PremsetMedium Voltage DistributionCompact Modular Vacuum SwitchgearShielded Solid Insulation SystemInnovation forMV distributionIntroducing Premset switchgear,a new way to design, install,and operate MV networksJanuary 2012Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 1


Index - Indoor versionIndex A new generation of switchgeartechnologyPremset Where is Premsetimplemented? Key Benefits Range offer descriptionand technical featuresRange KeyWhere?BenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 2


The new generationPremsetin switchgear technologySchneider Electric – Infrastructure Business – MV Premset presentation – January 20123


Taking advantage of the experienceThe new generationof switchgear technology SM6 + Fluokit + Ringmaster:1 000 000 functions installed- Modular- Versatile- Wide and comprehensive offer RM6 + FBX + RN2C:2 500 000 functions installed- Compact solution for Utilities MVdistribution, ready-to-connect- Insensitive to harsh environments or badconditions of installation- Minimum maintenance- Extensible for network evolutionPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 4


Innovative architecture designedwith your needs in mindThe new generationof switchgear technology-“ you have to take in account the smart grid trend ”-“ expected life duration of switchgear is increasing ”-“ maintenance-free is far more important than SF6-free”-“ maintenance and operation teams know-how is decreasing ”-“ cost effective and compact Circuit Breakers are neededfor small primary substations or loop management ”-“ no problems with GIS switchgear, because reliable in harshenvironment (humidity, temperature, dust, poor installation, partialdischarges) ”-“ I’ll never compromise about end-users safety ”PremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 5


Premset: a technological breakthrough, opening the wayto unprecedented safety, efficiency, and ease of useThe new generationof switchgear technology Like Air Insulated Switchgear- Modular- Versatile- Comprehensive Like Gas Insulated switchgear- Compact- Easy to install- Severe environment robust- Minimized maintenancePremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 6


Premset: a technological breakthrough, opening the wayto unprecedented safety, efficiency, and ease of useThe new generationof switchgear technology Premset:Shielded Solid Insulation System (2SIS)- Safe and reliable in any environment- Flexible, simple, modular, and functional- Smart grid-ready, distributed intelligencePremsetPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 7


Premset: GIS+AIS = 2SIS*:Shielded Solid Insulation SystemThe new generationof switchgear technology It is a new concept, aiming to achievethe highest level of reliability,safety and advanced powermanagement solutions foryour MV network Premset offer target is to take advantagesof both technologies GIS andAIS, in creating Modular, SevereEnvironment Insensitiveswitchgear, using SF6-free technologiesand Flexible / ready forSmart Grids* Gas Insulated Switchgear + Air InsulatedSwitchgear = Shielded and Solid InsulationSystem (2SIS)PremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 8


Premset: modular 2SIS technologyThe new generationof switchgear technologyPremsetPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 9


Premset: a disruptive technological breakthroughopening to a new generation of switchgearThe new generationof switchgear technology EfficiencySmart grid and advanced managementsolutions across the network ReliabilityLong-lasting performance with the ShieldedSolid Insulation System (2SIS) SafetyAn intuitive 3-in-1 architecture for breaking,disconnection, and earthing FlexibilityA compact and modular design for allfunctionsPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 10


Premset: a disruptive technological breakthroughopening to a new generation of switchgear - ReliabilityThe new generationof switchgear technology Long-lasting performance withShielded Solid Insulation System(2SIS)- Extending protection to the entireswitchgear assembly, in any harshenvironment- Enhanced safety, reduced internalarcing risk- Longer life expectancy, gas-free 2SIS is applicable for any functionsuch as:- Load break switches or circuit breakers- New compact metering functions- Current and Voltage transformersPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 12


Premset: a disruptive technological breakthroughopening to a new generation of switchgear - SafetyThe new generationof switchgear technology An intuitive 3-in-1 architecture forbreaking, disconnection, and earthing Simple and user-friendly scheme Intuitive operation, reducing riskfor user The safest MV switchgearin its classPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 13


Premset: a disruptive technological breakthroughopening to a new generation of switchgear - FlexibilityThe new generationof switchgear technology A compact and modular design for all functions- Fast, stress-free installation, upgrading, and maintenance Modular combination and optimized circuit breakers- Straightforward assembly with identical busbar and cableconnections for the entire range- Easy-to-install patented universal flat power connection system- Easy cabling since all cable connections are at a heightof 700 mm- Extended possibilities of cable entry management- No preventive maintenance and servicing requiredPremsetSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 14


Where isPremsetimplemented?Where?Schneider Electric – Infrastructure Business – MV Premset presentation – January 201215


Field of applications Buildings Industry Buildings Energy Industry EnergyWhere?Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 16


Applications targetedEnergy Primary substation (> 20 MVA)Buildings, Industry, MMM, O&G Heavy industry primary substation (> 20 MVA)Where? Large switching substation (< 4 MVA) Large MV consumers site (5 – 10 MVA) MV/LV substations (< 2 MVA) MV consumer site (1 – 5 MVA)Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 17


Applications targetedEnergy Primary substation (> 20 MVA)Buildings, Industry, MMM, O&G Heavy industry primary substation (> 20 MVA)132kV/11kV Busbar > 2000A Large switching substation (< 4 MVA)132kV/11kV, 10-50MVA, Busbar < 3150A, draw outPetrochemical, Automotive, Steel & Cement plants, Paper mills Large MV consumers site (5 – 10 MVA)Where?630-1250A, fixed, pilot protections MV/LV substations (< 2 MVA)630A-1250A, fixed, pilot protectionsHospitals, Universities, Regional airports, Food & Beverage factories, …. MV consumer site (1 – 5 MVA)630A Ring Main Unit - Kiosks or Buildings630A, Kiosks or BuildingsShopping center, light manufacturing, retail or industrial park, ….Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 18


Applications targetedEnergy Primary substation (> 20 MVA)Buildings, Industry, MMM, O&G Heavy industry primary substation (> 20 MVA)132kV/11kV Busbar > 2000A Large switching substation (< 4 MVA)132kV/11kV, 10-50MVA, Busbar < 3150A, draw outPetrochemical, Automotive, Steel & Cement plants, Paper mills Large MV consumers site (5 – 10 MVA)Where?630-1250A, fixed, pilot protections MV/LV substations (< 2 MVA)630A-1250A, fixed, pilot protectionsHospitals, Universities, Regional airports, Food & Beverage factories, …. MV consumer site (1 – 5 MVA)630A Ring Main Unit - Kiosks or Buildings630A, Kiosks or BuildingsShopping center, light manufacturing, retail or industrial park, ….Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 19


Typical applicationsBuildingWhere is Premsetimplemented?IndustryEnergy2.25m3.75 m3.75 mWhere?Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 20


Typical application for Building -Compact MV consumer substation with MV meteringWhere is Premsetimplemented?2.25 mWhere?Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 21


Other applicationsTaking opportunity of Premset assets…Where is Premsetimplemented? SF6-free RMU package offer for Energy :from 2 to 5 functional units (any order) packaged in single unit,ready to install Harsh environment withstand Marine, Watertreatment, Mining … Modular and consistent system Infrastructures,Light industry applications Embedded solutions in Control & Monitoring Data centers,Hospitals Outdoor rural outdoor substations, including simpleprimary substations (overhead substitution)Where?Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 22


Specific typesRing Main Unit versionOutdoor versionWhere is PremsetimplementedWhere?Schneider Electric – Infrastructure Business – MV Premset presentation – January 2012 23


KeybenefitsKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 24


Voice of Customers - Selected examples (reminder)-“ you have to take in account the smart grid trend ”-“ expected life duration of switchgear is increasing ”-“ maintenance-free is far more important than SF6-free”-“ maintenance and operation teams know-how is decreasing ”Premsetkey benefits-“ cost effective and compact Circuit Breakers are neededfor small primary substations or loop management ”-“ no problems with GIS switchgear, because reliable in harshenvironment (humidity, temperature, dust, poor installation, partialdischarges) ”-“ I’ll never compromise about end-users safety ”KeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 26


FlexibleA compact and modular design for all functions Easy to upgrade- Modularity, “plug & play” design- Same auxiliaries, accessories, and monitoring devices being used forthe entire range- Self-addressing Intelligent Electronic Devices- Last minute modification of auxiliaries & accessories, without any tool orspecific trainingPremsetkey benefits Easy end of life- No hazardous emission : SF6-free, RoHS compliant…- No care of future SF6 regulation : SF6-free. Can be installed in any public areaor building- Innovative design for increased environmental impacts controlUp to 30%The increase in life expectancy due to the absenceof pressurized gasesKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 30


EfficiencySmart grid and advanced management solutions across the network Advanced and integrated protection, network control andmonitoring features- Self-powered or dual-power VIP protection relay range- Integrated compact solutions for power measurement and power metering Smart grid-ready- Feeder automation- Load management- Asset management- Automated Metering ManagementPremsetkey benefits Thanks to distributed intelligence- Flexible approach- Distributed intelligence- Embedded intelligence- Integrated in solutions- Web technologyKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 31


Total Cost of Ownership optimization Longer life expectancy- Insensitive to harsh environment (dust, pollution, humidity) and uncontrolledinstallation conditions : solid and screened design, no partial discharge issues- Gas-free, no over-pressure True maintenance free- No maintenance, nor servicing required. Entire system is solid and shielded : no electrical field in open air. No gas, so no gas monitoring. Sealed for life system, servicing-free mechanismPremsetkey benefits Modularity- Reduced delivery times- On site last-minute modifications without tools or training Reduction of time and money spent during the installation- Uniform dimensions- Reduced footprint- Simple front power connections- Modification of auxiliaries & accessories, without any tool or specific training Wide and consistent range of optimized-to-application corefunctions- 2 types of loading switches (I06T, I06H)- 4 types of Circuit-Breakers (D01N, D02N, D06N, D06H)- 3 types of power measurement/metering ( M06S, M06A, integrated)KeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 32


Totally Shielded Solid Insulation System design foroptimized safety and extended equipment life1231 – Low Voltage cabinet2- Cable testPremsetkey benefitsSafety & Reliability875643- Top connections4 – Core unit5 – Bottom connections6 – Bottom compartment7 – Sensors (CTs and VTs)8 – Gas exhaust ductKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 33


Totally Shielded Solid Insulation System design foroptimized safety and extended equipment lifePatented flat connecticsBusbars with shielded solid insulationPremsetkey benefitsSafety & ReliabilitySingle bus bar (630A)Cable connectionKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 34


3-in-1 integrated architecture: easiest and safest operation,with built-in interlockingPremsetkey benefitsSafety & Reliability“The most intuitive operations for breaking, disconnection andearthing”KeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 35


3-in-1 integrated architecture: easiest and safest operation,with built-in interlockingPremsetkey benefitsSafety & Reliability“The most intuitive operations for breaking, disconnection andearthing”KeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 36


Disconnection in vacuum & earthing switchin controlled air redundancy of isolation- vacuum bottles for breakingand disconnection- controlled air for downstreamearthing switch in sealed-for-life screened tank.Breaking anddisconnectionEarthingswitchPremsetkey benefitsSafetyOperationof earthingswitchOperationof mainswitchKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 37


Disconnection in vacuum & earthing switchin controlled airPremsetkey benefitsSafetyKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 38


"Universal" connecting system Cable connections are made with a single design andcable clamping, with limited number of components Cable connections and clamping allowing- Any cable configuration : bottom-front, top-rear, cable in – cable out…- Last-minute differentiation of measurement CTs, front locatedPremsetkey benefitsSimplicityFront connection - Bottom inRear connection Top outRear connection Top inKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 39


Cable testing and diagnosis: dedicated device,for easy access and total safety Cable testing without accessingcable box or dismantling cableconnections Test device connection from thefront of the switchboard, while cablesremain earthed Failsafe interlocks with earthed starpointPremsetkey benefitsSafetyEasy cablingAll cablesconnections arealigned in frontat a height of 700 mmKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 40


Cable testing and diagnosis: dedicated device,for easy access and total safetyPremsetkey benefitsSafetyKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 41


Live cable interlockElectrical lock-out of earthing switch when live cables Earthing switch lock-out function- Prevent the earthing switch to be closedon earth when cables are still alive- Positively blocked in case of auxiliary power loss- Override unlocking by key- Remote indication of locked positionPremsetkey benefitsSafetyKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 42


Ready for feeder automationEnsuring optimized efficiency across MV networkState-of-the-art Smart Grid andadvanced management solutions Switchgear ready for communication- Communicating FPI- Smart switchgear controller- Communicating protectionPremsetkey benefitsSmart grid-ready Remote communication withDistributed Management System- Remote alarming- Remote control Local automatism-Recloser- Self healing medium voltage ring- Source transferKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 43


Ready for load managementArchitecture with distributed intelligence Integrated smart metering- Power meter- Optimized metering cubicle- Low power sensors Remote communication toload flow management solutionPremsetkey benefitsSmart grid-readyKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 44


Ready for asset management Monitoring of switchgear- Over current and breaking profile- Backup power supply monitoring- Motorization monitoringPremsetkey benefitsSmart grid-ready Monitoring of transformer- Load- Temperature- Trends and alarming- Ageing monitoring Maintenance- Protection chain test- Remote alarming by mail, SMS,…- Type stamped events recorded Easy diagnostic on local web pagesKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 45


Ready for Automated Metering Management (AMM) LV smart meter reading- Concentration of LV smart meters- Power line carrier interface- Connection to billing systemLV network monitoring- Phases unbalance- Lack of voltage on one phasePremsetkey benefitsSmart grid-ready Detect technical and non technicallossesLocalnetworkKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 46


Flexible approach Today: set of products to connect- Protections: Sepam- Measurement metering: Power Logic- Local fault monitoring & Remote control: EasergyPremsetkey benefitsSmart grid-readyEasergySepamPower LogicKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 47


Easy to implement monitoring & control Easy installation, configuration and exploitation- Modular and plug and play architecture with serial communication- Built in web page showing single line diagram for monitoring & controlPremsetkey benefitsSmart grid-readyKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 48


Embedded intelligence in switchgear Functional approach based onoptional and independent modulesto cover various combination- Protection, Control, Measurement …Premsetkey benefitsSmart grid-ready Modules fully integrated in functionalunit- Including sensors, switchgear interface, powersupply, communication, HMI- Pre- engineered, factory-tested, cost effective- Easy integration based on :. Field bus communication between modules. Pre-cabling inside cubicle- Gradual solution : from local control up to complexfeeder automationKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 49


Integrated in Schneider Electric solutions SCADA or EMS for feederautomation with standard protocols(through R200, T200) Energy monitoring, energymanagement, building managementPremsetkey benefitsSmart grid-ready MV Loop automation solution IEC61850 access to Substationautomation through gateway (G3200…)ModbusKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 50


Low cost Supervision & Control system Switchboard information is stored in a Web page Need just a PC with a standard Web browser-Premsetkey benefitsSmart grid-readyExample of web accessKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 51


Functional system oriented design: configurable,type tested, made by Schneider Electric Optimized system of functional bricks “Type-tested" switchgear assembly Optimized interfaces between bricksPremsetkey benefitsSimplicityKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 52


A new approach for MV switchgear functional conceptPremsetkey benefitsSimplicityI06 TI06 TD06 ND02 N“Improving functionality with an advanced compactand modular design”D02 NKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 53


A new approach for MV switchgear assembly of functional bricksLV cabinetCable testTop connectionSwitchingdevicePremsetkey benefitsSimplicityI06 TI06 TD06 NM06 SD02 ND02 NBottomconnectionsBottomcompartmentKeyBenefitsSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 54


Range offerdescriptionand technical featuresRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 201255


A consistent architectureRange offer descriptionand technical features Same dimensions for all Premsetfunctional units- Width, same pitch = 375mm,- Depth = 900 / 1100mm (IAC)- Height = 1350 / 1950mm- Front aligned connections, height = 700mm Electrical characteristics- Ur: 12 kV & 15 kV- Fr: 50/60 Hz- Ud: 42-48 kV- Up: 95-110 kV Internal arc- Standard design is virtually arc free,- Optional: type tested 21KA 1s A-FLR,top or bottom exhaust Protection index; indoor version-IP3XRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 56


Premset, architecture and components Unsurpassed safety and reliabilitywith 2SIS Solid and ShieldedInsulation System1Range offer descriptionand technical features- Modular busbar system with shielded solidinsulation (1)- Vacuum bottles with shielded solid insulationfor breaking and disconnection (2)- Integrated air-insulated earthing switch enclosedin tank with shielded solid insulation (3)- Built-in voltage and current sensors for optimisedprotection and control, available in versions withshielded solid insulation where required (4)- Front aligned cable connections with shieldedsolid insulation, designed for easy clamping (5)24435RangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 57


Premset, architecture and components1Range offer descriptionand technical features Unsurpassed simplicity with mixand-matchmodular architecture basedon functional blocks- Low Voltage cabinet (different heights) (1)- Cable test (2)- Top connections (3)- Core unit (different types) (4)- Bottom connections (5)- Bottom compartment (different heights anddepths) (6)- Sensors (CTs and VTs) (7)- Gas exhaust duct (8)8375462RangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 58


Technical performances, dedicated applicationsRange offer descriptionand technical featuresTypicalapplicationI06 TDisconnectingswitchD01 N - D02 NTransformerprotectionD 06 NGeneralprotectionD 06 HLineprotectionIn 630 A 100 - 200 A 630 A 630 AIk x tkEnduranceclassTestingsequenceEnduranceIscTotal clearing,With VIP relay20 kA x 4s21 kA x 3 s25 kA x 2 s1 000 op.(M1, E3)20 kA x 4s21 kA x 3 s25 kA x 2 s2 000 op.(M1, E2)20 kA x 4s21 kA x 3 s25 kA x 2 s2 000 op.(M1, E2)20 kA x 4s21 kA x 3 s25 kA x 2 s10 000 op.(M2, E2)na O - 15 s - CO O - 15 s - CO O -0.3 s -CO-15 s - CO5 5 5 > 50na < 60 ms < 100 ms < 100 msRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 61


3 mechanisms, 1 design platform:same operation, same auxiliariesRange offer descriptionand technical featuresCITfor I06 TCI1for D01 N, D02 ND06 NOCOfor D06 H, I06 HRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 62


Flexible Metering unit optionsRange offer descriptionand technical features Conventional tariff metering M06 A- Air insulated IP54 degree of protection- 750mm wide (double pitch)- Traditional cast resin CTs and VTs- Easy to adapt to local requirements Compact metering unit M06 S- Screened VTs accessible from the front- Toroidal CTs over screened busbar- Compact size: 375mm wide (single pitch)- Harsh environment withstand Integrated in circuit breaker panel- Screened VTs in bottom compartment- Toroidal metering CTs in cable box- No extra width required in switchboard- Harsh environment withstandRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 63


Current Transformers integrated in main functionsRange offer descriptionand technical features(1) Current transformers locatedunder the core unit- Dedicated current transformer for VIP integratedself-powered protection (CuaCUb)- Low power current transformer for Sepam orany conventional relay (TLPU1)-1 A ring-type current transformer for Sepam orany conventional relay (ARU2).(2) Current transformers locatedaround bushings- Zero sequence current transformer for VIP highsensitivity earth fault protection (CSHU)- Measurement current transformer for faultpassageindication and power measurement (ARU1).(3) Current transformers locatedaround cables- Ring-type current transformer for powermeasurement or metering (ARC6 and ARC7)- Earth fault toroidal current transformer for highsensitivity earth fault protection (CSH120/200).156423RangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 64


Voltage Transformers integrated in main functions(4) Low Power Voltage Transformerslocated under the core unit or inthe busbar system (5)5Range offer descriptionand technical features- Low Power Voltage Transformer for protectionor measurement (VLPU1)(6) Voltage transformers locatedbehind the cables- Phase-to-earth voltage transformers (VRT4).16423RangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 65


Wide range of protection relay choicesRange offer descriptionand technical features VIP, performance optimized forPremset- Self powered- Optimized for Premset- Specific CT, Mitop actuator- Simple protection, easy to implement- Perfectly adapted to dedicated application Sepam & MiCOM digital relayranges: open protection & monitoring- External power- Open range- Standard CT, shunt trip actuation- From basic to sophisticated protection- Existing catalogVIP 40. MV/LV transformerprotection. Dedicated to D02. Low costEasiest setting. Fuse killer!Sepam10. MV feeder protection. CommunicationsVIP 400. Feeder protection. Overcurrent. Earth fault. Sensitive earth fault. CommunicationsSepam20, 40, 80. Advanced protection,monitoring, communicationRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 66


VIP self-powered protection relay for higherMV network availabilityRange offer descriptionand technical features VIP relays are self-powered while traditional relays requirean auxiliary power supply Self-powered protection relays increasethe availability of the MV networkand are perfectly suited to most applications- Insensitive to voltage drop due to faults- Not dependent on UPS systems (weak point of electrical installations)- Less dependent on the external environment (EMC, LV overvoltages) because they requireno external connections In addition, the VIP offers optimized performancesdue to integrated protection chain- Complete and pre-tested protection system: special CT and Mitop actuator savings on spaceand cabling time- Fast clearing time in case of transformer short-circuit (‹ 60 ms): no fuse needed- High sensitivity sensorsRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 67


Panorama of protection functions / selection tableVIP seriesIntegrated self-powered protectionoptimised for PremsetSepam seriesGeneralRange offer descriptionand technical featuresProtection functionsPhase overcurrent(ANSI 50-51)TransformerprotectionGeneral useprotectionVIP 40 VIP 45 VIP 400 VIP 410 Sepam 20 Sepam 40 Earth fault (ANSI 50N-51N) Standard (sum of current method) High sensitivity (earth fault CTs) Thermal overload (ANSI 49) Cold load pick-up Other protection functions Measurement functionsPhase and earth currents Phase peak demand current Load history Cumulative time RangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 68


Panorama of protection functions / selection tableVIP seriesIntegrated self-powered protectionoptimised for PremsetSepam seriesGeneralRange offer descriptionand technical featuresControl and monitoring functionsTransformerprotectionGeneral useprotectionVIP 40 VIP 45 VIP 400 VIP 410 Sepam 20 Sepam 40Trip indication Local (with origin of the fault) Remote (one contact) Output relays Top circuit supervision (ANSI 74TC) Time-tagged events Local on display (5 last trips) Remote via communication External tripping input Overcurrent and breakingprofileNumber of phase and earth trips Serial communication port Modbus RS485 Digital inputs/outputs forcontrol functionsPower supplyType of supply Self-powered or auxiliary self self self dual auxiliary auxiliaryMinimum load current to activatethe VIP5A 5A 7A 7ARangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 69


Protection, monitoring and controlTest operation for VIP relaysRange offer descriptionand technical features Primary injection testA primary injection circuit may be permanently installed (option)through the CTs, inside the cubicle, to test the physical integrityof the complete protection system including the CTs- The test is carried out without disconnectingthe CTs and the VIP relay displays the injected current during testing- If necessary, a temporary VIP test mode can be activated to testthe tripping of the circuit breaker by pressing a test pushbutton1 231. VIP2. Pocket Battery3. Injection test caseTest withthe PocketBattery moduleThis accessory can beconnected on the VIPrelay front plate toenergize the relay tocarry out a quick testeven though the relayis not powered.The temporary testmode can be activatedwith the keypad to testthe circuit breakerRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 70


Protection, monitoring and controlEmbedded fault passage indicator (FPI)Range offer descriptionand technical features Stand alone FPI- Fault passage detection- Local indication: Led + external lamp- Remote indication: Dry contact- Current, peak demand : local Communicating FPI- Fault passage detection- Local indication: Led + external lamp- Remote indication: Communication- Current, peak demand: local & remote- Voltage relay for ATS & ESW lockFlair 21DFlair 23DM-V. 12-48V power supply. 16 h indication. Communication portVoltage relayFlair 22D. Self power . Battery. 4 h indication . 16 h indicationFlair 21DFlair 22DRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 71


Protection, monitoring and controlEmbedded fault passage indicator (FPI) / selection tableFLAIRFLAIR 21D FLAIR 22D FLAIR 23DMRange offer descriptionand technical featuresPower supply Self-powered Dual-powered Detection Overcurrent Earth-fault Display (4 digit LCD) Ammeter Maximeter Options SCADA interface (relay) External lamp External reset Extended setting (keypad) Communication 2-volatge output relays Serial communication portRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 72


Protection, monitoring and controlMonitoring and ControlRange offer descriptionand technical features Remote Terminal Unit R200- Substation interface with SCADA through:. Local Area Network : Ethernet (industrial/infrastructure). Wide Area Network : GSM, Radio, GPRS (Energy) Automatic change over-2 MV incoming- 1 MV incoming, 1 generator- 2 MV incoming and a busbar coupling Switchgear control SC100- Achieve open/close electrical orders- Switchgear Human interface- Include safe remote control Secured Power Supply PS200- Substation power supply for motorsand control & monitoring modules- Monitoring of the batteryLocal RemotePower onReady to closeMotor OKUnit readyRangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 73


Measurement Basic ammeter: Amp 21DRange offer descriptionand technical features Communicating ammeter:Amp 23D Energy Monitoring & Power Quality:PM800 & ION 8800AmpPM 850ION 8800RangeSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 74


PremsetMedium Voltage DistributionCompact Modular Vacuum SwitchgearShielded Solid Insulation SystemAppendixSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 75


Premset, architecture and componentsRange offer descriptionand technical features Unsurpassed safety and reliabilitywith 2SIS Solid and ShieldedInsulation System Shielded Solid Insulation System (2SIS)- The entire main circuit is solid insulated withepoxy or EPDM, eliminating all live parts in free air- The solid insulation is shielded, i.e. its surface isat earth potential everywhere (no electrical field infree air) Innovative single ligne diagram, newarrangement of main functions- Disconnecting load break switch or disconnectingcircuit breaker using vacuum interrupters- Earthing switch within sealed tank with air atatmospheric pressure 3-in-1 integrated core unitsAll the necessary functions: breaking, disconnectionand earthing, are embedded in a single device Consistent range of two switches and fourcircuit breakers to suit any applicationModular system architecture, simplifyinginstallation and upgradingSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 76


Functional units designationRange offer descriptionand technical featuresPremset 15I D06N BC-MsCore unit function- I: load break switch- D: Circuit-Breaker- M: metering-G: riserRating: 01 / 02 / 06Core unit type- T: tumbler mechanism (CIT lever mechanism)- N: standard performance (CI1 single latch mechanism)- H: high performance (OCO stored energy mechanism)Metering type- A: Air Insulated- S: Solid InsulatedConnections(top / left, right / bottom)B: bus barsC: cable,L: bar from leftR: bar to rightMetering embedded- Ms: solid insulated metering- Ma: air insulated meteringSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 77


Premset environment appraisal vs existing Air Insulatedand Gas Insulated typical switchgearsPremset & Environment Premset design and innovative technology (*)are allowing lower environmental impacts- Integration of functions allows downsizing components dimensions- Less materials- Optimised global weight Premset design is complying with RoHS directive Premset SF6 Free technology is making easiermaintenance process with an increased life expectancySafe and reliable in any environmentTrouble-free service life withinsulation and screening of live partsPeace of mind with SF6-freetechnologyUp to 30%The increase in life expectancy due to the absenceof pressurized gasesSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 78


Premset environment appraisal vs existing Air Insulatedand Gas Insulated typical switchgears - Average weight of main materialsPremset & EnvironmentMasse (kg)10009008007006005004003002001000Premset AIS MetalcladProduct weight 148.3 326.0 923.0Steel 73.0 154.0 732.4Copper 9.0 45.0 95.2Aluminium 10.0 10.0 10.6Epoxy Resin 34.0 52.0 60.1Autres 22.3 65.0 24.7Premset: feeder function with 630A fixed vacuum CBAIS: feeder function with 630A fixed vacuum CB in typical Air Insulated switchgearMetalclad: feeder function with 630A drawout vacuum CB in typical ‘metalclad’ switchgearSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 79


Premset environment appraisal vs existing Air Insulatedand Gas Insulated typical switchgears - Raw Material DepletionRaw Material Depletion (Y -1 )M+D+U, 20 years, 30%InPremset & Environment1.20 E-111.00 E-118.00 E-126.00 E-124.00 E-122.00 E-120.00 E+00Premset AIS MetalcladPremset: feeder function with 630A fixed vacuum CBAIS: feeder function with 630A fixed vacuum CB in typical Air Insulated switchgearMetalclad: feeder function with 630A drawout vacuum CB in typical ‘metalclad’ switchgearSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 80


Premset environment appraisal vs existing Air Insulatedand Gas Insulated typical switchgears - Energy DepletionEnergy Depletion (MJ)M+D+U, 20 years, 30%InPremset & Environment3.00 E+052.50 E+052.00 E+051.50 E+051.00 E+055.00 E+040.00 E+00Premset AIS MetalcladPremset: feeder function with 630A fixed vacuum CBAIS: feeder function with 630A fixed vacuum CB in typical Air Insulated switchgearMetalclad: feeder function with 630A drawout vacuum CB in typical ‘metalclad’ switchgearSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 81


Premset environment appraisal vs existing Air Insulatedand Gas Insulated typical switchgears - Global WarmingGlobal Warming (g ~CO2)M+D+U, 20 years, 30%InPremset & Environment1.50 E+071.00 E+075.00 E+060.00 E+00Premset AIS MetalcladPremset: feeder function with 630A fixed vacuum CBAIS: feeder function with 630A fixed vacuum CB in typical Air Insulated switchgearMetalclad: feeder function with 630A drawout vacuum CB in typical ‘metalclad’ switchgearSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 82


Innovation for MV distributionIntroducing Premset switchgear, a new way to design, install, and operate MV networksSchneider Electric – Infrastructure Business – MV Premset presentation – January 2012 83