12.07.2015 Views

Series 90-70 Genius Bus Controller Manual, GFK-2017

Series 90-70 Genius Bus Controller Manual, GFK-2017

Series 90-70 Genius Bus Controller Manual, GFK-2017

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1System OverviewThe <strong>Genius</strong> <strong>Bus</strong> <strong>Controller</strong> (catalog number IC697BEM731) can be used to interface aPACSystems RX7i controller or <strong>Series</strong> <strong>90</strong>-<strong>70</strong> PLC to a broad range of other devices ona <strong>Genius</strong> I/O serial bus.RX7i or <strong>Series</strong> <strong>90</strong>-<strong>70</strong> PLCwith <strong>Genius</strong> <strong>Bus</strong> <strong>Controller</strong>Host Computer<strong>Series</strong> <strong>90</strong>-30 PLC withbus controller module<strong>Series</strong> <strong>90</strong>-30 PLC withcommunications modulePCIM<strong>Genius</strong> <strong>Bus</strong><strong>Genius</strong>BIU<strong>Genius</strong> I/O Blocks<strong>Genius</strong>NIU<strong>Series</strong> <strong>90</strong>-<strong>70</strong> Remote I/O Dropwith Remote I/O ScannerVersaMax I/O StationField Control I/O StationA <strong>Genius</strong> bus may serve:▪ Individual <strong>Genius</strong> I/O Blocks. <strong>Genius</strong> blocks are self-contained discrete, analog,and special-purpose modules with advanced diagnostics capabilities and manysoftware-configurable features.▪ Other PLCs: RX7i, <strong>Series</strong> <strong>90</strong>-<strong>70</strong>, <strong>Series</strong> <strong>90</strong>-30. <strong>Series</strong> Six and <strong>Series</strong> Five PLCscan also be connected to the <strong>Genius</strong> bus.▪ <strong>Series</strong> <strong>90</strong>-<strong>70</strong> Remote Drops. A remote drop is a <strong>Series</strong> <strong>90</strong>-<strong>70</strong> rack that isinterfaced to the bus by a Remote I/O Scanner module. Each remote drop canexchange up to 128 bytes of input data and 128 bytes of output data.▪ VersaMax and Field Control I/O Stations. An I/O Station consists of a group ofI/O and special-purpose modules connected to the bus via an interface module.Each remote drop can exchange up to 128 bytes of input data and 128 bytes ofoutput data.▪ Multiple hosts, for communications using datagrams and Global Data.A bus may be used entirely for I/O control, or it may feature I/O control enhanced bycommunications commands in the program. A bus may also be dedicated to CPUcommunications, with multiple CPUs and no I/O devices. More complex systems canalso be developed, with dual CPUs and one or more additional CPUs for datamonitoring.Number of <strong>Bus</strong> <strong>Controller</strong>s in a PLCUp to 31 <strong>Bus</strong> <strong>Controller</strong>s can be included in the RX71 or <strong>Series</strong> <strong>90</strong>-<strong>70</strong> rack system. Insome redundant systems, fewer <strong>Bus</strong> <strong>Controller</strong>s are possible. See chapter 7 fordetails.<strong>GFK</strong>-<strong>2017</strong> Chapter 1 Introduction 1-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!