84.0 84.0548 2" Dia.H1501 1499 1260 84.0 84.01096H3752*BE 750 653 87.0 87.0568 2" Dia.Condensing, Induced Draft, Inter. Ign., Natural or Propane Gas H4752*B 750 630 84.0548 2" Dia.H500CHX 500 485 97.0 97.0422 2" Dia. H4752*BE 750 653 87.0568 2" Dia.H751CHX 750 728 97.0 97.0633 2" Dia. H3902*B 900 756 84.0 84.0657 2" Dia.H1001CHX 1000 970 97.0 97.0843 2" Dia. H3902*BE 900 783 87.0 87.0681 2" Dia.H1501CHX 1499 1455 97.0 97.01265 2" Dia. H4902*B 900 756 84.0657 2" Dia.H4902*BE 900 783 87.0681 2" Dia.#Delta LimitedH4992*B 990 831 84.0723 2" Dia.Atmospheric, Inter. Ign., Natural or Propane Gas H4992*BE 990 861 87.0749 2" Dia.H3-399B* 399 327 82.0 82.0284H8992*B 990 831 84.0 84.0723 2" Dia.H4-399B* 399 327 82.0 82.0284H8992*BE 990 861 87.0 87.0749 2" Dia.H3-499B* 500 410 82.0 82.0357H41262*B 1260 1058 84.0920 2" Dia.H4-499B* 500 410 82.0 82.0357H41262*BE 1260 1096 87.0953 2" Dia.H3-649B* 650 533 82.0 82.0463H91262*B 1260 1058 84.0 84.0920 2" Dia.H4-649B* 650 533 82.0 82.0463H91262*BE 1260 1096 87.0 87.0953 2" Dia.H3-749B* 750 615 82.0 82.0535H41532*B 1530 1285 84.01117 2" Dia.H4-749B* 750 615 82.0 82.0535H41532*BE 1530 1331 87.01157 2" Dia.H3-899B* 900 738 82.0 82.0642H41532B-CHX 1530 1499 98.01303 2" Dia.H4-899B* 900 738 82.0 82.0642H91532*B 1530 1285 84.0 84.01117 2" Dia.H3-989B* 990 811 82.0 82.0705H91532*BE 1530 1331 87.0 87.01157 2" Dia.H4-989B* 990 811 82.0 82.0705H41802*B 1800 1512 84.01315 2" Dia.H3-1259B* 1260 1033 82.0 82.0898H41802*BE 1800 1566 87.01362 2" Dia.H4-1259B* 1260 1033 82.0 82.0898H41802B-CHX 1800 1764 98.01534 2" Dia.H3-1529B* 1530 1254 82.0 82.01090H91802*B 1800 1512 84.0 84.01315 2" Dia.H4-1529B* 1530 1254 82.0 82.01090H91802*BE 1800 1566 87.0 87.01362 2" Dia.H3-1799B* 1800 1476 82.0 82.01283H42002*B 1999 1679 84.01460 2" Dia.H4-1799B* 1800 1476 82.0 82.01283H42002*BE 1999 1739 87.01512 2" Dia.H3-1999B* 1999 1639 82.0 82.01425H42002B-CHX 1999 1959 98.01703 2" Dia.H4-1999B* 1999 1639 82.0 82.01425H92002*B 1999 1679 84.0 84.01460 2" Dia.H3-2069B* 2070 1697 82.0 82.01476H92002*BE 1999 1739 87.0 87.01512 2" Dia.H4-2069B* 2070 1697 82.0 82.01476H42072*B 2070 1738 84.01511 2" Dia.H3-2339B* 2340 1918 82.0 82.01668H42072*BE 2070 1801 87.01566 2" Dia.H4-2339B* 2340 1918 82.0 82.01668H92072*B 2070 1738 84.0 84.01511 2" Dia.Also approved with prefix H1 - H6.H92072*BE 2070 1801 87.0 87.01566 2" Dia.H42342*B 2340 1965 84.01709 2" Dia.#HI Delta SeriesH42342*BE 2340 2036 87.01770 2" Dia.Condensing, Induced Draft, Inter. Ign., Natural or Propane GasH92342*B 2340 1965 84.0 84.01709 2" Dia.H3402B-CHX 399 391 98.0 98.0340 2" Dia.H92342*BE 2340 2036 87.0 87.01770 2" Dia.H4402B-CHX 399 391 98.0 98.0340 2" Dia.Also approved with prefix H1 - H6.H3502B-CHX 500 490 98.0 98.0426 2" Dia.H4502B-CHX 500 490 98.0 98.0426 2" Dia. #MVBH3652B-CHX 650 637 98.0 98.0554 2" Dia.Outdoor, Induced Draft, Inter. Ign., Natural or Propane GasH4652B-CHX 650 637 98.0 98.0554 2" Dia. H7-503 500 435 87.0 87.0378 5" Dia.H3752B-CHX 750 735 98.0 98.0639 2" Dia. H7-504 500 420 84.0 84.0365 5" Dia.H4752B-CHX 750 735 98.0 98.0639 2" Dia. H7-753 750 653 87.0 87.0568 6" Dia.APR 2009 - 44# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelCOPPERNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)RAYPAK, INC.Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)#MVBOutdoor, Induced Draft, Inter. Ign., Natural or Propane GasH7-754 750 630 84.0 84.0548 6" Dia.H7-1003 999 869 87.0 87.0756 7" Dia.H7-1104 1100 924 84.0 84.0803 7" Dia.H7-1253 1250 1088 87.0 87.0946 8" Dia.H7-1503 1500 1305 87.0 87.01135 9" Dia.H7-1504 1500 1260 84.0 84.01096 9" Dia.H7-1753 1750 1523 87.0 87.01324 9" Dia.H7-2003 1999 1739 87.0 87.01512 10" Dia.H7-2004 1999 1679 84.0 84.01460 10" Dia.#Raytherm IndoorAtmospheric, Inter. Ign., Natural GasH-0962A 962 789 82.0 82.0686H-1125A 1125 922 82.0 82.0802H-1223A 1223 1002 82.0 82.0871H-1336A 1337 1096 82.0 82.0953H-1468A 1467 1203 82.0 82.01046H-1631A 1630 1337 82.0 82.01163H-1826A 1826 1497 82.0 82.01302Also approved with prefix H1-H6Atmospheric, Inter. Ign., Natural or Propane GasH-0962A 885 727 82.0 82.0632H-1125A 1035 849 82.0 82.0738H-1223A 1125 923 82.0 82.0803H-1336A 1233 1012 82.0 82.0880H-1468A 1350 1107 82.0 82.0963H-1631A 1500 1230 82.0 82.01070H-1826A 1680 1378 82.0 82.01198H-2100B 1999 1640 82.0 82.01426H-2100A 2100 1722 82.0 82.01497H-2500A 2499 2050 82.0 82.01783H-3001A 3000 2460 82.0 82.02139H-3500A 3500 2870 82.0 82.02496H-4001A 4000 3280 82.0 82.02852#Raytherm Indoor & OutdoorAtmospheric, Inter. Ign., Natural or Propane GasH-0330 334 274 82.0 82.0238H-0331 334 274 82.0 82.0238H-0400 399 328 82.0 82.0285H-0401 399 328 82.0 82.0285H-0514A 512 420 82.0 82.0365H-0624A 627 515 82.0 82.0448H-0724A 726 596 82.0 82.0518H-0824A 825 677 82.0 82.0589Also approved with prefix H1 - H6.Outdoor, Atmospheric, Inter. Ign., Propane GasH-0514A- 481 394 82.0 82.0343H-0624A- 589 483 82.0 82.0420H-724A- 682 559 82.0 82.0486H-0824A- 775 636 82.0 82.0553Also approved with prefix H1-H6#Raytherm OutdoorAtmospheric, Inter. Ign., Natural or Propane GasH-0926A 926 760 82.0 82.0661H-1083A 1083 889 82.0 82.0773H-1178A 1178 966 82.0 82.0840H-1287A 1287 1056 82.0 82.0918H-1414A 1413 1159 82.0 82.01008H-1571A 1570 1288 82.0 82.01120H-1758A 1758 1442 82.0 82.01254Outdoor, Atmospheric, Inter. Ign., Propane GasNameplateInputGrossOutput(MBh)BoilerGas OilModel(MBh) (gph)H-0926A 726CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam Steam Water(sqft) (MBh) (MBh)885 82.0 82.0631H-1083A 1035 849 82.0 82.0738H-1178A 1126 923 82.0 82.0803H-1287A 1233 1011 82.0 82.0879H-1414A 1350 1107 82.0 82.0963H-1571A 1500 1230 82.0 82.01070H-1758A 1680 1378 82.0 82.01198Also approved with prefix H1-H6COPPERRBI WATER HEATERSDIVISION OF MESTEK, INC.VentSize(LxWxH)#8800 SeriesAtmospheric, Standing Pilot, Natural GasHB2000 2000 1640 82.01426HB2400 2400 1968 82.01711HB2800 2800 2296 82.01997HB3200 3200 2624 82.02282HB3600 3600 2952 82.02567HB4000 4000 3280 82.02852#8900 SeriesAtmospheric, Standing Pilot, Natural GasHB420 420 340 81.0296HB530 530 429 81.0373HB630 630 510 81.0443HB735 735 595 81.0517HB840 840 680 81.0591HB950 950 770 81.0670HB1050 1050 851 81.0740HB1160 1160 940 81.0817HB1260 1260 1021 81.0888HB1370 1370 1110 81.0965HB1470 1470 1191 81.01036HB1580 1580 1280 81.01113HB1685 1685 1365 81.01187HB1790 1790 1450 81.01261HB1900 1900 1539 81.01338#Dominator SeriesAtmospheric, Standing Pilot, Natural or Propane GasDB300 300 252 84.0 80.2219DB400 399 335 84.0 80.8291DB600 600 504 84.0 81.7438DB750 750 630 84.0 82.0548DB900 900 756 84.0 82.0657DB1050 1050 882 84.0 82.0767DB1350 1350 1134 84.0 82.0986DB1500 1500 1260 84.0 82.01097DB1950 1950 1638 84.0 82.01424DB2100 2100 1764 84.0 82.11534Futera FusionCondensing, Forced Draft, Standing Pilot, Natural or Propane GasCB-500 500 487 97.0 97.3423 7" Dia.CB-750 750 730 96.3 97.3635 7" Dia.CB-1000 1000 974 95.9 97.4847 7" Dia.CB-1250 1250 1218 95.7 97.41059 8" Dia.CB-1500 1500 1462 95.5 97.51271 8" Dia.CB-1750 1750 1706 95.4 97.51483 10" Dia.CB-2000 1999 1950 95.3 97.51696 10" Dia.Ratings based on 11.0% CO2 and +0.10" water draft at the vent.#Futera II SeriesPower Burner, Forced Draft, Inter. Ign., Natural or Propane GasFH500 500 425 85.0370FH750 750 638 85.0555FH1000 1000 850 85.0740APR 2009 - 45# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelCOPPERNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)RBI WATER HEATERSDIVISION OF MESTEK, INC.Steam Water(MBh) (MBh)VentSize(LxWxH)#Futera II SeriesPower Burner, Forced Draft, Inter. Ign., Natural or Propane GasFH1250 1250 1062 85.0924FH1500 1500 1275 85.01109FH1750 1750 1488 85.01295FH1950 1950 1658 85.01442XLFPower Burner, Modulating, Forced Draft, Inter. Ign., Natural GasMB/MW3000 3000 2622 87.4 85.62280 8" Dia.MB/MW4000 4000 3480 87.0 85.83026 10" Dia.Ratings based on 9.0% CO2 and +10.00" water draft at the vent.SLANT/FIN CORPORATIONALUMINUMJaguarPower Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural GasJ-390 390 352 91.6 90.2306 4" Dia.Ratings based on 9.4% CO2 and +0.10" water draft at the vent.CAST IRONEutectic EC-20Power Burner, Forced Draft, Light OilEC-27 2.25 269 87.4 85.3234 7" Dia.EC-28 2.50 298 84.7 85.3259 7" Dia.Ratings based on 13.0% CO2 and +0.02" water draft at the vent.Eutectic EC-20 GasPower Burner, Forced Draft, Inter. Ign., Natural GasEC-27 325 269 84.7 82.7234 7" Dia.EC-28 361 298 84.7 82.7259 7" Dia.Ratings based on 10.0% CO2 and +0.02" water draft at the vent.#Galaxy SeriesDamper, Atmospheric, Inter. Ign., Natural GasGXH-300HD 300 243 81.0211GXH-300HED 300 243 81.0211GXH-300HEDPZ 300 243 81.0 758 182GG-350HEDP 350 291 83.0253Damper, Atmospheric, Inter. Ign., Natural or Propane GasGG-300EDP 300 240 80.0209GXH-300D 300 240 80.0209GG-325EDP 325 260 80.0226GG-350EDP 350 280 80.0243GG-375HEDP 375 304 81.0264GG-399HEDP 399 327 82.0284Damper, Atmospheric, Standing Pilot, Natural GasGXH-300HDPZ 300 243 81.0 758 182Damper, Atmospheric, Standing Pilot, Natural or Propane GasGG-300DP 300 240 80.0209Damper, Cont. Circ., Atmospheric, Inter. Ign., Natural GasGG-350HEDS 350 291 83.0253Damper, Cont. Circ., Atmospheric, Inter. Ign., Natural or Propane GasGG-300EDS 300 240 80.0209GG-325EDS 325 260 80.0226GG-350EDS 350 280 80.0243GG-375HEDS 375 304 81.0264GG-399HEDS 399 327 82.0284Damper, Cont. Circ., Atmospheric, Standing Pilot, Natural or Propane GasGG-300DS 300 240 80.0209#GGHT Caravan SeriesBoilerModelNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)Atmospheric, Inter. Ign., Natural GasGGHT-700E 700 581 83.0505GGHT-1050E 1050 872 83.0758GGHT-1400E 1400 1162 83.01010GGHT-1750E 1750 1453 83.01263GGHT-2100E 2100 1743 83.01516GGHT-2540E 2450 2043 83.01768GGHT-2800AE 2800 2324 83.02021GGHT-3150E 3150 2615 83.02273GGHT-3500E 3500 2905 83.02526Atmospheric, Inter. Ign., Natural or Propane GasGGHT-750E 750 608 81.0529GGHT-800E 798 654 82.0569GGHT-1125E 1125 912 81.0793GGHT-1200E 1197 981 82.0853GGHT-1500E 1500 1216 81.01057GGHT-1600E 1596 1308 82.01137GGHT-1875E 1875 1520 81.01321GGHT-2000E 1995 1635 82.01422GGHT-2250E 2250 1824 81.01586GGHT-2400E 2394 1962 82.01706GGHT-2625E 2625 2128 81.01850GGHT-2800E 2793 2289 83.01990GGHT-3000E 3000 2432 81.02115GGHT-3200E 3192 2616 82.02275GGHT-3375E 3375 2736 81.02379GGHT-3600E 3591 2943 82.02559GGHT-3750E 3750 3040 81.02643GGHT-4000E 3990 3270 82.02843#GGT Caravan SeriesAtmospheric, Inter. Ign., Natural or Propane GasGGT-400E 400 322 82.0280GGT-500E 500 402 80.4350GGT-600E 600 600 80.0417GGT-900E 900 720 80.0626GGT-1200E 1200 960 80.0834GGT-1500E 1500 1200 80.01043Atmospheric, Standing Pilot, Natural or Propane GasGGT-400 400 322 82.0280GGT-500 500 402 80.4350GGT-600 600 480 80.0417GGT-900 900 720 80.0626GGT-1200 1200 960 80.0834GGT-1500 1500 1200 80.01043#GXHT Caravan SeriesAtmospheric, Standing Pilot, Natural or Propane GasGXHT-380Z 380 304 80.0 950 228GXHT-500Z 504 403 80.0 1258 302GXHT-750Z 756 605 80.0 1892 454#GXHT-HZ Steam Caravan SeriesAtmospheric, Standing Pilot, Natural GasGXHT-600HZ 600 486 81.0 1521 365GXHT-900HZ 900 729 81.0 2279 547GXHT-1200HZ 1200 972 81.0 3038 729GXHT-1500HZ 1500 1215 81.0 3796 911Intrepid Dual Fuel - GasPower Burner, Natural Draft, Inter. Ign., Natural GasTRF-50 310 250 83.1 80.4 781 188 217 8x12x15TRF-50 339 271 82.3 79.9236 8x12x15TRF-60 375 296 82.6 79.1 925 222 257 8x12x15TRF-70 399 310 82.3 77.8 969 233 270 8x12x15TRF-60 411 324 81.7 79.0282 8x12x15TRF-70 447 348 82.3 77.8 1088 261 303 8x12x15TRF-70 484 378 81.0 78.1329 8x12x15Ratings based on 9.5% CO2.APR 2009 - 46# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)SLANT/FIN CORPORATIONCAST IRONSteam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)LDF-70 3.10 348 84.8 80.2 1088 261 303 8x12x15LDF-70 3.35 378 83.5 80.6329 8x12x15Ratings based on 12.3% CO2 and -0.02" water draft.Intrepid Dual Fuel - OilLiberty Series Model LPower Burner, Natural Draft, Light OilPower Burner, Natural Draft, Light OilTRF-50 2.15 250 85.7 82.9 781 188 217 8x12x15 LD-50 2.15 250 85.9 82.5 783 188 217 8x12x15TRF-50 2.35 271 84.8 82.4236 8x12x15 LD-50 2.35 272 85.2 82.7237 8x12x15TRF-60 2.60 296 85.2 81.6 925 222 257 8x12x15 LD-60 2.60 298 85.8 81.9 933 224 259 8x12x15TRF-60 2.85 324 84.2 81.5282 8x12x15 LD-60 2.85 326 84.7 81.8283 8x12x15TRF-70 3.00 337 84.8 80.2 1053 253 293 8x12x15 LD-70 3.00 337 84.8 80.2 1054 253 8x12x15TRF-70 3.10 348 84.8 80.2 1088 261 303 8x12x15 LD-70 3.00 399 83.5 80.7294 8x12x15TRF-70 3.35 378 83.5 80.6329 8x12x15 LD-70 3.10 354 85.5 81.5 1108 266 308 8x12x15Ratings based on 12.3% CO2.LD-70 3.35 381 84.2 81.2331 8x12x15Intrepid SeriesRatings based on 13.0% CO2 and -0.02" water draft.Power Burner, Natural Draft, Light Oil LWDF Caravan Series (Dual Fuel)TR-50 2.15 250 85.9 82.5 783 188 217 8x12x15Power Burner, Natural Draft, Inter. Ign., Natural GasTR-50 2.35 272 85.2 82.7237 8x12x15 LWDF-600-2-5 620 500 83.3 80.4435 12x12x20TR-60 2.60 298 85.8 81.9 933 224 259 8x12x15 LWDF-750-2-6 750 592 83.2 79.1515 12x12x20TR-60 2.85 326 84.7 81.8283 8x12x15 LWDF-850-2-7 798 620 82.9 77.8539 12x16x20TR-70 3.00 399 83.5 80.7294 8x12x15 LWDF-900-3-5 930 750 83.3 80.4652 12x16x20TR-70 3.00 337 84.8 80.2 1054 253 8x12x15 LWDF-1100-3-6 1125 888 83.2 79.1772 16x16x20TR-70 3.10 354 85.5 81.5 1108 266 308 8x12x15 LWDF-1300-3-7 1197 931 82.9 77.8810 16x16x20TR-70 3.35 381 84.2 81.2331 8x12x15 LWDF-1700-4-7 1596 1241 82.9 77.81079 16x20x25Ratings based on 13.0% CO2 and -0.02" water draft.LWDF-2100-5-7 1995 1551 82.9 77.81349 16x20x25LWDF-2500-6-7 2394 1861 82.9 77.81618 20x20x25LDWO Caravan SeriesLWDF-2900-7-7 2793 2172 82.9 77.81889 20x20x25Power Burner, Natural Draft, Light OilLWDF-3400-8-7 3192 2482 82.9 77.82158 20x20x25LDWO-600-2-5 4.30 500 85.9 82.5435 12x12x20 Ratings based on 9.5% CO2 and -0.02" water draft.LDWO-750-2-6 5.2 596 85.8 81.9518 12x12x20Power Burner, Natural Draft, Light OilLDWO-850-2-7 6.0 684 85.5 81.5595 12x16x20LWDF-600-2-5 4.30 500 85.9 82.9435 12x12x20LDWO-900-3-5 6.4 750 85.9 82.5652 12x16x20LWDF-750-2-6 5.2 592 85.8 81.6515 12x12x20LDWO-1100-3-6 7.8 894 85.8 81.9777 16x16x20LWDF-850-2-7 6.0 674 85.5 80.2586 12x16x20LDWO-1300-3-7 9.0 1026 85.5 81.5892 16x16x20LWDF-900-3-5 6.4 750 85.9 82.9652 12x16x20LDWO-1700-4-7 12.0 1368 85.5 81.51190 16x20x25LWDF-1100-3-6 7.8 888 85.8 81.6772 16x16x20LDWO-2100-5-7 15.0 1710 85.5 81.51487 16x20x25LWDF-1300-3-7 9.0 1011 84.5 80.2879 16x16x20LDWO-2500-6-7 18.0 2052 85.5 81.51784 20x20x25LWDF-1700-4-7 12.0 1348 85.5 80.21172 16x20x25LDWO-2900-7-7 21.0 2394 85.5 81.52082 20x20x25LWDF-2100-5-7 15.0 1685 85.5 80.21465 16x20x25LDWO-3400-8-7 24.0 2736 85.5 81.52379 20x24x25LWDF-2500-6-7 18.0 2022 85.5 80.21758 20x20x25Ratings based on 13.0% CO2 and -0.02" water draft.LWDF-2900-7-7 21.0 2359 85.5 80.22051 20x20x25LDZO Caravan SeriesLWDF-3400-8-7 24.0 2696 85.5 80.22344 20x20x25Power Burner, Natural Draft, Light Oil Ratings based on 12.3% CO2 and -0.02" water draft.LDZO-600-2-5 4.30 500 85.9 82.5 1563 375 12x12x20LZDF Caravan Series (Dual Fuel)LDZO-750-2-6 5.2 596 85.8 81.9 1863 447 12x12x20Power Burner, Natural Draft, Inter. Ign., Natural GasLDZO-850-2-7 6.0 684 85.5 81.5 2138 513 12x16x20LZDF-600-2-5 620 500 83.3 80.4 1563 375 12x12x20LDZO-900-3-5 6.4 750 85.9 82.5 2346 563 12x16x20LZDF-750-2-6 750 592 83.2 79.1 1850 444 12x12x20LDZO-1100-3-6 7.8 894 85.8 81.9 2796 671 16x16x20LZDF-850-2-7 798 620 82.9 77.8 1938 465 12x16x20LDZO-1300-3-7 9.0 1026 85.5 81.5 3208 770 16x16x20LZDF-900-3-5 930 750 83.3 80.4 2346 563 12x16x20LDZO-1700-4-7 12.0 1368 85.5 81.5 4313 1035 16x20x25LZDF-1100-3-6 1125 888 83.2 79.1 2775 666 16x16x20LDZO-2100-5-7 15.0 1710 85.5 81.5 5496 1319 16x20x25LZDF-1300-3-7 1197 931 82.9 77.8 2908 698 16x16x20Ratings based on 13.0% CO2 and -0.02" water draft.LZD-1700-4-7 1596 1241 82.9 77.8 3879 931 16x20x25Liberty Dual Fuel SeriesLZD-2100-5-7 1995 1551 82.9 77.8 4946 1187 16x20x25Power Burner, Natural Draft, Inter. Ign., Natural Gas Ratings based on 9.5% CO2 and -0.02" water draft.LDF-50 310 250 83.1 80.4 783 188 217 8x12x15Power Burner, Natural Draft, Light OilLDF-50 339 271 82.3 79.9236 8x12x15 LZDF-600-2-5 4.30 500 85.9 82.9 1563 375 12x12x20LDF-60 375 296 82.6 79.1 925 222 257 8x12x15 LZDF-750-2-6 5.2 592 85.8 81.6 1850 444 12x12x20LDF-70 399 310 82.3 77.8 971 233 270 8x12x15 LZDF-850-2-7 6.0 674 85.5 80.2 2108 506 12x16x20LDF-60 411 324 81.7 79.0282 8x12x15 LZDF-900-3-5 6.4 750 85.9 82.9 2346 563 12x16x20LDF-70 447 348 82.3 77.8 1088 261 303 8x12x15 LZDF-1100-3-6 7.8 888 85.8 81.6 2775 666 16x16x20LDF-70 484 378 81.0 78.1329 8x12x15 LZDF-1300-3-7 9.0 1011 85.5 80.2 3158 758 16x16x20Ratings based on 9.5% CO2 and -0.02" water draft.Power Burner, Natural Draft, Light OilLZDF-1700-4-7LZDF-2100-5-712.015.01348168585.585.580.280.2424254081018129816x20x2516x20x25LDF-50 2.15 250 85.7 82.9 783 188 217 8x12x15 Ratings based on 12.3% CO2 and -0.02" water draft.LDF-50 2.35 271 84.8 82.4236 8x12x15LDF-60 2.60 296 85.2 81.6 925 222 257 8x12x15SMITH CAST IRON BOILERSLDF-60 2.85 324 84.2 81.5282 8x12x15LDF-70 3.00 337 84.8 80.2 1054 253 293 8x12x15 CAST IRONAPR 2009 - 47# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)SMITH CAST IRON BOILERSCAST IRONSteam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)19 SeriesPower Burner, Forced Draft, Inter. Ign., Natural Gas19-S/W-03 375 297 81.6 79.2 929 223 258 6" Dia.19-S/W-04 520 413 82.7 79.4 1292 310 359 7" Dia.19-S/W-05 660 529 82.6 80.0 1654 397 460 8" Dia.19-S/W-06 801 644 82.6 80.4 2013 483 560 8" Dia.19-S/W-07 942 760 82.6 80.7 2375 570 661 9" Dia.19-S/W-08 1082 878 82.6 80.9 2738 657 762 10" Dia.19-S/W-09 1223 992 82.6 81.1 3100 744 863 10" Dia.19-S/W-10 1364 1107 82.6 81.2 3456 830 963 10" Dia.19-S/W-11 1505 1223 82.6 81.3 3821 917 1063 10" Dia.19-S/W-12 1645 1339 82.6 81.4 4213 1011 1164 12" Dia.Ratings based on 9.7% CO2 and +0.10" water draft at the vent.Power Burner, Forced Draft, Light Oil19A-S/W-03 2.60 297 84.2 81.6 929 223 258 7" Dia.19A-S/W-04 3.60 413 85.2 81.9 1292 310 359 7" Dia.19A-S/W-05 5.0 575 84.6 81.8 1796 431 500 8" Dia.19A-S/W-06 6.5 738 84.2 81.7 2308 554 642 8" Dia.19A-S/W-07 7.9 901 84.0 81.7 2817 676 783 9" Dia.19A-S/W-08 9.3 1063 83.8 81.7 3321 797 924 10" Dia.19A-S/W-09 10.8 1226 83.7 81.6 3883 920 1066 10" Dia.19A-S/W-10 12.2 1388 83.6 81.6 4383 1052 1207 10" Dia.19A/S/W-11 13.6 1551 83.6 81.6 4946 1187 1349 12" Dia.19A-S/W-12 15.0 1713 83.5 81.6 5508 1322 1490 12" Dia.Ratings based on 12.5% CO2 and +0.10" water draft at the vent.NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)28A-S/W-15 4853 3830 81.0 78.9 12392 2974 3330 16" Dia.28A-S/W-16 5189 4096 81.0 78.9 13250 3180 3562 16" Dia.28A-S/W-17 5525 4362 81.0 79.0 14113 3387 3793 18" Dia.28A-S/W-18 5862 4629 81.0 79.0 14975 3594 4025 18" Dia.Ratings based on 9.5% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.Power Burner, Forced Draft, Light Oil28A-S/W-04 8.0 900 83.5 80.4 2813 675 783 10" Dia.28A-S/W-05 10.4 1166 83.5 80.7 3646 875 1014 10" Dia.28A-S/W-06 12.6 1433 83.5 80.8 4538 1089 1246 10" Dia.28A-S/W-07 15.0 1699 83.5 81.0 5458 1310 1477 12" Dia.28A-S/W-08 17.4 1965 83.5 81.1 6358 1526 1709 12" Dia.28A-S/W-09 19.6 2232 83.5 81.1 7221 1733 1941 14" Dia.28A-S/W-10 22.0 2498 83.5 81.2 8079 1939 2172 14" Dia.28A-S/W-11 24.5 2764 83.5 81.2 8942 2146 2403 14" Dia.28A-S/W-12 26.5 3031 83.5 81.3 9804 2353 2636 14" Dia.28A-S/W-13 29.0 3297 83.5 81.3 10667 2560 2867 14" Dia.28A-S/W-14 31.5 3563 83.5 81.3 11525 2766 3098 16" Dia.28A-S/W-15 33.5 3830 83.5 81.4 12392 2974 3330 16" Dia.28A-S/W-16 36.0 4096 83.5 81.4 13250 3180 3562 16" Dia.28A-S/W-17 38.5 4362 83.5 81.4 14113 3387 3793 18" Dia.28A-S/W-18 40.5 4629 83.5 81.4 14975 3594 4025 18" Dia.Ratings based on 12.3% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.Power Burner, Forced Draft, Light Oil19-S/W-03 2.60 297 84.2 81.6 929 223 258 6" Dia.19-S/W-04 3.60 413 85.2 81.9 1292 310 359 7" Dia.19-S/W-05 4.6 529 85.2 82.5 1654 397 460 8" Dia.19-S/W-06 5.5 644 85.2 82.9 2013 483 560 8" Dia.19-S/W-07 6.5 760 85.2 83.2 2375 570 661 9" Dia.19-S/W-08 7.5 878 85.1 83.4 2738 657 762 10" Dia.19-S/W-09 8.5 992 85.1 83.6 3100 744 863 10" Dia.19-S/W-10 9.5 1107 85.1 83.7 3456 830 963 10" Dia. 28HE Series19-S/W-11 10.4 1223 85.1 83.8 3821 917 1063 10" Dia.Power Burner, Forced Draft, Inter. Ign., Natural Gas19-S/W-12 11.4 1339 85.1 83.9 4213 1011 1164 12" Dia. 28HE-S/W-04 1143 931 83.6 81.4 2908 698 810 10" Dia.Ratings based on 12.5% CO2 and +0.10" water draft at the vent.28HE-S/W-05 1458 1194 83.6 81.9 3733 896 1038 10" Dia.28HE-S/W-06 1773 1458 83.5 82.2 4625 1110 1268 10" Dia.19A Series28HE-S/W-07 2088 1722 83.5 82.5 5542 1330 1497 12" Dia.Power Burner, Forced Draft, Inter. Ign., Natural Gas 28HE-S/W-08 2403 1985 83.5 82.6 6421 1541 1726 12" Dia.19A-S/W-03 375 297 81.6 79.2 929 223 258 7" Dia. 28HE-S/W-09 2718 2249 83.5 82.7 7275 1746 1956 14" Dia.19A-S/W-04 520 413 82.7 79.5 1292 310 359 7" Dia. 28HE-S/W-10 3033 2513 83.5 82.8 8129 1951 2185 14" Dia.19A-S/W-05 725 575 82.1 79.3 1796 431 500 8" Dia. 28HE-S/W-11 3348 2776 83.5 82.9 8979 2155 2414 14" Dia.19A-S/W-06 931 738 81.7 79.3 2308 554 642 8" Dia. 28HE-S/W-12 3663 3040 83.5 83.0 9833 2360 2643 14" Dia.19A-S/W-07 1137 901 81.4 79.2 2817 676 783 9" Dia. 28HE-S/W-13 3978 3304 83.5 83.0 10688 2565 2873 14" Dia.19A-S/W-08 1342 1063 81.3 79.2 3321 797 924 10" Dia. 28HE-S/W-14 4293 3567 83.5 83.1 11538 2769 3102 16" Dia.19A-S/W-09 1548 1226 81.2 79.2 3883 920 1066 10" Dia. 28HE-S/W-15 4608 3831 83.4 83.1 12392 2974 3331 16" Dia.19A-S/W-10 1754 1388 81.1 79.2 4384 1052 1207 10" Dia. 28HE-S/W-16 4923 4095 83.4 83.2 13246 3179 3561 16" Dia.19A-S/W-11 1959 1551 81.1 79.2 4946 1187 1349 12" Dia. 28HE-S/W-17 5238 4358 83.4 83.2 14100 3384 3790 18" Dia.19A-S/W-12 2165 1713 81.0 79.1 5508 1322 1490 12" Dia. 28HE-S/W-18 5553 4622 83.4 83.2 14954 3589 4019 18" Dia.Ratings based on 9.7% CO2 and +0.10" water draft at the vent.Ratings based on 10.4% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.Power Burner, Forced Draft, Light Oil28HE-S/W-04 7.9 931 86.2 83.9 2908 698 810 10" Dia.28HE-S/W-05 10.2 1194 86.2 84.4 3733 896 1038 10" Dia.28HE-S/W-06 12.2 1458 86.1 84.8 4625 1110 1268 10" Dia.28HE-S/W-07 14.4 1722 86.1 85.0 5542 1330 1497 12" Dia.28HE-S/W-08 16.6 1985 86.1 85.2 6421 1541 1726 12" Dia.28HE-S/W-09 18.8 2249 86.1 85.3 7275 1746 1956 14" Dia.28HE-S/W-10 21.0 2513 86.1 85.4 8129 1951 2185 14" Dia.28HE-S/W-11 23.0 2776 86.0 85.5 8979 2155 2414 14" Dia.28HE-S/W-12 25.5 3040 86.0 85.6 9833 2360 2643 14" Dia.28HE-S/W-13 27.5 3304 86.0 85.6 10688 2565 2873 14" Dia.28HE-S/W-14 29.5 3567 86.0 85.7 11538 2769 3102 16" Dia.28HE-S/W-15 32.0 3831 86.0 85.7 12392 2974 3331 16" Dia.28HE-S/W-16 34.0 4095 86.0 85.7 13246 3179 3561 16" Dia.28HE-S/W-17 36.5 4358 86.0 85.8 14100 3384 3790 18" Dia.28HE-S/W-18 38.5 4622 86.0 85.8 14954 3589 4019 18" Dia.Ratings based on 13.4% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.28A SeriesPower Burner, Forced Draft, Inter. Ign., Natural Gas28A-S/W-04 1154 900 81.0 78.0 2813 675 783 10" Dia.28A-S/W-05 1491 1166 81.0 78.2 3646 875 1014 10" Dia.28A-S/W-06 1827 1433 81.0 78.4 4538 1089 1246 10" Dia.28A-S/W-07 2163 1699 81.0 78.5 5458 1310 1477 12" Dia.28A-S/W-08 2499 1965 81.0 78.6 6358 1526 1709 12" Dia.28A-S/W-09 2836 2232 81.0 78.7 7221 1733 1941 14" Dia. 3500A Mills Series28A-S/W-10 3172 2498 81.0 78.8 8079 1939 2172 14" Dia.Power Burner, Natural Draft, Inter. Ign., Natural Gas28A-S/W-11 3508 2764 81.0 78.8 8942 2146 2403 14" Dia. 3500A-*-06 1499 1165 80.7 77.7 3642 874 1013 16x16x1928A-S/W-12 3844 3031 81.0 78.8 9804 2353 2636 14" Dia. 3500A-*-07 1889 1478 80.7 78.2 4696 1127 1285 16x20x2328A-S/W-13 4180 3297 81.0 78.9 10667 2560 2867 14" Dia. 3500A-*-08 2278 1790 80.8 78.6 5771 1385 1557 20x20x2628A-S/W-14 4517 3563 81.0 78.9 11525 2766 3098 16" Dia. 3500A-*-09 2668 2103 80.8 78.8 6804 1633 1829 20x20x30APR 2009 - 48# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)SMITH CAST IRON BOILERSCAST IRONSteam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)3500A Mills SeriesPower Burner, Natural Draft, Inter. Ign., Natural Gas3500A-*-10 3057 2415 80.8 79.0 7813 1875 2100 20x20x333500A-*-11 3447 2727 80.8 79.1 8821 2117 2371 20x24x373500A-*-12 3836 3040 80.8 79.2 9833 2360 2643 20x24x403500A-*-13 4226 3352 80.8 79.3 10842 2602 2915 24x24x443500A-*-14 4615 3665 80.8 79.4 11854 2845 3187 24x24x47Ratings based on 10.0% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G or GO. * Insert S for Steam, Wfor Water <strong>Boilers</strong>.Power Burner, Natural Draft, Light Oil3500A-*-06 10.4 1165 83.2 80.1 3642 874 1013 16x16x193500A-*-07 13.0 1478 83.2 80.6 4696 1127 1285 16x20x233500A-*-08 15.8 1790 83.3 81.0 5771 1385 1557 20x20x263500A-*-09 18.4 2103 83.3 81.2 6804 1633 1829 20x20x303500A-*-10 21.0 2415 83.3 81.4 7813 1875 2100 20x20x333500A-*-11 24.0 2727 83.3 81.6 8821 2117 2371 20x24x373500A-*-12 26.5 3040 83.3 81.7 9833 2360 2643 20x24x403500A-*-13 29.5 3352 83.3 81.8 10842 2602 2915 24x24x443500A-*-14 32.0 3665 83.3 81.9 11854 2845 3187 24x24x47Ratings based on 13.0% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G or GO. * Insert S for Steam, Wfor Water <strong>Boilers</strong>.NameplateInputGrossOutput(MBh)BoilerGas OilModel(MBh) (gph)* Insert S for Steam, W for Water <strong>Boilers</strong>.CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)Power Burner, Natural Draft, Inter. Ign., Natural Gas4500A-*-10 3920 3080 82.1 78.6 9963 2391 2678 20x24x304500A-*-11 4404 3467 81.8 78.7 11217 2692 3015 24x24x374500A-*-12 4888 3853 81.6 78.8 12463 2991 3350 24x24x444500A-*-13 5372 4240 81.4 78.9 13717 3292 3687 24x28x514500A-*-14 5856 4627 81.3 79.0 14967 3592 4023 24x28x584500A-*-15 6341 5014 81.1 79.1 16221 3893 4360 24x28x654500A-*-16 6825 5400 81.0 79.1 17471 4193 4696 28x28x724500A-*-17 7309 5787 80.9 79.2 18721 4493 5032 28x28x794500A-*-18 7793 6174 80.9 79.2 19971 4793 5369 28x28x864500A-*-19 8277 6560 80.8 79.3 21221 5093 5704 30x30x934500A-*-20 8761 6947 80.7 79.3 22475 5394 6041 30x30x1004500A-*-21 9246 7334 80.7 79.3 23725 5694 6377 30x36x1074500A-*-22 9730 7720 80.6 79.3 24975 5994 6713 30x36x114Ratings based on 9.7% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G, LO, and GLO. * Insert S forSteam, W for Water <strong>Boilers</strong>.Power Burner, Natural Draft, Light Oil4500A-*-10 27.0 3080 84.6 81.0 9963 2391 2678 20x24x304500A-*-11 30.5 3467 84.3 81.2 11217 2692 3015 24x24x374500A-*-12 34.0 3853 84.1 81.3 12463 2991 3350 24x24x444500A-*-13 37.0 4240 83.9 81.4 13717 3292 3687 24x28x514500A-*-14 40.5 4627 83.8 81.4 14967 3592 4023 24x28x584500A-*-15 44.0 5014 83.7 81.5 16221 3893 4360 24x28x654500A-*-16 47.5 5400 83.5 81.6 17471 4193 4696 28x28x724500A-*-17 51.0 5787 83.5 81.6 18721 4493 5032 28x28x794500A-*-18 54.0 6174 83.4 81.7 19971 4793 5369 28x28x864500A-*-19 57.0 6560 83.3 81.7 21221 5093 5704 30x30x934500A-*-20 61.0 6947 83.2 81.7 22475 5394 6041 30x30x1004500A-*-21 64.0 7334 83.2 81.8 23725 5694 6377 30x36x1074500A-*-22 67.0 7720 83.2 81.8 24975 5994 6713 30x36x114Ratings based on 12.5% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G, LO, and GLO. * Insert S forSteam, W for Water <strong>Boilers</strong>.350A Mills SeriesPower Burner, Natural Draft, Inter. Ign., Natural Gas350A-*-06 1290 1001 80.9 77.6 3129 751 870 16x16x17350A-*-07 1585 1235 81.0 78.0 3858 926 1074 16x16x20350A-*-08 1879 1470 81.0 78.2 4667 1120 1278 16x20x23350A-*-09 2174 1705 81.0 78.4 5483 1316 1483 16x20x26350A-*-10 2469 1939 81.0 78.6 6271 1505 1686 20x20x29350A-*-11 2763 2174 81.0 78.7 7033 1688 1890 20x20x32350A-*-12 3057 2474 81.0 78.8 7792 1870 2095 20x20x356500A Mills Series350A-*-13 3352 2643 81.0 78.9 8550 2052 2298 20x24x38Power Burner, Natural Draft, Inter. Ign., Natural Gas350A-*-14 3646 2878 81.0 78.9 9308 2234 2503 20x24x416500A-*-15 8936 7194 81.9 80.5 23271 5585 6256 30x30x55* Insert S for Steam, W for Water <strong>Boilers</strong>.6500A-*-16 9805 7872 81.7 80.3 25467 6112 6845 30x36x61Power Burner, Natural Draft, Light Oil6500A-*-17 10674 8550 81.6 80.1 27658 6638 7435 30x36x66350A-*-06 8.9 1001 83.4 80.0 3129 751 870 16x16x17 6500A-*-18 11543 9228 81.4 79.9 29854 7165 8024 30x36x72350A-*-07 11.0 1235 83.5 80.4 3858 926 1074 16x16x20 6500A-*-19 12412 9906 81.3 79.8 32046 7691 8614 36x36x77350A-*-08 13.0 1470 83.5 80.6 4667 1120 1278 16x20x23 6500A-*-20 13281 10584 81.3 79.7 34238 8217 9203 36x36x83350A-*-09 15.0 1705 83.5 80.8 5483 1316 1483 16x20x26 6500A-*-21 14150 11262 81.2 79.6 36433 8744 9793 36x36x88350A-*-10 17.2 1939 83.5 81.0 6271 1505 1686 20x20x29 6500A-*-22 15019 11940 81.1 79.5 38625 9270 10383 36x36x94350A-*-11 19.2 2174 83.5 81.1 7033 1688 1890 20x20x32 6500A-*-23 15888 12618 81.1 79.4 40821 9797 10972 36x42x99350A-*-12 21.0 2474 83.5 81.2 7792 1870 2095 20x20x35 6500A-*-24 16758 13297 81.0 79.3 43017 10324 11563 36x42x105350A-*-13 23.0 2643 83.5 81.3 8550 2052 2298 20x24x38 6500A-*-25 17627 13975 81.0 79.3 45208 10850 12152 36x42x110350A-*-14 25.5 2878 83.5 81.4 9308 2234 2503 20x24x41 Ratings based on 12.4% CO2 and -0.02" water draft.Ratings based on 13.0% CO2 and -0.02" water draft.* Insert S for Steam, W for Water <strong>Boilers</strong>.* Insert S for Steam, W for Water <strong>Boilers</strong>.6500A Series4500A Mills SeriesPower Burner, Natural Draft, Heavy OilPower Burner, Natural Draft, Heavy Oil6500A-*-15 58.0 7194 84.4 83.0 23271 5585 6256 30x30x554500A-*-10 25.0 3045 84.4 81.2 9850 2364 2648 20x24x30 6500A-*-16 63.0 7872 84.2 82.8 25467 6112 6845 30x36x614500A-*-11 28.0 3435 84.3 81.5 11113 2667 2987 24x24x37 6500A-*-17 69.0 8550 84.1 82.6 27658 6638 7435 30x36x664500A-*-12 31.0 3825 84.3 81.8 12375 2970 3326 24x24x44 6500A-*-18 75.0 9228 84.0 82.4 29854 7165 8024 30x36x724500A-*-13 34.5 4214 84.3 81.9 13633 3272 3664 24x28x51 6500A-*-19 80.0 9906 83.9 82.3 32046 7691 8614 36x36x774500A-*-14 37.5 4604 84.2 82.1 14896 3575 4003 24x28x58 6500A-*-20 86.0 10584 83.8 82.2 34238 8217 9203 36x36x834500A-*-15 40.5 4994 84.2 82.3 16154 3877 4343 24x28x65 6500A-*-21 92.0 11262 83.7 82.1 36433 8744 9793 36x36x884500A-*-16 43.5 5384 84.2 82.4 17417 4180 4682 28x28x72 6500A-*-22 97.0 11940 83.6 82.0 38625 9270 10383 36x36x944500A-*-17 46.5 5774 84.2 82.5 18679 4483 5021 28x28x79 6500A-*-23 103.0 12618 83.6 81.9 40821 9797 10972 36x42x994500A-*-18 50.0 6163 84.2 82.6 19938 4785 5359 28x28x86 6500A-*-24 108.0 13297 83.5 81.8 43017 10324 11563 36x42x1054500A-*-19 53.0 6553 84.2 82.7 21200 5088 5698 30x30x93 6500A-*-25 114.0 13975 83.5 81.7 45208 10850 12152 36x42x1104500A-*-20 56.0 6943 84.1 82.7 22463 5391 6037 30x30x100 Ratings based on 12.4% CO2 and -0.02" water draft.4500A-*-21 59.0 7333 84.1 82.8 23721 5693 6377 30x36x107 * Insert S for Steam, W for Water <strong>Boilers</strong>.4500A-*-22 62.0 7723 84.1 82.8 24983 5996 6716 30x36x114Power Burner, Natural Draft, Light OilRatings based on 12.3% CO2 and -0.01" water draft.6500-*-15 62.0 7194 84.4 83.0 23271 5585 6256 30x30x55APR 2009 - 49# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)SMITH CAST IRON BOILERSCAST IRONSteam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)6500A SeriesPower Burner, Natural Draft, Light Oil6500-*-16 68.0 7872 84.2 83.8 25467 6112 6845 30x36x616500-*-17 74.0 8550 84.1 83.6 27658 6638 7435 30x36x666500-*-18 80.0 9228 84.0 83.4 29854 7165 8024 30x36x726500-*-19 86.0 9906 83.9 82.3 32046 7691 8614 36x36x776500-*-20 92.0 10585 83.8 82.2 34242 8218 9204 36x36x836500-*-21 98.0 11263 83.7 82.1 36438 8745 9794 36x36x886500-*-22 104.0 11941 83.6 82.0 38629 9271 10383 36x36x946500-*-23 110.0 12619 83.6 81.9 40821 9797 10973 36x42x996500-*-24 116.0 13297 83.5 81.8 43017 10324 11563 36x42x1056500-*-25 122.0 13975 83.5 81.7 45208 10850 12152 36x42x110Ratings based on 12.4% CO2 and -0.02" water draft.* Insert S for Steam, W for Water <strong>Boilers</strong>.650A Mills SeriesPower Burner, Natural Draft, Heavy Oil650A-*-15 50.0 6247 84.7 83.3 20208 4850 5432 28x28x47650A-*-16 53.0 6672 84.7 83.3 21583 5180 5802 28x28x50650A-*-17 57.0 7098 84.8 83.3 22963 5511 6172 30x30x52650A-*-18 60.0 7523 84.8 83.3 24338 5841 6542 30x30x54650A-*-19 64.0 7949 84.9 83.3 25717 6172 6912 30x36x56650A-*-20 67.0 8374 84.9 83.3 27092 6502 7282 30x36x58650A-*-21 70.0 8799 85.0 83.3 28467 6832 7651 30x36x61650A-*-22 74.0 9225 85.0 83.3 29842 7162 8022 30x36x64650A-*-23 77.0 9650 85.0 83.3 31217 7492 8391 36x36x67650A-*-24 81.0 10076 85.0 83.3 32596 7823 8762 36x36x69650A-*-25 84.0 10501 85.1 83.3 33971 8153 9131 36x36x71Ratings based on 12.4% CO2 and -0.02" water draft.* Insert S for Steam, W for Water <strong>Boilers</strong>.Power Burner, Natural Draft, Inter. Ign., Natural Gas650A-*-15 7732 6247 82.1 80.8 20208 4850 5432 28x28x47650A-*-16 8258 6672 82.2 80.8 21583 5180 5802 28x28x50650A-*-17 8784 7098 82.3 80.8 22963 5511 6172 30x30x52650A-*-18 9309 7523 82.3 80.8 24338 5841 6542 30x30x54650A-*-19 9835 7949 82.3 80.8 25717 6172 6912 30x36x56650A-*-20 10361 8374 82.4 80.8 27092 6502 7282 30x36x58650A-*-21 10887 8799 82.4 80.8 28467 6832 7651 30x36x61650A-*-22 11412 9225 82.4 80.8 29842 7162 8022 30x36x64650A-*-23 11938 9650 82.5 80.8 31217 7492 8391 36x36x67650A-*-24 12464 10076 82.5 80.8 32596 7823 8762 36x36x69650A-*-25 12990 10501 82.6 80.8 33971 8153 9131 36x36x71* Insert S for Steam, W for Water <strong>Boilers</strong>.#G250 SeriesPower Burner, Atmospheric, Inter. Ign., Natural GasGB250-S-7-INT 300 240 80.0 75.8 750 180GB250-S-8-INT 350 280 80.0 75.8 875 210GB250-S-9-INT 400 320 80.0 75.8 1000 240Ratings also approved with the suffix D for Stack DamperBoilerModelNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)M450A Mills SeriesPower Burner, Natural Draft, Heavy OilM450A-*-10 19.6 2449 85.9 83.5 7921 1901 2130 20x20x29M450A-*-11 22.0 2733 85.9 83.7 8842 2122 2377 20x24x33M450A-*-12 24.0 3016 86.0 83.9 9758 2342 2623 20x24x37M450A-*-13 26.0 3300 86.0 84.0 10675 2562 2870 24x24x40M450A-*-14 28.5 3583 86.0 84.1 11592 2782 3116 24x24x44M450A-*-15 30.5 3867 86.0 84.2 12508 3002 3363 24x24x47M450A-*-16 33.0 4151 86.0 84.3 13429 3223 3610 24x28x53M450A-*-17 35.0 4434 86.0 84.3 14346 3443 3856 24x28x59M450A-*-18 37.5 4718 86.1 84.4 15263 3663 4103 24x28x65M450A-*-19 39.5 5001 86.1 84.5 16179 3883 4349 28x28x71M450A-*-20 41.5 5285 86.1 84.5 17096 4103 4596 28x28x77M450A-*-21 44.0 5568 86.1 84.6 18013 4323 4842 28x28x82M450A-*-22 46.0 5852 86.1 84.6 18929 4543 5089 28x28x88Ratings based on 12.5% CO2 and -0.02" water draft.* Insert S for Steam, W for Water <strong>Boilers</strong>.Power Burner, Natural Draft, Inter. Ign., Natural GasM450A-*-10 3031 2449 83.7 80.8 7921 1901 2130 20x20x29M450A-*-11 3380 2733 83.4 80.9 8842 2122 2377 20x24x33M450A-*-12 3729 3016 83.2 80.9 9758 2342 2623 20x24x37M450A-*-13 4077 3300 83.0 80.9 10675 2562 2870 24x24x40M450A-*-14 4426 3583 82.9 81.0 11592 2782 3116 24x24x44M450A-*-15 4775 3867 82.7 81.0 12508 3002 3363 24x24x47M450A-*-16 5124 4151 82.6 81.0 13429 3223 3610 24x28x53M450A-*-17 5473 4434 82.5 81.0 14346 3443 3856 24x28x59M450A-*-18 5821 4718 82.4 81.0 15263 3663 4103 24x28x65M450A-*-19 6170 5001 82.4 81.1 16179 3883 4349 28x28x71M450A-*-20 6519 5285 82.3 81.1 17096 4103 4596 28x28x77M450A-*-21 6868 5568 82.2 81.1 18013 4323 4842 28x28x82M450A-*-22 7216 5852 82.2 81.1 18929 4543 5089 28x28x88Ratings based on 9.5% CO2 and -0.02" water draft.* Insert S for Steam, W for Water <strong>Boilers</strong>.Power Burner, Natural Draft, Light OilM450A-*-10 21.0 2449 86.3 83.3 7921 1901 2130 20x20x29M450A-*-11 23.5 2733 86.0 83.4 8842 2122 2377 20x24x33M450A-*-12 26.0 3016 85.8 83.4 9758 2342 2623 20x24x37M450A-*-13 28.5 3300 85.6 83.4 10675 2562 2870 24x24x40M450A-*-14 30.5 3583 85.4 83.5 11592 2782 3116 24x24x44M450A-*-15 33.0 3867 85.3 83.5 12508 3002 3363 24x24x47M450A-*-16 35.5 4151 85.2 83.5 13429 3223 3610 24x28x53M450A-*-17 38.0 4434 85.1 83.5 14346 3443 3856 24x28x59M450A-*-18 40.5 4718 85.0 83.5 15263 3663 4103 24x28x65M450A-*-19 43.0 5001 84.9 83.6 16179 3883 4349 28x28x71M450A-*-20 45.0 5285 84.8 83.6 17096 4103 4596 28x28x77M450A-*-21 47.5 5568 84.8 83.6 18013 4323 4842 28x28x82M450A-*-22 50.0 5852 84.8 83.6 18929 4543 5089 28x28x88Ratings based on 12.5% CO2 and -0.02" water draft.* Insert S for Steam, W for Water <strong>Boilers</strong>.A.O. SMITH WATER PRODUCTS CO.COPPERPower Burner, Atmospheric, Inter. Ign., Propane GasPGB250-S-7-INT 300 240 80.0 75.8 750 180#BurkayPGB250-S-8-INT 350 280 80.0 75.8 875 210Atmospheric, Inter. Ign., Natural or Propane GasPGB250-S-9-INT 360 288 80.0 75.8 900 216HW-300 300 247 80.0 82.0215Ratings also approved with the suffix D for Stack DamperPower Burner, Atmospheric, Standing Pilot, Natural GasHW-399HW-42039942032334480.080.082.082.0281299GB250-S-7-CON 300 240 80.0 75.8 750 180HW-520 520 429 80.0 82.0373GB250-S-8-CON 350 280 80.0 75.8 875 210HW-670 660 544 80.0 80.0473GB250-S-9-CON 400 320 80.0 75.8 1000 240#DuramaxRatings also approved with the suffix D for Stack DamperAtmospheric, Inter. Ign., Natural GasPower Burner, Atmospheric, Standing Pilot, Propane GasDB-720 720 583 80.0 81.0507PGB250-S-7-CON 300 240 80.0 75.8 750 180DB-840 840 680 80.0 81.0591PGB250-S-8-CON 350 280 80.0 75.8 875 210DB-960 960 778 80.0 81.0677PGB250-S-9-CON 360 288 80.0 75.8 900 216DB-1080 1080 886 80.0 82.0770Ratings also approved with the suffix D for Stack DamperAPR 2009 - 50# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)A.O. SMITH WATER PRODUCTS CO.COPPERCOMMERCIAL BOILERSVentSize(LxWxH)NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)EVCA2000B**-*A* 2000 1900 92.5 95.01652 6" Dia.EVCA2000B**-*B* 2000 1900 92.5 95.01652 6" Dia.EVCA2000B**-*C* 2000 1900 92.5 95.01652 6" Dia.EVCA2000B**-*D* 2000 1900 92.5 95.01652 6" Dia.#DuramaxEVCA2000B**-*E* 2000 1900 92.5 95.01652 6" Dia.Atmospheric, Inter. Ign., Natural GasEVCA2000B**-*F* 2000 1900 92.5 95.01652 6" Dia.DB-1210 1210 992 80.0 82.0863Ratings based on 11.0% CO2 and +0.10" water draft at the vent.DB-1350 1350 1107 80.0 82.0963DB-1480 1480 1184 80.0 80.01030DB-1610 1610 1288 80.0 80.01120THERMO-DYNAMICS BOILER CO.DB-1810 1810 1448 80.0 80.01259 STEEL#Genesis 400HT SeriesModulating, Induced Draft, Inter. Ign., Natural or Propane GasForced Draft, Light OilGB-300 300 251 82.0 83.0218 5" Dia. HT-225 2.25 264 85.6 83.7230 8" Dia.GB-400 400 335 82.0 83.0291 6" Dia. HT-250 2.50 291 85.2 83.4253 8" Dia.GB-500 500 419 82.0 83.0364 6" Dia. HT-275 2.75 319 84.9 82.9277 8" Dia.GB-650 650 544 82.0 83.0473 8" Dia. Ratings based on 13.2% CO2 and -0.02" water draft at the vent.GB-750 750 628 82.0 83.0546 8" Dia.GB-1000 990 832 82.0 83.0723 10" Dia.GB-1300 1300 1092 82.0 83.0950 12" Dia.TRIANGLE TUBEGB-1500 1500 1260 82.0 83.01096 12" Dia. STAINLESS STEELGB-1850 1850 1554 82.0 83.01351 14" Dia.GB-2100 2100 1764 82.0 83.01534 14" Dia.PrestigeGB-2500 2500 2092 82.0 83.01819 16" Dia. Power Burner, Modulating, Condensing, Pressure Fired, Inter. Ign., Natural orPropane Gas#Genesis 400 OutdoorSolo 399 399 379 94.1 95.1330 4" Dia.Modulating, Outdoor, Induced Draft, Inter. Ign., Natural or Propane Gas Ratings based on 9.0% CO2 and 0" water draft.GBO-300 300 251 82.0 83.0218 5" Dia.GBO-400 400 335 82.0 83.0291 6" Dia.UTICA BOILERS, ECR INTERNATIONAL, INC.GBO-500 500 419 82.0 83.0364 6" Dia.GBO-650 650 544 82.0 83.0473 8" Dia. CAST IRONGBO-750 750 628 82.0 83.0546 8" Dia.#J-C SeriesGBO-1000 990 832 82.0 83.0723 10" Dia.Atmospheric, Inter. Ign., Natural GasGBO-1300 1300 1092 82.0 83.0950 12" Dia.JC-300 300 240 80.0 750 180 209GBO-1500 1500 1260 82.0 83.01096 12" Dia.JC-400 400 320 80.0 1000 240 278GBO-1850 1850 1554 82.0 83.01351 14" Dia.JC-500 500 400 80.0 1250 300 348GBO-2100 2100 1764 82.0 83.01534 14" Dia.JC-600 600 480 80.0 1500 360 417GBO-2500 2490 2092 82.0 83.01819 16" Dia.JC-700 700 560 80.0 1750 420 487#VF Series - VBsModulating, Induced Draft, Inter. Ign., Natural or Propane GasJC-800JC-90080090064072080.080.020002250480540557626VB 500 500 413 84.0359 8" Dia. JC-1000 1000 800 80.0 2500 600 696VB 750 750 619 84.0538 8" Dia. JC-1100 1100 880 80.0 2750 660 765VB 1,000 1000 830 84.0722 8" Dia. JC-1200 1200 960 80.0 3000 720 835JC-1300 1300 1040 80.0 3250 780 904THERMAL SOLUTIONS PRODUCTS, LLCJC-1400 1400 1120 80.0 3500 840 974JC-1500 1500 1200 80.0 3750 900 1043STAINLESS STEELJC1600 1600 1280 80.0 4008 962 1113JC-1700 1700 1360 80.0 4283 1028 1183Evolution CondensingJC-1800 1800 1440 80.0 4563 1095 1252Modulating, Condensing, Forced Draft, Inter. Ign., Natural or Propane Gas JC-1900 1900 1520 80.0 4838 1161 1322EVCA0750B**-*A* 750 699 91.3 93.2608 4" Dia. JC-2000 2000 1600 80.0 5117 1228 1391EVCA0750B**-*B* 750 699 91.3 93.2608 4" Dia. JC-2100 2100 1680 80.0 5392 1294 1461EVCA0750B**-*C* 750 699 91.3 93.2608 4" Dia. JC-2200 2200 1760 80.0 5671 1361 1530EVCA0750B**-*D* 750 699 91.3 93.2608 4" Dia. JC-2300 2300 1840 80.0 5942 1426 1600EVCA0750B**-*E* 750 699 91.3 93.2608 4" Dia. JC-2400 2400 1920 80.0 6213 1491 1670EVCA0750B**-*F* 750 699 91.3 93.2608 4" Dia. JC-2500 2500 2000 80.0 6471 1553 1739EVC1000B**-*B* 1000 939 91.8 93.9817 6" Dia. JC-2600 2600 2080 80.0 6729 1615 1809EVCA1000B**-*A* 1000 939 91.8 93.9817 6" Dia. JC-2700 2700 2160 80.0 6988 1677 1878EVCA1000B**-*C* 1000 939 91.8 93.9817 6" Dia. JC-2800 2800 2240 80.0 7246 1739 1948EVCA1000B**-*D* 1000 939 91.8 93.9817 6" Dia. JC-2900 2900 2320 80.0 7504 1801 2017EVCA1000B**-*E* 1000 939 91.8 93.9817 6" Dia. JC-3000 3000 2400 80.0 7763 1863 2087EVCA1000B**-*F* 1000 939 91.8 93.9817 6" Dia.EVCA1500B**-*A* 1500 1420 92.3 94.71235 6" Dia. Starfire Steam SeriesEVCA1500B**-*B* 1500 1420 92.3 94.71235 6" Dia.Natural Draft, Light OilEVCA1500B**-*C* 1500 1420 92.3 94.71235 6" Dia. SFH6225 2.25 251 83.3 79.7 783 188 218 8x12x15EVCA1500B**-*D* 1500 1420 92.3 94.71235 6" Dia. SFH7275 2.75 307 83.3 79.7 958 230 267 8x12x15EVCA1500B**-*E* 1500 1420 92.3 94.71235 6" Dia. Ratings based on 13.0% CO2 and -0.02" water draft.EVCA1500B**-*F* 1500 1420 92.3 94.71235 6" Dia.Starfire Water SeriesAPR 2009 - 51# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


COMMERCIAL BOILERSBoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)UTICA BOILERS, ECR INTERNATIONAL, INC.CAST IRONVentSize(LxWxH)Starfire Water SeriesNatural Draft, Light OilSFH6225W 2.25 255 83.3 80.9218 8x12x15SFH7275W 2.75 312 83.3 80.9267 8x12x15Ratings based on 13.0% CO2 and -0.01" water draft.NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)CT3-17 638 626 98.3 98.1544 8" Dia.CT3-22 846 827 97.8 97.7719 8" Dia.CT3-28 1071 1044 97.4 97.4908 8" Dia.CT3-37 1389 1350 97.2 97.21174 10" Dia.CT3-46 1726 1675 97.1 97.11457 10" Dia.CT3-57 2160 2094 96.9 96.91821 10" Dia.CT3-72 2702 2616 96.8 96.82275 12" Dia.CT3-89 3361 3252 96.7 96.72828 12" Dia.Ratings based on 10.0% CO2 and 0" water draft at the vent.VIESSMANN MANUFACTURING COMPANY, INC.WEIL-MCLAINCAST IRONALUMINUM#VITOGAS 100, GS10 SeriesUltra Series 3Atmospheric, Inter. Ign., Natural or Propane Gas Modulating, Condensing, Induced Draft, Inter. Ign., Natural or Propane GasGS10-72 300 257 85.6223ULTRA 310 310 2.05 288 93.3 92.9250 4" Dia.GS10-84 340 291 85.6253ULTRA 399 399 364 91.7 91.3317 4" Dia.GS10-96 380 325 85.6283CAST IRON#VITOGAS 50-RS80 Series 1Atmospheric, Inter. Ign., Natural or Propane GasRS-08 550 468 85.0407Forced Draft, Light OilRS-11 800 680 85.0591380 2.40 278 85.3 82.7 867 208 242 8" Dia.RS-14 1050 893 85.0776480 3.40 396 85.5 83.2 1238 297 344 8" Dia.580 4.45 515 85.1 83.1 1608 386 448 8" Dia.Vitorond 200 GasPower Burner, Two-Stage, Pressure Fired, Inter. Ign., Natural or Propane Gas6807805.56.563475384.984.783.183.1198323544765655516558" Dia.10" Dia.VD2-125 508 433 84.7 85.2377 8" Dia. 880 7.5 872 84.6 83.0 2725 654 758 10" Dia.VD2-160 650 553 84.8 85.1481 8" Dia. 980 8.5 991 84.5 83.0 3096 743 862 10" Dia.VD2-195 792 672 84.8 84.8584 8" Dia. 1090 9.6 1110 84.4 83.0 3471 833 965 10" Dia.VD2-230 934 792 84.8 84.8689 10" Dia. 1180 10.6 1229 84.4 83.0 3842 922 1069 10" Dia.VD2-270 1096 928 84.8 84.7807 10" Dia. 1280 11.6 1348 84.3 83.0 4242 1018 1172 12" Dia.VD2-320 1300 1110 85.5 85.4965 12" Dia. Ratings based on 13.0% CO2 and +0.10" water draft at the vent.VD2-380 1544 1319 85.4 85.41147 12" Dia.Power Burner, Forced Draft, Inter. Ign., Natural GasVD2-440 1787 1526 85.4 85.41327 12" Dia. 380 346 278 82.7 80.2 867 208 242 8" Dia.VD2-500 2031 1732 85.3 85.31506 14" Dia. 480 491 396 82.9 80.7 1238 297 344 8" Dia.VD2-560 2275 1941 85.2 85.31688 14" Dia. 580 639 515 82.6 80.6 1608 386 448 8" Dia.VD2-630 2559 2183 85.1 85.31898 14" Dia. 680 787 634 82.3 80.6 1983 476 551 8" Dia.VD2-700 2843 2425 85.1 85.32109 16" Dia. 780 935 753 82.2 80.6 2354 565 655 10" Dia.VD2-780 3168 2699 85.0 85.22347 16" Dia. 880 1082 872 82.0 80.6 2725 654 758 10" Dia.VD2-860 3493 2976 84.9 85.22588 16" Dia. 980 1230 991 82.0 80.5 3096 743 862 10" Dia.VD2-950 3680 3135 84.8 85.22726 18" Dia. 1090 1378 1110 81.9 80.5 3471 833 965 10" Dia.VD2-1080 4387 3738 84.6 85.23250 18" Dia. 1180 1526 1229 81.8 80.5 3842 922 1069 10" Dia.Ratings based on 11.0% CO2 and -0.03" water draft.1280 1674 1348 81.8 80.5 4242 1018 1172 12" Dia.Vitorond 200-Oil88 Series 1Power Burner, Two-Stage, Pressure Fired, Light OilForced Draft, Light OilVD2-125 3.50 433 87.7 87.9377 8" Dia. 488R 6.9 794 84.4 82.2 2483 596 690 10" Dia.VD2-160 4.50 553 87.3 87.6481 8" Dia. 488 7.0 810 84.4 82.2 2533 608 704 10" Dia.VD2-195 5.5 672 87.3 87.4584 8" Dia. 588 9.4 1084 84.1 82.2 3388 813 943 10" Dia.VD2-230 6.5 792 87.3 87.3689 10" Dia. 688 11.8 1358 83.9 82.3 4275 1026 1181 10" Dia.VD2-270 7.6 928 87.3 87.2807 10" Dia. 788 14.2 1632 83.8 82.3 5225 1254 1419 12" Dia.VD2-320 9.0 1110 88.1 88.0965 12" Dia. 888 16.6 1904 83.7 82.3 6154 1477 1656 12" Dia.VD2-380 10.6 1319 88.0 88.01147 12" Dia. 988R 17.2 1991 83.7 82.3 6442 1546 1731 14" Dia.VD2-440 12.4 1526 88.0 88.01327 12" Dia. 988 18.8 2176 83.7 82.3 7038 1689 1892 14" Dia.VD2-500 14.0 1732 87.9 88.01506 14" Dia. 1088R 20.0 2304 83.6 82.3 7454 1789 2003 14" Dia.VD2-560 15.8 1941 87.8 88.01688 14" Dia. 1088 21.5 2452 83.6 82.3 7933 1904 2132 14" Dia.VD2-630 17.8 2183 87.8 87.91898 14" Dia. 1188 23.5 2724 83.6 82.3 8813 2115 2369 14" Dia.VD2-700 19.6 2425 87.7 87.92109 16" Dia. 1288 26.0 3000 83.5 82.3 9704 2329 2609 14" Dia.VD2-780 22.0 2699 87.6 87.92347 16" Dia. 1388 28.5 3270 83.5 82.3 10579 2539 2843 14" Dia.VD2-860 24.2 2976 87.5 87.92588 16" Dia. 1488 31.0 3550 83.5 82.3 11483 2756 3087 16" Dia.VD2-950 27.0 3135 87.4 87.82726 18" Dia. 1588 33.0 3820 83.5 82.3 12358 2966 3322 16" Dia.VD2-1080 30.4 3738 87.3 87.83250 18" Dia. 1688R 34.5 3980 83.5 82.3 12875 3090 3461 16" Dia.Ratings based on 13.1% CO2 and -0.03" water draft.STAINLESS STEEL1688178835.538.04090437083.583.482.382.31322914138317533933557380016" Dia.18" Dia.Vitocrossal 300Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural orPropane Gas1888 40.5 4640 83.4 82.3 15008 3602 4035 18" Dia.Ratings based on 12.5% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL,PG, PL, and PGL and suffix WF and SF.APR 2009 - 52# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)NameplateInputGrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsVentSize(LxWxH)BoilerGas OilSteam Steam WaterModel(MBh) (gph)(sqft) (MBh) (MBh)1788 38.2 4570 85.9 85.7 14784 3548 3974 18" Dia.WEIL-MCLAIN1888 40.6 4857 85.9 85.7 15712 3771 4223 18" Dia.CAST IRONRatings based on 12.5% CO2 and +0.10" water draft at the vent.Also approved with prefix BL, BGL, ABL, ABGL, PL, and PGL and suffix WF and88 Series 1SFPower Burner, Forced Draft, Inter. Ign., Natural Gas488R 996 794 81.9 79.7 2483 596 690 10" Dia. 94 Series 3488 1010 810 81.9 79.7 2533 608 704 10" Dia.Forced Draft, Heavy Oil588 1357 1084 81.6 79.8 3388 813 943 10" Dia. 894 16.6 2028 83.6 81.0 6563 1575 1763 14" Dia.688 1703 1358 81.4 79.8 4275 1026 1181 10" Dia. 994 19.0 2320 83.6 81.1 7504 1801 2017 14" Dia.788 2049 1632 81.3 79.8 5225 1254 1419 12" Dia. 1094 21.5 2612 83.6 81.1 8450 2028 2271 16" Dia.888 2396 1904 81.2 79.8 6154 1477 1656 12" Dia. 1194 24.0 2904 83.6 81.2 9396 2255 2525 16" Dia.988R 2482 1991 81.2 79.8 6442 1546 1731 14" Dia. 1294 26.0 3190 83.6 81.3 10321 2477 2774 16" Dia.988 2713 2176 81.2 79.8 7038 1689 1892 14" Dia. 1394 28.5 3480 83.6 81.3 11258 2702 3026 18" Dia.1088R 2887 2304 81.1 79.8 7454 1789 2003 14" Dia. 1494 31.0 3770 83.6 81.4 12196 2927 3278 18" Dia.1088 3103 2452 81.1 79.8 7933 1904 2132 14" Dia. 1594 33.0 4070 83.6 81.4 13167 3160 3539 18" Dia.1188 3392 2724 81.1 79.8 8813 2115 2369 14" Dia. 1694 35.5 4360 83.6 81.5 14104 3385 3791 18" Dia.1288 3753 3000 81.0 79.8 9704 2329 2609 14" Dia. 1794 38.0 4650 83.6 81.6 15042 3610 4043 20" Dia.1388 4113 3270 81.0 79.9 10579 2539 2843 14" Dia. 1894 40.5 4940 83.6 81.6 15979 3835 4296 20" Dia.1488 4474 3550 81.0 79.9 11483 2756 3087 16" Dia. 1994 42.5 5230 83.6 81.7 16921 4061 4548 20" Dia.1588 4763 3820 81.0 79.9 12358 2966 3322 16" Dia. 2094 45.0 5520 83.6 81.8 17858 4286 4800 20" Dia.1688R 4979 3980 81.0 79.9 12875 3090 3461 16" Dia. Ratings based on 12.3% CO2 and +0.10" water draft at the vent.1688 5124 4090 81.0 79.9 13229 3175 3557 16" Dia. Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL,1788 5485 4370 80.9 79.9 14138 3393 3800 18" Dia. PG, PL, and PGL and suffix WF and SF.1888 5845 4640 80.9 79.9 15008 3602 4035 18" Dia.Forced Draft, Light OilRatings based on 9.5% CO2 and +0.10" water draft at the vent.894 17.6 2028 83.7 82.7 6563 1575 1763 14" Dia.994 20.0 2320 83.8 82.8 7504 1801 2017 14" Dia.88 Series 2 gas1094 22.5 2612 83.8 82.8 8450 2028 2271 16" Dia.Power Burner, Forced Draft, Inter. Ign., Natural Gas1194 25.0 2904 83.9 82.8 9396 2255 2525 16" Dia.488R 996 827 84.8 83.1 2585 620 719 10" Dia.1294 27.5 3190 83.9 82.8 10321 2477 2774 16" Dia.488 1010 839 84.8 83.1 2623 629 730 10" Dia.1394 30.0 3480 83.9 82.8 11258 2702 3026 18" Dia.588 1356 1126 84.4 83.1 3520 845 979 10" Dia.1494 32.5 3770 83.9 82.9 12196 2927 3278 18" Dia.688 1701 1413 84.1 83.1 4467 1072 1229 10" Dia.1594 35.0 4070 84.0 82.9 13167 3160 3539 18" Dia.788 2046 1700 83.9 83.1 5463 1311 1478 12" Dia.1694 37.5 4360 84.0 82.9 14104 3385 3791 18" Dia.888 2382 1987 83.7 83.1 6428 1543 1728 12" Dia.1794 40.0 4650 84.0 82.9 15042 3610 4043 20" Dia.988R 2482 2062 83.7 83.1 6671 1601 1793 14" Dia.1894 42.5 4940 84.0 82.9 15979 3835 4296 20" Dia.988 2737 2274 83.7 83.1 7356 1766 1977 14" Dia.1994 45.0 5230 84.0 83.0 16921 4061 4548 20" Dia.1088R 2887 2399 83.6 83.1 7761 1863 2086 14" Dia.2094 47.5 5520 84.0 83.0 17858 4286 4800 20" Dia.1088 3082 2561 83.6 83.1 8285 1988 2227 14" Dia.2194 50.0 5810 84.0 83.0 18796 4511 5052 20" Dia.1188 3428 2848 83.5 83.1 9213 2211 2477 14" Dia.2294 53.0 6100 84.0 83.0 19733 4736 5304 22" Dia.1288 3773 3135 83.5 83.1 10142 2434 2726 14" Dia.2394 55.0 6390 84.1 83.0 20671 4961 5557 22" Dia.1388 4119 3422 83.4 83.1 11070 2657 2976 14" Dia.2494 58.0 6680 84.1 83.0 21608 5186 5809 22" Dia.1488 4464 3709 83.4 83.1 11999 2880 3225 16" Dia.2594 60.0 6970 84.1 83.0 22546 5411 6061 22" Dia.1588 4809 3996 83.3 83.1 12927 3102 3475 16" Dia.Ratings based on 12.3% CO2 and +0.10" water draft at the vent.1688R 4979 4137 83.3 83.1 13383 3212 3597 16" Dia.Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL,1688 5155 4283 83.3 83.1 13855 3325 3724 16" Dia.PG, PL, and PGL and suffix WF and SF.1788 5494 4570 83.3 83.1 14784 3548 3974 18" Dia.Power Burner, Forced Draft, Inter. Ign., Natural Gas1888 5845 4857 83.3 83.1 15712 3771 4223 18" Dia.Ratings based on 9.5% CO2 and +0.10" water draft at the vent.894 2527 2028 81.2 80.3 6563 1575 1763 14" Dia.Also approved with prefix BG, BLG, ABG, ABGL,PG, PGL, and suffis WF and SF994 2887 2320 81.2 80.3 7504 1801 2017 14" Dia.1094 3247 2612 81.3 80.3 8450 2028 2271 16" Dia.88 Series 2 Oil1194 3608 2904 81.4 80.3 9396 2255 2525 16" Dia.Power Burner, Forced Draft, Light Oil 1294 3969 3190 81.4 80.3 10321 2477 2774 16" Dia.488R 6.9 827 87.5 85.6 2585 620 719 10" Dia. 1394 4330 3480 81.4 80.4 11258 2702 3026 18" Dia.488 7.0 839 87.5 85.6 2623 629 730 10" Dia. 1494 4691 3770 81.4 80.4 12196 2927 3278 18" Dia.588 9.4 1126 87.0 85.6 3520 845 979 10" Dia. 1594 5052 4070 81.5 80.4 13167 3160 3539 18" Dia.688 11.8 1413 86.7 85.6 4467 1072 1229 10" Dia. 1694 5412 4360 81.5 80.4 14104 3385 3791 18" Dia.788 14.2 1700 86.5 85.6 5463 1311 1478 12" Dia. 1794 5773 4650 81.5 80.4 15042 3610 4043 20" Dia.888 16.6 1987 86.3 85.6 6428 1543 1728 12" Dia. 1894 6134 4940 81.5 80.5 15979 3835 4296 20" Dia.988R 17.2 2062 86.2 85.6 6671 1601 1793 14" Dia. 1994 6495 5230 81.5 80.5 16921 4061 4548 20" Dia.988 19.0 2274 86.2 85.6 7356 1766 1977 14" Dia. 2094 6856 5520 81.5 80.5 17858 4286 4800 20" Dia.1088R 20.0 2399 86.2 85.6 7761 1863 2086 14" Dia. 2194 7216 5810 81.5 80.5 18796 4511 5052 20" Dia.1088 21.4 2561 86.2 85.6 8285 1988 2227 14" Dia. 2294 7649 6100 81.5 80.5 19733 4736 5304 22" Dia.1188 23.8 2848 86.1 85.7 9213 2211 2477 14" Dia. 2394 7938 6390 81.5 80.5 20671 4961 5557 22" Dia.1288 26.2 3135 86.0 85.7 10142 2434 2726 14" Dia. 2494 8371 6680 81.5 80.5 21608 5186 5809 22" Dia.1388 28.6 3422 86.0 85.7 11070 2657 2976 14" Dia. 2594 8660 6970 81.5 80.5 22546 5411 6061 22" Dia.1488 31.0 3709 86.0 85.7 11999 2880 3225 16" Dia. Ratings based on 9.5% CO2 and +0.10" water draft at the vent.1588 33.4 3996 85.9 85.7 12927 3102 3475 16" Dia. Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL,1688R 34.6 4137 85.9 85.7 13383 3212 3597 16" Dia. PG, PL, and PGL and suffix WF and SF.1688 35.8 4283 85.9 85.7 13855 3325 3724 16" Dia.APR 2009 - 53# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


BoilerModelNameplateInputGas(MBh)Oil(gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)COMMERCIAL BOILERSVentSize(LxWxH)#EGH Series 4Atmospheric, Standing Pilot, Natural or Propane GasEGH-85 350 280 80.0 75.6 875 210 243EGH-95 400 320 80.0 75.7 1000 240 278EGH-105 450 360 80.0 75.8 1125 270 313EGH-115-PIN 500 400 80.0 75.9 1250 300 348EGH-125-PIN 550 440 80.0 76.0 1375 330 383#LGB Series 2Atmospheric, Standing Pilot, Natural or Propane GasLGB-4 400 324 81.0 78.0 1013 243 282LGB-5 520 422 81.0 78.7 1317 316 366LGB-6 650 527 81.0 79.1 1645 395 458LGB-7 780 632 81.0 79.4 1975 474 549LGB-8 910 738 81.0 79.6 2305 553 641LGB-9 1040 843 81.0 79.7 2635 632 733LGB-10 1170 948 81.0 79.8 2965 711 824LGB-11 1300 1053 81.0 79.9 3290 790 916LGB-12 1430 1159 81.0 80.0 3620 869 1007LGB-13 1560 1264 81.0 79.4 3955 949 1099LGB-14 1690 1369 81.0 79.5 4315 1035 1190LGB-15 1820 1475 81.0 79.6 4680 1123 1282LGB-16 1950 1580 81.0 79.6 5045 1211 1373LGB-17 2080 1685 81.0 79.7 5410 1298 1465LGB-18 2210 1791 81.0 79.8 5775 1386 1557LGB-19 2340 1896 81.0 79.8 6125 1470 1648LGB-20 2470 2001 81.0 79.9 6470 1553 1740LGB-21 2600 2106 81.0 79.9 6815 1635 1831LGB-22 2730 2212 81.0 80.0 7155 1717 1923LGB-23 2860 2317 81.0 80.0 7495 1799 2014#PFG Series 6Atmospheric, Inter. Ign., Natural GasPFG-6-PIN 305 247 81.0 76.8215PFG-7-PIN 366 296 81.0 78.2257Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN,SPL, N and L.Atmospheric, Inter. Ign., Natural or Propane GasPFG-8-PIN 427 346 81.0 79.1301Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN,SPL, N and L.Atmospheric, Standing Pilot, Natural or Propane GasPFG-6-SPN 305 247 81.0 76.8215PFG-7-SPN 366 296 81.0 78.2257Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN,SPL, N and L.SGO Gold Series 3BoilerModelNameplateInputGas Oil(MBh) (gph)GrossOutput(MBh)CombEffy(%)ThermalEffy(%)Net I=B=R RatingsSteam(sqft)Steam Water(MBh) (MBh)VentSize(LxWxH)WEIL-MCLAINNatural Draft, Light OilSGO-8 2.30 266 85.0 82.7 833 200 8x12x20CAST IRONSGO-8W 2.30 266 85.0 82.7231 8x12x20#EG Series 4SGO-9 2.55 295 85.0 82.7 921 221 8x12x20Atmospheric, Inter. Ign., Natural GasSGO-9W 2.55 295 85.0 82.7257 8x12x20Ratings based on 13.0% CO2 and -0.02" water draft.EG-75-PI 300 240 80.0 75.4 750 180 209Also approved with prefix P, B, or A.Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN,SPL, N and L.WGO/WTGO Gold Series 3Atmospheric, Standing Pilot, Natural or Propane GasNatural Draft, Light OilEG-75-S 300 240 80.0 75.4 750 180 209WT/WGO-8 2.30 266 85.0 82.7231 8x12x20Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, WT/WGO-9 2.55 295 85.0 82.7257 8x12x20SPL, N and L.Ratings based on 13.0% CO2 and -0.02" water draft.Damper, Atmospheric, Inter. Ign., Natural Gas Also approved with prefix P, B, or A.EG-75-PIDN 300 240 80.0 75.4 750 180 209Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN,SPL, N and L.Damper, Atmospheric, Standing Pilot, Natural or Propane GasEG-75-SPD 300 240 80.0 75.4 750 180 209Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN,SPL, N and L.APR 2009 - 54# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13


INDEXPAGE INDEX OF BOILER MANUFACTURERSRESIDENTIALCAST STAINLESS CON-IRON STEEL STEEL ALUMINUM COPPER DENSINGCOMMERCIALAerco International, Inc................................................ ................... ................... ................... ................... .................................... 36Northvale, NJAmerican Standard Heating & Cooling Products ........ 5Tyler, TXAxeman-Anderson Company ....................................... ..................5South Williamsport, PABiasi, S.p.A./QHT, Inc. ............................................... 6.................. ................... ................... ................... .................................... 36Portsmouth, NHBosch Thermotechnology Corp................................... 6.................. ................... ..................6 .................. ..................6................ 36Londonderry, NHBoyertown Furnace Co................................................ 7Boyertown, PABurnham <strong>Commercial</strong>.................................................. 7.................. ................... ................... ................... .................................... 37Lancaster, PABurnham Hydronics (U.S. Boiler Co., Inc.) ............... 7.................8 .................8 .................7 .................. ..................7................ 38Lancaster, PACamus Hydronics Ltd................................................... ................... ..................9Mississauga, ON, CanadaCarrier Corporation ..................................................... 9.................. ................... ..................9 .................. ..................9Indianapolis, INClimate Energy, LLC ................................................... ................... ................... .................10Medfield, MAColumbia Boiler Company......................................... 10...............11 ................. ................... ................... .................................... 38Pottstown, PACrown Boiler Company.............................................. 11................. ................... .................11 ...............13 ...............11............... 38Philadelphia, PADunkirk <strong>Boilers</strong>, ECR International, Inc. ................... 13................. ................... .................13 ................. .................13............... 39Utica, NYECR International…………………………………………………………………………….14Utica, NYEFM.............................................................................. .................14Schuylkill Haven, PAGenesis Boiler Co....................................................... 15North Bergen, NJHamilton Engineering…………………………………………………………...15Livonia, MIHeat Transfer Products, Inc. ......................................... ................... .................16 ................. ................... .................16............... 39East Freetown, MAAPR 2009 - 92


INDEXPAGE INDEX OF BOILER MANUFACTURERS (cont.)RESIDENTIALCAST STAINLESS CON-IRON STEEL STEEL ALUMINUM COPPER DENSINGHydrotherm, Div. of Mestek ...................................... 16................. ................... ................... ................... .................16.................Westfield, MAInternational Comfort Products Corp. (USA) ............. 16(Arcoair, Clare, Comfort Maker, Heil, Tempstar)Lewisburg, TNAPR 2009 - 93COMMERCIALLaars Heating Systems Company................................. .................18 ................. ................... .................17 ...............17............... 40Rochester, NHLennox Industries, Inc. ............................................... 18................. ................... .................18 ................. .................18Carrollton, TXLochinvar Corporation ................................................. ................... .................19 ................. .................19 ...............19............... 40Lebanon, TNMestek, Inc ................................................................. 20Westfield, MANew Yorker Boiler Company..................................... 20...............21 ................. ................... ................... .................................... 41Hatfield, PANY Thermal, Inc…………………………………………………………………21……………………………………21St. John, NB, CanadaPB Heat, LLC ............................................................. 21...............22 ...............22 ................. ................... .................22............... 41Bally, PAPatterson-Kelley Co./Harsco Corporation……………………………………………………………………………………………43East Stroudsburg, PAPennco, ECR International, Inc. ................................. 22................. ................... ................... ................... .................................... 43Utica, NYPNA, Inc./Pensotti ...................................................... 23Bangor, MEPurePro ....................................................................... 24Boyertown, PARaypak, Inc. ................................................................ ................... ................... ................... .................24 .................................. 44Oxnard, CARBI Water Heaters, Div. of Mestek Canada................. ................... ................... ................... .................24 .................................. 45Mississauga, ON, CanadaSears Roebuck and Company ..................................... 25................. ................... .................25 ................. .................25Chicago, ILSlant/Fin Corporation ................................................. 25................. ................... .................25 ................. .................25............... 46Greenvale, NYSmith Cast Iron <strong>Boilers</strong>, Div. of Westcast, Inc........... 27................. ................... ................... ................... .................................... 48Westfield, MAA.O. Smith Water Products Co. ................................... ................... ................... ................... ................... .................................... 50Irving, TX


INDEXPAGE INDEX OF BOILER MANUFACTURERS (cont.)RESIDENTIALCAST STAINLESS CON-IRON STEEL STEEL ALUMINUM COPPER DENSINGCOMMERCIALThermal Solutions Products, LLC ................................ ................... ................... ................... ................... .................................... 51Lancaster, PAThermo-Dynamics Boiler Co. ...................................... .................29 ................. ................... ................... .................................... 51Schuylkill Haven, PATrane Products............................................................ 30Tyler, TXTriangle <strong>Tube</strong> ............................................................... ................... .................30 ................. ................... .................30............... 51Blackwood, NJUltimate Engineering, ECR International, Inc. .......... 30Utica, NYUtica <strong>Boilers</strong>, ECR International, Inc......................... 30................. ................... .................30 ................. .................30............... 51Utica, NYUtica Heating.............................................................. 31Utica, NYViessmann Manufacturing Co.. .................................. 31...............32 ...............32 ................. ................... .................32............... 52Waterloo, ON, CanadaWeil-McLain .............................................................. 32................. ................... .................32 ................. .................32............... 52Michigan City, INWilliamson Thermoflo................................................ 34Milwaukee, WIAPR 2009 - 94


INDEXPAGE INDEX OF BASEBOARD AND FINNED TUBE MANUFACTURERSBASEBOARDFINNED TUBEAiredale • Racine, WI.......................................................................................................... ............................................................ 67Argo Technology, Inc. • Westfield, MA............................................................................ 56Burnham Hydronics (U.S. Boiler Co., Inc.) • Lancaster, PA............................................. 56Crown Boiler Company • Philadelphia, PA....................................................................... 56Design Line, Div. of Mestek, Inc. • Westfield, MA .......................................................... 56Embassy Industries Inc. • Westfield, MA.......................................................................... 56Governale Company, Inc. • Brooklyn, NY........................................................................ 57Haydon Corporation, Thermogenics Div. • Paterson, NJ .................................................. 57Hydrotherm, Div. Mestek, Inc. • Westfield, MA............................................................... 59Modine Manufacturing Co. • Racine, WI ............................................................................ ............................................................ 67OCS Industries, Div. of CIDC Corp. • Brooklyn, NY ....................................................... 59Rittling, A Division of Hydro-Air Components, Inc. • Buffalo, NY ................................. ............................................................ 68Rosemex, Inc. • St-Bruno, PQ, CANADA .......................................................................... ............................................................ 69Sigma Convector Enclosure Corp. • Brampton, ON, Canada.............................................. ............................................................ 69Slant/Fin Corporation • Greenvale, NY............................................................................. 59.......................................................... 69Sterling Hydronics, Div of Mestek, Inc. • Westfield, MA................................................. 60.......................................................... 70Suntemp, Div. of Mestek, Inc. • Westfield, MA................................................................ 62The Trane Company • LaCrosse, WI................................................................................... ............................................................ 71Vulcan Radiator, Div. of Mestek, Inc. • South Windsor, CT............................................... ............................................................ 73Weil-McLain • Michigan City, IN..................................................................................... 62PAGE INDEX OF INDIRECT- FIRED WATER HEATER MANUFACTURERSBock Water Heaters • Madison, WI................................................................................................................................................. 79Bradford White Corp. • Ambler, PA,................................................................................................................................................ 79Burnham Hydronics (U.S. Boiler Co., Inc.) • Lancaster, PA............................................................................................................ 79Crown Boiler Company • Philadelphia, PA...................................................................................................................................... 79Heat Transfer Products, Inc • East Freetown, MA............................................................................................................................ 80Laars Heating Systems Company. • Rochester, NH ......................................................................................................................... 80Lochinvar Corp. • Lebanon, TN ....................................................................................................................................................... 80PB Heat, LLC. • Bally, PA ............................................................................................................................................................... 81Vaughn Manufacturing Corp. • Salisbury, MA ................................................................................................................................ 81TABLESTable I - I=B=R Water Ratings ....................................................................................................................................................... 82Table J - Flat Top Cover Steam Ratings.......................................................................................................................................... 88Table K - Expanded Metal Cover Steam Ratings............................................................................................................................. 90APR 2009 - 95