KTC-2 (MS9)The following chart shows the setting entries:The standard values are shown here, they may however vary.ParametersParameterdesignationSymbolDescription Unit Range OriginalsettingPalmCentral systemLearning cycleOriginal settingWiringCurrent errorstatusError list - - - - -Door diameter Door diameter mm 2000 .. 6500 (systemlearnsdiameter)#el. lockingdevicesElectromechanical bolt lockingdevice no = 0, yes = 1- - C - -0 .. 1 0 U U - C -Hold after s<strong>to</strong>p#X-Pos Au<strong>to</strong>1 - 2Time until the el. brake isreleased after an EmergencyS<strong>to</strong>p0 = brake never released, 1 - 9= after... sec.Number of starting positions inAu<strong>to</strong>matic 1 or 2sec (0 .. 9) sec 1 U U - C -2 .. 5 2 U U - C -SlowS<strong>to</strong>p canopySlowS<strong>to</strong>p time of canopyintegratedsensorssec(0 .. 15) sec16 = ∞16 U U - C -SlowS<strong>to</strong>p wing SlowS<strong>to</strong>p time of wing sensor 0.1sec(0 .. 15.9) sec16.0 = ∞16.0 U U - C -Hold after s<strong>to</strong>pTime until the <strong>door</strong> starts after asafety s<strong>to</strong>p0.1sec(0 .. 9.9) sec 1.0 U U - C -Sec. area s<strong>to</strong>pSummerconfigurationStarting positionSummerDetection range of canopyintegratedsensor in securityarea for SlowS<strong>to</strong>pStarting-positions: 0°/180°Starting-positions: 90°/270° [0],60°/240° [1]mm(d * (pi/3).. 500) mm700 U U - C -(systemreads X-positions)- - - - U0 .. 1 0 U U - C -PosV after safetys<strong>to</strong>pA/M lightingTime system operates inpositioning speed after leavingthe stationary position followinga safety s<strong>to</strong>pAu<strong>to</strong>matic/<strong>manual</strong> lightingcontrol0.1sec(0.0 .. 2.9) sec 1.0 U U - C -0 ... 1 0 (au<strong>to</strong>) U U - C -FUT warm aircurtainFollow-up time of warm aircurtainsec 0 ... 600 10 U U - C -Caption:U = adjustable valueC = resettable value- = non-adjustable valueStand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 3 von 14


KTC-2 (MS9)2. Reconnect NC at OUT4 <strong>to</strong> NO at the locking module „IL1“.OLD:-Z1Stand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 4 von 14


KTC-2 (MS9)4. Change the following in the UPS moni<strong>to</strong>ring circuit:- New terminal strips –X105- Additional relay K7 (230VAC-version)Exchange the old terminal strip –X105 by the new one and install the additional relayK7. Wiring as follows:NEW “K7”Stand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 7 von 14


KTC-2 (MS9)Stand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 8 von 14


KTC-2 (MS9)5. Carry out the wiring as follows if the <strong>door</strong> system is furnished with UPS:If a UPS is joined up in circuit, put the inlet connec<strong>to</strong>r for non-heating apparatus from–X103 in<strong>to</strong> the UPS and the other 230VAC adapter cable <strong>to</strong> be connected betweenUPS and control system at –X103.Stand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 9 von 14


KTC-2 (MS9)6. Is the <strong>door</strong> system without UPS, please proceed with the wiring as follows:Stand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 10 von 14


KTC-2 (MS9)7. Re-wire the inputs in the rotating part „I1“ here IN10+11 as follows:+-Stand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 11 von 14


KTC-2 (MS9)8. Adjust the crossover cable from the MS9 control system <strong>to</strong> ES200.Connect the delivered 2-wire cable „33.1 ES200-Not Halt“ with the terminals –X101:33/34 and ES200:32/33. Remove bridge (ES200: 32-33) at ES200 beforehand.New connectionTerminal “47” is connected <strong>to</strong>+24VDCStand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 12 von 14


KTC-2 (MS9)If all changes are carried out, please put the <strong>door</strong> system back in<strong>to</strong> operation asfollows:10. <strong>In</strong>itial operation of the <strong>door</strong> system The emergency-s<strong>to</strong>p is activated The control system is switched on Program switch KT on Au<strong>to</strong>matic 1 The curved sliding <strong>door</strong> wings and the showcase <strong>door</strong>s are closed The frequency converter and the CPU are parameterized Door system is in summer position Push Select push but<strong>to</strong>n and <strong>keep</strong> it pushed for 4 sec Release emergency-s<strong>to</strong>p Learning cycle starts<strong>In</strong>dication of learning cycle and positioning driveDuring the learning cycle and positioning drive the display shows a gyro. Door system rotates in positioning speed The <strong>door</strong> system turns for min. 1 rotation Afterwards the <strong>door</strong> system restarts with its regular function Check all functions according <strong>to</strong> the original <strong>manual</strong> and/or the attached chart. Check if the control system has learned the correct diameter. Check via parameter .11. Testing of changes- Door systems with UPS: Revolving <strong>door</strong> has <strong>to</strong> rotate in program switch positionAu<strong>to</strong>1 or Au<strong>to</strong>2 in<strong>to</strong> summer position and s<strong>to</strong>p there.- Program switch position in „Summer“ and the sliding <strong>door</strong> is in operation (test allprogram switch positions of the sliding <strong>door</strong>), sliding <strong>door</strong> must s<strong>to</strong>p in case theemergency-s<strong>to</strong>p is activated and remain in this position as long as this isactivated.- Check all revolving <strong>door</strong> functions again.DoneStand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 14 von 14